Sources sought
EQUIPMENT - INFUSION DEVICE ANALYZER
36C24226Q0610
Department of Veterans Affairs, 242-Network Contract Office 02. Electromedical and Electrotherapeutic Apparatus Manufacturing.
Response deadline
May 27, 2026 at 4:00 PM EDT
Closed 182 days ago. Posted May 12, 2026, first published May 11, 2026. Scheduled to archive May 26, 2026.
Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities
This one closed in 2026
12 like it are open now in electromedical and electrotherapeutic apparatus manufacturing
- Vital Signs Monitoring and Physical Assessment Units
Indian Health Service, Indian Health Service
Sources soughtNAICS 334510Ship to Salem, ORREQT-IHS-2026-00220Due tomorrowNov 26 - NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq
National Institutes of Health, National Institutes of Health Olao
Combined synopsis and solicitationNAICS 334510Ship to the buyer75N98027Q00094Due in 2 daysNov 27 - Medtronic FT10 Series Cauterizer
Department of Veterans Affairs, Network Contract Office 23
Combined synopsis and solicitationSDVOSBNAICS 334510Ship to Fargo, ND36C26327Q0131Due in 5 daysNov 30
All 12 open in electromedical and electrotherapeutic apparatus manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334510 (electromedical and electrotherapeutic apparatus manufacturing), means no more than 1,250 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of May 11, 2026. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
THIS REQUEST FOR INFORMATION (RFI)/SOURCES SOUGHT IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES ONLY AND DOES NOT CONSTITUTE A SOLICITATION. THE SUBMISSION OF PRICING, CAPABILITIES FOR PLANNING PURPOSES, AND OTHER MARKET INFORMATION IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI IN ACCORDANCE WITH (IAW) FAR 12. DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 12, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI. SOURCES SOUGHT DESCRIPTION This is NOT a solicitation announcement. This is a sources sought/RFI only. The purpose of this sources sought/RFI is to gain knowledge of potential qualified sources and their size classification relative to NAICS 334510- Electromedical and Electrotherapeutic Apparatus Manufacturing (size standard of 1,250 Employees). Responses to this sources sought will be used by the Government to make appropriate acquisition decisions. After review of the responses to this sources sought, a solicitation announcement may be published. Responses to this sources sought synopsis are not considered adequate responses for a solicitation announcement. The Department of Veterans Affairs (VA), VISN 02 Network Contracting Office, is seeking sources that can provide Infusion Device Analyzer that at a minimum meet the following salient characteristics for the Hudson Valley Healthcare System: To Be Delivered to: VA Hudson Valley Medical Center Castle Point Campus 41 Castle Point Road Wappingers Falls, NY 12590 The VA has a preference for domestic (manufactured in the United States) content where available. Salient Characteristics: Workflow Automation: Integrated OneQA software for automated testing and documentation. Multi-Channel Testing: Ability to test up to four infusion pumps simultaneously. Accuracy & Resolution: Flow range: 0 3000 mL/h (steady), 0 1500 mL/h (peristaltic). Flow accuracy: ±(1% + 0.005 mL/h) at <500 mL/h; otherwise ±2%. Volume range: 0 100,000 mL; resolution 0.001 mL. Occlusion Testing: Peak pressure range -200 to +2600 mmHg; accuracy ±(1% + 5 mmHg). Bolus & PCA Verification: Supports bolus flow and volume testing. Compliance: Meets IEC60601-2-24 and IEC61010-1 standards. User Interface: Large 10-inch touchscreen with intuitive controls. Connectivity: USB-C for PC communication; wireless capability for field testing. Data Storage: >10,000 measurements; ability to upload pictures and instructions. Dimensions & Weight: Approx. 95 mm × 210 mm × 260 mm; weight ~3.8 kg. Power: 19 V DC, 3 A. The information identified above is intended to be descriptive, not restrictive and to indicate the quality of the supplies/services that will be satisfactory. It is the responsibility of the interested source to demonstrate to the government that the interested parties can provide the supplies/services that fulfill the required specifications. If you are interested and are capable of providing the sought out supplies/services, please provide the requested information as well as the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions: Please indicate the size status and representations of your business, such as but not limited to: Service Disabled Veteran Owned Small Business (SDVOSB), Veteran Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.)? (2) Is your company considered small under the NAICS code identified under this RFI? (3) Are you the manufacturer, distributor, or an equivalent solution to the items being referenced above? (4) If you are a large business, do you have any designated distributors? If so, please provide their company name, telephone, point of Contact and size status (if available). (5) If you re a small business and you are an authorized distributor/reseller for the items identified above or an equivalent solution, do you alter; assemble; modify; the items requested in any way? If you do, state how and what is altered; assembled; modified? (6) If you intend to sub contract any work on this contract, what portion of the total cost will be self-performed/will be performed by your organization? Please provide estimated detailed percentage breakdowns related to sub contracted work and completion of job. (7) Does your company have an FSS contract with GSA or the NAC or are you a contract holder with NASA SEWP or any other federal contract? If so, please provide the contract number. (8) If you are an FSS GSA/NAC or NASA SEWP contract holder or other federal contract holder, are the items/solution you are providing information for available on your schedule/contract? (9) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate any type of award. (10) Please submit your capabilities in regard to the salient characteristics being provided and any information pertaining to equal to items to establish capabilities for planning purposes? (11) Will the items you will be providing manufactured domestically in the United States or are they foreign manufactured items? (12) Please review salient characteristics/statement of work (if applicable) and provide feedback or suggestions. If none, please reply as N/A. (13) Please provide your Sam.gov Unique Entity ID number. Responses to this notice shall be submitted via email to Sanchez.Reid@va.gov. Telephone responses shall not be accepted. Responses must be received no later than May 27,2026 at 4:00PM EST. If a solicitation is issued it shall be announced at a later date, and all interested parties must respond to that solicitation announcement separately from the responses to this sources sought. Responses to this sources sought notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation.
Attachments
Links the agency listed on SAM.gov. They open the sites it named, not files on SAM.gov.
- va.govLink, May 11, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
May 11, 2026
Sources sought
Due May 21, 2026 at 4:00 PM EDT. SAM.gov, notice 12ae0fa7f8894d299ffc35802e9661fc
2 revisions on SAM
- May 13, 2026: publish, sources sought
- May 11, 2026: publish, sources sought
May 13, 2026
Sources sought
Due May 27, 2026 at 4:00 PM EDT. SAM.gov, notice 07a2c88c272543eb8a600d7f2d5b3441
2 revisions on SAM
- May 13, 2026: publish, sources sought
- May 11, 2026: publish, sources sought
Points of contact
- Sanchez Reid, Contract SpecialistSanchez.Reid@va.gov908-647-0180 x214466