Sources sought
Fluent System and RF Controller Model | Pittsburgh VAMC
36C24425Q0020
Department of Veterans Affairs, 244-Network Contract Office 4. Surgical and Medical Instrument Manufacturing.
Response deadline
November 1, 2024 at 12:00 PM EDT
Closed 756 days ago. Posted October 29, 2024. Scheduled to archive November 16, 2024.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2024
14 like it are open now in surgical and medical instrument manufacturing
- NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)
Department of Veterans Affairs, Sac Frederick
Sources soughtNAICS 339112Ship to the buyer36C10X27Q0025Due in 3 daysNov 30 - TEST KIT,MICRO SAMPLE
Defense Logistics Agency, DLA Troop Support
Combined synopsis and solicitationSDVOSBNAICS 339112Ship to the buyerSPE2DS27T2443Due in 4 daysNov 30 - COMBINED SYNOPSIS/SOLICITATION/ (Brand Name or Equ
National Institutes of Health, National Institutes of Health Olao
Combined synopsis and solicitationNAICS 339112Ship to the buyer75N98027Q00089Due in 4 daysDec 1
All 14 open in surgical and medical instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 339112 (surgical and medical instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of October 29, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The following is a Sources Sought/ Request for Information notice. This posted notice is not a Pre-Solicitation or Solicitation document. The Government is not currently soliciting bids, quotes, or proposals at this time; however, reserves the right to do so at a later date. The VA Pittsburgh Healthcare System (VAPHS), University Drive C, Bldg#1, Room 2A118, Pittsburgh PA 15240, has a Brand Name or Equal requirement for procurement item description. The following items are required: This is a Brand Name or Equal requirement for one Endometrial Ablation System and Fluent Fluid Management System.
Scope of Work: To obtain one (1) Ablation RF Controller Model 10, one (1) Fluent Fluid Management System, one (1) Myosure Device Model #10-403FC, and one (1) Fluent Disposable Pack Model #FLT-112.
Requirements: Description/Part Number* Qty RF Controller Endometrial Ablation System 1 Salient Characteristics: Continuously monitors and measures tissue impedance. Moisture Transport System powered by suction. No pretreatment required. No Cycle Dependent Impedance-Controlled Radiofrequency Ablation Mechanism No Procedural Distension Perforation Detection: Cavity Integrity System (Per-Procedure) One sterile, single patient, disposable device with connecting cord. One RF controller One foot switch One AC power cord One non-sterile suction line desiccant assembly. One CO2 canister. Description/Part Number* Qty Fluid Management System 1 Salient Characteristics:
Components Included: Fluid Bag Hooks Fluid Bag Pole Touchscreen Monitor In and Out Receptacle Tissue Removal Device Connector Foot Pedal Connector Waste Bag and Hanger Wheels and Wheel Locks Power Port Equipotential Plug Storage Basket w/ Mount Points Able to manage fluid use throughout the procedure. Advanced Pressure Control. Compatible Single-Use Disposable Tubing Sets Can be used with hypotonic, electrolyte-free media, and isotonic, electrolyte containing media.
Technical Specifications Max Load Cell Capacity: <6.3 kg for Supply and Waste Bag Hooks.
Voltage Range:
100-240 VAC Supply Frequency Range: 50-60 Hz Continuous Mode of Operation Pressure Range (mmHg): 40-120 Adjustable Deficit (mL): 100-250 Flow Measurement Range (mL/min): 0-650 Deficit Range (mL): -9999/+99999 Accuracy: Pressure (mmHg): + or 15 Flow (mL/min): + or 50 Deficit (mL): + or 50 under normal use Useful Life Expectancy: 1,000 hr.
Delivery: Delivery shall be within ninety (90) days from time of award. Systems shall be delivered to the Pittsburgh VAMC located at University Drive C. Pittsburgh, PA 15240;
Attn: Warehouse. Biomedical Engineering will need to perform a safety check and enter the equipment into the system for annual Preventive Maintenance (PM) checks. Placement in the Pittsburgh VAMC shall be coordinated through the COR/ POC, Monday through Friday; 8:00am 2:30pm. ALL INTERESTED PARTIES MUST ALSO HAVE AN ACTIVE REGISTRATION IN THE SYSTEM FOR AWARD MANAGEMENT (SAM) DATABASE. TO REGISTER, PLEASE VISIT WWW.SAM.GOV. Responses to this notice shall include:
Company Name Address Point of Contact Phone Number Email Address DUNS Number CAGE Code Tax ID Number ** Note: In accordance with the U.S. Supreme Court decision regarding Kingdomware, service disabled veteran owned (SDVOSB) and veteran owned (VOSB), who are interested in this procurement and consider themselves to have the resources and capabilities necessary to provide these services shall be verified in VetBiz Registry as follows to be considered: http://www.vip.vetbiz.gov/ . Process in 38 U.S.C.
8127(d) whereby a contracting officer of the Department shall award contracts on the basis of competition restricted to small business concerns owned and controlled by veterans, if the contracting officer has a reasonable expectation that two or more small business concerns owned and controlled by veterans will submit offers, and that the award can be made at a fair and reasonable price that offers the best value to the United States.
For purposes of this VA specific rule, a service-disabled veteran-owned small business (SDVOSB) or a veteran-owned small business (VOSB), must meet the eligibility requirements in 38 U.S.C. 8127(e), (f) and VAAR subpart 819.7003 and be listed as verified in the Vendor Information Pages (VIP) database. Please provide answers to all questions below regarding your firm s Socio-Economic status pursuant to North American Industrial Classification Code (NAICS)
339112:
1. Is your business a small business under NAICS 339112? YES
NO
2. Is your firm a Veteran-Owned Small Business? YES
NO
3. Is your firm a Service-Disabled Veteran-Owned Small Business? YES
NO
4. Is you firm a certified HUB Zone firm? YES
NO
5. Is your firm a Woman Owned business? YES
NO
6. Is your firm a Large Business? YES
NO
7. Do you have a GSA/FSS schedule for these items? YES
NO
Schedule Number:
Expiration Date:
Please provide a capability statement as well as any relevant literature addressing your organization s ability to supply the required items. Also, please include a point of contact name, phone number and email address.
Note: Questions regarding this notice should be addressed to Mae McGarry via email only. NO PHONE CALLS WILL BE ACCEPTED REGARDING THIS REQUIREMENT. Please submit all responses to this notice via e-mail to:
Mae McGarry Contract Specialist Mae.McGarry@va.gov Responses to this Sources Sought Notice are required by no later than Friday, November 1st, 2024 at 12:00 pm EST. If you are interested in submitting a response to this posting, please ensure to submit a Brochure/Specification Sheet for the product offered as well as a letter of authorization.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
October 29, 2024
Sources sought
Due November 1, 2024 at 12:00 PM EDT. SAM.gov, notice 6502ab74fb4946e194e316bca113f55f
Points of contact
- Mae McGarry, Contract Specialistmae.mcgarry@va.gov814-860-2606