{"canonical":"https://sealedbidder.com/opportunities/36c24225r0019","key":"36C24225R0019","url":"https://sealedbidder.com/opportunities/36c24225r0019","title":"X1DB--New Lease Relocation Carmel CBOC","solicitation_number":"36C24225R0019","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-01-29T22:00:00Z","first_posted":"2025-12-15","last_posted":"2025-12-15","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"place_state":"NY","place_scope":"site","site":null,"place_state_source":"sam_zip","place_evidence":null,"place_county":"36079","place_county_name":"Putnam County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"26036b10c4b845f7a498d3cd79962dcb","title":"X1DB--New Lease Relocation Carmel CBOC","solicitation_number":"36C24225R0019","notice_type":"r","base_type":"r","posted":"2025-12-15","posted_at":"2025-12-15T14:32:45.479Z","due_at":"2026-01-29T22:00:00Z","due_date":"2026-01-29","cancelled":false,"archived":true,"archive_date":"2026-03-30","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/26036b10c4b845f7a498d3cd79962dcb/view","enriched":true,"history":[{"index":3,"title":"X1DB--New Lease Relocation Carmel CBOC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-15T14:32:45.479Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"26036b10c4b845f7a498d3cd79962dcb","solicitation_number":"36C24225R0019"}]}],"latest_notice_id":"26036b10c4b845f7a498d3cd79962dcb","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-12-15","posted_at":"2025-12-15T14:32:45.479Z","created_at":"2025-12-15T14:32:42.221Z","modified_at":"2026-03-31T04:00:07.573Z","response_deadline":{"raw":"2026-01-29T17:00:00-05:00","utc":"2026-01-29T22:00:00Z","date":"2026-01-29","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/26036b10c4b845f7a498d3cd79962dcb/view"},"naics":{"codes":["531120"],"primary":"531120"},"title":"X1DB--New Lease Relocation Carmel CBOC","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-30","archive_type":"auto_custom"},"history":[{"index":3,"title":"X1DB--New Lease Relocation Carmel CBOC","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-12-15T14:32:45.479Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"26036b10c4b845f7a498d3cd79962dcb","solicitation_number":"36C24225R0019"}],"contacts":[{"name":"Charles Bergeman","role":"primary","email":"charles.bergeman@va.gov","phone":"585-393-8395","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"26036b10c4b845f7a498d3cd79962dcb","lineage_id":"26036b10c4b845f7a498d3cd79962dcb","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-19T01:44:15.594940774Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"d3a52ba2f2d99f41bda13b1019a37f6f815792ce62c853604d259dee2496bb04","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-19T01:44:15.594940774Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"The potential lease space selected must be built out for the VA Medical Center to occupy and open a clinic. The Lessor shall procure an Architect/Engineer (AE) to perform a design build for approximately 6500 Net Usable Square Feet for the potential space to be leased. The Lessor and Architect/Engineer shall ensure that the space will meet or exceed the most stringent of the NYS Building Code, NFPA 101 Life Safety Code, NEC and any local applicable building codes.\nThe AE shall incorporate the VA provided preliminary proposed layout in the design phase. This layout shall be used as the basis-of-design starting point. It is expected that through the design phase meetings with the VA, these will be modified to suit the VA needs.\nProvide labor all new materials, fixtures, tools, equipment and Architect-Engineer (AE) services necessary for design and construction of a fully functional Community based Outpatient Clinic at Carmel, NY.\nThe Lessor shall:\n1. Ensure that the Architect/Engineer (AE) performs a design build of the space per the layout approved by VA.\na. The AE shall provide the 35%, 65% and 100% submission drawings to the VA COR for approval.\nb. AE shall provide submittals of all construction materials to be used within the build out of the space to the VA COR for approval.\n2. The space shall be built out to include but not limited to the following areas. Refer to the space Configuration plan for the list of proposed rooms.\na. Reception Area\ni. Including sliding windows for patient communication both sides of angled windows\nii. Counter space for patients and employees at window\niii. One of the windows shall be at an ADA approved height counter.\nb. Waiting Area to accommodate a minimum of 20 patients and set up for cable TV.\nb. Vestibule area\nc. Staff Room with kitchenette\ni. Including Stainless steel sink and faucet\nii. Base and Wall cabinets\niii. (3) dedicated 20-amp outlets for small appliances\niv. 1 dedicated 20-amp outlet each for refrigerator and Microwave oven.\nd. ADA restrooms\ni. Restrooms shall have mirrors installed above sink\nii. Exhaust fans shall be installed in restrooms that activate with lights\niii. Provide diaper changing station and nurse call system which shall activate an alarm at the reception desk and a strobe light with the words  HELP  outside the restroom.\ne. 1 Optometry exam room with 2 lighting controls\ni. 2  x 2  Fluorescent light fixtures with toggle switch\nii. High hat light fixtures with dimming capabilities and dimmer switch\nf. 1 Visual Fields room\ni. 2  x 2  Fluorescent light fixtures with toggle switch\nii. High hat light fixtures with dimming capabilities and dimmer switch\ng. Medical and Office supplies Storage Room with shelving\nh. Phlebotomy Lab Suite with Restroom\ni. Conference room\ni. Conference room shall have plumbing roughed in for future sink installations.\nii. Build sheetrock wall enclosing the back side of the mailboxes on existing wall in front conference room.\nj. Medical offices\nk. Data/Phone Room\ni. Install dedicated room air conditioner to cool communication equipment maintaining year-round temperature between 68 - 72 degrees F. Room requires cooling year-round due to sensitive equipment.\nii. Thermostatically controlled Exhaust fan\niii. Shall have a 1-hour fire rated construction rating\niv. Shall have a 1-hour fire rated door with self-closer and self-latching hardware\nl. Hazardous material storage area\nm. Copy Room and Office supplies storage with shelving\nn. Janitorial closet\ni. Closet shall have floor mounted service/mop sink\nii. Shall have a wall mounted janitorial faucet installed\niii. Shall have a 1 hour fire rated construction rating\niv. Shall have a 1-hour fire rated door with self-closer and self-latching hardware\nv. Thermostatically controlled exhaust with manual by-pass switch\no. Medical Exam Rooms\np. Women s health Suites\nq. Dirty room equipped with stand-alone stainless sink with faucets and negative air pressure and shelving\nr. Clean room with shelving and Positive pressure\ns. Wheelchair storage and Coat closet with sliding door\nt. Patient Education and Conference-Video-Telehealth rooms\nu. Touch down / Swing Office room\n3. Provide and install chilled water bottling stations.\nGeneral Notes\nTHE LANDLORD SHALL BE SOLELY RESPONSIBLE FOR THE MANAGEMENT, PROFESSIONAL DESIGN, AND CONSTRUCTION, INCLUDING ALL LABOR, EQUIPMENT, MATERIALS, AND INSPECTION, TO MEET REQUIREMENTS OF THE CONTRACT.\nTHE AE SHALL FURNISH A DESIGN PACKAGE TO INCLUDE PLANS, DETAILS, SECTIONS, ELEVATIONS, SITE-VISITS AND RELATED INFORMATION AS REQUIRED BY THE CONTRACT. THE DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST NFPA 101 LIFE SAFETY CODE, UNIFORM PLUMBING CODE (UPC), NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARD, AMERICAN DISABILITY ACT (ADA) COMPLIANCE, VA SPECIFICATIONS AND STANDARDS, AND LOCAL AND CITY CODES. IN THE EVENT THERE IS CONFLICT BETWEEN ANY OF THE STANDARDS/CODES, THE MORE STRINGENT STANDARD/CODE SHALL APPLY.\nTHE AE SHALL HAVE THE CAPABILITY OF COMPUTER-AIDED-DESIGN (CAD). THE CAD PROGRAM USED BY THE AE IN DESIGNING AND DRAFTING THIS PROJECT SHALL BE ABLE TO INTERFACE WITH THE CAD SYSTEM USED BY VA FACILITIES MANAGEMENT/ENGINEERING SERVICE. IN THE FINAL SUBMISSION, THE AE SHALL SUBMIT BOTH HARD COPY DRAWINGS AND CDS CONTAINING ALL DRAWINGS TO THE VA COR.\nTHE AE SHALL USE  MICROSOFT WORD  TO PREPARE SPECIFICATIONS. IN THE FINAL SUBMISSION, THE AE SHALL SUBMIT HARDCOPY SPECIFICATIONS TO THE VA. THE VA MASTER SPECIFICATIONS MAY BE OBTAINED FROM VA COR (HTTP://WWW.CFM.VA.GOV/TIL/SPEC.ASP).\nTHE VA SHALL PROVIDE THE AE THE CONCEPTUAL DESIGN, (ATTACHED SKETCH), AND BASED UPON THAT, THE AE SHALL SUBMIT A CONSTRUCTION DOCUMENT DESIGN SUBMISSION. THE AE SHALL SUBMIT (1) FULL SIZE, (1) HALF SIZE, AND (1) ELECTRONIC COPY OF THE DRAWINGS AND ONE (1) SET OF EDITED SPECIFICATIONS. THE AE SHALL SUBMIT (1) FULL SIZE AND (1) ELECTRONIC COPY OF THE FINAL AS-BUILT DRAWINGS. THE CONSTUCTION DRAWINGS SHALL BE SIGNED AND SEALED BY PROFESSIONAL ENGINEER.\nALL SUBMITTALS FOR MATERIAL AND EQUIPMENT SHALL BE APPROVED BY THE VA PRIOR TO INSTALLATION\nFINAL DESIGN AND RECORD DRAWINGS, CAD AND PDF ON DVD\nTHE CONTRACTOR SHALL COMPLY WITH ALL OSHA CONSTRUCTION SAFETY GUIDELINES.\nALL SAFETY VIOLATIONS CITED BY VA SAFETY ENGINEER SHALL BE CORRECTED PRIOR TO\nOCCUPANCY.\nSUPPLY THE VA WITH A COMPLETE CERTIFICATE OF OCCUPANCY UPON ACCEPTANCE OF SPACE.\n  APPLY AND OBTAIN ALL REQUIRED BUILDING PERMITS.\n  ALL SUBMITTALS FOR MATERIAL AND EQUIPMENT SHALL BE APPROVED BY THE VA PRIOR TO INSTALLATION\n  FINAL DESIGN AND RECORD DRAWINGS, CAD AND PDF ON DVD\n  PARKING SPACES RESERVED FOR VA SHALL ONLY INDICATE AS  RESERVED  AND NOT IDENTIFY AS VA OR GOVERNMENT\nArchitectural Notes\nBUILD-OUT SHALL BE COMPLIANT WITH ALL NYS BUILDING AND LOCAL MUNICIPAL CODES, NFPA 101 AND NEC.\nPROVIDE LIFE SAFETY DRAWING FOR REVIEW BY VA LIFE SAFETY ENGINEER\nINCORPORATE A COVERED PATIENT DROP-OFF AREA AS WELL AS HANDICAP ACCESSIBILITY IN THE DESIGN PHASE.\nIT IS ANTICIPATED THAT THE DESIGN WILL PROVIDE A  HEALING  ENVIRONMENT AND THE COLOR SELECTION AND MATERIAL FINISHES WILL COMPLEMENT THIS. THE AE SHALL COORDINATE THE FINISH COLORS AND MATERIALS WITH THE VA FOR APPROVAL.\nCUT SIDEWALK CURB FOR HANDICAP AND PROVIDE RAMP AND PAINT CURBS YELLOW\nPROVIDE A MINIMUM 30 PARKING SPACES AS CLOSE AS POSSIBLE TO THE CLINIC ENTRANCE. PARKING SPACES RESERVED FOR VA SHALL ONLY INDICATE AS  RESERVED  AND NOT IDENTIFY AS VA OR GOVERNMENT\nPROVIDE SIGNAGE   STREET (LIT PYLON/MARQUEE) AND LIT BUILDING FAÃ‡ADE\nPROVIDE EXTERIOR ON BUILDING FAÃ‡ADE, DOUBLE-SIDED ILLUMINATED SIGNAGE AS PER VA SUPPLIED LOGO.\nPROVIDE DIRECTIONAL SIGNAGE IN CORRIDOR OUTSIDE THE CLINIC SPACE\nINTERIOR ROOM SIGNAGE SHALL HAVE TYPE H (TAKEFORM) DISPLAYING SERVICE AND ROOM NUMBER, EXCEPT FIXED ROOMS SUCH AS RESTROOMS, CONFERENCE ROOMS, RECEPTION, ETC. (CONFIRM IF THESE DON T REQUIRE # S)\nBUILDING AND SUITE ENTRANCE DOORS SHALL BE EQUIPPED WITH FULLY AUTOMATIC DOOR OPERATORS\nSAFETY GLASS FOR SUITE ENTRY DOOR WITH BUSINESS HOURS SIGNAGE\nSTORE FRONT GLASS/WINDOWS IF REQUIRED W/SIGNS   HOURS OF OPERATION\nPROVIDE REINFORCEMENT FOR 60  TV AND INSTALL VA PROVIDED TV S\nALL WALL FRAMING SHALL BE 3 5/8  METAL STUDS.\nINSTALL MINIMUM 5/8\" GYPSUM BOARD SHEATHING AT STUDS.\nALL ROOMS CONSTRUCTED SHALL BE BUILT WITH SOUND PROOFING MATERIALS INCLUDING CEILING TILES TO ENSURE PATIENT PRIVACY WITHIN THE ROOM. WALL R-VALUE SHALL BE DESIGNED TO A MINIMUM OF R-21.\nDOORS AND WINDOWS\nALL WINDOWS SHALL HAVE LAMINATED GLASS WITH A U-VALUE BETWEEN 0.28 AND 0.30 AND ALSO INCORPORATE VA SECURITY REQUIREMENTS. THE WINDOWS SHALL HAVE BUILT-IN SHADES.\nALL DOORS SHALL BE OF SOLID CONSTRUCTION. MEDICAL WASTE, JANITOR S CLOSET, DATA/PHONE CLOSET AND MECHANICAL/ELECTRICAL ROOMS SHALL BE SELF-CLOSING AND SELF-LATCHING.\nCORRIDOR DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE WITH CLEARANCE NOT EXCEEDING 1 INCH FROM BOTTOM OF DOOR TO THE FINISHED FLOOR.\nHALLWAY DOORS SHALL HAVE A GLASS WINDOW IN UPPER SECTION TO ALLOW A LINE OF SIGHT WHILE OPENING DOOR.\nDOOR HARDWARE SHALL BE ADA COMPLIANT AND COMPLY WITH NFPA 101 REQUIREMENTS.\nDOOR LOCKSETS SHALL HAVE REPLACEABLE CORES AND MANUFACTURED BY  BEST, CORBIN RUSSWIN, OR APPROVED EQUAL. LOCKSETS SHALL BE ADA AND NFPA 101 COMPLIANT.\nLOCKSET FUNCTIONS SHALL BE COORDINATED AND APPROVED BY VA.\nLOCKSETS SHALL BE SINGLE MOTION EGRESS COMPLIANT AND SHALL BE ALL KEYED ALIKE, EXCEPT FOR THE DATA/PHONE ROOM WHICH SHALL COMPLY WITH VA SECURITY GUIDELINES.\nALL HALLWAY DOORS SHALL HAVE A PUSH BUTTON LOCK AND KEY SET INSTALLED WITH A DOOR CLOSER AND SELF LATCHING HARDWARE. DOOR CLOSERS SHALL HAVE A TWO POSITION SETTING TO ALLOW DOOR TO HOLD OPENAND/OR AUTOMATICALLY CLOSE.\nALL DOOR LOCKS SHALL WORK ON A COMMON KEY, EXCEPT FOR THE DATA CLOSET, PYXIS ROOM, AND A FEW OTHER ROOMS. COORDINATE WITH THE VA COR\nSPECIFY PRIVACY INDICATOR LOCKSETS FOR BATHROOMS\nBLINDS SHALL BE APPROVED BY VA\nKEYWAY SHOULD BE BEST (FOR MONTROSE) OR CORBIN RUSSERT (FOR CP)\nCUT EXTRA 25 KEYS FOR CLINIC ENTRY, EXAM ROOMS AND 5 SETS FOR DATA CLOSET AND PYXIS ROOMS\nHALLWAY DOORS SHALL HAVE A GLASS WINDOW IN UPPER SECTION TO ALLOW A LINE OF SIGHT WHILE OPENING DOOR.\nHAZMAT STORAGE, EMS CLOSETS, PHONE/DATA CLOSET AND MECHANICAL/ELECTRICAL ROOMS SHALL HAVE SOLID CORE DOOR WITH SELF-LATCHING AND CLOSING HARDWARE INSTALLED\nALL CORRIDOR DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE, WITH CLEARANCE NOT EXCEEDING 1 INCH FROM BOTTOM OF DOOR\nPERMANENT WALL PARTITIONS (RESTROOMS, JANITOR CLOSET, DATA CLOSET SHALL EXTEND FROM STRUCTURAL SLAB TO STRUCTURAL CEILING SLAB AND SHALL BE FIRE RATED.\nFOR ALL OTHER ROOMS, EXTEND WALLS 8\" MINIMUM ABOVE DROP CEILING HEIGHT.\nALL WALLS SHALL BE COVERED WITH ONE COAT OF PRIMER AND TWO COATS OF LATEX FINISH PAINT. THE COLOR OF THE PAINT IS TO BE APPROVED BY THE VA COR PRIOR TO ANY PAINT BEING APPLIED TO WALLS.\nALL SINGLE OCCUPANCY REST ROOMS SHALL HAVE AN ADA COMPLIANT PUSH BUTTON LOCK AND KEY SET INSTALLED.\nRECEPTION AREA SHALL HAVE WINDOWS INSTALLED ON BOTH SIDES OF \"V\" SHAPED WALLS. WINDOWS SHALL BE A SLIDING WINDOW WITH COUNTERTOP FOR THE RECEPTIONIST AND PATIENT. ONE OF THE WINDOWS SHALL HAVE THE COUNTERTOP AT AN ADA HEIGHT.\nALL OPEN PENETRATIONS FROM STORAGE, MECHANICAL AND SUITE TO SUITE SHALL BE FIRE STOPPED.\nTHE FRONT ENTRANCE DOORWAY(S) SHALL BE SIMILAR TO AN ALUMINUM AND GLASS STOREFRONT WITH HANDICAP ACCESSIBLE AUTOMATIC DOOR OPENERS.\nALL FLOORING SHALL BE SOLID VINYL TILE (SVT). THERE SHALL BE COVE BASE MEETING THE SVT TO THE FINISHED WALL.\nCONTRACTOR SHALL INSTALL DROP CEILING TO A DETERMINED HEIGHT APPROVED BY THE VA COR AND SHALL USE SOUNDPROOF CEILING TILES.\nOPTOMETRY ROOM SHALL BE AT LEAST 16 FEET LONG\nPROVIDE SCHEDULE SHOWING AREAS OF ALL ROOMS AND ALSO ON FLOOR PLAN DRAWING\nPROVIDE SCHEDULE FOR DOOR SIZES, CONSTRUCTION AND FIRE RATING\nPROVIDE SCHEDULE DULE OF FLOORING (REFER TO GOSHEN BUILDOUT) SHOWING TYPE OF FLOORING FOR EACH ROOM AND ASSOCIATED PATTERN\nPROVIDE SCHEDULE FOR PAINT, SHOWING COLOR, TYPE, MANUFACTURER AND STYLE\nPROVIDE SCHEDULE OF ALL AREAS IN SQUARE FOOTAGE, INCLUDING VESTIBULE, WAITING AND ALL OTHER ROOMS WITHIN THE CLINIC SPACE\nDATA ROOM-WALL EXTENDS UP TO DECK-2 SETS OF LOCKSETS-AC-2 X3  FINISHED 1/2'  PAINTED PLYWOOD- RACK FOR PATCH PANELS AND SWITCHES-PATCH PANELS\nPROVIDE HANDRAILS ON WALL\nCORRIDORS SHALL BE BETWEEN 44-48 \nFURNITURE\nPROVIDE LAYOUT OF EQUIPMENT AND FURNITURE TO PINPOINT LOCATION OF POWER AND DATA OUTLETS\nBACKING SUPPORT SHALL BE REQUIRED FOR ALL FURNITURE AND EQUIPMENT.\nCASEWORK FOR ALL ROOMS EXCEPT DATA CLOSET, MR, CONFERENCE ROOM, TOUCHDOWN ROOM, STORAGE ROOM, CLEAN ROOM, V-TEL ROOM\nCASEWORK SHALL HAVE BASE AND WALL CABINETS WITH INTEGRATED STAINLESS SINK AND FAUCET IN ALL EXAM ROOMS, WOMEN S HEALTH, BLOOD LAB (CLEAN AND DIRTY COUNTERS W/SEPARATION BETWEEN THEM-USE PJ LAYOUT) AND DIRTY ROOM. ALL DRAWERS AND CABINET DOORS SHALL HAVE KEY LOCKS INSTALLED\nCASEWORK COUNTERTOP TO BE CORIAN-USE POUGHKEEPSIE SPEC FOR CABINETS\nRECEPTION AREA COUNTERTOPS TO BE CORIAN\nLOCKERS IN STAFF AREA-USE POUGHKEEPSIE SPEC-LOCKERS.COM- 12 LOCKERS\nElectrical Notes (Power-Lighting-Data-Communication)\nMINIMUM WIRE SIZE SHALL BE 12 GAGE AND CIRCUIT BREAKER SHALL BE 20 AMPS\nLAB AND PODIATRY SHALL HAVE EMERGENCY LIGHT BACKUP\nROOMS WITH NO WINDOWS SHALL HAVE EMERGENCY LIGHTS\nNURSE CALL   CALL FOR AID (LOCAL W/STROBE)   HARDWIRED   CONTROL AT RECEPTION AND LOCAL\nSEPARATE CAT6 RUNS FOR WALL PHONES AND COMPUTERS\nEACH RUN TO EACH ROOM SHALL HAVE A MINIMUM OF 3 CAT6 CABLES-EACH CABLE SHALL BE TERMINATED ON DIFFERENT WALLS OF THE ROOM\nPROVIDE CAT6 SHIELDED CABLE WITH ASSOCIATED SHIELDED CONNECTORS FOR VA PROVIDED WIFI ROUTERS THROUGHOUT THE CLINIC. A MINIMUM OF 12 ROUTERS WILL BE PROVIDED.\nPROVIDE (2) 3 PORT DATA OUTLETS IN EACH OF THE ROOMS\nFOR VISUAL FIELDS   3-PORT JACK (2+1)   CAMERA-1 PORT / EQUIPMENT-1 PORT\nFOR CVT ROOM   2-PORT JACK (NETWORK)\nWALL PHONES FOR ALL ROOMS   1 CAT 6E DROP FOR WALL-HUNG PHONE   ASK MARCOS FOR # OF PHONES\nSPECIFY DEDICATED OUTLETS (PYXIS, DATA, SHREDDER, STAFF LOUNGE (3-4)) AND INSTALLATION OF OUTLETS AS PER NEC CODE FOR MEDICAL OFFICES, I.E. OUTLET EVERY 6 FEET FROM EACH OTHER.\nPOWER OUTLETS FOR CABLE TV S\nINSTALL SUFFICIENT NUMBER OF DEDICATED OUTLETS (AT LEAST 5) BY KITCHEN COUNTERTOP FOR ALL APPLIANCES\nLIGHT FIXTURES SHALL BE 2 X2  LED WITH T8 LAMPS AND HIGH EFFICIENCY BALLASTS. OCCUPIED SPACES SHALL BE DESIGNED TO 50 FOOT CANDLES (FC) AND NON-OCCUPIED SPACES SHALL BE DESIGNED TO 10 FC MINIMUM. NON-OCCUPIED SPACES SHALL BE CONTROLLED BY AN INFRARED TYPE OCCUPANCY SENSOR AND OCCUPIED SPACES SHALL BE CONTROLLED BY TOGGLE SWITCHES.\nMINIMUM OF (4) LIGHT FIXTURES PER ROOM (2  X 2 ) WITH ENOUGH FOOT CANDLES ESPECIALLY PODIATRY\nLIGHT FIXTURES LOCATED NEAR FRONT AND REAR DOOR SHALL BE HARD WIRED TO A DEDICATED CIRCUIT, ENSURING ENTRY AND EXIT PASSAGE LIGHTING IS ALWAYS ON.\nEMERGENCY EGRESS LIGHTING AND ILLUMINATED EXIT SIGNS SHALL HAVE 90 MINUTES MINIMUM BATTERY BACKUP.\nALL WIRING FOR DATA AND TELECOMMUNICATIONS SHALL BE IN CONDUIT. LEAVE ABOUT 10-12 FEET OF EXCESS CABLES COILED IN THE DATA ROOM.\nEVERY ROOM SHALL HAVE A MINIMUM OF ONE 4-PORT DATA/VOICE RECEPTACLE. EXAM ROOMS, OFFICES, CONFERENCE ROOMS, WAITING AREA AND RECEPTION SHALL HAVE THREE 4-PORT DATA RECEPTACLE. EACH RECEPTACLE SHALL HAVE SIX CAT 6 CABLES AND SHALL BE LOCATED WITHIN 12  FROM 110 VOLT RECEPTACLE. BOTH CABLE ENDS SHALL BE LABELED.\nTHE DATA/PHONE ROOM WALL SURFACES SHALL BE LINED WITH FIRE RETARDANT PLYWOOD EXTENDING FROM 6  A.F.F. TO 8 -6  HIGH AND PAINTED BLACK, ROUTING OF CABLES SHALL BE IN CABLE TRAYS AND LOCATED ABOVE OR ADJACENT TO CORRIDORS AND BE ACCESSIBLE FROM A LADDER PLACED IN THE CORRIDOR FOR FUTURE MAINTENANCE.\nCABLES FOR CABLE TV SHALL BE PROVIDED IN CONDUIT FROM POINT OF ENTRY INTO THE CLINIC TO WAITING AREA AND CONFERENCE ROOMS. 110 VOLT RECEPTACLES SHALL BE PROVIDED TO POWER THE CABLE BOXES.\nCONTRACTOR SHALL ALSO INSTALL CONDUIT FOR ALL DATA AND TELECOMMUNICATION CABLE PULLS FROM THE UTILITY ROOM TO DATA ROOM CLOSET. ALL WIRING SHALL CONFORM TO THE BUILDING CODES LISTED ABOVE.\nINSTALL AND WIRE ALL ELECTRICAL OUTLETS PER VA PROPOSED LAYOUT.\nINSTALL AND WIRE ALL PHONE AND DATA OUTLETS PER VA PROPOSED LAYOUT, ALL WIRING SHALL BE CAT 6. A TRIPLE CONNECTION SHALL BE PULLED TO EACH LOCATION.\nTERMINATE DATA LINE IN ALL ROOMS AND LEAVE A 12 - 15FT NON-TERMINATED CABLE COIL IN THE DATA ROOM. ALL CABLES TO BE LABELED ON BOTH ENDS OF WIRE PULL\nALL OUTLETS SHALL BE HOSPITAL GRADE 20 AMP CIRCUITS UNLESS OTHERWISE SPECIFIED\nLIGHT FIXTURES LOCATED NEAR FRONT AND REAR DOOR SHALL BE HARD WIRED TO A DEDICATED CIRCUIT ENSURING ENTRY AND EXITING PASSAGE LIGHTING IS ALWAYS ON\nSHALL PROVIDE AND INSTALL BATTERY BACKUP (90 MINUTES MINIMUM) EMERGENCY EGRESS LIGHTING\nSHALL PROVIDE AND INSTALL ILLUMINATED EMERGENCY EXIT SIGNS WITH 90 MINUTES BATTERY BACKUP\nLAB AND PODIATRY SHALL HAVE EMERGENCY LIGHT BACKUP\nROOMS WITH NO WINDOWS SHALL HAVE EMERGENCY LIGHTS\nNURSE CALL   CALL FOR AID (LOCAL W/STROBE) - HARDWIRED\nPOWER OUTLETS EVERY 6 FEET   PER NEC\nKIOSK   DATA AND POWER\nHEALTHY VET DESK   DATA AND POWER (CONFIRM W/SHATHA)\nEACH RUN TO EACH ROOM SHALL HAVE A MINIMUM OF 3 CAT6 CABLES-EACH CABLE SHALL BE TERMINATED ON DIFFERENT WALLS OF THE ROOM\nPYXIS/EKG   DEDICATED CIRCUITS\nSPECIFY DEDICATED OUTLETS FOR DATA, SHREDDER, STAFF LOUNGE (3-4)) AND INSTALLATION OF OUTLETS AS PER NEC CODE FOR MEDICAL OFFICES, I.E. OUTLET EVERY 6 FEET FROM EACH OTHER.\nDATA CLOSET   PHONES:\nPROVIDE WIRING IN CONDUIT FOR ALL CABLES FROM BUILDING DEMARCATION ROOM TO THE DATA CLOSET\nFIRE STOP ALL PENETRATIONS IN CEILING WALLS AND FLOORS.\nPROVIDE 2  X 3 - Â¾  PAINTED PLYWOOD ON WALL PROVIDE SMOKE DETECTOR INSIDE DATA CLOSET\nPROVIDE LAYOUT OF EQUIPMENT AND FURNITURE TO PINPOINT LOCATION OF POWER AND DATA OUTLETS\nRACK FOR PATCH PANELS AND NETWORKING EQUIPMENT\nDEDICATED OUTLETS (3)   20AMP\nDEDICATED AC UNIT\nALARM ON THE OUTSID INSTALL HI-TEMP LOCAL ALARM W/FEATURE TO SILENCE AND BYPASS. INSTALL STROBE AND HORN OUTSIDE W/SIGN  HI TEMP \nBACKUP THERMOSTATICALLY CONTROLLED EXHAUST FAN W/AUDIO AND VISUAL ALARM IF IT COMES ON AND SILENCE BUTTON\nCAT6 CABLES FOR MINIMUM OF 8 WI-FI ROUTERS   LOCATION TO BE DETERMINED BY VA\nCAT6 CABLE DROPS FOR EACH ROOM   2 FOR DATA OUTLET AND 1 FOR WALL PHONE\nALL CAT6 CABLES SHALL BE PLENUM RATED OR IN CONDUIT.\nPlumbing / HVAC Notes\nUNLESS OTHERWISE SPECIFIED, ALL SINKS SHALL HAVE WRIST BLADE CONTROL HANDLES, HOT AND COLD WATER SUPPLY AND PROPER DRAINAGE.\nSINKS LOCATED WITHIN RESTROOMS SHALL BE ADA COMPLIANT. FAUCET HARDWARE SHALL BE ADA COMPLIANT. FOOT PEDALS ARE NOT REQUIRED. ALL TOILETS INSTALLED SHALL BE OF PROPER ADA HEIGHT.\nSINK LOCATED IN THE STAFF ROOM SHALL BE A DOUBLE STAINLESS STEEL SINK WITH KITCHEN FAUCET AND SPRAY HOSE. FOOT PEDALS ARE NOT REQUIRED.\nPLUMBING FIXTURES SHALL BE  LOW FLOW  TYPE AND THE HOT WATER SYSTEM SHALL BE LOOPED FOR RECIRCULATION. ELECTRONIC FLUSH VALVES AND FAUCETS SHALL BE PROVIDED FOR ALL FIXTURES. EXAM ROOM SINKS SHALL HAVE GOOSENECK SPOUTS AND PEDAL OPERATED FAUCETS.\nPROVIDE HI-RISE TOILETS AND COVERS FOR PIPING.\nPROVIDE CHILLED WATER BOTTLING STATIONS IN WAITING AREA, WITH POWER, COLD WATER SUPPLY AND DRAINAGE.\nPROVIDE FILTRATION AND MAINTENANCE FOR REFRIGERATED WATER BOTTLING STATIONS.\nJANITORIAL CLOSET SHALL HAVE A FLOOR MOUNTED MOP SINK INSTALLED CONNECTED TO DRAINAGE SYSTEM. THERE SHALL BE A WALL MOUNTED JANITORIAL FAUCET INSTALLED WITH HOT AND COLD WATER SERVICE.\nALL ROOMS OF THE SUITE SHALL HAVE HVAC DIFFUSERS AND RETURNS PROPERLY SIZED FOR THE ROOM.\nTHE HVAC SYSTEM SHALL BE DESIGNED TO PROVIDE INDIVIDUALLY CONTROLLED THERMOSTATS EACH WITH ITS OWN VAV FOR ALL OCCUPIED SPACES (EXAM TYPE ROOMS, RECEPTION, WAITING AREA). UNOCCUPIED SPACES (RESTROOMS, STORAGE, JANITOR, SOILED LINEN ROOM) MAY BE GROUPED WITH NO MORE THAN 4 ROOMS ON ANY ONE VAV. SUPPLY, EXHAUST AND RETURN AIR SYSTEMS SHALL BE DUCTED.\nEXHAUST SYSTEM SHALL BE REQUIRED FOR RESTROOMS, WAITING AREA, DATA ROOM AND OTHERS.\nPOSITIVE AND NEGATIVE AIR PRESSURES FOR CLEAN AND DIRTY ROOMS\nAIR CHANGES REQUIREMENT   TAB REPORT (TESTING AND BALANCING)\nMAKE PROVISION FOR FRESH OUTDOOR AIR\nPROVIDE (4) SEPARATE ZONES FOR FRONT (RECEPTION AND LOBBY), REAR AND ONE EACH FOR THE 2 INTERIOR CORRIDORS HYDRONIC SYSTEM W/HUMIDIFIER\nPROVIDE Testing and Balancing reports BY CERTIFIED CONTRACTOR\nPROVIDE DUCT LEAKAGE INSPECTION AND REPORT\nCLEAN AND DIRTY ROOMS   POSITIVE AND NEGATIVE AIR\nFire Sprinkler and Fire Alarm Notes\nBUILDING SHALL BE FULLY SPRINKLERED AND THE DESIGN MUST BE CERTIFIED BY AN INDEPENDENT NEW YORK STATE LICENSED FIRE PROTECTION ENGINEER AND APPROVED BY THE LOCAL FIRE DEPARTMENT AND THE VA.\nCONTRACTOR SHALL INSTALL FIRE SPRINKLER SYSTEM AS PER THE NFPA 13 AND LIFESAFETY DEVICES.\nTHE FIRE ALARM SYSTEM SHALL COMPLY WITH THE LOCAL FIRE DEPARTMENT AND SHALL BE TIED TO THE HVAC SYSTEM TO SHUT THE UNIT DOWN. BATTERY BACKUP SHALL BE PROVIDED.\nPROVIDE FULLY RECESSED FIRE EXTINGUISHER CABINETS\nPROVIDE SHALL PROVIDE AND INSTALL APPROVED FIRE EXTINGUISHERS IN CABINETS\nALL PENETRATIONS FROM MECHANICAL ROOMS, STORAGES, JANITORIAL AND/OR SUITE TO SUITE SHALL BE PROPERLY FIRE SEALED\nSecurity System Notes\nTHE BURGLAR ALARM SYSTEM SHALL DETECT ENTRY AT EITHER FRONT OR REAR ENTRY/EXIT DOORS. AND ALSO DETECT BROKEN GLASS IN AREAS WHICH ARE RELATIVELY ACCESSIBLE. THE SYSTEM SHALL INTERFACE WITH THE LOCAL POLICE DEPARTMENT AS WELL AS THE VA POLICE DEPARTMENT. ALL SECURITY WIRING SHALL BE IN CONDUIT.\nAN ELECTRONIC PERSONNEL PROTECTION SYSTEM SHALL BE A DURESS-PANIC ALARM TYPE. EMERGENCY BUTTONS SHALL BE LOCATED AT THE RECEPTION DESK. A CCTV SYSTEM WITH AN NVR SHALL BE EMPLOYED TO MONITOR ALL EXTERIOR DOORS AND MAIN LOBBY.\nPROVIDE SECURED MAILBOX\nCONTRACTOR SHALL HAVE A BURGLAR ALARM SYSTEM INSTALLED FOR THE OCCUPIED SPACES\nA. DETECT ENTRY ON EITHER FRONT OR REAR ENTRY/EXIT DOORS\nB. DETECT BROKEN WINDOW ON AREAS WERE RELATIVELY ACCESSIBLE\nPROVIDE INTRUSION, PANIC AND CCTV\n  FSL LEVEL 2   CCTV-PANIC-INTRUSION   COORDINATE WITH VA VENDOR\n  FSL LEVEL 3 - BOLLARDS   VA SPEC (4000 LBS)\nTESTING:\n  PRIOR TO OCCUPANCY, PROVIDE THE FOLLOWING INSPECTIONS, TESTS AND DETAILED REPORTS. THE INSPECTION AND TESTING AGENCIES SHALL BE AN INDEPENDENT THIRD PARTY AND SHALL BE LICENSED AND CERTIFIED BY NEW YORK STATE. A MINIMUM OF 3 AGENCIES SHALL BE SUBMITTED TO THE VA COR FOR REVIEW AND APPROVAL AND SELECTION OF THE AGENCY.\n1. CERTIFICATE OF OCCUPANCY\n2. DUCT LEAKAGE TEST\n3. TESTING AND BALANCING\n4. AIR QUALITY TESTING\n5. WATER TESTING\n6. FIRE INSPECTION","text":"The potential lease space selected must be built out for the VA Medical Center to occupy and open a clinic. The Lessor shall procure an Architect/Engineer (AE) to perform a design build for approximately 6500 Net Usable Square Feet for the potential space to be leased. The Lessor and Architect/Engineer shall ensure that the space will meet or exceed the most stringent of the NYS Building Code, NFPA 101 Life Safety Code, NEC and any local applicable building codes.\nThe AE shall incorporate the VA provided preliminary proposed layout in the design phase. This layout shall be used as the basis-of-design starting point. It is expected that through the design phase meetings with the VA, these will be modified to suit the VA needs.\nProvide labor all new materials, fixtures, tools, equipment and Architect-Engineer (AE) services necessary for design and construction of a fully functional Community based Outpatient Clinic at Carmel, NY.\nThe Lessor shall:\n1. Ensure that the Architect/Engineer (AE) performs a design build of the space per the layout approved by VA.\na. The AE shall provide the 35%, 65% and 100% submission drawings to the VA COR for approval.\nb. AE shall provide submittals of all construction materials to be used within the build out of the space to the VA COR for approval.\n2. The space shall be built out to include but not limited to the following areas. Refer to the space Configuration plan for the list of proposed rooms.\na. Reception Area\ni. Including sliding windows for patient communication both sides of angled windows\nii. Counter space for patients and employees at window\niii. One of the windows shall be at an ADA approved height counter.\nb. Waiting Area to accommodate a minimum of 20 patients and set up for cable TV.\nb. Vestibule area\nc. Staff Room with kitchenette\ni. Including Stainless steel sink and faucet\nii. Base and Wall cabinets\niii. (3) dedicated 20-amp outlets for small appliances\niv. 1 dedicated 20-amp outlet each for refrigerator and Microwave oven.\nd. ADA restrooms\ni. Restrooms shall have mirrors installed above sink\nii. Exhaust fans shall be installed in restrooms that activate with lights\niii. Provide diaper changing station and nurse call system which shall activate an alarm at the reception desk and a strobe light with the words HELP outside the restroom.\ne. 1 Optometry exam room with 2 lighting controls\ni. 2 x 2 Fluorescent light fixtures with toggle switch\nii. High hat light fixtures with dimming capabilities and dimmer switch\nf. 1 Visual Fields room\ni. 2 x 2 Fluorescent light fixtures with toggle switch\nii. High hat light fixtures with dimming capabilities and dimmer switch\ng. Medical and Office supplies Storage Room with shelving\nh. Phlebotomy Lab Suite with Restroom\ni. Conference room\ni. Conference room shall have plumbing roughed in for future sink installations.\nii. Build sheetrock wall enclosing the back side of the mailboxes on existing wall in front conference room.\nj. Medical offices\nk. Data/Phone Room\ni. Install dedicated room air conditioner to cool communication equipment maintaining year-round temperature between 68 - 72 degrees F. Room requires cooling year-round due to sensitive equipment.\nii. Thermostatically controlled Exhaust fan\niii. Shall have a 1-hour fire rated construction rating\niv. Shall have a 1-hour fire rated door with self-closer and self-latching hardware\nl. Hazardous material storage area\nm. Copy Room and Office supplies storage with shelving\nn. Janitorial closet\ni. Closet shall have floor mounted service/mop sink\nii. Shall have a wall mounted janitorial faucet installed\niii. Shall have a 1 hour fire rated construction rating\niv. Shall have a 1-hour fire rated door with self-closer and self-latching hardware\nv. Thermostatically controlled exhaust with manual by-pass switch\no. Medical Exam Rooms\np. Women s health Suites\nq. Dirty room equipped with stand-alone stainless sink with faucets and negative air pressure and shelving\nr. Clean room with shelving and Positive pressure\ns. Wheelchair storage and Coat closet with sliding door\nt. Patient Education and Conference-Video-Telehealth rooms\nu. Touch down / Swing Office room\n3. Provide and install chilled water bottling stations.\nGeneral Notes\nTHE LANDLORD SHALL BE SOLELY RESPONSIBLE FOR THE MANAGEMENT, PROFESSIONAL DESIGN, AND CONSTRUCTION, INCLUDING ALL LABOR, EQUIPMENT, MATERIALS, AND INSPECTION, TO MEET REQUIREMENTS OF THE CONTRACT.\nTHE AE SHALL FURNISH A DESIGN PACKAGE TO INCLUDE PLANS, DETAILS, SECTIONS, ELEVATIONS, SITE-VISITS AND RELATED INFORMATION AS REQUIRED BY THE CONTRACT. THE DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST NFPA 101 LIFE SAFETY CODE, UNIFORM PLUMBING CODE (UPC), NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARD, AMERICAN DISABILITY ACT (ADA) COMPLIANCE, VA SPECIFICATIONS AND STANDARDS, AND LOCAL AND CITY CODES. IN THE EVENT THERE IS CONFLICT BETWEEN ANY OF THE STANDARDS/CODES, THE MORE STRINGENT STANDARD/CODE SHALL APPLY.\nTHE AE SHALL HAVE THE CAPABILITY OF COMPUTER-AIDED-DESIGN (CAD). THE CAD PROGRAM USED BY THE AE IN DESIGNING AND DRAFTING THIS PROJECT SHALL BE ABLE TO INTERFACE WITH THE CAD SYSTEM USED BY VA FACILITIES MANAGEMENT/ENGINEERING SERVICE. IN THE FINAL SUBMISSION, THE AE SHALL SUBMIT BOTH HARD COPY DRAWINGS AND CDS CONTAINING ALL DRAWINGS TO THE VA COR.\nTHE AE SHALL USE MICROSOFT WORD TO PREPARE SPECIFICATIONS. IN THE FINAL SUBMISSION, THE AE SHALL SUBMIT HARDCOPY SPECIFICATIONS TO THE VA. THE VA MASTER SPECIFICATIONS MAY BE OBTAINED FROM VA COR (HTTP://WWW.CFM.VA.GOV/TIL/SPEC.ASP).\nTHE VA SHALL PROVIDE THE AE THE CONCEPTUAL DESIGN, (ATTACHED SKETCH), AND BASED UPON THAT, THE AE SHALL SUBMIT A CONSTRUCTION DOCUMENT DESIGN SUBMISSION. THE AE SHALL SUBMIT (1) FULL SIZE, (1) HALF SIZE, AND (1) ELECTRONIC COPY OF THE DRAWINGS AND ONE (1) SET OF EDITED SPECIFICATIONS. THE AE SHALL SUBMIT (1) FULL SIZE AND (1) ELECTRONIC COPY OF THE FINAL AS-BUILT DRAWINGS. THE CONSTUCTION DRAWINGS SHALL BE SIGNED AND SEALED BY PROFESSIONAL ENGINEER.\nALL SUBMITTALS FOR MATERIAL AND EQUIPMENT SHALL BE APPROVED BY THE VA PRIOR TO INSTALLATION\nFINAL DESIGN AND RECORD DRAWINGS, CAD AND PDF ON DVD\nTHE CONTRACTOR SHALL COMPLY WITH ALL OSHA CONSTRUCTION SAFETY GUIDELINES.\nALL SAFETY VIOLATIONS CITED BY VA SAFETY ENGINEER SHALL BE CORRECTED PRIOR TO\nOCCUPANCY.\nSUPPLY THE VA WITH A COMPLETE CERTIFICATE OF OCCUPANCY UPON ACCEPTANCE OF SPACE.\nAPPLY AND OBTAIN ALL REQUIRED BUILDING PERMITS.\nALL SUBMITTALS FOR MATERIAL AND EQUIPMENT SHALL BE APPROVED BY THE VA PRIOR TO INSTALLATION\nFINAL DESIGN AND RECORD DRAWINGS, CAD AND PDF ON DVD\nPARKING SPACES RESERVED FOR VA SHALL ONLY INDICATE AS RESERVED AND NOT IDENTIFY AS VA OR GOVERNMENT\nArchitectural Notes\nBUILD-OUT SHALL BE COMPLIANT WITH ALL NYS BUILDING AND LOCAL MUNICIPAL CODES, NFPA 101 AND NEC.\nPROVIDE LIFE SAFETY DRAWING FOR REVIEW BY VA LIFE SAFETY ENGINEER\nINCORPORATE A COVERED PATIENT DROP-OFF AREA AS WELL AS HANDICAP ACCESSIBILITY IN THE DESIGN PHASE.\nIT IS ANTICIPATED THAT THE DESIGN WILL PROVIDE A HEALING ENVIRONMENT AND THE COLOR SELECTION AND MATERIAL FINISHES WILL COMPLEMENT THIS. THE AE SHALL COORDINATE THE FINISH COLORS AND MATERIALS WITH THE VA FOR APPROVAL.\nCUT SIDEWALK CURB FOR HANDICAP AND PROVIDE RAMP AND PAINT CURBS YELLOW\nPROVIDE A MINIMUM 30 PARKING SPACES AS CLOSE AS POSSIBLE TO THE CLINIC ENTRANCE. PARKING SPACES RESERVED FOR VA SHALL ONLY INDICATE AS RESERVED AND NOT IDENTIFY AS VA OR GOVERNMENT\nPROVIDE SIGNAGE STREET (LIT PYLON/MARQUEE) AND LIT BUILDING FAÃ‡ADE\nPROVIDE EXTERIOR ON BUILDING FAÃ‡ADE, DOUBLE-SIDED ILLUMINATED SIGNAGE AS PER VA SUPPLIED LOGO.\nPROVIDE DIRECTIONAL SIGNAGE IN CORRIDOR OUTSIDE THE CLINIC SPACE\nINTERIOR ROOM SIGNAGE SHALL HAVE TYPE H (TAKEFORM) DISPLAYING SERVICE AND ROOM NUMBER, EXCEPT FIXED ROOMS SUCH AS RESTROOMS, CONFERENCE ROOMS, RECEPTION, ETC. (CONFIRM IF THESE DON T REQUIRE # S)\nBUILDING AND SUITE ENTRANCE DOORS SHALL BE EQUIPPED WITH FULLY AUTOMATIC DOOR OPERATORS\nSAFETY GLASS FOR SUITE ENTRY DOOR WITH BUSINESS HOURS SIGNAGE\nSTORE FRONT GLASS/WINDOWS IF REQUIRED W/SIGNS HOURS OF OPERATION\nPROVIDE REINFORCEMENT FOR 60 TV AND INSTALL VA PROVIDED TV S\nALL WALL FRAMING SHALL BE 3 5/8 METAL STUDS.\nINSTALL MINIMUM 5/8\" GYPSUM BOARD SHEATHING AT STUDS.\nALL ROOMS CONSTRUCTED SHALL BE BUILT WITH SOUND PROOFING MATERIALS INCLUDING CEILING TILES TO ENSURE PATIENT PRIVACY WITHIN THE ROOM. WALL R-VALUE SHALL BE DESIGNED TO A MINIMUM OF R-21.\nDOORS AND WINDOWS\nALL WINDOWS SHALL HAVE LAMINATED GLASS WITH A U-VALUE BETWEEN 0.28 AND 0.30 AND ALSO INCORPORATE VA SECURITY REQUIREMENTS. THE WINDOWS SHALL HAVE BUILT-IN SHADES.\nALL DOORS SHALL BE OF SOLID CONSTRUCTION. MEDICAL WASTE, JANITOR S CLOSET, DATA/PHONE CLOSET AND MECHANICAL/ELECTRICAL ROOMS SHALL BE SELF-CLOSING AND SELF-LATCHING.\nCORRIDOR DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE WITH CLEARANCE NOT EXCEEDING 1 INCH FROM BOTTOM OF DOOR TO THE FINISHED FLOOR.\nHALLWAY DOORS SHALL HAVE A GLASS WINDOW IN UPPER SECTION TO ALLOW A LINE OF SIGHT WHILE OPENING DOOR.\nDOOR HARDWARE SHALL BE ADA COMPLIANT AND COMPLY WITH NFPA 101 REQUIREMENTS.\nDOOR LOCKSETS SHALL HAVE REPLACEABLE CORES AND MANUFACTURED BY BEST, CORBIN RUSSWIN, OR APPROVED EQUAL. LOCKSETS SHALL BE ADA AND NFPA 101 COMPLIANT.\nLOCKSET FUNCTIONS SHALL BE COORDINATED AND APPROVED BY VA.\nLOCKSETS SHALL BE SINGLE MOTION EGRESS COMPLIANT AND SHALL BE ALL KEYED ALIKE, EXCEPT FOR THE DATA/PHONE ROOM WHICH SHALL COMPLY WITH VA SECURITY GUIDELINES.\nALL HALLWAY DOORS SHALL HAVE A PUSH BUTTON LOCK AND KEY SET INSTALLED WITH A DOOR CLOSER AND SELF LATCHING HARDWARE. DOOR CLOSERS SHALL HAVE A TWO POSITION SETTING TO ALLOW DOOR TO HOLD OPENAND/OR AUTOMATICALLY CLOSE.\nALL DOOR LOCKS SHALL WORK ON A COMMON KEY, EXCEPT FOR THE DATA CLOSET, PYXIS ROOM, AND A FEW OTHER ROOMS. COORDINATE WITH THE VA COR\nSPECIFY PRIVACY INDICATOR LOCKSETS FOR BATHROOMS\nBLINDS SHALL BE APPROVED BY VA\nKEYWAY SHOULD BE BEST (FOR MONTROSE) OR CORBIN RUSSERT (FOR CP)\nCUT EXTRA 25 KEYS FOR CLINIC ENTRY, EXAM ROOMS AND 5 SETS FOR DATA CLOSET AND PYXIS ROOMS\nHALLWAY DOORS SHALL HAVE A GLASS WINDOW IN UPPER SECTION TO ALLOW A LINE OF SIGHT WHILE OPENING DOOR.\nHAZMAT STORAGE, EMS CLOSETS, PHONE/DATA CLOSET AND MECHANICAL/ELECTRICAL ROOMS SHALL HAVE SOLID CORE DOOR WITH SELF-LATCHING AND CLOSING HARDWARE INSTALLED\nALL CORRIDOR DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE, WITH CLEARANCE NOT EXCEEDING 1 INCH FROM BOTTOM OF DOOR\nPERMANENT WALL PARTITIONS (RESTROOMS, JANITOR CLOSET, DATA CLOSET SHALL EXTEND FROM STRUCTURAL SLAB TO STRUCTURAL CEILING SLAB AND SHALL BE FIRE RATED.\nFOR ALL OTHER ROOMS, EXTEND WALLS 8\" MINIMUM ABOVE DROP CEILING HEIGHT.\nALL WALLS SHALL BE COVERED WITH ONE COAT OF PRIMER AND TWO COATS OF LATEX FINISH PAINT. THE COLOR OF THE PAINT IS TO BE APPROVED BY THE VA COR PRIOR TO ANY PAINT BEING APPLIED TO WALLS.\nALL SINGLE OCCUPANCY REST ROOMS SHALL HAVE AN ADA COMPLIANT PUSH BUTTON LOCK AND KEY SET INSTALLED.\nRECEPTION AREA SHALL HAVE WINDOWS INSTALLED ON BOTH SIDES OF \"V\" SHAPED WALLS. WINDOWS SHALL BE A SLIDING WINDOW WITH COUNTERTOP FOR THE RECEPTIONIST AND PATIENT. ONE OF THE WINDOWS SHALL HAVE THE COUNTERTOP AT AN ADA HEIGHT.\nALL OPEN PENETRATIONS FROM STORAGE, MECHANICAL AND SUITE TO SUITE SHALL BE FIRE STOPPED.\nTHE FRONT ENTRANCE DOORWAY(S) SHALL BE SIMILAR TO AN ALUMINUM AND GLASS STOREFRONT WITH HANDICAP ACCESSIBLE AUTOMATIC DOOR OPENERS.\nALL FLOORING SHALL BE SOLID VINYL TILE (SVT). THERE SHALL BE COVE BASE MEETING THE SVT TO THE FINISHED WALL.\nCONTRACTOR SHALL INSTALL DROP CEILING TO A DETERMINED HEIGHT APPROVED BY THE VA COR AND SHALL USE SOUNDPROOF CEILING TILES.\nOPTOMETRY ROOM SHALL BE AT LEAST 16 FEET LONG\nPROVIDE SCHEDULE SHOWING AREAS OF ALL ROOMS AND ALSO ON FLOOR PLAN DRAWING\nPROVIDE SCHEDULE FOR DOOR SIZES, CONSTRUCTION AND FIRE RATING\nPROVIDE SCHEDULE DULE OF FLOORING (REFER TO GOSHEN BUILDOUT) SHOWING TYPE OF FLOORING FOR EACH ROOM AND ASSOCIATED PATTERN\nPROVIDE SCHEDULE FOR PAINT, SHOWING COLOR, TYPE, MANUFACTURER AND STYLE\nPROVIDE SCHEDULE OF ALL AREAS IN SQUARE FOOTAGE, INCLUDING VESTIBULE, WAITING AND ALL OTHER ROOMS WITHIN THE CLINIC SPACE\nDATA ROOM-WALL EXTENDS UP TO DECK-2 SETS OF LOCKSETS-AC-2 X3 FINISHED 1/2' PAINTED PLYWOOD- RACK FOR PATCH PANELS AND SWITCHES-PATCH PANELS\nPROVIDE HANDRAILS ON WALL\nCORRIDORS SHALL BE BETWEEN 44-48\nFURNITURE\nPROVIDE LAYOUT OF EQUIPMENT AND FURNITURE TO PINPOINT LOCATION OF POWER AND DATA OUTLETS\nBACKING SUPPORT SHALL BE REQUIRED FOR ALL FURNITURE AND EQUIPMENT.\nCASEWORK FOR ALL ROOMS EXCEPT DATA CLOSET, MR, CONFERENCE ROOM, TOUCHDOWN ROOM, STORAGE ROOM, CLEAN ROOM, V-TEL ROOM\nCASEWORK SHALL HAVE BASE AND WALL CABINETS WITH INTEGRATED STAINLESS SINK AND FAUCET IN ALL EXAM ROOMS, WOMEN S HEALTH, BLOOD LAB (CLEAN AND DIRTY COUNTERS W/SEPARATION BETWEEN THEM-USE PJ LAYOUT) AND DIRTY ROOM. ALL DRAWERS AND CABINET DOORS SHALL HAVE KEY LOCKS INSTALLED\nCASEWORK COUNTERTOP TO BE CORIAN-USE POUGHKEEPSIE SPEC FOR CABINETS\nRECEPTION AREA COUNTERTOPS TO BE CORIAN\nLOCKERS IN STAFF AREA-USE POUGHKEEPSIE SPEC-LOCKERS.COM- 12 LOCKERS\nElectrical Notes (Power-Lighting-Data-Communication)\nMINIMUM WIRE SIZE SHALL BE 12 GAGE AND CIRCUIT BREAKER SHALL BE 20 AMPS\nLAB AND PODIATRY SHALL HAVE EMERGENCY LIGHT BACKUP\nROOMS WITH NO WINDOWS SHALL HAVE EMERGENCY LIGHTS\nNURSE CALL CALL FOR AID (LOCAL W/STROBE) HARDWIRED CONTROL AT RECEPTION AND LOCAL\nSEPARATE CAT6 RUNS FOR WALL PHONES AND COMPUTERS\nEACH RUN TO EACH ROOM SHALL HAVE A MINIMUM OF 3 CAT6 CABLES-EACH CABLE SHALL BE TERMINATED ON DIFFERENT WALLS OF THE ROOM\nPROVIDE CAT6 SHIELDED CABLE WITH ASSOCIATED SHIELDED CONNECTORS FOR VA PROVIDED WIFI ROUTERS THROUGHOUT THE CLINIC. A MINIMUM OF 12 ROUTERS WILL BE PROVIDED.\nPROVIDE (2) 3 PORT DATA OUTLETS IN EACH OF THE ROOMS\nFOR VISUAL FIELDS 3-PORT JACK (2+1) CAMERA-1 PORT / EQUIPMENT-1 PORT\nFOR CVT ROOM 2-PORT JACK (NETWORK)\nWALL PHONES FOR ALL ROOMS 1 CAT 6E DROP FOR WALL-HUNG PHONE ASK MARCOS FOR # OF PHONES\nSPECIFY DEDICATED OUTLETS (PYXIS, DATA, SHREDDER, STAFF LOUNGE (3-4)) AND INSTALLATION OF OUTLETS AS PER NEC CODE FOR MEDICAL OFFICES, I.E. OUTLET EVERY 6 FEET FROM EACH OTHER.\nPOWER OUTLETS FOR CABLE TV S\nINSTALL SUFFICIENT NUMBER OF DEDICATED OUTLETS (AT LEAST 5) BY KITCHEN COUNTERTOP FOR ALL APPLIANCES\nLIGHT FIXTURES SHALL BE 2 X2 LED WITH T8 LAMPS AND HIGH EFFICIENCY BALLASTS. OCCUPIED SPACES SHALL BE DESIGNED TO 50 FOOT CANDLES (FC) AND NON-OCCUPIED SPACES SHALL BE DESIGNED TO 10 FC MINIMUM. NON-OCCUPIED SPACES SHALL BE CONTROLLED BY AN INFRARED TYPE OCCUPANCY SENSOR AND OCCUPIED SPACES SHALL BE CONTROLLED BY TOGGLE SWITCHES.\nMINIMUM OF (4) LIGHT FIXTURES PER ROOM (2 X 2 ) WITH ENOUGH FOOT CANDLES ESPECIALLY PODIATRY\nLIGHT FIXTURES LOCATED NEAR FRONT AND REAR DOOR SHALL BE HARD WIRED TO A DEDICATED CIRCUIT, ENSURING ENTRY AND EXIT PASSAGE LIGHTING IS ALWAYS ON.\nEMERGENCY EGRESS LIGHTING AND ILLUMINATED EXIT SIGNS SHALL HAVE 90 MINUTES MINIMUM BATTERY BACKUP.\nALL WIRING FOR DATA AND TELECOMMUNICATIONS SHALL BE IN CONDUIT. LEAVE ABOUT 10-12 FEET OF EXCESS CABLES COILED IN THE DATA ROOM.\nEVERY ROOM SHALL HAVE A MINIMUM OF ONE 4-PORT DATA/VOICE RECEPTACLE. EXAM ROOMS, OFFICES, CONFERENCE ROOMS, WAITING AREA AND RECEPTION SHALL HAVE THREE 4-PORT DATA RECEPTACLE. EACH RECEPTACLE SHALL HAVE SIX CAT 6 CABLES AND SHALL BE LOCATED WITHIN 12 FROM 110 VOLT RECEPTACLE. BOTH CABLE ENDS SHALL BE LABELED.\nTHE DATA/PHONE ROOM WALL SURFACES SHALL BE LINED WITH FIRE RETARDANT PLYWOOD EXTENDING FROM 6 A.F.F. TO 8 -6 HIGH AND PAINTED BLACK, ROUTING OF CABLES SHALL BE IN CABLE TRAYS AND LOCATED ABOVE OR ADJACENT TO CORRIDORS AND BE ACCESSIBLE FROM A LADDER PLACED IN THE CORRIDOR FOR FUTURE MAINTENANCE.\nCABLES FOR CABLE TV SHALL BE PROVIDED IN CONDUIT FROM POINT OF ENTRY INTO THE CLINIC TO WAITING AREA AND CONFERENCE ROOMS. 110 VOLT RECEPTACLES SHALL BE PROVIDED TO POWER THE CABLE BOXES.\nCONTRACTOR SHALL ALSO INSTALL CONDUIT FOR ALL DATA AND TELECOMMUNICATION CABLE PULLS FROM THE UTILITY ROOM TO DATA ROOM CLOSET. ALL WIRING SHALL CONFORM TO THE BUILDING CODES LISTED ABOVE.\nINSTALL AND WIRE ALL ELECTRICAL OUTLETS PER VA PROPOSED LAYOUT.\nINSTALL AND WIRE ALL PHONE AND DATA OUTLETS PER VA PROPOSED LAYOUT, ALL WIRING SHALL BE CAT 6. A TRIPLE CONNECTION SHALL BE PULLED TO EACH LOCATION.\nTERMINATE DATA LINE IN ALL ROOMS AND LEAVE A 12 - 15FT NON-TERMINATED CABLE COIL IN THE DATA ROOM. ALL CABLES TO BE LABELED ON BOTH ENDS OF WIRE PULL\nALL OUTLETS SHALL BE HOSPITAL GRADE 20 AMP CIRCUITS UNLESS OTHERWISE SPECIFIED\nLIGHT FIXTURES LOCATED NEAR FRONT AND REAR DOOR SHALL BE HARD WIRED TO A DEDICATED CIRCUIT ENSURING ENTRY AND EXITING PASSAGE LIGHTING IS ALWAYS ON\nSHALL PROVIDE AND INSTALL BATTERY BACKUP (90 MINUTES MINIMUM) EMERGENCY EGRESS LIGHTING\nSHALL PROVIDE AND INSTALL ILLUMINATED EMERGENCY EXIT SIGNS WITH 90 MINUTES BATTERY BACKUP\nLAB AND PODIATRY SHALL HAVE EMERGENCY LIGHT BACKUP\nROOMS WITH NO WINDOWS SHALL HAVE EMERGENCY LIGHTS\nNURSE CALL CALL FOR AID (LOCAL W/STROBE) - HARDWIRED\nPOWER OUTLETS EVERY 6 FEET PER NEC\nKIOSK DATA AND POWER\nHEALTHY VET DESK DATA AND POWER (CONFIRM W/SHATHA)\nEACH RUN TO EACH ROOM SHALL HAVE A MINIMUM OF 3 CAT6 CABLES-EACH CABLE SHALL BE TERMINATED ON DIFFERENT WALLS OF THE ROOM\nPYXIS/EKG DEDICATED CIRCUITS\nSPECIFY DEDICATED OUTLETS FOR DATA, SHREDDER, STAFF LOUNGE (3-4)) AND INSTALLATION OF OUTLETS AS PER NEC CODE FOR MEDICAL OFFICES, I.E. OUTLET EVERY 6 FEET FROM EACH OTHER.\nDATA CLOSET PHONES:\nPROVIDE WIRING IN CONDUIT FOR ALL CABLES FROM BUILDING DEMARCATION ROOM TO THE DATA CLOSET\nFIRE STOP ALL PENETRATIONS IN CEILING WALLS AND FLOORS.\nPROVIDE 2 X 3 - Â¾ PAINTED PLYWOOD ON WALL PROVIDE SMOKE DETECTOR INSIDE DATA CLOSET\nPROVIDE LAYOUT OF EQUIPMENT AND FURNITURE TO PINPOINT LOCATION OF POWER AND DATA OUTLETS\nRACK FOR PATCH PANELS AND NETWORKING EQUIPMENT\nDEDICATED OUTLETS (3) 20AMP\nDEDICATED AC UNIT\nALARM ON THE OUTSID INSTALL HI-TEMP LOCAL ALARM W/FEATURE TO SILENCE AND BYPASS. INSTALL STROBE AND HORN OUTSIDE W/SIGN HI TEMP\nBACKUP THERMOSTATICALLY CONTROLLED EXHAUST FAN W/AUDIO AND VISUAL ALARM IF IT COMES ON AND SILENCE BUTTON\nCAT6 CABLES FOR MINIMUM OF 8 WI-FI ROUTERS LOCATION TO BE DETERMINED BY VA\nCAT6 CABLE DROPS FOR EACH ROOM 2 FOR DATA OUTLET AND 1 FOR WALL PHONE\nALL CAT6 CABLES SHALL BE PLENUM RATED OR IN CONDUIT.\nPlumbing / HVAC Notes\nUNLESS OTHERWISE SPECIFIED, ALL SINKS SHALL HAVE WRIST BLADE CONTROL HANDLES, HOT AND COLD WATER SUPPLY AND PROPER DRAINAGE.\nSINKS LOCATED WITHIN RESTROOMS SHALL BE ADA COMPLIANT. FAUCET HARDWARE SHALL BE ADA COMPLIANT. FOOT PEDALS ARE NOT REQUIRED. ALL TOILETS INSTALLED SHALL BE OF PROPER ADA HEIGHT.\nSINK LOCATED IN THE STAFF ROOM SHALL BE A DOUBLE STAINLESS STEEL SINK WITH KITCHEN FAUCET AND SPRAY HOSE. FOOT PEDALS ARE NOT REQUIRED.\nPLUMBING FIXTURES SHALL BE LOW FLOW TYPE AND THE HOT WATER SYSTEM SHALL BE LOOPED FOR RECIRCULATION. ELECTRONIC FLUSH VALVES AND FAUCETS SHALL BE PROVIDED FOR ALL FIXTURES. EXAM ROOM SINKS SHALL HAVE GOOSENECK SPOUTS AND PEDAL OPERATED FAUCETS.\nPROVIDE HI-RISE TOILETS AND COVERS FOR PIPING.\nPROVIDE CHILLED WATER BOTTLING STATIONS IN WAITING AREA, WITH POWER, COLD WATER SUPPLY AND DRAINAGE.\nPROVIDE FILTRATION AND MAINTENANCE FOR REFRIGERATED WATER BOTTLING STATIONS.\nJANITORIAL CLOSET SHALL HAVE A FLOOR MOUNTED MOP SINK INSTALLED CONNECTED TO DRAINAGE SYSTEM. THERE SHALL BE A WALL MOUNTED JANITORIAL FAUCET INSTALLED WITH HOT AND COLD WATER SERVICE.\nALL ROOMS OF THE SUITE SHALL HAVE HVAC DIFFUSERS AND RETURNS PROPERLY SIZED FOR THE ROOM.\nTHE HVAC SYSTEM SHALL BE DESIGNED TO PROVIDE INDIVIDUALLY CONTROLLED THERMOSTATS EACH WITH ITS OWN VAV FOR ALL OCCUPIED SPACES (EXAM TYPE ROOMS, RECEPTION, WAITING AREA). UNOCCUPIED SPACES (RESTROOMS, STORAGE, JANITOR, SOILED LINEN ROOM) MAY BE GROUPED WITH NO MORE THAN 4 ROOMS ON ANY ONE VAV. SUPPLY, EXHAUST AND RETURN AIR SYSTEMS SHALL BE DUCTED.\nEXHAUST SYSTEM SHALL BE REQUIRED FOR RESTROOMS, WAITING AREA, DATA ROOM AND OTHERS.\nPOSITIVE AND NEGATIVE AIR PRESSURES FOR CLEAN AND DIRTY ROOMS\nAIR CHANGES REQUIREMENT TAB REPORT (TESTING AND BALANCING)\nMAKE PROVISION FOR FRESH OUTDOOR AIR\nPROVIDE (4) SEPARATE ZONES FOR FRONT (RECEPTION AND LOBBY), REAR AND ONE EACH FOR THE 2 INTERIOR CORRIDORS HYDRONIC SYSTEM W/HUMIDIFIER\nPROVIDE Testing and Balancing reports BY CERTIFIED CONTRACTOR\nPROVIDE DUCT LEAKAGE INSPECTION AND REPORT\nCLEAN AND DIRTY ROOMS POSITIVE AND NEGATIVE AIR\nFire Sprinkler and Fire Alarm Notes\nBUILDING SHALL BE FULLY SPRINKLERED AND THE DESIGN MUST BE CERTIFIED BY AN INDEPENDENT NEW YORK STATE LICENSED FIRE PROTECTION ENGINEER AND APPROVED BY THE LOCAL FIRE DEPARTMENT AND THE VA.\nCONTRACTOR SHALL INSTALL FIRE SPRINKLER SYSTEM AS PER THE NFPA 13 AND LIFESAFETY DEVICES.\nTHE FIRE ALARM SYSTEM SHALL COMPLY WITH THE LOCAL FIRE DEPARTMENT AND SHALL BE TIED TO THE HVAC SYSTEM TO SHUT THE UNIT DOWN. BATTERY BACKUP SHALL BE PROVIDED.\nPROVIDE FULLY RECESSED FIRE EXTINGUISHER CABINETS\nPROVIDE SHALL PROVIDE AND INSTALL APPROVED FIRE EXTINGUISHERS IN CABINETS\nALL PENETRATIONS FROM MECHANICAL ROOMS, STORAGES, JANITORIAL AND/OR SUITE TO SUITE SHALL BE PROPERLY FIRE SEALED\nSecurity System Notes\nTHE BURGLAR ALARM SYSTEM SHALL DETECT ENTRY AT EITHER FRONT OR REAR ENTRY/EXIT DOORS. AND ALSO DETECT BROKEN GLASS IN AREAS WHICH ARE RELATIVELY ACCESSIBLE. THE SYSTEM SHALL INTERFACE WITH THE LOCAL POLICE DEPARTMENT AS WELL AS THE VA POLICE DEPARTMENT. ALL SECURITY WIRING SHALL BE IN CONDUIT.\nAN ELECTRONIC PERSONNEL PROTECTION SYSTEM SHALL BE A DURESS-PANIC ALARM TYPE. EMERGENCY BUTTONS SHALL BE LOCATED AT THE RECEPTION DESK. A CCTV SYSTEM WITH AN NVR SHALL BE EMPLOYED TO MONITOR ALL EXTERIOR DOORS AND MAIN LOBBY.\nPROVIDE SECURED MAILBOX\nCONTRACTOR SHALL HAVE A BURGLAR ALARM SYSTEM INSTALLED FOR THE OCCUPIED SPACES\nA. DETECT ENTRY ON EITHER FRONT OR REAR ENTRY/EXIT DOORS\nB. DETECT BROKEN WINDOW ON AREAS WERE RELATIVELY ACCESSIBLE\nPROVIDE INTRUSION, PANIC AND CCTV\nFSL LEVEL 2 CCTV-PANIC-INTRUSION COORDINATE WITH VA VENDOR\nFSL LEVEL 3 - BOLLARDS VA SPEC (4000 LBS)\nTESTING:\nPRIOR TO OCCUPANCY, PROVIDE THE FOLLOWING INSPECTIONS, TESTS AND DETAILED REPORTS. THE INSPECTION AND TESTING AGENCIES SHALL BE AN INDEPENDENT THIRD PARTY AND SHALL BE LICENSED AND CERTIFIED BY NEW YORK STATE. A MINIMUM OF 3 AGENCIES SHALL BE SUBMITTED TO THE VA COR FOR REVIEW AND APPROVAL AND SELECTION OF THE AGENCY.\n1. CERTIFICATE OF OCCUPANCY\n2. DUCT LEAKAGE TEST\n3. TESTING AND BALANCING\n4. AIR QUALITY TESTING\n5. WATER TESTING\n6. FIRE INSPECTION","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24225R0019","place_of_performance":{"zip":"10512","street":"Carmel, NY","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"X1DB"}],"due_at":"2026-01-29T22:00:00Z","due_date":"2026-01-29","closes_at":"2026-01-29T22:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36079","county_name":"Putnam County","city":null,"city_name":null,"country":"USA","state_source":"sam_zip","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-19T02:14:35.653114Z","principal_notice_id":"26036b10c4b845f7a498d3cd79962dcb","description":{"text":"The potential lease space selected must be built out for the VA Medical Center to occupy and open a clinic. The Lessor shall procure an Architect/Engineer (AE) to perform a design build for approximately 6500 Net Usable Square Feet for the potential space to be leased. The Lessor and Architect/Engineer shall ensure that the space will meet or exceed the most stringent of the NYS Building Code, NFPA 101 Life Safety Code, NEC and any local applicable building codes.\nThe AE shall incorporate the VA provided preliminary proposed layout in the design phase. This layout shall be used as the basis-of-design starting point. It is expected that through the design phase meetings with the VA, these will be modified to suit the VA needs.\nProvide labor all new materials, fixtures, tools, equipment and Architect-Engineer (AE) services necessary for design and construction of a fully functional Community based Outpatient Clinic at Carmel, NY.\nThe Lessor shall:\n1. Ensure that the Architect/Engineer (AE) performs a design build of the space per the layout approved by VA.\na. The AE shall provide the 35%, 65% and 100% submission drawings to the VA COR for approval.\nb. AE shall provide submittals of all construction materials to be used within the build out of the space to the VA COR for approval.\n2. The space shall be built out to include but not limited to the following areas. Refer to the space Configuration plan for the list of proposed rooms.\na. Reception Area\ni. Including sliding windows for patient communication both sides of angled windows\nii. Counter space for patients and employees at window\niii. One of the windows shall be at an ADA approved height counter.\nb. Waiting Area to accommodate a minimum of 20 patients and set up for cable TV.\nb. Vestibule area\nc. Staff Room with kitchenette\ni. Including Stainless steel sink and faucet\nii. Base and Wall cabinets\niii. (3) dedicated 20-amp outlets for small appliances\niv. 1 dedicated 20-amp outlet each for refrigerator and Microwave oven.\nd. ADA restrooms\ni. Restrooms shall have mirrors installed above sink\nii. Exhaust fans shall be installed in restrooms that activate with lights\niii. Provide diaper changing station and nurse call system which shall activate an alarm at the reception desk and a strobe light with the words HELP outside the restroom.\ne. 1 Optometry exam room with 2 lighting controls\ni. 2 x 2 Fluorescent light fixtures with toggle switch\nii. High hat light fixtures with dimming capabilities and dimmer switch\nf. 1 Visual Fields room\ni. 2 x 2 Fluorescent light fixtures with toggle switch\nii. High hat light fixtures with dimming capabilities and dimmer switch\ng. Medical and Office supplies Storage Room with shelving\nh. Phlebotomy Lab Suite with Restroom\ni. Conference room\ni. Conference room shall have plumbing roughed in for future sink installations.\nii. Build sheetrock wall enclosing the back side of the mailboxes on existing wall in front conference room.\nj. Medical offices\nk. Data/Phone Room\ni. Install dedicated room air conditioner to cool communication equipment maintaining year-round temperature between 68 - 72 degrees F. Room requires cooling year-round due to sensitive equipment.\nii. Thermostatically controlled Exhaust fan\niii. Shall have a 1-hour fire rated construction rating\niv. Shall have a 1-hour fire rated door with self-closer and self-latching hardware\nl. Hazardous material storage area\nm. Copy Room and Office supplies storage with shelving\nn. Janitorial closet\ni. Closet shall have floor mounted service/mop sink\nii. Shall have a wall mounted janitorial faucet installed\niii. Shall have a 1 hour fire rated construction rating\niv. Shall have a 1-hour fire rated door with self-closer and self-latching hardware\nv. Thermostatically controlled exhaust with manual by-pass switch\no. Medical Exam Rooms\np. Women s health Suites\nq. Dirty room equipped with stand-alone stainless sink with faucets and negative air pressure and shelving\nr. Clean room with shelving and Positive pressure\ns. Wheelchair storage and Coat closet with sliding door\nt. Patient Education and Conference-Video-Telehealth rooms\nu. Touch down / Swing Office room\n3. Provide and install chilled water bottling stations.\nGeneral Notes\nTHE LANDLORD SHALL BE SOLELY RESPONSIBLE FOR THE MANAGEMENT, PROFESSIONAL DESIGN, AND CONSTRUCTION, INCLUDING ALL LABOR, EQUIPMENT, MATERIALS, AND INSPECTION, TO MEET REQUIREMENTS OF THE CONTRACT.\nTHE AE SHALL FURNISH A DESIGN PACKAGE TO INCLUDE PLANS, DETAILS, SECTIONS, ELEVATIONS, SITE-VISITS AND RELATED INFORMATION AS REQUIRED BY THE CONTRACT. THE DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST NFPA 101 LIFE SAFETY CODE, UNIFORM PLUMBING CODE (UPC), NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARD, AMERICAN DISABILITY ACT (ADA) COMPLIANCE, VA SPECIFICATIONS AND STANDARDS, AND LOCAL AND CITY CODES. IN THE EVENT THERE IS CONFLICT BETWEEN ANY OF THE STANDARDS/CODES, THE MORE STRINGENT STANDARD/CODE SHALL APPLY.\nTHE AE SHALL HAVE THE CAPABILITY OF COMPUTER-AIDED-DESIGN (CAD). THE CAD PROGRAM USED BY THE AE IN DESIGNING AND DRAFTING THIS PROJECT SHALL BE ABLE TO INTERFACE WITH THE CAD SYSTEM USED BY VA FACILITIES MANAGEMENT/ENGINEERING SERVICE. IN THE FINAL SUBMISSION, THE AE SHALL SUBMIT BOTH HARD COPY DRAWINGS AND CDS CONTAINING ALL DRAWINGS TO THE VA COR.\nTHE AE SHALL USE MICROSOFT WORD TO PREPARE SPECIFICATIONS. IN THE FINAL SUBMISSION, THE AE SHALL SUBMIT HARDCOPY SPECIFICATIONS TO THE VA. THE VA MASTER SPECIFICATIONS MAY BE OBTAINED FROM VA COR (HTTP://WWW.CFM.VA.GOV/TIL/SPEC.ASP).\nTHE VA SHALL PROVIDE THE AE THE CONCEPTUAL DESIGN, (ATTACHED SKETCH), AND BASED UPON THAT, THE AE SHALL SUBMIT A CONSTRUCTION DOCUMENT DESIGN SUBMISSION. THE AE SHALL SUBMIT (1) FULL SIZE, (1) HALF SIZE, AND (1) ELECTRONIC COPY OF THE DRAWINGS AND ONE (1) SET OF EDITED SPECIFICATIONS. THE AE SHALL SUBMIT (1) FULL SIZE AND (1) ELECTRONIC COPY OF THE FINAL AS-BUILT DRAWINGS. THE CONSTUCTION DRAWINGS SHALL BE SIGNED AND SEALED BY PROFESSIONAL ENGINEER.\nALL SUBMITTALS FOR MATERIAL AND EQUIPMENT SHALL BE APPROVED BY THE VA PRIOR TO INSTALLATION\nFINAL DESIGN AND RECORD DRAWINGS, CAD AND PDF ON DVD\nTHE CONTRACTOR SHALL COMPLY WITH ALL OSHA CONSTRUCTION SAFETY GUIDELINES.\nALL SAFETY VIOLATIONS CITED BY VA SAFETY ENGINEER SHALL BE CORRECTED PRIOR TO\nOCCUPANCY.\nSUPPLY THE VA WITH A COMPLETE CERTIFICATE OF OCCUPANCY UPON ACCEPTANCE OF SPACE.\nAPPLY AND OBTAIN ALL REQUIRED BUILDING PERMITS.\nALL SUBMITTALS FOR MATERIAL AND EQUIPMENT SHALL BE APPROVED BY THE VA PRIOR TO INSTALLATION\nFINAL DESIGN AND RECORD DRAWINGS, CAD AND PDF ON DVD\nPARKING SPACES RESERVED FOR VA SHALL ONLY INDICATE AS RESERVED AND NOT IDENTIFY AS VA OR GOVERNMENT\nArchitectural Notes\nBUILD-OUT SHALL BE COMPLIANT WITH ALL NYS BUILDING AND LOCAL MUNICIPAL CODES, NFPA 101 AND NEC.\nPROVIDE LIFE SAFETY DRAWING FOR REVIEW BY VA LIFE SAFETY ENGINEER\nINCORPORATE A COVERED PATIENT DROP-OFF AREA AS WELL AS HANDICAP ACCESSIBILITY IN THE DESIGN PHASE.\nIT IS ANTICIPATED THAT THE DESIGN WILL PROVIDE A HEALING ENVIRONMENT AND THE COLOR SELECTION AND MATERIAL FINISHES WILL COMPLEMENT THIS. THE AE SHALL COORDINATE THE FINISH COLORS AND MATERIALS WITH THE VA FOR APPROVAL.\nCUT SIDEWALK CURB FOR HANDICAP AND PROVIDE RAMP AND PAINT CURBS YELLOW\nPROVIDE A MINIMUM 30 PARKING SPACES AS CLOSE AS POSSIBLE TO THE CLINIC ENTRANCE. PARKING SPACES RESERVED FOR VA SHALL ONLY INDICATE AS RESERVED AND NOT IDENTIFY AS VA OR GOVERNMENT\nPROVIDE SIGNAGE STREET (LIT PYLON/MARQUEE) AND LIT BUILDING FAÃ‡ADE\nPROVIDE EXTERIOR ON BUILDING FAÃ‡ADE, DOUBLE-SIDED ILLUMINATED SIGNAGE AS PER VA SUPPLIED LOGO.\nPROVIDE DIRECTIONAL SIGNAGE IN CORRIDOR OUTSIDE THE CLINIC SPACE\nINTERIOR ROOM SIGNAGE SHALL HAVE TYPE H (TAKEFORM) DISPLAYING SERVICE AND ROOM NUMBER, EXCEPT FIXED ROOMS SUCH AS RESTROOMS, CONFERENCE ROOMS, RECEPTION, ETC. (CONFIRM IF THESE DON T REQUIRE # S)\nBUILDING AND SUITE ENTRANCE DOORS SHALL BE EQUIPPED WITH FULLY AUTOMATIC DOOR OPERATORS\nSAFETY GLASS FOR SUITE ENTRY DOOR WITH BUSINESS HOURS SIGNAGE\nSTORE FRONT GLASS/WINDOWS IF REQUIRED W/SIGNS HOURS OF OPERATION\nPROVIDE REINFORCEMENT FOR 60 TV AND INSTALL VA PROVIDED TV S\nALL WALL FRAMING SHALL BE 3 5/8 METAL STUDS.\nINSTALL MINIMUM 5/8\" GYPSUM BOARD SHEATHING AT STUDS.\nALL ROOMS CONSTRUCTED SHALL BE BUILT WITH SOUND PROOFING MATERIALS INCLUDING CEILING TILES TO ENSURE PATIENT PRIVACY WITHIN THE ROOM. WALL R-VALUE SHALL BE DESIGNED TO A MINIMUM OF R-21.\nDOORS AND WINDOWS\nALL WINDOWS SHALL HAVE LAMINATED GLASS WITH A U-VALUE BETWEEN 0.28 AND 0.30 AND ALSO INCORPORATE VA SECURITY REQUIREMENTS. THE WINDOWS SHALL HAVE BUILT-IN SHADES.\nALL DOORS SHALL BE OF SOLID CONSTRUCTION. MEDICAL WASTE, JANITOR S CLOSET, DATA/PHONE CLOSET AND MECHANICAL/ELECTRICAL ROOMS SHALL BE SELF-CLOSING AND SELF-LATCHING.\nCORRIDOR DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE WITH CLEARANCE NOT EXCEEDING 1 INCH FROM BOTTOM OF DOOR TO THE FINISHED FLOOR.\nHALLWAY DOORS SHALL HAVE A GLASS WINDOW IN UPPER SECTION TO ALLOW A LINE OF SIGHT WHILE OPENING DOOR.\nDOOR HARDWARE SHALL BE ADA COMPLIANT AND COMPLY WITH NFPA 101 REQUIREMENTS.\nDOOR LOCKSETS SHALL HAVE REPLACEABLE CORES AND MANUFACTURED BY BEST, CORBIN RUSSWIN, OR APPROVED EQUAL. LOCKSETS SHALL BE ADA AND NFPA 101 COMPLIANT.\nLOCKSET FUNCTIONS SHALL BE COORDINATED AND APPROVED BY VA.\nLOCKSETS SHALL BE SINGLE MOTION EGRESS COMPLIANT AND SHALL BE ALL KEYED ALIKE, EXCEPT FOR THE DATA/PHONE ROOM WHICH SHALL COMPLY WITH VA SECURITY GUIDELINES.\nALL HALLWAY DOORS SHALL HAVE A PUSH BUTTON LOCK AND KEY SET INSTALLED WITH A DOOR CLOSER AND SELF LATCHING HARDWARE. DOOR CLOSERS SHALL HAVE A TWO POSITION SETTING TO ALLOW DOOR TO HOLD OPENAND/OR AUTOMATICALLY CLOSE.\nALL DOOR LOCKS SHALL WORK ON A COMMON KEY, EXCEPT FOR THE DATA CLOSET, PYXIS ROOM, AND A FEW OTHER ROOMS. COORDINATE WITH THE VA COR\nSPECIFY PRIVACY INDICATOR LOCKSETS FOR BATHROOMS\nBLINDS SHALL BE APPROVED BY VA\nKEYWAY SHOULD BE BEST (FOR MONTROSE) OR CORBIN RUSSERT (FOR CP)\nCUT EXTRA 25 KEYS FOR CLINIC ENTRY, EXAM ROOMS AND 5 SETS FOR DATA CLOSET AND PYXIS ROOMS\nHALLWAY DOORS SHALL HAVE A GLASS WINDOW IN UPPER SECTION TO ALLOW A LINE OF SIGHT WHILE OPENING DOOR.\nHAZMAT STORAGE, EMS CLOSETS, PHONE/DATA CLOSET AND MECHANICAL/ELECTRICAL ROOMS SHALL HAVE SOLID CORE DOOR WITH SELF-LATCHING AND CLOSING HARDWARE INSTALLED\nALL CORRIDOR DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE, WITH CLEARANCE NOT EXCEEDING 1 INCH FROM BOTTOM OF DOOR\nPERMANENT WALL PARTITIONS (RESTROOMS, JANITOR CLOSET, DATA CLOSET SHALL EXTEND FROM STRUCTURAL SLAB TO STRUCTURAL CEILING SLAB AND SHALL BE FIRE RATED.\nFOR ALL OTHER ROOMS, EXTEND WALLS 8\" MINIMUM ABOVE DROP CEILING HEIGHT.\nALL WALLS SHALL BE COVERED WITH ONE COAT OF PRIMER AND TWO COATS OF LATEX FINISH PAINT. THE COLOR OF THE PAINT IS TO BE APPROVED BY THE VA COR PRIOR TO ANY PAINT BEING APPLIED TO WALLS.\nALL SINGLE OCCUPANCY REST ROOMS SHALL HAVE AN ADA COMPLIANT PUSH BUTTON LOCK AND KEY SET INSTALLED.\nRECEPTION AREA SHALL HAVE WINDOWS INSTALLED ON BOTH SIDES OF \"V\" SHAPED WALLS. WINDOWS SHALL BE A SLIDING WINDOW WITH COUNTERTOP FOR THE RECEPTIONIST AND PATIENT. ONE OF THE WINDOWS SHALL HAVE THE COUNTERTOP AT AN ADA HEIGHT.\nALL OPEN PENETRATIONS FROM STORAGE, MECHANICAL AND SUITE TO SUITE SHALL BE FIRE STOPPED.\nTHE FRONT ENTRANCE DOORWAY(S) SHALL BE SIMILAR TO AN ALUMINUM AND GLASS STOREFRONT WITH HANDICAP ACCESSIBLE AUTOMATIC DOOR OPENERS.\nALL FLOORING SHALL BE SOLID VINYL TILE (SVT). THERE SHALL BE COVE BASE MEETING THE SVT TO THE FINISHED WALL.\nCONTRACTOR SHALL INSTALL DROP CEILING TO A DETERMINED HEIGHT APPROVED BY THE VA COR AND SHALL USE SOUNDPROOF CEILING TILES.\nOPTOMETRY ROOM SHALL BE AT LEAST 16 FEET LONG\nPROVIDE SCHEDULE SHOWING AREAS OF ALL ROOMS AND ALSO ON FLOOR PLAN DRAWING\nPROVIDE SCHEDULE FOR DOOR SIZES, CONSTRUCTION AND FIRE RATING\nPROVIDE SCHEDULE DULE OF FLOORING (REFER TO GOSHEN BUILDOUT) SHOWING TYPE OF FLOORING FOR EACH ROOM AND ASSOCIATED PATTERN\nPROVIDE SCHEDULE FOR PAINT, SHOWING COLOR, TYPE, MANUFACTURER AND STYLE\nPROVIDE SCHEDULE OF ALL AREAS IN SQUARE FOOTAGE, INCLUDING VESTIBULE, WAITING AND ALL OTHER ROOMS WITHIN THE CLINIC SPACE\nDATA ROOM-WALL EXTENDS UP TO DECK-2 SETS OF LOCKSETS-AC-2 X3 FINISHED 1/2' PAINTED PLYWOOD- RACK FOR PATCH PANELS AND SWITCHES-PATCH PANELS\nPROVIDE HANDRAILS ON WALL\nCORRIDORS SHALL BE BETWEEN 44-48\nFURNITURE\nPROVIDE LAYOUT OF EQUIPMENT AND FURNITURE TO PINPOINT LOCATION OF POWER AND DATA OUTLETS\nBACKING SUPPORT SHALL BE REQUIRED FOR ALL FURNITURE AND EQUIPMENT.\nCASEWORK FOR ALL ROOMS EXCEPT DATA CLOSET, MR, CONFERENCE ROOM, TOUCHDOWN ROOM, STORAGE ROOM, CLEAN ROOM, V-TEL ROOM\nCASEWORK SHALL HAVE BASE AND WALL CABINETS WITH INTEGRATED STAINLESS SINK AND FAUCET IN ALL EXAM ROOMS, WOMEN S HEALTH, BLOOD LAB (CLEAN AND DIRTY COUNTERS W/SEPARATION BETWEEN THEM-USE PJ LAYOUT) AND DIRTY ROOM. ALL DRAWERS AND CABINET DOORS SHALL HAVE KEY LOCKS INSTALLED\nCASEWORK COUNTERTOP TO BE CORIAN-USE POUGHKEEPSIE SPEC FOR CABINETS\nRECEPTION AREA COUNTERTOPS TO BE CORIAN\nLOCKERS IN STAFF AREA-USE POUGHKEEPSIE SPEC-LOCKERS.COM- 12 LOCKERS\nElectrical Notes (Power-Lighting-Data-Communication)\nMINIMUM WIRE SIZE SHALL BE 12 GAGE AND CIRCUIT BREAKER SHALL BE 20 AMPS\nLAB AND PODIATRY SHALL HAVE EMERGENCY LIGHT BACKUP\nROOMS WITH NO WINDOWS SHALL HAVE EMERGENCY LIGHTS\nNURSE CALL CALL FOR AID (LOCAL W/STROBE) HARDWIRED CONTROL AT RECEPTION AND LOCAL\nSEPARATE CAT6 RUNS FOR WALL PHONES AND COMPUTERS\nEACH RUN TO EACH ROOM SHALL HAVE A MINIMUM OF 3 CAT6 CABLES-EACH CABLE SHALL BE TERMINATED ON DIFFERENT WALLS OF THE ROOM\nPROVIDE CAT6 SHIELDED CABLE WITH ASSOCIATED SHIELDED CONNECTORS FOR VA PROVIDED WIFI ROUTERS THROUGHOUT THE CLINIC. A MINIMUM OF 12 ROUTERS WILL BE PROVIDED.\nPROVIDE (2) 3 PORT DATA OUTLETS IN EACH OF THE ROOMS\nFOR VISUAL FIELDS 3-PORT JACK (2+1) CAMERA-1 PORT / EQUIPMENT-1 PORT\nFOR CVT ROOM 2-PORT JACK (NETWORK)\nWALL PHONES FOR ALL ROOMS 1 CAT 6E DROP FOR WALL-HUNG PHONE ASK MARCOS FOR # OF PHONES\nSPECIFY DEDICATED OUTLETS (PYXIS, DATA, SHREDDER, STAFF LOUNGE (3-4)) AND INSTALLATION OF OUTLETS AS PER NEC CODE FOR MEDICAL OFFICES, I.E. OUTLET EVERY 6 FEET FROM EACH OTHER.\nPOWER OUTLETS FOR CABLE TV S\nINSTALL SUFFICIENT NUMBER OF DEDICATED OUTLETS (AT LEAST 5) BY KITCHEN COUNTERTOP FOR ALL APPLIANCES\nLIGHT FIXTURES SHALL BE 2 X2 LED WITH T8 LAMPS AND HIGH EFFICIENCY BALLASTS. OCCUPIED SPACES SHALL BE DESIGNED TO 50 FOOT CANDLES (FC) AND NON-OCCUPIED SPACES SHALL BE DESIGNED TO 10 FC MINIMUM. NON-OCCUPIED SPACES SHALL BE CONTROLLED BY AN INFRARED TYPE OCCUPANCY SENSOR AND OCCUPIED SPACES SHALL BE CONTROLLED BY TOGGLE SWITCHES.\nMINIMUM OF (4) LIGHT FIXTURES PER ROOM (2 X 2 ) WITH ENOUGH FOOT CANDLES ESPECIALLY PODIATRY\nLIGHT FIXTURES LOCATED NEAR FRONT AND REAR DOOR SHALL BE HARD WIRED TO A DEDICATED CIRCUIT, ENSURING ENTRY AND EXIT PASSAGE LIGHTING IS ALWAYS ON.\nEMERGENCY EGRESS LIGHTING AND ILLUMINATED EXIT SIGNS SHALL HAVE 90 MINUTES MINIMUM BATTERY BACKUP.\nALL WIRING FOR DATA AND TELECOMMUNICATIONS SHALL BE IN CONDUIT. LEAVE ABOUT 10-12 FEET OF EXCESS CABLES COILED IN THE DATA ROOM.\nEVERY ROOM SHALL HAVE A MINIMUM OF ONE 4-PORT DATA/VOICE RECEPTACLE. EXAM ROOMS, OFFICES, CONFERENCE ROOMS, WAITING AREA AND RECEPTION SHALL HAVE THREE 4-PORT DATA RECEPTACLE. EACH RECEPTACLE SHALL HAVE SIX CAT 6 CABLES AND SHALL BE LOCATED WITHIN 12 FROM 110 VOLT RECEPTACLE. BOTH CABLE ENDS SHALL BE LABELED.\nTHE DATA/PHONE ROOM WALL SURFACES SHALL BE LINED WITH FIRE RETARDANT PLYWOOD EXTENDING FROM 6 A.F.F. TO 8 -6 HIGH AND PAINTED BLACK, ROUTING OF CABLES SHALL BE IN CABLE TRAYS AND LOCATED ABOVE OR ADJACENT TO CORRIDORS AND BE ACCESSIBLE FROM A LADDER PLACED IN THE CORRIDOR FOR FUTURE MAINTENANCE.\nCABLES FOR CABLE TV SHALL BE PROVIDED IN CONDUIT FROM POINT OF ENTRY INTO THE CLINIC TO WAITING AREA AND CONFERENCE ROOMS. 110 VOLT RECEPTACLES SHALL BE PROVIDED TO POWER THE CABLE BOXES.\nCONTRACTOR SHALL ALSO INSTALL CONDUIT FOR ALL DATA AND TELECOMMUNICATION CABLE PULLS FROM THE UTILITY ROOM TO DATA ROOM CLOSET. ALL WIRING SHALL CONFORM TO THE BUILDING CODES LISTED ABOVE.\nINSTALL AND WIRE ALL ELECTRICAL OUTLETS PER VA PROPOSED LAYOUT.\nINSTALL AND WIRE ALL PHONE AND DATA OUTLETS PER VA PROPOSED LAYOUT, ALL WIRING SHALL BE CAT 6. A TRIPLE CONNECTION SHALL BE PULLED TO EACH LOCATION.\nTERMINATE DATA LINE IN ALL ROOMS AND LEAVE A 12 - 15FT NON-TERMINATED CABLE COIL IN THE DATA ROOM. ALL CABLES TO BE LABELED ON BOTH ENDS OF WIRE PULL\nALL OUTLETS SHALL BE HOSPITAL GRADE 20 AMP CIRCUITS UNLESS OTHERWISE SPECIFIED\nLIGHT FIXTURES LOCATED NEAR FRONT AND REAR DOOR SHALL BE HARD WIRED TO A DEDICATED CIRCUIT ENSURING ENTRY AND EXITING PASSAGE LIGHTING IS ALWAYS ON\nSHALL PROVIDE AND INSTALL BATTERY BACKUP (90 MINUTES MINIMUM) EMERGENCY EGRESS LIGHTING\nSHALL PROVIDE AND INSTALL ILLUMINATED EMERGENCY EXIT SIGNS WITH 90 MINUTES BATTERY BACKUP\nLAB AND PODIATRY SHALL HAVE EMERGENCY LIGHT BACKUP\nROOMS WITH NO WINDOWS SHALL HAVE EMERGENCY LIGHTS\nNURSE CALL CALL FOR AID (LOCAL W/STROBE) - HARDWIRED\nPOWER OUTLETS EVERY 6 FEET PER NEC\nKIOSK DATA AND POWER\nHEALTHY VET DESK DATA AND POWER (CONFIRM W/SHATHA)\nEACH RUN TO EACH ROOM SHALL HAVE A MINIMUM OF 3 CAT6 CABLES-EACH CABLE SHALL BE TERMINATED ON DIFFERENT WALLS OF THE ROOM\nPYXIS/EKG DEDICATED CIRCUITS\nSPECIFY DEDICATED OUTLETS FOR DATA, SHREDDER, STAFF LOUNGE (3-4)) AND INSTALLATION OF OUTLETS AS PER NEC CODE FOR MEDICAL OFFICES, I.E. OUTLET EVERY 6 FEET FROM EACH OTHER.\nDATA CLOSET PHONES:\nPROVIDE WIRING IN CONDUIT FOR ALL CABLES FROM BUILDING DEMARCATION ROOM TO THE DATA CLOSET\nFIRE STOP ALL PENETRATIONS IN CEILING WALLS AND FLOORS.\nPROVIDE 2 X 3 - Â¾ PAINTED PLYWOOD ON WALL PROVIDE SMOKE DETECTOR INSIDE DATA CLOSET\nPROVIDE LAYOUT OF EQUIPMENT AND FURNITURE TO PINPOINT LOCATION OF POWER AND DATA OUTLETS\nRACK FOR PATCH PANELS AND NETWORKING EQUIPMENT\nDEDICATED OUTLETS (3) 20AMP\nDEDICATED AC UNIT\nALARM ON THE OUTSID INSTALL HI-TEMP LOCAL ALARM W/FEATURE TO SILENCE AND BYPASS. INSTALL STROBE AND HORN OUTSIDE W/SIGN HI TEMP\nBACKUP THERMOSTATICALLY CONTROLLED EXHAUST FAN W/AUDIO AND VISUAL ALARM IF IT COMES ON AND SILENCE BUTTON\nCAT6 CABLES FOR MINIMUM OF 8 WI-FI ROUTERS LOCATION TO BE DETERMINED BY VA\nCAT6 CABLE DROPS FOR EACH ROOM 2 FOR DATA OUTLET AND 1 FOR WALL PHONE\nALL CAT6 CABLES SHALL BE PLENUM RATED OR IN CONDUIT.\nPlumbing / HVAC Notes\nUNLESS OTHERWISE SPECIFIED, ALL SINKS SHALL HAVE WRIST BLADE CONTROL HANDLES, HOT AND COLD WATER SUPPLY AND PROPER DRAINAGE.\nSINKS LOCATED WITHIN RESTROOMS SHALL BE ADA COMPLIANT. FAUCET HARDWARE SHALL BE ADA COMPLIANT. FOOT PEDALS ARE NOT REQUIRED. ALL TOILETS INSTALLED SHALL BE OF PROPER ADA HEIGHT.\nSINK LOCATED IN THE STAFF ROOM SHALL BE A DOUBLE STAINLESS STEEL SINK WITH KITCHEN FAUCET AND SPRAY HOSE. FOOT PEDALS ARE NOT REQUIRED.\nPLUMBING FIXTURES SHALL BE LOW FLOW TYPE AND THE HOT WATER SYSTEM SHALL BE LOOPED FOR RECIRCULATION. ELECTRONIC FLUSH VALVES AND FAUCETS SHALL BE PROVIDED FOR ALL FIXTURES. EXAM ROOM SINKS SHALL HAVE GOOSENECK SPOUTS AND PEDAL OPERATED FAUCETS.\nPROVIDE HI-RISE TOILETS AND COVERS FOR PIPING.\nPROVIDE CHILLED WATER BOTTLING STATIONS IN WAITING AREA, WITH POWER, COLD WATER SUPPLY AND DRAINAGE.\nPROVIDE FILTRATION AND MAINTENANCE FOR REFRIGERATED WATER BOTTLING STATIONS.\nJANITORIAL CLOSET SHALL HAVE A FLOOR MOUNTED MOP SINK INSTALLED CONNECTED TO DRAINAGE SYSTEM. THERE SHALL BE A WALL MOUNTED JANITORIAL FAUCET INSTALLED WITH HOT AND COLD WATER SERVICE.\nALL ROOMS OF THE SUITE SHALL HAVE HVAC DIFFUSERS AND RETURNS PROPERLY SIZED FOR THE ROOM.\nTHE HVAC SYSTEM SHALL BE DESIGNED TO PROVIDE INDIVIDUALLY CONTROLLED THERMOSTATS EACH WITH ITS OWN VAV FOR ALL OCCUPIED SPACES (EXAM TYPE ROOMS, RECEPTION, WAITING AREA). UNOCCUPIED SPACES (RESTROOMS, STORAGE, JANITOR, SOILED LINEN ROOM) MAY BE GROUPED WITH NO MORE THAN 4 ROOMS ON ANY ONE VAV. SUPPLY, EXHAUST AND RETURN AIR SYSTEMS SHALL BE DUCTED.\nEXHAUST SYSTEM SHALL BE REQUIRED FOR RESTROOMS, WAITING AREA, DATA ROOM AND OTHERS.\nPOSITIVE AND NEGATIVE AIR PRESSURES FOR CLEAN AND DIRTY ROOMS\nAIR CHANGES REQUIREMENT TAB REPORT (TESTING AND BALANCING)\nMAKE PROVISION FOR FRESH OUTDOOR AIR\nPROVIDE (4) SEPARATE ZONES FOR FRONT (RECEPTION AND LOBBY), REAR AND ONE EACH FOR THE 2 INTERIOR CORRIDORS HYDRONIC SYSTEM W/HUMIDIFIER\nPROVIDE Testing and Balancing reports BY CERTIFIED CONTRACTOR\nPROVIDE DUCT LEAKAGE INSPECTION AND REPORT\nCLEAN AND DIRTY ROOMS POSITIVE AND NEGATIVE AIR\nFire Sprinkler and Fire Alarm Notes\nBUILDING SHALL BE FULLY SPRINKLERED AND THE DESIGN MUST BE CERTIFIED BY AN INDEPENDENT NEW YORK STATE LICENSED FIRE PROTECTION ENGINEER AND APPROVED BY THE LOCAL FIRE DEPARTMENT AND THE VA.\nCONTRACTOR SHALL INSTALL FIRE SPRINKLER SYSTEM AS PER THE NFPA 13 AND LIFESAFETY DEVICES.\nTHE FIRE ALARM SYSTEM SHALL COMPLY WITH THE LOCAL FIRE DEPARTMENT AND SHALL BE TIED TO THE HVAC SYSTEM TO SHUT THE UNIT DOWN. BATTERY BACKUP SHALL BE PROVIDED.\nPROVIDE FULLY RECESSED FIRE EXTINGUISHER CABINETS\nPROVIDE SHALL PROVIDE AND INSTALL APPROVED FIRE EXTINGUISHERS IN CABINETS\nALL PENETRATIONS FROM MECHANICAL ROOMS, STORAGES, JANITORIAL AND/OR SUITE TO SUITE SHALL BE PROPERLY FIRE SEALED\nSecurity System Notes\nTHE BURGLAR ALARM SYSTEM SHALL DETECT ENTRY AT EITHER FRONT OR REAR ENTRY/EXIT DOORS. AND ALSO DETECT BROKEN GLASS IN AREAS WHICH ARE RELATIVELY ACCESSIBLE. THE SYSTEM SHALL INTERFACE WITH THE LOCAL POLICE DEPARTMENT AS WELL AS THE VA POLICE DEPARTMENT. ALL SECURITY WIRING SHALL BE IN CONDUIT.\nAN ELECTRONIC PERSONNEL PROTECTION SYSTEM SHALL BE A DURESS-PANIC ALARM TYPE. EMERGENCY BUTTONS SHALL BE LOCATED AT THE RECEPTION DESK. A CCTV SYSTEM WITH AN NVR SHALL BE EMPLOYED TO MONITOR ALL EXTERIOR DOORS AND MAIN LOBBY.\nPROVIDE SECURED MAILBOX\nCONTRACTOR SHALL HAVE A BURGLAR ALARM SYSTEM INSTALLED FOR THE OCCUPIED SPACES\nA. DETECT ENTRY ON EITHER FRONT OR REAR ENTRY/EXIT DOORS\nB. DETECT BROKEN WINDOW ON AREAS WERE RELATIVELY ACCESSIBLE\nPROVIDE INTRUSION, PANIC AND CCTV\nFSL LEVEL 2 CCTV-PANIC-INTRUSION COORDINATE WITH VA VENDOR\nFSL LEVEL 3 - BOLLARDS VA SPEC (4000 LBS)\nTESTING:\nPRIOR TO OCCUPANCY, PROVIDE THE FOLLOWING INSPECTIONS, TESTS AND DETAILED REPORTS. THE INSPECTION AND TESTING AGENCIES SHALL BE AN INDEPENDENT THIRD PARTY AND SHALL BE LICENSED AND CERTIFIED BY NEW YORK STATE. A MINIMUM OF 3 AGENCIES SHALL BE SUBMITTED TO THE VA COR FOR REVIEW AND APPROVAL AND SELECTION OF THE AGENCY.\n1. CERTIFICATE OF OCCUPANCY\n2. DUCT LEAKAGE TEST\n3. TESTING AND BALANCING\n4. AIR QUALITY TESTING\n5. WATER TESTING\n6. FIRE INSPECTION","html":"The potential lease space selected must be built out for the VA Medical Center to occupy and open a clinic. The Lessor shall procure an Architect/Engineer (AE) to perform a design build for approximately 6500 Net Usable Square Feet for the potential space to be leased. The Lessor and Architect/Engineer shall ensure that the space will meet or exceed the most stringent of the NYS Building Code, NFPA 101 Life Safety Code, NEC and any local applicable building codes.\nThe AE shall incorporate the VA provided preliminary proposed layout in the design phase. This layout shall be used as the basis-of-design starting point. It is expected that through the design phase meetings with the VA, these will be modified to suit the VA needs.\nProvide labor all new materials, fixtures, tools, equipment and Architect-Engineer (AE) services necessary for design and construction of a fully functional Community based Outpatient Clinic at Carmel, NY.\nThe Lessor shall:\n1. Ensure that the Architect/Engineer (AE) performs a design build of the space per the layout approved by VA.\na. The AE shall provide the 35%, 65% and 100% submission drawings to the VA COR for approval.\nb. AE shall provide submittals of all construction materials to be used within the build out of the space to the VA COR for approval.\n2. The space shall be built out to include but not limited to the following areas. Refer to the space Configuration plan for the list of proposed rooms.\na. Reception Area\ni. Including sliding windows for patient communication both sides of angled windows\nii. Counter space for patients and employees at window\niii. One of the windows shall be at an ADA approved height counter.\nb. Waiting Area to accommodate a minimum of 20 patients and set up for cable TV.\nb. Vestibule area\nc. Staff Room with kitchenette\ni. Including Stainless steel sink and faucet\nii. Base and Wall cabinets\niii. (3) dedicated 20-amp outlets for small appliances\niv. 1 dedicated 20-amp outlet each for refrigerator and Microwave oven.\nd. ADA restrooms\ni. Restrooms shall have mirrors installed above sink\nii. Exhaust fans shall be installed in restrooms that activate with lights\niii. Provide diaper changing station and nurse call system which shall activate an alarm at the reception desk and a strobe light with the words  HELP  outside the restroom.\ne. 1 Optometry exam room with 2 lighting controls\ni. 2  x 2  Fluorescent light fixtures with toggle switch\nii. High hat light fixtures with dimming capabilities and dimmer switch\nf. 1 Visual Fields room\ni. 2  x 2  Fluorescent light fixtures with toggle switch\nii. High hat light fixtures with dimming capabilities and dimmer switch\ng. Medical and Office supplies Storage Room with shelving\nh. Phlebotomy Lab Suite with Restroom\ni. Conference room\ni. Conference room shall have plumbing roughed in for future sink installations.\nii. Build sheetrock wall enclosing the back side of the mailboxes on existing wall in front conference room.\nj. Medical offices\nk. Data/Phone Room\ni. Install dedicated room air conditioner to cool communication equipment maintaining year-round temperature between 68 - 72 degrees F. Room requires cooling year-round due to sensitive equipment.\nii. Thermostatically controlled Exhaust fan\niii. Shall have a 1-hour fire rated construction rating\niv. Shall have a 1-hour fire rated door with self-closer and self-latching hardware\nl. Hazardous material storage area\nm. Copy Room and Office supplies storage with shelving\nn. Janitorial closet\ni. Closet shall have floor mounted service/mop sink\nii. Shall have a wall mounted janitorial faucet installed\niii. Shall have a 1 hour fire rated construction rating\niv. Shall have a 1-hour fire rated door with self-closer and self-latching hardware\nv. Thermostatically controlled exhaust with manual by-pass switch\no. Medical Exam Rooms\np. Women s health Suites\nq. Dirty room equipped with stand-alone stainless sink with faucets and negative air pressure and shelving\nr. Clean room with shelving and Positive pressure\ns. Wheelchair storage and Coat closet with sliding door\nt. Patient Education and Conference-Video-Telehealth rooms\nu. Touch down / Swing Office room\n3. Provide and install chilled water bottling stations.\nGeneral Notes\nTHE LANDLORD SHALL BE SOLELY RESPONSIBLE FOR THE MANAGEMENT, PROFESSIONAL DESIGN, AND CONSTRUCTION, INCLUDING ALL LABOR, EQUIPMENT, MATERIALS, AND INSPECTION, TO MEET REQUIREMENTS OF THE CONTRACT.\nTHE AE SHALL FURNISH A DESIGN PACKAGE TO INCLUDE PLANS, DETAILS, SECTIONS, ELEVATIONS, SITE-VISITS AND RELATED INFORMATION AS REQUIRED BY THE CONTRACT. THE DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST NFPA 101 LIFE SAFETY CODE, UNIFORM PLUMBING CODE (UPC), NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARD, AMERICAN DISABILITY ACT (ADA) COMPLIANCE, VA SPECIFICATIONS AND STANDARDS, AND LOCAL AND CITY CODES. IN THE EVENT THERE IS CONFLICT BETWEEN ANY OF THE STANDARDS/CODES, THE MORE STRINGENT STANDARD/CODE SHALL APPLY.\nTHE AE SHALL HAVE THE CAPABILITY OF COMPUTER-AIDED-DESIGN (CAD). THE CAD PROGRAM USED BY THE AE IN DESIGNING AND DRAFTING THIS PROJECT SHALL BE ABLE TO INTERFACE WITH THE CAD SYSTEM USED BY VA FACILITIES MANAGEMENT/ENGINEERING SERVICE. IN THE FINAL SUBMISSION, THE AE SHALL SUBMIT BOTH HARD COPY DRAWINGS AND CDS CONTAINING ALL DRAWINGS TO THE VA COR.\nTHE AE SHALL USE  MICROSOFT WORD  TO PREPARE SPECIFICATIONS. IN THE FINAL SUBMISSION, THE AE SHALL SUBMIT HARDCOPY SPECIFICATIONS TO THE VA. THE VA MASTER SPECIFICATIONS MAY BE OBTAINED FROM VA COR (HTTP://WWW.CFM.VA.GOV/TIL/SPEC.ASP).\nTHE VA SHALL PROVIDE THE AE THE CONCEPTUAL DESIGN, (ATTACHED SKETCH), AND BASED UPON THAT, THE AE SHALL SUBMIT A CONSTRUCTION DOCUMENT DESIGN SUBMISSION. THE AE SHALL SUBMIT (1) FULL SIZE, (1) HALF SIZE, AND (1) ELECTRONIC COPY OF THE DRAWINGS AND ONE (1) SET OF EDITED SPECIFICATIONS. THE AE SHALL SUBMIT (1) FULL SIZE AND (1) ELECTRONIC COPY OF THE FINAL AS-BUILT DRAWINGS. THE CONSTUCTION DRAWINGS SHALL BE SIGNED AND SEALED BY PROFESSIONAL ENGINEER.\nALL SUBMITTALS FOR MATERIAL AND EQUIPMENT SHALL BE APPROVED BY THE VA PRIOR TO INSTALLATION\nFINAL DESIGN AND RECORD DRAWINGS, CAD AND PDF ON DVD\nTHE CONTRACTOR SHALL COMPLY WITH ALL OSHA CONSTRUCTION SAFETY GUIDELINES.\nALL SAFETY VIOLATIONS CITED BY VA SAFETY ENGINEER SHALL BE CORRECTED PRIOR TO\nOCCUPANCY.\nSUPPLY THE VA WITH A COMPLETE CERTIFICATE OF OCCUPANCY UPON ACCEPTANCE OF SPACE.\n  APPLY AND OBTAIN ALL REQUIRED BUILDING PERMITS.\n  ALL SUBMITTALS FOR MATERIAL AND EQUIPMENT SHALL BE APPROVED BY THE VA PRIOR TO INSTALLATION\n  FINAL DESIGN AND RECORD DRAWINGS, CAD AND PDF ON DVD\n  PARKING SPACES RESERVED FOR VA SHALL ONLY INDICATE AS  RESERVED  AND NOT IDENTIFY AS VA OR GOVERNMENT\nArchitectural Notes\nBUILD-OUT SHALL BE COMPLIANT WITH ALL NYS BUILDING AND LOCAL MUNICIPAL CODES, NFPA 101 AND NEC.\nPROVIDE LIFE SAFETY DRAWING FOR REVIEW BY VA LIFE SAFETY ENGINEER\nINCORPORATE A COVERED PATIENT DROP-OFF AREA AS WELL AS HANDICAP ACCESSIBILITY IN THE DESIGN PHASE.\nIT IS ANTICIPATED THAT THE DESIGN WILL PROVIDE A  HEALING  ENVIRONMENT AND THE COLOR SELECTION AND MATERIAL FINISHES WILL COMPLEMENT THIS. THE AE SHALL COORDINATE THE FINISH COLORS AND MATERIALS WITH THE VA FOR APPROVAL.\nCUT SIDEWALK CURB FOR HANDICAP AND PROVIDE RAMP AND PAINT CURBS YELLOW\nPROVIDE A MINIMUM 30 PARKING SPACES AS CLOSE AS POSSIBLE TO THE CLINIC ENTRANCE. PARKING SPACES RESERVED FOR VA SHALL ONLY INDICATE AS  RESERVED  AND NOT IDENTIFY AS VA OR GOVERNMENT\nPROVIDE SIGNAGE   STREET (LIT PYLON/MARQUEE) AND LIT BUILDING FAÃ‡ADE\nPROVIDE EXTERIOR ON BUILDING FAÃ‡ADE, DOUBLE-SIDED ILLUMINATED SIGNAGE AS PER VA SUPPLIED LOGO.\nPROVIDE DIRECTIONAL SIGNAGE IN CORRIDOR OUTSIDE THE CLINIC SPACE\nINTERIOR ROOM SIGNAGE SHALL HAVE TYPE H (TAKEFORM) DISPLAYING SERVICE AND ROOM NUMBER, EXCEPT FIXED ROOMS SUCH AS RESTROOMS, CONFERENCE ROOMS, RECEPTION, ETC. (CONFIRM IF THESE DON T REQUIRE # S)\nBUILDING AND SUITE ENTRANCE DOORS SHALL BE EQUIPPED WITH FULLY AUTOMATIC DOOR OPERATORS\nSAFETY GLASS FOR SUITE ENTRY DOOR WITH BUSINESS HOURS SIGNAGE\nSTORE FRONT GLASS/WINDOWS IF REQUIRED W/SIGNS   HOURS OF OPERATION\nPROVIDE REINFORCEMENT FOR 60  TV AND INSTALL VA PROVIDED TV S\nALL WALL FRAMING SHALL BE 3 5/8  METAL STUDS.\nINSTALL MINIMUM 5/8\" GYPSUM BOARD SHEATHING AT STUDS.\nALL ROOMS CONSTRUCTED SHALL BE BUILT WITH SOUND PROOFING MATERIALS INCLUDING CEILING TILES TO ENSURE PATIENT PRIVACY WITHIN THE ROOM. WALL R-VALUE SHALL BE DESIGNED TO A MINIMUM OF R-21.\nDOORS AND WINDOWS\nALL WINDOWS SHALL HAVE LAMINATED GLASS WITH A U-VALUE BETWEEN 0.28 AND 0.30 AND ALSO INCORPORATE VA SECURITY REQUIREMENTS. THE WINDOWS SHALL HAVE BUILT-IN SHADES.\nALL DOORS SHALL BE OF SOLID CONSTRUCTION. MEDICAL WASTE, JANITOR S CLOSET, DATA/PHONE CLOSET AND MECHANICAL/ELECTRICAL ROOMS SHALL BE SELF-CLOSING AND SELF-LATCHING.\nCORRIDOR DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE WITH CLEARANCE NOT EXCEEDING 1 INCH FROM BOTTOM OF DOOR TO THE FINISHED FLOOR.\nHALLWAY DOORS SHALL HAVE A GLASS WINDOW IN UPPER SECTION TO ALLOW A LINE OF SIGHT WHILE OPENING DOOR.\nDOOR HARDWARE SHALL BE ADA COMPLIANT AND COMPLY WITH NFPA 101 REQUIREMENTS.\nDOOR LOCKSETS SHALL HAVE REPLACEABLE CORES AND MANUFACTURED BY  BEST, CORBIN RUSSWIN, OR APPROVED EQUAL. LOCKSETS SHALL BE ADA AND NFPA 101 COMPLIANT.\nLOCKSET FUNCTIONS SHALL BE COORDINATED AND APPROVED BY VA.\nLOCKSETS SHALL BE SINGLE MOTION EGRESS COMPLIANT AND SHALL BE ALL KEYED ALIKE, EXCEPT FOR THE DATA/PHONE ROOM WHICH SHALL COMPLY WITH VA SECURITY GUIDELINES.\nALL HALLWAY DOORS SHALL HAVE A PUSH BUTTON LOCK AND KEY SET INSTALLED WITH A DOOR CLOSER AND SELF LATCHING HARDWARE. DOOR CLOSERS SHALL HAVE A TWO POSITION SETTING TO ALLOW DOOR TO HOLD OPENAND/OR AUTOMATICALLY CLOSE.\nALL DOOR LOCKS SHALL WORK ON A COMMON KEY, EXCEPT FOR THE DATA CLOSET, PYXIS ROOM, AND A FEW OTHER ROOMS. COORDINATE WITH THE VA COR\nSPECIFY PRIVACY INDICATOR LOCKSETS FOR BATHROOMS\nBLINDS SHALL BE APPROVED BY VA\nKEYWAY SHOULD BE BEST (FOR MONTROSE) OR CORBIN RUSSERT (FOR CP)\nCUT EXTRA 25 KEYS FOR CLINIC ENTRY, EXAM ROOMS AND 5 SETS FOR DATA CLOSET AND PYXIS ROOMS\nHALLWAY DOORS SHALL HAVE A GLASS WINDOW IN UPPER SECTION TO ALLOW A LINE OF SIGHT WHILE OPENING DOOR.\nHAZMAT STORAGE, EMS CLOSETS, PHONE/DATA CLOSET AND MECHANICAL/ELECTRICAL ROOMS SHALL HAVE SOLID CORE DOOR WITH SELF-LATCHING AND CLOSING HARDWARE INSTALLED\nALL CORRIDOR DOORS SHALL BE CONSTRUCTED TO RESIST THE PASSAGE OF SMOKE, WITH CLEARANCE NOT EXCEEDING 1 INCH FROM BOTTOM OF DOOR\nPERMANENT WALL PARTITIONS (RESTROOMS, JANITOR CLOSET, DATA CLOSET SHALL EXTEND FROM STRUCTURAL SLAB TO STRUCTURAL CEILING SLAB AND SHALL BE FIRE RATED.\nFOR ALL OTHER ROOMS, EXTEND WALLS 8\" MINIMUM ABOVE DROP CEILING HEIGHT.\nALL WALLS SHALL BE COVERED WITH ONE COAT OF PRIMER AND TWO COATS OF LATEX FINISH PAINT. THE COLOR OF THE PAINT IS TO BE APPROVED BY THE VA COR PRIOR TO ANY PAINT BEING APPLIED TO WALLS.\nALL SINGLE OCCUPANCY REST ROOMS SHALL HAVE AN ADA COMPLIANT PUSH BUTTON LOCK AND KEY SET INSTALLED.\nRECEPTION AREA SHALL HAVE WINDOWS INSTALLED ON BOTH SIDES OF \"V\" SHAPED WALLS. WINDOWS SHALL BE A SLIDING WINDOW WITH COUNTERTOP FOR THE RECEPTIONIST AND PATIENT. ONE OF THE WINDOWS SHALL HAVE THE COUNTERTOP AT AN ADA HEIGHT.\nALL OPEN PENETRATIONS FROM STORAGE, MECHANICAL AND SUITE TO SUITE SHALL BE FIRE STOPPED.\nTHE FRONT ENTRANCE DOORWAY(S) SHALL BE SIMILAR TO AN ALUMINUM AND GLASS STOREFRONT WITH HANDICAP ACCESSIBLE AUTOMATIC DOOR OPENERS.\nALL FLOORING SHALL BE SOLID VINYL TILE (SVT). THERE SHALL BE COVE BASE MEETING THE SVT TO THE FINISHED WALL.\nCONTRACTOR SHALL INSTALL DROP CEILING TO A DETERMINED HEIGHT APPROVED BY THE VA COR AND SHALL USE SOUNDPROOF CEILING TILES.\nOPTOMETRY ROOM SHALL BE AT LEAST 16 FEET LONG\nPROVIDE SCHEDULE SHOWING AREAS OF ALL ROOMS AND ALSO ON FLOOR PLAN DRAWING\nPROVIDE SCHEDULE FOR DOOR SIZES, CONSTRUCTION AND FIRE RATING\nPROVIDE SCHEDULE DULE OF FLOORING (REFER TO GOSHEN BUILDOUT) SHOWING TYPE OF FLOORING FOR EACH ROOM AND ASSOCIATED PATTERN\nPROVIDE SCHEDULE FOR PAINT, SHOWING COLOR, TYPE, MANUFACTURER AND STYLE\nPROVIDE SCHEDULE OF ALL AREAS IN SQUARE FOOTAGE, INCLUDING VESTIBULE, WAITING AND ALL OTHER ROOMS WITHIN THE CLINIC SPACE\nDATA ROOM-WALL EXTENDS UP TO DECK-2 SETS OF LOCKSETS-AC-2 X3  FINISHED 1/2'  PAINTED PLYWOOD- RACK FOR PATCH PANELS AND SWITCHES-PATCH PANELS\nPROVIDE HANDRAILS ON WALL\nCORRIDORS SHALL BE BETWEEN 44-48 \nFURNITURE\nPROVIDE LAYOUT OF EQUIPMENT AND FURNITURE TO PINPOINT LOCATION OF POWER AND DATA OUTLETS\nBACKING SUPPORT SHALL BE REQUIRED FOR ALL FURNITURE AND EQUIPMENT.\nCASEWORK FOR ALL ROOMS EXCEPT DATA CLOSET, MR, CONFERENCE ROOM, TOUCHDOWN ROOM, STORAGE ROOM, CLEAN ROOM, V-TEL ROOM\nCASEWORK SHALL HAVE BASE AND WALL CABINETS WITH INTEGRATED STAINLESS SINK AND FAUCET IN ALL EXAM ROOMS, WOMEN S HEALTH, BLOOD LAB (CLEAN AND DIRTY COUNTERS W/SEPARATION BETWEEN THEM-USE PJ LAYOUT) AND DIRTY ROOM. ALL DRAWERS AND CABINET DOORS SHALL HAVE KEY LOCKS INSTALLED\nCASEWORK COUNTERTOP TO BE CORIAN-USE POUGHKEEPSIE SPEC FOR CABINETS\nRECEPTION AREA COUNTERTOPS TO BE CORIAN\nLOCKERS IN STAFF AREA-USE POUGHKEEPSIE SPEC-LOCKERS.COM- 12 LOCKERS\nElectrical Notes (Power-Lighting-Data-Communication)\nMINIMUM WIRE SIZE SHALL BE 12 GAGE AND CIRCUIT BREAKER SHALL BE 20 AMPS\nLAB AND PODIATRY SHALL HAVE EMERGENCY LIGHT BACKUP\nROOMS WITH NO WINDOWS SHALL HAVE EMERGENCY LIGHTS\nNURSE CALL   CALL FOR AID (LOCAL W/STROBE)   HARDWIRED   CONTROL AT RECEPTION AND LOCAL\nSEPARATE CAT6 RUNS FOR WALL PHONES AND COMPUTERS\nEACH RUN TO EACH ROOM SHALL HAVE A MINIMUM OF 3 CAT6 CABLES-EACH CABLE SHALL BE TERMINATED ON DIFFERENT WALLS OF THE ROOM\nPROVIDE CAT6 SHIELDED CABLE WITH ASSOCIATED SHIELDED CONNECTORS FOR VA PROVIDED WIFI ROUTERS THROUGHOUT THE CLINIC. A MINIMUM OF 12 ROUTERS WILL BE PROVIDED.\nPROVIDE (2) 3 PORT DATA OUTLETS IN EACH OF THE ROOMS\nFOR VISUAL FIELDS   3-PORT JACK (2+1)   CAMERA-1 PORT / EQUIPMENT-1 PORT\nFOR CVT ROOM   2-PORT JACK (NETWORK)\nWALL PHONES FOR ALL ROOMS   1 CAT 6E DROP FOR WALL-HUNG PHONE   ASK MARCOS FOR # OF PHONES\nSPECIFY DEDICATED OUTLETS (PYXIS, DATA, SHREDDER, STAFF LOUNGE (3-4)) AND INSTALLATION OF OUTLETS AS PER NEC CODE FOR MEDICAL OFFICES, I.E. OUTLET EVERY 6 FEET FROM EACH OTHER.\nPOWER OUTLETS FOR CABLE TV S\nINSTALL SUFFICIENT NUMBER OF DEDICATED OUTLETS (AT LEAST 5) BY KITCHEN COUNTERTOP FOR ALL APPLIANCES\nLIGHT FIXTURES SHALL BE 2 X2  LED WITH T8 LAMPS AND HIGH EFFICIENCY BALLASTS. OCCUPIED SPACES SHALL BE DESIGNED TO 50 FOOT CANDLES (FC) AND NON-OCCUPIED SPACES SHALL BE DESIGNED TO 10 FC MINIMUM. NON-OCCUPIED SPACES SHALL BE CONTROLLED BY AN INFRARED TYPE OCCUPANCY SENSOR AND OCCUPIED SPACES SHALL BE CONTROLLED BY TOGGLE SWITCHES.\nMINIMUM OF (4) LIGHT FIXTURES PER ROOM (2  X 2 ) WITH ENOUGH FOOT CANDLES ESPECIALLY PODIATRY\nLIGHT FIXTURES LOCATED NEAR FRONT AND REAR DOOR SHALL BE HARD WIRED TO A DEDICATED CIRCUIT, ENSURING ENTRY AND EXIT PASSAGE LIGHTING IS ALWAYS ON.\nEMERGENCY EGRESS LIGHTING AND ILLUMINATED EXIT SIGNS SHALL HAVE 90 MINUTES MINIMUM BATTERY BACKUP.\nALL WIRING FOR DATA AND TELECOMMUNICATIONS SHALL BE IN CONDUIT. LEAVE ABOUT 10-12 FEET OF EXCESS CABLES COILED IN THE DATA ROOM.\nEVERY ROOM SHALL HAVE A MINIMUM OF ONE 4-PORT DATA/VOICE RECEPTACLE. EXAM ROOMS, OFFICES, CONFERENCE ROOMS, WAITING AREA AND RECEPTION SHALL HAVE THREE 4-PORT DATA RECEPTACLE. EACH RECEPTACLE SHALL HAVE SIX CAT 6 CABLES AND SHALL BE LOCATED WITHIN 12  FROM 110 VOLT RECEPTACLE. BOTH CABLE ENDS SHALL BE LABELED.\nTHE DATA/PHONE ROOM WALL SURFACES SHALL BE LINED WITH FIRE RETARDANT PLYWOOD EXTENDING FROM 6  A.F.F. TO 8 -6  HIGH AND PAINTED BLACK, ROUTING OF CABLES SHALL BE IN CABLE TRAYS AND LOCATED ABOVE OR ADJACENT TO CORRIDORS AND BE ACCESSIBLE FROM A LADDER PLACED IN THE CORRIDOR FOR FUTURE MAINTENANCE.\nCABLES FOR CABLE TV SHALL BE PROVIDED IN CONDUIT FROM POINT OF ENTRY INTO THE CLINIC TO WAITING AREA AND CONFERENCE ROOMS. 110 VOLT RECEPTACLES SHALL BE PROVIDED TO POWER THE CABLE BOXES.\nCONTRACTOR SHALL ALSO INSTALL CONDUIT FOR ALL DATA AND TELECOMMUNICATION CABLE PULLS FROM THE UTILITY ROOM TO DATA ROOM CLOSET. ALL WIRING SHALL CONFORM TO THE BUILDING CODES LISTED ABOVE.\nINSTALL AND WIRE ALL ELECTRICAL OUTLETS PER VA PROPOSED LAYOUT.\nINSTALL AND WIRE ALL PHONE AND DATA OUTLETS PER VA PROPOSED LAYOUT, ALL WIRING SHALL BE CAT 6. A TRIPLE CONNECTION SHALL BE PULLED TO EACH LOCATION.\nTERMINATE DATA LINE IN ALL ROOMS AND LEAVE A 12 - 15FT NON-TERMINATED CABLE COIL IN THE DATA ROOM. ALL CABLES TO BE LABELED ON BOTH ENDS OF WIRE PULL\nALL OUTLETS SHALL BE HOSPITAL GRADE 20 AMP CIRCUITS UNLESS OTHERWISE SPECIFIED\nLIGHT FIXTURES LOCATED NEAR FRONT AND REAR DOOR SHALL BE HARD WIRED TO A DEDICATED CIRCUIT ENSURING ENTRY AND EXITING PASSAGE LIGHTING IS ALWAYS ON\nSHALL PROVIDE AND INSTALL BATTERY BACKUP (90 MINUTES MINIMUM) EMERGENCY EGRESS LIGHTING\nSHALL PROVIDE AND INSTALL ILLUMINATED EMERGENCY EXIT SIGNS WITH 90 MINUTES BATTERY BACKUP\nLAB AND PODIATRY SHALL HAVE EMERGENCY LIGHT BACKUP\nROOMS WITH NO WINDOWS SHALL HAVE EMERGENCY LIGHTS\nNURSE CALL   CALL FOR AID (LOCAL W/STROBE) - HARDWIRED\nPOWER OUTLETS EVERY 6 FEET   PER NEC\nKIOSK   DATA AND POWER\nHEALTHY VET DESK   DATA AND POWER (CONFIRM W/SHATHA)\nEACH RUN TO EACH ROOM SHALL HAVE A MINIMUM OF 3 CAT6 CABLES-EACH CABLE SHALL BE TERMINATED ON DIFFERENT WALLS OF THE ROOM\nPYXIS/EKG   DEDICATED CIRCUITS\nSPECIFY DEDICATED OUTLETS FOR DATA, SHREDDER, STAFF LOUNGE (3-4)) AND INSTALLATION OF OUTLETS AS PER NEC CODE FOR MEDICAL OFFICES, I.E. OUTLET EVERY 6 FEET FROM EACH OTHER.\nDATA CLOSET   PHONES:\nPROVIDE WIRING IN CONDUIT FOR ALL CABLES FROM BUILDING DEMARCATION ROOM TO THE DATA CLOSET\nFIRE STOP ALL PENETRATIONS IN CEILING WALLS AND FLOORS.\nPROVIDE 2  X 3 - Â¾  PAINTED PLYWOOD ON WALL PROVIDE SMOKE DETECTOR INSIDE DATA CLOSET\nPROVIDE LAYOUT OF EQUIPMENT AND FURNITURE TO PINPOINT LOCATION OF POWER AND DATA OUTLETS\nRACK FOR PATCH PANELS AND NETWORKING EQUIPMENT\nDEDICATED OUTLETS (3)   20AMP\nDEDICATED AC UNIT\nALARM ON THE OUTSID INSTALL HI-TEMP LOCAL ALARM W/FEATURE TO SILENCE AND BYPASS. INSTALL STROBE AND HORN OUTSIDE W/SIGN  HI TEMP \nBACKUP THERMOSTATICALLY CONTROLLED EXHAUST FAN W/AUDIO AND VISUAL ALARM IF IT COMES ON AND SILENCE BUTTON\nCAT6 CABLES FOR MINIMUM OF 8 WI-FI ROUTERS   LOCATION TO BE DETERMINED BY VA\nCAT6 CABLE DROPS FOR EACH ROOM   2 FOR DATA OUTLET AND 1 FOR WALL PHONE\nALL CAT6 CABLES SHALL BE PLENUM RATED OR IN CONDUIT.\nPlumbing / HVAC Notes\nUNLESS OTHERWISE SPECIFIED, ALL SINKS SHALL HAVE WRIST BLADE CONTROL HANDLES, HOT AND COLD WATER SUPPLY AND PROPER DRAINAGE.\nSINKS LOCATED WITHIN RESTROOMS SHALL BE ADA COMPLIANT. FAUCET HARDWARE SHALL BE ADA COMPLIANT. FOOT PEDALS ARE NOT REQUIRED. ALL TOILETS INSTALLED SHALL BE OF PROPER ADA HEIGHT.\nSINK LOCATED IN THE STAFF ROOM SHALL BE A DOUBLE STAINLESS STEEL SINK WITH KITCHEN FAUCET AND SPRAY HOSE. FOOT PEDALS ARE NOT REQUIRED.\nPLUMBING FIXTURES SHALL BE  LOW FLOW  TYPE AND THE HOT WATER SYSTEM SHALL BE LOOPED FOR RECIRCULATION. ELECTRONIC FLUSH VALVES AND FAUCETS SHALL BE PROVIDED FOR ALL FIXTURES. EXAM ROOM SINKS SHALL HAVE GOOSENECK SPOUTS AND PEDAL OPERATED FAUCETS.\nPROVIDE HI-RISE TOILETS AND COVERS FOR PIPING.\nPROVIDE CHILLED WATER BOTTLING STATIONS IN WAITING AREA, WITH POWER, COLD WATER SUPPLY AND DRAINAGE.\nPROVIDE FILTRATION AND MAINTENANCE FOR REFRIGERATED WATER BOTTLING STATIONS.\nJANITORIAL CLOSET SHALL HAVE A FLOOR MOUNTED MOP SINK INSTALLED CONNECTED TO DRAINAGE SYSTEM. THERE SHALL BE A WALL MOUNTED JANITORIAL FAUCET INSTALLED WITH HOT AND COLD WATER SERVICE.\nALL ROOMS OF THE SUITE SHALL HAVE HVAC DIFFUSERS AND RETURNS PROPERLY SIZED FOR THE ROOM.\nTHE HVAC SYSTEM SHALL BE DESIGNED TO PROVIDE INDIVIDUALLY CONTROLLED THERMOSTATS EACH WITH ITS OWN VAV FOR ALL OCCUPIED SPACES (EXAM TYPE ROOMS, RECEPTION, WAITING AREA). UNOCCUPIED SPACES (RESTROOMS, STORAGE, JANITOR, SOILED LINEN ROOM) MAY BE GROUPED WITH NO MORE THAN 4 ROOMS ON ANY ONE VAV. SUPPLY, EXHAUST AND RETURN AIR SYSTEMS SHALL BE DUCTED.\nEXHAUST SYSTEM SHALL BE REQUIRED FOR RESTROOMS, WAITING AREA, DATA ROOM AND OTHERS.\nPOSITIVE AND NEGATIVE AIR PRESSURES FOR CLEAN AND DIRTY ROOMS\nAIR CHANGES REQUIREMENT   TAB REPORT (TESTING AND BALANCING)\nMAKE PROVISION FOR FRESH OUTDOOR AIR\nPROVIDE (4) SEPARATE ZONES FOR FRONT (RECEPTION AND LOBBY), REAR AND ONE EACH FOR THE 2 INTERIOR CORRIDORS HYDRONIC SYSTEM W/HUMIDIFIER\nPROVIDE Testing and Balancing reports BY CERTIFIED CONTRACTOR\nPROVIDE DUCT LEAKAGE INSPECTION AND REPORT\nCLEAN AND DIRTY ROOMS   POSITIVE AND NEGATIVE AIR\nFire Sprinkler and Fire Alarm Notes\nBUILDING SHALL BE FULLY SPRINKLERED AND THE DESIGN MUST BE CERTIFIED BY AN INDEPENDENT NEW YORK STATE LICENSED FIRE PROTECTION ENGINEER AND APPROVED BY THE LOCAL FIRE DEPARTMENT AND THE VA.\nCONTRACTOR SHALL INSTALL FIRE SPRINKLER SYSTEM AS PER THE NFPA 13 AND LIFESAFETY DEVICES.\nTHE FIRE ALARM SYSTEM SHALL COMPLY WITH THE LOCAL FIRE DEPARTMENT AND SHALL BE TIED TO THE HVAC SYSTEM TO SHUT THE UNIT DOWN. BATTERY BACKUP SHALL BE PROVIDED.\nPROVIDE FULLY RECESSED FIRE EXTINGUISHER CABINETS\nPROVIDE SHALL PROVIDE AND INSTALL APPROVED FIRE EXTINGUISHERS IN CABINETS\nALL PENETRATIONS FROM MECHANICAL ROOMS, STORAGES, JANITORIAL AND/OR SUITE TO SUITE SHALL BE PROPERLY FIRE SEALED\nSecurity System Notes\nTHE BURGLAR ALARM SYSTEM SHALL DETECT ENTRY AT EITHER FRONT OR REAR ENTRY/EXIT DOORS. AND ALSO DETECT BROKEN GLASS IN AREAS WHICH ARE RELATIVELY ACCESSIBLE. THE SYSTEM SHALL INTERFACE WITH THE LOCAL POLICE DEPARTMENT AS WELL AS THE VA POLICE DEPARTMENT. ALL SECURITY WIRING SHALL BE IN CONDUIT.\nAN ELECTRONIC PERSONNEL PROTECTION SYSTEM SHALL BE A DURESS-PANIC ALARM TYPE. EMERGENCY BUTTONS SHALL BE LOCATED AT THE RECEPTION DESK. A CCTV SYSTEM WITH AN NVR SHALL BE EMPLOYED TO MONITOR ALL EXTERIOR DOORS AND MAIN LOBBY.\nPROVIDE SECURED MAILBOX\nCONTRACTOR SHALL HAVE A BURGLAR ALARM SYSTEM INSTALLED FOR THE OCCUPIED SPACES\nA. DETECT ENTRY ON EITHER FRONT OR REAR ENTRY/EXIT DOORS\nB. DETECT BROKEN WINDOW ON AREAS WERE RELATIVELY ACCESSIBLE\nPROVIDE INTRUSION, PANIC AND CCTV\n  FSL LEVEL 2   CCTV-PANIC-INTRUSION   COORDINATE WITH VA VENDOR\n  FSL LEVEL 3 - BOLLARDS   VA SPEC (4000 LBS)\nTESTING:\n  PRIOR TO OCCUPANCY, PROVIDE THE FOLLOWING INSPECTIONS, TESTS AND DETAILED REPORTS. THE INSPECTION AND TESTING AGENCIES SHALL BE AN INDEPENDENT THIRD PARTY AND SHALL BE LICENSED AND CERTIFIED BY NEW YORK STATE. A MINIMUM OF 3 AGENCIES SHALL BE SUBMITTED TO THE VA COR FOR REVIEW AND APPROVAL AND SELECTION OF THE AGENCY.\n1. CERTIFICATE OF OCCUPANCY\n2. DUCT LEAKAGE TEST\n3. TESTING AND BALANCING\n4. AIR QUALITY TESTING\n5. WATER TESTING\n6. FIRE INSPECTION","origin":"detail"},"contacts":[{"name":"Charles Bergeman","role":"primary","email":"charles.bergeman@va.gov","phone":"585-393-8395","title":"Contracting Officer"}],"place_of_performance":{"zip":"10512","street":"Carmel, NY","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["531120"],"award":{"awardee":{}},"attachments":[{"resource_id":"277e95c65b904c479b0aeaa3c4f34226","name":"36C24225R0019.docx","kind":"file","mime_type":".docx","size_bytes":343960,"posted_at":"2025-12-15T14:32:45.479Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/277e95c65b904c479b0aeaa3c4f34226/download","mirrored":false}],"awards":[],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"6NY0452A","latest_notice_id":"be241405bde7418f90db8c54dece2e59","title":"US Government seeks to Lease Office Space in Holtsville, NY","solicitation_number":"6NY0452a","notice_type":"p","first_type":"p","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T22:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-047","dept_name":"GENERAL SERVICES ADMINISTRATION","sub_key":"s-4740","sub_name":"PUBLIC BUILDINGS SERVICE","office_key":"o-47PA05","office_name":"PBS R00 CENTER FOR BROKER SERVICES","naics":"531120","psc":"X1AA","set_aside":null,"state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":"title","state_evidence":"US GOVERNMENT SEEKS TO LEASE OFFICE SPACE IN HOLTSVILLE, NY","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"4NY0720","latest_notice_id":"24ab0bcda44347bb9771097e285336fa","title":"Solicitation for Leased Office Space in Hudson, NY","solicitation_number":"4NY0720","notice_type":"o","first_type":"p","first_posted":"2025-08-15","last_posted":"2026-11-18","notices":4,"due_at":"2026-12-04T04:59:00Z","due_date":"2026-12-03","closes_at":"2026-12-04T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-047","dept_name":"GENERAL SERVICES ADMINISTRATION","sub_key":"s-4740","sub_name":"PUBLIC BUILDINGS SERVICE","office_key":"o-47PA99","office_name":"PBS OFFICE OF LEASING","naics":"531120","psc":"X1AA","set_aside":null,"state":"NY","county":"36021","county_name":"Columbia County","city":"3635969","city_name":"Hudson","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open_total":64,"indexable":false}