{"canonical":"https://sealedbidder.com/opportunities/36c24225q0508","key":"36C24225Q0508","url":"https://sealedbidder.com/opportunities/36c24225q0508","title":"H999--Air Balancing and Testing Service","solicitation_number":"36C24225Q0508","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-07T14:00:00Z","first_posted":"2025-04-01","last_posted":"2025-04-01","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238220","psc":"H999","set_aside":null,"place_state":"NJ","place_scope":"site","site":null,"place_state_source":"description","place_evidence":"YONS CAMPUS AT 151 KNOLLCROFT ROAD, LYONS, NJ 07939","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"394f83e4c9674597a084841c50c752e3","title":"H999--Air Balancing and Testing Service","solicitation_number":"36C24225Q0508","notice_type":"r","base_type":"r","posted":"2025-04-01","posted_at":"2025-04-01T18:47:49.749Z","due_at":"2025-04-07T14:00:00Z","due_date":"2025-04-07","cancelled":false,"archived":true,"archive_date":"2025-06-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/394f83e4c9674597a084841c50c752e3/view","enriched":true,"history":[{"index":3,"title":"H999--Air Balancing and Testing Service","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-01T18:47:49.749Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"394f83e4c9674597a084841c50c752e3","solicitation_number":"36C24225Q0508"}]}],"latest_notice_id":"394f83e4c9674597a084841c50c752e3","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-04-01","posted_at":"2025-04-01T18:47:49.749Z","created_at":"2025-04-01T18:47:47.546Z","modified_at":"2025-06-06T04:04:31.739Z","response_deadline":{"raw":"2025-04-07T10:00:00-04:00","utc":"2025-04-07T14:00:00Z","date":"2025-04-07","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/394f83e4c9674597a084841c50c752e3/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"H999--Air Balancing and Testing Service","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-06","archive_type":"auto_custom"},"history":[{"index":3,"title":"H999--Air Balancing and Testing Service","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-01T18:47:49.749Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"394f83e4c9674597a084841c50c752e3","solicitation_number":"36C24225Q0508"}],"contacts":[{"name":"Natalie Acevedo","role":"primary","email":"natalie.acevedo@va.gov","phone":"718 584 9000 x4356","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"394f83e4c9674597a084841c50c752e3","lineage_id":"394f83e4c9674597a084841c50c752e3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T08:45:51.923477408Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"a1092b3532cc0c57b35d32bb76c9d526842aba420cbb2847276d09301ebc8eb2","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T08:45:51.923477408Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"This is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law. \n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Bronx, NY for the purpose of collecting information on Air balancing, inspecting and testing services for the New Jersey Health Care System VA Medical Center, Lyons Campus at 151 Knollcroft Road, Lyons, NJ 07939 and East Orange Campus at 385 Tremont Avenue, East Orange, NJ 07018. The VA is seeking to provide for this requirement as of 06/01/2025 to establish a new service. The NAICS code identified for this requirement is 238220 Plumbing, Heating and Air-Conditioning Contractors. The requirement is detailed in the Statement of Work section of this document. \n\n(e) Cursory market research has identified several small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment are encouraged to email a capability statement and full information to Natalie Acevedo at Natalie.Acevedo@va.gov Monday, April 7, 2025 at 10:00 AM EST. \n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category. Contractors shall identify the NAICS code for the services being offered as well as their size status under said NAICS. If contractor is a Service-Disabled Veteran Owned Small Business (SDVOSB), a Veteran Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the package, this may result in the contractor not being considered in the Government s Procurement Strategy. \n\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired services. \n- Contractors shall identify pertinent point of contact for company, contractor EIN number for size standard and socioeconomic verification in SAM and  SBA VetCert, as well as for any intended subcontractors. \n - Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs. \n - Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. \n- Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable. \n\n- Contractors shall include any relevant comments about the Attachment(s) if applicable. \n\nSTATEMENT OF WORK\n\nAIR BALANCING SERVICES\n\n1. BACKGROUND: \nThe Department of Veterans Affairs New Jersey Health Care System is currently seeking for air balancing, adjusting and testing services for Lyons Campus and East Orange Campus. Lyons Campus which was built in the early 1920 s with over 30 major buildings and a few smaller outbuildings sits on 306 acres. East Orange Campus is located on 3 acres with one (1) high-rise building of 13 floors and 12 outbuildings. Contractor shall provide air balancing services for the above two campus at specified months, and quarters as stated in this document and under Equipment List.\n\n2. SCOPE OF WORK: \nContractor shall provide all supervision, labor, materials and equipment necessary to perform air balancing, traverses of air handlers and exhaust systems and provide all related documentation for both campuses.  \n\n3. SPECIFICATIONS:\nContractor shall take CFM (Cubic Feet per Minute) readings from supply and exhaust and make necessary adjustments for the designated areas to be in compliance with room-to-room pressurization design criteria.\n\nContractor will take test readings of each diffuser and grill to include the required Feet per Minute/Cubic Feet per Minute, test results of the Feet Per Minute/. Cubic Feet per Minute and provide instrument calibration reports to comply with requirements in ASHRAE 111, Section 4, Instrumentation. And to provide instrumentation calibration reports to include, instrument type and make, serial number, application, dates of use and dates of calibration.\n\n4. REPORTS: \nContractor shall provide 3 hard copy reports of all readings for both campuses in their TAB (testing, Adjusting and Balancing) report. \n\nAn electronic version of same report shall be sent to the Contracting Officer Representative. Contractor will provide reports in triplicate to include:\n\nA print of the area showing air flow directions and pressures.\nAir exchange per hour for each room or corridor to include room volume, cu , design and actual Cubic Feet per Minute for supply and exhaust air\nCertificate of recalibration for all testing equipment.       \n\nService Reports must be signed by both service provider and Contracting Officer Representative at the completion of each work.\n\nÂ \n5. FREQUENCY: \nContractor shall conduct air balancing, testing and adjusting annually in the 2nd Quarter and semi-annually in the 1st and 3rd Quarters for:\n\n\n1)  East Orange Campus\n 385 Tremont Avenue             \nEast Orange, NJ 07018-109\n\nContractor shall conduct air balancing, testing and adjusting quarterly in the 1st and 3rd quarters for:\n\n2)  Lyons Campus\n 151 Knollcroft Road\n Lyons, NJ 07939\n\n6. REQUIREMENTS:Â  \nContractor shall demonstrate that it is a firm regularly engaged in the field of air balancing services.  \n\nContractor must be certified in Air balancing and must be licensed and insured for this type of work. \n\nContractor shall be certified by either AABC (Associated Air Balance Council) or NEBB (National Environmental Bureau) and provide personnel who are AABC or NEBB certified and qualified to do air balancing.\n\nContractor shall provide certification as required by the Joint Commission on the Accreditation of Healthcare Organizations (JCAHO) with a valid 30-hour safety card for personnel identified to work on this requirement. \n\nContractor shall follow all the Department of Veterans Affair Administrations, State, Federal and OSHA rules and safety regulations.\n\n7. EQUIPMENT LIST:\n\nEAST ORANGE EQUIPMENT LIST: \nÂ \nÂ \nÂ \nAREAS TO BE DONE SEMI-ANNUALLY IN THE 1ST AND 3RD QUARTERS\nÂ \nÂ \n1)  O.R. 2ND FLOOR, C-WING\nÂ \nÂ \nÂ \nAHU 33 C LEVEL\nB. AHU-34 C LEVEL\nC. AHU-35 \nC  LEVEL\nD. EXHAUST #1 1ST FLR C W\nE. EXHAUST #2\nF. EXHAUST 40A\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n2)   SPS 2ND. FLOOR, B-WING\nÂ \nÂ \nÂ \nA. SPS AIR HANDLER 2ND FLR\nB. EXHAUST #1\n6TH FLR ROOF\nEXHAUST #2\n6TH FLR ROOF\nD. EXHAUST 6TH FLR ROOF\nE. EXHAUST #4\nF. EXHAUST #5\nG. EXHAUST #6\nÂ \nÂ 6TH FLR ROOF\nÂ 6TH FLR ROOR\nÂ 6FLR ROOF\nÂ \n3)Â  ENDOSCOPY 2ND. FLOOR, B-WING\nÂ \nÂ \nÂ \nA. ENDOSCOPY AHU 2ND FLOOR B-W\nB. EXHAUST #1\nC. EXHAUST #2\nÂ \nÂ \nÂ 6TH FLR B WING\nÂ 6TH FLR B WING\nÂ \n4)  DENTAL 3RD FLOOR, B-WING - DENTAL AHU\nÂ \nÂ \nÂ \nA. EXHAUST #1\nB.  EXHAUST #2\nÂ \nÂ \nÂ 6TH FLOOR ROOF B SIDE\nÂ 6TH FLOOR ROOF B SIDE\nÂ \nÂ \n5)Â Â Â PHARMACY IV ROOM 8TH FLOOR, A-WING\nÂ \nÂ \nÂ \nA. PHARMACY AHU B LEVEL ROOF\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n6)Â Â HISTOLOGY A-LEVEL, B WING\nÂ \nÂ \nÂ \n A.  AHU-1, A-146\nB.  HOOD EXHAUST 6TH FLOOR ROOF B-WING\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n7)Â Â Â CATH. LAB 9-166\nÂ \nÂ \nÂ \nA. AHU CATH. LAB 9-163\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n8)Â Â Â MORGUE B-LEVEL, C-WING\nÂ \nÂ \nÂ \nA. AHU 10A C LEVEL\nB. TBEF #7\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n9) GAMMA CAMERA 6-CORE\nÂ \nÂ \nÂ \n A. AHU-2 PENTHOUSE\nB. AHU-5 PENTHOUSE\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nAREAS TO BE DONE ANNUALLY IN THE 2ND QUARTER\nÂ \nÂ \n10) FIRST FLOOR LAB 1ST FLOOR B-WING\nÂ \nÂ \nÂ \nA. AHU-17 B-LEVEL ROOF\nB. EXHAUST, 6TH FLOOR ROOF, B-WING ROOF\nÂ \nÂ \nC. HOOD EXHAUST, 6TH FLOOR ROOF, B-WING ROOF\nÂ \nÂ \nÂ \n\n\n\n\n11) FIRST FLOOR RADIOLGY C WING\n\n\n\nAHU A LEVEL ROOF OVER A-215\n\n\n\n\nÂ \nÂ \nÂ \n12) NEW ED A WING\n\n\n\nAHU ROOF OF ED\n2ND FLOOR ROOF A WING\nEXHAUST AUDITORIUM ROOF\n\n\n\n\n\n\n13) SICU/MICU 2ND FLOOR, D-WING\nÂ \nÂ \nÂ \nA. AHU-2D, 2ND FLOOR ROOF\nB. EXHAUST 21, PENTHOUSE\nÂ \nÂ \nC. ISOLATION EXHAUST 3RD FLOOR BUMP-OUT.\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n14) WARD 5B, FLOOR 5 B-WING\nÂ \nÂ \nÂ \nA. AHU-1 PENTHOUSE\nB. AHU-4, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 4 PENTHOUSE\nD. MUSHROOM ON 6B ROOF\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n15) WARD 5-C, FLOOR 5 C-WING\nÂ \nÂ \nÂ \nA. AHU-5C, 6TH FLOOR ROOF C-WING\nB. EXHAUST 1, 6TH FLOOR ROOF C-WING\nÂ \nÂ \nC. EXHAUST 2, 6TH FLOOR ROOF C-WING\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n16) WARD 5D, FLOOR 5, D-WING\nÂ \nÂ \nÂ \nA. AHU-3, PENTHOUSE\nB. AHU-6, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 18 PENTHOUSE\nD. EXHAUST, MUSHROOM ON 6D ROOF\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n17) WARD 6B, FLOOR 6 B-WING\nÂ \nÂ \nÂ \nA. AHU-1, PENTHOUSE\nB. AHU-4, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 10, PENTHOUSE\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n18) WARD 9A, 9TH FLOOR, A-WING\nÂ \nÂ \nÂ \nA. AHU-3, PENTHOUSE\nB. AHU-6, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 23, PENTHOUSE\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n19) WARD 12B, 12TH FLOOR\nÂ \nÂ \nÂ \nA. AHU-8, PENTHOUSE\nB: AHU-1, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 7, PENTHOUSE\nD. EXHAUST 5, PENTHOUSE\nÂ \nÂ \nE: RETURN FAN 4, IN AHU-8\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n20) EMERGENCY ROOM 1ST FLOOR\nÂ \nÂ \nÂ \nA. AHU11-A, C-LEVEL\nB. TBEF-1 EXHAUST, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 5, PENTHOUSE\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n21) RADIATION THERAPY, A-LEVEL, WING D\nÂ \nÂ \nÂ \nA. AHU-1D, A-LEVEL ROOF\nB. RETURN FAN 1D, A-LEVEL ROOF\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n22) AAALAC SURVEY IN BLDG. 7 VIVARIUM\nÂ \nÂ \nÂ \n1) AREA B\nÂ \nÂ \nÂ \nA.  AHU-B LOWER ROOF TOP\nB. EF-7-2 ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n2) AREA C\nÂ \nÂ \nÂ \nA. AHU-C AHU-B LOWER ROOF TOP\nB. EF-7-3 ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n3) AREA D\nÂ \nÂ \nÂ \nA. AHU-D AHU-B LOWER ROOF TOP\nB. EF-D ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n4) AREA E\nÂ \nÂ \nÂ \nA. AHU-E BASEMENT\nB. EF-E ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n5) AREA X\nÂ \nÂ \nÂ \nA. AHU-X UPPER ROOF TOP\nB. EF-X ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nTRAVERSE'S TO BE DONE ANNUALLY IN THE 2ND QUARTER\nÂ \nÂ \nÂ \n23) AHU-1 PENTHOUSE ROOF\n24) AHU-2 PENTHOUSE\n25) AHU-3 PENTHOUSE\nÂ \n26) AHU-4 PENTHOUSE\n27) AHU-5 PENTHOUSE\n28) AHU-6 PENTHOUSE\n29) AHU-7 PENTHOUSE\n30) AHU-8 PENTHOUSE\n31) AHU-9 B-LEVEL ROOF\n32) AHU-10 3-171A\n33) AHU-11 C-132\n34) AHU-11A C-132\n35) AHU-12 C-132\n36) AHU-13 C-132\n37) AHU-17 B-LEVEL ROOF\n38) A-LEVEL LAB AHU A-146\n39) 5-C AHU 6TH FLOOR C-WING ROOF\n40) AUDIOLOGY AHU 4-246\n41) ECHO LAB AHU 6TH FLOOR D-WING ROOF\n42) AHU-1D A-LEVEL ROOF\n43) 2D AHU ON ROOF OUTSIDE OF ROOM 2-437\n44) CATH LAB UNIT 9-163\n45) FILE ROOM AHU A-128D\nÂ \nÂ \n\n\n\nÂ \nLYONS CAMPUS EQUIPMENT:\nÂ \nÂ \nÂ \nALL WORK TO BE DONE SEMI-ANNUALLY IN THE 1ST QUARTER AND 3RD QUARTER\nÂ \n1) SPD- BUILDING #1\nÂ \nÂ \nÂ \nA. CLEAN STORAGE AREA\nB. DECONTAMINATION AREA\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n 2) BUILDING # 3   NEGATIVE PRESSURE ROOMS\nÂ \nÂ \nÂ \nA. D114\nB. E116\nC. F114\nD. H114\nE. G113\nF.  H112\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n3) BUILDING #4   NEGATIVE PRESSURE ROOM\nÂ \nÂ \nÂ \nA.  56\nÂ \nÂ \nÂ \nBUILDIING # 3\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nB.  PHARMACY\nÂ \nÂ \nÂ \nBUILDING # 135 CLC\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nC. PHARMACY\nÂ \nÂ \nÂ \n BUILDING # 53\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nD.   PHARMACY\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n\n\n\n8. WORKING HOURS: \nAll work shall be performed at East Orange for the following areas evenings After 5:00pm or weekends. \nO.R. s, SPS, Endoscopy, Dental, Pharmacy, Histology, Cath Lab, the Morgue, Gamma Camera, Radiation Therapy and Radiology.\n\nLyons and all other areas at East Orange can be done between the hours of 8:00 AM to 4:30 PM, Monday to Friday excluding Federal Holidays. Contractor shall not perform work outside of these hours without prior approval fromÂ COR/Facility Manager.Â Â \n\n9. FEDERAL HOLIDAYS:  \nFederal Holidays which are observed by the federal government are annotated below. \nNew Year s Day\nMartin Luther King s Birthday\nPresident s Day\nMemorial Day\nIndependence Day         -\nLabor Day\nColumbus Day\nVeterans Day\nThanksgiving Day\nChristmas Day\n\n10. PERIOD OF PERFORMANCE:Â \nThe period of performance for these services will be one year from date of award of contract with the provision of four (4) option years.","text":"This is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law.\n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Bronx, NY for the purpose of collecting information on Air balancing, inspecting and testing services for the New Jersey Health Care System VA Medical Center, Lyons Campus at 151 Knollcroft Road, Lyons, NJ 07939 and East Orange Campus at 385 Tremont Avenue, East Orange, NJ 07018. The VA is seeking to provide for this requirement as of 06/01/2025 to establish a new service. The NAICS code identified for this requirement is 238220 Plumbing, Heating and Air-Conditioning Contractors. The requirement is detailed in the Statement of Work section of this document.\n\n(e) Cursory market research has identified several small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment are encouraged to email a capability statement and full information to Natalie Acevedo at Natalie.Acevedo@va.gov Monday, April 7, 2025 at 10:00 AM EST.\n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category. Contractors shall identify the NAICS code for the services being offered as well as their size status under said NAICS. If contractor is a Service-Disabled Veteran Owned Small Business (SDVOSB), a Veteran Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the package, this may result in the contractor not being considered in the Government s Procurement Strategy.\n\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired services.\n- Contractors shall identify pertinent point of contact for company, contractor EIN number for size standard and socioeconomic verification in SAM and SBA VetCert, as well as for any intended subcontractors.\n- Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs.\n- Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded.\n- Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable.\n\n- Contractors shall include any relevant comments about the Attachment(s) if applicable.\n\nSTATEMENT OF WORK\n\nAIR BALANCING SERVICES\n\n1. BACKGROUND:\nThe Department of Veterans Affairs New Jersey Health Care System is currently seeking for air balancing, adjusting and testing services for Lyons Campus and East Orange Campus. Lyons Campus which was built in the early 1920 s with over 30 major buildings and a few smaller outbuildings sits on 306 acres. East Orange Campus is located on 3 acres with one (1) high-rise building of 13 floors and 12 outbuildings. Contractor shall provide air balancing services for the above two campus at specified months, and quarters as stated in this document and under Equipment List.\n\n2. SCOPE OF WORK:\nContractor shall provide all supervision, labor, materials and equipment necessary to perform air balancing, traverses of air handlers and exhaust systems and provide all related documentation for both campuses.\n\n3. SPECIFICATIONS:\nContractor shall take CFM (Cubic Feet per Minute) readings from supply and exhaust and make necessary adjustments for the designated areas to be in compliance with room-to-room pressurization design criteria.\n\nContractor will take test readings of each diffuser and grill to include the required Feet per Minute/Cubic Feet per Minute, test results of the Feet Per Minute/. Cubic Feet per Minute and provide instrument calibration reports to comply with requirements in ASHRAE 111, Section 4, Instrumentation. And to provide instrumentation calibration reports to include, instrument type and make, serial number, application, dates of use and dates of calibration.\n\n4. REPORTS:\nContractor shall provide 3 hard copy reports of all readings for both campuses in their TAB (testing, Adjusting and Balancing) report.\n\nAn electronic version of same report shall be sent to the Contracting Officer Representative. Contractor will provide reports in triplicate to include:\n\nA print of the area showing air flow directions and pressures.\nAir exchange per hour for each room or corridor to include room volume, cu , design and actual Cubic Feet per Minute for supply and exhaust air\nCertificate of recalibration for all testing equipment.\n\nService Reports must be signed by both service provider and Contracting Officer Representative at the completion of each work.\n\nÂ\n5. FREQUENCY:\nContractor shall conduct air balancing, testing and adjusting annually in the 2nd Quarter and semi-annually in the 1st and 3rd Quarters for:\n\n1) East Orange Campus\n385 Tremont Avenue\nEast Orange, NJ 07018-109\n\nContractor shall conduct air balancing, testing and adjusting quarterly in the 1st and 3rd quarters for:\n\n2) Lyons Campus\n151 Knollcroft Road\nLyons, NJ 07939\n\n6. REQUIREMENTS:Â\nContractor shall demonstrate that it is a firm regularly engaged in the field of air balancing services.\n\nContractor must be certified in Air balancing and must be licensed and insured for this type of work.\n\nContractor shall be certified by either AABC (Associated Air Balance Council) or NEBB (National Environmental Bureau) and provide personnel who are AABC or NEBB certified and qualified to do air balancing.\n\nContractor shall provide certification as required by the Joint Commission on the Accreditation of Healthcare Organizations (JCAHO) with a valid 30-hour safety card for personnel identified to work on this requirement.\n\nContractor shall follow all the Department of Veterans Affair Administrations, State, Federal and OSHA rules and safety regulations.\n\n7. EQUIPMENT LIST:\n\nEAST ORANGE EQUIPMENT LIST:\nÂ\nÂ\nÂ\nAREAS TO BE DONE SEMI-ANNUALLY IN THE 1ST AND 3RD QUARTERS\nÂ\nÂ\n1) O.R. 2ND FLOOR, C-WING\nÂ\nÂ\nÂ\nAHU 33 C LEVEL\nB. AHU-34 C LEVEL\nC. AHU-35\nC LEVEL\nD. EXHAUST #1 1ST FLR C W\nE. EXHAUST #2\nF. EXHAUST 40A\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n2) SPS 2ND. FLOOR, B-WING\nÂ\nÂ\nÂ\nA. SPS AIR HANDLER 2ND FLR\nB. EXHAUST #1\n6TH FLR ROOF\nEXHAUST #2\n6TH FLR ROOF\nD. EXHAUST 6TH FLR ROOF\nE. EXHAUST #4\nF. EXHAUST #5\nG. EXHAUST #6\nÂ\nÂ 6TH FLR ROOF\nÂ 6TH FLR ROOR\nÂ 6FLR ROOF\nÂ\n3)Â ENDOSCOPY 2ND. FLOOR, B-WING\nÂ\nÂ\nÂ\nA. ENDOSCOPY AHU 2ND FLOOR B-W\nB. EXHAUST #1\nC. EXHAUST #2\nÂ\nÂ\nÂ 6TH FLR B WING\nÂ 6TH FLR B WING\nÂ\n4) DENTAL 3RD FLOOR, B-WING - DENTAL AHU\nÂ\nÂ\nÂ\nA. EXHAUST #1\nB. EXHAUST #2\nÂ\nÂ\nÂ 6TH FLOOR ROOF B SIDE\nÂ 6TH FLOOR ROOF B SIDE\nÂ\nÂ\n5)Â Â Â PHARMACY IV ROOM 8TH FLOOR, A-WING\nÂ\nÂ\nÂ\nA. PHARMACY AHU B LEVEL ROOF\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n6)Â Â HISTOLOGY A-LEVEL, B WING\nÂ\nÂ\nÂ\nA. AHU-1, A-146\nB. HOOD EXHAUST 6TH FLOOR ROOF B-WING\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n7)Â Â Â CATH. LAB 9-166\nÂ\nÂ\nÂ\nA. AHU CATH. LAB 9-163\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n8)Â Â Â MORGUE B-LEVEL, C-WING\nÂ\nÂ\nÂ\nA. AHU 10A C LEVEL\nB. TBEF #7\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n9) GAMMA CAMERA 6-CORE\nÂ\nÂ\nÂ\nA. AHU-2 PENTHOUSE\nB. AHU-5 PENTHOUSE\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nAREAS TO BE DONE ANNUALLY IN THE 2ND QUARTER\nÂ\nÂ\n10) FIRST FLOOR LAB 1ST FLOOR B-WING\nÂ\nÂ\nÂ\nA. AHU-17 B-LEVEL ROOF\nB. EXHAUST, 6TH FLOOR ROOF, B-WING ROOF\nÂ\nÂ\nC. HOOD EXHAUST, 6TH FLOOR ROOF, B-WING ROOF\nÂ\nÂ\nÂ\n\n11) FIRST FLOOR RADIOLGY C WING\n\nAHU A LEVEL ROOF OVER A-215\n\nÂ\nÂ\nÂ\n12) NEW ED A WING\n\nAHU ROOF OF ED\n2ND FLOOR ROOF A WING\nEXHAUST AUDITORIUM ROOF\n\n13) SICU/MICU 2ND FLOOR, D-WING\nÂ\nÂ\nÂ\nA. AHU-2D, 2ND FLOOR ROOF\nB. EXHAUST 21, PENTHOUSE\nÂ\nÂ\nC. ISOLATION EXHAUST 3RD FLOOR BUMP-OUT.\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n14) WARD 5B, FLOOR 5 B-WING\nÂ\nÂ\nÂ\nA. AHU-1 PENTHOUSE\nB. AHU-4, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 4 PENTHOUSE\nD. MUSHROOM ON 6B ROOF\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n15) WARD 5-C, FLOOR 5 C-WING\nÂ\nÂ\nÂ\nA. AHU-5C, 6TH FLOOR ROOF C-WING\nB. EXHAUST 1, 6TH FLOOR ROOF C-WING\nÂ\nÂ\nC. EXHAUST 2, 6TH FLOOR ROOF C-WING\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n16) WARD 5D, FLOOR 5, D-WING\nÂ\nÂ\nÂ\nA. AHU-3, PENTHOUSE\nB. AHU-6, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 18 PENTHOUSE\nD. EXHAUST, MUSHROOM ON 6D ROOF\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n17) WARD 6B, FLOOR 6 B-WING\nÂ\nÂ\nÂ\nA. AHU-1, PENTHOUSE\nB. AHU-4, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 10, PENTHOUSE\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n18) WARD 9A, 9TH FLOOR, A-WING\nÂ\nÂ\nÂ\nA. AHU-3, PENTHOUSE\nB. AHU-6, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 23, PENTHOUSE\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n19) WARD 12B, 12TH FLOOR\nÂ\nÂ\nÂ\nA. AHU-8, PENTHOUSE\nB: AHU-1, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 7, PENTHOUSE\nD. EXHAUST 5, PENTHOUSE\nÂ\nÂ\nE: RETURN FAN 4, IN AHU-8\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n20) EMERGENCY ROOM 1ST FLOOR\nÂ\nÂ\nÂ\nA. AHU11-A, C-LEVEL\nB. TBEF-1 EXHAUST, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 5, PENTHOUSE\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n21) RADIATION THERAPY, A-LEVEL, WING D\nÂ\nÂ\nÂ\nA. AHU-1D, A-LEVEL ROOF\nB. RETURN FAN 1D, A-LEVEL ROOF\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n22) AAALAC SURVEY IN BLDG. 7 VIVARIUM\nÂ\nÂ\nÂ\n1) AREA B\nÂ\nÂ\nÂ\nA. AHU-B LOWER ROOF TOP\nB. EF-7-2 ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n2) AREA C\nÂ\nÂ\nÂ\nA. AHU-C AHU-B LOWER ROOF TOP\nB. EF-7-3 ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n3) AREA D\nÂ\nÂ\nÂ\nA. AHU-D AHU-B LOWER ROOF TOP\nB. EF-D ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n4) AREA E\nÂ\nÂ\nÂ\nA. AHU-E BASEMENT\nB. EF-E ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n5) AREA X\nÂ\nÂ\nÂ\nA. AHU-X UPPER ROOF TOP\nB. EF-X ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nTRAVERSE'S TO BE DONE ANNUALLY IN THE 2ND QUARTER\nÂ\nÂ\nÂ\n23) AHU-1 PENTHOUSE ROOF\n24) AHU-2 PENTHOUSE\n25) AHU-3 PENTHOUSE\nÂ\n26) AHU-4 PENTHOUSE\n27) AHU-5 PENTHOUSE\n28) AHU-6 PENTHOUSE\n29) AHU-7 PENTHOUSE\n30) AHU-8 PENTHOUSE\n31) AHU-9 B-LEVEL ROOF\n32) AHU-10 3-171A\n33) AHU-11 C-132\n34) AHU-11A C-132\n35) AHU-12 C-132\n36) AHU-13 C-132\n37) AHU-17 B-LEVEL ROOF\n38) A-LEVEL LAB AHU A-146\n39) 5-C AHU 6TH FLOOR C-WING ROOF\n40) AUDIOLOGY AHU 4-246\n41) ECHO LAB AHU 6TH FLOOR D-WING ROOF\n42) AHU-1D A-LEVEL ROOF\n43) 2D AHU ON ROOF OUTSIDE OF ROOM 2-437\n44) CATH LAB UNIT 9-163\n45) FILE ROOM AHU A-128D\nÂ\nÂ\n\nÂ\nLYONS CAMPUS EQUIPMENT:\nÂ\nÂ\nÂ\nALL WORK TO BE DONE SEMI-ANNUALLY IN THE 1ST QUARTER AND 3RD QUARTER\nÂ\n1) SPD- BUILDING #1\nÂ\nÂ\nÂ\nA. CLEAN STORAGE AREA\nB. DECONTAMINATION AREA\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n2) BUILDING # 3 NEGATIVE PRESSURE ROOMS\nÂ\nÂ\nÂ\nA. D114\nB. E116\nC. F114\nD. H114\nE. G113\nF. H112\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n3) BUILDING #4 NEGATIVE PRESSURE ROOM\nÂ\nÂ\nÂ\nA. 56\nÂ\nÂ\nÂ\nBUILDIING # 3\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nB. PHARMACY\nÂ\nÂ\nÂ\nBUILDING # 135 CLC\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nC. PHARMACY\nÂ\nÂ\nÂ\nBUILDING # 53\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nD. PHARMACY\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n\n8. WORKING HOURS:\nAll work shall be performed at East Orange for the following areas evenings After 5:00pm or weekends.\nO.R. s, SPS, Endoscopy, Dental, Pharmacy, Histology, Cath Lab, the Morgue, Gamma Camera, Radiation Therapy and Radiology.\n\nLyons and all other areas at East Orange can be done between the hours of 8:00 AM to 4:30 PM, Monday to Friday excluding Federal Holidays. Contractor shall not perform work outside of these hours without prior approval fromÂ COR/Facility Manager.Â Â\n\n9. FEDERAL HOLIDAYS:\nFederal Holidays which are observed by the federal government are annotated below.\nNew Year s Day\nMartin Luther King s Birthday\nPresident s Day\nMemorial Day\nIndependence Day -\nLabor Day\nColumbus Day\nVeterans Day\nThanksgiving Day\nChristmas Day\n\n10. PERIOD OF PERFORMANCE:Â\nThe period of performance for these services will be one year from date of award of contract with the provision of four (4) option years.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24225Q0508","place_of_performance":{"street":"New Jersey VA Healthcare System East Orange Campus","street2":"Lyons Campus"},"product_service_code":"H999"}],"due_at":"2025-04-07T14:00:00Z","due_date":"2025-04-07","closes_at":"2025-04-07T14:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NJ","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"description","state_evidence":"YONS CAMPUS AT 151 KNOLLCROFT ROAD, LYONS, NJ 07939","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-19T08:56:40.189144Z","principal_notice_id":"394f83e4c9674597a084841c50c752e3","description":{"text":"This is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law.\n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Bronx, NY for the purpose of collecting information on Air balancing, inspecting and testing services for the New Jersey Health Care System VA Medical Center, Lyons Campus at 151 Knollcroft Road, Lyons, NJ 07939 and East Orange Campus at 385 Tremont Avenue, East Orange, NJ 07018. The VA is seeking to provide for this requirement as of 06/01/2025 to establish a new service. The NAICS code identified for this requirement is 238220 Plumbing, Heating and Air-Conditioning Contractors. The requirement is detailed in the Statement of Work section of this document.\n\n(e) Cursory market research has identified several small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment are encouraged to email a capability statement and full information to Natalie Acevedo at Natalie.Acevedo@va.gov Monday, April 7, 2025 at 10:00 AM EST.\n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category. Contractors shall identify the NAICS code for the services being offered as well as their size status under said NAICS. If contractor is a Service-Disabled Veteran Owned Small Business (SDVOSB), a Veteran Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the package, this may result in the contractor not being considered in the Government s Procurement Strategy.\n\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired services.\n- Contractors shall identify pertinent point of contact for company, contractor EIN number for size standard and socioeconomic verification in SAM and SBA VetCert, as well as for any intended subcontractors.\n- Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs.\n- Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded.\n- Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable.\n\n- Contractors shall include any relevant comments about the Attachment(s) if applicable.\n\nSTATEMENT OF WORK\n\nAIR BALANCING SERVICES\n\n1. BACKGROUND:\nThe Department of Veterans Affairs New Jersey Health Care System is currently seeking for air balancing, adjusting and testing services for Lyons Campus and East Orange Campus. Lyons Campus which was built in the early 1920 s with over 30 major buildings and a few smaller outbuildings sits on 306 acres. East Orange Campus is located on 3 acres with one (1) high-rise building of 13 floors and 12 outbuildings. Contractor shall provide air balancing services for the above two campus at specified months, and quarters as stated in this document and under Equipment List.\n\n2. SCOPE OF WORK:\nContractor shall provide all supervision, labor, materials and equipment necessary to perform air balancing, traverses of air handlers and exhaust systems and provide all related documentation for both campuses.\n\n3. SPECIFICATIONS:\nContractor shall take CFM (Cubic Feet per Minute) readings from supply and exhaust and make necessary adjustments for the designated areas to be in compliance with room-to-room pressurization design criteria.\n\nContractor will take test readings of each diffuser and grill to include the required Feet per Minute/Cubic Feet per Minute, test results of the Feet Per Minute/. Cubic Feet per Minute and provide instrument calibration reports to comply with requirements in ASHRAE 111, Section 4, Instrumentation. And to provide instrumentation calibration reports to include, instrument type and make, serial number, application, dates of use and dates of calibration.\n\n4. REPORTS:\nContractor shall provide 3 hard copy reports of all readings for both campuses in their TAB (testing, Adjusting and Balancing) report.\n\nAn electronic version of same report shall be sent to the Contracting Officer Representative. Contractor will provide reports in triplicate to include:\n\nA print of the area showing air flow directions and pressures.\nAir exchange per hour for each room or corridor to include room volume, cu , design and actual Cubic Feet per Minute for supply and exhaust air\nCertificate of recalibration for all testing equipment.\n\nService Reports must be signed by both service provider and Contracting Officer Representative at the completion of each work.\n\nÂ\n5. FREQUENCY:\nContractor shall conduct air balancing, testing and adjusting annually in the 2nd Quarter and semi-annually in the 1st and 3rd Quarters for:\n\n1) East Orange Campus\n385 Tremont Avenue\nEast Orange, NJ 07018-109\n\nContractor shall conduct air balancing, testing and adjusting quarterly in the 1st and 3rd quarters for:\n\n2) Lyons Campus\n151 Knollcroft Road\nLyons, NJ 07939\n\n6. REQUIREMENTS:Â\nContractor shall demonstrate that it is a firm regularly engaged in the field of air balancing services.\n\nContractor must be certified in Air balancing and must be licensed and insured for this type of work.\n\nContractor shall be certified by either AABC (Associated Air Balance Council) or NEBB (National Environmental Bureau) and provide personnel who are AABC or NEBB certified and qualified to do air balancing.\n\nContractor shall provide certification as required by the Joint Commission on the Accreditation of Healthcare Organizations (JCAHO) with a valid 30-hour safety card for personnel identified to work on this requirement.\n\nContractor shall follow all the Department of Veterans Affair Administrations, State, Federal and OSHA rules and safety regulations.\n\n7. EQUIPMENT LIST:\n\nEAST ORANGE EQUIPMENT LIST:\nÂ\nÂ\nÂ\nAREAS TO BE DONE SEMI-ANNUALLY IN THE 1ST AND 3RD QUARTERS\nÂ\nÂ\n1) O.R. 2ND FLOOR, C-WING\nÂ\nÂ\nÂ\nAHU 33 C LEVEL\nB. AHU-34 C LEVEL\nC. AHU-35\nC LEVEL\nD. EXHAUST #1 1ST FLR C W\nE. EXHAUST #2\nF. EXHAUST 40A\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n2) SPS 2ND. FLOOR, B-WING\nÂ\nÂ\nÂ\nA. SPS AIR HANDLER 2ND FLR\nB. EXHAUST #1\n6TH FLR ROOF\nEXHAUST #2\n6TH FLR ROOF\nD. EXHAUST 6TH FLR ROOF\nE. EXHAUST #4\nF. EXHAUST #5\nG. EXHAUST #6\nÂ\nÂ 6TH FLR ROOF\nÂ 6TH FLR ROOR\nÂ 6FLR ROOF\nÂ\n3)Â ENDOSCOPY 2ND. FLOOR, B-WING\nÂ\nÂ\nÂ\nA. ENDOSCOPY AHU 2ND FLOOR B-W\nB. EXHAUST #1\nC. EXHAUST #2\nÂ\nÂ\nÂ 6TH FLR B WING\nÂ 6TH FLR B WING\nÂ\n4) DENTAL 3RD FLOOR, B-WING - DENTAL AHU\nÂ\nÂ\nÂ\nA. EXHAUST #1\nB. EXHAUST #2\nÂ\nÂ\nÂ 6TH FLOOR ROOF B SIDE\nÂ 6TH FLOOR ROOF B SIDE\nÂ\nÂ\n5)Â Â Â PHARMACY IV ROOM 8TH FLOOR, A-WING\nÂ\nÂ\nÂ\nA. PHARMACY AHU B LEVEL ROOF\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n6)Â Â HISTOLOGY A-LEVEL, B WING\nÂ\nÂ\nÂ\nA. AHU-1, A-146\nB. HOOD EXHAUST 6TH FLOOR ROOF B-WING\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n7)Â Â Â CATH. LAB 9-166\nÂ\nÂ\nÂ\nA. AHU CATH. LAB 9-163\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n8)Â Â Â MORGUE B-LEVEL, C-WING\nÂ\nÂ\nÂ\nA. AHU 10A C LEVEL\nB. TBEF #7\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n9) GAMMA CAMERA 6-CORE\nÂ\nÂ\nÂ\nA. AHU-2 PENTHOUSE\nB. AHU-5 PENTHOUSE\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nAREAS TO BE DONE ANNUALLY IN THE 2ND QUARTER\nÂ\nÂ\n10) FIRST FLOOR LAB 1ST FLOOR B-WING\nÂ\nÂ\nÂ\nA. AHU-17 B-LEVEL ROOF\nB. EXHAUST, 6TH FLOOR ROOF, B-WING ROOF\nÂ\nÂ\nC. HOOD EXHAUST, 6TH FLOOR ROOF, B-WING ROOF\nÂ\nÂ\nÂ\n\n11) FIRST FLOOR RADIOLGY C WING\n\nAHU A LEVEL ROOF OVER A-215\n\nÂ\nÂ\nÂ\n12) NEW ED A WING\n\nAHU ROOF OF ED\n2ND FLOOR ROOF A WING\nEXHAUST AUDITORIUM ROOF\n\n13) SICU/MICU 2ND FLOOR, D-WING\nÂ\nÂ\nÂ\nA. AHU-2D, 2ND FLOOR ROOF\nB. EXHAUST 21, PENTHOUSE\nÂ\nÂ\nC. ISOLATION EXHAUST 3RD FLOOR BUMP-OUT.\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n14) WARD 5B, FLOOR 5 B-WING\nÂ\nÂ\nÂ\nA. AHU-1 PENTHOUSE\nB. AHU-4, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 4 PENTHOUSE\nD. MUSHROOM ON 6B ROOF\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n15) WARD 5-C, FLOOR 5 C-WING\nÂ\nÂ\nÂ\nA. AHU-5C, 6TH FLOOR ROOF C-WING\nB. EXHAUST 1, 6TH FLOOR ROOF C-WING\nÂ\nÂ\nC. EXHAUST 2, 6TH FLOOR ROOF C-WING\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n16) WARD 5D, FLOOR 5, D-WING\nÂ\nÂ\nÂ\nA. AHU-3, PENTHOUSE\nB. AHU-6, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 18 PENTHOUSE\nD. EXHAUST, MUSHROOM ON 6D ROOF\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n17) WARD 6B, FLOOR 6 B-WING\nÂ\nÂ\nÂ\nA. AHU-1, PENTHOUSE\nB. AHU-4, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 10, PENTHOUSE\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n18) WARD 9A, 9TH FLOOR, A-WING\nÂ\nÂ\nÂ\nA. AHU-3, PENTHOUSE\nB. AHU-6, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 23, PENTHOUSE\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n19) WARD 12B, 12TH FLOOR\nÂ\nÂ\nÂ\nA. AHU-8, PENTHOUSE\nB: AHU-1, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 7, PENTHOUSE\nD. EXHAUST 5, PENTHOUSE\nÂ\nÂ\nE: RETURN FAN 4, IN AHU-8\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n20) EMERGENCY ROOM 1ST FLOOR\nÂ\nÂ\nÂ\nA. AHU11-A, C-LEVEL\nB. TBEF-1 EXHAUST, PENTHOUSE\nÂ\nÂ\nC. EXHAUST 5, PENTHOUSE\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n21) RADIATION THERAPY, A-LEVEL, WING D\nÂ\nÂ\nÂ\nA. AHU-1D, A-LEVEL ROOF\nB. RETURN FAN 1D, A-LEVEL ROOF\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n22) AAALAC SURVEY IN BLDG. 7 VIVARIUM\nÂ\nÂ\nÂ\n1) AREA B\nÂ\nÂ\nÂ\nA. AHU-B LOWER ROOF TOP\nB. EF-7-2 ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n2) AREA C\nÂ\nÂ\nÂ\nA. AHU-C AHU-B LOWER ROOF TOP\nB. EF-7-3 ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n3) AREA D\nÂ\nÂ\nÂ\nA. AHU-D AHU-B LOWER ROOF TOP\nB. EF-D ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n4) AREA E\nÂ\nÂ\nÂ\nA. AHU-E BASEMENT\nB. EF-E ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n5) AREA X\nÂ\nÂ\nÂ\nA. AHU-X UPPER ROOF TOP\nB. EF-X ROOF TOP\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nTRAVERSE'S TO BE DONE ANNUALLY IN THE 2ND QUARTER\nÂ\nÂ\nÂ\n23) AHU-1 PENTHOUSE ROOF\n24) AHU-2 PENTHOUSE\n25) AHU-3 PENTHOUSE\nÂ\n26) AHU-4 PENTHOUSE\n27) AHU-5 PENTHOUSE\n28) AHU-6 PENTHOUSE\n29) AHU-7 PENTHOUSE\n30) AHU-8 PENTHOUSE\n31) AHU-9 B-LEVEL ROOF\n32) AHU-10 3-171A\n33) AHU-11 C-132\n34) AHU-11A C-132\n35) AHU-12 C-132\n36) AHU-13 C-132\n37) AHU-17 B-LEVEL ROOF\n38) A-LEVEL LAB AHU A-146\n39) 5-C AHU 6TH FLOOR C-WING ROOF\n40) AUDIOLOGY AHU 4-246\n41) ECHO LAB AHU 6TH FLOOR D-WING ROOF\n42) AHU-1D A-LEVEL ROOF\n43) 2D AHU ON ROOF OUTSIDE OF ROOM 2-437\n44) CATH LAB UNIT 9-163\n45) FILE ROOM AHU A-128D\nÂ\nÂ\n\nÂ\nLYONS CAMPUS EQUIPMENT:\nÂ\nÂ\nÂ\nALL WORK TO BE DONE SEMI-ANNUALLY IN THE 1ST QUARTER AND 3RD QUARTER\nÂ\n1) SPD- BUILDING #1\nÂ\nÂ\nÂ\nA. CLEAN STORAGE AREA\nB. DECONTAMINATION AREA\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n2) BUILDING # 3 NEGATIVE PRESSURE ROOMS\nÂ\nÂ\nÂ\nA. D114\nB. E116\nC. F114\nD. H114\nE. G113\nF. H112\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n3) BUILDING #4 NEGATIVE PRESSURE ROOM\nÂ\nÂ\nÂ\nA. 56\nÂ\nÂ\nÂ\nBUILDIING # 3\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nB. PHARMACY\nÂ\nÂ\nÂ\nBUILDING # 135 CLC\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nC. PHARMACY\nÂ\nÂ\nÂ\nBUILDING # 53\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nD. PHARMACY\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\nÂ\n\n8. WORKING HOURS:\nAll work shall be performed at East Orange for the following areas evenings After 5:00pm or weekends.\nO.R. s, SPS, Endoscopy, Dental, Pharmacy, Histology, Cath Lab, the Morgue, Gamma Camera, Radiation Therapy and Radiology.\n\nLyons and all other areas at East Orange can be done between the hours of 8:00 AM to 4:30 PM, Monday to Friday excluding Federal Holidays. Contractor shall not perform work outside of these hours without prior approval fromÂ COR/Facility Manager.Â Â\n\n9. FEDERAL HOLIDAYS:\nFederal Holidays which are observed by the federal government are annotated below.\nNew Year s Day\nMartin Luther King s Birthday\nPresident s Day\nMemorial Day\nIndependence Day -\nLabor Day\nColumbus Day\nVeterans Day\nThanksgiving Day\nChristmas Day\n\n10. PERIOD OF PERFORMANCE:Â\nThe period of performance for these services will be one year from date of award of contract with the provision of four (4) option years.","html":"This is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law. \n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Bronx, NY for the purpose of collecting information on Air balancing, inspecting and testing services for the New Jersey Health Care System VA Medical Center, Lyons Campus at 151 Knollcroft Road, Lyons, NJ 07939 and East Orange Campus at 385 Tremont Avenue, East Orange, NJ 07018. The VA is seeking to provide for this requirement as of 06/01/2025 to establish a new service. The NAICS code identified for this requirement is 238220 Plumbing, Heating and Air-Conditioning Contractors. The requirement is detailed in the Statement of Work section of this document. \n\n(e) Cursory market research has identified several small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment are encouraged to email a capability statement and full information to Natalie Acevedo at Natalie.Acevedo@va.gov Monday, April 7, 2025 at 10:00 AM EST. \n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category. Contractors shall identify the NAICS code for the services being offered as well as their size status under said NAICS. If contractor is a Service-Disabled Veteran Owned Small Business (SDVOSB), a Veteran Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the package, this may result in the contractor not being considered in the Government s Procurement Strategy. \n\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired services. \n- Contractors shall identify pertinent point of contact for company, contractor EIN number for size standard and socioeconomic verification in SAM and  SBA VetCert, as well as for any intended subcontractors. \n - Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include subcontractors for those jobs. \n - Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. \n- Contractor shall supply proof of any applicable certification or training required to meet the regulatory requirements, if applicable. \n\n- Contractors shall include any relevant comments about the Attachment(s) if applicable. \n\nSTATEMENT OF WORK\n\nAIR BALANCING SERVICES\n\n1. BACKGROUND: \nThe Department of Veterans Affairs New Jersey Health Care System is currently seeking for air balancing, adjusting and testing services for Lyons Campus and East Orange Campus. Lyons Campus which was built in the early 1920 s with over 30 major buildings and a few smaller outbuildings sits on 306 acres. East Orange Campus is located on 3 acres with one (1) high-rise building of 13 floors and 12 outbuildings. Contractor shall provide air balancing services for the above two campus at specified months, and quarters as stated in this document and under Equipment List.\n\n2. SCOPE OF WORK: \nContractor shall provide all supervision, labor, materials and equipment necessary to perform air balancing, traverses of air handlers and exhaust systems and provide all related documentation for both campuses.  \n\n3. SPECIFICATIONS:\nContractor shall take CFM (Cubic Feet per Minute) readings from supply and exhaust and make necessary adjustments for the designated areas to be in compliance with room-to-room pressurization design criteria.\n\nContractor will take test readings of each diffuser and grill to include the required Feet per Minute/Cubic Feet per Minute, test results of the Feet Per Minute/. Cubic Feet per Minute and provide instrument calibration reports to comply with requirements in ASHRAE 111, Section 4, Instrumentation. And to provide instrumentation calibration reports to include, instrument type and make, serial number, application, dates of use and dates of calibration.\n\n4. REPORTS: \nContractor shall provide 3 hard copy reports of all readings for both campuses in their TAB (testing, Adjusting and Balancing) report. \n\nAn electronic version of same report shall be sent to the Contracting Officer Representative. Contractor will provide reports in triplicate to include:\n\nA print of the area showing air flow directions and pressures.\nAir exchange per hour for each room or corridor to include room volume, cu , design and actual Cubic Feet per Minute for supply and exhaust air\nCertificate of recalibration for all testing equipment.       \n\nService Reports must be signed by both service provider and Contracting Officer Representative at the completion of each work.\n\nÂ \n5. FREQUENCY: \nContractor shall conduct air balancing, testing and adjusting annually in the 2nd Quarter and semi-annually in the 1st and 3rd Quarters for:\n\n\n1)  East Orange Campus\n 385 Tremont Avenue             \nEast Orange, NJ 07018-109\n\nContractor shall conduct air balancing, testing and adjusting quarterly in the 1st and 3rd quarters for:\n\n2)  Lyons Campus\n 151 Knollcroft Road\n Lyons, NJ 07939\n\n6. REQUIREMENTS:Â  \nContractor shall demonstrate that it is a firm regularly engaged in the field of air balancing services.  \n\nContractor must be certified in Air balancing and must be licensed and insured for this type of work. \n\nContractor shall be certified by either AABC (Associated Air Balance Council) or NEBB (National Environmental Bureau) and provide personnel who are AABC or NEBB certified and qualified to do air balancing.\n\nContractor shall provide certification as required by the Joint Commission on the Accreditation of Healthcare Organizations (JCAHO) with a valid 30-hour safety card for personnel identified to work on this requirement. \n\nContractor shall follow all the Department of Veterans Affair Administrations, State, Federal and OSHA rules and safety regulations.\n\n7. EQUIPMENT LIST:\n\nEAST ORANGE EQUIPMENT LIST: \nÂ \nÂ \nÂ \nAREAS TO BE DONE SEMI-ANNUALLY IN THE 1ST AND 3RD QUARTERS\nÂ \nÂ \n1)  O.R. 2ND FLOOR, C-WING\nÂ \nÂ \nÂ \nAHU 33 C LEVEL\nB. AHU-34 C LEVEL\nC. AHU-35 \nC  LEVEL\nD. EXHAUST #1 1ST FLR C W\nE. EXHAUST #2\nF. EXHAUST 40A\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n2)   SPS 2ND. FLOOR, B-WING\nÂ \nÂ \nÂ \nA. SPS AIR HANDLER 2ND FLR\nB. EXHAUST #1\n6TH FLR ROOF\nEXHAUST #2\n6TH FLR ROOF\nD. EXHAUST 6TH FLR ROOF\nE. EXHAUST #4\nF. EXHAUST #5\nG. EXHAUST #6\nÂ \nÂ 6TH FLR ROOF\nÂ 6TH FLR ROOR\nÂ 6FLR ROOF\nÂ \n3)Â  ENDOSCOPY 2ND. FLOOR, B-WING\nÂ \nÂ \nÂ \nA. ENDOSCOPY AHU 2ND FLOOR B-W\nB. EXHAUST #1\nC. EXHAUST #2\nÂ \nÂ \nÂ 6TH FLR B WING\nÂ 6TH FLR B WING\nÂ \n4)  DENTAL 3RD FLOOR, B-WING - DENTAL AHU\nÂ \nÂ \nÂ \nA. EXHAUST #1\nB.  EXHAUST #2\nÂ \nÂ \nÂ 6TH FLOOR ROOF B SIDE\nÂ 6TH FLOOR ROOF B SIDE\nÂ \nÂ \n5)Â Â Â PHARMACY IV ROOM 8TH FLOOR, A-WING\nÂ \nÂ \nÂ \nA. PHARMACY AHU B LEVEL ROOF\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n6)Â Â HISTOLOGY A-LEVEL, B WING\nÂ \nÂ \nÂ \n A.  AHU-1, A-146\nB.  HOOD EXHAUST 6TH FLOOR ROOF B-WING\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n7)Â Â Â CATH. LAB 9-166\nÂ \nÂ \nÂ \nA. AHU CATH. LAB 9-163\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n8)Â Â Â MORGUE B-LEVEL, C-WING\nÂ \nÂ \nÂ \nA. AHU 10A C LEVEL\nB. TBEF #7\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n9) GAMMA CAMERA 6-CORE\nÂ \nÂ \nÂ \n A. AHU-2 PENTHOUSE\nB. AHU-5 PENTHOUSE\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nAREAS TO BE DONE ANNUALLY IN THE 2ND QUARTER\nÂ \nÂ \n10) FIRST FLOOR LAB 1ST FLOOR B-WING\nÂ \nÂ \nÂ \nA. AHU-17 B-LEVEL ROOF\nB. EXHAUST, 6TH FLOOR ROOF, B-WING ROOF\nÂ \nÂ \nC. HOOD EXHAUST, 6TH FLOOR ROOF, B-WING ROOF\nÂ \nÂ \nÂ \n\n\n\n\n11) FIRST FLOOR RADIOLGY C WING\n\n\n\nAHU A LEVEL ROOF OVER A-215\n\n\n\n\nÂ \nÂ \nÂ \n12) NEW ED A WING\n\n\n\nAHU ROOF OF ED\n2ND FLOOR ROOF A WING\nEXHAUST AUDITORIUM ROOF\n\n\n\n\n\n\n13) SICU/MICU 2ND FLOOR, D-WING\nÂ \nÂ \nÂ \nA. AHU-2D, 2ND FLOOR ROOF\nB. EXHAUST 21, PENTHOUSE\nÂ \nÂ \nC. ISOLATION EXHAUST 3RD FLOOR BUMP-OUT.\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n14) WARD 5B, FLOOR 5 B-WING\nÂ \nÂ \nÂ \nA. AHU-1 PENTHOUSE\nB. AHU-4, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 4 PENTHOUSE\nD. MUSHROOM ON 6B ROOF\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n15) WARD 5-C, FLOOR 5 C-WING\nÂ \nÂ \nÂ \nA. AHU-5C, 6TH FLOOR ROOF C-WING\nB. EXHAUST 1, 6TH FLOOR ROOF C-WING\nÂ \nÂ \nC. EXHAUST 2, 6TH FLOOR ROOF C-WING\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n16) WARD 5D, FLOOR 5, D-WING\nÂ \nÂ \nÂ \nA. AHU-3, PENTHOUSE\nB. AHU-6, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 18 PENTHOUSE\nD. EXHAUST, MUSHROOM ON 6D ROOF\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n17) WARD 6B, FLOOR 6 B-WING\nÂ \nÂ \nÂ \nA. AHU-1, PENTHOUSE\nB. AHU-4, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 10, PENTHOUSE\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n18) WARD 9A, 9TH FLOOR, A-WING\nÂ \nÂ \nÂ \nA. AHU-3, PENTHOUSE\nB. AHU-6, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 23, PENTHOUSE\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n19) WARD 12B, 12TH FLOOR\nÂ \nÂ \nÂ \nA. AHU-8, PENTHOUSE\nB: AHU-1, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 7, PENTHOUSE\nD. EXHAUST 5, PENTHOUSE\nÂ \nÂ \nE: RETURN FAN 4, IN AHU-8\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n20) EMERGENCY ROOM 1ST FLOOR\nÂ \nÂ \nÂ \nA. AHU11-A, C-LEVEL\nB. TBEF-1 EXHAUST, PENTHOUSE\nÂ \nÂ \nC. EXHAUST 5, PENTHOUSE\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n21) RADIATION THERAPY, A-LEVEL, WING D\nÂ \nÂ \nÂ \nA. AHU-1D, A-LEVEL ROOF\nB. RETURN FAN 1D, A-LEVEL ROOF\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n22) AAALAC SURVEY IN BLDG. 7 VIVARIUM\nÂ \nÂ \nÂ \n1) AREA B\nÂ \nÂ \nÂ \nA.  AHU-B LOWER ROOF TOP\nB. EF-7-2 ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n2) AREA C\nÂ \nÂ \nÂ \nA. AHU-C AHU-B LOWER ROOF TOP\nB. EF-7-3 ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n3) AREA D\nÂ \nÂ \nÂ \nA. AHU-D AHU-B LOWER ROOF TOP\nB. EF-D ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n4) AREA E\nÂ \nÂ \nÂ \nA. AHU-E BASEMENT\nB. EF-E ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n5) AREA X\nÂ \nÂ \nÂ \nA. AHU-X UPPER ROOF TOP\nB. EF-X ROOF TOP\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nTRAVERSE'S TO BE DONE ANNUALLY IN THE 2ND QUARTER\nÂ \nÂ \nÂ \n23) AHU-1 PENTHOUSE ROOF\n24) AHU-2 PENTHOUSE\n25) AHU-3 PENTHOUSE\nÂ \n26) AHU-4 PENTHOUSE\n27) AHU-5 PENTHOUSE\n28) AHU-6 PENTHOUSE\n29) AHU-7 PENTHOUSE\n30) AHU-8 PENTHOUSE\n31) AHU-9 B-LEVEL ROOF\n32) AHU-10 3-171A\n33) AHU-11 C-132\n34) AHU-11A C-132\n35) AHU-12 C-132\n36) AHU-13 C-132\n37) AHU-17 B-LEVEL ROOF\n38) A-LEVEL LAB AHU A-146\n39) 5-C AHU 6TH FLOOR C-WING ROOF\n40) AUDIOLOGY AHU 4-246\n41) ECHO LAB AHU 6TH FLOOR D-WING ROOF\n42) AHU-1D A-LEVEL ROOF\n43) 2D AHU ON ROOF OUTSIDE OF ROOM 2-437\n44) CATH LAB UNIT 9-163\n45) FILE ROOM AHU A-128D\nÂ \nÂ \n\n\n\nÂ \nLYONS CAMPUS EQUIPMENT:\nÂ \nÂ \nÂ \nALL WORK TO BE DONE SEMI-ANNUALLY IN THE 1ST QUARTER AND 3RD QUARTER\nÂ \n1) SPD- BUILDING #1\nÂ \nÂ \nÂ \nA. CLEAN STORAGE AREA\nB. DECONTAMINATION AREA\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n 2) BUILDING # 3   NEGATIVE PRESSURE ROOMS\nÂ \nÂ \nÂ \nA. D114\nB. E116\nC. F114\nD. H114\nE. G113\nF.  H112\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n3) BUILDING #4   NEGATIVE PRESSURE ROOM\nÂ \nÂ \nÂ \nA.  56\nÂ \nÂ \nÂ \nBUILDIING # 3\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nB.  PHARMACY\nÂ \nÂ \nÂ \nBUILDING # 135 CLC\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nC. PHARMACY\nÂ \nÂ \nÂ \n BUILDING # 53\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nD.   PHARMACY\nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \nÂ \n\n\n\n8. WORKING HOURS: \nAll work shall be performed at East Orange for the following areas evenings After 5:00pm or weekends. \nO.R. s, SPS, Endoscopy, Dental, Pharmacy, Histology, Cath Lab, the Morgue, Gamma Camera, Radiation Therapy and Radiology.\n\nLyons and all other areas at East Orange can be done between the hours of 8:00 AM to 4:30 PM, Monday to Friday excluding Federal Holidays. Contractor shall not perform work outside of these hours without prior approval fromÂ COR/Facility Manager.Â Â \n\n9. FEDERAL HOLIDAYS:  \nFederal Holidays which are observed by the federal government are annotated below. \nNew Year s Day\nMartin Luther King s Birthday\nPresident s Day\nMemorial Day\nIndependence Day         -\nLabor Day\nColumbus Day\nVeterans Day\nThanksgiving Day\nChristmas Day\n\n10. PERIOD OF PERFORMANCE:Â \nThe period of performance for these services will be one year from date of award of contract with the provision of four (4) option years.","origin":"detail"},"contacts":[{"name":"Natalie Acevedo","role":"primary","email":"natalie.acevedo@va.gov","phone":"718 584 9000 x4356","title":"Contracting Officer"}],"place_of_performance":{"street":"New Jersey VA Healthcare System East Orange Campus","street2":"Lyons Campus"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["238220"],"award":{"awardee":{}},"attachments":[{"resource_id":"4907fa7ca9c14ff98a4a1ff884484bea","name":"36C24225Q0508.docx","kind":"file","mime_type":".docx","size_bytes":29001,"posted_at":"2025-04-01T18:47:49.749Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/4907fa7ca9c14ff98a4a1ff884484bea/download","mirrored":false}],"awards":[],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"36C24226R0127","latest_notice_id":"2af01fdbb5af425da3127ce79f3a1d61","title":"Y1DA--561-24-600 Upgrade Mechanical Systems-C Level","solicitation_number":"36C24226R0127","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2027-01-04T15:00:00Z","due_date":"2027-01-04","closes_at":"2027-01-04T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"W911PT27QA020","latest_notice_id":"084d5efc5ec44a9885a37b90e6705ffa","title":"REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS","solicitation_number":"W911PT27QA020","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"238220","psc":"Z2NB","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"IGH VELOCITY AIR HANDLING UNITSPROJECT LOCATION: WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"2031ZA27B00001","latest_notice_id":"622efd27a6cf48589063c08d3700b96b","title":"Modernize Regenerative Thermal Oxidizer (RTO)","solicitation_number":"2031ZA27B00001","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-020","dept_name":"TREASURY, DEPARTMENT OF THE","sub_key":"s-2041","sub_name":"BUREAU OF ENGRAVING AND PRINTING","office_key":"o-2031ZA","office_name":"OFFICE OF THE CHIEF PROCUREMENT OFFICER","naics":"238220","psc":"Z2AZ","set_aside":null,"state":"TX","county":"48439","county_name":"Tarrant County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open_total":59,"indexable":false}