{"canonical":"https://sealedbidder.com/opportunities/36c24226q0220","key":"36C24226Q0220","url":"https://sealedbidder.com/opportunities/36c24226q0220","title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","solicitation_number":"36C24226Q0220","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-01-02T18:00:00Z","first_posted":"2025-12-16","last_posted":"2025-12-23","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Z1DA","set_aside":null,"place_state":"NY","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"36001","place_county_name":"Albany County","place_city":"3601000","place_city_name":"Albany","winner":"IRON SWORD ENTERPRISES, LLC","award_amount":null,"publications":[{"notice_id":"adff049e6c374adbb8888540ea704ec3","title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","solicitation_number":"36C24226Q0220","notice_type":"o","base_type":"p","posted":"2025-12-16","posted_at":"2025-12-16T21:02:24.056Z","due_at":"2025-12-31T18:00:00Z","due_date":"2025-12-31","cancelled":false,"archived":true,"archive_date":"2026-03-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/adff049e6c374adbb8888540ea704ec3/view","enriched":true,"history":[{"index":6,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:01:21.797Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"eade96c3df684f0b8f63d8e475258adc","solicitation_number":"36C24226Q0220"},{"index":5,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-23T19:18:32.614Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"447aaffdecde4e1a95cd6612c486861f","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":3,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-22T19:42:53.477Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"199f4aeebba84def98a20c343586d71a","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":2,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:02:24.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"adff049e6c374adbb8888540ea704ec3","solicitation_number":"36C24226Q0220","related_opportunity_id":"eade96c3df684f0b8f63d8e475258adc"}]},{"notice_id":"eade96c3df684f0b8f63d8e475258adc","title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","solicitation_number":"36C24226Q0220","notice_type":"p","base_type":"p","posted":"2025-12-16","posted_at":"2025-12-16T21:01:21.797Z","due_at":"2025-12-15T18:00:00Z","due_date":"2025-12-15","cancelled":false,"archived":true,"archive_date":"2026-03-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/eade96c3df684f0b8f63d8e475258adc/view","enriched":true,"history":[{"index":4,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:01:21.797Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"eade96c3df684f0b8f63d8e475258adc","solicitation_number":"36C24226Q0220"},{"index":2,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:02:24.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"adff049e6c374adbb8888540ea704ec3","solicitation_number":"36C24226Q0220","related_opportunity_id":"eade96c3df684f0b8f63d8e475258adc"}]},{"notice_id":"199f4aeebba84def98a20c343586d71a","title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","solicitation_number":"36C24226Q0220","notice_type":"o","base_type":"o","posted":"2025-12-22","posted_at":"2025-12-22T19:42:53.477Z","due_at":"2025-12-26T18:00:00Z","due_date":"2025-12-26","cancelled":false,"archived":true,"archive_date":"2026-01-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/199f4aeebba84def98a20c343586d71a/view","enriched":true,"history":[{"index":4,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-23T19:18:32.614Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"447aaffdecde4e1a95cd6612c486861f","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":2,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-22T19:42:53.477Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"199f4aeebba84def98a20c343586d71a","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":1,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:02:24.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"adff049e6c374adbb8888540ea704ec3","solicitation_number":"36C24226Q0220","related_opportunity_id":"eade96c3df684f0b8f63d8e475258adc"}]},{"notice_id":"447aaffdecde4e1a95cd6612c486861f","title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","solicitation_number":"36C24226Q0220","notice_type":"o","base_type":"o","posted":"2025-12-23","posted_at":"2025-12-23T19:18:32.614Z","due_at":"2026-01-02T18:00:00Z","due_date":"2026-01-02","cancelled":false,"archived":true,"archive_date":"2026-02-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/447aaffdecde4e1a95cd6612c486861f/view","enriched":true,"history":[{"index":4,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-23T19:18:32.614Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"447aaffdecde4e1a95cd6612c486861f","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":2,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-22T19:42:53.477Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"199f4aeebba84def98a20c343586d71a","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":1,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:02:24.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"adff049e6c374adbb8888540ea704ec3","solicitation_number":"36C24226Q0220","related_opportunity_id":"eade96c3df684f0b8f63d8e475258adc"}]}],"latest_notice_id":"447aaffdecde4e1a95cd6612c486861f","first_type":"o","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-12-16","posted_at":"2025-12-16T21:02:24.056Z","created_at":"2025-12-16T21:02:11.503Z","modified_at":"2026-02-02T04:55:43.495Z","response_deadline":{"raw":"2025-12-31T13:00:00-05:00","utc":"2025-12-31T18:00:00Z","date":"2025-12-31","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/adff049e6c374adbb8888540ea704ec3/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-31","archive_type":"auto_custom"},"history":[{"index":6,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:01:21.797Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"eade96c3df684f0b8f63d8e475258adc","solicitation_number":"36C24226Q0220"},{"index":5,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-23T19:18:32.614Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"447aaffdecde4e1a95cd6612c486861f","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":3,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-22T19:42:53.477Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"199f4aeebba84def98a20c343586d71a","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":2,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:02:24.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"adff049e6c374adbb8888540ea704ec3","solicitation_number":"36C24226Q0220","related_opportunity_id":"eade96c3df684f0b8f63d8e475258adc"}],"contacts":[{"name":"Terry Fraser","role":"primary","email":"terry.fraser@va.gov","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"adff049e6c374adbb8888540ea704ec3","lineage_id":"adff049e6c374adbb8888540ea704ec3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-19T01:02:18.539654618Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"ca440727def1e5e76ec5b8bec0f5b11cf55c7d27aa0085948d33543eaec8b3bd","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-19T01:02:18.539654618Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"FURNISH & INSTALL ENTRANCE/SECURITY DOORS at 10C, 9D & 8C ALBANY VAMC","text":"FURNISH & INSTALL ENTRANCE/SECURITY DOORS at 10C, 9D & 8C ALBANY VAMC","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24226Q0220","product_service_code":"Z1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-12-16","posted_at":"2025-12-16T21:01:21.797Z","created_at":"2025-12-16T21:01:19.627Z","modified_at":"2026-03-16T04:00:07.220Z","response_deadline":{"raw":"2025-12-15T13:00:00-05:00","utc":"2025-12-15T18:00:00Z","date":"2025-12-15","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/eade96c3df684f0b8f63d8e475258adc/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-15","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:01:21.797Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"eade96c3df684f0b8f63d8e475258adc","solicitation_number":"36C24226Q0220"},{"index":2,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:02:24.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"adff049e6c374adbb8888540ea704ec3","solicitation_number":"36C24226Q0220","related_opportunity_id":"eade96c3df684f0b8f63d8e475258adc"}],"contacts":[{"name":"Terry Fraser","role":"primary","email":"terry.fraser@va.gov","phone":"(585) 926-5000","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"eade96c3df684f0b8f63d8e475258adc","lineage_id":"adff049e6c374adbb8888540ea704ec3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-19T01:24:33.649719167Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"649ce7ca8c44ae5c17f7a64977e68afff17d637ac8e8ab1810d98a08ce9263b9","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-19T01:24:33.649719167Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"Page 2 of 2\nPRE-SOLICITATION NOTICE \nTHIS PRE-SOLICITATION NOTICE IS TO INFORM YOU THAT THE STRATTON VA MEDICAL CENTER, LOCATED AT 113 HOLLAND AVE, ALBANY, NY 12208 WILL BE POSTING A SOLICITATION ON OR ABOUT DECEMBER 2, 2025, FOR THE ALBANY VAMC FURNISH & INSTALL ENTRANCE/SECURITY DOORS AT 8C, 9D & 10C PROJECT.\nThe Stratton VA Medical Center (VAMC) located at 113 Holland Avenue, Albany, New York is requesting a contract to provide all labor and materials to furnish, install and rework Security/Entrance doors at the following location:\n8C: New Gypsum Wall Board (GWB) wall with swinging wood double doors with vison lights \n& access control.\n9D: Relocate storefront door system from 10D and add missing door to system. \n10C: Existing storefront door with side light system, must have door with opposite swing.  New door inset to be provided. New window film to be included.\n\nThis procurement will be a 100% set-aside for Service Disabled Veteran Owned Small Businesses.  The NAICS code is 236220. The small business standard is $45.0 Million. The magnitude of construction per FAR Part 36.204 is between $25,000 and $100,000.  \nSolicitation materials consisting of the Information for Bid Details, Specifications, Drawings and Contract Forms will be available on beta.SAM.gov in electronic format only.  \nThe POC for this project will be Terry Fraser and can be reach at email at terry.fraser@va.gov.","text":"Page 2 of 2\nPRE-SOLICITATION NOTICE\nTHIS PRE-SOLICITATION NOTICE IS TO INFORM YOU THAT THE STRATTON VA MEDICAL CENTER, LOCATED AT 113 HOLLAND AVE, ALBANY, NY 12208 WILL BE POSTING A SOLICITATION ON OR ABOUT DECEMBER 2, 2025, FOR THE ALBANY VAMC FURNISH & INSTALL ENTRANCE/SECURITY DOORS AT 8C, 9D & 10C PROJECT.\nThe Stratton VA Medical Center (VAMC) located at 113 Holland Avenue, Albany, New York is requesting a contract to provide all labor and materials to furnish, install and rework Security/Entrance doors at the following location:\n8C: New Gypsum Wall Board (GWB) wall with swinging wood double doors with vison lights\n& access control.\n9D: Relocate storefront door system from 10D and add missing door to system.\n10C: Existing storefront door with side light system, must have door with opposite swing. New door inset to be provided. New window film to be included.\n\nThis procurement will be a 100% set-aside for Service Disabled Veteran Owned Small Businesses. The NAICS code is 236220. The small business standard is $45.0 Million. The magnitude of construction per FAR Part 36.204 is between $25,000 and $100,000.\nSolicitation materials consisting of the Information for Bid Details, Specifications, Drawings and Contract Forms will be available on beta.SAM.gov in electronic format only.\nThe POC for this project will be Terry Fraser and can be reach at email at terry.fraser@va.gov.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24226Q0220","product_service_code":"Z1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-12-22","posted_at":"2025-12-22T19:42:53.477Z","created_at":"2025-12-22T19:42:50.904Z","modified_at":"2026-02-02T04:55:43.495Z","response_deadline":{"raw":"2025-12-26T13:00:00-05:00","utc":"2025-12-26T18:00:00Z","date":"2025-12-26","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/199f4aeebba84def98a20c343586d71a/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-01-25","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-23T19:18:32.614Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"447aaffdecde4e1a95cd6612c486861f","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":2,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-22T19:42:53.477Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"199f4aeebba84def98a20c343586d71a","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":1,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:02:24.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"adff049e6c374adbb8888540ea704ec3","solicitation_number":"36C24226Q0220","related_opportunity_id":"eade96c3df684f0b8f63d8e475258adc"}],"contacts":[{"name":"Terry Fraser","role":"primary","email":"terry.fraser@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"199f4aeebba84def98a20c343586d71a","lineage_id":"adff049e6c374adbb8888540ea704ec3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-18T02:20:10.274963287Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"dbab5c0fa7c107c786ad0c377ff4801c740664193930bd1603158787a8df7aec","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-18T02:20:10.274963287Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"Stratton VA Medical Center \nAlbany, New York \nStatement of Work (SOW)\nFURNISH & INSTALL ENTRANCE/\nSECURITY DOORS at 10C & 9D\n\nGeneral Scope of Work: Stratton Veterans Administration Medical Center, located at 113 Holland Avenue, Albany NY 12208 is requesting a contract to provide all labor and materials to furnish, install and rework Security/Entrance doors at the following location:\n10C: Existing storefront door with side light system, must have door with opposite swing.  New door inset to be provided. New window film to be included.\n9D: Relocate storefront door system from 10D and add missing door to system. \nWork Required:\n9D\nRelocate existing storefront sidelight system from 10C to 9D and add door to system.\n\nContractor will provide all materials, labor and travel to relocate existing storefront door system from 10C to 9D.\nContractor will provide all materials, labor and travel to return the 10D walls and flooring to original by matching existing finishes upon removal of storefront system.\n10C\nContractor will provide all materials, labor and travel to provide NEW storefront door (from Right Hand Reverse(RHR) to Left Hand Reverse (LHR). \nContractor will provide all materials, labor and travel to install NEW hardware and door to LHR swing door.\nExisting door hardware includes:\nFour heavy duty ball bearing butt hinges.\nPush side Von Duprin 99 rim exit device with quiet latch retraction (QEL).\nPush side request to exit with jamb mounted strike.\nPush side Nabco GT 710 low energy operator bronze finish.\nPull side bronze finish thought bolted wire pull handle with cylinder hole.\n\nContractor will provide all materials, labor and travel required to adapt existing access control system to a LHR swing door system.\nContractor will provide all materials, labor and travel required to install new window film as indicated in attached photos.\nVendor will be required to confirm all measurements on-site. \n\nProvided by VA:\n115VAC power above ceiling for operator & exit device power supply\nAll required relocations of sprinkler heads\nVA Police Physical Security will provide port and address information for programming the system into the existing Lenel platform\n\nThe following is required for this contract:\nAll work will be in accordance with:\nNFPA 72: National Fire Alarm and Signaling Code. \nNFPA 70E: Standard for Electrical Safety in the Workplace.\nNFPA 70: National Electrical Code    Articles 517, 645 & 800.\nNFPA 77: Recommended Practice on Static Electricity.\nNFPA 99: Healthcare Facilities.\nNFPA 101: Life Safety Code.\nPeriod of Performance\nOne (1) Week after contract award- Submittals due.\nOne (1) Week-Required submittal review.\nOne (1) Week after all materials arrive- Work starts\nOne (1) Week-To complete work.\nTOTAL Four (4) Weeks plus material lead time. \n\nAttachments:\nDoor sample and placement.\nDoor locations.\nAluminum Door Spec.\nGlazing Spec.\n\n\n\n\n\nLocation of Door on 9D Relocated from 10C\n\n\n\n\n\n\n10C WINDOW FILM SAMPLE\n\n\n\n\n\n\n\n\n\nSECTION 08 44 13\nGLAZED ALUMINUM CURTAIN WALLS\n\nGENERAL\nDESCRIPTION:\nThis section specifies glazed aluminum curtain wall system.\nThermally isolated, pressure equalized on interior.\nType: Unit and Mullion system to include following:\nUninsulated Metal Panels.\nClosures, trim, subsills and flashings.\nColumn covers.\nFasteners, anchors, and related reinforcement.\nRELATED WORK:\nGlazing: Section 08 80 00, GLAZING.\nQUALITY ASSURANCE: \nQualifications:\nApproval by Contracting Officer Representative (COR) is required of products or services of proposed manufacturer, suppliers and installers, and will be based upon submission by Contractor of certification that: \nManufacturers Qualifications: Manufacturer with five (5) years continuous documented experience in fabrication, of glazed aluminum curtain wall systems of similar types and for projects of equivalent size. \nInstaller: Manufacturer approved in writing who has continuously installed glazed aluminum curtain walls systems of similar types and for projects of equivalent size for previous five (5) years.\n\nDELIVERY, STORAGE AND HANDLING:\nRefer to AAMA CW 10 for care and handling of architectural aluminum from shop to site.\nPrior to packaging for shipment from factory, mark wall components to correspond with shop and erection drawings and their placement location and erection sequence.\nPrior to shipment from factory, place knocked down lineal curtain wall members in cardboard containers and cover finished surfaces of members with protective covering of adhesive paper, waterproof tape, or strippable plastic. Do not cover metal surfaces that will be in contact with sealants after installation.\nPROJECT CONDITIONS:\nField Measurements: Where glazed aluminum curtain wall systems are indicated to fit to other construction, verify dimensions of other construction by field measurements before fabrication and indicate measurements on shop drawings. Coordinate fabrication schedule with construction progress to avoid delaying Work.\nAPPLICABLE PUBLICATIONS:  \nPublications listed below form a part of this specification to extent referenced. Publications are referred to in text by basic designation only.\nAmerican Architectural Manufacturers Association (AAMA): \nMCWM-1-89 Metal Curtain Wall Manual\nCW 10-12 Care and Handling of Architectural Aluminum from Shop to Site\nCW 13-85 Structural Sealant Glazing Systems (A Design Guide)\n503-08 Field Testing of Metal Storefronts, Curtain walls and Sloped Glazing Systems\nAmerican Society of Civil Engineers (ASCE):\nASCE 7-10 Minimum Design Loads for Buildings and Other Structures\nASTM International (ASTM): \nA36/A36M-12 Structural Steel\nA123/A123M-13 Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products\nA193/A193M-14a Alloy Steel and Stainless-Steel Bolting Materials for High Temperature Service\nA307-14 Carbon Steel Bolts and Studs, 60,000 PSI Tensile Strength\nB209-14 Aluminum and Aluminum Alloy Sheet and Plate\nB211-12 Aluminum and Aluminum Alloy Bar, Rod, Wire \nB221-14 Aluminum and Aluminum Alloy Extruded Bars, Rods, Wire, Shapes and Tubes\nB316/B316M-10 Aluminum and Aluminum Alloy Rivet and Cold-Heading, Wire, and Rods\nC578-14a Rigid Cellular Polystyrene Thermal Insulation\nC920-14a Elastomeric Joint Sealants\nC794-10 Standard Test Method for Adhesion-In-Peel of Elastomeric Joint Sealants.\nC1193-13 Guide for Use of Joint Sealants \nC1363-11 Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus\nC1521-13 Practice for Evaluating Adhesion of Installed Weatherproofing \nE84-14 Surface Burning Characteristics of Building Materials\nE413-10 Classification for Rating Sound Insulation\nAmerican Welding Society, Inc. (AWS): \nD1.2/D.1.2M-06(R2014) Structural Welding Code Aluminum\nNational Association of Architectural Metal Manufacturers (NAAMM):\n500 Series (2006) Metal Finishes Manual\nSociety for Protective Coatings (SSPC)\nPaint 25-97 (2004) Zinc Oxide, Alkyd, Linseed Oil Primer for Use Over Hand Cleaned Steel Type 1 and Type II\nPaint 20-82 (2019) Zinc-Rich Coating, Type I-Inorganic, and Type II-Organic.\nU.S. Veterans Administration:\nPhysical Security Design Manual for VA Facilities (VAPSDG); Life Safety Protected\nArchitectural Design Manual for VA Facilities (VASDM)\nEnvironmental Protection Agency (EPA):\n40 CFR 59(2014) National Volatile Organic Compound Emission Standards for Consumer and Commercial Products\nWARRANTY:\nConstruction Warranty: Comply with FAR clause 52.246-21,  Warranty of Construction . \n  \nPRODUCTS\nSYSTEM DESCRIPTION:\nDesign Requirements:\nShop unitized assembly.Â  \n Maximum wall framing member deflection, in a direction normal to plane of wall: 1/175 of its clear span or 20 mm (3/4 inch), whichever is less, when designed in accordance with requirements of AAMA TIR A11 and tested in accordance with ASTMÂ E330/E330M.\nMaximum wall framing member deflection when a gypsum wallboard surface is affected: 1/360 of span. \nMaximum Framing Member Permanent Deformation: 0.2 percent of its clear span when tested in accordance with ASTM E330/E330M for a minimum test period of 10 seconds at 1.5 times design wind pressures indicated as part of structural drawing wind load requirements. \nNo glass breakage, or damage to fasteners, hardware or accessories is permitted due to deformation design requirements indicated.\nProvide system complete with framing, mullions, trim, fasteners, anchors, accessories, concealed auxiliary members, and attachment devices for securing wall to structure as specified or indicated. Unless noted otherwise, comply with AAMA MCWM 1.\nObtain all components from single manufacturer.\nFully coordinate system accessories directly incorporated and adjacent to contiguous related work and ensure materials compatibility, deflection limitations, thermal movements, and clearances and tolerances as indicated or specified. Coordinate continuity with adjacent thermal, weather, air and vapor barriers.\nProvide system with adequate allowances for expansion and contraction of components and fastenings to prevent buckling damage, joint seal failure, glass breakage, undue stress on fastening or other detrimental effects. For design purposes, base provisions for thermal movement on assumed ambient temperature range of from  18 degrees C to 49 degrees C (0 degrees F to 120 degrees F).\nProvide wall system to accommodate tolerances in building frame and other contiguous work as indicated or specified.\n\nMATERIALS:\nExtruded Aluminum Framing Members: ASTM B221M (B221); 6063-T5 extruded aluminum for non-structural components or 6063-T6 extruded aluminum for structural members; temper and alloy as recommended by manufacturer.\nSheet Aluminum: ASTM B209M (B209); 6065-T5 temper and alloy as recommended by manufacturer. \n Formed flashing and closures: Minimum 1.58 mm (0.062 inch) thick aluminum, in finish as selected. \n Extruded sill members: Minimum 1.58 mm (0.062 inch) thick aluminum, in finish as selected.\nFasteners:\nFor Framework Connections: ASTM B211M (B211) 2024 T4 aluminum, ASTMÂ A193/A193M B8 300 series, stainless steel, and ASTM B316 aluminum rivets, as required by connection.\nFor Anchoring Glazed Aluminum Curtain Wall to Support Structure: ASTM A307 zinc plated steel fasteners.\nShims: Metal or plastic.\nGlazing Materials:\n As specified under Section 08 80 00, GLAZING.\n Glazing Gaskets: Interior: Continuous, closed cell PVC foam sealant tape, sealed at corners.\n Glass Sizes and Clearances:\nAccommodate up to 1/4-inch glazing.\nSizes indicated are nominal. Verify actual sizes required by measuring frames. Coordinate dimensions for glass and glass holding members to meet applicable minimum clearances as recommended by glass manufacturers. Do not nip glass to remove flares or to reduce oversized dimensions. All cutting is to occur in factory.\n Glass Setting Materials:\nProvide head bead and drive wedge required for glass installation to suit curtain wall system in accordance with manufacture s recommendations.  \nFABRICATION:\nCurtain wall components are to be of materials and thickness indicated in construction documents. Details indicated are representative of required design and profiles. Maintain sightlines. Unless specifically indicated or specified otherwise, methods of fabrication and assembly are to be at discretion of curtain wall manufacturers. Perform fitting and assembling of components in shop to maximum extent practicable. Anchorage devices are to permit adjustment in three directions. No exposed fasteners are permitted. \nJoints: Joints exceeding +1.5 mm (+1/16\") are to be mechanically fastened. \nProtection and Treatment of Metals:\n Remove from metal surfaces lubricants used in fabrication and clean off other extraneous material before leaving shop.\nProvide protection against galvanic action wherever dissimilar metals are in contact, except in case of aluminum in permanent contact with galvanized steel, zinc, stainless steel, or relatively small areas of white bronze. Paint contact surfaces with one coat bituminous paint conforming to MIL C 18480 or apply appropriate caulking material or nonabsorptive, noncorrosive, and non-staining tape or gasket between contact surfaces.\nMetal sills and Closures: Fabricate accessories, spandrel panels, trim closures of sizes and shapes indicated from similar materials and finish as specified for wall system.\nMETAL FINISHES:\nIn accordance with NAAMM AMP500 series.\nAnodized Aluminum:  \nAA C22A44 Chemically etched medium matte with electrolytically deposited metallic compound, integrally colored coating Class 1 Architectural, 0.7 mil thick finish. Dyes will not be accepted. \nDark bronze.\n \nEXECUTION\nPREPARATION:\nTake field dimensions and examine condition of substrates, supports, and other conditions under which work of this section is to be performed to verify that work may properly commence. Do not proceed with installation until unsatisfactory conditions have been corrected.\nContact between aluminum and dissimilar metals are to receive a protective coating of bituminous paint for prevention of electrolytic action and corrosion.\nINSTALLATION:\nInstall and erect glazed curtain wall system and all components in accordance with written directions of curtain wall manufacturer. Match profiles, sizes, and spacing indicated on approved shop drawings.\nInstall glazed aluminum curtain wall system so as to maintain a virtually flat face cap, with no visible bowing.\nInstall entire system so that fasteners are not visible.\nTolerances:\nMaximum variation from plane or location shown on approved shop drawings: 3 mm per 3657 mm (1/8 inch per 12 feet) of length up to not more than 13 mm (1/2 inch) in any total length.\nMaximum offset from true alignment between two (2) identical members abutting end to end in line: 0.8 mm (1/32 inch).\n Sealant Space Between Curtain Wall Mullion and Adjacent Construction: Maximum of 19 mm (3/4 inch) and minimum of 6 mm (1/4Â inch). \nADJUSTING:\nAdjust doors to provide a tight fit at contact points and operate easily.  \nAdjust weather-stripping to make even contact with surfaces.\nAdjust operating hardware and moving parts. \nCLEANING: \nInstall curtain wall frame and associated metal to avoid soiling or smudging finish.\nClean metal surfaces promptly after installation, exercising care to avoid damage to coatings.\nRemove excess glazing and sealant compounds, dirt, and other substances.\nFollow recommendations of manufacturer in selection of cleaning agents. Do not use cleaning agents containing ammonia or other compounds that might damage finished metal surfaces.\nReplace cracked, broken, and defective glass with new glass at no additional cost to Government. Just prior to final acceptance of curtain wall system clean glass surfaces on both sides, remove labels, paint spots, compounds, and other defacements, and clean metal fixed panels. Remove and replace components that cannot be cleaned successfully. \nDEMONSTRATION, TESTING, AND ACCEPTANCE:\nInstruct Government s personnel in proper operation and maintenance of door equipment. Train personnel in procedures to follow in event of operational failures or malfunctions.  \nAcceptance: At completion of project, and as a condition of acceptance, door and systems are to be operated for a period of fifteen (15) consecutive calendar days without breakdown.  \nPROTECTION:\nAfter installation, protect windows, and other exposed surfaces from disfiguration, contamination, contact with harmful materials, and from other construction hazards that will interfere with their operation, or damage their appearance or finish. Protection methods are to be in accordance with recommendations of product manufacturers or of respective trade association. Remove paper or tape factory applied protection immediately after installation. Clean surfaces of mortar, plaster, paint, smears of sealants, and other foreign matter to present neat appearance and prevent fouling of operation. In addition, wash with a stiff fiber brush, soap and water, and thoroughly rinse. Where surfaces become stained or discolored, clean or restore finish in accordance with recommendations of product manufacturer or respective trade association.\n      END     -\n\n\n\n\n\n\n\nSECTION 08 80 00\nGLAZING\nGENERAL\n DESCRIPTION\nThis section specifies the following:\nGlass. \nGlazing materials and accessories for both factory and field glazed assemblies.\n RELATED WORK\nSection 08 44 13, GLAZED ALUMINUM CURTAIN WALLS Glazed Curtain Walls: Glazed Curtain Walls.\nLABELS\nPermanent labels:\nLocate in corner for each pane.\nLabel in accordance with ANSI Z97.1 and SGCC label requirements.\nTempered glass.\nPERFORMANCE REQUIREMENTS\nGeneral: Design glazing system consistent with guidance and practices presented in the GANA Glazing Manual, GANA Laminated Glazing Manual, and GANA Sealant Manual, as applicable to project. Installed glazing is to withstand applied loads, thermal stresses, thermal movements, building movements, permitted tolerances, and combinations of these conditions without failure, including loss or glass breakage attributable to defective manufacture, fabrication, or installation; failure of sealants or gaskets to remain watertight and airtight; deterioration of glazing materials; unsafe engagement of the framing system; deflections beyond specified limits; or other defects in construction.\nGlazing Unit Design: Design glass, including engineering analysis meeting requirements of authorities having jurisdiction. Thicknesses listed are minimum. Coordinate thicknesses with framing system manufacturers.\nDesign glass in accordance with ASTM E1300, and for conditions beyond the scope of ASTM E1300, by a properly substantiated structural analysis.\nMaximum Lateral Deflection: For glass supported on all four edges, limit center-of-glass deflection at design wind pressure to not more than the structural capacity of the glazing unit, the threshold at which frame engagement is no longer safely assured, 1/100 times the short-side length, or  19 mm (0.75 inch), whichever is less.\nDELIVERY, STORAGE AND HANDLING\nDelivery: Schedule delivery to coincide with glazing schedules so minimum handling of crates is required. Do not open crates except as required for inspection for shipping damage.\nStorage: Store cases according to printed instructions on case, in areas least subject to traffic or falling objects. Keep storage area clean and dry.\nHandling: Unpack cases following printed instructions on case. Stack individual windows on edge leaned slightly against upright supports with separators between each.\nProtect laminated security glazing units against face and edge damage during entire sequence of fabrication, handling, and delivery to installation location. Provide protective covering on exposed faces of glazing plastics, and mark inside as \"INTERIOR FACE\" or \"PROTECTED FACE\":\nTreat security glazing as fragile merchandise and packaged and shipped in export wood cases with width end in upright position and blocked together in a mass. Storage and handling to comply with manufacturer's directions and as required to prevent edge damage or other damage to glazing resulting from effects of moisture, condensation, temperature changes, direct exposure to sun, other environmental conditions, and contact with chemical solvents. \nProtect sealed-air-space insulating glazing units from exposure to abnormal pressure changes, as could result from substantial changes in altitude during delivery by air freight. Provide temporary breather tubes which do not nullify applicable warranties on hermetic seals. \nTemporary protections: The glass front and polycarbonate back of glazing are to be temporarily protected with compatible, peelable, heat-resistant film which will be peeled for inspections and re applied and finally removed after doors and windows are installed at destination. Since many adhesives will attack polycarbonate, the film used on exposed polycarbonate surfaces is to be approved and applied by manufacturer. \nEdge protection: To cushion and protect glass clad, and polycarbonate edges from contamination or foreign matter, the fourÂ (4) edges are to be sealed the depth of glazing with continuous standard thickness thermoplastic rubber tape. Alternatively, continuous channel shaped extrusion of thermoplastic rubber are to be used, with flanges extending into face sides of glazing. \nPROJECT CONDITIONS:\nField Measurements: Field measure openings before ordering tempered glass products to assure for proper fit of field measured products.\n APPLICABLE PUBLICATIONS:\nPublications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only.\nAmerican Architectural Manufacturers Association (AAMA): \n800 Test Methods for Sealants\n810.1-77 Expanded Cellular Glazing Tape\nAmerican National Standards Institute (ANSI):\nZ97.1-14 Safety Glazing Material Used in Building   Safety Performance Specifications and Methods of Test\nASTM International (ASTM):\nC542-05(2017) Lock-Strip Gaskets\nC716-06(2020) Installing Lock-Strip Gaskets and Infill Glazing Materials\nC794-18 Adhesion-in-Peel of Elastomeric Joint Sealants\nC864-05(2019) Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers\nC920-18 Elastomeric Joint Sealants\nC964-20 Standard Guide for Lock-Strip Gasket Glazing\nD635-18 Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastic in a Horizontal Position\nE84-20 Surface Burning Characteristics of Building Materials\nE119-20 Standard Test Methods for Fire Test of Building Construction and Material\nE1300-16 Load Resistance of Glass in Buildings\nF1233-08(2019) Standard Test Method for Security Glazing Materials and Systems\nF1642/F1642M-17 Test Method for Glazing and Glazing Systems Subject to Airblast Loadings\nCode of Federal Regulations (CFR):\n16 CFR 1201-10 Safety Standard for Architectural Glazing Materials\nGlass Association of North America (GANA):\n2010 Edition GANA Glazing Manual\n2008 Edition GANA Sealant Manual\n2010 Edition GANA Protective Glazing Reference Manual\nInternational Code Council (ICC):\nIBC International Building Code\nIntertek Testing Services   Warnock Hersey (ITS-WHI)\nNational Fire Protection Association (NFPA):\n80-16 Fire Doors and Windows\n252-12 Fire Tests of Door Assemblies\nNational Fenestration Rating Council (NFRC)\nSafety Glazing Certification Council (SGCC) 2012:\n Certified Products Directory (Issued Semi-Annually).\nUnderwriters Laboratories, Inc. (UL):\n9-08(R2009) Fire Tests of Window Assemblies\n263-14 Fire Tests of Building Construction and Materials\nDepartment of Veterans Affairs:\nArchitectural Design Manual for VA Facilities (VASDM)\n\nPRODUCT\n\n GLASS\nProvide minimum thickness stated and as additionally required to meet performance requirements.\nProvide minimum 6 mm (1/4 inch) thick glass units unless otherwise indicated.\nObtain glass units from single source from single manufacturer for each glass type.\nClear Glass:\nASTM C1036, Type I, Class 1.\n\n GLAZING ACCESSORIES\nAs required to supplement the accessories provided with the items to be glazed and to provide a complete installation. Ferrous metal accessories exposed in the finished work are to have a finish that will not corrode or stain while in service. Fire rated glazing to be installed with glazing accessories in accordance with the manufacturer s installation instructions.\nSpacers: ASTM C864:\nChannel shape having a 6 mm (1/4 inch) internal depth.\nFlanges not less 2.4 mm (3/32 inch) thick and web 3 mm (1/8 inch) thick.\nLengths: 25 to 76 mm (1 to 3 inches).\nShore A hardness of 40 to 50 Durometer.\nGlazing Tapes:\nSemi solid polymeric based closed cell material exhibiting pressure sensitive adhesion and withstanding exposure to sunlight, moisture, heat, cold, and aging.\nShape, size and degree of softness and strength suitable for use in glazing application to prevent water infiltration.\nComplying with AAMA 800 for the following types:\nAAMA 810.1, Type 1, for glazing applications in which tape acts as the primary sealant.\nAAMA 810.1, Type 2, for glazing applications in which tape is used in combination with a full bead of liquid sealant.\nSpring Steel Spacer: Galvanized steel wire or strip designed to position glazing in channel or rabbeted sash with stops.\nGlazing Clips: Galvanized steel spring wire designed to hold glass in position in rabbeted sash without stops.\nGlazing Points (Sprigs): Pure zinc stock, thin, flat, triangular or diamond shaped pieces, 6 mm (1/4 inch) minimum size.\nGlazing Gaskets: ASTM C864:\nFirm dense wedge shape for locking in sash.\nSoft, closed cell with locking key for sash key.\nFlanges may terminate above the glazing beads or terminate flush with top of beads.\n\nEXECUTION\n EXAMINATION\nVerification of Conditions:\nExamine openings for glass and glazing units; determine they are proper size; plumb; square; and level before installation is started.  \nVerify that glazing openings conform with details, dimensions and tolerances indicated on manufacturer is approved shop drawings.\nReview for conditions which may adversely affect glass and glazing unit installation, prior to commencement of installation. Do not proceed with installation until unsatisfactory conditions have been corrected.\nVerify that wash down of adjacent masonry is completed prior to erection of glass and glazing units.\n PREPARATION\nFor sealant glazing, prepare glazing surfaces in accordance with GANAÂ Sealant Manual.\nDetermine glazing unit size and edge clearances by measuring the actual unit to receive the glazing.\nShop fabricate and cut glass with smooth, straight edges of full size required by openings to provide GANA recommended edge clearances.\nVerify that components used are compatible.\nClean and dry glazing surfaces.\nPrime surfaces scheduled to receive sealants, as determined by preconstruction sealant-substrate testing.\n INSTALLATION   GENERAL\nInstall in accordance with GANA Glazing Manual, GANA Sealant Manual, IGMA TB-3001, and IGMA TM-3000 unless specified otherwise.\nGlaze in accordance with recommendations of glazing and framing manufacturers, and as required to meet the Performance Test Requirements specified in other applicable sections of specifications.\nSet glazing without bending, twisting, or forcing of units.\nDo not allow glass to rest on or contact any framing member.\nGlaze doors and operable sash, in a securely fixed or closed and locked position, until sealant, glazing compound, or putty has thoroughly set.\nTempered Glass: Install with roller distortions in horizontal position unless otherwise directed.\n INSTALLATION   INTERIOR WET/DRY METHOD (TAPE AND SEALANT)\nCut glazing tape to length and install against permanent stops, projecting 1.6 mm (1/16 inch) above sight line.\nPlace setting blocks at 1/4 points with edge block no more than 150 mm (6 inches) from corners.\nRest glazing on setting blocks and push against tape to ensure full contact at perimeter of pane or unit.\nInstall removable stops, spacer shims inserted between glazing and applied stops at 600 mm (24 inch) intervals, 6 mm (1/4 inch) below sight line.\nFill gaps between pane and applied stop with sealant to depth equal to bite on glazing, to uniform and level line. Sealant type is to be compatible with glazing tape.\nTrim protruding tape edge.\n REPLACEMENT AND CLEANING\nClean new glass surfaces removing temporary labels, paint spots, and defacement after approval by COR.\nReplace cracked, broken, and imperfect glass, or glass which has been installed improperly.\nLeave glass, putty, and other setting material in clean, whole, and acceptable condition. \n PROTECTION\nProtect finished surfaces from damage during erection, and after completion of work. Strippable plastic coatings on colored anodized finish are not acceptable.\n\nAutodesk Build Construction Management Platform \n\n\nAutodesk build construction management platform:\nThe Contractor shall utilize VISN 2 Autodesk Build Construction management platform, also called Autodesk Construction Cloud (ACC). \nAccess to the platform and training portal will be provided by VISN 2 through project Contracting Officer Representative (COR) at no cost for the duration of the project. Autodesk Build is the management and collaborative environment that VISN 2 uses for all its Non-Recurring Maintenance (NRM), Minor Program projects, Feasibility Studies, Commissioning and Retro-Commissioning contracts.  There is no user, license, or subscription fee to the contractor for using this cloud-based platform. \nThe Contractor shall accomplish and complete the following tasks upon award of contract:\nRequest access to ACC platform and ProductivityNOW eLearning Site to project VA COR within 14 days of contract award. Only staff that shall utilize the platform to be granted access. Examples: Project manager, sub-contractors POC, Site manager, Safety officer, etc.\nThe access request shall be in writing and include a list of staff. The list shall include the following information:\nFull Name\nCompany Name\nEmail Address\nRole/Position on the project (i.e., Project manager, site super)\nContractor staff granted access to the ACC platform shall complete ACC training through ProductivityNOW eLearning platform and provide certificates of completion to COR within 12 Calendar days of access being granted. Initial access to ProductivityNOW eLearning platform shall expire after 12 Calendar days after online access is granted. \nD)    Additional Staff and Subcontractors can be added at any time with a request submission to the project COR.\nThe contractor shall only use the ACC platform for contract required submissions, official project correspondence to be acknowledged, reviewed, and actioned by the responsible party. No additional time shall be added to the contract, nor an increase in contract amount provided for the contractor s failure to utilize the ACC platform as the project s official communication and collaboration system. Any correspondence out of platform shall not be the governing authority contradicting direction and will be at the contractor s expense. Official project correspondence and collaboration include but not limited to: RFIs, submittals, schedules, shutdown requests, actionable tasks, reports, testing, safety inspections, photos, and site surveys.\nContractor shall inform the COR of any staff changes within 2 business days from the change. Staff changes pertain to staff granted access to the ACC platform. Contractor shall request termination of access, replacement of personnel and/or any other action that might impact the contractor s ability to maintain required utilization of the platform.\nContractor submission requirements cannot be accepted for work to begin without meeting all ACC Platform requirements outlined herein, including completing required ACC platform training.","text":"Stratton VA Medical Center\nAlbany, New York\nStatement of Work (SOW)\nFURNISH & INSTALL ENTRANCE/\nSECURITY DOORS at 10C & 9D\n\nGeneral Scope of Work: Stratton Veterans Administration Medical Center, located at 113 Holland Avenue, Albany NY 12208 is requesting a contract to provide all labor and materials to furnish, install and rework Security/Entrance doors at the following location:\n10C: Existing storefront door with side light system, must have door with opposite swing. New door inset to be provided. New window film to be included.\n9D: Relocate storefront door system from 10D and add missing door to system.\nWork Required:\n9D\nRelocate existing storefront sidelight system from 10C to 9D and add door to system.\n\nContractor will provide all materials, labor and travel to relocate existing storefront door system from 10C to 9D.\nContractor will provide all materials, labor and travel to return the 10D walls and flooring to original by matching existing finishes upon removal of storefront system.\n10C\nContractor will provide all materials, labor and travel to provide NEW storefront door (from Right Hand Reverse(RHR) to Left Hand Reverse (LHR).\nContractor will provide all materials, labor and travel to install NEW hardware and door to LHR swing door.\nExisting door hardware includes:\nFour heavy duty ball bearing butt hinges.\nPush side Von Duprin 99 rim exit device with quiet latch retraction (QEL).\nPush side request to exit with jamb mounted strike.\nPush side Nabco GT 710 low energy operator bronze finish.\nPull side bronze finish thought bolted wire pull handle with cylinder hole.\n\nContractor will provide all materials, labor and travel required to adapt existing access control system to a LHR swing door system.\nContractor will provide all materials, labor and travel required to install new window film as indicated in attached photos.\nVendor will be required to confirm all measurements on-site.\n\nProvided by VA:\n115VAC power above ceiling for operator & exit device power supply\nAll required relocations of sprinkler heads\nVA Police Physical Security will provide port and address information for programming the system into the existing Lenel platform\n\nThe following is required for this contract:\nAll work will be in accordance with:\nNFPA 72: National Fire Alarm and Signaling Code.\nNFPA 70E: Standard for Electrical Safety in the Workplace.\nNFPA 70: National Electrical Code Articles 517, 645 & 800.\nNFPA 77: Recommended Practice on Static Electricity.\nNFPA 99: Healthcare Facilities.\nNFPA 101: Life Safety Code.\nPeriod of Performance\nOne (1) Week after contract award- Submittals due.\nOne (1) Week-Required submittal review.\nOne (1) Week after all materials arrive- Work starts\nOne (1) Week-To complete work.\nTOTAL Four (4) Weeks plus material lead time.\n\nAttachments:\nDoor sample and placement.\nDoor locations.\nAluminum Door Spec.\nGlazing Spec.\n\nLocation of Door on 9D Relocated from 10C\n\n10C WINDOW FILM SAMPLE\n\nSECTION 08 44 13\nGLAZED ALUMINUM CURTAIN WALLS\n\nGENERAL\nDESCRIPTION:\nThis section specifies glazed aluminum curtain wall system.\nThermally isolated, pressure equalized on interior.\nType: Unit and Mullion system to include following:\nUninsulated Metal Panels.\nClosures, trim, subsills and flashings.\nColumn covers.\nFasteners, anchors, and related reinforcement.\nRELATED WORK:\nGlazing: Section 08 80 00, GLAZING.\nQUALITY ASSURANCE:\nQualifications:\nApproval by Contracting Officer Representative (COR) is required of products or services of proposed manufacturer, suppliers and installers, and will be based upon submission by Contractor of certification that:\nManufacturers Qualifications: Manufacturer with five (5) years continuous documented experience in fabrication, of glazed aluminum curtain wall systems of similar types and for projects of equivalent size.\nInstaller: Manufacturer approved in writing who has continuously installed glazed aluminum curtain walls systems of similar types and for projects of equivalent size for previous five (5) years.\n\nDELIVERY, STORAGE AND HANDLING:\nRefer to AAMA CW 10 for care and handling of architectural aluminum from shop to site.\nPrior to packaging for shipment from factory, mark wall components to correspond with shop and erection drawings and their placement location and erection sequence.\nPrior to shipment from factory, place knocked down lineal curtain wall members in cardboard containers and cover finished surfaces of members with protective covering of adhesive paper, waterproof tape, or strippable plastic. Do not cover metal surfaces that will be in contact with sealants after installation.\nPROJECT CONDITIONS:\nField Measurements: Where glazed aluminum curtain wall systems are indicated to fit to other construction, verify dimensions of other construction by field measurements before fabrication and indicate measurements on shop drawings. Coordinate fabrication schedule with construction progress to avoid delaying Work.\nAPPLICABLE PUBLICATIONS:\nPublications listed below form a part of this specification to extent referenced. Publications are referred to in text by basic designation only.\nAmerican Architectural Manufacturers Association (AAMA):\nMCWM-1-89 Metal Curtain Wall Manual\nCW 10-12 Care and Handling of Architectural Aluminum from Shop to Site\nCW 13-85 Structural Sealant Glazing Systems (A Design Guide)\n503-08 Field Testing of Metal Storefronts, Curtain walls and Sloped Glazing Systems\nAmerican Society of Civil Engineers (ASCE):\nASCE 7-10 Minimum Design Loads for Buildings and Other Structures\nASTM International (ASTM):\nA36/A36M-12 Structural Steel\nA123/A123M-13 Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products\nA193/A193M-14a Alloy Steel and Stainless-Steel Bolting Materials for High Temperature Service\nA307-14 Carbon Steel Bolts and Studs, 60,000 PSI Tensile Strength\nB209-14 Aluminum and Aluminum Alloy Sheet and Plate\nB211-12 Aluminum and Aluminum Alloy Bar, Rod, Wire\nB221-14 Aluminum and Aluminum Alloy Extruded Bars, Rods, Wire, Shapes and Tubes\nB316/B316M-10 Aluminum and Aluminum Alloy Rivet and Cold-Heading, Wire, and Rods\nC578-14a Rigid Cellular Polystyrene Thermal Insulation\nC920-14a Elastomeric Joint Sealants\nC794-10 Standard Test Method for Adhesion-In-Peel of Elastomeric Joint Sealants.\nC1193-13 Guide for Use of Joint Sealants\nC1363-11 Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus\nC1521-13 Practice for Evaluating Adhesion of Installed Weatherproofing\nE84-14 Surface Burning Characteristics of Building Materials\nE413-10 Classification for Rating Sound Insulation\nAmerican Welding Society, Inc. (AWS):\nD1.2/D.1.2M-06(R2014) Structural Welding Code Aluminum\nNational Association of Architectural Metal Manufacturers (NAAMM):\n500 Series (2006) Metal Finishes Manual\nSociety for Protective Coatings (SSPC)\nPaint 25-97 (2004) Zinc Oxide, Alkyd, Linseed Oil Primer for Use Over Hand Cleaned Steel Type 1 and Type II\nPaint 20-82 (2019) Zinc-Rich Coating, Type I-Inorganic, and Type II-Organic.\nU.S. Veterans Administration:\nPhysical Security Design Manual for VA Facilities (VAPSDG); Life Safety Protected\nArchitectural Design Manual for VA Facilities (VASDM)\nEnvironmental Protection Agency (EPA):\n40 CFR 59(2014) National Volatile Organic Compound Emission Standards for Consumer and Commercial Products\nWARRANTY:\nConstruction Warranty: Comply with FAR clause 52.246-21, Warranty of Construction .\n\nPRODUCTS\nSYSTEM DESCRIPTION:\nDesign Requirements:\nShop unitized assembly.Â\nMaximum wall framing member deflection, in a direction normal to plane of wall: 1/175 of its clear span or 20 mm (3/4 inch), whichever is less, when designed in accordance with requirements of AAMA TIR A11 and tested in accordance with ASTMÂ E330/E330M.\nMaximum wall framing member deflection when a gypsum wallboard surface is affected: 1/360 of span.\nMaximum Framing Member Permanent Deformation: 0.2 percent of its clear span when tested in accordance with ASTM E330/E330M for a minimum test period of 10 seconds at 1.5 times design wind pressures indicated as part of structural drawing wind load requirements.\nNo glass breakage, or damage to fasteners, hardware or accessories is permitted due to deformation design requirements indicated.\nProvide system complete with framing, mullions, trim, fasteners, anchors, accessories, concealed auxiliary members, and attachment devices for securing wall to structure as specified or indicated. Unless noted otherwise, comply with AAMA MCWM 1.\nObtain all components from single manufacturer.\nFully coordinate system accessories directly incorporated and adjacent to contiguous related work and ensure materials compatibility, deflection limitations, thermal movements, and clearances and tolerances as indicated or specified. Coordinate continuity with adjacent thermal, weather, air and vapor barriers.\nProvide system with adequate allowances for expansion and contraction of components and fastenings to prevent buckling damage, joint seal failure, glass breakage, undue stress on fastening or other detrimental effects. For design purposes, base provisions for thermal movement on assumed ambient temperature range of from 18 degrees C to 49 degrees C (0 degrees F to 120 degrees F).\nProvide wall system to accommodate tolerances in building frame and other contiguous work as indicated or specified.\n\nMATERIALS:\nExtruded Aluminum Framing Members: ASTM B221M (B221); 6063-T5 extruded aluminum for non-structural components or 6063-T6 extruded aluminum for structural members; temper and alloy as recommended by manufacturer.\nSheet Aluminum: ASTM B209M (B209); 6065-T5 temper and alloy as recommended by manufacturer.\nFormed flashing and closures: Minimum 1.58 mm (0.062 inch) thick aluminum, in finish as selected.\nExtruded sill members: Minimum 1.58 mm (0.062 inch) thick aluminum, in finish as selected.\nFasteners:\nFor Framework Connections: ASTM B211M (B211) 2024 T4 aluminum, ASTMÂ A193/A193M B8 300 series, stainless steel, and ASTM B316 aluminum rivets, as required by connection.\nFor Anchoring Glazed Aluminum Curtain Wall to Support Structure: ASTM A307 zinc plated steel fasteners.\nShims: Metal or plastic.\nGlazing Materials:\nAs specified under Section 08 80 00, GLAZING.\nGlazing Gaskets: Interior: Continuous, closed cell PVC foam sealant tape, sealed at corners.\nGlass Sizes and Clearances:\nAccommodate up to 1/4-inch glazing.\nSizes indicated are nominal. Verify actual sizes required by measuring frames. Coordinate dimensions for glass and glass holding members to meet applicable minimum clearances as recommended by glass manufacturers. Do not nip glass to remove flares or to reduce oversized dimensions. All cutting is to occur in factory.\nGlass Setting Materials:\nProvide head bead and drive wedge required for glass installation to suit curtain wall system in accordance with manufacture s recommendations.\nFABRICATION:\nCurtain wall components are to be of materials and thickness indicated in construction documents. Details indicated are representative of required design and profiles. Maintain sightlines. Unless specifically indicated or specified otherwise, methods of fabrication and assembly are to be at discretion of curtain wall manufacturers. Perform fitting and assembling of components in shop to maximum extent practicable. Anchorage devices are to permit adjustment in three directions. No exposed fasteners are permitted.\nJoints: Joints exceeding +1.5 mm (+1/16\") are to be mechanically fastened.\nProtection and Treatment of Metals:\nRemove from metal surfaces lubricants used in fabrication and clean off other extraneous material before leaving shop.\nProvide protection against galvanic action wherever dissimilar metals are in contact, except in case of aluminum in permanent contact with galvanized steel, zinc, stainless steel, or relatively small areas of white bronze. Paint contact surfaces with one coat bituminous paint conforming to MIL C 18480 or apply appropriate caulking material or nonabsorptive, noncorrosive, and non-staining tape or gasket between contact surfaces.\nMetal sills and Closures: Fabricate accessories, spandrel panels, trim closures of sizes and shapes indicated from similar materials and finish as specified for wall system.\nMETAL FINISHES:\nIn accordance with NAAMM AMP500 series.\nAnodized Aluminum:\nAA C22A44 Chemically etched medium matte with electrolytically deposited metallic compound, integrally colored coating Class 1 Architectural, 0.7 mil thick finish. Dyes will not be accepted.\nDark bronze.\n\nEXECUTION\nPREPARATION:\nTake field dimensions and examine condition of substrates, supports, and other conditions under which work of this section is to be performed to verify that work may properly commence. Do not proceed with installation until unsatisfactory conditions have been corrected.\nContact between aluminum and dissimilar metals are to receive a protective coating of bituminous paint for prevention of electrolytic action and corrosion.\nINSTALLATION:\nInstall and erect glazed curtain wall system and all components in accordance with written directions of curtain wall manufacturer. Match profiles, sizes, and spacing indicated on approved shop drawings.\nInstall glazed aluminum curtain wall system so as to maintain a virtually flat face cap, with no visible bowing.\nInstall entire system so that fasteners are not visible.\nTolerances:\nMaximum variation from plane or location shown on approved shop drawings: 3 mm per 3657 mm (1/8 inch per 12 feet) of length up to not more than 13 mm (1/2 inch) in any total length.\nMaximum offset from true alignment between two (2) identical members abutting end to end in line: 0.8 mm (1/32 inch).\nSealant Space Between Curtain Wall Mullion and Adjacent Construction: Maximum of 19 mm (3/4 inch) and minimum of 6 mm (1/4Â inch).\nADJUSTING:\nAdjust doors to provide a tight fit at contact points and operate easily.\nAdjust weather-stripping to make even contact with surfaces.\nAdjust operating hardware and moving parts.\nCLEANING:\nInstall curtain wall frame and associated metal to avoid soiling or smudging finish.\nClean metal surfaces promptly after installation, exercising care to avoid damage to coatings.\nRemove excess glazing and sealant compounds, dirt, and other substances.\nFollow recommendations of manufacturer in selection of cleaning agents. Do not use cleaning agents containing ammonia or other compounds that might damage finished metal surfaces.\nReplace cracked, broken, and defective glass with new glass at no additional cost to Government. Just prior to final acceptance of curtain wall system clean glass surfaces on both sides, remove labels, paint spots, compounds, and other defacements, and clean metal fixed panels. Remove and replace components that cannot be cleaned successfully.\nDEMONSTRATION, TESTING, AND ACCEPTANCE:\nInstruct Government s personnel in proper operation and maintenance of door equipment. Train personnel in procedures to follow in event of operational failures or malfunctions.\nAcceptance: At completion of project, and as a condition of acceptance, door and systems are to be operated for a period of fifteen (15) consecutive calendar days without breakdown.\nPROTECTION:\nAfter installation, protect windows, and other exposed surfaces from disfiguration, contamination, contact with harmful materials, and from other construction hazards that will interfere with their operation, or damage their appearance or finish. Protection methods are to be in accordance with recommendations of product manufacturers or of respective trade association. Remove paper or tape factory applied protection immediately after installation. Clean surfaces of mortar, plaster, paint, smears of sealants, and other foreign matter to present neat appearance and prevent fouling of operation. In addition, wash with a stiff fiber brush, soap and water, and thoroughly rinse. Where surfaces become stained or discolored, clean or restore finish in accordance with recommendations of product manufacturer or respective trade association.\nEND -\n\nSECTION 08 80 00\nGLAZING\nGENERAL\nDESCRIPTION\nThis section specifies the following:\nGlass.\nGlazing materials and accessories for both factory and field glazed assemblies.\nRELATED WORK\nSection 08 44 13, GLAZED ALUMINUM CURTAIN WALLS Glazed Curtain Walls: Glazed Curtain Walls.\nLABELS\nPermanent labels:\nLocate in corner for each pane.\nLabel in accordance with ANSI Z97.1 and SGCC label requirements.\nTempered glass.\nPERFORMANCE REQUIREMENTS\nGeneral: Design glazing system consistent with guidance and practices presented in the GANA Glazing Manual, GANA Laminated Glazing Manual, and GANA Sealant Manual, as applicable to project. Installed glazing is to withstand applied loads, thermal stresses, thermal movements, building movements, permitted tolerances, and combinations of these conditions without failure, including loss or glass breakage attributable to defective manufacture, fabrication, or installation; failure of sealants or gaskets to remain watertight and airtight; deterioration of glazing materials; unsafe engagement of the framing system; deflections beyond specified limits; or other defects in construction.\nGlazing Unit Design: Design glass, including engineering analysis meeting requirements of authorities having jurisdiction. Thicknesses listed are minimum. Coordinate thicknesses with framing system manufacturers.\nDesign glass in accordance with ASTM E1300, and for conditions beyond the scope of ASTM E1300, by a properly substantiated structural analysis.\nMaximum Lateral Deflection: For glass supported on all four edges, limit center-of-glass deflection at design wind pressure to not more than the structural capacity of the glazing unit, the threshold at which frame engagement is no longer safely assured, 1/100 times the short-side length, or 19 mm (0.75 inch), whichever is less.\nDELIVERY, STORAGE AND HANDLING\nDelivery: Schedule delivery to coincide with glazing schedules so minimum handling of crates is required. Do not open crates except as required for inspection for shipping damage.\nStorage: Store cases according to printed instructions on case, in areas least subject to traffic or falling objects. Keep storage area clean and dry.\nHandling: Unpack cases following printed instructions on case. Stack individual windows on edge leaned slightly against upright supports with separators between each.\nProtect laminated security glazing units against face and edge damage during entire sequence of fabrication, handling, and delivery to installation location. Provide protective covering on exposed faces of glazing plastics, and mark inside as \"INTERIOR FACE\" or \"PROTECTED FACE\":\nTreat security glazing as fragile merchandise and packaged and shipped in export wood cases with width end in upright position and blocked together in a mass. Storage and handling to comply with manufacturer's directions and as required to prevent edge damage or other damage to glazing resulting from effects of moisture, condensation, temperature changes, direct exposure to sun, other environmental conditions, and contact with chemical solvents.\nProtect sealed-air-space insulating glazing units from exposure to abnormal pressure changes, as could result from substantial changes in altitude during delivery by air freight. Provide temporary breather tubes which do not nullify applicable warranties on hermetic seals.\nTemporary protections: The glass front and polycarbonate back of glazing are to be temporarily protected with compatible, peelable, heat-resistant film which will be peeled for inspections and re applied and finally removed after doors and windows are installed at destination. Since many adhesives will attack polycarbonate, the film used on exposed polycarbonate surfaces is to be approved and applied by manufacturer.\nEdge protection: To cushion and protect glass clad, and polycarbonate edges from contamination or foreign matter, the fourÂ (4) edges are to be sealed the depth of glazing with continuous standard thickness thermoplastic rubber tape. Alternatively, continuous channel shaped extrusion of thermoplastic rubber are to be used, with flanges extending into face sides of glazing.\nPROJECT CONDITIONS:\nField Measurements: Field measure openings before ordering tempered glass products to assure for proper fit of field measured products.\nAPPLICABLE PUBLICATIONS:\nPublications listed below form a part of this specification to extent referenced. Publications are referenced in text by basic designation only.\nAmerican Architectural Manufacturers Association (AAMA):\n800 Test Methods for Sealants\n810.1-77 Expanded Cellular Glazing Tape\nAmerican National Standards Institute (ANSI):\nZ97.1-14 Safety Glazing Material Used in Building Safety Performance Specifications and Methods of Test\nASTM International (ASTM):\nC542-05(2017) Lock-Strip Gaskets\nC716-06(2020) Installing Lock-Strip Gaskets and Infill Glazing Materials\nC794-18 Adhesion-in-Peel of Elastomeric Joint Sealants\nC864-05(2019) Dense Elastomeric Compression Seal Gaskets, Setting Blocks, and Spacers\nC920-18 Elastomeric Joint Sealants\nC964-20 Standard Guide for Lock-Strip Gasket Glazing\nD635-18 Rate of Burning and/or Extent and Time of Burning of Self-Supporting Plastic in a Horizontal Position\nE84-20 Surface Burning Characteristics of Building Materials\nE119-20 Standard Test Methods for Fire Test of Building Construction and Material\nE1300-16 Load Resistance of Glass in Buildings\nF1233-08(2019) Standard Test Method for Security Glazing Materials and Systems\nF1642/F1642M-17 Test Method for Glazing and Glazing Systems Subject to Airblast Loadings\nCode of Federal Regulations (CFR):\n16 CFR 1201-10 Safety Standard for Architectural Glazing Materials\nGlass Association of North America (GANA):\n2010 Edition GANA Glazing Manual\n2008 Edition GANA Sealant Manual\n2010 Edition GANA Protective Glazing Reference Manual\nInternational Code Council (ICC):\nIBC International Building Code\nIntertek Testing Services Warnock Hersey (ITS-WHI)\nNational Fire Protection Association (NFPA):\n80-16 Fire Doors and Windows\n252-12 Fire Tests of Door Assemblies\nNational Fenestration Rating Council (NFRC)\nSafety Glazing Certification Council (SGCC) 2012:\nCertified Products Directory (Issued Semi-Annually).\nUnderwriters Laboratories, Inc. (UL):\n9-08(R2009) Fire Tests of Window Assemblies\n263-14 Fire Tests of Building Construction and Materials\nDepartment of Veterans Affairs:\nArchitectural Design Manual for VA Facilities (VASDM)\n\nPRODUCT\n\nGLASS\nProvide minimum thickness stated and as additionally required to meet performance requirements.\nProvide minimum 6 mm (1/4 inch) thick glass units unless otherwise indicated.\nObtain glass units from single source from single manufacturer for each glass type.\nClear Glass:\nASTM C1036, Type I, Class 1.\n\nGLAZING ACCESSORIES\nAs required to supplement the accessories provided with the items to be glazed and to provide a complete installation. Ferrous metal accessories exposed in the finished work are to have a finish that will not corrode or stain while in service. Fire rated glazing to be installed with glazing accessories in accordance with the manufacturer s installation instructions.\nSpacers: ASTM C864:\nChannel shape having a 6 mm (1/4 inch) internal depth.\nFlanges not less 2.4 mm (3/32 inch) thick and web 3 mm (1/8 inch) thick.\nLengths: 25 to 76 mm (1 to 3 inches).\nShore A hardness of 40 to 50 Durometer.\nGlazing Tapes:\nSemi solid polymeric based closed cell material exhibiting pressure sensitive adhesion and withstanding exposure to sunlight, moisture, heat, cold, and aging.\nShape, size and degree of softness and strength suitable for use in glazing application to prevent water infiltration.\nComplying with AAMA 800 for the following types:\nAAMA 810.1, Type 1, for glazing applications in which tape acts as the primary sealant.\nAAMA 810.1, Type 2, for glazing applications in which tape is used in combination with a full bead of liquid sealant.\nSpring Steel Spacer: Galvanized steel wire or strip designed to position glazing in channel or rabbeted sash with stops.\nGlazing Clips: Galvanized steel spring wire designed to hold glass in position in rabbeted sash without stops.\nGlazing Points (Sprigs): Pure zinc stock, thin, flat, triangular or diamond shaped pieces, 6 mm (1/4 inch) minimum size.\nGlazing Gaskets: ASTM C864:\nFirm dense wedge shape for locking in sash.\nSoft, closed cell with locking key for sash key.\nFlanges may terminate above the glazing beads or terminate flush with top of beads.\n\nEXECUTION\nEXAMINATION\nVerification of Conditions:\nExamine openings for glass and glazing units; determine they are proper size; plumb; square; and level before installation is started.\nVerify that glazing openings conform with details, dimensions and tolerances indicated on manufacturer is approved shop drawings.\nReview for conditions which may adversely affect glass and glazing unit installation, prior to commencement of installation. Do not proceed with installation until unsatisfactory conditions have been corrected.\nVerify that wash down of adjacent masonry is completed prior to erection of glass and glazing units.\nPREPARATION\nFor sealant glazing, prepare glazing surfaces in accordance with GANAÂ Sealant Manual.\nDetermine glazing unit size and edge clearances by measuring the actual unit to receive the glazing.\nShop fabricate and cut glass with smooth, straight edges of full size required by openings to provide GANA recommended edge clearances.\nVerify that components used are compatible.\nClean and dry glazing surfaces.\nPrime surfaces scheduled to receive sealants, as determined by preconstruction sealant-substrate testing.\nINSTALLATION GENERAL\nInstall in accordance with GANA Glazing Manual, GANA Sealant Manual, IGMA TB-3001, and IGMA TM-3000 unless specified otherwise.\nGlaze in accordance with recommendations of glazing and framing manufacturers, and as required to meet the Performance Test Requirements specified in other applicable sections of specifications.\nSet glazing without bending, twisting, or forcing of units.\nDo not allow glass to rest on or contact any framing member.\nGlaze doors and operable sash, in a securely fixed or closed and locked position, until sealant, glazing compound, or putty has thoroughly set.\nTempered Glass: Install with roller distortions in horizontal position unless otherwise directed.\nINSTALLATION INTERIOR WET/DRY METHOD (TAPE AND SEALANT)\nCut glazing tape to length and install against permanent stops, projecting 1.6 mm (1/16 inch) above sight line.\nPlace setting blocks at 1/4 points with edge block no more than 150 mm (6 inches) from corners.\nRest glazing on setting blocks and push against tape to ensure full contact at perimeter of pane or unit.\nInstall removable stops, spacer shims inserted between glazing and applied stops at 600 mm (24 inch) intervals, 6 mm (1/4 inch) below sight line.\nFill gaps between pane and applied stop with sealant to depth equal to bite on glazing, to uniform and level line. Sealant type is to be compatible with glazing tape.\nTrim protruding tape edge.\nREPLACEMENT AND CLEANING\nClean new glass surfaces removing temporary labels, paint spots, and defacement after approval by COR.\nReplace cracked, broken, and imperfect glass, or glass which has been installed improperly.\nLeave glass, putty, and other setting material in clean, whole, and acceptable condition.\nPROTECTION\nProtect finished surfaces from damage during erection, and after completion of work. Strippable plastic coatings on colored anodized finish are not acceptable.\n\nAutodesk Build Construction Management Platform\n\nAutodesk build construction management platform:\nThe Contractor shall utilize VISN 2 Autodesk Build Construction management platform, also called Autodesk Construction Cloud (ACC).\nAccess to the platform and training portal will be provided by VISN 2 through project Contracting Officer Representative (COR) at no cost for the duration of the project. Autodesk Build is the management and collaborative environment that VISN 2 uses for all its Non-Recurring Maintenance (NRM), Minor Program projects, Feasibility Studies, Commissioning and Retro-Commissioning contracts. There is no user, license, or subscription fee to the contractor for using this cloud-based platform.\nThe Contractor shall accomplish and complete the following tasks upon award of contract:\nRequest access to ACC platform and ProductivityNOW eLearning Site to project VA COR within 14 days of contract award. Only staff that shall utilize the platform to be granted access. Examples: Project manager, sub-contractors POC, Site manager, Safety officer, etc.\nThe access request shall be in writing and include a list of staff. The list shall include the following information:\nFull Name\nCompany Name\nEmail Address\nRole/Position on the project (i.e., Project manager, site super)\nContractor staff granted access to the ACC platform shall complete ACC training through ProductivityNOW eLearning platform and provide certificates of completion to COR within 12 Calendar days of access being granted. Initial access to ProductivityNOW eLearning platform shall expire after 12 Calendar days after online access is granted.\nD) Additional Staff and Subcontractors can be added at any time with a request submission to the project COR.\nThe contractor shall only use the ACC platform for contract required submissions, official project correspondence to be acknowledged, reviewed, and actioned by the responsible party. No additional time shall be added to the contract, nor an increase in contract amount provided for the contractor s failure to utilize the ACC platform as the project s official communication and collaboration system. Any correspondence out of platform shall not be the governing authority contradicting direction and will be at the contractor s expense. Official project correspondence and collaboration include but not limited to: RFIs, submittals, schedules, shutdown requests, actionable tasks, reports, testing, safety inspections, photos, and site surveys.\nContractor shall inform the COR of any staff changes within 2 business days from the change. Staff changes pertain to staff granted access to the ACC platform. Contractor shall request termination of access, replacement of personnel and/or any other action that might impact the contractor s ability to maintain required utilization of the platform.\nContractor submission requirements cannot be accepted for work to begin without meeting all ACC Platform requirements outlined herein, including completing required ACC platform training.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24226Q0220","product_service_code":"Z1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-12-23","posted_at":"2025-12-23T19:18:32.614Z","created_at":"2025-12-23T19:18:30.184Z","modified_at":"2026-02-02T04:55:43.495Z","response_deadline":{"raw":"2026-01-02T13:00:00-05:00","utc":"2026-01-02T18:00:00Z","date":"2026-01-02","time":"13:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/447aaffdecde4e1a95cd6612c486861f/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-02-01","archive_type":"auto_custom"},"history":[{"index":4,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-23T19:18:32.614Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"447aaffdecde4e1a95cd6612c486861f","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":2,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-22T19:42:53.477Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"199f4aeebba84def98a20c343586d71a","solicitation_number":"36C24226Q0220","parent_opportunity_id":"adff049e6c374adbb8888540ea704ec3"},{"index":1,"title":"Z1DA--ALBANY 8C,9D & 10C Door install/retrofit 2.0","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T21:02:24.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"adff049e6c374adbb8888540ea704ec3","solicitation_number":"36C24226Q0220","related_opportunity_id":"eade96c3df684f0b8f63d8e475258adc"}],"contacts":[{"name":"Terry Fraser","role":"primary","email":"terry.fraser@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"447aaffdecde4e1a95cd6612c486861f","lineage_id":"adff049e6c374adbb8888540ea704ec3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-18T02:03:31.036655904Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"2d3ba1f50217c0616e7c768e1b62fe1570d5a5bb94ce24c14414b7a584c24c77","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-18T02:03:31.036655904Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"INSTRUCTIONS, CONDITIONS AND OTHER STATEMENTS TO BIDDERS/OFFERORS\nGENERAL INTENTION\nREQUESTS FOR INFORMATION (RFI):\nTo obtain clarifications and/or additional information concerning the contract requirements or specifications, submit a written RFI via email to terry.fraser@va.gov. \nRFIs will be responded to as necessary in amendment format which will be posted on http://www.beta.sam.gov\nThe deadline for submission of RFIs for this solicitation is Monday, December 29, 2025, at 3:00 PM (EST).  No questions will be answered after this date/time unless determined to be in the best interest of the Government as determined by the Contracting Officer.  Telephone RFIs will not be accepted or returned.\nBASIS FOR AWARD\nContract award will be made to the responsive, responsible bidder submitting the lowest price in accordance with FAR Part 14   Sealed Bidding.\nRESPONSIBILITY REQUIREMENTS \nA Determination of Responsibility shall be accomplished for the apparent awardee prior to processing the award.Â  The above information, along with other information obtained from Government systems, such as the OSHA and EPA online inspection history databases will be used to make the Determination of Responsibility.Â Â  Failure to affirm being within the guidelines above or submit this information may result in a determination of  Non-Responsibility  for the bidder/offeror.Â  NOTE: Any information received by the Government that would cause for a negative Determination of Responsibility may make the bidder/offeror ineligible for award.\nThis requirement is applicable to all subcontracting tiers, and prospective prime contractors are responsible for determining the responsibility of their prospective subcontractors.\n\n\n\n\n\nDELIVERY OF BIDS\n\nThere will not be a face-to-face public bid opening. In accordance with FAR 14.202-8, send all submission documents via email toÂ terry.fraser@va.govÂ by 1:00 PM EST Friday, January 2, 2026.  Bids received after this time may be rejected.\nAll Contractors providing an electronic bid submission must still meet all requirements listed under  Bid Submission  in the solicitation. The bid opening and public reading of the bids will be via teleconference.  Bidders may call +1 347-566-4838,,  at 1:15 PM EST and enter participant code 279 385 442# to join. \nThe bid submission emails will be kept in an electronic folder unread until 1:15 PM EST when they will be opened and read to the public.  \nFiles should be in Adobe* PDF (Portable Document Format) Files:Â  Size:Â  Maximum size of the e-mail message shall not exceed five (5) megabytes. If the size limits are exceeded, the VA may not receive the file and/or you may not be considered.   Only one email is permitted.  This email should contain at least the following as separate attachments: \nOne (1) signed SF1442 with amendments acknowledged. \nInclude response to FAR 52.204-8(2) (i) or (ii) Annual Representations and Certifications\nResponse to FAR 52.209-13(b)(1) or (2) Violation of Arms Controls Treaties or Agreements\nOne (1) complete signed SF 24 Bid Bond and Power of Attorney.\nOne (1) safety or environmental violations and experience modification rate.\nOne (1) Class Deviation to Implement SDVOSB and VOSB Certification Requirements","text":"INSTRUCTIONS, CONDITIONS AND OTHER STATEMENTS TO BIDDERS/OFFERORS\nGENERAL INTENTION\nREQUESTS FOR INFORMATION (RFI):\nTo obtain clarifications and/or additional information concerning the contract requirements or specifications, submit a written RFI via email to terry.fraser@va.gov.\nRFIs will be responded to as necessary in amendment format which will be posted on http://www.beta.sam.gov\nThe deadline for submission of RFIs for this solicitation is Monday, December 29, 2025, at 3:00 PM (EST). No questions will be answered after this date/time unless determined to be in the best interest of the Government as determined by the Contracting Officer. Telephone RFIs will not be accepted or returned.\nBASIS FOR AWARD\nContract award will be made to the responsive, responsible bidder submitting the lowest price in accordance with FAR Part 14 Sealed Bidding.\nRESPONSIBILITY REQUIREMENTS\nA Determination of Responsibility shall be accomplished for the apparent awardee prior to processing the award.Â The above information, along with other information obtained from Government systems, such as the OSHA and EPA online inspection history databases will be used to make the Determination of Responsibility.Â Â Failure to affirm being within the guidelines above or submit this information may result in a determination of Non-Responsibility for the bidder/offeror.Â NOTE: Any information received by the Government that would cause for a negative Determination of Responsibility may make the bidder/offeror ineligible for award.\nThis requirement is applicable to all subcontracting tiers, and prospective prime contractors are responsible for determining the responsibility of their prospective subcontractors.\n\nDELIVERY OF BIDS\n\nThere will not be a face-to-face public bid opening. In accordance with FAR 14.202-8, send all submission documents via email toÂ terry.fraser@va.govÂ by 1:00 PM EST Friday, January 2, 2026. Bids received after this time may be rejected.\nAll Contractors providing an electronic bid submission must still meet all requirements listed under Bid Submission in the solicitation. The bid opening and public reading of the bids will be via teleconference. Bidders may call +1 347-566-4838,, at 1:15 PM EST and enter participant code 279 385 442# to join.\nThe bid submission emails will be kept in an electronic folder unread until 1:15 PM EST when they will be opened and read to the public.\nFiles should be in Adobe* PDF (Portable Document Format) Files:Â Size:Â Maximum size of the e-mail message shall not exceed five (5) megabytes. If the size limits are exceeded, the VA may not receive the file and/or you may not be considered. Only one email is permitted. This email should contain at least the following as separate attachments:\nOne (1) signed SF1442 with amendments acknowledged.\nInclude response to FAR 52.204-8(2) (i) or (ii) Annual Representations and Certifications\nResponse to FAR 52.209-13(b)(1) or (2) Violation of Arms Controls Treaties or Agreements\nOne (1) complete signed SF 24 Bid Bond and Power of Attorney.\nOne (1) safety or environmental violations and experience modification rate.\nOne (1) Class Deviation to Implement SDVOSB and VOSB Certification Requirements","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24226Q0220","product_service_code":"Z1DA"}],"due_at":"2026-01-02T18:00:00Z","due_date":"2026-01-02","closes_at":"2026-01-02T18:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36001","county_name":"Albany County","city":"3601000","city_name":"Albany","country":null,"state_source":null,"state_evidence":null,"site_key":null,"winner_key":"MUDPMKWH76B8","amount":null,"linked_awards":4,"cancelled":false,"archived":true,"updated_at":"2026-10-18T02:20:31.626818Z","principal_notice_id":"447aaffdecde4e1a95cd6612c486861f","description":{"text":"INSTRUCTIONS, CONDITIONS AND OTHER STATEMENTS TO BIDDERS/OFFERORS\nGENERAL INTENTION\nREQUESTS FOR INFORMATION (RFI):\nTo obtain clarifications and/or additional information concerning the contract requirements or specifications, submit a written RFI via email to terry.fraser@va.gov.\nRFIs will be responded to as necessary in amendment format which will be posted on http://www.beta.sam.gov\nThe deadline for submission of RFIs for this solicitation is Monday, December 29, 2025, at 3:00 PM (EST). No questions will be answered after this date/time unless determined to be in the best interest of the Government as determined by the Contracting Officer. Telephone RFIs will not be accepted or returned.\nBASIS FOR AWARD\nContract award will be made to the responsive, responsible bidder submitting the lowest price in accordance with FAR Part 14 Sealed Bidding.\nRESPONSIBILITY REQUIREMENTS\nA Determination of Responsibility shall be accomplished for the apparent awardee prior to processing the award.Â The above information, along with other information obtained from Government systems, such as the OSHA and EPA online inspection history databases will be used to make the Determination of Responsibility.Â Â Failure to affirm being within the guidelines above or submit this information may result in a determination of Non-Responsibility for the bidder/offeror.Â NOTE: Any information received by the Government that would cause for a negative Determination of Responsibility may make the bidder/offeror ineligible for award.\nThis requirement is applicable to all subcontracting tiers, and prospective prime contractors are responsible for determining the responsibility of their prospective subcontractors.\n\nDELIVERY OF BIDS\n\nThere will not be a face-to-face public bid opening. In accordance with FAR 14.202-8, send all submission documents via email toÂ terry.fraser@va.govÂ by 1:00 PM EST Friday, January 2, 2026. Bids received after this time may be rejected.\nAll Contractors providing an electronic bid submission must still meet all requirements listed under Bid Submission in the solicitation. The bid opening and public reading of the bids will be via teleconference. Bidders may call +1 347-566-4838,, at 1:15 PM EST and enter participant code 279 385 442# to join.\nThe bid submission emails will be kept in an electronic folder unread until 1:15 PM EST when they will be opened and read to the public.\nFiles should be in Adobe* PDF (Portable Document Format) Files:Â Size:Â Maximum size of the e-mail message shall not exceed five (5) megabytes. If the size limits are exceeded, the VA may not receive the file and/or you may not be considered. Only one email is permitted. This email should contain at least the following as separate attachments:\nOne (1) signed SF1442 with amendments acknowledged.\nInclude response to FAR 52.204-8(2) (i) or (ii) Annual Representations and Certifications\nResponse to FAR 52.209-13(b)(1) or (2) Violation of Arms Controls Treaties or Agreements\nOne (1) complete signed SF 24 Bid Bond and Power of Attorney.\nOne (1) safety or environmental violations and experience modification rate.\nOne (1) Class Deviation to Implement SDVOSB and VOSB Certification Requirements","html":"INSTRUCTIONS, CONDITIONS AND OTHER STATEMENTS TO BIDDERS/OFFERORS\nGENERAL INTENTION\nREQUESTS FOR INFORMATION (RFI):\nTo obtain clarifications and/or additional information concerning the contract requirements or specifications, submit a written RFI via email to terry.fraser@va.gov. \nRFIs will be responded to as necessary in amendment format which will be posted on http://www.beta.sam.gov\nThe deadline for submission of RFIs for this solicitation is Monday, December 29, 2025, at 3:00 PM (EST).  No questions will be answered after this date/time unless determined to be in the best interest of the Government as determined by the Contracting Officer.  Telephone RFIs will not be accepted or returned.\nBASIS FOR AWARD\nContract award will be made to the responsive, responsible bidder submitting the lowest price in accordance with FAR Part 14   Sealed Bidding.\nRESPONSIBILITY REQUIREMENTS \nA Determination of Responsibility shall be accomplished for the apparent awardee prior to processing the award.Â  The above information, along with other information obtained from Government systems, such as the OSHA and EPA online inspection history databases will be used to make the Determination of Responsibility.Â Â  Failure to affirm being within the guidelines above or submit this information may result in a determination of  Non-Responsibility  for the bidder/offeror.Â  NOTE: Any information received by the Government that would cause for a negative Determination of Responsibility may make the bidder/offeror ineligible for award.\nThis requirement is applicable to all subcontracting tiers, and prospective prime contractors are responsible for determining the responsibility of their prospective subcontractors.\n\n\n\n\n\nDELIVERY OF BIDS\n\nThere will not be a face-to-face public bid opening. In accordance with FAR 14.202-8, send all submission documents via email toÂ terry.fraser@va.govÂ by 1:00 PM EST Friday, January 2, 2026.  Bids received after this time may be rejected.\nAll Contractors providing an electronic bid submission must still meet all requirements listed under  Bid Submission  in the solicitation. The bid opening and public reading of the bids will be via teleconference.  Bidders may call +1 347-566-4838,,  at 1:15 PM EST and enter participant code 279 385 442# to join. \nThe bid submission emails will be kept in an electronic folder unread until 1:15 PM EST when they will be opened and read to the public.  \nFiles should be in Adobe* PDF (Portable Document Format) Files:Â  Size:Â  Maximum size of the e-mail message shall not exceed five (5) megabytes. If the size limits are exceeded, the VA may not receive the file and/or you may not be considered.   Only one email is permitted.  This email should contain at least the following as separate attachments: \nOne (1) signed SF1442 with amendments acknowledged. \nInclude response to FAR 52.204-8(2) (i) or (ii) Annual Representations and Certifications\nResponse to FAR 52.209-13(b)(1) or (2) Violation of Arms Controls Treaties or Agreements\nOne (1) complete signed SF 24 Bid Bond and Power of Attorney.\nOne (1) safety or environmental violations and experience modification rate.\nOne (1) Class Deviation to Implement SDVOSB and VOSB Certification Requirements","origin":"detail"},"contacts":[{"name":"Terry Fraser","role":"primary","email":"terry.fraser@va.gov","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["236220"],"award":{"awardee":{}},"attachments":[{"resource_id":"22b1bf1bd5b64fa798b9640173bf2f82","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-12-16T21:01:21.797Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false},{"resource_id":"66757858f92f4bd9977e350e65efb59c","name":"36C24226Q0220.docx","kind":"file","mime_type":".docx","size_bytes":78044,"posted_at":"2025-12-16T21:02:24.056Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/66757858f92f4bd9977e350e65efb59c/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24226P0349_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24226P0349_3600_-NONE-_-NONE-/","piid":"36C24226P0349","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"MUDPMKWH76B8","recipient_name":"IRON SWORD ENTERPRISES, LLC","recipient_uei":"MUDPMKWH76B8","recipient_cage":"5VSS8","recipient_city":"WALLKILL","recipient_state":"NY","sub_name":"Department of Veterans Affairs","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","office_key":"o-36C242","first_action_date":"2026-03-16","last_action_date":"2026-03-16","actions":1,"obligated":"58800.00","current_total_value":"58800.00","potential_total_value":"58800.00","naics":"236220","psc":"Z1DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":2,"description":"INSTALL 9D & 10C DOORS FOR ALBANY VA MEDICAL CENTER","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24226Q0220 equals the FPDS solicitation identifier","same awarding office 36C242"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227B00050001","latest_notice_id":"684f30abb8934f0393559f87438724b3","title":"Z1DA--528A5-27-504 Seal and Stripe Parking Lots","solicitation_number":"36C24227B0005-0001","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"NY","county":"36069","county_name":"Ontario County","city":"3612144","city_name":"Canandaigua","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227B0005","latest_notice_id":"d91ec8aa1ebf44dfab4a2168f6e4a162","title":"Z1DA--528A5-27-504 Seal and Stripe Parking Lots","solicitation_number":"36C24227B0005","notice_type":"o","first_type":"p","first_posted":"2026-10-13","last_posted":"2026-10-29","notices":3,"due_at":"2026-12-03T16:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Z1DA","set_aside":"SDVOSBC","state":"NY","county":"36069","county_name":"Ontario County","city":"3612144","city_name":"Canandaigua","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"}],"similar_open_total":192,"indexable":false}