{"canonical":"https://sealedbidder.com/opportunities/36c24226b0016","key":"36C24226B0016","url":"https://sealedbidder.com/opportunities/36c24226b0016","title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","solicitation_number":"36C24226B0016","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-12-22T17:30:00Z","first_posted":"2025-11-07","last_posted":"2025-12-12","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238210","psc":"Y1DA","set_aside":"SDVOSBC","place_state":"NY","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"36101","place_county_name":"Steuben County","place_city":"3604759","place_city_name":"Bath","winner":"NORTHERN DREAMS CONSTRUCTION, INC","award_amount":null,"publications":[{"notice_id":"eb6cd159a6304eceacb827516a578627","title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","solicitation_number":"36C24226B0016","notice_type":"p","base_type":"p","posted":"2025-11-07","posted_at":"2025-11-07T19:05:41.373Z","due_at":"2025-12-17T17:30:00Z","due_date":"2025-12-17","cancelled":false,"archived":true,"archive_date":"2026-02-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/eb6cd159a6304eceacb827516a578627/view","enriched":true,"history":[{"index":4,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T19:05:41.373Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"eb6cd159a6304eceacb827516a578627","solicitation_number":"36C24226B0016"},{"index":2,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-21T19:39:53.019Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3","solicitation_number":"36C24226B0016","related_opportunity_id":"eb6cd159a6304eceacb827516a578627"}]},{"notice_id":"45d4426e6c6443b8810fbe72756bf2f3","title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","solicitation_number":"36C24226B0016","notice_type":"o","base_type":"p","posted":"2025-11-21","posted_at":"2025-11-21T19:39:53.019Z","due_at":"2025-12-22T17:30:00Z","due_date":"2025-12-22","cancelled":false,"archived":true,"archive_date":"2026-02-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/45d4426e6c6443b8810fbe72756bf2f3/view","enriched":true,"history":[{"index":6,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T19:05:41.373Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"eb6cd159a6304eceacb827516a578627","solicitation_number":"36C24226B0016"},{"index":4,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-12T19:23:30.775Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9558e836d169490cb6413171aeadc3c0","solicitation_number":"36C24226B0016","parent_opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3"},{"index":2,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-21T19:39:53.019Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3","solicitation_number":"36C24226B0016","related_opportunity_id":"eb6cd159a6304eceacb827516a578627"}]},{"notice_id":"9558e836d169490cb6413171aeadc3c0","title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","solicitation_number":"36C24226B0016","notice_type":"o","base_type":"o","posted":"2025-12-12","posted_at":"2025-12-12T19:23:30.775Z","due_at":"2025-12-22T17:30:00Z","due_date":"2025-12-22","cancelled":false,"archived":true,"archive_date":"2026-01-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9558e836d169490cb6413171aeadc3c0/view","enriched":true,"history":[{"index":3,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-12T19:23:30.775Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9558e836d169490cb6413171aeadc3c0","solicitation_number":"36C24226B0016","parent_opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3"},{"index":1,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-21T19:39:53.019Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3","solicitation_number":"36C24226B0016","related_opportunity_id":"eb6cd159a6304eceacb827516a578627"}]}],"latest_notice_id":"9558e836d169490cb6413171aeadc3c0","first_type":"p","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-11-07","posted_at":"2025-11-07T19:05:41.373Z","created_at":"2025-11-07T19:05:40.180Z","modified_at":"2026-02-16T04:55:44.270Z","response_deadline":{"raw":"2025-12-17T12:30:00-05:00","utc":"2025-12-17T17:30:00Z","date":"2025-12-17","time":"12:30:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/eb6cd159a6304eceacb827516a578627/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-02-15","archive_type":"auto_custom"},"history":[{"index":4,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T19:05:41.373Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"eb6cd159a6304eceacb827516a578627","solicitation_number":"36C24226B0016"},{"index":2,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-21T19:39:53.019Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3","solicitation_number":"36C24226B0016","related_opportunity_id":"eb6cd159a6304eceacb827516a578627"}],"contacts":[{"name":"Devan Bertch","role":"primary","email":"Devan.Bertch@va.gov","phone":"716-698-6459","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"eb6cd159a6304eceacb827516a578627","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"45d4426e6c6443b8810fbe72756bf2f3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-23T02:55:19.879922205Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"6ab03f4ced7905126bbb17c82f56803cd2497959870fe86b816a29024d18076a","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-23T02:55:19.879922205Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"This pre-solicitation notice is to inform that the VA Medical Center, Bath, New York will be posting a solicitation on or about November 13th, 2025 for Connect PIVs to Fire Alarm System at the Bath VA Medical Center. Project No. 528A6-24-612\n  \nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78.\n\n The total project duration for this project is not to exceed 180 days from the date of the NTP issuance.  This includes all processes starting with submission and approval of all submittals and ending with final punch list completion.\n\nThe NAICS code is 238210 - Electrical Contractors and Other Wiring Installation Contractors. The small business standard is $19.0 M. The cost range is between $250,000 and $500,000. Information regarding the one and only site visit scheduled will be stated in the Solicitation. A 20% Bid Bond must be submitted with the bid. Performance and Payment bonds will be required.","text":"This pre-solicitation notice is to inform that the VA Medical Center, Bath, New York will be posting a solicitation on or about November 13th, 2025 for Connect PIVs to Fire Alarm System at the Bath VA Medical Center. Project No. 528A6-24-612\n\nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78.\n\nThe total project duration for this project is not to exceed 180 days from the date of the NTP issuance. This includes all processes starting with submission and approval of all submittals and ending with final punch list completion.\n\nThe NAICS code is 238210 - Electrical Contractors and Other Wiring Installation Contractors. The small business standard is $19.0 M. The cost range is between $250,000 and $500,000. Information regarding the one and only site visit scheduled will be stated in the Solicitation. A 20% Bid Bond must be submitted with the bid. Performance and Payment bonds will be required.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24226B0016","place_of_performance":{"zip":"14810","city":{"code":"4759","name":"Bath"},"state":{"code":"NY","name":"New York"},"country":{"code":"USA","name":"UNITED STATES"},"street2":"Bath VA Medical Center 76 Veterans Ave"},"product_service_code":"Y1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-11-21","posted_at":"2025-11-21T19:39:53.019Z","created_at":"2025-11-21T19:38:58.953Z","modified_at":"2026-01-22T04:55:57.927Z","response_deadline":{"raw":"2025-12-22T12:30:00-05:00","utc":"2025-12-22T17:30:00Z","date":"2025-12-22","time":"12:30:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/45d4426e6c6443b8810fbe72756bf2f3/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-02-20","archive_type":"auto_custom"},"history":[{"index":6,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-07T19:05:41.373Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"eb6cd159a6304eceacb827516a578627","solicitation_number":"36C24226B0016"},{"index":4,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-12T19:23:30.775Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9558e836d169490cb6413171aeadc3c0","solicitation_number":"36C24226B0016","parent_opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3"},{"index":2,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-21T19:39:53.019Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3","solicitation_number":"36C24226B0016","related_opportunity_id":"eb6cd159a6304eceacb827516a578627"}],"contacts":[{"name":"Devan Bertch","role":"primary","email":"Devan.Bertch@va.gov","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"45d4426e6c6443b8810fbe72756bf2f3","lineage_id":"45d4426e6c6443b8810fbe72756bf2f3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-21T03:33:39.405694697Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"1055d944b7f3c73a8feea06419fe4f6798b693b2bd1c7fdbfa67689540f69101","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-21T03:33:39.405694697Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"Project No.  528A6-24-612\nConnect PIV s to Fire Alarm System\nConstruction Services Statement of Work\n\nPage 2 of 3\nBath VA Medical Center    76 Veterans Avenue      Bath, NY 14810\nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78.\nExisting Conditions\nPost indicator valves (PIV s) previously installed with new station water system currently require manual inspection/supervision and system supervision will be added. These 22 valves are building adjacent and will be linked via radio to control relays in each building s fire alarm system. Most of these buildings are aging brick structures on grounds with many legacy underground systems around them. This makes wire/conduit trenches and internal wiring routing challenging. Changing conditions over time necessitate protecting some valves from equipment and vehicle impacts. \n\nBuilding 78, the Community Living Center (CLC) is the onsite nursing home at the VA Medical Center (VAMC) located in Bath, New York. The current fire alarm system, 1 zone for building, does not support the current fire practice of 11 zones, 9 of which are living spaces, one for attic, one for crawlspace. This structure has been more recently remodeled, so has relatively easier structural access however is also a working patient nursing facility so work needs to be well planned and coordinated with nursing staff.\n \nCurrent station fire system uses Johnson Controls/Honeywell Verifire programming and components.\nConstruction will include, but is not limited to:\nPost Indicator Valve (PIV) bollard protection. \nRemoval, including underground portions, of existing bollards to be replaced. \nPreparation of new bollard locations including survey for locations and conflicting underground utilities.\nInstallation of bollard protection.\nReturn of surrounding areas to project specified and/or previous conditions. \nSome of these locations involve asphalt and concrete surfaces. \nSupport of post project documentation. \n\nInstallation and integration of post indicator valves (PIV) to fire control panel systems\nSupply, installation and configuration of Potter radio switch and supporting communication equipment.\nConnection to signaling line circuits (SLC) of Johnson Controls (JCI)/Honeywell fire alarm systems, to include wall penetrations, fire conduit, and panel installation.\nThis will include penetration and sealing of masonry walls.\nConfiguration and programming of existing station wide Johnson Controls  Verifire  based systems for new equipment.\nSupport of post project documentation. \n\nInstallation and integration of zone voice alarms into building 78 the community living center residence. Reconfiguration of single fire zone into 11, with 9 living areas\nSupply, install, wire, and connect new fire control panels.\nSupply, install, wire, and connect new annunciators.\nConfigure and program fire alarm system for new zoning and equipment in all panels and monitoring locations. \nEnsure conditions around new equipment are restored similar to existing.\nSupport of post project documentation. \n\nSafety Measures: \nReview and incorporate risk assessment and interim life safety plans and measures into safety and construction planning.\nPre Construction Risk Analysis (PCRA) by VA\nInterim Life Safety Measures (ILSM) by VA\nGenerate and follow a safety plan and incorporate risk  and life safety assessments. \n\nThe Contractor shall supply:\nAll the materials, tools, labor, and supervision to complete this project as required on the contract drawings and in the specifications. \nJCI/Honeywell  Verifire  software is required\nJCI/Honeywell hardware is required\nPotter Signalink hardware and software is required.\nContractor will adhere strictly to the plans and specifications unless directed otherwise by the CO in writing. \nContractor shall have 180 days from the  Notice to Proceed  to complete all work.\nCommunications and Standards\nAll contract direction, changes, financials, and contract performance are the responsibility of the VAMC Contracting Officer (CO).\nContracting Officers Technical Representative (COR) is responsible for day-to-day operations in project and the primary point of contact (POC) for project.\nCommunications to/from VAMC, \nTechnical communications, submittals, RFI s, change orders\nOn site visits for construction and sub-contractors\nConstruction coordination\nSite work coordination\n\nProject is required to use the Autodesk Construction Cloud Build Platform (ACC)\nBath VAMC will provide licensing, permissions, and online training for this cloud-based tool at no cost to contractors. \nContractor required to actively use Build on ACC for project documentation and coordination. \nACC is used for submittals, requests for information, project communications and documentation. \nNo contract financial information on ACC\nNo personal identification information on ACC.\nProject must, at a minimum, be in accordance with \nAll federal, state, and local building and safety codes MUST be followed. \nAll work is to be completed as shown on the contract documents drawings and specifications unless otherwise directed by the facility/CO in writing.\nIndustry Construction Standards\nNational Fire Protection Association (NFPA), \nUnderwriters Laboratory, \nInternational Building Code IBC 2003, \nNational Electric Code (NEC), \nVA Information Security Handbook 6500.6, etc.\nThe C&A Information Technology requirements do not apply, and a Security Accreditation Package is not required.\n\nVA supplies\nAccess and coordination with Bath VAMC station utilities and site\n\nLicensing, permissions, and online training for Autodesk Construction Cloud Build (ACC).\n\nLocation on station, north of railroad tracks, for staging area, trailers, parking","text":"Project No. 528A6-24-612\nConnect PIV s to Fire Alarm System\nConstruction Services Statement of Work\n\nPage 2 of 3\nBath VA Medical Center 76 Veterans Avenue Bath, NY 14810\nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78.\nExisting Conditions\nPost indicator valves (PIV s) previously installed with new station water system currently require manual inspection/supervision and system supervision will be added. These 22 valves are building adjacent and will be linked via radio to control relays in each building s fire alarm system. Most of these buildings are aging brick structures on grounds with many legacy underground systems around them. This makes wire/conduit trenches and internal wiring routing challenging. Changing conditions over time necessitate protecting some valves from equipment and vehicle impacts.\n\nBuilding 78, the Community Living Center (CLC) is the onsite nursing home at the VA Medical Center (VAMC) located in Bath, New York. The current fire alarm system, 1 zone for building, does not support the current fire practice of 11 zones, 9 of which are living spaces, one for attic, one for crawlspace. This structure has been more recently remodeled, so has relatively easier structural access however is also a working patient nursing facility so work needs to be well planned and coordinated with nursing staff.\n\nCurrent station fire system uses Johnson Controls/Honeywell Verifire programming and components.\nConstruction will include, but is not limited to:\nPost Indicator Valve (PIV) bollard protection.\nRemoval, including underground portions, of existing bollards to be replaced.\nPreparation of new bollard locations including survey for locations and conflicting underground utilities.\nInstallation of bollard protection.\nReturn of surrounding areas to project specified and/or previous conditions.\nSome of these locations involve asphalt and concrete surfaces.\nSupport of post project documentation.\n\nInstallation and integration of post indicator valves (PIV) to fire control panel systems\nSupply, installation and configuration of Potter radio switch and supporting communication equipment.\nConnection to signaling line circuits (SLC) of Johnson Controls (JCI)/Honeywell fire alarm systems, to include wall penetrations, fire conduit, and panel installation.\nThis will include penetration and sealing of masonry walls.\nConfiguration and programming of existing station wide Johnson Controls Verifire based systems for new equipment.\nSupport of post project documentation.\n\nInstallation and integration of zone voice alarms into building 78 the community living center residence. Reconfiguration of single fire zone into 11, with 9 living areas\nSupply, install, wire, and connect new fire control panels.\nSupply, install, wire, and connect new annunciators.\nConfigure and program fire alarm system for new zoning and equipment in all panels and monitoring locations.\nEnsure conditions around new equipment are restored similar to existing.\nSupport of post project documentation.\n\nSafety Measures:\nReview and incorporate risk assessment and interim life safety plans and measures into safety and construction planning.\nPre Construction Risk Analysis (PCRA) by VA\nInterim Life Safety Measures (ILSM) by VA\nGenerate and follow a safety plan and incorporate risk and life safety assessments.\n\nThe Contractor shall supply:\nAll the materials, tools, labor, and supervision to complete this project as required on the contract drawings and in the specifications.\nJCI/Honeywell Verifire software is required\nJCI/Honeywell hardware is required\nPotter Signalink hardware and software is required.\nContractor will adhere strictly to the plans and specifications unless directed otherwise by the CO in writing.\nContractor shall have 180 days from the Notice to Proceed to complete all work.\nCommunications and Standards\nAll contract direction, changes, financials, and contract performance are the responsibility of the VAMC Contracting Officer (CO).\nContracting Officers Technical Representative (COR) is responsible for day-to-day operations in project and the primary point of contact (POC) for project.\nCommunications to/from VAMC,\nTechnical communications, submittals, RFI s, change orders\nOn site visits for construction and sub-contractors\nConstruction coordination\nSite work coordination\n\nProject is required to use the Autodesk Construction Cloud Build Platform (ACC)\nBath VAMC will provide licensing, permissions, and online training for this cloud-based tool at no cost to contractors.\nContractor required to actively use Build on ACC for project documentation and coordination.\nACC is used for submittals, requests for information, project communications and documentation.\nNo contract financial information on ACC\nNo personal identification information on ACC.\nProject must, at a minimum, be in accordance with\nAll federal, state, and local building and safety codes MUST be followed.\nAll work is to be completed as shown on the contract documents drawings and specifications unless otherwise directed by the facility/CO in writing.\nIndustry Construction Standards\nNational Fire Protection Association (NFPA),\nUnderwriters Laboratory,\nInternational Building Code IBC 2003,\nNational Electric Code (NEC),\nVA Information Security Handbook 6500.6, etc.\nThe C&A Information Technology requirements do not apply, and a Security Accreditation Package is not required.\n\nVA supplies\nAccess and coordination with Bath VAMC station utilities and site\n\nLicensing, permissions, and online training for Autodesk Construction Cloud Build (ACC).\n\nLocation on station, north of railroad tracks, for staging area, trailers, parking","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24226B0016","product_service_code":"Y1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-12-12","posted_at":"2025-12-12T19:23:30.775Z","created_at":"2025-12-12T19:22:49.378Z","modified_at":"2026-01-22T04:55:57.927Z","response_deadline":{"raw":"2025-12-22T12:30:00-05:00","utc":"2025-12-22T17:30:00Z","date":"2025-12-22","time":"12:30:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9558e836d169490cb6413171aeadc3c0/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-01-21","archive_type":"auto_custom"},"history":[{"index":3,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-12T19:23:30.775Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9558e836d169490cb6413171aeadc3c0","solicitation_number":"36C24226B0016","parent_opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3"},{"index":1,"title":"Y1DA--528A6-24-612 Connect PIVs to Fire Alarm System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-21T19:39:53.019Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"45d4426e6c6443b8810fbe72756bf2f3","solicitation_number":"36C24226B0016","related_opportunity_id":"eb6cd159a6304eceacb827516a578627"}],"contacts":[{"name":"Devan Bertch","role":"primary","email":"Devan.Bertch@va.gov","title":"Contract Specialist"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"9558e836d169490cb6413171aeadc3c0","lineage_id":"45d4426e6c6443b8810fbe72756bf2f3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-19T02:43:44.455373883Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"856c632d00a3355c75547cd64fcf0dc3eab1203c78e522ecf80e551c70d89eb4","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-19T02:43:44.455373883Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"Project No. 528A6-24-612 Connect PIV s to Fire Alarm System \n\nBath VA Medical Center 76 Veterans Avenue Bath, NY 14810 \nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78. \n\nExisting Conditions \nPost indicator valves (PIV s) previously installed with new station water system currently require manual inspection/supervision and system supervision will be added. These 22 valves are building adjacent and will be linked via radio to control relays in each building s fire alarm system. Most of these buildings are aging brick structures on grounds with many legacy underground systems around them. This makes wire/conduit trenches and internal wiring routing challenging. Changing conditions over time necessitate protecting some valves from equipment and vehicle impacts. \nBuilding 78, the Community Living Center (CLC) is the onsite nursing home at the VA Medical Center (VAMC) located in Bath, New York. The current fire alarm system, 1 zone for building, does not support the current fire practice of 11 zones, 9 of which are living spaces, one for attic, one for crawlspace. This structure has been more recently remodeled, so has relatively easier structural access however is also a working patient nursing facility so work needs to be well planned and coordinated with nursing staff. \n\nCurrent station fire system uses Johnson Controls/Honeywell Verifire programming and compon","text":"Project No. 528A6-24-612 Connect PIV s to Fire Alarm System\n\nBath VA Medical Center 76 Veterans Avenue Bath, NY 14810\nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78.\n\nExisting Conditions\nPost indicator valves (PIV s) previously installed with new station water system currently require manual inspection/supervision and system supervision will be added. These 22 valves are building adjacent and will be linked via radio to control relays in each building s fire alarm system. Most of these buildings are aging brick structures on grounds with many legacy underground systems around them. This makes wire/conduit trenches and internal wiring routing challenging. Changing conditions over time necessitate protecting some valves from equipment and vehicle impacts.\nBuilding 78, the Community Living Center (CLC) is the onsite nursing home at the VA Medical Center (VAMC) located in Bath, New York. The current fire alarm system, 1 zone for building, does not support the current fire practice of 11 zones, 9 of which are living spaces, one for attic, one for crawlspace. This structure has been more recently remodeled, so has relatively easier structural access however is also a working patient nursing facility so work needs to be well planned and coordinated with nursing staff.\n\nCurrent station fire system uses Johnson Controls/Honeywell Verifire programming and compon","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24226B0016","product_service_code":"Y1DA"}],"due_at":"2025-12-22T17:30:00Z","due_date":"2025-12-22","closes_at":"2025-12-22T17:30:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36101","county_name":"Steuben County","city":"3604759","city_name":"Bath","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"NYDFBMPJRFK7","amount":null,"linked_awards":3,"cancelled":false,"archived":true,"updated_at":"2026-10-19T03:18:05.767149Z","principal_notice_id":"9558e836d169490cb6413171aeadc3c0","description":{"text":"Project No. 528A6-24-612 Connect PIV s to Fire Alarm System\n\nBath VA Medical Center 76 Veterans Avenue Bath, NY 14810\nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78.\n\nExisting Conditions\nPost indicator valves (PIV s) previously installed with new station water system currently require manual inspection/supervision and system supervision will be added. These 22 valves are building adjacent and will be linked via radio to control relays in each building s fire alarm system. Most of these buildings are aging brick structures on grounds with many legacy underground systems around them. This makes wire/conduit trenches and internal wiring routing challenging. Changing conditions over time necessitate protecting some valves from equipment and vehicle impacts.\nBuilding 78, the Community Living Center (CLC) is the onsite nursing home at the VA Medical Center (VAMC) located in Bath, New York. The current fire alarm system, 1 zone for building, does not support the current fire practice of 11 zones, 9 of which are living spaces, one for attic, one for crawlspace. This structure has been more recently remodeled, so has relatively easier structural access however is also a working patient nursing facility so work needs to be well planned and coordinated with nursing staff.\n\nCurrent station fire system uses Johnson Controls/Honeywell Verifire programming and compon","html":"Project No. 528A6-24-612 Connect PIV s to Fire Alarm System \n\nBath VA Medical Center 76 Veterans Avenue Bath, NY 14810 \nThe general scope of this project is for installation, testing, and commissioning services to add post indicator valve (PIV) system supervision and protection and update the fire zones and add voice alarms in building 78. \n\nExisting Conditions \nPost indicator valves (PIV s) previously installed with new station water system currently require manual inspection/supervision and system supervision will be added. These 22 valves are building adjacent and will be linked via radio to control relays in each building s fire alarm system. Most of these buildings are aging brick structures on grounds with many legacy underground systems around them. This makes wire/conduit trenches and internal wiring routing challenging. Changing conditions over time necessitate protecting some valves from equipment and vehicle impacts. \nBuilding 78, the Community Living Center (CLC) is the onsite nursing home at the VA Medical Center (VAMC) located in Bath, New York. The current fire alarm system, 1 zone for building, does not support the current fire practice of 11 zones, 9 of which are living spaces, one for attic, one for crawlspace. This structure has been more recently remodeled, so has relatively easier structural access however is also a working patient nursing facility so work needs to be well planned and coordinated with nursing staff. \n\nCurrent station fire system uses Johnson Controls/Honeywell Verifire programming and compon","origin":"detail"},"contacts":[{"name":"Devan Bertch","role":"primary","email":"Devan.Bertch@va.gov","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["238210"],"award":{"awardee":{}},"attachments":[{"resource_id":"fdb26dbe9b194ea3b3391e09c95ec2ef","name":"36C24226B0016_1.docx","kind":"file","mime_type":".docx","size_bytes":15329,"posted_at":"2025-11-07T19:05:41.373Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/fdb26dbe9b194ea3b3391e09c95ec2ef/download","mirrored":false},{"resource_id":"aee8f686a58144a7bf08799f48f2319f","name":"36C24226B0016_2.docx","kind":"file","mime_type":".docx","size_bytes":109161,"posted_at":"2025-11-21T19:39:53.019Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/aee8f686a58144a7bf08799f48f2319f/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24226C0032_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24226C0032_3600_-NONE-_-NONE-/","piid":"36C24226C0032","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"NYDFBMPJRFK7","recipient_name":"NORTHERN DREAMS CONSTRUCTION, INC","recipient_uei":"NYDFBMPJRFK7","recipient_cage":"4ZXC9","recipient_city":"CHEEKTOWAGA","recipient_state":"NY","sub_name":"Department of Veterans Affairs","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","office_key":"o-36C242","first_action_date":"2026-01-28","last_action_date":"2026-10-08","actions":3,"obligated":"399900.00","current_total_value":"399900.00","potential_total_value":"399900.00","naics":"238210","psc":"Y1DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":4,"description":"528A6-24-612 CONNECT PIVS TO FIRE ALARM SYSTEM","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24226B0016 equals the FPDS solicitation identifier","same awarding office 36C242"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"36C24627Q0114","latest_notice_id":"9464cbfda7004348805568dfa367e88c","title":"5975--INSTALLATION OF PROXIMITY SENSORS FOR AUTOMATIC DOORS","solicitation_number":"36C24627Q0114","notice_type":"o","first_type":"r","first_posted":"2026-11-04","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"238210","psc":"5975","set_aside":null,"state":"NC","county":"37051","county_name":"Cumberland County","city":"3722920","city_name":"Fayetteville","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":"Product purchase (PSC 5975)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"1232SA27Q0021","latest_notice_id":"8c35373e3e5c4e3bb88b3fb51c3ea2c1","title":"Electrical Installation of 5-Station Cubicle and One Single Hotel Desk Arrangement","solicitation_number":"1232SA27Q0021","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12H2","sub_name":"AGRICULTURAL RESEARCH SERVICE","office_key":"o-1232SA","office_name":"USDA ARS AFM APD","naics":"238210","psc":"N059","set_aside":"SBA","state":"WI","county":"55025","county_name":"Dane County","city":"5548000","city_name":"Madison","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"1240LU26Q0132","latest_notice_id":"7772e7cbaf1a46409b142ded751c8ec8","title":"USDA Forest Service - Hebgen Lake District Office Network Cabling and IT Room Improvements","solicitation_number":"1240LU26Q0132","notice_type":"k","first_type":"k","first_posted":"2026-09-24","last_posted":"2026-11-05","notices":4,"due_at":"2026-11-26T00:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1240LU","office_name":"USDA-FS, CSA INTERMOUNTAIN 9","naics":"238210","psc":"N061","set_aside":"SBA","state":"MT","county":"30031","county_name":"Gallatin County","city":"3079525","city_name":"West Yellowstone","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"}],"similar_open_total":42,"indexable":false}