{"canonical":"https://sealedbidder.com/opportunities/36c24227q0103","key":"36C24227Q0103","url":"https://sealedbidder.com/opportunities/36c24227q0103","title":"J065--Medical Gas Prevenative Maintenance and Service Albany VAMC","solicitation_number":"36C24227Q0103","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-11-12T15:00:00Z","first_posted":"2026-11-03","last_posted":"2026-11-03","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"811210","psc":"J065","set_aside":null,"place_state":"NY","place_scope":"site","site":"Albany VA Medical Center","place_state_source":null,"place_evidence":null,"place_county":"36001","place_county_name":"Albany County","place_city":"3601000","place_city_name":"Albany","winner":null,"award_amount":null,"publications":[{"notice_id":"aea16e4919cd4dc4a17d244456e53a2d","title":"J065--Medical Gas Prevenative Maintenance and Service Albany VAMC","solicitation_number":"36C24227Q0103","notice_type":"r","base_type":"r","posted":"2026-11-03","posted_at":"2026-11-03T20:58:53.973Z","due_at":"2026-11-12T15:00:00Z","due_date":"2026-11-12","cancelled":false,"archived":false,"archive_date":"2027-01-11","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/aea16e4919cd4dc4a17d244456e53a2d/view","enriched":true,"history":[{"index":1,"title":"J065--Medical Gas Prevenative Maintenance and Service Albany VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T20:58:53.973Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"aea16e4919cd4dc4a17d244456e53a2d","solicitation_number":"36C24227Q0103"}]}],"latest_notice_id":"aea16e4919cd4dc4a17d244456e53a2d","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-11-03","posted_at":"2026-11-03T20:58:53.973Z","created_at":"2026-11-03T20:58:51.712Z","modified_at":"2026-11-03T20:58:53.973Z","response_deadline":{"raw":"2026-11-12T10:00:00-05:00","utc":"2026-11-12T15:00:00Z","date":"2026-11-12","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/aea16e4919cd4dc4a17d244456e53a2d/view"},"naics":{"codes":["811210"],"primary":"811210"},"title":"J065--Medical Gas Prevenative Maintenance and Service Albany VAMC","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-01-11","archive_type":"auto_custom"},"history":[{"index":1,"title":"J065--Medical Gas Prevenative Maintenance and Service Albany VAMC","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T20:58:53.973Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"aea16e4919cd4dc4a17d244456e53a2d","solicitation_number":"36C24227Q0103"}],"contacts":[{"name":"Stephanie Decker","role":"primary","email":"Stephanie.Decker2@va.gov","phone":"716-862-7461","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"aea16e4919cd4dc4a17d244456e53a2d","lineage_id":"aea16e4919cd4dc4a17d244456e53a2d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T10:34:17.546379901Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"340f219dda5fa37af918ac10f53185bd62f785a0b6453ffbb3914550687b3ee4","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-11T10:34:17.546379901Z","first_seen_at":"2026-11-04T05:10:28.855326963Z"},"description":{"html":"Page 1 of \nThis is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law. \n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Buffalo, New York for the purpose of collecting information about a requirement where the Contractor shall provide, preventative maintenance (PM) services on each piece of equipment outlined in this scope of work at the Albany VA Medical Center   113 Holland Avenue, Syracuse, NY 12208 .  The VA is seeking to provide for this requirement as of January 1, 2027, The NAICS code identified for this requirement is NAICS Code 811210 - and NAICS Size standard of $34.0 Million.  The requirement is detailed in the Statement of Work section of this document. \n\n(e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service, are encouraged to email a capability statement and full information to Stephanie.Decker2@va.gov and reference 36C24227Q0103.  \n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, SAM UEID number and address, point of contact and social-economic. \n\nIf contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy. \nThe following information is required for determining procurement strategy and viability of sources:\n\nSet aside requirements have limitations on subcontracting. This service is located in Manhattan, NY and Brooklyn, NY. Provide your site location and supporting documentation. Given your location and proximity to the service site, how do you plan to accomplish self-performance of this work? \nIf your intention is to subcontract work, what tasks will be performed by you as the prime contractor? What tasks will require a subcontractor due to your inability to perform them within your company?  \n\nHow many years  experience does your company have in performing tasks of this nature, of this scope and this complexity? How many years of service do your proposed technicians have performing tasks of this nature, this scope, and this complexity? How many years does your proposed subcontractor have in performing tasks of this nature, this scope, and this complexity?\n\nHow many jobs of this nature, of this scope and this complexity have you performed in the past five years? \n\nHow many certified/licensed technicians does your company currently employ? \n\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired services. \n\n- Contractors shall identify pertinent point of contact for company, contractor SAM UEID number for size standard and socioeconomic verification in SAM and SBA certification database (VetCert), as well as for any intended subcontractors. \n\n- Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs. \n\n- Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. \n\n- Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable. \n\n- Contractors shall include any relevant comments about the Attachment(s) if applicable. \n\n\nBelow is the Limitation on Subcontracting   Certificate of Compliance Clause. Please complete this as part of your response. \n\n\n852.219-75Â  VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction.\nAs prescribed in 819.7011(b), insert the following clause:\nVA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION) \n(a) Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that \n(1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.]\n(i) [ X] Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6.\n(ii) [ ] General construction. In the case of a contract for general construction, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted.\n(iii) [ ] Special trade construction contractors. In the case of a contract for special trade contractors, the contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution.\n(2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution.\n(3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following:\n(i) Referral to the VA Suspension and Debarment Committee;\n(ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and\n(iii) Prosecution for violating 18 U.S.C. 1001.\n (b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed.\n(c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror's bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.\n(d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.\n\nCertification\nI hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror].\nPrinted Name of Signee:_________________________\nPrinted Title of Signee: ____________________________\nSignature: ____________________________________________\nDate: _______________________\nCompany Name and Address:____________________________________________\n\n\n\n\n\n\n\n\n \nStatement of Work  (Abridged)\nOverview\nThe Stratton VA Medical Center, Albany, NY has a requirement for Preventive Maintenance on their medical gas systems. We are currently seeking a full service and preventative maintenance contract. The contractor shall perform preventative maintenance (PM) services on each piece of equipment outlined in this scope of work.\n\n\nSCOPE OF WORK \nThe contractor shall provide all labor, materials, and equipment necessary for a full preventive maintenance program. PM shall include annual inspection and testing of the equipment. It shall also include evaluation of the medical gas system in accordance with NFPA 99, VA specifications and the terms within this statement of work. Maintenance of Dental and Medical air compressors and Dental vacuum pumps ARE included in this contract. Work must be performed by only trained, and certified technicians on facility s Medical gas systems\n\nPeriod of Performance:\nThe estimated period of performance shall be for one (1) Base Year of 12 months and four (4) 12-month option years.  The Period of Performance reads as follows:\n\nBase Year  01/01/2027   12/31/2027  \nOption Year I 01/01/2028   12/31/2028   \nOption Year II 01/01/2029   12/31/2029\nOption Year III 01/01/2030   12/31/2030\nOption Year IV 01/01/2031   12/31/2031\n\nHours of Work:\nFacility s normal operating hours are between 7:00 AM to 4:30 PM Monday through Friday, except Federal Holidays. If circumstances arise that some work is to be performed outside normal business hours, the contractor shall communicate the proposed schedule with COR and Facility s Plumbing Shop Forman.\n\nReports:\nThe contractor will provide a copy of service report to the COR. The report will include a list of all preventive maintenance checks completed, as well as, identified problems and/or deficiencies found. The contractor will provide two inspection reports to the COR following completion of evaluation. The inspection documents will include, as a minimum, test parameters consisting of terminal performance, valve testing, cross connections, alarm testing, leak detection, equipment evaluation, contaminant, particulate and dewpoint testing. The service reports must be signed by both the service provider and the COR at completion of work. An electronic version of same shall be sent to the COR.\n\nPlace of Performance:\nThe work to be performed under this contract will be performed at Stratton VA Medical Center, 113 Holland Avenue, Albany, New York, 12208.\n\n\nPM Procedures:\nThe contractor shall evaluate each existing oxygen, medical compressed air, vacuum and nitrous oxide systems. Sizing, flow, leaks, accessible piping, terminal performance, compressor or source configuration, valves, gauges, warning systems and alarms, back-up systems, vents, and contamination for compliance with current NFPA 99 specification and requirements.\n\nContractor shall perform medical air purity test.\n\nContractor employees shall be ASSE 6040 certified to perform maintenance and ASSE 6030\ncertified for inspection and testing. Minor repairs will be done while on station more difficult\nrepairs or those needing additional parts will require a quote.\n\nThere will be a system leak check using system gases and operational pressures done by the contractor where needed, tanks of appropriate gases will be used to facilitate testing. \n\nThe system check will include originating equipment, patient rooms, clinic rooms, operating rooms (see Hours of Work), emergency rooms, and any room that contains outlets which are a part of the system. The unique inventory of outlets will be provided.\n\nTerminals: Terminal screws, front and back body O-rings, locking mechanism adjustment,\nlubrication, cleaning, flow/pressure measurement and locking mechanism verification.\n\nValves: Rebuild leaking valves (ball type), cleaning and leaking inspection.\n\nAlarms: Contractor will provide lamp replacement, high- and low-pressure alarm calibration,\ncleaning and accuracy verification. Pro Flo Vacuum Enzyme Solution Injected to Aid SCFM\nPerformance: Pro Flo enzyme solution will be injected into vacuum systems terminals, ringed\nand verified to maintain maximum SCFM with minimums of 3.0 SCFM required by NFPA,\nJCAHO Standards.\n\nMedical Oxygen System: Annually\nTest area alarms for proper pressure switch location and alarm function.\nTest Oxygen system for concentration and gaseous purity at each outlet.\nTest Oxygen for particulate contamination at least once in each zone. \nTested with 0.45 micron filter device. \nTest Oxygen system for pressure at each zone.\nTest each Oxygen outlet for proper function, identification, adaptation and mechanical integrity. \nIdentify leaking/malfunctioning outlets \nIdentify outlets delivering substandard pressure/flow rates \nTest Oxygen zone shut-off valves for proper function, identification and mechanical integrity. \nCheck Oxygen pipeline for proper identification labeling.\nTest each zone for available flow. \nTest operational pressure at each station outlet/inlet  \nTest each critical care outlet operational pressure  \nTest outlet flow rate and pressure drop with high demand at adjacent outlets.\nTest Oxygen system components for leakage. \nCheck Oxygen system components for proper installation (i.e.: Brazing, Labeling,  Hanging, etc.)\nCheck for crossed lines.\n\nMedical Air System: Annually\nTest area alarms for proper pressure switch location and alarm function.\nTest Medical Air system gaseous purity. (Oxygen Concentration, Gaseous Hydrocarbons, Liquid Hydrocarbons, Carbon Monoxide, Carbon Dioxide, etc.). \nTest at source sample valve. \nTest Medical Air for particulate contamination at least once in each zone. \nTested with 0.45 micron filter device \nTest source for dew point.\nTest Medical Air System for pressure at each zone.\nTest each Medical Air outlet for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning outlets \nIdentify outlets delivering substandard pressure/flow rates                \nTest Medical Air zone shut-off valves for proper function, identification, and mechanical integrity. \nCheck Medical Air pipeline for proper identification labeling\nTest each zone for available flow.\nTest operational pressure tests at each station outlet/inlet\nTest each critical care outlet operational pressure test. \nTested outlet flow rate and pressure drop with high demand at adjacent outlets \nTest Medical Air System components for leakage.\nCheck Medical Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\n\nMedical Surgical Vacuum System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTest each Vacuum inlet for available flow rate SCFM\nTest operational pressure tests at each station outlet/inlet\nTested each Vacuum inlet for proper function, identification, adaptation, and mechanical integrity. \nIdentified leaking/malfunctioning inlets \nIdentified inlets delivering substandard vacuum/flow rate \nTest all Vacuum zone valves for proper function, identification, and mechanical integrity\nCheck Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines.\n\nNitrogen System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTested Nitrogen system for particulate contamination. \nTested with 0.45 micron filter device \nTest Nitrogen system for pressure at each zone. \nTest Nitrogen system outlets for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning outlets \nIdentify outlets delivering substandard pressure/flow rate \nTest Nitrogen zone shut-off valve for proper function, identification, and mechanical integrity. \nCheck Nitrogen pipeline for proper identification labeling.\nTest Nitrogen control panels for leakage and proper operation. \nCheck Nitrogen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\nCheck flexible connectors.\n\nNitrous Oxide System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTest Nitrous Oxide system for concentration\nTested Nitrous Oxide system for particulate contamination. \nTested with 0.45 micron filter device \nTest Nitrous Oxide system for pressure at each zone.\nTest each Nitrous Oxide outlet for proper function, identification, adaptation, and mechanical integrity. \nIdentified leaking/malfunctioning outlets \nIdentified outlets delivering substandard pressure/flow rates \nTest Nitrous Oxide zone shut-off valves for proper function, identification, and mechanical integrity. \nCheck Nitrous Oxide pipeline for proper identification labeling.\nTest each Nitrous Oxide outlet for available flow.\nTest Nitrous Oxide pipeline components for leakage.\nCheck Nitrous Oxide system components for proper installation (i.e.: Brazing, Labeling, - Hanging, etc.) \nCheck for crossed lines.\nCheck flexible connectors.\n\nDental Air System: Annually\nTest Dental Air system for pressure\nTest Dental Air zone shut-off valves for proper function, identification, and mechanical integrity. \nCheck Dental Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). \nCheck for crossed lines\n\nEvacuation/WAGD: Semi-Annually \nTest area alarms for proper pressure switch location and alarm function\nTest inches (of mercury) of E-VAC at each zone\nTest each E-VAC inlet for available flow rate SCFM.\nTested pressure at each inlet in all critical care areas. \nTested for flow rate and pressure drop with high volume demand on adjacent inlets \nTest each E- V AC inlet for proper function, identification, adaptation, and mechanical integrity. \nIdentify leaking/malfunctioning inlets \nIdentify inlets delivering substandard vacuum/flow rate \nTest all E-VAC zone valves for proper function, identification, and mechanical integrity\nCheck E-VAC system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). \nCheck for crossed lines.\n\nDental Vacuum System: Annually\nCheck Dental Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). \nCheck for crossed lines.\n\nMedical/Dental/Lab Air/Vacuum System Equipment Preventative Maintenance: Semi-Annually\nExamining items and to ensure that they maintain normal operating conditions\nExamining the seal fluid quality, quantity, temperature, and rate of rise against design specifications\nExamining the pump bearing and mechanical seals\nInspection of all relays, transformers, contacts, sequencers, indicating lamps and the wiring in the panel for faults\nGreasing of the air and vacuum pump systems in accordance with manufacturer's specifications\nInspection of demisters\nCleaning of all flow control valves, strainers, suitcase separators so that they are free of debris to insure the pump reliability and longevity. \nReplacement of failed controls. These items include but are not limited to solenoid valves, flow switches, and air unload valves. Replacement parts shall be new. \nCheck and replace belts if needed and equipped \n\n\nRepair Procedures:\nEmergency Repairs: An emergency repair shall be defined as one in which any portion of the medical gas, compressed air and vacuum systems is shutdown or is inoperable due to breakdown, malfunction, fire, or any other condition determined by the Contracting Officer s Representative (COR) or authorized Government inspector that presents an immediate danger to personnel or threatens to impair the mission of the facility. A mechanic shall be on the site ready to service the medical gas, compressed air, and vacuum systems within two (2) hours of receiving a request for emergency service call, 24 hours a day, 7 days a week.  After receiving a request for emergency service, the work shall be prosecuted continuously until the emergency is arrested.\n\nUrgent Repairs: An urgent repair shall be defined as one in which the medical gas, compressed air and vacuum system may become inoperable due to malfunction or need for servicing or threatens to impair the mission of the facility.  A mechanic shall be on the site to service the medical gas, compressed air, and vacuum systems within four (4) hours of receiving a request for urgent service, the work shall be prosecuted continuously until the urgent situation is arrested. Examples of urgent repairs includes: Medical gas system leaking seeping or weeping, power fluctuation affecting the system, or medical gas system no longer functioning. \n\nSystem shut down/standby: The government may direct the contractor to shut down the system at its convenience to allow other Government or contract work to be performed in that area.  The contractor shall be available 24 hours a day, seven days a week.  The Government will provide the contractor with a 24-hour notice of shut down service. At such time, the contractor will be provided the time and date of the shutdown, to include when the equipment will be back to operating status.  The contractor is not required to be at the job site during the period the system is shutdown.  The Contractor will be compensated for the actual time it takes to shut down the system and the actual time it takes to turn-on the system.  Standby requires the Contractor to be at the job site during specified periods, as directed by the COR.  Standby may be required when system is shutdown or when other work (i.e. construction, electrical outages, etc.) may adversely affect the system.  The Contractor will be compensated for the entire standby period.","text":"Page 1 of\nThis is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law.\n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Buffalo, New York for the purpose of collecting information about a requirement where the Contractor shall provide, preventative maintenance (PM) services on each piece of equipment outlined in this scope of work at the Albany VA Medical Center 113 Holland Avenue, Syracuse, NY 12208 . The VA is seeking to provide for this requirement as of January 1, 2027, The NAICS code identified for this requirement is NAICS Code 811210 - and NAICS Size standard of $34.0 Million. The requirement is detailed in the Statement of Work section of this document.\n\n(e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service, are encouraged to email a capability statement and full information to Stephanie.Decker2@va.gov and reference 36C24227Q0103.\n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, SAM UEID number and address, point of contact and social-economic.\n\nIf contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy.\nThe following information is required for determining procurement strategy and viability of sources:\n\nSet aside requirements have limitations on subcontracting. This service is located in Manhattan, NY and Brooklyn, NY. Provide your site location and supporting documentation. Given your location and proximity to the service site, how do you plan to accomplish self-performance of this work?\nIf your intention is to subcontract work, what tasks will be performed by you as the prime contractor? What tasks will require a subcontractor due to your inability to perform them within your company?\n\nHow many years experience does your company have in performing tasks of this nature, of this scope and this complexity? How many years of service do your proposed technicians have performing tasks of this nature, this scope, and this complexity? How many years does your proposed subcontractor have in performing tasks of this nature, this scope, and this complexity?\n\nHow many jobs of this nature, of this scope and this complexity have you performed in the past five years?\n\nHow many certified/licensed technicians does your company currently employ?\n\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired services.\n\n- Contractors shall identify pertinent point of contact for company, contractor SAM UEID number for size standard and socioeconomic verification in SAM and SBA certification database (VetCert), as well as for any intended subcontractors.\n\n- Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs.\n\n- Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded.\n\n- Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable.\n\n- Contractors shall include any relevant comments about the Attachment(s) if applicable.\n\nBelow is the Limitation on Subcontracting Certificate of Compliance Clause. Please complete this as part of your response.\n\n852.219-75Â VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction.\nAs prescribed in 819.7011(b), insert the following clause:\nVA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION)\n(a) Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that\n(1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.]\n(i) [ X] Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6.\n(ii) [ ] General construction. In the case of a contract for general construction, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted.\n(iii) [ ] Special trade construction contractors. In the case of a contract for special trade contractors, the contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution.\n(2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution.\n(3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following:\n(i) Referral to the VA Suspension and Debarment Committee;\n(ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and\n(iii) Prosecution for violating 18 U.S.C. 1001.\n(b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed.\n(c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror's bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.\n(d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.\n\nCertification\nI hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror].\nPrinted Name of Signee:_________________________\nPrinted Title of Signee: ____________________________\nSignature: ____________________________________________\nDate: _______________________\nCompany Name and Address:____________________________________________\n\nStatement of Work (Abridged)\nOverview\nThe Stratton VA Medical Center, Albany, NY has a requirement for Preventive Maintenance on their medical gas systems. We are currently seeking a full service and preventative maintenance contract. The contractor shall perform preventative maintenance (PM) services on each piece of equipment outlined in this scope of work.\n\nSCOPE OF WORK\nThe contractor shall provide all labor, materials, and equipment necessary for a full preventive maintenance program. PM shall include annual inspection and testing of the equipment. It shall also include evaluation of the medical gas system in accordance with NFPA 99, VA specifications and the terms within this statement of work. Maintenance of Dental and Medical air compressors and Dental vacuum pumps ARE included in this contract. Work must be performed by only trained, and certified technicians on facility s Medical gas systems\n\nPeriod of Performance:\nThe estimated period of performance shall be for one (1) Base Year of 12 months and four (4) 12-month option years. The Period of Performance reads as follows:\n\nBase Year 01/01/2027 12/31/2027\nOption Year I 01/01/2028 12/31/2028\nOption Year II 01/01/2029 12/31/2029\nOption Year III 01/01/2030 12/31/2030\nOption Year IV 01/01/2031 12/31/2031\n\nHours of Work:\nFacility s normal operating hours are between 7:00 AM to 4:30 PM Monday through Friday, except Federal Holidays. If circumstances arise that some work is to be performed outside normal business hours, the contractor shall communicate the proposed schedule with COR and Facility s Plumbing Shop Forman.\n\nReports:\nThe contractor will provide a copy of service report to the COR. The report will include a list of all preventive maintenance checks completed, as well as, identified problems and/or deficiencies found. The contractor will provide two inspection reports to the COR following completion of evaluation. The inspection documents will include, as a minimum, test parameters consisting of terminal performance, valve testing, cross connections, alarm testing, leak detection, equipment evaluation, contaminant, particulate and dewpoint testing. The service reports must be signed by both the service provider and the COR at completion of work. An electronic version of same shall be sent to the COR.\n\nPlace of Performance:\nThe work to be performed under this contract will be performed at Stratton VA Medical Center, 113 Holland Avenue, Albany, New York, 12208.\n\nPM Procedures:\nThe contractor shall evaluate each existing oxygen, medical compressed air, vacuum and nitrous oxide systems. Sizing, flow, leaks, accessible piping, terminal performance, compressor or source configuration, valves, gauges, warning systems and alarms, back-up systems, vents, and contamination for compliance with current NFPA 99 specification and requirements.\n\nContractor shall perform medical air purity test.\n\nContractor employees shall be ASSE 6040 certified to perform maintenance and ASSE 6030\ncertified for inspection and testing. Minor repairs will be done while on station more difficult\nrepairs or those needing additional parts will require a quote.\n\nThere will be a system leak check using system gases and operational pressures done by the contractor where needed, tanks of appropriate gases will be used to facilitate testing.\n\nThe system check will include originating equipment, patient rooms, clinic rooms, operating rooms (see Hours of Work), emergency rooms, and any room that contains outlets which are a part of the system. The unique inventory of outlets will be provided.\n\nTerminals: Terminal screws, front and back body O-rings, locking mechanism adjustment,\nlubrication, cleaning, flow/pressure measurement and locking mechanism verification.\n\nValves: Rebuild leaking valves (ball type), cleaning and leaking inspection.\n\nAlarms: Contractor will provide lamp replacement, high- and low-pressure alarm calibration,\ncleaning and accuracy verification. Pro Flo Vacuum Enzyme Solution Injected to Aid SCFM\nPerformance: Pro Flo enzyme solution will be injected into vacuum systems terminals, ringed\nand verified to maintain maximum SCFM with minimums of 3.0 SCFM required by NFPA,\nJCAHO Standards.\n\nMedical Oxygen System: Annually\nTest area alarms for proper pressure switch location and alarm function.\nTest Oxygen system for concentration and gaseous purity at each outlet.\nTest Oxygen for particulate contamination at least once in each zone.\nTested with 0.45 micron filter device.\nTest Oxygen system for pressure at each zone.\nTest each Oxygen outlet for proper function, identification, adaptation and mechanical integrity.\nIdentify leaking/malfunctioning outlets\nIdentify outlets delivering substandard pressure/flow rates\nTest Oxygen zone shut-off valves for proper function, identification and mechanical integrity.\nCheck Oxygen pipeline for proper identification labeling.\nTest each zone for available flow.\nTest operational pressure at each station outlet/inlet\nTest each critical care outlet operational pressure\nTest outlet flow rate and pressure drop with high demand at adjacent outlets.\nTest Oxygen system components for leakage.\nCheck Oxygen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\n\nMedical Air System: Annually\nTest area alarms for proper pressure switch location and alarm function.\nTest Medical Air system gaseous purity. (Oxygen Concentration, Gaseous Hydrocarbons, Liquid Hydrocarbons, Carbon Monoxide, Carbon Dioxide, etc.).\nTest at source sample valve.\nTest Medical Air for particulate contamination at least once in each zone.\nTested with 0.45 micron filter device\nTest source for dew point.\nTest Medical Air System for pressure at each zone.\nTest each Medical Air outlet for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning outlets\nIdentify outlets delivering substandard pressure/flow rates\nTest Medical Air zone shut-off valves for proper function, identification, and mechanical integrity.\nCheck Medical Air pipeline for proper identification labeling\nTest each zone for available flow.\nTest operational pressure tests at each station outlet/inlet\nTest each critical care outlet operational pressure test.\nTested outlet flow rate and pressure drop with high demand at adjacent outlets\nTest Medical Air System components for leakage.\nCheck Medical Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\n\nMedical Surgical Vacuum System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTest each Vacuum inlet for available flow rate SCFM\nTest operational pressure tests at each station outlet/inlet\nTested each Vacuum inlet for proper function, identification, adaptation, and mechanical integrity.\nIdentified leaking/malfunctioning inlets\nIdentified inlets delivering substandard vacuum/flow rate\nTest all Vacuum zone valves for proper function, identification, and mechanical integrity\nCheck Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines.\n\nNitrogen System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTested Nitrogen system for particulate contamination.\nTested with 0.45 micron filter device\nTest Nitrogen system for pressure at each zone.\nTest Nitrogen system outlets for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning outlets\nIdentify outlets delivering substandard pressure/flow rate\nTest Nitrogen zone shut-off valve for proper function, identification, and mechanical integrity.\nCheck Nitrogen pipeline for proper identification labeling.\nTest Nitrogen control panels for leakage and proper operation.\nCheck Nitrogen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\nCheck flexible connectors.\n\nNitrous Oxide System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTest Nitrous Oxide system for concentration\nTested Nitrous Oxide system for particulate contamination.\nTested with 0.45 micron filter device\nTest Nitrous Oxide system for pressure at each zone.\nTest each Nitrous Oxide outlet for proper function, identification, adaptation, and mechanical integrity.\nIdentified leaking/malfunctioning outlets\nIdentified outlets delivering substandard pressure/flow rates\nTest Nitrous Oxide zone shut-off valves for proper function, identification, and mechanical integrity.\nCheck Nitrous Oxide pipeline for proper identification labeling.\nTest each Nitrous Oxide outlet for available flow.\nTest Nitrous Oxide pipeline components for leakage.\nCheck Nitrous Oxide system components for proper installation (i.e.: Brazing, Labeling, - Hanging, etc.)\nCheck for crossed lines.\nCheck flexible connectors.\n\nDental Air System: Annually\nTest Dental Air system for pressure\nTest Dental Air zone shut-off valves for proper function, identification, and mechanical integrity.\nCheck Dental Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines\n\nEvacuation/WAGD: Semi-Annually\nTest area alarms for proper pressure switch location and alarm function\nTest inches (of mercury) of E-VAC at each zone\nTest each E-VAC inlet for available flow rate SCFM.\nTested pressure at each inlet in all critical care areas.\nTested for flow rate and pressure drop with high volume demand on adjacent inlets\nTest each E- V AC inlet for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning inlets\nIdentify inlets delivering substandard vacuum/flow rate\nTest all E-VAC zone valves for proper function, identification, and mechanical integrity\nCheck E-VAC system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines.\n\nDental Vacuum System: Annually\nCheck Dental Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines.\n\nMedical/Dental/Lab Air/Vacuum System Equipment Preventative Maintenance: Semi-Annually\nExamining items and to ensure that they maintain normal operating conditions\nExamining the seal fluid quality, quantity, temperature, and rate of rise against design specifications\nExamining the pump bearing and mechanical seals\nInspection of all relays, transformers, contacts, sequencers, indicating lamps and the wiring in the panel for faults\nGreasing of the air and vacuum pump systems in accordance with manufacturer's specifications\nInspection of demisters\nCleaning of all flow control valves, strainers, suitcase separators so that they are free of debris to insure the pump reliability and longevity.\nReplacement of failed controls. These items include but are not limited to solenoid valves, flow switches, and air unload valves. Replacement parts shall be new.\nCheck and replace belts if needed and equipped\n\nRepair Procedures:\nEmergency Repairs: An emergency repair shall be defined as one in which any portion of the medical gas, compressed air and vacuum systems is shutdown or is inoperable due to breakdown, malfunction, fire, or any other condition determined by the Contracting Officer s Representative (COR) or authorized Government inspector that presents an immediate danger to personnel or threatens to impair the mission of the facility. A mechanic shall be on the site ready to service the medical gas, compressed air, and vacuum systems within two (2) hours of receiving a request for emergency service call, 24 hours a day, 7 days a week. After receiving a request for emergency service, the work shall be prosecuted continuously until the emergency is arrested.\n\nUrgent Repairs: An urgent repair shall be defined as one in which the medical gas, compressed air and vacuum system may become inoperable due to malfunction or need for servicing or threatens to impair the mission of the facility. A mechanic shall be on the site to service the medical gas, compressed air, and vacuum systems within four (4) hours of receiving a request for urgent service, the work shall be prosecuted continuously until the urgent situation is arrested. Examples of urgent repairs includes: Medical gas system leaking seeping or weeping, power fluctuation affecting the system, or medical gas system no longer functioning.\n\nSystem shut down/standby: The government may direct the contractor to shut down the system at its convenience to allow other Government or contract work to be performed in that area. The contractor shall be available 24 hours a day, seven days a week. The Government will provide the contractor with a 24-hour notice of shut down service. At such time, the contractor will be provided the time and date of the shutdown, to include when the equipment will be back to operating status. The contractor is not required to be at the job site during the period the system is shutdown. The Contractor will be compensated for the actual time it takes to shut down the system and the actual time it takes to turn-on the system. Standby requires the Contractor to be at the job site during specified periods, as directed by the COR. Standby may be required when system is shutdown or when other work (i.e. construction, electrical outages, etc.) may adversely affect the system. The Contractor will be compensated for the entire standby period.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24227Q0103","place_of_performance":{"zip":"12208","city":{"code":"1000","name":"Albany"},"state":{"code":"NY","name":"New York"},"street":"Department of Veteran Affairs Albany VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"113 Holland Ave"},"product_service_code":"J065"}],"due_at":"2026-11-12T15:00:00Z","due_date":"2026-11-12","closes_at":"2026-11-12T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36001","county_name":"Albany County","city":"3601000","city_name":"Albany","country":"USA","state_source":null,"state_evidence":null,"site_key":"albany-va-medical-center-ny","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-04T05:14:00.353426Z","principal_notice_id":"aea16e4919cd4dc4a17d244456e53a2d","description":{"text":"Page 1 of\nThis is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law.\n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Buffalo, New York for the purpose of collecting information about a requirement where the Contractor shall provide, preventative maintenance (PM) services on each piece of equipment outlined in this scope of work at the Albany VA Medical Center 113 Holland Avenue, Syracuse, NY 12208 . The VA is seeking to provide for this requirement as of January 1, 2027, The NAICS code identified for this requirement is NAICS Code 811210 - and NAICS Size standard of $34.0 Million. The requirement is detailed in the Statement of Work section of this document.\n\n(e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service, are encouraged to email a capability statement and full information to Stephanie.Decker2@va.gov and reference 36C24227Q0103.\n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, SAM UEID number and address, point of contact and social-economic.\n\nIf contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy.\nThe following information is required for determining procurement strategy and viability of sources:\n\nSet aside requirements have limitations on subcontracting. This service is located in Manhattan, NY and Brooklyn, NY. Provide your site location and supporting documentation. Given your location and proximity to the service site, how do you plan to accomplish self-performance of this work?\nIf your intention is to subcontract work, what tasks will be performed by you as the prime contractor? What tasks will require a subcontractor due to your inability to perform them within your company?\n\nHow many years experience does your company have in performing tasks of this nature, of this scope and this complexity? How many years of service do your proposed technicians have performing tasks of this nature, this scope, and this complexity? How many years does your proposed subcontractor have in performing tasks of this nature, this scope, and this complexity?\n\nHow many jobs of this nature, of this scope and this complexity have you performed in the past five years?\n\nHow many certified/licensed technicians does your company currently employ?\n\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired services.\n\n- Contractors shall identify pertinent point of contact for company, contractor SAM UEID number for size standard and socioeconomic verification in SAM and SBA certification database (VetCert), as well as for any intended subcontractors.\n\n- Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs.\n\n- Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded.\n\n- Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable.\n\n- Contractors shall include any relevant comments about the Attachment(s) if applicable.\n\nBelow is the Limitation on Subcontracting Certificate of Compliance Clause. Please complete this as part of your response.\n\n852.219-75Â VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction.\nAs prescribed in 819.7011(b), insert the following clause:\nVA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION)\n(a) Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that\n(1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.]\n(i) [ X] Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6.\n(ii) [ ] General construction. In the case of a contract for general construction, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted.\n(iii) [ ] Special trade construction contractors. In the case of a contract for special trade contractors, the contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution.\n(2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution.\n(3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following:\n(i) Referral to the VA Suspension and Debarment Committee;\n(ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and\n(iii) Prosecution for violating 18 U.S.C. 1001.\n(b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed.\n(c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror's bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.\n(d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.\n\nCertification\nI hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror].\nPrinted Name of Signee:_________________________\nPrinted Title of Signee: ____________________________\nSignature: ____________________________________________\nDate: _______________________\nCompany Name and Address:____________________________________________\n\nStatement of Work (Abridged)\nOverview\nThe Stratton VA Medical Center, Albany, NY has a requirement for Preventive Maintenance on their medical gas systems. We are currently seeking a full service and preventative maintenance contract. The contractor shall perform preventative maintenance (PM) services on each piece of equipment outlined in this scope of work.\n\nSCOPE OF WORK\nThe contractor shall provide all labor, materials, and equipment necessary for a full preventive maintenance program. PM shall include annual inspection and testing of the equipment. It shall also include evaluation of the medical gas system in accordance with NFPA 99, VA specifications and the terms within this statement of work. Maintenance of Dental and Medical air compressors and Dental vacuum pumps ARE included in this contract. Work must be performed by only trained, and certified technicians on facility s Medical gas systems\n\nPeriod of Performance:\nThe estimated period of performance shall be for one (1) Base Year of 12 months and four (4) 12-month option years. The Period of Performance reads as follows:\n\nBase Year 01/01/2027 12/31/2027\nOption Year I 01/01/2028 12/31/2028\nOption Year II 01/01/2029 12/31/2029\nOption Year III 01/01/2030 12/31/2030\nOption Year IV 01/01/2031 12/31/2031\n\nHours of Work:\nFacility s normal operating hours are between 7:00 AM to 4:30 PM Monday through Friday, except Federal Holidays. If circumstances arise that some work is to be performed outside normal business hours, the contractor shall communicate the proposed schedule with COR and Facility s Plumbing Shop Forman.\n\nReports:\nThe contractor will provide a copy of service report to the COR. The report will include a list of all preventive maintenance checks completed, as well as, identified problems and/or deficiencies found. The contractor will provide two inspection reports to the COR following completion of evaluation. The inspection documents will include, as a minimum, test parameters consisting of terminal performance, valve testing, cross connections, alarm testing, leak detection, equipment evaluation, contaminant, particulate and dewpoint testing. The service reports must be signed by both the service provider and the COR at completion of work. An electronic version of same shall be sent to the COR.\n\nPlace of Performance:\nThe work to be performed under this contract will be performed at Stratton VA Medical Center, 113 Holland Avenue, Albany, New York, 12208.\n\nPM Procedures:\nThe contractor shall evaluate each existing oxygen, medical compressed air, vacuum and nitrous oxide systems. Sizing, flow, leaks, accessible piping, terminal performance, compressor or source configuration, valves, gauges, warning systems and alarms, back-up systems, vents, and contamination for compliance with current NFPA 99 specification and requirements.\n\nContractor shall perform medical air purity test.\n\nContractor employees shall be ASSE 6040 certified to perform maintenance and ASSE 6030\ncertified for inspection and testing. Minor repairs will be done while on station more difficult\nrepairs or those needing additional parts will require a quote.\n\nThere will be a system leak check using system gases and operational pressures done by the contractor where needed, tanks of appropriate gases will be used to facilitate testing.\n\nThe system check will include originating equipment, patient rooms, clinic rooms, operating rooms (see Hours of Work), emergency rooms, and any room that contains outlets which are a part of the system. The unique inventory of outlets will be provided.\n\nTerminals: Terminal screws, front and back body O-rings, locking mechanism adjustment,\nlubrication, cleaning, flow/pressure measurement and locking mechanism verification.\n\nValves: Rebuild leaking valves (ball type), cleaning and leaking inspection.\n\nAlarms: Contractor will provide lamp replacement, high- and low-pressure alarm calibration,\ncleaning and accuracy verification. Pro Flo Vacuum Enzyme Solution Injected to Aid SCFM\nPerformance: Pro Flo enzyme solution will be injected into vacuum systems terminals, ringed\nand verified to maintain maximum SCFM with minimums of 3.0 SCFM required by NFPA,\nJCAHO Standards.\n\nMedical Oxygen System: Annually\nTest area alarms for proper pressure switch location and alarm function.\nTest Oxygen system for concentration and gaseous purity at each outlet.\nTest Oxygen for particulate contamination at least once in each zone.\nTested with 0.45 micron filter device.\nTest Oxygen system for pressure at each zone.\nTest each Oxygen outlet for proper function, identification, adaptation and mechanical integrity.\nIdentify leaking/malfunctioning outlets\nIdentify outlets delivering substandard pressure/flow rates\nTest Oxygen zone shut-off valves for proper function, identification and mechanical integrity.\nCheck Oxygen pipeline for proper identification labeling.\nTest each zone for available flow.\nTest operational pressure at each station outlet/inlet\nTest each critical care outlet operational pressure\nTest outlet flow rate and pressure drop with high demand at adjacent outlets.\nTest Oxygen system components for leakage.\nCheck Oxygen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\n\nMedical Air System: Annually\nTest area alarms for proper pressure switch location and alarm function.\nTest Medical Air system gaseous purity. (Oxygen Concentration, Gaseous Hydrocarbons, Liquid Hydrocarbons, Carbon Monoxide, Carbon Dioxide, etc.).\nTest at source sample valve.\nTest Medical Air for particulate contamination at least once in each zone.\nTested with 0.45 micron filter device\nTest source for dew point.\nTest Medical Air System for pressure at each zone.\nTest each Medical Air outlet for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning outlets\nIdentify outlets delivering substandard pressure/flow rates\nTest Medical Air zone shut-off valves for proper function, identification, and mechanical integrity.\nCheck Medical Air pipeline for proper identification labeling\nTest each zone for available flow.\nTest operational pressure tests at each station outlet/inlet\nTest each critical care outlet operational pressure test.\nTested outlet flow rate and pressure drop with high demand at adjacent outlets\nTest Medical Air System components for leakage.\nCheck Medical Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\n\nMedical Surgical Vacuum System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTest each Vacuum inlet for available flow rate SCFM\nTest operational pressure tests at each station outlet/inlet\nTested each Vacuum inlet for proper function, identification, adaptation, and mechanical integrity.\nIdentified leaking/malfunctioning inlets\nIdentified inlets delivering substandard vacuum/flow rate\nTest all Vacuum zone valves for proper function, identification, and mechanical integrity\nCheck Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines.\n\nNitrogen System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTested Nitrogen system for particulate contamination.\nTested with 0.45 micron filter device\nTest Nitrogen system for pressure at each zone.\nTest Nitrogen system outlets for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning outlets\nIdentify outlets delivering substandard pressure/flow rate\nTest Nitrogen zone shut-off valve for proper function, identification, and mechanical integrity.\nCheck Nitrogen pipeline for proper identification labeling.\nTest Nitrogen control panels for leakage and proper operation.\nCheck Nitrogen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\nCheck flexible connectors.\n\nNitrous Oxide System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTest Nitrous Oxide system for concentration\nTested Nitrous Oxide system for particulate contamination.\nTested with 0.45 micron filter device\nTest Nitrous Oxide system for pressure at each zone.\nTest each Nitrous Oxide outlet for proper function, identification, adaptation, and mechanical integrity.\nIdentified leaking/malfunctioning outlets\nIdentified outlets delivering substandard pressure/flow rates\nTest Nitrous Oxide zone shut-off valves for proper function, identification, and mechanical integrity.\nCheck Nitrous Oxide pipeline for proper identification labeling.\nTest each Nitrous Oxide outlet for available flow.\nTest Nitrous Oxide pipeline components for leakage.\nCheck Nitrous Oxide system components for proper installation (i.e.: Brazing, Labeling, - Hanging, etc.)\nCheck for crossed lines.\nCheck flexible connectors.\n\nDental Air System: Annually\nTest Dental Air system for pressure\nTest Dental Air zone shut-off valves for proper function, identification, and mechanical integrity.\nCheck Dental Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines\n\nEvacuation/WAGD: Semi-Annually\nTest area alarms for proper pressure switch location and alarm function\nTest inches (of mercury) of E-VAC at each zone\nTest each E-VAC inlet for available flow rate SCFM.\nTested pressure at each inlet in all critical care areas.\nTested for flow rate and pressure drop with high volume demand on adjacent inlets\nTest each E- V AC inlet for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning inlets\nIdentify inlets delivering substandard vacuum/flow rate\nTest all E-VAC zone valves for proper function, identification, and mechanical integrity\nCheck E-VAC system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines.\n\nDental Vacuum System: Annually\nCheck Dental Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines.\n\nMedical/Dental/Lab Air/Vacuum System Equipment Preventative Maintenance: Semi-Annually\nExamining items and to ensure that they maintain normal operating conditions\nExamining the seal fluid quality, quantity, temperature, and rate of rise against design specifications\nExamining the pump bearing and mechanical seals\nInspection of all relays, transformers, contacts, sequencers, indicating lamps and the wiring in the panel for faults\nGreasing of the air and vacuum pump systems in accordance with manufacturer's specifications\nInspection of demisters\nCleaning of all flow control valves, strainers, suitcase separators so that they are free of debris to insure the pump reliability and longevity.\nReplacement of failed controls. These items include but are not limited to solenoid valves, flow switches, and air unload valves. Replacement parts shall be new.\nCheck and replace belts if needed and equipped\n\nRepair Procedures:\nEmergency Repairs: An emergency repair shall be defined as one in which any portion of the medical gas, compressed air and vacuum systems is shutdown or is inoperable due to breakdown, malfunction, fire, or any other condition determined by the Contracting Officer s Representative (COR) or authorized Government inspector that presents an immediate danger to personnel or threatens to impair the mission of the facility. A mechanic shall be on the site ready to service the medical gas, compressed air, and vacuum systems within two (2) hours of receiving a request for emergency service call, 24 hours a day, 7 days a week. After receiving a request for emergency service, the work shall be prosecuted continuously until the emergency is arrested.\n\nUrgent Repairs: An urgent repair shall be defined as one in which the medical gas, compressed air and vacuum system may become inoperable due to malfunction or need for servicing or threatens to impair the mission of the facility. A mechanic shall be on the site to service the medical gas, compressed air, and vacuum systems within four (4) hours of receiving a request for urgent service, the work shall be prosecuted continuously until the urgent situation is arrested. Examples of urgent repairs includes: Medical gas system leaking seeping or weeping, power fluctuation affecting the system, or medical gas system no longer functioning.\n\nSystem shut down/standby: The government may direct the contractor to shut down the system at its convenience to allow other Government or contract work to be performed in that area. The contractor shall be available 24 hours a day, seven days a week. The Government will provide the contractor with a 24-hour notice of shut down service. At such time, the contractor will be provided the time and date of the shutdown, to include when the equipment will be back to operating status. The contractor is not required to be at the job site during the period the system is shutdown. The Contractor will be compensated for the actual time it takes to shut down the system and the actual time it takes to turn-on the system. Standby requires the Contractor to be at the job site during specified periods, as directed by the COR. Standby may be required when system is shutdown or when other work (i.e. construction, electrical outages, etc.) may adversely affect the system. The Contractor will be compensated for the entire standby period.","html":"Page 1 of \nThis is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law. \n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Buffalo, New York for the purpose of collecting information about a requirement where the Contractor shall provide, preventative maintenance (PM) services on each piece of equipment outlined in this scope of work at the Albany VA Medical Center   113 Holland Avenue, Syracuse, NY 12208 .  The VA is seeking to provide for this requirement as of January 1, 2027, The NAICS code identified for this requirement is NAICS Code 811210 - and NAICS Size standard of $34.0 Million.  The requirement is detailed in the Statement of Work section of this document. \n\n(e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service, are encouraged to email a capability statement and full information to Stephanie.Decker2@va.gov and reference 36C24227Q0103.  \n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, SAM UEID number and address, point of contact and social-economic. \n\nIf contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy. \nThe following information is required for determining procurement strategy and viability of sources:\n\nSet aside requirements have limitations on subcontracting. This service is located in Manhattan, NY and Brooklyn, NY. Provide your site location and supporting documentation. Given your location and proximity to the service site, how do you plan to accomplish self-performance of this work? \nIf your intention is to subcontract work, what tasks will be performed by you as the prime contractor? What tasks will require a subcontractor due to your inability to perform them within your company?  \n\nHow many years  experience does your company have in performing tasks of this nature, of this scope and this complexity? How many years of service do your proposed technicians have performing tasks of this nature, this scope, and this complexity? How many years does your proposed subcontractor have in performing tasks of this nature, this scope, and this complexity?\n\nHow many jobs of this nature, of this scope and this complexity have you performed in the past five years? \n\nHow many certified/licensed technicians does your company currently employ? \n\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired services. \n\n- Contractors shall identify pertinent point of contact for company, contractor SAM UEID number for size standard and socioeconomic verification in SAM and SBA certification database (VetCert), as well as for any intended subcontractors. \n\n- Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs. \n\n- Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. \n\n- Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable. \n\n- Contractors shall include any relevant comments about the Attachment(s) if applicable. \n\n\nBelow is the Limitation on Subcontracting   Certificate of Compliance Clause. Please complete this as part of your response. \n\n\n852.219-75Â  VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction.\nAs prescribed in 819.7011(b), insert the following clause:\nVA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATE OF COMPLIANCE FOR SERVICES AND CONSTRUCTION (JAN 2023) (DEVIATION) \n(a) Pursuant to 38 U.S.C. 8127(l)(2), the offeror certifies that \n(1) If awarded a contract (see FAR 2.101 definition), it will comply with the limitations on subcontracting requirement as provided in the solicitation and the resultant contract, as follows: [Contracting Officer check the appropriate box below based on the predominant NAICS code assigned to the instant acquisition as set forth in FAR 19.102.]\n(i) [ X] Services. In the case of a contract for services (except construction), the contractor will not pay more than 50% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDVOSB/VOSB subcontractor further subcontracts will count towards the 50% subcontract amount that cannot be exceeded. Other direct costs may be excluded to the extent they are not the principal purpose of the acquisition and small business concerns do not provide the service as set forth in 13 CFR 125.6.\n(ii) [ ] General construction. In the case of a contract for general construction, the contractor will not pay more than 85% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 85% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted.\n(iii) [ ] Special trade construction contractors. In the case of a contract for special trade contractors, the contractor will not pay more than 75% of the amount paid by the government to it to firms that are not certified SDVOSBs listed in the SBA certification database as set forth in 852.219-73 or certified VOSBs listed in the SBA certification database as set forth in 852.219-74. Any work that a similarly situated certified SDBOSB/VOSB subcontractor further subcontracts will count towards the 75% subcontract amount that cannot be exceeded. Cost of materials are excluded and not considered to be subcontracted. (2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution.\n(2) The offeror acknowledges that this certification concerns a matter within the jurisdiction of an Agency of the United States. The offeror further acknowledges that this certification is subject to Title 18, United States Code, Section 1001, and, as such, a false, fictitious, or fraudulent certification may render the offeror subject to criminal, civil, or administrative penalties, including prosecution.\n(3) If VA determines that an SDVOSB/VOSB awarded a contract pursuant to 38 U.S.C. 8127 did not act in good faith, such SDVOSB/VOSB shall be subject to any or all of the following:\n(i) Referral to the VA Suspension and Debarment Committee;\n(ii) A fine under section 16(g)(1) of the Small Business Act (15 U.S.C. 645(g)(1)); and\n(iii) Prosecution for violating 18 U.S.C. 1001.\n (b) The offeror represents and understands that by submission of its offer and award of a contract it may be required to provide copies of documents or records to VA that VA may review to determine whether the offeror complied with the limitations on subcontracting requirement specified in the contract. Contracting officers may, at their discretion, require the contractor to demonstrate its compliance with the limitations on subcontracting at any time during performance and upon completion of a contract if the information regarding such compliance is not already available to the contracting officer. Evidence of compliance includes, but is not limited to, invoices, copies of subcontracts, or a list of the value of tasks performed.\n(c) The offeror further agrees to cooperate fully and make available any documents or records as may be required to enable VA to determine compliance with the limitations on subcontracting requirement. The offeror understands that failure to provide documents as requested by VA may result in remedial action as the Government deems appropriate. (d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror's bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.\n(d) Offeror completed certification/fill-in required. The formal certification must be completed, signed and returned with the offeror s bid, quotation, or proposal. The Government will not consider offers for award from offerors that do not provide the certification, and all such responses will be deemed ineligible for evaluation and award.\n\nCertification\nI hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror].\nPrinted Name of Signee:_________________________\nPrinted Title of Signee: ____________________________\nSignature: ____________________________________________\nDate: _______________________\nCompany Name and Address:____________________________________________\n\n\n\n\n\n\n\n\n \nStatement of Work  (Abridged)\nOverview\nThe Stratton VA Medical Center, Albany, NY has a requirement for Preventive Maintenance on their medical gas systems. We are currently seeking a full service and preventative maintenance contract. The contractor shall perform preventative maintenance (PM) services on each piece of equipment outlined in this scope of work.\n\n\nSCOPE OF WORK \nThe contractor shall provide all labor, materials, and equipment necessary for a full preventive maintenance program. PM shall include annual inspection and testing of the equipment. It shall also include evaluation of the medical gas system in accordance with NFPA 99, VA specifications and the terms within this statement of work. Maintenance of Dental and Medical air compressors and Dental vacuum pumps ARE included in this contract. Work must be performed by only trained, and certified technicians on facility s Medical gas systems\n\nPeriod of Performance:\nThe estimated period of performance shall be for one (1) Base Year of 12 months and four (4) 12-month option years.  The Period of Performance reads as follows:\n\nBase Year  01/01/2027   12/31/2027  \nOption Year I 01/01/2028   12/31/2028   \nOption Year II 01/01/2029   12/31/2029\nOption Year III 01/01/2030   12/31/2030\nOption Year IV 01/01/2031   12/31/2031\n\nHours of Work:\nFacility s normal operating hours are between 7:00 AM to 4:30 PM Monday through Friday, except Federal Holidays. If circumstances arise that some work is to be performed outside normal business hours, the contractor shall communicate the proposed schedule with COR and Facility s Plumbing Shop Forman.\n\nReports:\nThe contractor will provide a copy of service report to the COR. The report will include a list of all preventive maintenance checks completed, as well as, identified problems and/or deficiencies found. The contractor will provide two inspection reports to the COR following completion of evaluation. The inspection documents will include, as a minimum, test parameters consisting of terminal performance, valve testing, cross connections, alarm testing, leak detection, equipment evaluation, contaminant, particulate and dewpoint testing. The service reports must be signed by both the service provider and the COR at completion of work. An electronic version of same shall be sent to the COR.\n\nPlace of Performance:\nThe work to be performed under this contract will be performed at Stratton VA Medical Center, 113 Holland Avenue, Albany, New York, 12208.\n\n\nPM Procedures:\nThe contractor shall evaluate each existing oxygen, medical compressed air, vacuum and nitrous oxide systems. Sizing, flow, leaks, accessible piping, terminal performance, compressor or source configuration, valves, gauges, warning systems and alarms, back-up systems, vents, and contamination for compliance with current NFPA 99 specification and requirements.\n\nContractor shall perform medical air purity test.\n\nContractor employees shall be ASSE 6040 certified to perform maintenance and ASSE 6030\ncertified for inspection and testing. Minor repairs will be done while on station more difficult\nrepairs or those needing additional parts will require a quote.\n\nThere will be a system leak check using system gases and operational pressures done by the contractor where needed, tanks of appropriate gases will be used to facilitate testing. \n\nThe system check will include originating equipment, patient rooms, clinic rooms, operating rooms (see Hours of Work), emergency rooms, and any room that contains outlets which are a part of the system. The unique inventory of outlets will be provided.\n\nTerminals: Terminal screws, front and back body O-rings, locking mechanism adjustment,\nlubrication, cleaning, flow/pressure measurement and locking mechanism verification.\n\nValves: Rebuild leaking valves (ball type), cleaning and leaking inspection.\n\nAlarms: Contractor will provide lamp replacement, high- and low-pressure alarm calibration,\ncleaning and accuracy verification. Pro Flo Vacuum Enzyme Solution Injected to Aid SCFM\nPerformance: Pro Flo enzyme solution will be injected into vacuum systems terminals, ringed\nand verified to maintain maximum SCFM with minimums of 3.0 SCFM required by NFPA,\nJCAHO Standards.\n\nMedical Oxygen System: Annually\nTest area alarms for proper pressure switch location and alarm function.\nTest Oxygen system for concentration and gaseous purity at each outlet.\nTest Oxygen for particulate contamination at least once in each zone. \nTested with 0.45 micron filter device. \nTest Oxygen system for pressure at each zone.\nTest each Oxygen outlet for proper function, identification, adaptation and mechanical integrity. \nIdentify leaking/malfunctioning outlets \nIdentify outlets delivering substandard pressure/flow rates \nTest Oxygen zone shut-off valves for proper function, identification and mechanical integrity. \nCheck Oxygen pipeline for proper identification labeling.\nTest each zone for available flow. \nTest operational pressure at each station outlet/inlet  \nTest each critical care outlet operational pressure  \nTest outlet flow rate and pressure drop with high demand at adjacent outlets.\nTest Oxygen system components for leakage. \nCheck Oxygen system components for proper installation (i.e.: Brazing, Labeling,  Hanging, etc.)\nCheck for crossed lines.\n\nMedical Air System: Annually\nTest area alarms for proper pressure switch location and alarm function.\nTest Medical Air system gaseous purity. (Oxygen Concentration, Gaseous Hydrocarbons, Liquid Hydrocarbons, Carbon Monoxide, Carbon Dioxide, etc.). \nTest at source sample valve. \nTest Medical Air for particulate contamination at least once in each zone. \nTested with 0.45 micron filter device \nTest source for dew point.\nTest Medical Air System for pressure at each zone.\nTest each Medical Air outlet for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning outlets \nIdentify outlets delivering substandard pressure/flow rates                \nTest Medical Air zone shut-off valves for proper function, identification, and mechanical integrity. \nCheck Medical Air pipeline for proper identification labeling\nTest each zone for available flow.\nTest operational pressure tests at each station outlet/inlet\nTest each critical care outlet operational pressure test. \nTested outlet flow rate and pressure drop with high demand at adjacent outlets \nTest Medical Air System components for leakage.\nCheck Medical Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\n\nMedical Surgical Vacuum System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTest each Vacuum inlet for available flow rate SCFM\nTest operational pressure tests at each station outlet/inlet\nTested each Vacuum inlet for proper function, identification, adaptation, and mechanical integrity. \nIdentified leaking/malfunctioning inlets \nIdentified inlets delivering substandard vacuum/flow rate \nTest all Vacuum zone valves for proper function, identification, and mechanical integrity\nCheck Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.).\nCheck for crossed lines.\n\nNitrogen System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTested Nitrogen system for particulate contamination. \nTested with 0.45 micron filter device \nTest Nitrogen system for pressure at each zone. \nTest Nitrogen system outlets for proper function, identification, adaptation, and mechanical integrity.\nIdentify leaking/malfunctioning outlets \nIdentify outlets delivering substandard pressure/flow rate \nTest Nitrogen zone shut-off valve for proper function, identification, and mechanical integrity. \nCheck Nitrogen pipeline for proper identification labeling.\nTest Nitrogen control panels for leakage and proper operation. \nCheck Nitrogen system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.)\nCheck for crossed lines.\nCheck flexible connectors.\n\nNitrous Oxide System: Annually\nTest area alarms for proper pressure switch location and alarm function\nTest Nitrous Oxide system for concentration\nTested Nitrous Oxide system for particulate contamination. \nTested with 0.45 micron filter device \nTest Nitrous Oxide system for pressure at each zone.\nTest each Nitrous Oxide outlet for proper function, identification, adaptation, and mechanical integrity. \nIdentified leaking/malfunctioning outlets \nIdentified outlets delivering substandard pressure/flow rates \nTest Nitrous Oxide zone shut-off valves for proper function, identification, and mechanical integrity. \nCheck Nitrous Oxide pipeline for proper identification labeling.\nTest each Nitrous Oxide outlet for available flow.\nTest Nitrous Oxide pipeline components for leakage.\nCheck Nitrous Oxide system components for proper installation (i.e.: Brazing, Labeling, - Hanging, etc.) \nCheck for crossed lines.\nCheck flexible connectors.\n\nDental Air System: Annually\nTest Dental Air system for pressure\nTest Dental Air zone shut-off valves for proper function, identification, and mechanical integrity. \nCheck Dental Air system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). \nCheck for crossed lines\n\nEvacuation/WAGD: Semi-Annually \nTest area alarms for proper pressure switch location and alarm function\nTest inches (of mercury) of E-VAC at each zone\nTest each E-VAC inlet for available flow rate SCFM.\nTested pressure at each inlet in all critical care areas. \nTested for flow rate and pressure drop with high volume demand on adjacent inlets \nTest each E- V AC inlet for proper function, identification, adaptation, and mechanical integrity. \nIdentify leaking/malfunctioning inlets \nIdentify inlets delivering substandard vacuum/flow rate \nTest all E-VAC zone valves for proper function, identification, and mechanical integrity\nCheck E-VAC system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). \nCheck for crossed lines.\n\nDental Vacuum System: Annually\nCheck Dental Vacuum system components for proper installation (i.e.: Brazing, Labeling, Hanging, etc.). \nCheck for crossed lines.\n\nMedical/Dental/Lab Air/Vacuum System Equipment Preventative Maintenance: Semi-Annually\nExamining items and to ensure that they maintain normal operating conditions\nExamining the seal fluid quality, quantity, temperature, and rate of rise against design specifications\nExamining the pump bearing and mechanical seals\nInspection of all relays, transformers, contacts, sequencers, indicating lamps and the wiring in the panel for faults\nGreasing of the air and vacuum pump systems in accordance with manufacturer's specifications\nInspection of demisters\nCleaning of all flow control valves, strainers, suitcase separators so that they are free of debris to insure the pump reliability and longevity. \nReplacement of failed controls. These items include but are not limited to solenoid valves, flow switches, and air unload valves. Replacement parts shall be new. \nCheck and replace belts if needed and equipped \n\n\nRepair Procedures:\nEmergency Repairs: An emergency repair shall be defined as one in which any portion of the medical gas, compressed air and vacuum systems is shutdown or is inoperable due to breakdown, malfunction, fire, or any other condition determined by the Contracting Officer s Representative (COR) or authorized Government inspector that presents an immediate danger to personnel or threatens to impair the mission of the facility. A mechanic shall be on the site ready to service the medical gas, compressed air, and vacuum systems within two (2) hours of receiving a request for emergency service call, 24 hours a day, 7 days a week.  After receiving a request for emergency service, the work shall be prosecuted continuously until the emergency is arrested.\n\nUrgent Repairs: An urgent repair shall be defined as one in which the medical gas, compressed air and vacuum system may become inoperable due to malfunction or need for servicing or threatens to impair the mission of the facility.  A mechanic shall be on the site to service the medical gas, compressed air, and vacuum systems within four (4) hours of receiving a request for urgent service, the work shall be prosecuted continuously until the urgent situation is arrested. Examples of urgent repairs includes: Medical gas system leaking seeping or weeping, power fluctuation affecting the system, or medical gas system no longer functioning. \n\nSystem shut down/standby: The government may direct the contractor to shut down the system at its convenience to allow other Government or contract work to be performed in that area.  The contractor shall be available 24 hours a day, seven days a week.  The Government will provide the contractor with a 24-hour notice of shut down service. At such time, the contractor will be provided the time and date of the shutdown, to include when the equipment will be back to operating status.  The contractor is not required to be at the job site during the period the system is shutdown.  The Contractor will be compensated for the actual time it takes to shut down the system and the actual time it takes to turn-on the system.  Standby requires the Contractor to be at the job site during specified periods, as directed by the COR.  Standby may be required when system is shutdown or when other work (i.e. construction, electrical outages, etc.) may adversely affect the system.  The Contractor will be compensated for the entire standby period.","origin":"detail"},"contacts":[{"name":"Stephanie Decker","role":"primary","email":"Stephanie.Decker2@va.gov","phone":"716-862-7461","title":"Contract Specialist"}],"place_of_performance":{"zip":"12208","city":{"code":"1000","name":"Albany"},"state":{"code":"NY","name":"New York"},"street":"Department of Veteran Affairs Albany VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"113 Holland Ave"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["811210"],"award":{"awardee":{}},"attachments":[{"resource_id":"3c1619cfa29445bf89695702e2a75247","name":"36C24227Q0103.docx","kind":"file","mime_type":".docx","size_bytes":41436,"posted_at":"2026-11-03T20:58:53.973Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3c1619cfa29445bf89695702e2a75247/download","mirrored":false}],"awards":[],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"36C24227Q0136","latest_notice_id":"5ab20ea53d054fd8af4016f010a48827","title":"J065--FY27 SERVICES (BASE+4) Surgical Instrument Repair Services SPS VA NYHHS (VA-27-00005978)","solicitation_number":"36C24227Q0136","notice_type":"o","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-17T15:00:00Z","due_date":"2026-12-17","closes_at":"2026-12-17T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"811210","psc":"J065","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"RFQ24627Q0002","latest_notice_id":"e05660a6946c41cbbef2606eb5b24b46","title":"Full-service maintenance, inspection, calibration, and repair of a body plethysmograph system","solicitation_number":"RFQ24627Q0002","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H721","office_name":"LAWTON INDIAN HOSPITAL","naics":"811210","psc":"J065","set_aside":"SBA","state":"OK","county":"40031","county_name":"Comanche County","city":"4041850","city_name":"Lawton","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"75N98027Q00080","latest_notice_id":"046af05910ad4f4092a269aefe7c0850","title":"Preventive Maintenance Service - GE TracerLab","solicitation_number":"75N98027Q00080","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T14:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"811210","psc":"J066","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open_total":59,"indexable":true}