{"canonical":"https://sealedbidder.com/opportunities/36c24226q0208","key":"36C24226Q0208","url":"https://sealedbidder.com/opportunities/36c24226q0208","title":"J041--Chiller Plant/ ARF Services Contract","solicitation_number":"36C24226Q0208","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-12-22T15:00:00Z","first_posted":"2025-12-16","last_posted":"2025-12-16","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238220","psc":"J041","set_aside":null,"place_state":"NY","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"36001","place_county_name":"Albany County","place_city":"3601000","place_city_name":"Albany","winner":null,"award_amount":null,"publications":[{"notice_id":"4aa00783ef0a451d933562644309418c","title":"J041--Chiller Plant/ ARF Services Contract","solicitation_number":"36C24226Q0208","notice_type":"r","base_type":"r","posted":"2025-12-16","posted_at":"2025-12-16T12:59:35.427Z","due_at":"2025-12-22T15:00:00Z","due_date":"2025-12-22","cancelled":false,"archived":true,"archive_date":"2026-03-31","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4aa00783ef0a451d933562644309418c/view","enriched":true,"history":[{"index":3,"title":"J041--Chiller Plant/ ARF Services Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T12:59:35.427Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"4aa00783ef0a451d933562644309418c","solicitation_number":"36C24226Q0208"}]}],"latest_notice_id":"4aa00783ef0a451d933562644309418c","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-12-16","posted_at":"2025-12-16T12:59:35.427Z","created_at":"2025-12-16T12:59:33.225Z","modified_at":"2026-04-01T04:00:08.055Z","response_deadline":{"raw":"2025-12-22T10:00:00-05:00","utc":"2025-12-22T15:00:00Z","date":"2025-12-22","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4aa00783ef0a451d933562644309418c/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"J041--Chiller Plant/ ARF Services Contract","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-31","archive_type":"auto_custom"},"history":[{"index":3,"title":"J041--Chiller Plant/ ARF Services Contract","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-16T12:59:35.427Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"4aa00783ef0a451d933562644309418c","solicitation_number":"36C24226Q0208"}],"contacts":[{"name":"Natalie Acevedo","role":"primary","email":"natalie.acevedo@va.gov","phone":"718 584 9000 x4356","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"4aa00783ef0a451d933562644309418c","lineage_id":"4aa00783ef0a451d933562644309418c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-19T00:44:31.255160594Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"9a49c6e6bff35cfdf728ed2a1d4dbf53011a1eb0c973b4133a400ca3cc2e6fa4","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-19T00:44:31.255160594Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"This is a SOURCES SOUGHT NOTICE for market research purposes only to determine the\navailability of potential businesses with capabilities to provide the service described in the\nStatement of Work (SOW) / Performance Work Statement (PWS). Potential offerors are invited to provide information via e-mail to\nnatalie.acevedo@va.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition according to Performance Work Statement (PWS).\nPotential contractors shall provide, at a minimum, the following information to\nnatalie.acevedo@va.gov:\n1) Name, address, point of contact name, phone number, and e-mail address.\n2) Brief capability statement with enough information to determine if the company can meet the requirement. The Capabilities Statement for this sources sought is not expected to be a Request for Quote (RFQ) nor does it restrict the Government to an ultimate acquisition approach but rather provide a short statement regarding the company's ability to provide the services as detailed in the Statement of Work. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement.\n3) Statement attesting, they are properly certified in accordance with the SOW/PWS.\nThe capabilities will be evaluated solely for the purpose of determining the appropriate\nacquisition strategy for this requirement. The Government must ensure there is an adequate competition among the potential pool of available contractors using SBA website. \nThis synopsis is for information and planning purposes only and is not to be construed as a\ncommitment by the Government nor will the Government pay for information solicited. This\nsynopsis is not a solicitation announcement for Request for Quote (RFQ). No formal solicitation\ndocument exists at this time, and no contract will be awarded from this announcement.\n\nRespondents will not be notified of the results of the evaluation. Interested contractors should respond via email by 10:00 AM (EST) on December 22, 2025.\n\n\n\nPERFORMANCE WORK STATEMENT SUMMARY:\nGeneral: The Stratton VA Medical Center in Albany New York is seeking services for Central Chiller Plant and OR Chillers operation, maintenance and repair services.  The intent is to cover preventive maintenance and repairs on all Main chiller plant equipment and OR chillers in the inventory listed below, as stipulated in this performance work statement.\nDescription of Services/Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Chiller Maintenance and repairs Service as defined in this Performance Work Statement except for those items specified as government furnished property and services.  The contractor shall meet the standards in this contract.\nEquipment:\n Main chiller Building # 54 Maintenance, Operation, Inspection, Repair.\n1) 1 Trane Centrifugal Chiller 750-ton 1000# R-123\n2) 2 Trane Centrifugal Chiller 750-ton 1000# R-123\n3) 3 Trane Centrifugal Chiller 1000-ton 1700# R-123\n4) Main Chiller Building Roof Cooling tower #1 BAC Model 3604A-2\n5) Main Chiller Building Roof Cooling tower #2 BAC Model 3604A-2\n6) Main Chiller Building Roof Cooling tower #3 BAC Model 3456C-2\n7) Variable Frequency Drives \n8) Equipment from Attachment A, B,C, D chiller plant inventory  \nMain Hospital Sub basement OR Chiller Maintenance, Operation, Inspection, Repair.\nOR Chiller 1 \n                    Manufacturer: Trane\n                    Model: RTUD110F\n                   Serial: U22J03995\n\nOR Chiller 2 \n                   Manufacturer: Trane\n                   Model: RTUD110F\n                  Serial: U22J03994\nVariable Frequency Drives\nEquipment from Attachment B OR /ARF plant inventory\n\nObjectives:  This contract will produce a tangible, implementable solution that assures safe efficient operation and maintenance of the Main Hospital chiller plant and OR Chillers Listed in the inventory at the Stratton VA Medical Center.\nScope: Services to be provided are:\nPreventive Maintenance schedule sees attachment C\nCovered items main chiller plant Valves, actuators, pumps, motors, vfd, see attachment A\nCovered items OR chiller plant Valves, actuators, pumps, motors, vfd, see attachment B\nCovered items ARF Chiller stated in attachment A\nAll services currently covered under the existing contract 47QSWA20D002A/ MOD  47QAWA20D002A\nChiller Operation / Automation\nRepairs Normal PM s and 24-hour emergency response to alarms and equipment failures called in by FMS personnel \nOperation integrity\nEddy Current testing on a 3-year basis option year 2 2029 See attachment D\nYear-Round cooling season  \n(2) Tower cleanings per year for Towers 1-2\nOne Tower Cleaning per year for Tower 3 \nAnnual cleaning of plate and frame heat exchanger \n\nDISCLAIMER\nThis Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","text":"This is a SOURCES SOUGHT NOTICE for market research purposes only to determine the\navailability of potential businesses with capabilities to provide the service described in the\nStatement of Work (SOW) / Performance Work Statement (PWS). Potential offerors are invited to provide information via e-mail to\nnatalie.acevedo@va.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition according to Performance Work Statement (PWS).\nPotential contractors shall provide, at a minimum, the following information to\nnatalie.acevedo@va.gov:\n1) Name, address, point of contact name, phone number, and e-mail address.\n2) Brief capability statement with enough information to determine if the company can meet the requirement. The Capabilities Statement for this sources sought is not expected to be a Request for Quote (RFQ) nor does it restrict the Government to an ultimate acquisition approach but rather provide a short statement regarding the company's ability to provide the services as detailed in the Statement of Work. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement.\n3) Statement attesting, they are properly certified in accordance with the SOW/PWS.\nThe capabilities will be evaluated solely for the purpose of determining the appropriate\nacquisition strategy for this requirement. The Government must ensure there is an adequate competition among the potential pool of available contractors using SBA website.\nThis synopsis is for information and planning purposes only and is not to be construed as a\ncommitment by the Government nor will the Government pay for information solicited. This\nsynopsis is not a solicitation announcement for Request for Quote (RFQ). No formal solicitation\ndocument exists at this time, and no contract will be awarded from this announcement.\n\nRespondents will not be notified of the results of the evaluation. Interested contractors should respond via email by 10:00 AM (EST) on December 22, 2025.\n\nPERFORMANCE WORK STATEMENT SUMMARY:\nGeneral: The Stratton VA Medical Center in Albany New York is seeking services for Central Chiller Plant and OR Chillers operation, maintenance and repair services. The intent is to cover preventive maintenance and repairs on all Main chiller plant equipment and OR chillers in the inventory listed below, as stipulated in this performance work statement.\nDescription of Services/Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Chiller Maintenance and repairs Service as defined in this Performance Work Statement except for those items specified as government furnished property and services. The contractor shall meet the standards in this contract.\nEquipment:\nMain chiller Building # 54 Maintenance, Operation, Inspection, Repair.\n1) 1 Trane Centrifugal Chiller 750-ton 1000# R-123\n2) 2 Trane Centrifugal Chiller 750-ton 1000# R-123\n3) 3 Trane Centrifugal Chiller 1000-ton 1700# R-123\n4) Main Chiller Building Roof Cooling tower #1 BAC Model 3604A-2\n5) Main Chiller Building Roof Cooling tower #2 BAC Model 3604A-2\n6) Main Chiller Building Roof Cooling tower #3 BAC Model 3456C-2\n7) Variable Frequency Drives\n8) Equipment from Attachment A, B,C, D chiller plant inventory\nMain Hospital Sub basement OR Chiller Maintenance, Operation, Inspection, Repair.\nOR Chiller 1\nManufacturer: Trane\nModel: RTUD110F\nSerial: U22J03995\n\nOR Chiller 2\nManufacturer: Trane\nModel: RTUD110F\nSerial: U22J03994\nVariable Frequency Drives\nEquipment from Attachment B OR /ARF plant inventory\n\nObjectives: This contract will produce a tangible, implementable solution that assures safe efficient operation and maintenance of the Main Hospital chiller plant and OR Chillers Listed in the inventory at the Stratton VA Medical Center.\nScope: Services to be provided are:\nPreventive Maintenance schedule sees attachment C\nCovered items main chiller plant Valves, actuators, pumps, motors, vfd, see attachment A\nCovered items OR chiller plant Valves, actuators, pumps, motors, vfd, see attachment B\nCovered items ARF Chiller stated in attachment A\nAll services currently covered under the existing contract 47QSWA20D002A/ MOD 47QAWA20D002A\nChiller Operation / Automation\nRepairs Normal PM s and 24-hour emergency response to alarms and equipment failures called in by FMS personnel\nOperation integrity\nEddy Current testing on a 3-year basis option year 2 2029 See attachment D\nYear-Round cooling season\n(2) Tower cleanings per year for Towers 1-2\nOne Tower Cleaning per year for Tower 3\nAnnual cleaning of plate and frame heat exchanger\n\nDISCLAIMER\nThis Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24226Q0208","place_of_performance":{"zip":"12208","city":{"code":"1000","name":"Albany"},"state":{"code":"NY","name":"New York"},"street":"Stratton VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"113 Holland Avenue"},"product_service_code":"J041"}],"due_at":"2025-12-22T15:00:00Z","due_date":"2025-12-22","closes_at":"2025-12-22T15:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36001","county_name":"Albany County","city":"3601000","city_name":"Albany","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-19T01:14:25.828228Z","principal_notice_id":"4aa00783ef0a451d933562644309418c","description":{"text":"This is a SOURCES SOUGHT NOTICE for market research purposes only to determine the\navailability of potential businesses with capabilities to provide the service described in the\nStatement of Work (SOW) / Performance Work Statement (PWS). Potential offerors are invited to provide information via e-mail to\nnatalie.acevedo@va.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition according to Performance Work Statement (PWS).\nPotential contractors shall provide, at a minimum, the following information to\nnatalie.acevedo@va.gov:\n1) Name, address, point of contact name, phone number, and e-mail address.\n2) Brief capability statement with enough information to determine if the company can meet the requirement. The Capabilities Statement for this sources sought is not expected to be a Request for Quote (RFQ) nor does it restrict the Government to an ultimate acquisition approach but rather provide a short statement regarding the company's ability to provide the services as detailed in the Statement of Work. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement.\n3) Statement attesting, they are properly certified in accordance with the SOW/PWS.\nThe capabilities will be evaluated solely for the purpose of determining the appropriate\nacquisition strategy for this requirement. The Government must ensure there is an adequate competition among the potential pool of available contractors using SBA website.\nThis synopsis is for information and planning purposes only and is not to be construed as a\ncommitment by the Government nor will the Government pay for information solicited. This\nsynopsis is not a solicitation announcement for Request for Quote (RFQ). No formal solicitation\ndocument exists at this time, and no contract will be awarded from this announcement.\n\nRespondents will not be notified of the results of the evaluation. Interested contractors should respond via email by 10:00 AM (EST) on December 22, 2025.\n\nPERFORMANCE WORK STATEMENT SUMMARY:\nGeneral: The Stratton VA Medical Center in Albany New York is seeking services for Central Chiller Plant and OR Chillers operation, maintenance and repair services. The intent is to cover preventive maintenance and repairs on all Main chiller plant equipment and OR chillers in the inventory listed below, as stipulated in this performance work statement.\nDescription of Services/Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Chiller Maintenance and repairs Service as defined in this Performance Work Statement except for those items specified as government furnished property and services. The contractor shall meet the standards in this contract.\nEquipment:\nMain chiller Building # 54 Maintenance, Operation, Inspection, Repair.\n1) 1 Trane Centrifugal Chiller 750-ton 1000# R-123\n2) 2 Trane Centrifugal Chiller 750-ton 1000# R-123\n3) 3 Trane Centrifugal Chiller 1000-ton 1700# R-123\n4) Main Chiller Building Roof Cooling tower #1 BAC Model 3604A-2\n5) Main Chiller Building Roof Cooling tower #2 BAC Model 3604A-2\n6) Main Chiller Building Roof Cooling tower #3 BAC Model 3456C-2\n7) Variable Frequency Drives\n8) Equipment from Attachment A, B,C, D chiller plant inventory\nMain Hospital Sub basement OR Chiller Maintenance, Operation, Inspection, Repair.\nOR Chiller 1\nManufacturer: Trane\nModel: RTUD110F\nSerial: U22J03995\n\nOR Chiller 2\nManufacturer: Trane\nModel: RTUD110F\nSerial: U22J03994\nVariable Frequency Drives\nEquipment from Attachment B OR /ARF plant inventory\n\nObjectives: This contract will produce a tangible, implementable solution that assures safe efficient operation and maintenance of the Main Hospital chiller plant and OR Chillers Listed in the inventory at the Stratton VA Medical Center.\nScope: Services to be provided are:\nPreventive Maintenance schedule sees attachment C\nCovered items main chiller plant Valves, actuators, pumps, motors, vfd, see attachment A\nCovered items OR chiller plant Valves, actuators, pumps, motors, vfd, see attachment B\nCovered items ARF Chiller stated in attachment A\nAll services currently covered under the existing contract 47QSWA20D002A/ MOD 47QAWA20D002A\nChiller Operation / Automation\nRepairs Normal PM s and 24-hour emergency response to alarms and equipment failures called in by FMS personnel\nOperation integrity\nEddy Current testing on a 3-year basis option year 2 2029 See attachment D\nYear-Round cooling season\n(2) Tower cleanings per year for Towers 1-2\nOne Tower Cleaning per year for Tower 3\nAnnual cleaning of plate and frame heat exchanger\n\nDISCLAIMER\nThis Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","html":"This is a SOURCES SOUGHT NOTICE for market research purposes only to determine the\navailability of potential businesses with capabilities to provide the service described in the\nStatement of Work (SOW) / Performance Work Statement (PWS). Potential offerors are invited to provide information via e-mail to\nnatalie.acevedo@va.gov. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition according to Performance Work Statement (PWS).\nPotential contractors shall provide, at a minimum, the following information to\nnatalie.acevedo@va.gov:\n1) Name, address, point of contact name, phone number, and e-mail address.\n2) Brief capability statement with enough information to determine if the company can meet the requirement. The Capabilities Statement for this sources sought is not expected to be a Request for Quote (RFQ) nor does it restrict the Government to an ultimate acquisition approach but rather provide a short statement regarding the company's ability to provide the services as detailed in the Statement of Work. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement.\n3) Statement attesting, they are properly certified in accordance with the SOW/PWS.\nThe capabilities will be evaluated solely for the purpose of determining the appropriate\nacquisition strategy for this requirement. The Government must ensure there is an adequate competition among the potential pool of available contractors using SBA website. \nThis synopsis is for information and planning purposes only and is not to be construed as a\ncommitment by the Government nor will the Government pay for information solicited. This\nsynopsis is not a solicitation announcement for Request for Quote (RFQ). No formal solicitation\ndocument exists at this time, and no contract will be awarded from this announcement.\n\nRespondents will not be notified of the results of the evaluation. Interested contractors should respond via email by 10:00 AM (EST) on December 22, 2025.\n\n\n\nPERFORMANCE WORK STATEMENT SUMMARY:\nGeneral: The Stratton VA Medical Center in Albany New York is seeking services for Central Chiller Plant and OR Chillers operation, maintenance and repair services.  The intent is to cover preventive maintenance and repairs on all Main chiller plant equipment and OR chillers in the inventory listed below, as stipulated in this performance work statement.\nDescription of Services/Introduction: The contractor shall provide all personnel, equipment, supplies, facilities, transportation, tools, materials, supervision, and other items and non-personal services necessary to perform Chiller Maintenance and repairs Service as defined in this Performance Work Statement except for those items specified as government furnished property and services.  The contractor shall meet the standards in this contract.\nEquipment:\n Main chiller Building # 54 Maintenance, Operation, Inspection, Repair.\n1) 1 Trane Centrifugal Chiller 750-ton 1000# R-123\n2) 2 Trane Centrifugal Chiller 750-ton 1000# R-123\n3) 3 Trane Centrifugal Chiller 1000-ton 1700# R-123\n4) Main Chiller Building Roof Cooling tower #1 BAC Model 3604A-2\n5) Main Chiller Building Roof Cooling tower #2 BAC Model 3604A-2\n6) Main Chiller Building Roof Cooling tower #3 BAC Model 3456C-2\n7) Variable Frequency Drives \n8) Equipment from Attachment A, B,C, D chiller plant inventory  \nMain Hospital Sub basement OR Chiller Maintenance, Operation, Inspection, Repair.\nOR Chiller 1 \n                    Manufacturer: Trane\n                    Model: RTUD110F\n                   Serial: U22J03995\n\nOR Chiller 2 \n                   Manufacturer: Trane\n                   Model: RTUD110F\n                  Serial: U22J03994\nVariable Frequency Drives\nEquipment from Attachment B OR /ARF plant inventory\n\nObjectives:  This contract will produce a tangible, implementable solution that assures safe efficient operation and maintenance of the Main Hospital chiller plant and OR Chillers Listed in the inventory at the Stratton VA Medical Center.\nScope: Services to be provided are:\nPreventive Maintenance schedule sees attachment C\nCovered items main chiller plant Valves, actuators, pumps, motors, vfd, see attachment A\nCovered items OR chiller plant Valves, actuators, pumps, motors, vfd, see attachment B\nCovered items ARF Chiller stated in attachment A\nAll services currently covered under the existing contract 47QSWA20D002A/ MOD  47QAWA20D002A\nChiller Operation / Automation\nRepairs Normal PM s and 24-hour emergency response to alarms and equipment failures called in by FMS personnel \nOperation integrity\nEddy Current testing on a 3-year basis option year 2 2029 See attachment D\nYear-Round cooling season  \n(2) Tower cleanings per year for Towers 1-2\nOne Tower Cleaning per year for Tower 3 \nAnnual cleaning of plate and frame heat exchanger \n\nDISCLAIMER\nThis Sources Sought is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.","origin":"detail"},"contacts":[{"name":"Natalie Acevedo","role":"primary","email":"natalie.acevedo@va.gov","phone":"718 584 9000 x4356","title":"Contracting Officer"}],"place_of_performance":{"zip":"12208","city":{"code":"1000","name":"Albany"},"state":{"code":"NY","name":"New York"},"street":"Stratton VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"113 Holland Avenue"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["238220"],"award":{"awardee":{}},"attachments":[{"resource_id":"40fc2e5f7075457488472b37dd34b493","name":"36C24226Q0208.docx","kind":"file","mime_type":".docx","size_bytes":18414,"posted_at":"2025-12-16T12:59:35.427Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/40fc2e5f7075457488472b37dd34b493/download","mirrored":false}],"awards":[],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"36C24227R0008","latest_notice_id":"a4209158195e4eaaa69a73f455b90ed4","title":"Z1DA--NRM CONST - 528A7-18-707 - Replace Boiler Stack Rome CBOC","solicitation_number":"36C24227R0008","notice_type":"o","first_type":"p","first_posted":"2026-10-14","last_posted":"2026-11-20","notices":6,"due_at":"2026-12-02T15:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238220","psc":"Z1DA","set_aside":"SBA","state":"NY","county":"36065","county_name":"Oneida County","city":"3663418","city_name":"Rome","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"70ZL14Q0000006","latest_notice_id":"f1d0674e9de64955b0c327a1e89bd8f6","title":"REMOVE AND REPLACE 13 PROPANE REGULATORS, USCG STA FIRE ISLAND HOUSING, BABYLON, NY 11702-4602","solicitation_number":"70ZL14Q0000006","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":2,"due_at":"2026-12-07T22:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL14","office_name":"BASE BOSTON","naics":"238220","psc":"Z1FA","set_aside":"SBA","state":"NY","county":"36103","county_name":"Suffolk County","city":"3603408","city_name":"Babylon","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":57,"indexable":false}