{"canonical":"https://sealedbidder.com/opportunities/36c24225q1030","key":"36C24225Q1030","url":"https://sealedbidder.com/opportunities/36c24225q1030","title":"J063--Security Systems PM, Repair and Support Albany VA Medical Center, Albany, NY Base Plus 4 Option Years","solicitation_number":"36C24225Q1030","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-09-04T19:00:00Z","first_posted":"2025-08-28","last_posted":"2025-08-28","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"561621","psc":"J063","set_aside":null,"place_state":"NY","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"36001","place_county_name":"Albany County","place_city":"3601000","place_city_name":"Albany","winner":null,"award_amount":null,"publications":[{"notice_id":"67ffd9fcca6d4088aa64fe22d9b48def","title":"J063--Security Systems PM, Repair and Support Albany VA Medical Center, Albany, NY Base Plus 4 Option Years","solicitation_number":"36C24225Q1030","notice_type":"r","base_type":"r","posted":"2025-08-28","posted_at":"2025-08-28T17:46:19.922Z","due_at":"2025-09-04T19:00:00Z","due_date":"2025-09-04","cancelled":false,"archived":true,"archive_date":"2025-11-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/67ffd9fcca6d4088aa64fe22d9b48def/view","enriched":true,"history":[{"index":3,"title":"J063--Security Systems PM, Repair and Support Albany VA Medical Center, Albany, NY Base Plus 4 Option Years","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-28T17:46:19.922Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"67ffd9fcca6d4088aa64fe22d9b48def","solicitation_number":"36C24225Q1030"}]}],"latest_notice_id":"67ffd9fcca6d4088aa64fe22d9b48def","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-08-28","posted_at":"2025-08-28T17:46:19.922Z","created_at":"2025-08-28T17:46:17.676Z","modified_at":"2025-11-04T04:55:45.159Z","response_deadline":{"raw":"2025-09-04T15:00:00-04:00","utc":"2025-09-04T19:00:00Z","date":"2025-09-04","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/67ffd9fcca6d4088aa64fe22d9b48def/view"},"naics":{"codes":["561621"],"primary":"561621"},"title":"J063--Security Systems PM, Repair and Support Albany VA Medical Center, Albany, NY Base Plus 4 Option Years","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-11-03","archive_type":"auto_custom"},"history":[{"index":3,"title":"J063--Security Systems PM, Repair and Support Albany VA Medical Center, Albany, NY Base Plus 4 Option Years","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-08-28T17:46:19.922Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"67ffd9fcca6d4088aa64fe22d9b48def","solicitation_number":"36C24225Q1030"}],"contacts":[{"name":"Julie Monagan Barnard","role":"primary","email":"julie.monaganbarnard@va.gov","phone":"(607) 590-1325","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"67ffd9fcca6d4088aa64fe22d9b48def","lineage_id":"67ffd9fcca6d4088aa64fe22d9b48def","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-02T01:56:05.796334708Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"865ba2b3e1272b7fcbd40bb710b75bcd81c1e53cec8742362026dbca5529b5fd","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-02T01:56:05.796334708Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Performance Work Statement (PWS)\nSecurity Systems Preventive Maintenance, Repair Service, and Support\nAlbany Stratton VA Medical Center\nAlbany, New York\n1. Background\nThe Albany VA Medical Center seeks to procure a contract for software, technical services, maintenance, repairs, and upgrades for its integrated security infrastructure.  This includes the Milestone Video Surveillance System (VASS), Lenel Physical Access Control System (PACS), Lynx Keyboard Alarm System, Traka Key Control System, and the Zenitel AlphaCom Intercom system.\nThe purpose of this contract is to:\nThis contract ensures the reliable operation and timely service of the VAMC-Albany Security Systems Infrastructure, explicitly addressing the upkeep and repair of security, surveillance, access control, and intercom devices.\n2. Scope of Work\nThe Contractor must support and maintain the existing integrated security infrastructure, which includes the Milestone Video Surveillance System (VASS), Lenel Physical Access Control System (PACS), Lynx Keyboard Alarm System, Traka Key Control System, and the Zenitel AlphaCom Intercom system installed at the Albany Stratton Medical Center. \nThe contractor must manage a service request response system for maintenance requests. Before conducting any work at the Albany Office, the contractor must employ maintenance personnel who are trained and certified in the use and operation of all security, access control, and video surveillance equipment located within the facility and listed in Appendix B. \n The contractor must provide preventative maintenance and repairs supporting the Albany VAMC Medical Center's integrated security infrastructure at 113 Holland Avenue, Albany, New York. The contractor must provide all necessary resources to maintain and repair the existing systems, including labor, supervision, equipment, tools, materials, supplies, travel, and transportation required for system maintenance and repairs. Repair and replacement parts must be included. Systems functionality must be achieved upon completion of the first service call. Functionality is defined as a working system as designed, but may be accomplished with any part available to the Technician at the time of service. Only when repair is not possible during a service call can a loaner (or equal) part be used to regain system functionality. \n\n3. Service Requirements\na. Standard Service Calls:\n- Acknowledge service calls within 4 hours.\n- Respond and restore service within 2 days.\n- Regular business hours: Mon Fri, 8:00 am   5:00 pm.\n\nb. Emergency Service Calls:\n- Acknowledge within 4 hours.\n- Respond and restore service within 8 hours.\n- Applicable 7 days/week.\n\nc. Preventive Maintenance:\n- Quarterly preventive maintenance is performed during weekday business hours.\n- Must include system inspection, cleaning, adjustment, battery testing/replacement, hard drive checks, firmware/software updates, and final test runs.\n\nDue to the contract's required response and repair times, vendors must utilize technicians who dispatch from a work site or base location with available resources and equipment within a 60-mile radius of the Albany Stratton VAMC. \n\nWork performed by Contractor personnel under the terms of this contract shall not interfere with regularly scheduled government operational activities. \n4. Specific Tasks and Deliverables \nThe contractor must obtain all necessary equipment, parts, and manufacturer's specifications and create as-built drawings to manage the facilities' existing integrated security infrastructure, maintenance, and repair as required. See the equipment list in Appendix B. \nThe contractor must provide the Government COR with the Contractor s technical support number and one Point of Contact (POC) for service and account representation. The POC must provide customer service to VA for all questions or concerns related to this requirement. \nThe contractor must perform maintenance services and repairs Monday through Friday during regular business hours, 8:30 A.M. through 5:00 P.M. EST, and must commence no later than 1:00 P.M. EST. \nThe Contractor must advise the COR of potential delays in completing any aspects of the repair and provide recommendations on actions necessary to keep the task on schedule. \nThe Contractor must perform quarterly preventive maintenance on all listed systems during the contract. This must include manual inspection and testing of all systems, with inspection and testing reports regularly updated in accordance with manufacturer recommendations. The maintenance must also include site visits to modify or replace any system component. The contractor must provide the COR with a site visit report listing all updates and corrective actions. The contractor must verify the operation of the systems with the COR upon completion of work. \nThe contractor must repair or replace any equipment (listed in Appendix B) as necessary to ensure it remains fully functional and operates according to the manufacturer s specifications. To maintain proper operation, the contractor must ensure all system equipment is configured correctly.\nFurnish all labor, tools, certifications, safety gear, software, replacement parts, and plenum-rated cabling.\nThe Contractor must maintain an on-site inventory of replacement parts suitable for the security equipment. Replacement parts are included at no additional cost to the Government. All replaced equipment is the property of the VA and must be provided to the Contracting Officer s Representative (COR) when deemed necessary. \nOpen a Vendor Credentialing Service (VCS) account and comply with VA background check and access procedures.\nPerform monthly preventive maintenance (PM), including maintaining and creating full backups of the SQL server databases, updating and maintaining Windows Server software, and installing security patches and updates to the security system software and hardware. \nProvide necessary software and hardware upgrades, as well as reprogramming, to maintain compliance with the VA Technical Reference Model.   \nMaintain support service agreements and yearly device licensing for the following, as listed in Appendix A\n Lenel S2   Software Support Agreement and device licensing\n Milestone   Software Support Agreement and device licensing\n Traka Yearly Software License for three cabinets\nLynx Software License\n\nThe contractor must provide technicians with up-to-date certifications: Lenel LCA, LCP, LCE, LCDA, Milestone, Zenitel AlphaCom.\nProvide 600 on-site labor hours annually, including at least 40 PM hours each quarter. Any unused hours will be credited back to the Government as funds available for purchasing security equipment. This audit and credit will occur monthly. \nThe contract must include provisions for the new installation of PACS or VASS.\n a. New access controls for three doors are installed per year.\nTypical installation as an example: \nSolid wood door, BEST cylindrical or mortise electrified lockset, pivCLASS reader, LNL-1320 Series 3 Dual Reader Interface Module, cross-drill door, 24V Power supply cabinet with battery backup, door position sensor, request to exit, 200 feet of composite cabling. \n b. New camera installation for three locations per year.\nTypical VASS installation as an example:\nHanwha QNV-7022R 4MP Network IR Vandal-Resistant Camera, with Cat6 wiring typically under 100 feet to a network switch. \nProvide an equipment fund paid for by the contract to include frequently used items such as HID iCLASS Proximity Cards, HID iCLASS Proximity FOBS, and HID FARGO Ribbon Consumables for the HID FARGO DTC4500e printer.  \nTypical annual equipment failure rates:\nCameras: 4\nPOE Injectors: 4\nPOE Surge protectors: 5\nPIV Card Readers: 6\nDoor Locksets: 4\n24V Power Supplies: 5\nDoor Relays: 6\nWall/Computer monitors: 2\n5. Government-Furnished Resources\nNone\n6. Reporting Requirements\nQuality Control:  Quality Control is the responsibility of the Contractor. The Contractor is responsible for delivering quality services/supplies to the Government (see FAR 52.246-1 Contractor Inspection Requirements). The Contractor shall develop, implement, and maintain a Quality Control Program (QCP) to ensure all work described in this contract is performed at or above the standard defined in the Performance Requirements Summary (PRS).  \nQuality Control Program. The Contractor shall develop, implement, and maintain an effective Quality Control System, a written Quality Control Plan (QCP). The QCP shall implement standardized procedures and methodologies for monitoring and documenting contract performance to meet all contract requirements. The Contractors  QCP shall contain a systematic approach to monitor operations to ensure acceptable services, supplies, and products described in the contract are performed at or above the standards defined in the PWS and Performance Requirements Summary (PRS).\nThe Contractor shall submit their QC Plan no later than (NLT) 10 days after contract award and within five (5) days of any proposed changes. The QCP shall be submitted by the contractor to the Contracting Officer (CO) and Contracting Officer Representative (COR) if it was not already furnished as part of the initial proposal/award package.  QCP shall be submitted to the CO and COR within 5 working days when changes are made thereafter. After acceptance of the QC Plan, the contractor shall receive the Contracting Officer s approval in writing of any proposed change to their QC system. The Contractor s QCP shall be incorporated into and become part of this contract after the CO/COR has accepted the plan. Proposed changes made after CO/COR acceptance shall be submitted in writing through the COR to the CO for review and approval before implementing any revision.  The Contractor s QCP shall be maintained throughout the contract's life and shall include the Contractor s procedures to routinely evaluate the plan's effectiveness to ensure the Contractor is meeting the performance standards and requirements of the contract.  \nContractor s organizational and management structure, titles, responsibilities, and qualifications, work, and quality control verification. A comprehensive program to plan and deliver quality services/supplies described in the contract, prioritize services, and concentrate on the most essential services identified in the Performance Requirements Summary (PRS).\nDescribe a method, acceptable to the Government, of identifying deficiencies in the quality of service performed under the contract before the level of performance becomes unacceptable.  Describe a method for preventing and addressing processes for corrective actions without dependence upon Government direction.  Contain specific quality control techniques for contract services or supplies identified in the PRS.\nAn established inspection system covering all services required by the contract.  The plan shall specify areas to be inspected on both a scheduled and unscheduled basis, as well as the title of the individual who will do the inspection.  Maintain a system to examine their subcontractor services and products to ensure compliance with contract requirements and applicable laws and regulations. Specify tasks or areas to be inspected on a scheduled or unscheduled basis, and how inspections will be conducted. The contractor shall provide a current list of all titled positions, the names of the incumbents who will perform the inspections, and the percentage of the work that will be inspected regularly.\nThe contractor shall keep records of all inspection files conducted by the contractor and the necessary corrective action taken. The contractor shall maintain documentation of all contractor quality control inspections and corrective actions throughout the term of this contract.\nThe QCP shall have a customer comment processing system to correct Contracting Officers Representative (COR) validated comments received via email. The system should be designed to provide feedback to the Government based on customer contact, investigation of derogatory comments, rebuttal to derogatory comments, or corrective action(s).  \nNon-Conformance Report (NCR).  When the Contractor's performance is unsatisfactory, a Contract Discrepancy Report (CDR) will be issued.  The Contractor shall reply in writing within five (5) workdays from the date of receipt of the CDR, giving the reasons for the unsatisfactory performance, corrective action taken, and procedures to prevent recurrence.\nQuality Assurance:  The COR will evaluate the Contractor s performance under this contract in accordance with the Quality Assurance Surveillance Plan (QASP).  This plan is primarily focused on what the COR must do to ensure that the Contractor has performed in accordance with the performance standards.  It defines how the performance standards will be applied, the frequency of surveillance, and the minimum acceptable defect rate(s). When an observation indicates defective performance, the COR will require the Contractor or designated on-site representative to initial the observation to acknowledge the defective performance.  The acknowledgement of the observation does not necessarily constitute Contractor concurrence with the observation, only that the Contractor has been made aware of the defective performance. Clauses of FAR 52.246-1, Inspection of Supplies -Fixed Price and FAR 52.246-4, Inspection of Services -Fixed-Price shall be followed as an assisting means of determination for the quality of worked performed.\nContractor shall submit field service reports to the COR, including:\nArrival/departure times\nEquipment serviced (type, model, serial)\nMaintenance details\nParts replaced\nDuration of Service\n\nThe contractor shall provide monthly audit reports of man-hours utilized for the month and current equipment fund balances. The report must include an itemized list of equipment purchases. It is due on the 15th of the month for the prior month of service.\n7. System Modifications\nAny proposed system changes must be submitted in writing to the COR. Approved modifications must be reflected in updated operations and maintenance documentation.\n8. Qualifications\nService personnel must:\nHold technician certifications with Lenel, Milestone, and Zenitel Stentfon\nMicrosoft Certified: Windows Server Hybrid Administrator Associate. \nUnderstand VA policies for safety, emergency response, and facility procedures.\nProvide qualifications and job descriptions before service initiation.\n9. Place of Performance\nStratton VA Medical Center\n113 Holland Avenue\nAlbany, NY 12208\n\nSPECIAL NOTE: Albany Stratton s Integrated Security System and all of its components, including servers, are not accessible via REMOTE connections of any type. ALL services MUST be performed ONSITE.\n10. Period of Performance\nThe performance period must be 12 months, with four 12-month optional periods of performance.\nBase Year + Four (4) optional one-year renewals at government discretion\nThere are eleven (11) Federal holidays set by law (USC Title 5 Section 6103) that VA follows: \nUnder current definitions, five (5) are set by date:\nNew Year s Day January 1, \nJuneteenth  June 19,\nIndependence Day July 4,\nVeterans Day  November 11, \nChristmas Day  December 25,\n\n If any of the above dates falls on a Saturday, then Friday must be observed as a holiday. Similarly, if any of the above dates falls on a Sunday, then Monday must be observed as a holiday.\n The other six (6) are set by a day of the week and month:\n Martin Luther King's Birthday  Third Monday in January \nWashington's Birthday   Third Monday in February\nMemorial Day    Last Monday in May\nLabor Day    First Monday in September\nColumbus Day    Second Monday in October\nThanksgiving     Fourth Thursday in November\n11. System Inventory\nAttachment B\n12. Software Licenses\nAttachment A\n\n\n\n\n\n\n\nAttachment A\n\nSystem Software Required to be maintained:\nAnnual Licenses to be supplied: \n\nMicro Technology Lynx: \nStandard 7.24.09.1\nAlbany VA Medical Center LYNX-702283\nExpiration Date: 7/1/2026\n10,000 Lynx Guide Server Seats\n4000 Lynx KeyPro Seats\n10 Lynx Messenger Pro seats\n10 LynxIcon Pro seats\n\nMilestone Care Plus Service Agreement \nXProtect Expert 2023 R2\nExpiration Date: 1/30/2026\nSLC: M01-C02-232-01-6C4267\nDevice licenses 261 used out of 304\n\nLenel S2 OnGuard Enterprise Software Support Agreement\nExpiration Date: 9/30/2025\nProduct version 8.1.639.468 \nDongle ID 86170\n\nTraka Annual Software License\nTrakaWeb  ver 4.1.3\nSoftware Expiration Date: 1/9/2026\n3 Key Cabinets\nCustomer Code: 12280\n\nZenitel AlphaCom Core\n17 Stations in license   8 in use \n\n\nAttachment B  1\nPerformance Requirements Summary (PRS)\nSystem Hardware\nAccess Control \nLenel OnguardS2\n1 Server Dell EMC PowerEdge R740\n5 Workstations (Client Computers for Alarm Monitoring and Administration)\n12 Lenel Advanced Dual Reader Controller Board LNL-X4420\n10 Lenel-3300 Intelligent System Controller (old Series 1 and 2)\n1 Lenel x3300 Intelligent System Controller (series 3)\n6 Lenel x2220 Intelligent System Controller (series 3)\n68 Lenel LNL-1300 Single Reader Interface Module\n98 Lenel LNL-1320 Dual Reader Interface Module \n87 Lenel 2020 Magnetic Stripe readers \n162 pivCLASS RK40-H Weigand PIV card readers\n\nVideo Surveillance \n3 Husky IVO 1800R Video Recording Servers- 288TB each\n277 Cameras   1 out of service\nWisenet PNM-9084RQZ1\n62\nWisenet PNM-7082RVD\n2\nAxis P3346\n58\nAxis P3225-LVE Mk II\n2\nWisenet PNM-7002VD\n47\nAxis Q1615 MK ii\n1\nWisenet XNV-C6083R\n47\nAxis P3715-PLVE\n1\nWisenet XNP-6400\n12\nAxis P3215-V\n1\nAxis M5525-E-PTZ\n7\nAxis Q6042-E PTZ\n1\nAxis Q3617\n6\nAxis Q1614\n1\nAxis P3364-L\n6\nAxis Q6044-E\n1\nAxis P3717-PLE\n4\nAxis P1377\n1\nWisenet QND-8010R\n3\nAxis P1378-LE\n1\nAxis P3245-V\n3\n Axis P3367\n1\nAxis Q6075-E PTZ\n3\nAxis P3727-PLE\n1\nAxis M3025\n2\nAxis P5635-E-Mk ii\n1\nAxis M3066-V\n2\n\n\n\n\nAttachment B 2\nTraka Key Control System\nDatabase stored on Lenel Server as SQL Table\nFront End Running on Dell Precision Tower 5510\nClients run on Workstations shared with Lenel, 5 Workstations\n1 60- Position Electronic Key Cabinet\n1 120- Position Electronic Key Cabinet\n1 40- Position Electronic Key Cabinet\n\nZenitel AlphaCom Intercom System\nAlphaCom XE1 Audio Server with HD Voice\nWeb Client AlphaWeb XE\n5 Intercoms\n3 Desk Stations\n\nLynx Keyboard Duress Alarm System\nLynx Server is maintained on a VA Virtual Server\nLynx Clients installed on all Albany VAMC computers \n\nBalance\nTotal \nUsed\nBalance\nLynxGuide Server Seats\n10000\n5226\n4774\nLynxKeyPro\n4000\n2606\n1394\nLynxMessengerPro\n10\n0\n10\nLynxIconPro\n10\n0\n10","text":"Performance Work Statement (PWS)\nSecurity Systems Preventive Maintenance, Repair Service, and Support\nAlbany Stratton VA Medical Center\nAlbany, New York\n1. Background\nThe Albany VA Medical Center seeks to procure a contract for software, technical services, maintenance, repairs, and upgrades for its integrated security infrastructure. This includes the Milestone Video Surveillance System (VASS), Lenel Physical Access Control System (PACS), Lynx Keyboard Alarm System, Traka Key Control System, and the Zenitel AlphaCom Intercom system.\nThe purpose of this contract is to:\nThis contract ensures the reliable operation and timely service of the VAMC-Albany Security Systems Infrastructure, explicitly addressing the upkeep and repair of security, surveillance, access control, and intercom devices.\n2. Scope of Work\nThe Contractor must support and maintain the existing integrated security infrastructure, which includes the Milestone Video Surveillance System (VASS), Lenel Physical Access Control System (PACS), Lynx Keyboard Alarm System, Traka Key Control System, and the Zenitel AlphaCom Intercom system installed at the Albany Stratton Medical Center.\nThe contractor must manage a service request response system for maintenance requests. Before conducting any work at the Albany Office, the contractor must employ maintenance personnel who are trained and certified in the use and operation of all security, access control, and video surveillance equipment located within the facility and listed in Appendix B.\nThe contractor must provide preventative maintenance and repairs supporting the Albany VAMC Medical Center's integrated security infrastructure at 113 Holland Avenue, Albany, New York. The contractor must provide all necessary resources to maintain and repair the existing systems, including labor, supervision, equipment, tools, materials, supplies, travel, and transportation required for system maintenance and repairs. Repair and replacement parts must be included. Systems functionality must be achieved upon completion of the first service call. Functionality is defined as a working system as designed, but may be accomplished with any part available to the Technician at the time of service. Only when repair is not possible during a service call can a loaner (or equal) part be used to regain system functionality.\n\n3. Service Requirements\na. Standard Service Calls:\n- Acknowledge service calls within 4 hours.\n- Respond and restore service within 2 days.\n- Regular business hours: Mon Fri, 8:00 am 5:00 pm.\n\nb. Emergency Service Calls:\n- Acknowledge within 4 hours.\n- Respond and restore service within 8 hours.\n- Applicable 7 days/week.\n\nc. Preventive Maintenance:\n- Quarterly preventive maintenance is performed during weekday business hours.\n- Must include system inspection, cleaning, adjustment, battery testing/replacement, hard drive checks, firmware/software updates, and final test runs.\n\nDue to the contract's required response and repair times, vendors must utilize technicians who dispatch from a work site or base location with available resources and equipment within a 60-mile radius of the Albany Stratton VAMC.\n\nWork performed by Contractor personnel under the terms of this contract shall not interfere with regularly scheduled government operational activities.\n4. Specific Tasks and Deliverables\nThe contractor must obtain all necessary equipment, parts, and manufacturer's specifications and create as-built drawings to manage the facilities' existing integrated security infrastructure, maintenance, and repair as required. See the equipment list in Appendix B.\nThe contractor must provide the Government COR with the Contractor s technical support number and one Point of Contact (POC) for service and account representation. The POC must provide customer service to VA for all questions or concerns related to this requirement.\nThe contractor must perform maintenance services and repairs Monday through Friday during regular business hours, 8:30 A.M. through 5:00 P.M. EST, and must commence no later than 1:00 P.M. EST.\nThe Contractor must advise the COR of potential delays in completing any aspects of the repair and provide recommendations on actions necessary to keep the task on schedule.\nThe Contractor must perform quarterly preventive maintenance on all listed systems during the contract. This must include manual inspection and testing of all systems, with inspection and testing reports regularly updated in accordance with manufacturer recommendations. The maintenance must also include site visits to modify or replace any system component. The contractor must provide the COR with a site visit report listing all updates and corrective actions. The contractor must verify the operation of the systems with the COR upon completion of work.\nThe contractor must repair or replace any equipment (listed in Appendix B) as necessary to ensure it remains fully functional and operates according to the manufacturer s specifications. To maintain proper operation, the contractor must ensure all system equipment is configured correctly.\nFurnish all labor, tools, certifications, safety gear, software, replacement parts, and plenum-rated cabling.\nThe Contractor must maintain an on-site inventory of replacement parts suitable for the security equipment. Replacement parts are included at no additional cost to the Government. All replaced equipment is the property of the VA and must be provided to the Contracting Officer s Representative (COR) when deemed necessary.\nOpen a Vendor Credentialing Service (VCS) account and comply with VA background check and access procedures.\nPerform monthly preventive maintenance (PM), including maintaining and creating full backups of the SQL server databases, updating and maintaining Windows Server software, and installing security patches and updates to the security system software and hardware.\nProvide necessary software and hardware upgrades, as well as reprogramming, to maintain compliance with the VA Technical Reference Model.\nMaintain support service agreements and yearly device licensing for the following, as listed in Appendix A\nLenel S2 Software Support Agreement and device licensing\nMilestone Software Support Agreement and device licensing\nTraka Yearly Software License for three cabinets\nLynx Software License\n\nThe contractor must provide technicians with up-to-date certifications: Lenel LCA, LCP, LCE, LCDA, Milestone, Zenitel AlphaCom.\nProvide 600 on-site labor hours annually, including at least 40 PM hours each quarter. Any unused hours will be credited back to the Government as funds available for purchasing security equipment. This audit and credit will occur monthly.\nThe contract must include provisions for the new installation of PACS or VASS.\na. New access controls for three doors are installed per year.\nTypical installation as an example:\nSolid wood door, BEST cylindrical or mortise electrified lockset, pivCLASS reader, LNL-1320 Series 3 Dual Reader Interface Module, cross-drill door, 24V Power supply cabinet with battery backup, door position sensor, request to exit, 200 feet of composite cabling.\nb. New camera installation for three locations per year.\nTypical VASS installation as an example:\nHanwha QNV-7022R 4MP Network IR Vandal-Resistant Camera, with Cat6 wiring typically under 100 feet to a network switch.\nProvide an equipment fund paid for by the contract to include frequently used items such as HID iCLASS Proximity Cards, HID iCLASS Proximity FOBS, and HID FARGO Ribbon Consumables for the HID FARGO DTC4500e printer.\nTypical annual equipment failure rates:\nCameras: 4\nPOE Injectors: 4\nPOE Surge protectors: 5\nPIV Card Readers: 6\nDoor Locksets: 4\n24V Power Supplies: 5\nDoor Relays: 6\nWall/Computer monitors: 2\n5. Government-Furnished Resources\nNone\n6. Reporting Requirements\nQuality Control: Quality Control is the responsibility of the Contractor. The Contractor is responsible for delivering quality services/supplies to the Government (see FAR 52.246-1 Contractor Inspection Requirements). The Contractor shall develop, implement, and maintain a Quality Control Program (QCP) to ensure all work described in this contract is performed at or above the standard defined in the Performance Requirements Summary (PRS).\nQuality Control Program. The Contractor shall develop, implement, and maintain an effective Quality Control System, a written Quality Control Plan (QCP). The QCP shall implement standardized procedures and methodologies for monitoring and documenting contract performance to meet all contract requirements. The Contractors QCP shall contain a systematic approach to monitor operations to ensure acceptable services, supplies, and products described in the contract are performed at or above the standards defined in the PWS and Performance Requirements Summary (PRS).\nThe Contractor shall submit their QC Plan no later than (NLT) 10 days after contract award and within five (5) days of any proposed changes. The QCP shall be submitted by the contractor to the Contracting Officer (CO) and Contracting Officer Representative (COR) if it was not already furnished as part of the initial proposal/award package. QCP shall be submitted to the CO and COR within 5 working days when changes are made thereafter. After acceptance of the QC Plan, the contractor shall receive the Contracting Officer s approval in writing of any proposed change to their QC system. The Contractor s QCP shall be incorporated into and become part of this contract after the CO/COR has accepted the plan. Proposed changes made after CO/COR acceptance shall be submitted in writing through the COR to the CO for review and approval before implementing any revision. The Contractor s QCP shall be maintained throughout the contract's life and shall include the Contractor s procedures to routinely evaluate the plan's effectiveness to ensure the Contractor is meeting the performance standards and requirements of the contract.\nContractor s organizational and management structure, titles, responsibilities, and qualifications, work, and quality control verification. A comprehensive program to plan and deliver quality services/supplies described in the contract, prioritize services, and concentrate on the most essential services identified in the Performance Requirements Summary (PRS).\nDescribe a method, acceptable to the Government, of identifying deficiencies in the quality of service performed under the contract before the level of performance becomes unacceptable. Describe a method for preventing and addressing processes for corrective actions without dependence upon Government direction. Contain specific quality control techniques for contract services or supplies identified in the PRS.\nAn established inspection system covering all services required by the contract. The plan shall specify areas to be inspected on both a scheduled and unscheduled basis, as well as the title of the individual who will do the inspection. Maintain a system to examine their subcontractor services and products to ensure compliance with contract requirements and applicable laws and regulations. Specify tasks or areas to be inspected on a scheduled or unscheduled basis, and how inspections will be conducted. The contractor shall provide a current list of all titled positions, the names of the incumbents who will perform the inspections, and the percentage of the work that will be inspected regularly.\nThe contractor shall keep records of all inspection files conducted by the contractor and the necessary corrective action taken. The contractor shall maintain documentation of all contractor quality control inspections and corrective actions throughout the term of this contract.\nThe QCP shall have a customer comment processing system to correct Contracting Officers Representative (COR) validated comments received via email. The system should be designed to provide feedback to the Government based on customer contact, investigation of derogatory comments, rebuttal to derogatory comments, or corrective action(s).\nNon-Conformance Report (NCR). When the Contractor's performance is unsatisfactory, a Contract Discrepancy Report (CDR) will be issued. The Contractor shall reply in writing within five (5) workdays from the date of receipt of the CDR, giving the reasons for the unsatisfactory performance, corrective action taken, and procedures to prevent recurrence.\nQuality Assurance: The COR will evaluate the Contractor s performance under this contract in accordance with the Quality Assurance Surveillance Plan (QASP). This plan is primarily focused on what the COR must do to ensure that the Contractor has performed in accordance with the performance standards. It defines how the performance standards will be applied, the frequency of surveillance, and the minimum acceptable defect rate(s). When an observation indicates defective performance, the COR will require the Contractor or designated on-site representative to initial the observation to acknowledge the defective performance. The acknowledgement of the observation does not necessarily constitute Contractor concurrence with the observation, only that the Contractor has been made aware of the defective performance. Clauses of FAR 52.246-1, Inspection of Supplies -Fixed Price and FAR 52.246-4, Inspection of Services -Fixed-Price shall be followed as an assisting means of determination for the quality of worked performed.\nContractor shall submit field service reports to the COR, including:\nArrival/departure times\nEquipment serviced (type, model, serial)\nMaintenance details\nParts replaced\nDuration of Service\n\nThe contractor shall provide monthly audit reports of man-hours utilized for the month and current equipment fund balances. The report must include an itemized list of equipment purchases. It is due on the 15th of the month for the prior month of service.\n7. System Modifications\nAny proposed system changes must be submitted in writing to the COR. Approved modifications must be reflected in updated operations and maintenance documentation.\n8. Qualifications\nService personnel must:\nHold technician certifications with Lenel, Milestone, and Zenitel Stentfon\nMicrosoft Certified: Windows Server Hybrid Administrator Associate.\nUnderstand VA policies for safety, emergency response, and facility procedures.\nProvide qualifications and job descriptions before service initiation.\n9. Place of Performance\nStratton VA Medical Center\n113 Holland Avenue\nAlbany, NY 12208\n\nSPECIAL NOTE: Albany Stratton s Integrated Security System and all of its components, including servers, are not accessible via REMOTE connections of any type. ALL services MUST be performed ONSITE.\n10. Period of Performance\nThe performance period must be 12 months, with four 12-month optional periods of performance.\nBase Year + Four (4) optional one-year renewals at government discretion\nThere are eleven (11) Federal holidays set by law (USC Title 5 Section 6103) that VA follows:\nUnder current definitions, five (5) are set by date:\nNew Year s Day January 1,\nJuneteenth June 19,\nIndependence Day July 4,\nVeterans Day November 11,\nChristmas Day December 25,\n\nIf any of the above dates falls on a Saturday, then Friday must be observed as a holiday. Similarly, if any of the above dates falls on a Sunday, then Monday must be observed as a holiday.\nThe other six (6) are set by a day of the week and month:\nMartin Luther King's Birthday Third Monday in January\nWashington's Birthday Third Monday in February\nMemorial Day Last Monday in May\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nThanksgiving Fourth Thursday in November\n11. System Inventory\nAttachment B\n12. Software Licenses\nAttachment A\n\nAttachment A\n\nSystem Software Required to be maintained:\nAnnual Licenses to be supplied:\n\nMicro Technology Lynx:\nStandard 7.24.09.1\nAlbany VA Medical Center LYNX-702283\nExpiration Date: 7/1/2026\n10,000 Lynx Guide Server Seats\n4000 Lynx KeyPro Seats\n10 Lynx Messenger Pro seats\n10 LynxIcon Pro seats\n\nMilestone Care Plus Service Agreement\nXProtect Expert 2023 R2\nExpiration Date: 1/30/2026\nSLC: M01-C02-232-01-6C4267\nDevice licenses 261 used out of 304\n\nLenel S2 OnGuard Enterprise Software Support Agreement\nExpiration Date: 9/30/2025\nProduct version 8.1.639.468\nDongle ID 86170\n\nTraka Annual Software License\nTrakaWeb ver 4.1.3\nSoftware Expiration Date: 1/9/2026\n3 Key Cabinets\nCustomer Code: 12280\n\nZenitel AlphaCom Core\n17 Stations in license 8 in use\n\nAttachment B 1\nPerformance Requirements Summary (PRS)\nSystem Hardware\nAccess Control\nLenel OnguardS2\n1 Server Dell EMC PowerEdge R740\n5 Workstations (Client Computers for Alarm Monitoring and Administration)\n12 Lenel Advanced Dual Reader Controller Board LNL-X4420\n10 Lenel-3300 Intelligent System Controller (old Series 1 and 2)\n1 Lenel x3300 Intelligent System Controller (series 3)\n6 Lenel x2220 Intelligent System Controller (series 3)\n68 Lenel LNL-1300 Single Reader Interface Module\n98 Lenel LNL-1320 Dual Reader Interface Module\n87 Lenel 2020 Magnetic Stripe readers\n162 pivCLASS RK40-H Weigand PIV card readers\n\nVideo Surveillance\n3 Husky IVO 1800R Video Recording Servers- 288TB each\n277 Cameras 1 out of service\nWisenet PNM-9084RQZ1\n62\nWisenet PNM-7082RVD\n2\nAxis P3346\n58\nAxis P3225-LVE Mk II\n2\nWisenet PNM-7002VD\n47\nAxis Q1615 MK ii\n1\nWisenet XNV-C6083R\n47\nAxis P3715-PLVE\n1\nWisenet XNP-6400\n12\nAxis P3215-V\n1\nAxis M5525-E-PTZ\n7\nAxis Q6042-E PTZ\n1\nAxis Q3617\n6\nAxis Q1614\n1\nAxis P3364-L\n6\nAxis Q6044-E\n1\nAxis P3717-PLE\n4\nAxis P1377\n1\nWisenet QND-8010R\n3\nAxis P1378-LE\n1\nAxis P3245-V\n3\nAxis P3367\n1\nAxis Q6075-E PTZ\n3\nAxis P3727-PLE\n1\nAxis M3025\n2\nAxis P5635-E-Mk ii\n1\nAxis M3066-V\n2\n\nAttachment B 2\nTraka Key Control System\nDatabase stored on Lenel Server as SQL Table\nFront End Running on Dell Precision Tower 5510\nClients run on Workstations shared with Lenel, 5 Workstations\n1 60- Position Electronic Key Cabinet\n1 120- Position Electronic Key Cabinet\n1 40- Position Electronic Key Cabinet\n\nZenitel AlphaCom Intercom System\nAlphaCom XE1 Audio Server with HD Voice\nWeb Client AlphaWeb XE\n5 Intercoms\n3 Desk Stations\n\nLynx Keyboard Duress Alarm System\nLynx Server is maintained on a VA Virtual Server\nLynx Clients installed on all Albany VAMC computers\n\nBalance\nTotal\nUsed\nBalance\nLynxGuide Server Seats\n10000\n5226\n4774\nLynxKeyPro\n4000\n2606\n1394\nLynxMessengerPro\n10\n0\n10\nLynxIconPro\n10\n0\n10","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24225Q1030","place_of_performance":{"zip":"12208-3410","city":{"code":"1000","name":"Albany"},"state":{"code":"NY","name":"New York"},"country":{"code":"USA","name":"UNITED STATES"},"street2":"Samuel S. Stratton VA Medical Center 113 Holland Avenue"},"product_service_code":"J063"}],"due_at":"2025-09-04T19:00:00Z","due_date":"2025-09-04","closes_at":"2025-09-04T19:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36001","county_name":"Albany County","city":"3601000","city_name":"Albany","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-02T02:40:37.642339Z","principal_notice_id":"67ffd9fcca6d4088aa64fe22d9b48def","description":{"text":"Performance Work Statement (PWS)\nSecurity Systems Preventive Maintenance, Repair Service, and Support\nAlbany Stratton VA Medical Center\nAlbany, New York\n1. Background\nThe Albany VA Medical Center seeks to procure a contract for software, technical services, maintenance, repairs, and upgrades for its integrated security infrastructure. This includes the Milestone Video Surveillance System (VASS), Lenel Physical Access Control System (PACS), Lynx Keyboard Alarm System, Traka Key Control System, and the Zenitel AlphaCom Intercom system.\nThe purpose of this contract is to:\nThis contract ensures the reliable operation and timely service of the VAMC-Albany Security Systems Infrastructure, explicitly addressing the upkeep and repair of security, surveillance, access control, and intercom devices.\n2. Scope of Work\nThe Contractor must support and maintain the existing integrated security infrastructure, which includes the Milestone Video Surveillance System (VASS), Lenel Physical Access Control System (PACS), Lynx Keyboard Alarm System, Traka Key Control System, and the Zenitel AlphaCom Intercom system installed at the Albany Stratton Medical Center.\nThe contractor must manage a service request response system for maintenance requests. Before conducting any work at the Albany Office, the contractor must employ maintenance personnel who are trained and certified in the use and operation of all security, access control, and video surveillance equipment located within the facility and listed in Appendix B.\nThe contractor must provide preventative maintenance and repairs supporting the Albany VAMC Medical Center's integrated security infrastructure at 113 Holland Avenue, Albany, New York. The contractor must provide all necessary resources to maintain and repair the existing systems, including labor, supervision, equipment, tools, materials, supplies, travel, and transportation required for system maintenance and repairs. Repair and replacement parts must be included. Systems functionality must be achieved upon completion of the first service call. Functionality is defined as a working system as designed, but may be accomplished with any part available to the Technician at the time of service. Only when repair is not possible during a service call can a loaner (or equal) part be used to regain system functionality.\n\n3. Service Requirements\na. Standard Service Calls:\n- Acknowledge service calls within 4 hours.\n- Respond and restore service within 2 days.\n- Regular business hours: Mon Fri, 8:00 am 5:00 pm.\n\nb. Emergency Service Calls:\n- Acknowledge within 4 hours.\n- Respond and restore service within 8 hours.\n- Applicable 7 days/week.\n\nc. Preventive Maintenance:\n- Quarterly preventive maintenance is performed during weekday business hours.\n- Must include system inspection, cleaning, adjustment, battery testing/replacement, hard drive checks, firmware/software updates, and final test runs.\n\nDue to the contract's required response and repair times, vendors must utilize technicians who dispatch from a work site or base location with available resources and equipment within a 60-mile radius of the Albany Stratton VAMC.\n\nWork performed by Contractor personnel under the terms of this contract shall not interfere with regularly scheduled government operational activities.\n4. Specific Tasks and Deliverables\nThe contractor must obtain all necessary equipment, parts, and manufacturer's specifications and create as-built drawings to manage the facilities' existing integrated security infrastructure, maintenance, and repair as required. See the equipment list in Appendix B.\nThe contractor must provide the Government COR with the Contractor s technical support number and one Point of Contact (POC) for service and account representation. The POC must provide customer service to VA for all questions or concerns related to this requirement.\nThe contractor must perform maintenance services and repairs Monday through Friday during regular business hours, 8:30 A.M. through 5:00 P.M. EST, and must commence no later than 1:00 P.M. EST.\nThe Contractor must advise the COR of potential delays in completing any aspects of the repair and provide recommendations on actions necessary to keep the task on schedule.\nThe Contractor must perform quarterly preventive maintenance on all listed systems during the contract. This must include manual inspection and testing of all systems, with inspection and testing reports regularly updated in accordance with manufacturer recommendations. The maintenance must also include site visits to modify or replace any system component. The contractor must provide the COR with a site visit report listing all updates and corrective actions. The contractor must verify the operation of the systems with the COR upon completion of work.\nThe contractor must repair or replace any equipment (listed in Appendix B) as necessary to ensure it remains fully functional and operates according to the manufacturer s specifications. To maintain proper operation, the contractor must ensure all system equipment is configured correctly.\nFurnish all labor, tools, certifications, safety gear, software, replacement parts, and plenum-rated cabling.\nThe Contractor must maintain an on-site inventory of replacement parts suitable for the security equipment. Replacement parts are included at no additional cost to the Government. All replaced equipment is the property of the VA and must be provided to the Contracting Officer s Representative (COR) when deemed necessary.\nOpen a Vendor Credentialing Service (VCS) account and comply with VA background check and access procedures.\nPerform monthly preventive maintenance (PM), including maintaining and creating full backups of the SQL server databases, updating and maintaining Windows Server software, and installing security patches and updates to the security system software and hardware.\nProvide necessary software and hardware upgrades, as well as reprogramming, to maintain compliance with the VA Technical Reference Model.\nMaintain support service agreements and yearly device licensing for the following, as listed in Appendix A\nLenel S2 Software Support Agreement and device licensing\nMilestone Software Support Agreement and device licensing\nTraka Yearly Software License for three cabinets\nLynx Software License\n\nThe contractor must provide technicians with up-to-date certifications: Lenel LCA, LCP, LCE, LCDA, Milestone, Zenitel AlphaCom.\nProvide 600 on-site labor hours annually, including at least 40 PM hours each quarter. Any unused hours will be credited back to the Government as funds available for purchasing security equipment. This audit and credit will occur monthly.\nThe contract must include provisions for the new installation of PACS or VASS.\na. New access controls for three doors are installed per year.\nTypical installation as an example:\nSolid wood door, BEST cylindrical or mortise electrified lockset, pivCLASS reader, LNL-1320 Series 3 Dual Reader Interface Module, cross-drill door, 24V Power supply cabinet with battery backup, door position sensor, request to exit, 200 feet of composite cabling.\nb. New camera installation for three locations per year.\nTypical VASS installation as an example:\nHanwha QNV-7022R 4MP Network IR Vandal-Resistant Camera, with Cat6 wiring typically under 100 feet to a network switch.\nProvide an equipment fund paid for by the contract to include frequently used items such as HID iCLASS Proximity Cards, HID iCLASS Proximity FOBS, and HID FARGO Ribbon Consumables for the HID FARGO DTC4500e printer.\nTypical annual equipment failure rates:\nCameras: 4\nPOE Injectors: 4\nPOE Surge protectors: 5\nPIV Card Readers: 6\nDoor Locksets: 4\n24V Power Supplies: 5\nDoor Relays: 6\nWall/Computer monitors: 2\n5. Government-Furnished Resources\nNone\n6. Reporting Requirements\nQuality Control: Quality Control is the responsibility of the Contractor. The Contractor is responsible for delivering quality services/supplies to the Government (see FAR 52.246-1 Contractor Inspection Requirements). The Contractor shall develop, implement, and maintain a Quality Control Program (QCP) to ensure all work described in this contract is performed at or above the standard defined in the Performance Requirements Summary (PRS).\nQuality Control Program. The Contractor shall develop, implement, and maintain an effective Quality Control System, a written Quality Control Plan (QCP). The QCP shall implement standardized procedures and methodologies for monitoring and documenting contract performance to meet all contract requirements. The Contractors QCP shall contain a systematic approach to monitor operations to ensure acceptable services, supplies, and products described in the contract are performed at or above the standards defined in the PWS and Performance Requirements Summary (PRS).\nThe Contractor shall submit their QC Plan no later than (NLT) 10 days after contract award and within five (5) days of any proposed changes. The QCP shall be submitted by the contractor to the Contracting Officer (CO) and Contracting Officer Representative (COR) if it was not already furnished as part of the initial proposal/award package. QCP shall be submitted to the CO and COR within 5 working days when changes are made thereafter. After acceptance of the QC Plan, the contractor shall receive the Contracting Officer s approval in writing of any proposed change to their QC system. The Contractor s QCP shall be incorporated into and become part of this contract after the CO/COR has accepted the plan. Proposed changes made after CO/COR acceptance shall be submitted in writing through the COR to the CO for review and approval before implementing any revision. The Contractor s QCP shall be maintained throughout the contract's life and shall include the Contractor s procedures to routinely evaluate the plan's effectiveness to ensure the Contractor is meeting the performance standards and requirements of the contract.\nContractor s organizational and management structure, titles, responsibilities, and qualifications, work, and quality control verification. A comprehensive program to plan and deliver quality services/supplies described in the contract, prioritize services, and concentrate on the most essential services identified in the Performance Requirements Summary (PRS).\nDescribe a method, acceptable to the Government, of identifying deficiencies in the quality of service performed under the contract before the level of performance becomes unacceptable. Describe a method for preventing and addressing processes for corrective actions without dependence upon Government direction. Contain specific quality control techniques for contract services or supplies identified in the PRS.\nAn established inspection system covering all services required by the contract. The plan shall specify areas to be inspected on both a scheduled and unscheduled basis, as well as the title of the individual who will do the inspection. Maintain a system to examine their subcontractor services and products to ensure compliance with contract requirements and applicable laws and regulations. Specify tasks or areas to be inspected on a scheduled or unscheduled basis, and how inspections will be conducted. The contractor shall provide a current list of all titled positions, the names of the incumbents who will perform the inspections, and the percentage of the work that will be inspected regularly.\nThe contractor shall keep records of all inspection files conducted by the contractor and the necessary corrective action taken. The contractor shall maintain documentation of all contractor quality control inspections and corrective actions throughout the term of this contract.\nThe QCP shall have a customer comment processing system to correct Contracting Officers Representative (COR) validated comments received via email. The system should be designed to provide feedback to the Government based on customer contact, investigation of derogatory comments, rebuttal to derogatory comments, or corrective action(s).\nNon-Conformance Report (NCR). When the Contractor's performance is unsatisfactory, a Contract Discrepancy Report (CDR) will be issued. The Contractor shall reply in writing within five (5) workdays from the date of receipt of the CDR, giving the reasons for the unsatisfactory performance, corrective action taken, and procedures to prevent recurrence.\nQuality Assurance: The COR will evaluate the Contractor s performance under this contract in accordance with the Quality Assurance Surveillance Plan (QASP). This plan is primarily focused on what the COR must do to ensure that the Contractor has performed in accordance with the performance standards. It defines how the performance standards will be applied, the frequency of surveillance, and the minimum acceptable defect rate(s). When an observation indicates defective performance, the COR will require the Contractor or designated on-site representative to initial the observation to acknowledge the defective performance. The acknowledgement of the observation does not necessarily constitute Contractor concurrence with the observation, only that the Contractor has been made aware of the defective performance. Clauses of FAR 52.246-1, Inspection of Supplies -Fixed Price and FAR 52.246-4, Inspection of Services -Fixed-Price shall be followed as an assisting means of determination for the quality of worked performed.\nContractor shall submit field service reports to the COR, including:\nArrival/departure times\nEquipment serviced (type, model, serial)\nMaintenance details\nParts replaced\nDuration of Service\n\nThe contractor shall provide monthly audit reports of man-hours utilized for the month and current equipment fund balances. The report must include an itemized list of equipment purchases. It is due on the 15th of the month for the prior month of service.\n7. System Modifications\nAny proposed system changes must be submitted in writing to the COR. Approved modifications must be reflected in updated operations and maintenance documentation.\n8. Qualifications\nService personnel must:\nHold technician certifications with Lenel, Milestone, and Zenitel Stentfon\nMicrosoft Certified: Windows Server Hybrid Administrator Associate.\nUnderstand VA policies for safety, emergency response, and facility procedures.\nProvide qualifications and job descriptions before service initiation.\n9. Place of Performance\nStratton VA Medical Center\n113 Holland Avenue\nAlbany, NY 12208\n\nSPECIAL NOTE: Albany Stratton s Integrated Security System and all of its components, including servers, are not accessible via REMOTE connections of any type. ALL services MUST be performed ONSITE.\n10. Period of Performance\nThe performance period must be 12 months, with four 12-month optional periods of performance.\nBase Year + Four (4) optional one-year renewals at government discretion\nThere are eleven (11) Federal holidays set by law (USC Title 5 Section 6103) that VA follows:\nUnder current definitions, five (5) are set by date:\nNew Year s Day January 1,\nJuneteenth June 19,\nIndependence Day July 4,\nVeterans Day November 11,\nChristmas Day December 25,\n\nIf any of the above dates falls on a Saturday, then Friday must be observed as a holiday. Similarly, if any of the above dates falls on a Sunday, then Monday must be observed as a holiday.\nThe other six (6) are set by a day of the week and month:\nMartin Luther King's Birthday Third Monday in January\nWashington's Birthday Third Monday in February\nMemorial Day Last Monday in May\nLabor Day First Monday in September\nColumbus Day Second Monday in October\nThanksgiving Fourth Thursday in November\n11. System Inventory\nAttachment B\n12. Software Licenses\nAttachment A\n\nAttachment A\n\nSystem Software Required to be maintained:\nAnnual Licenses to be supplied:\n\nMicro Technology Lynx:\nStandard 7.24.09.1\nAlbany VA Medical Center LYNX-702283\nExpiration Date: 7/1/2026\n10,000 Lynx Guide Server Seats\n4000 Lynx KeyPro Seats\n10 Lynx Messenger Pro seats\n10 LynxIcon Pro seats\n\nMilestone Care Plus Service Agreement\nXProtect Expert 2023 R2\nExpiration Date: 1/30/2026\nSLC: M01-C02-232-01-6C4267\nDevice licenses 261 used out of 304\n\nLenel S2 OnGuard Enterprise Software Support Agreement\nExpiration Date: 9/30/2025\nProduct version 8.1.639.468\nDongle ID 86170\n\nTraka Annual Software License\nTrakaWeb ver 4.1.3\nSoftware Expiration Date: 1/9/2026\n3 Key Cabinets\nCustomer Code: 12280\n\nZenitel AlphaCom Core\n17 Stations in license 8 in use\n\nAttachment B 1\nPerformance Requirements Summary (PRS)\nSystem Hardware\nAccess Control\nLenel OnguardS2\n1 Server Dell EMC PowerEdge R740\n5 Workstations (Client Computers for Alarm Monitoring and Administration)\n12 Lenel Advanced Dual Reader Controller Board LNL-X4420\n10 Lenel-3300 Intelligent System Controller (old Series 1 and 2)\n1 Lenel x3300 Intelligent System Controller (series 3)\n6 Lenel x2220 Intelligent System Controller (series 3)\n68 Lenel LNL-1300 Single Reader Interface Module\n98 Lenel LNL-1320 Dual Reader Interface Module\n87 Lenel 2020 Magnetic Stripe readers\n162 pivCLASS RK40-H Weigand PIV card readers\n\nVideo Surveillance\n3 Husky IVO 1800R Video Recording Servers- 288TB each\n277 Cameras 1 out of service\nWisenet PNM-9084RQZ1\n62\nWisenet PNM-7082RVD\n2\nAxis P3346\n58\nAxis P3225-LVE Mk II\n2\nWisenet PNM-7002VD\n47\nAxis Q1615 MK ii\n1\nWisenet XNV-C6083R\n47\nAxis P3715-PLVE\n1\nWisenet XNP-6400\n12\nAxis P3215-V\n1\nAxis M5525-E-PTZ\n7\nAxis Q6042-E PTZ\n1\nAxis Q3617\n6\nAxis Q1614\n1\nAxis P3364-L\n6\nAxis Q6044-E\n1\nAxis P3717-PLE\n4\nAxis P1377\n1\nWisenet QND-8010R\n3\nAxis P1378-LE\n1\nAxis P3245-V\n3\nAxis P3367\n1\nAxis Q6075-E PTZ\n3\nAxis P3727-PLE\n1\nAxis M3025\n2\nAxis P5635-E-Mk ii\n1\nAxis M3066-V\n2\n\nAttachment B 2\nTraka Key Control System\nDatabase stored on Lenel Server as SQL Table\nFront End Running on Dell Precision Tower 5510\nClients run on Workstations shared with Lenel, 5 Workstations\n1 60- Position Electronic Key Cabinet\n1 120- Position Electronic Key Cabinet\n1 40- Position Electronic Key Cabinet\n\nZenitel AlphaCom Intercom System\nAlphaCom XE1 Audio Server with HD Voice\nWeb Client AlphaWeb XE\n5 Intercoms\n3 Desk Stations\n\nLynx Keyboard Duress Alarm System\nLynx Server is maintained on a VA Virtual Server\nLynx Clients installed on all Albany VAMC computers\n\nBalance\nTotal\nUsed\nBalance\nLynxGuide Server Seats\n10000\n5226\n4774\nLynxKeyPro\n4000\n2606\n1394\nLynxMessengerPro\n10\n0\n10\nLynxIconPro\n10\n0\n10","html":"Performance Work Statement (PWS)\nSecurity Systems Preventive Maintenance, Repair Service, and Support\nAlbany Stratton VA Medical Center\nAlbany, New York\n1. Background\nThe Albany VA Medical Center seeks to procure a contract for software, technical services, maintenance, repairs, and upgrades for its integrated security infrastructure.  This includes the Milestone Video Surveillance System (VASS), Lenel Physical Access Control System (PACS), Lynx Keyboard Alarm System, Traka Key Control System, and the Zenitel AlphaCom Intercom system.\nThe purpose of this contract is to:\nThis contract ensures the reliable operation and timely service of the VAMC-Albany Security Systems Infrastructure, explicitly addressing the upkeep and repair of security, surveillance, access control, and intercom devices.\n2. Scope of Work\nThe Contractor must support and maintain the existing integrated security infrastructure, which includes the Milestone Video Surveillance System (VASS), Lenel Physical Access Control System (PACS), Lynx Keyboard Alarm System, Traka Key Control System, and the Zenitel AlphaCom Intercom system installed at the Albany Stratton Medical Center. \nThe contractor must manage a service request response system for maintenance requests. Before conducting any work at the Albany Office, the contractor must employ maintenance personnel who are trained and certified in the use and operation of all security, access control, and video surveillance equipment located within the facility and listed in Appendix B. \n The contractor must provide preventative maintenance and repairs supporting the Albany VAMC Medical Center's integrated security infrastructure at 113 Holland Avenue, Albany, New York. The contractor must provide all necessary resources to maintain and repair the existing systems, including labor, supervision, equipment, tools, materials, supplies, travel, and transportation required for system maintenance and repairs. Repair and replacement parts must be included. Systems functionality must be achieved upon completion of the first service call. Functionality is defined as a working system as designed, but may be accomplished with any part available to the Technician at the time of service. Only when repair is not possible during a service call can a loaner (or equal) part be used to regain system functionality. \n\n3. Service Requirements\na. Standard Service Calls:\n- Acknowledge service calls within 4 hours.\n- Respond and restore service within 2 days.\n- Regular business hours: Mon Fri, 8:00 am   5:00 pm.\n\nb. Emergency Service Calls:\n- Acknowledge within 4 hours.\n- Respond and restore service within 8 hours.\n- Applicable 7 days/week.\n\nc. Preventive Maintenance:\n- Quarterly preventive maintenance is performed during weekday business hours.\n- Must include system inspection, cleaning, adjustment, battery testing/replacement, hard drive checks, firmware/software updates, and final test runs.\n\nDue to the contract's required response and repair times, vendors must utilize technicians who dispatch from a work site or base location with available resources and equipment within a 60-mile radius of the Albany Stratton VAMC. \n\nWork performed by Contractor personnel under the terms of this contract shall not interfere with regularly scheduled government operational activities. \n4. Specific Tasks and Deliverables \nThe contractor must obtain all necessary equipment, parts, and manufacturer's specifications and create as-built drawings to manage the facilities' existing integrated security infrastructure, maintenance, and repair as required. See the equipment list in Appendix B. \nThe contractor must provide the Government COR with the Contractor s technical support number and one Point of Contact (POC) for service and account representation. The POC must provide customer service to VA for all questions or concerns related to this requirement. \nThe contractor must perform maintenance services and repairs Monday through Friday during regular business hours, 8:30 A.M. through 5:00 P.M. EST, and must commence no later than 1:00 P.M. EST. \nThe Contractor must advise the COR of potential delays in completing any aspects of the repair and provide recommendations on actions necessary to keep the task on schedule. \nThe Contractor must perform quarterly preventive maintenance on all listed systems during the contract. This must include manual inspection and testing of all systems, with inspection and testing reports regularly updated in accordance with manufacturer recommendations. The maintenance must also include site visits to modify or replace any system component. The contractor must provide the COR with a site visit report listing all updates and corrective actions. The contractor must verify the operation of the systems with the COR upon completion of work. \nThe contractor must repair or replace any equipment (listed in Appendix B) as necessary to ensure it remains fully functional and operates according to the manufacturer s specifications. To maintain proper operation, the contractor must ensure all system equipment is configured correctly.\nFurnish all labor, tools, certifications, safety gear, software, replacement parts, and plenum-rated cabling.\nThe Contractor must maintain an on-site inventory of replacement parts suitable for the security equipment. Replacement parts are included at no additional cost to the Government. All replaced equipment is the property of the VA and must be provided to the Contracting Officer s Representative (COR) when deemed necessary. \nOpen a Vendor Credentialing Service (VCS) account and comply with VA background check and access procedures.\nPerform monthly preventive maintenance (PM), including maintaining and creating full backups of the SQL server databases, updating and maintaining Windows Server software, and installing security patches and updates to the security system software and hardware. \nProvide necessary software and hardware upgrades, as well as reprogramming, to maintain compliance with the VA Technical Reference Model.   \nMaintain support service agreements and yearly device licensing for the following, as listed in Appendix A\n Lenel S2   Software Support Agreement and device licensing\n Milestone   Software Support Agreement and device licensing\n Traka Yearly Software License for three cabinets\nLynx Software License\n\nThe contractor must provide technicians with up-to-date certifications: Lenel LCA, LCP, LCE, LCDA, Milestone, Zenitel AlphaCom.\nProvide 600 on-site labor hours annually, including at least 40 PM hours each quarter. Any unused hours will be credited back to the Government as funds available for purchasing security equipment. This audit and credit will occur monthly. \nThe contract must include provisions for the new installation of PACS or VASS.\n a. New access controls for three doors are installed per year.\nTypical installation as an example: \nSolid wood door, BEST cylindrical or mortise electrified lockset, pivCLASS reader, LNL-1320 Series 3 Dual Reader Interface Module, cross-drill door, 24V Power supply cabinet with battery backup, door position sensor, request to exit, 200 feet of composite cabling. \n b. New camera installation for three locations per year.\nTypical VASS installation as an example:\nHanwha QNV-7022R 4MP Network IR Vandal-Resistant Camera, with Cat6 wiring typically under 100 feet to a network switch. \nProvide an equipment fund paid for by the contract to include frequently used items such as HID iCLASS Proximity Cards, HID iCLASS Proximity FOBS, and HID FARGO Ribbon Consumables for the HID FARGO DTC4500e printer.  \nTypical annual equipment failure rates:\nCameras: 4\nPOE Injectors: 4\nPOE Surge protectors: 5\nPIV Card Readers: 6\nDoor Locksets: 4\n24V Power Supplies: 5\nDoor Relays: 6\nWall/Computer monitors: 2\n5. Government-Furnished Resources\nNone\n6. Reporting Requirements\nQuality Control:  Quality Control is the responsibility of the Contractor. The Contractor is responsible for delivering quality services/supplies to the Government (see FAR 52.246-1 Contractor Inspection Requirements). The Contractor shall develop, implement, and maintain a Quality Control Program (QCP) to ensure all work described in this contract is performed at or above the standard defined in the Performance Requirements Summary (PRS).  \nQuality Control Program. The Contractor shall develop, implement, and maintain an effective Quality Control System, a written Quality Control Plan (QCP). The QCP shall implement standardized procedures and methodologies for monitoring and documenting contract performance to meet all contract requirements. The Contractors  QCP shall contain a systematic approach to monitor operations to ensure acceptable services, supplies, and products described in the contract are performed at or above the standards defined in the PWS and Performance Requirements Summary (PRS).\nThe Contractor shall submit their QC Plan no later than (NLT) 10 days after contract award and within five (5) days of any proposed changes. The QCP shall be submitted by the contractor to the Contracting Officer (CO) and Contracting Officer Representative (COR) if it was not already furnished as part of the initial proposal/award package.  QCP shall be submitted to the CO and COR within 5 working days when changes are made thereafter. After acceptance of the QC Plan, the contractor shall receive the Contracting Officer s approval in writing of any proposed change to their QC system. The Contractor s QCP shall be incorporated into and become part of this contract after the CO/COR has accepted the plan. Proposed changes made after CO/COR acceptance shall be submitted in writing through the COR to the CO for review and approval before implementing any revision.  The Contractor s QCP shall be maintained throughout the contract's life and shall include the Contractor s procedures to routinely evaluate the plan's effectiveness to ensure the Contractor is meeting the performance standards and requirements of the contract.  \nContractor s organizational and management structure, titles, responsibilities, and qualifications, work, and quality control verification. A comprehensive program to plan and deliver quality services/supplies described in the contract, prioritize services, and concentrate on the most essential services identified in the Performance Requirements Summary (PRS).\nDescribe a method, acceptable to the Government, of identifying deficiencies in the quality of service performed under the contract before the level of performance becomes unacceptable.  Describe a method for preventing and addressing processes for corrective actions without dependence upon Government direction.  Contain specific quality control techniques for contract services or supplies identified in the PRS.\nAn established inspection system covering all services required by the contract.  The plan shall specify areas to be inspected on both a scheduled and unscheduled basis, as well as the title of the individual who will do the inspection.  Maintain a system to examine their subcontractor services and products to ensure compliance with contract requirements and applicable laws and regulations. Specify tasks or areas to be inspected on a scheduled or unscheduled basis, and how inspections will be conducted. The contractor shall provide a current list of all titled positions, the names of the incumbents who will perform the inspections, and the percentage of the work that will be inspected regularly.\nThe contractor shall keep records of all inspection files conducted by the contractor and the necessary corrective action taken. The contractor shall maintain documentation of all contractor quality control inspections and corrective actions throughout the term of this contract.\nThe QCP shall have a customer comment processing system to correct Contracting Officers Representative (COR) validated comments received via email. The system should be designed to provide feedback to the Government based on customer contact, investigation of derogatory comments, rebuttal to derogatory comments, or corrective action(s).  \nNon-Conformance Report (NCR).  When the Contractor's performance is unsatisfactory, a Contract Discrepancy Report (CDR) will be issued.  The Contractor shall reply in writing within five (5) workdays from the date of receipt of the CDR, giving the reasons for the unsatisfactory performance, corrective action taken, and procedures to prevent recurrence.\nQuality Assurance:  The COR will evaluate the Contractor s performance under this contract in accordance with the Quality Assurance Surveillance Plan (QASP).  This plan is primarily focused on what the COR must do to ensure that the Contractor has performed in accordance with the performance standards.  It defines how the performance standards will be applied, the frequency of surveillance, and the minimum acceptable defect rate(s). When an observation indicates defective performance, the COR will require the Contractor or designated on-site representative to initial the observation to acknowledge the defective performance.  The acknowledgement of the observation does not necessarily constitute Contractor concurrence with the observation, only that the Contractor has been made aware of the defective performance. Clauses of FAR 52.246-1, Inspection of Supplies -Fixed Price and FAR 52.246-4, Inspection of Services -Fixed-Price shall be followed as an assisting means of determination for the quality of worked performed.\nContractor shall submit field service reports to the COR, including:\nArrival/departure times\nEquipment serviced (type, model, serial)\nMaintenance details\nParts replaced\nDuration of Service\n\nThe contractor shall provide monthly audit reports of man-hours utilized for the month and current equipment fund balances. The report must include an itemized list of equipment purchases. It is due on the 15th of the month for the prior month of service.\n7. System Modifications\nAny proposed system changes must be submitted in writing to the COR. Approved modifications must be reflected in updated operations and maintenance documentation.\n8. Qualifications\nService personnel must:\nHold technician certifications with Lenel, Milestone, and Zenitel Stentfon\nMicrosoft Certified: Windows Server Hybrid Administrator Associate. \nUnderstand VA policies for safety, emergency response, and facility procedures.\nProvide qualifications and job descriptions before service initiation.\n9. Place of Performance\nStratton VA Medical Center\n113 Holland Avenue\nAlbany, NY 12208\n\nSPECIAL NOTE: Albany Stratton s Integrated Security System and all of its components, including servers, are not accessible via REMOTE connections of any type. ALL services MUST be performed ONSITE.\n10. Period of Performance\nThe performance period must be 12 months, with four 12-month optional periods of performance.\nBase Year + Four (4) optional one-year renewals at government discretion\nThere are eleven (11) Federal holidays set by law (USC Title 5 Section 6103) that VA follows: \nUnder current definitions, five (5) are set by date:\nNew Year s Day January 1, \nJuneteenth  June 19,\nIndependence Day July 4,\nVeterans Day  November 11, \nChristmas Day  December 25,\n\n If any of the above dates falls on a Saturday, then Friday must be observed as a holiday. Similarly, if any of the above dates falls on a Sunday, then Monday must be observed as a holiday.\n The other six (6) are set by a day of the week and month:\n Martin Luther King's Birthday  Third Monday in January \nWashington's Birthday   Third Monday in February\nMemorial Day    Last Monday in May\nLabor Day    First Monday in September\nColumbus Day    Second Monday in October\nThanksgiving     Fourth Thursday in November\n11. System Inventory\nAttachment B\n12. Software Licenses\nAttachment A\n\n\n\n\n\n\n\nAttachment A\n\nSystem Software Required to be maintained:\nAnnual Licenses to be supplied: \n\nMicro Technology Lynx: \nStandard 7.24.09.1\nAlbany VA Medical Center LYNX-702283\nExpiration Date: 7/1/2026\n10,000 Lynx Guide Server Seats\n4000 Lynx KeyPro Seats\n10 Lynx Messenger Pro seats\n10 LynxIcon Pro seats\n\nMilestone Care Plus Service Agreement \nXProtect Expert 2023 R2\nExpiration Date: 1/30/2026\nSLC: M01-C02-232-01-6C4267\nDevice licenses 261 used out of 304\n\nLenel S2 OnGuard Enterprise Software Support Agreement\nExpiration Date: 9/30/2025\nProduct version 8.1.639.468 \nDongle ID 86170\n\nTraka Annual Software License\nTrakaWeb  ver 4.1.3\nSoftware Expiration Date: 1/9/2026\n3 Key Cabinets\nCustomer Code: 12280\n\nZenitel AlphaCom Core\n17 Stations in license   8 in use \n\n\nAttachment B  1\nPerformance Requirements Summary (PRS)\nSystem Hardware\nAccess Control \nLenel OnguardS2\n1 Server Dell EMC PowerEdge R740\n5 Workstations (Client Computers for Alarm Monitoring and Administration)\n12 Lenel Advanced Dual Reader Controller Board LNL-X4420\n10 Lenel-3300 Intelligent System Controller (old Series 1 and 2)\n1 Lenel x3300 Intelligent System Controller (series 3)\n6 Lenel x2220 Intelligent System Controller (series 3)\n68 Lenel LNL-1300 Single Reader Interface Module\n98 Lenel LNL-1320 Dual Reader Interface Module \n87 Lenel 2020 Magnetic Stripe readers \n162 pivCLASS RK40-H Weigand PIV card readers\n\nVideo Surveillance \n3 Husky IVO 1800R Video Recording Servers- 288TB each\n277 Cameras   1 out of service\nWisenet PNM-9084RQZ1\n62\nWisenet PNM-7082RVD\n2\nAxis P3346\n58\nAxis P3225-LVE Mk II\n2\nWisenet PNM-7002VD\n47\nAxis Q1615 MK ii\n1\nWisenet XNV-C6083R\n47\nAxis P3715-PLVE\n1\nWisenet XNP-6400\n12\nAxis P3215-V\n1\nAxis M5525-E-PTZ\n7\nAxis Q6042-E PTZ\n1\nAxis Q3617\n6\nAxis Q1614\n1\nAxis P3364-L\n6\nAxis Q6044-E\n1\nAxis P3717-PLE\n4\nAxis P1377\n1\nWisenet QND-8010R\n3\nAxis P1378-LE\n1\nAxis P3245-V\n3\n Axis P3367\n1\nAxis Q6075-E PTZ\n3\nAxis P3727-PLE\n1\nAxis M3025\n2\nAxis P5635-E-Mk ii\n1\nAxis M3066-V\n2\n\n\n\n\nAttachment B 2\nTraka Key Control System\nDatabase stored on Lenel Server as SQL Table\nFront End Running on Dell Precision Tower 5510\nClients run on Workstations shared with Lenel, 5 Workstations\n1 60- Position Electronic Key Cabinet\n1 120- Position Electronic Key Cabinet\n1 40- Position Electronic Key Cabinet\n\nZenitel AlphaCom Intercom System\nAlphaCom XE1 Audio Server with HD Voice\nWeb Client AlphaWeb XE\n5 Intercoms\n3 Desk Stations\n\nLynx Keyboard Duress Alarm System\nLynx Server is maintained on a VA Virtual Server\nLynx Clients installed on all Albany VAMC computers \n\nBalance\nTotal \nUsed\nBalance\nLynxGuide Server Seats\n10000\n5226\n4774\nLynxKeyPro\n4000\n2606\n1394\nLynxMessengerPro\n10\n0\n10\nLynxIconPro\n10\n0\n10","origin":"detail"},"contacts":[{"name":"Julie Monagan Barnard","role":"primary","email":"julie.monaganbarnard@va.gov","phone":"(607) 590-1325","title":"Contract Specialist"}],"place_of_performance":{"zip":"12208-3410","city":{"code":"1000","name":"Albany"},"state":{"code":"NY","name":"New York"},"country":{"code":"USA","name":"UNITED STATES"},"street2":"Samuel S. Stratton VA Medical Center 113 Holland Avenue"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["561621"],"award":{"awardee":{}},"attachments":[{"resource_id":"2212b472c44340b2a13389590bb3c9bd","name":"va.gov","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-08-28T17:46:19.922Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false}],"awards":[],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0111","latest_notice_id":"53b89ff8f614468b85e0670409cfc7f2","title":"R609--FY27 STENOGRAPHY SERVICES FOR VISN 2","solicitation_number":"36C24227Q0111","notice_type":"o","first_type":"p","first_posted":"2026-11-03","last_posted":"2026-11-23","notices":4,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"561492","psc":"R609","set_aside":"SDVOSBC","state":"NY","county":"36029","county_name":"Erie County","city":"3615000","city_name":"Cheektowaga","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open":[{"key":"36C24227B00091","latest_notice_id":"95528d83dc8d4ea2ab23c54840f9508f","title":"Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC","solicitation_number":"36C24227B0009_1","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-16T15:00:00Z","due_date":"2026-12-16","closes_at":"2026-12-16T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"561621","psc":"Y1DA","set_aside":null,"state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"CE AND UPGRADE FIRE ALARM SYSTEM AT MONTROSE VAMC","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24227B0009","latest_notice_id":"e944982135bd41b08591e4fcdaaaa80c","title":"Y1DA--Project620-22-110 Replace and Upgrade Fire alarm System at Montrose VAMC","solicitation_number":"36C24227B0009","notice_type":"o","first_type":"p","first_posted":"2026-10-28","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-16T15:00:00Z","due_date":"2026-12-16","closes_at":"2026-12-16T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"561621","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"3030127RFQ000001","latest_notice_id":"140cd38f6403477ebe7b5d43a5d18e61","title":"USCG Station Wachapreague Alarm Monitoring Service","solicitation_number":"3030127RFQ000001","notice_type":"o","first_type":"o","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":2,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL30","office_name":"BASE PORTSMOUTH","naics":"561621","psc":"S211","set_aside":"SBA","state":"VA","county":"51001","county_name":"Accomack County","city":"5182320","city_name":"Wachapreague","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-24T06:18:02.791414Z"}],"similar_open_total":26,"indexable":false}