{"canonical":"https://sealedbidder.com/opportunities/36c24225q0492","key":"36C24225Q0492","url":"https://sealedbidder.com/opportunities/36c24225q0492","title":"J046--Monochloramine Preventative Maintenance","solicitation_number":"36C24225Q0492","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-05-19T14:00:00Z","first_posted":"2025-05-15","last_posted":"2025-05-15","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"325998","psc":"J046","set_aside":null,"place_state":"NJ","place_scope":"site","site":null,"place_state_source":"description","place_evidence":"BUTION SYSTEMS, THE VANJHCS LYONS & EAST ORANGE, NJ","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"a81d98a20d394f15a01d74d9538da17f","title":"J046--Monochloramine Preventative Maintenance","solicitation_number":"36C24225Q0492","notice_type":"s","base_type":"s","posted":"2025-05-15","posted_at":"2025-05-15T15:03:00.528Z","due_at":"2025-05-19T14:00:00Z","due_date":"2025-05-19","cancelled":false,"archived":true,"archive_date":"2025-07-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a81d98a20d394f15a01d74d9538da17f/view","enriched":true,"history":[{"index":3,"title":"J046--Monochloramine Preventative Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-15T15:03:00.528Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"a81d98a20d394f15a01d74d9538da17f","solicitation_number":"36C24225Q0492"}]}],"latest_notice_id":"a81d98a20d394f15a01d74d9538da17f","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-05-15","posted_at":"2025-05-15T15:03:00.528Z","created_at":"2025-05-15T15:02:58.253Z","modified_at":"2025-07-19T04:04:38.590Z","response_deadline":{"raw":"2025-05-19T10:00:00-04:00","utc":"2025-05-19T14:00:00Z","date":"2025-05-19","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a81d98a20d394f15a01d74d9538da17f/view"},"naics":{"codes":["325998"],"primary":"325998"},"title":"J046--Monochloramine Preventative Maintenance","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-07-18","archive_type":"auto_custom"},"history":[{"index":3,"title":"J046--Monochloramine Preventative Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-15T15:03:00.528Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"a81d98a20d394f15a01d74d9538da17f","solicitation_number":"36C24225Q0492"}],"contacts":[{"name":"Natalie Acevedo","role":"primary","email":"natalie.acevedo@va.gov","phone":"718 584 9000 x4356","title":"Contracting Officer"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"a81d98a20d394f15a01d74d9538da17f","lineage_id":"a81d98a20d394f15a01d74d9538da17f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-15T02:43:14.738494659Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"27503c040b8e669bf66d9ac696b22d42e5e29c2a8cb934af8e2fe03a1b5b341f","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-15T02:43:14.738494659Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"J046   Maintenance Repair, and Rebuilding of Equipment   Water Purification and Sewage Treatment Equipment\nSOL:Â  36C24225Q0492\nDUE:  May 20, 2025, at 10:00 AM EST.Â Â Â Â Â Â Â Â  \nSET ASIDE: N/AÂ Â Â Â Â Â Â Â Â Â Â Â Â  \nNAICS: 325998   All Other Miscellaneous Chemical Product and Preparation Manufacturing. \nPOP:  12-month Base Year with 4 option years. \nAGENCY:Â  New Jersey VA Healthcare System\nPOC:Â Natalie Acevedo, email Natalie.Acevedo@va.gov Â Â  Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â  \nDESCRIPTION: NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT TO Klenzoid, Inc.Â  \nMarket research was conducted and determined that Klenzoid, Inc.is the only vendor capable of meeting the requirement at New Jersey VAHCS. \nThis Notice of Intent is not a request for Proposals or Quotations.Â  No solicitation document exists, and no telephone or email inquiries will be accepted.Â  Â Â Â Â Â Â Â  \nNo contract award will be made based on proposals, or quotations received in response to this notice.Â  Â Â Â Â Â Â Â  \nThe government MAY consider all Expressions of Interest (EOI) received prior to May 20,2025. Â  \nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government.Â  \nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement.Â  Â  \nResponses to this notice must be emailed to Natalie.Acevedo@va.gov and received by 10:00 AM EST on May 20, 2025.Â Â  Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â  \nSubmitters are responsible for ensuring their EOI reaches the designated contracting officer on-time.Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â  \nSee attached Statement of Work below for additional details.Â Â Â Â Â  \nIf you have any questions or concerns, please contact me.\n\n\n\n\n\n\nSTATEMENT OF WORK\n\n\nA. GENERAL INFORMATION\n\nTitle of Project: Supplemental Disinfection and Continuous Water Quality Monitoring\nBackground: Per VA Directive 1061- Prevention of Healthcare Associated Legionnaires Disease and Scald Injury from Potable Water Distribution Systems, the VANJHCS Lyons & East Orange, NJ campus VA Medical Centers requires Supplemental Disinfection and Continuous Water Quality Monitoring. VANJHCS wishes to continue to lease Monochloramine Supplemental Disinfection systems and provide for the continued operation, maintenance and remote monitoring of both the Monochloramine systems and the Continuous Water Quality Monitoring and Monochloramine Stabilizer Systems. The combined requirement in accordance with the statement of work (SOW) is to provide for the continued operation and upgrading of the existing Monochloramine Generators for supplemental disinfection including the supply and maintenance of the equipment, supply and delivery of National Sanitation FoundationÂ® certified chemical reagents, parts, and labor necessary for upgrading and the continued operation and maintenance, probe calibration and replacement (as required) of the Continuous Water Quality Monitoring(CWQM) panels in the domestic cold and hot water System in compliance with the current VA 1061 Directive . \nScope of Work: The contractor shall provide all Labor and Material necessary to provide and install the specified equipment and accomplish the continued maintenance and calibration services as described in the statement of work (SOW).\nEast Orange Campus\nThe current Saniware Continuous Water Quality Monitoring panels (CWQM) and Sanikill Monochloramine Generator in East Orange have been subject to numerous over temperature environmental conditions over several years and are nearing the end of their life cycle.  To ensure compatibility and up to date technology the government wishes to upgrade these systems in the first year of the contract from the same manufacture to the most current configuration and materials of construction. (See basis of Design following)\nThe Contractor shall remove and replace the existing Sanipur Monochloramine generator with a new Sanikill Tec Model SKTEC - LT2010 along with all five (5) Saniware CWQM panels as per the schedule in the SOW.  Monthly Testing, Calibration, Reporting and Preventative Maintenance services of the Monochloramine generators and Saniware CWQM panels, including supply and delivery of chemical reagents, probes, parts, labor and associated services are part of the performance requirements throughout the period of the contract. \n\nLyons Campus\nThe current CWQM panels and Monochloramine Generators units at Lyons Campus have not been subject to overtemperature environmental conditions and are operating reliably currently. The contractor will be required to continue to operate and maintain these units. To ensure compatibility, the government wishes to upgrade these systems over five years of the contract term by removing and replacing the monochloramine Generators and the CWQM panels to the most current configuration and materials of construction. (See the Basis of Design following). The contractor will upgrade one Building with existing Monochloramine Generators and CWQM panels each year over the term of the contract.\n\nThere are currently Five (5) Sanipur Monochloramine Generators for supplemental water treatment, serving all the domestic water entering the buildings and five (5) Dual (hot & cold water) CWQM on the Lyons campus, one each in buildings 7, 53, 57, 135 and 143. \n\n\nBASIS OF DESIGN\nMonochloramine Generator - 1,000 grams/hour\n\nSYSTEM DESCRIPTION\nThe monochloramine system shall be a complete packaged unit to include both the monochloramine generator and the reagent dosing tanks. The water shall be fed to the reactor chamber by a recirculation pump supplied with the system. Reagent chemical addition shall be by electromagnetic membrane pumps which are synchronized to reach the optimum mixing rate in the reactor chamber. The dosing pumps shall feed the precursors subsequently with a delay (Delta T) that is automatically calculated by the electronic controller. The monochloramine shall be produced and exit the reactor within the water flow, which is then introduced in the water in direct proportion to flow and Oxidation Reduction Potential (ORP). An ORP probe placed on a recirculation sampling loop shall act to control the level of monochloramine by adjusting the dosage to maintain it in the specified range. The whole monochloramine generator assembly shall be an NSF/ANSI Standard 61 certified drinking water component. NSF/ANSI Standard 61 certification of individual components in contact with drinking water will not be accepted.  \n\nPERFORMANCE REQUIREMENTS\nElectronic Control Unit\nThe system shall be controlled by a single electronic PLC or microprocessor control unit. The controller will have a single screen to display all aspects of the operation of the system. A single keypad shall provide access to the control parameters.\n\n2) Connection to Building Automation Systems.\n BAS Connection   provide interface for the Building Automation System to monitor operation, set points, status indicators, and alarms via ModBus/TCP, Modbus RTU and BACnet. Connection to BAS is by the facility or their BAS contractor.\n\n      Dosing Pump Flow/Level Sensors\nThe system shall be equipped with flow sensors in each reagent dosing pump discharge to avoid improper mixing of the reagents. A flow fault switch will alarm the system to low or lack of water flow to the pre-dilution flow assembly and disable the system and send an alarm notification via the Building Automation System.\nThe unit shall be equipped with four level sensors for reagent tanks (two minimum level switches + two empty level switches).\n      Predilution flow sensors\nThe system shall have a stainless-steel pre-dilution flow meter to input to the microprocessor to maintain proper synchronization of the reagent pumps and insure accurate mixing of reagents. The pre-dilution flow meter shall be capable of measuring the flowrate in gpm and cfm, water velocity in ft/s and water temperature. The pre-dilution water meter shall be capable of outputting a programmable 4-20 mA analog output proportional to the water flow. The pre-dilution water meter shall also be capable of outputting a dry contact switch for high and low flow alarm.\n      3) Reagent Chemicals\nThe reagents chemicals shall be NSF/ANSI Standard 60 certified drinking water additives and so certified by The National Sanitation Foundation (NSF). Products certified by other third-party certifications agencies are not acceptable. The Chlorine source reagent chemical shall be a minimum 10% solution manufactured from a high purity, electrochemically produced and pH stabilized sodium hypochlorite. Total metals shall be less than 1% and pH shall be properly adjusted to maintain maximum stability after delivery. The Ammonia source reagent chemical shall be a maximum 19% ammonium chloride manufactured from food grade ammonium chloride to ensure stability and safe handling or a maximum 40% ammonium sulfate. Reagent chemicals shall be manufactured locally under license by the monochloramine equipment manufacturer to ensure compatibility and proper selection for the system. Chemical shall be supplied, delivered and applied only by manufactures authorized distributor.\n4) Reagent dosing pumps\nReagent dosing pumps shall be precision metering pumps capable of   accuracy + or   0.1 ml/min. Pump shall feature a stroke length only adjustment to avoid the possibility of frequency or input changes. Liquid end assemblies shall have acrylic heads with all Teflon diaphragms. Check valve assemblies are to be Teflon with Viton or Teflon O-rings and ceramic check balls. \n\n\n\n5) Corrosion Inhibitor Feed Option\nThe monochloramine generator unit shall be capable of automatically dosing a corrosion inhibitor based on system water flow and control shall be accomplished by the same unit as the monochloramine addition. Separate corrosion feed control sources shall not be acceptable.\n MANUAL VALVES\n1) Monochloramine unit reactor or predilution flow assembly\nPVDF, true union ball valves, Viton or Teflon O-ring, welded or threaded.2) Sample Valve, Product Water Sample Valve\nPVDF needle valves with Viton seats and seals.\nPIPING\n 1) Unit Predilution flow Assembly\nSchd. 80 PVDF, DN20 mm or DN25 mm with socket welded connections.\n            2) Field Piping from unit to point of injection:\n      All: Schd. 80 PVC, C-PVC or PVDF socket glued or welded\n\n\nCONTROLS\n1) Electronic PLC or microprocessor controller\nThe electronic PLC or the microprocessor shall provide automatic control for all operating functions. NEMA 4. All the wiring factory-installed and tested. Comply with Section 26Â 05Â 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) and NFPA 70.\n2) Alarm indicator and silence button.\nWarning Alarms: improper reagent feed, minimum reagent level, analysis flow fault. \nAutomatic Shutdown and Alarm: regent flow fault, empty reagent tank, loss of predilution flow, reading Error (loss of input signal).\n3) Status Indicators\nThe Controller operating screen shall display the following functions during normal operation\nRegent pump flow validation \nORP and Free/Total chlorine reading\nOperating Mode\nDelta time differential of reagents pumps stroke\nWater flow rate\nMonochloramine production rate in grams/hr.\nMonochloramine set point\nWater or enclosure ambient temperature\n\nINSTRUMENTATIONS AND DISPLAY\nAll instrumentation readouts panel-mounted in FRP enclosures rated NEMA All factory wiring. Comply with NFPA 70.\nFlow indicators for water reactor flow rate.\nFlow indicators for reagent lines.\nOne (1) ORP indicator measuring water quality with digital displays, alarm relays and automatic temperature compensation.\nTwo (2) chlorine residual sensors (free and/or total).\nOne (1) water meter input signal.\nOne (1) pre-dilution water meter signal.\nTwo (2) analog reagent tank levels inputs.\nOne (1) pH sensor.\nThree (3) analog 4-20 mA outputs\nTwelve (12) digital dry contact outputs\nTotal of fifteen (15) digital dry contact inputs\nModbus RTU.\nModbus/TCP interface for the Building Automation System to read and record information\nAbility to convert Modbus/TCP to BACnet/IP\n\n\n\nBASIS OF DESIGN\nContinuous Water Quality Monitoring Panels (CWQM) \n\nSYSTEM DESCRIPTION\nThe multi I/O continuous water quality monitor panels shall be capable of measuring system conductivity, pH, temperature, pressure, turbidity and oxidant levels (ORP/free chlorine/total chlorine). The conductivity sensors shall be an electrodeless style. All sensors shall have integral signal conditioning. Additional inputs shall include a flow switch, fifteen digital inputs, ten 4-20 mA inputs, eight inputs for pH and/or ORP probes, four inputs for conductivity sensors and five inputs for temperature probes.  Outputs shall include twelve digital dry contact switches and three 4-20 mA outputs. Digital communications shall be via USB, Ethernet, Modbus RTU and/or optional modem. All the controllers shall be networked together over Ethernet and shall be monitored from the same online page. Integration with DCS, SCADA system or building energy management systems shall be possible using the optional Modbus TCP/IP or Modbus RTU or BACnet IP feature. The controller shall be accessible via the Internet for configuring, data logging, and controlling digital outputs. The controller shall provide notification of alarm conditions via dry contact closure, text message and/or email. All water quality parameters shall be data logged in real time (24/7) and the data logs provided to the user as raw and visualized data.  The data must be stored online with no time limitations. The water quality monitor system shall be capable of accommodating one or two manifolds (pre-dilution loop/s) on the same panel. Each manifold shall be equipped with inline pH, ORP, Conductivity, Temperature, Turbidity and Pressure sensors. Cold water shall have total chlorine probes. All the probes from either the single or double manifold must be pre-wired to the same electronic controller. The whole water quality monitor system shall be NSF/ANSI Standard 61 certified drinking water components. NSF/ANSI Standard 61 of the single components in contact with drinking water will not be accepted.\n\nELECTRONIC CONTROLLER\n1) Electronic Control Unit\nThe system shall be controlled by a single electronic PLC or microprocessor control unit. Backlit LCD Graphics Module display shall indicate the process values, and the status of outputs and alarms. The controller will have a single screen to display all aspects of the operation of the system. A keypad shall provide access to the control parameters.\nBAS Connection   provide ModBus/TCP/RTU or BACnet interface for the Building Automation System to monitor operation, set points, status indicators, and alarms.\nThree levels of access codes shall be available to protect all set points and calibrations, while allowing the user to view any set point.\nMANUAL VALVES AND MATERIALS\n1) Water quality monitoring panel or predilution flow assembly\n PVDF, true union ball valves, Viton or Teflon O-ring, socket welded.\n2) Sample Valve, Product Water Sample Valve\n PVDF needle valves with Viton seats and seals.\n\nPIPING\n1) Water quality monitoring panel\nPVDF, DN20 mm or DN25 mm with Â¾  NPT or socket welded \n2) Field Piping from panel to main water system:\nAll: Schd. 80 PVC, C-PVC or PVDF socket glued\n\nCONTROL MODULE AND INTERLOCKS\n1) Electronic PLC or microprocessor controller\nThe electronic PLC or the microprocessor shall provide automatic control for all operating functions. NEMA 4. All the wiring factory-installed and tested. Comply with Section 26Â 05Â 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) and NFPA 70.\nPower requirements: 100-240 VAC Â± 10%, 50/60 Hz\n2) Alarm indicator and silence button.\nWarning Alarms: high/low values, no water flow through the panel, no water flow through the free and/or total chlorine housing\n3) Status Indicators\nThe Controller operating screen shall display the following functions during normal operation\nThree water quality parameters per page, operator can scroll pages up and down with the up/down arrows\nLow and high alarm for each parameter\nInterlock (if any) of each parameter\nDigital/analog output repetition (if any) of each parameter\n4) Interlocks\nThe controller shall be capable of interlocking any 4-20 mA input with a dry contact digital output to control and external device (drain valve, dosing pump) proportionally.\n5) Drain valve\nThe controller shall have the capability to operate an onboard drain valve with a timer. The timer shall allow operators to set a minimum of four daily drain events. External timers and drain systems will not be accepted.\n\nINPUTS\nFlow switch (up to three flow switches: water quality monitoring panel, free chlorine probe housing, total chlorine probe housing)\nDigital Inputs (1-15) Isolated dry contact dry contact, Namur.\nAnalog Inputs (1-10) 4-20 mA: 2-wires, configurable active (internally powered by 24 VDC) or passive (powered by externa device). Analog inputs shall be configured to accept external 4-20 mA reading\nORP Sensors (8) or pH sensors (8)\nConductivity (4) sensors\nTemperature (5) sensors\n\nOUTPUTS\nTwelve (12) dry contact switches\nThree analog outputs shall be, 4-20 mA: Isolated, 500-ohm maximum resistive load, internally powered\n\nSOFTWARE FEATURES\nThe water quality monitor software shall:\nSelf-tests shall be available to verify the integrity of the control module s sensor input circuitry.\nAn online reminder for electrode calibration shall be available.\nEach sensor input shall feature a two-point calibration.\nThe analog inputs shall be configurable for level sensors, corrosion monitors, or any other type of transmitter, providing appropriate units of measure and scaling.\nThe optional digital inputs shall be configurable for level switches, verification switches or generic interlock operation.\nStatus reports and data files shall be sent automatically via email on either a cyclical basis or for a specific date range. The date range can be adjusted by the operators and can be changed at any time.\nThe controller configuration may be entered by downloading them from one controller and uploading them into another controller via USB or remotely.\nAccess to the controller shall be possible using a USB connection, Ethernet, direct modem-to-modem, via the Internet, or via the local display and keypad, simultaneously if desired.\nNo proprietary software shall be required on the user s computer to communicate with the controller, or to view or change configuration.\nThe controller software shall be able to be upgraded remotely via the Internet.\nThe software must allow onsite data logging via USB with configurable time intervals.\n\nSENSORS / PROBES\nORP\nMaterials of construction: Glass, PVC\nProcess connections: PG 13.5  Â½ \nTemperature range: +23F - +190 F, -5C to +90 C\nPressure range: 0-100 psi (inline) 0-215 PSI (flow discharge)\nMeasure range: -1,000 mV - + 1,000 mV\nAccuracy: Â± 1 mV\npH\nMaterials of construction: Glass, PVC\nProcess connections: PG 13.5  Â½ \nTemperature range: +32F to +175F, -5C to +80 C\nPressure range: 0-100 psi (inline) 0-215 PSI (flow discharge)\nMeasure range: - 0 pH -  +14 pH\nAccuracy: Â± 0.1 pH\nPre-dilution flow sensor\nMaterials of construction: stainless steel\nDigital readout: programmable digital readout to display water flow (gpm/cfu), temperature and water velocity (ft/s)\nAnalog outputs: minimum one 4-20 mA to retransmit any value\nDigital outputs: dry contact switch for min and max flow alarm\nTemperature range: -4 F   194 F\nPressure range: 0   1,450 psi\nAccuracy: Â± 0.1 gpm, Â± 0.1 F\nFree Chlorine (option add)\nMaterials of construction: PVC, PMMA (probe holder)\nProcess connections: probe holder inlet/outlet 3/8 \nTemperature range: +32F to +120 F, 0C to +49 C\nPressure range: 0-14 psi\nMeasure range: 0 ppm -  +10 ppm\nAccuracy: Â± 0.1 ppm\nTotal Chlorine (option add)\nMaterials of construction: PVC, PMMA (probe holder)\nProcess connections: probe holder inlet/outlet 3/8 \nTemperature range: +32F to +120 F, 0C to +49 C\nPressure range: 0-14 psi\nMeasure range: 0 ppm -  +10 ppm\nAccuracy: Â± 0.1 ppm\nPressure\nMaterials of construction: stainless steel\nProcess connections: Â½ \nTemperature range: -4F to 257F -5C to +125 C\nPressure range: 0 - 280 psi (measure accuracy is guaranteed up to 140 PSI)\nMeasure range: 0 - 140 psi\nAccuracy: Â± 0.25% of maximum measure (0.35 PSI)\nConductivity\nMaterials of construction: stainless steel\nProcess connections: Â¾ \nTemperature range: +32F to +266F 0C to +130 C\nPressure range: 0 - 217 psi\nMeasure range: 0   20,000 mS\nAccuracy: Â± 1 mS\nTemperature\nMaterials of construction: stainless steel\nProcess connections: Â½ \nTemperature range: -58F to +500F -50C to +260C\nPressure range: 0 - 725 psi\nMeasure range: -58F to +500F -50C to +260C\nAccuracy: Â± 0.1F\n\nSENSORS / PROBES CALIBRATION\nA. The electrodeless conductivity sensor calibration shall be a two-point calibration (in air and at the process value), or a single point process calibration.\nB.   The ORP electrode calibration shall be a two-point calibration utilizing standard ORP buffer solutions\nC. The pH electrode calibration shall be a two-point calibration utilizing standard pH buffer solutions\nD. The total and/or free chlorine electrode calibration shall be two-point calibrations with zero-point calibration utilizing clean, oxidizer-free water and second point process calibration utilizing a DPD test.\n\n\n\nCOMMUNICATION AND DATALOG\nCommunication\nThe water quality monitor shall include an embedded web server utilizing standard BACnet IP, Modbus TCP/IP and Modbus RTU communications. \nRemote communications can be established via the Internet or on a direct line with modem-to-modem capability. \nMultiple users can access the controller simultaneously.\nThe water quality monitor shall have the capability of communicating with other water quality monitors in a master/slave configuration\nModbus TCP/IP client connectivity shall be standard\nData log\nThe water quality monitor shall data log all water quality parameters. Data recording frequency can be changed to once per day to every second. \nWater quality reporting feature shall be cloud-based to provide out of limit alarms via email or text, in real-time, to alert site operators of abnormal or dangerous conditions immediately  \nController data storage shall not expire. Data must be recorded 24/7 - 365 days per year with no storage limits.\nOut of limit alarms shall be generated in real-time\n1. Alarms and emails are generated in real-time as operator logs and service reports are recorded\n2. Alarms are in plain text message format to ensure compatibility with all devices\nThe reporting software shall have the following capabilities\nTrending wet test data against controller data\nStoring controller data with no storage limitations\nAutomatically emailing and text notifications reports\nProvide data visualizations for fast and easy identification of alarm conditions including green, yellow, and red colored alarms\nAll the controllers shall be accessible remotely from the same platform (one website) with a unique log in username and password. Single username and password for each individual controller shall not be accepted.\nAll the controllers shall be available from a main dashboard\nThe main dashboard shall show the main status of each controller (ON/OFF/ALARM)\nOperators can access each single controller from the main dashboard and then return to the main dashboard.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nSite\n Existing System Type\nQuantity\nLocation\n\n\n\n\nEast Orange Campus\nSanikill Generator Model #SKLP-800\n 1\nBldg. 1\nLyons Campus\nSanikill Generator Model #SKLP-150\n5\nBldg. 7, 53, 57,\n135,143\nEast Orange Campus\nSaniware Single CWQM+MonoS\n2\n\n.\nBldg. 1/8-3 & Penthouse\nÂ·East Orange\nCampus\nSaniware Dual CWQM+MonoS\n3\nBldg. 1, 2, 15\nLyons Campus \nSaniware Dual CWQM+MonoS\n5\nBldg. 7, 53: 57,\n135,143\n\nJ\n\n\n\n\n\nMaintenance & Service Schedule\n\nServices  \nMonthly\nQuarterly\nAnnually\nOn site Water Analysis & Reporting\nX\n\n\nReview of Operator Logs\nX\n\n\nClean & Calibrate Probes\nX\n,\n\n\nInventory Control & Order Entry\nX\n\n\nAdjust Chemical Application Levels\nX\n\n\nProbe & Pump Calibrations\n\nX\n\nComplete Wetted parts overhaul & test\n\n\nX\nOperator Training\n\n\nX\n\nAuthorized Service Kits and Parts\n\nSystem\nParts # / Description\nQuantity\nFrequency\nSanikill SKLP 800\nKSKLP 800 Maintenance kit\n1\nAnnual\nSanikill SKLP 150\nKSKLP 150 Maintenance kit\n5\nAnnual\nSaniware CWQM\nCS676HTTC SS  Probe (hot)\n9\n\n-\nAs needed\nSaniware CWQM\n190984-05 Cond/temp Probes (cold)\n8\nAs needed\nSaniware CWQM\nS800 CR pH Probe\n16\nAs needed\nSaniware CWQM\nPX-209-300G5 Pressure Transmitter\n16\nAs needed\nSaniware CWQM\nWTCB-20 19199 Total chlorine probe\n8\nAs needed\nSaniware CWQM\nWELMVR-22 ORP Probe\n8\nAs needed\n\n\nPerformance Period: [firm-F1xed-Pnce] (CO). Work hours are between 7:00am and 4:30 pm on normal weekdays. Work on Federal Holidays is excluded from this contract.\n5. Type of Contract: Firm-Fixed-Price.\nÂ·s. GENERAL REQUIREMENTS\n- Upon Completion ensure that all debris is cleaned up and removed from VA premises by contractor.\n\nC. SPECIFIC MANDATORY TASKS AND ASSOCIATED DELIVERABLES,\n\nContractor will follow all VA, OSHA, and EPA safety policies. The contractor shall supply all certifications and specifications of compliance with contract requirements as part of their response to solicitation. \n\nAll repairs will be inspected by a VA contracting Officers Representative.\nD. CHANGES TO STATEMENT OF WORK\n\nAny changes to this SOW shall be authorized and approved only through written correspondence from the CO.","text":"J046 Maintenance Repair, and Rebuilding of Equipment Water Purification and Sewage Treatment Equipment\nSOL:Â 36C24225Q0492\nDUE: May 20, 2025, at 10:00 AM EST.Â Â Â Â Â Â Â Â\nSET ASIDE: N/AÂ Â Â Â Â Â Â Â Â Â Â Â Â\nNAICS: 325998 All Other Miscellaneous Chemical Product and Preparation Manufacturing.\nPOP: 12-month Base Year with 4 option years.\nAGENCY:Â New Jersey VA Healthcare System\nPOC:Â Natalie Acevedo, email Natalie.Acevedo@va.gov Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â\nDESCRIPTION: NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT TO Klenzoid, Inc.Â\nMarket research was conducted and determined that Klenzoid, Inc.is the only vendor capable of meeting the requirement at New Jersey VAHCS.\nThis Notice of Intent is not a request for Proposals or Quotations.Â No solicitation document exists, and no telephone or email inquiries will be accepted.Â Â Â Â Â Â Â Â\nNo contract award will be made based on proposals, or quotations received in response to this notice.Â Â Â Â Â Â Â Â\nThe government MAY consider all Expressions of Interest (EOI) received prior to May 20,2025. Â\nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government.Â\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement.Â Â\nResponses to this notice must be emailed to Natalie.Acevedo@va.gov and received by 10:00 AM EST on May 20, 2025.Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â\nSubmitters are responsible for ensuring their EOI reaches the designated contracting officer on-time.Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â\nSee attached Statement of Work below for additional details.Â Â Â Â Â\nIf you have any questions or concerns, please contact me.\n\nSTATEMENT OF WORK\n\nA. GENERAL INFORMATION\n\nTitle of Project: Supplemental Disinfection and Continuous Water Quality Monitoring\nBackground: Per VA Directive 1061- Prevention of Healthcare Associated Legionnaires Disease and Scald Injury from Potable Water Distribution Systems, the VANJHCS Lyons & East Orange, NJ campus VA Medical Centers requires Supplemental Disinfection and Continuous Water Quality Monitoring. VANJHCS wishes to continue to lease Monochloramine Supplemental Disinfection systems and provide for the continued operation, maintenance and remote monitoring of both the Monochloramine systems and the Continuous Water Quality Monitoring and Monochloramine Stabilizer Systems. The combined requirement in accordance with the statement of work (SOW) is to provide for the continued operation and upgrading of the existing Monochloramine Generators for supplemental disinfection including the supply and maintenance of the equipment, supply and delivery of National Sanitation FoundationÂ® certified chemical reagents, parts, and labor necessary for upgrading and the continued operation and maintenance, probe calibration and replacement (as required) of the Continuous Water Quality Monitoring(CWQM) panels in the domestic cold and hot water System in compliance with the current VA 1061 Directive .\nScope of Work: The contractor shall provide all Labor and Material necessary to provide and install the specified equipment and accomplish the continued maintenance and calibration services as described in the statement of work (SOW).\nEast Orange Campus\nThe current Saniware Continuous Water Quality Monitoring panels (CWQM) and Sanikill Monochloramine Generator in East Orange have been subject to numerous over temperature environmental conditions over several years and are nearing the end of their life cycle. To ensure compatibility and up to date technology the government wishes to upgrade these systems in the first year of the contract from the same manufacture to the most current configuration and materials of construction. (See basis of Design following)\nThe Contractor shall remove and replace the existing Sanipur Monochloramine generator with a new Sanikill Tec Model SKTEC - LT2010 along with all five (5) Saniware CWQM panels as per the schedule in the SOW. Monthly Testing, Calibration, Reporting and Preventative Maintenance services of the Monochloramine generators and Saniware CWQM panels, including supply and delivery of chemical reagents, probes, parts, labor and associated services are part of the performance requirements throughout the period of the contract.\n\nLyons Campus\nThe current CWQM panels and Monochloramine Generators units at Lyons Campus have not been subject to overtemperature environmental conditions and are operating reliably currently. The contractor will be required to continue to operate and maintain these units. To ensure compatibility, the government wishes to upgrade these systems over five years of the contract term by removing and replacing the monochloramine Generators and the CWQM panels to the most current configuration and materials of construction. (See the Basis of Design following). The contractor will upgrade one Building with existing Monochloramine Generators and CWQM panels each year over the term of the contract.\n\nThere are currently Five (5) Sanipur Monochloramine Generators for supplemental water treatment, serving all the domestic water entering the buildings and five (5) Dual (hot & cold water) CWQM on the Lyons campus, one each in buildings 7, 53, 57, 135 and 143.\n\nBASIS OF DESIGN\nMonochloramine Generator - 1,000 grams/hour\n\nSYSTEM DESCRIPTION\nThe monochloramine system shall be a complete packaged unit to include both the monochloramine generator and the reagent dosing tanks. The water shall be fed to the reactor chamber by a recirculation pump supplied with the system. Reagent chemical addition shall be by electromagnetic membrane pumps which are synchronized to reach the optimum mixing rate in the reactor chamber. The dosing pumps shall feed the precursors subsequently with a delay (Delta T) that is automatically calculated by the electronic controller. The monochloramine shall be produced and exit the reactor within the water flow, which is then introduced in the water in direct proportion to flow and Oxidation Reduction Potential (ORP). An ORP probe placed on a recirculation sampling loop shall act to control the level of monochloramine by adjusting the dosage to maintain it in the specified range. The whole monochloramine generator assembly shall be an NSF/ANSI Standard 61 certified drinking water component. NSF/ANSI Standard 61 certification of individual components in contact with drinking water will not be accepted.\n\nPERFORMANCE REQUIREMENTS\nElectronic Control Unit\nThe system shall be controlled by a single electronic PLC or microprocessor control unit. The controller will have a single screen to display all aspects of the operation of the system. A single keypad shall provide access to the control parameters.\n\n2) Connection to Building Automation Systems.\nBAS Connection provide interface for the Building Automation System to monitor operation, set points, status indicators, and alarms via ModBus/TCP, Modbus RTU and BACnet. Connection to BAS is by the facility or their BAS contractor.\n\nDosing Pump Flow/Level Sensors\nThe system shall be equipped with flow sensors in each reagent dosing pump discharge to avoid improper mixing of the reagents. A flow fault switch will alarm the system to low or lack of water flow to the pre-dilution flow assembly and disable the system and send an alarm notification via the Building Automation System.\nThe unit shall be equipped with four level sensors for reagent tanks (two minimum level switches + two empty level switches).\nPredilution flow sensors\nThe system shall have a stainless-steel pre-dilution flow meter to input to the microprocessor to maintain proper synchronization of the reagent pumps and insure accurate mixing of reagents. The pre-dilution flow meter shall be capable of measuring the flowrate in gpm and cfm, water velocity in ft/s and water temperature. The pre-dilution water meter shall be capable of outputting a programmable 4-20 mA analog output proportional to the water flow. The pre-dilution water meter shall also be capable of outputting a dry contact switch for high and low flow alarm.\n3) Reagent Chemicals\nThe reagents chemicals shall be NSF/ANSI Standard 60 certified drinking water additives and so certified by The National Sanitation Foundation (NSF). Products certified by other third-party certifications agencies are not acceptable. The Chlorine source reagent chemical shall be a minimum 10% solution manufactured from a high purity, electrochemically produced and pH stabilized sodium hypochlorite. Total metals shall be less than 1% and pH shall be properly adjusted to maintain maximum stability after delivery. The Ammonia source reagent chemical shall be a maximum 19% ammonium chloride manufactured from food grade ammonium chloride to ensure stability and safe handling or a maximum 40% ammonium sulfate. Reagent chemicals shall be manufactured locally under license by the monochloramine equipment manufacturer to ensure compatibility and proper selection for the system. Chemical shall be supplied, delivered and applied only by manufactures authorized distributor.\n4) Reagent dosing pumps\nReagent dosing pumps shall be precision metering pumps capable of accuracy + or 0.1 ml/min. Pump shall feature a stroke length only adjustment to avoid the possibility of frequency or input changes. Liquid end assemblies shall have acrylic heads with all Teflon diaphragms. Check valve assemblies are to be Teflon with Viton or Teflon O-rings and ceramic check balls.\n\n5) Corrosion Inhibitor Feed Option\nThe monochloramine generator unit shall be capable of automatically dosing a corrosion inhibitor based on system water flow and control shall be accomplished by the same unit as the monochloramine addition. Separate corrosion feed control sources shall not be acceptable.\nMANUAL VALVES\n1) Monochloramine unit reactor or predilution flow assembly\nPVDF, true union ball valves, Viton or Teflon O-ring, welded or threaded.2) Sample Valve, Product Water Sample Valve\nPVDF needle valves with Viton seats and seals.\nPIPING\n1) Unit Predilution flow Assembly\nSchd. 80 PVDF, DN20 mm or DN25 mm with socket welded connections.\n2) Field Piping from unit to point of injection:\nAll: Schd. 80 PVC, C-PVC or PVDF socket glued or welded\n\nCONTROLS\n1) Electronic PLC or microprocessor controller\nThe electronic PLC or the microprocessor shall provide automatic control for all operating functions. NEMA 4. All the wiring factory-installed and tested. Comply with Section 26Â 05Â 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) and NFPA 70.\n2) Alarm indicator and silence button.\nWarning Alarms: improper reagent feed, minimum reagent level, analysis flow fault.\nAutomatic Shutdown and Alarm: regent flow fault, empty reagent tank, loss of predilution flow, reading Error (loss of input signal).\n3) Status Indicators\nThe Controller operating screen shall display the following functions during normal operation\nRegent pump flow validation\nORP and Free/Total chlorine reading\nOperating Mode\nDelta time differential of reagents pumps stroke\nWater flow rate\nMonochloramine production rate in grams/hr.\nMonochloramine set point\nWater or enclosure ambient temperature\n\nINSTRUMENTATIONS AND DISPLAY\nAll instrumentation readouts panel-mounted in FRP enclosures rated NEMA All factory wiring. Comply with NFPA 70.\nFlow indicators for water reactor flow rate.\nFlow indicators for reagent lines.\nOne (1) ORP indicator measuring water quality with digital displays, alarm relays and automatic temperature compensation.\nTwo (2) chlorine residual sensors (free and/or total).\nOne (1) water meter input signal.\nOne (1) pre-dilution water meter signal.\nTwo (2) analog reagent tank levels inputs.\nOne (1) pH sensor.\nThree (3) analog 4-20 mA outputs\nTwelve (12) digital dry contact outputs\nTotal of fifteen (15) digital dry contact inputs\nModbus RTU.\nModbus/TCP interface for the Building Automation System to read and record information\nAbility to convert Modbus/TCP to BACnet/IP\n\nBASIS OF DESIGN\nContinuous Water Quality Monitoring Panels (CWQM)\n\nSYSTEM DESCRIPTION\nThe multi I/O continuous water quality monitor panels shall be capable of measuring system conductivity, pH, temperature, pressure, turbidity and oxidant levels (ORP/free chlorine/total chlorine). The conductivity sensors shall be an electrodeless style. All sensors shall have integral signal conditioning. Additional inputs shall include a flow switch, fifteen digital inputs, ten 4-20 mA inputs, eight inputs for pH and/or ORP probes, four inputs for conductivity sensors and five inputs for temperature probes. Outputs shall include twelve digital dry contact switches and three 4-20 mA outputs. Digital communications shall be via USB, Ethernet, Modbus RTU and/or optional modem. All the controllers shall be networked together over Ethernet and shall be monitored from the same online page. Integration with DCS, SCADA system or building energy management systems shall be possible using the optional Modbus TCP/IP or Modbus RTU or BACnet IP feature. The controller shall be accessible via the Internet for configuring, data logging, and controlling digital outputs. The controller shall provide notification of alarm conditions via dry contact closure, text message and/or email. All water quality parameters shall be data logged in real time (24/7) and the data logs provided to the user as raw and visualized data. The data must be stored online with no time limitations. The water quality monitor system shall be capable of accommodating one or two manifolds (pre-dilution loop/s) on the same panel. Each manifold shall be equipped with inline pH, ORP, Conductivity, Temperature, Turbidity and Pressure sensors. Cold water shall have total chlorine probes. All the probes from either the single or double manifold must be pre-wired to the same electronic controller. The whole water quality monitor system shall be NSF/ANSI Standard 61 certified drinking water components. NSF/ANSI Standard 61 of the single components in contact with drinking water will not be accepted.\n\nELECTRONIC CONTROLLER\n1) Electronic Control Unit\nThe system shall be controlled by a single electronic PLC or microprocessor control unit. Backlit LCD Graphics Module display shall indicate the process values, and the status of outputs and alarms. The controller will have a single screen to display all aspects of the operation of the system. A keypad shall provide access to the control parameters.\nBAS Connection provide ModBus/TCP/RTU or BACnet interface for the Building Automation System to monitor operation, set points, status indicators, and alarms.\nThree levels of access codes shall be available to protect all set points and calibrations, while allowing the user to view any set point.\nMANUAL VALVES AND MATERIALS\n1) Water quality monitoring panel or predilution flow assembly\nPVDF, true union ball valves, Viton or Teflon O-ring, socket welded.\n2) Sample Valve, Product Water Sample Valve\nPVDF needle valves with Viton seats and seals.\n\nPIPING\n1) Water quality monitoring panel\nPVDF, DN20 mm or DN25 mm with Â¾ NPT or socket welded\n2) Field Piping from panel to main water system:\nAll: Schd. 80 PVC, C-PVC or PVDF socket glued\n\nCONTROL MODULE AND INTERLOCKS\n1) Electronic PLC or microprocessor controller\nThe electronic PLC or the microprocessor shall provide automatic control for all operating functions. NEMA 4. All the wiring factory-installed and tested. Comply with Section 26Â 05Â 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) and NFPA 70.\nPower requirements: 100-240 VAC Â± 10%, 50/60 Hz\n2) Alarm indicator and silence button.\nWarning Alarms: high/low values, no water flow through the panel, no water flow through the free and/or total chlorine housing\n3) Status Indicators\nThe Controller operating screen shall display the following functions during normal operation\nThree water quality parameters per page, operator can scroll pages up and down with the up/down arrows\nLow and high alarm for each parameter\nInterlock (if any) of each parameter\nDigital/analog output repetition (if any) of each parameter\n4) Interlocks\nThe controller shall be capable of interlocking any 4-20 mA input with a dry contact digital output to control and external device (drain valve, dosing pump) proportionally.\n5) Drain valve\nThe controller shall have the capability to operate an onboard drain valve with a timer. The timer shall allow operators to set a minimum of four daily drain events. External timers and drain systems will not be accepted.\n\nINPUTS\nFlow switch (up to three flow switches: water quality monitoring panel, free chlorine probe housing, total chlorine probe housing)\nDigital Inputs (1-15) Isolated dry contact dry contact, Namur.\nAnalog Inputs (1-10) 4-20 mA: 2-wires, configurable active (internally powered by 24 VDC) or passive (powered by externa device). Analog inputs shall be configured to accept external 4-20 mA reading\nORP Sensors (8) or pH sensors (8)\nConductivity (4) sensors\nTemperature (5) sensors\n\nOUTPUTS\nTwelve (12) dry contact switches\nThree analog outputs shall be, 4-20 mA: Isolated, 500-ohm maximum resistive load, internally powered\n\nSOFTWARE FEATURES\nThe water quality monitor software shall:\nSelf-tests shall be available to verify the integrity of the control module s sensor input circuitry.\nAn online reminder for electrode calibration shall be available.\nEach sensor input shall feature a two-point calibration.\nThe analog inputs shall be configurable for level sensors, corrosion monitors, or any other type of transmitter, providing appropriate units of measure and scaling.\nThe optional digital inputs shall be configurable for level switches, verification switches or generic interlock operation.\nStatus reports and data files shall be sent automatically via email on either a cyclical basis or for a specific date range. The date range can be adjusted by the operators and can be changed at any time.\nThe controller configuration may be entered by downloading them from one controller and uploading them into another controller via USB or remotely.\nAccess to the controller shall be possible using a USB connection, Ethernet, direct modem-to-modem, via the Internet, or via the local display and keypad, simultaneously if desired.\nNo proprietary software shall be required on the user s computer to communicate with the controller, or to view or change configuration.\nThe controller software shall be able to be upgraded remotely via the Internet.\nThe software must allow onsite data logging via USB with configurable time intervals.\n\nSENSORS / PROBES\nORP\nMaterials of construction: Glass, PVC\nProcess connections: PG 13.5 Â½\nTemperature range: +23F - +190 F, -5C to +90 C\nPressure range: 0-100 psi (inline) 0-215 PSI (flow discharge)\nMeasure range: -1,000 mV - + 1,000 mV\nAccuracy: Â± 1 mV\npH\nMaterials of construction: Glass, PVC\nProcess connections: PG 13.5 Â½\nTemperature range: +32F to +175F, -5C to +80 C\nPressure range: 0-100 psi (inline) 0-215 PSI (flow discharge)\nMeasure range: - 0 pH - +14 pH\nAccuracy: Â± 0.1 pH\nPre-dilution flow sensor\nMaterials of construction: stainless steel\nDigital readout: programmable digital readout to display water flow (gpm/cfu), temperature and water velocity (ft/s)\nAnalog outputs: minimum one 4-20 mA to retransmit any value\nDigital outputs: dry contact switch for min and max flow alarm\nTemperature range: -4 F 194 F\nPressure range: 0 1,450 psi\nAccuracy: Â± 0.1 gpm, Â± 0.1 F\nFree Chlorine (option add)\nMaterials of construction: PVC, PMMA (probe holder)\nProcess connections: probe holder inlet/outlet 3/8\nTemperature range: +32F to +120 F, 0C to +49 C\nPressure range: 0-14 psi\nMeasure range: 0 ppm - +10 ppm\nAccuracy: Â± 0.1 ppm\nTotal Chlorine (option add)\nMaterials of construction: PVC, PMMA (probe holder)\nProcess connections: probe holder inlet/outlet 3/8\nTemperature range: +32F to +120 F, 0C to +49 C\nPressure range: 0-14 psi\nMeasure range: 0 ppm - +10 ppm\nAccuracy: Â± 0.1 ppm\nPressure\nMaterials of construction: stainless steel\nProcess connections: Â½\nTemperature range: -4F to 257F -5C to +125 C\nPressure range: 0 - 280 psi (measure accuracy is guaranteed up to 140 PSI)\nMeasure range: 0 - 140 psi\nAccuracy: Â± 0.25% of maximum measure (0.35 PSI)\nConductivity\nMaterials of construction: stainless steel\nProcess connections: Â¾\nTemperature range: +32F to +266F 0C to +130 C\nPressure range: 0 - 217 psi\nMeasure range: 0 20,000 mS\nAccuracy: Â± 1 mS\nTemperature\nMaterials of construction: stainless steel\nProcess connections: Â½\nTemperature range: -58F to +500F -50C to +260C\nPressure range: 0 - 725 psi\nMeasure range: -58F to +500F -50C to +260C\nAccuracy: Â± 0.1F\n\nSENSORS / PROBES CALIBRATION\nA. The electrodeless conductivity sensor calibration shall be a two-point calibration (in air and at the process value), or a single point process calibration.\nB. The ORP electrode calibration shall be a two-point calibration utilizing standard ORP buffer solutions\nC. The pH electrode calibration shall be a two-point calibration utilizing standard pH buffer solutions\nD. The total and/or free chlorine electrode calibration shall be two-point calibrations with zero-point calibration utilizing clean, oxidizer-free water and second point process calibration utilizing a DPD test.\n\nCOMMUNICATION AND DATALOG\nCommunication\nThe water quality monitor shall include an embedded web server utilizing standard BACnet IP, Modbus TCP/IP and Modbus RTU communications.\nRemote communications can be established via the Internet or on a direct line with modem-to-modem capability.\nMultiple users can access the controller simultaneously.\nThe water quality monitor shall have the capability of communicating with other water quality monitors in a master/slave configuration\nModbus TCP/IP client connectivity shall be standard\nData log\nThe water quality monitor shall data log all water quality parameters. Data recording frequency can be changed to once per day to every second.\nWater quality reporting feature shall be cloud-based to provide out of limit alarms via email or text, in real-time, to alert site operators of abnormal or dangerous conditions immediately\nController data storage shall not expire. Data must be recorded 24/7 - 365 days per year with no storage limits.\nOut of limit alarms shall be generated in real-time\n1. Alarms and emails are generated in real-time as operator logs and service reports are recorded\n2. Alarms are in plain text message format to ensure compatibility with all devices\nThe reporting software shall have the following capabilities\nTrending wet test data against controller data\nStoring controller data with no storage limitations\nAutomatically emailing and text notifications reports\nProvide data visualizations for fast and easy identification of alarm conditions including green, yellow, and red colored alarms\nAll the controllers shall be accessible remotely from the same platform (one website) with a unique log in username and password. Single username and password for each individual controller shall not be accepted.\nAll the controllers shall be available from a main dashboard\nThe main dashboard shall show the main status of each controller (ON/OFF/ALARM)\nOperators can access each single controller from the main dashboard and then return to the main dashboard.\n\nSite\nExisting System Type\nQuantity\nLocation\n\nEast Orange Campus\nSanikill Generator Model #SKLP-800\n1\nBldg. 1\nLyons Campus\nSanikill Generator Model #SKLP-150\n5\nBldg. 7, 53, 57,\n135,143\nEast Orange Campus\nSaniware Single CWQM+MonoS\n2\n\n.\nBldg. 1/8-3 & Penthouse\nÂ·East Orange\nCampus\nSaniware Dual CWQM+MonoS\n3\nBldg. 1, 2, 15\nLyons Campus\nSaniware Dual CWQM+MonoS\n5\nBldg. 7, 53: 57,\n135,143\n\nJ\n\nMaintenance & Service Schedule\n\nServices\nMonthly\nQuarterly\nAnnually\nOn site Water Analysis & Reporting\nX\n\nReview of Operator Logs\nX\n\nClean & Calibrate Probes\nX\n,\n\nInventory Control & Order Entry\nX\n\nAdjust Chemical Application Levels\nX\n\nProbe & Pump Calibrations\n\nX\n\nComplete Wetted parts overhaul & test\n\nX\nOperator Training\n\nX\n\nAuthorized Service Kits and Parts\n\nSystem\nParts # / Description\nQuantity\nFrequency\nSanikill SKLP 800\nKSKLP 800 Maintenance kit\n1\nAnnual\nSanikill SKLP 150\nKSKLP 150 Maintenance kit\n5\nAnnual\nSaniware CWQM\nCS676HTTC SS Probe (hot)\n9\n\n-\nAs needed\nSaniware CWQM\n190984-05 Cond/temp Probes (cold)\n8\nAs needed\nSaniware CWQM\nS800 CR pH Probe\n16\nAs needed\nSaniware CWQM\nPX-209-300G5 Pressure Transmitter\n16\nAs needed\nSaniware CWQM\nWTCB-20 19199 Total chlorine probe\n8\nAs needed\nSaniware CWQM\nWELMVR-22 ORP Probe\n8\nAs needed\n\nPerformance Period: [firm-F1xed-Pnce] (CO). Work hours are between 7:00am and 4:30 pm on normal weekdays. Work on Federal Holidays is excluded from this contract.\n5. Type of Contract: Firm-Fixed-Price.\nÂ·s. GENERAL REQUIREMENTS\n- Upon Completion ensure that all debris is cleaned up and removed from VA premises by contractor.\n\nC. SPECIFIC MANDATORY TASKS AND ASSOCIATED DELIVERABLES,\n\nContractor will follow all VA, OSHA, and EPA safety policies. The contractor shall supply all certifications and specifications of compliance with contract requirements as part of their response to solicitation.\n\nAll repairs will be inspected by a VA contracting Officers Representative.\nD. CHANGES TO STATEMENT OF WORK\n\nAny changes to this SOW shall be authorized and approved only through written correspondence from the CO.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24225Q0492","product_service_code":"J046"}],"due_at":"2025-05-19T14:00:00Z","due_date":"2025-05-19","closes_at":"2025-05-19T14:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NJ","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"description","state_evidence":"BUTION SYSTEMS, THE VANJHCS LYONS & EAST ORANGE, NJ","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-15T03:04:09.668144Z","principal_notice_id":"a81d98a20d394f15a01d74d9538da17f","description":{"text":"J046 Maintenance Repair, and Rebuilding of Equipment Water Purification and Sewage Treatment Equipment\nSOL:Â 36C24225Q0492\nDUE: May 20, 2025, at 10:00 AM EST.Â Â Â Â Â Â Â Â\nSET ASIDE: N/AÂ Â Â Â Â Â Â Â Â Â Â Â Â\nNAICS: 325998 All Other Miscellaneous Chemical Product and Preparation Manufacturing.\nPOP: 12-month Base Year with 4 option years.\nAGENCY:Â New Jersey VA Healthcare System\nPOC:Â Natalie Acevedo, email Natalie.Acevedo@va.gov Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â\nDESCRIPTION: NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT TO Klenzoid, Inc.Â\nMarket research was conducted and determined that Klenzoid, Inc.is the only vendor capable of meeting the requirement at New Jersey VAHCS.\nThis Notice of Intent is not a request for Proposals or Quotations.Â No solicitation document exists, and no telephone or email inquiries will be accepted.Â Â Â Â Â Â Â Â\nNo contract award will be made based on proposals, or quotations received in response to this notice.Â Â Â Â Â Â Â Â\nThe government MAY consider all Expressions of Interest (EOI) received prior to May 20,2025. Â\nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government.Â\nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement.Â Â\nResponses to this notice must be emailed to Natalie.Acevedo@va.gov and received by 10:00 AM EST on May 20, 2025.Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â\nSubmitters are responsible for ensuring their EOI reaches the designated contracting officer on-time.Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â\nSee attached Statement of Work below for additional details.Â Â Â Â Â\nIf you have any questions or concerns, please contact me.\n\nSTATEMENT OF WORK\n\nA. GENERAL INFORMATION\n\nTitle of Project: Supplemental Disinfection and Continuous Water Quality Monitoring\nBackground: Per VA Directive 1061- Prevention of Healthcare Associated Legionnaires Disease and Scald Injury from Potable Water Distribution Systems, the VANJHCS Lyons & East Orange, NJ campus VA Medical Centers requires Supplemental Disinfection and Continuous Water Quality Monitoring. VANJHCS wishes to continue to lease Monochloramine Supplemental Disinfection systems and provide for the continued operation, maintenance and remote monitoring of both the Monochloramine systems and the Continuous Water Quality Monitoring and Monochloramine Stabilizer Systems. The combined requirement in accordance with the statement of work (SOW) is to provide for the continued operation and upgrading of the existing Monochloramine Generators for supplemental disinfection including the supply and maintenance of the equipment, supply and delivery of National Sanitation FoundationÂ® certified chemical reagents, parts, and labor necessary for upgrading and the continued operation and maintenance, probe calibration and replacement (as required) of the Continuous Water Quality Monitoring(CWQM) panels in the domestic cold and hot water System in compliance with the current VA 1061 Directive .\nScope of Work: The contractor shall provide all Labor and Material necessary to provide and install the specified equipment and accomplish the continued maintenance and calibration services as described in the statement of work (SOW).\nEast Orange Campus\nThe current Saniware Continuous Water Quality Monitoring panels (CWQM) and Sanikill Monochloramine Generator in East Orange have been subject to numerous over temperature environmental conditions over several years and are nearing the end of their life cycle. To ensure compatibility and up to date technology the government wishes to upgrade these systems in the first year of the contract from the same manufacture to the most current configuration and materials of construction. (See basis of Design following)\nThe Contractor shall remove and replace the existing Sanipur Monochloramine generator with a new Sanikill Tec Model SKTEC - LT2010 along with all five (5) Saniware CWQM panels as per the schedule in the SOW. Monthly Testing, Calibration, Reporting and Preventative Maintenance services of the Monochloramine generators and Saniware CWQM panels, including supply and delivery of chemical reagents, probes, parts, labor and associated services are part of the performance requirements throughout the period of the contract.\n\nLyons Campus\nThe current CWQM panels and Monochloramine Generators units at Lyons Campus have not been subject to overtemperature environmental conditions and are operating reliably currently. The contractor will be required to continue to operate and maintain these units. To ensure compatibility, the government wishes to upgrade these systems over five years of the contract term by removing and replacing the monochloramine Generators and the CWQM panels to the most current configuration and materials of construction. (See the Basis of Design following). The contractor will upgrade one Building with existing Monochloramine Generators and CWQM panels each year over the term of the contract.\n\nThere are currently Five (5) Sanipur Monochloramine Generators for supplemental water treatment, serving all the domestic water entering the buildings and five (5) Dual (hot & cold water) CWQM on the Lyons campus, one each in buildings 7, 53, 57, 135 and 143.\n\nBASIS OF DESIGN\nMonochloramine Generator - 1,000 grams/hour\n\nSYSTEM DESCRIPTION\nThe monochloramine system shall be a complete packaged unit to include both the monochloramine generator and the reagent dosing tanks. The water shall be fed to the reactor chamber by a recirculation pump supplied with the system. Reagent chemical addition shall be by electromagnetic membrane pumps which are synchronized to reach the optimum mixing rate in the reactor chamber. The dosing pumps shall feed the precursors subsequently with a delay (Delta T) that is automatically calculated by the electronic controller. The monochloramine shall be produced and exit the reactor within the water flow, which is then introduced in the water in direct proportion to flow and Oxidation Reduction Potential (ORP). An ORP probe placed on a recirculation sampling loop shall act to control the level of monochloramine by adjusting the dosage to maintain it in the specified range. The whole monochloramine generator assembly shall be an NSF/ANSI Standard 61 certified drinking water component. NSF/ANSI Standard 61 certification of individual components in contact with drinking water will not be accepted.\n\nPERFORMANCE REQUIREMENTS\nElectronic Control Unit\nThe system shall be controlled by a single electronic PLC or microprocessor control unit. The controller will have a single screen to display all aspects of the operation of the system. A single keypad shall provide access to the control parameters.\n\n2) Connection to Building Automation Systems.\nBAS Connection provide interface for the Building Automation System to monitor operation, set points, status indicators, and alarms via ModBus/TCP, Modbus RTU and BACnet. Connection to BAS is by the facility or their BAS contractor.\n\nDosing Pump Flow/Level Sensors\nThe system shall be equipped with flow sensors in each reagent dosing pump discharge to avoid improper mixing of the reagents. A flow fault switch will alarm the system to low or lack of water flow to the pre-dilution flow assembly and disable the system and send an alarm notification via the Building Automation System.\nThe unit shall be equipped with four level sensors for reagent tanks (two minimum level switches + two empty level switches).\nPredilution flow sensors\nThe system shall have a stainless-steel pre-dilution flow meter to input to the microprocessor to maintain proper synchronization of the reagent pumps and insure accurate mixing of reagents. The pre-dilution flow meter shall be capable of measuring the flowrate in gpm and cfm, water velocity in ft/s and water temperature. The pre-dilution water meter shall be capable of outputting a programmable 4-20 mA analog output proportional to the water flow. The pre-dilution water meter shall also be capable of outputting a dry contact switch for high and low flow alarm.\n3) Reagent Chemicals\nThe reagents chemicals shall be NSF/ANSI Standard 60 certified drinking water additives and so certified by The National Sanitation Foundation (NSF). Products certified by other third-party certifications agencies are not acceptable. The Chlorine source reagent chemical shall be a minimum 10% solution manufactured from a high purity, electrochemically produced and pH stabilized sodium hypochlorite. Total metals shall be less than 1% and pH shall be properly adjusted to maintain maximum stability after delivery. The Ammonia source reagent chemical shall be a maximum 19% ammonium chloride manufactured from food grade ammonium chloride to ensure stability and safe handling or a maximum 40% ammonium sulfate. Reagent chemicals shall be manufactured locally under license by the monochloramine equipment manufacturer to ensure compatibility and proper selection for the system. Chemical shall be supplied, delivered and applied only by manufactures authorized distributor.\n4) Reagent dosing pumps\nReagent dosing pumps shall be precision metering pumps capable of accuracy + or 0.1 ml/min. Pump shall feature a stroke length only adjustment to avoid the possibility of frequency or input changes. Liquid end assemblies shall have acrylic heads with all Teflon diaphragms. Check valve assemblies are to be Teflon with Viton or Teflon O-rings and ceramic check balls.\n\n5) Corrosion Inhibitor Feed Option\nThe monochloramine generator unit shall be capable of automatically dosing a corrosion inhibitor based on system water flow and control shall be accomplished by the same unit as the monochloramine addition. Separate corrosion feed control sources shall not be acceptable.\nMANUAL VALVES\n1) Monochloramine unit reactor or predilution flow assembly\nPVDF, true union ball valves, Viton or Teflon O-ring, welded or threaded.2) Sample Valve, Product Water Sample Valve\nPVDF needle valves with Viton seats and seals.\nPIPING\n1) Unit Predilution flow Assembly\nSchd. 80 PVDF, DN20 mm or DN25 mm with socket welded connections.\n2) Field Piping from unit to point of injection:\nAll: Schd. 80 PVC, C-PVC or PVDF socket glued or welded\n\nCONTROLS\n1) Electronic PLC or microprocessor controller\nThe electronic PLC or the microprocessor shall provide automatic control for all operating functions. NEMA 4. All the wiring factory-installed and tested. Comply with Section 26Â 05Â 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) and NFPA 70.\n2) Alarm indicator and silence button.\nWarning Alarms: improper reagent feed, minimum reagent level, analysis flow fault.\nAutomatic Shutdown and Alarm: regent flow fault, empty reagent tank, loss of predilution flow, reading Error (loss of input signal).\n3) Status Indicators\nThe Controller operating screen shall display the following functions during normal operation\nRegent pump flow validation\nORP and Free/Total chlorine reading\nOperating Mode\nDelta time differential of reagents pumps stroke\nWater flow rate\nMonochloramine production rate in grams/hr.\nMonochloramine set point\nWater or enclosure ambient temperature\n\nINSTRUMENTATIONS AND DISPLAY\nAll instrumentation readouts panel-mounted in FRP enclosures rated NEMA All factory wiring. Comply with NFPA 70.\nFlow indicators for water reactor flow rate.\nFlow indicators for reagent lines.\nOne (1) ORP indicator measuring water quality with digital displays, alarm relays and automatic temperature compensation.\nTwo (2) chlorine residual sensors (free and/or total).\nOne (1) water meter input signal.\nOne (1) pre-dilution water meter signal.\nTwo (2) analog reagent tank levels inputs.\nOne (1) pH sensor.\nThree (3) analog 4-20 mA outputs\nTwelve (12) digital dry contact outputs\nTotal of fifteen (15) digital dry contact inputs\nModbus RTU.\nModbus/TCP interface for the Building Automation System to read and record information\nAbility to convert Modbus/TCP to BACnet/IP\n\nBASIS OF DESIGN\nContinuous Water Quality Monitoring Panels (CWQM)\n\nSYSTEM DESCRIPTION\nThe multi I/O continuous water quality monitor panels shall be capable of measuring system conductivity, pH, temperature, pressure, turbidity and oxidant levels (ORP/free chlorine/total chlorine). The conductivity sensors shall be an electrodeless style. All sensors shall have integral signal conditioning. Additional inputs shall include a flow switch, fifteen digital inputs, ten 4-20 mA inputs, eight inputs for pH and/or ORP probes, four inputs for conductivity sensors and five inputs for temperature probes. Outputs shall include twelve digital dry contact switches and three 4-20 mA outputs. Digital communications shall be via USB, Ethernet, Modbus RTU and/or optional modem. All the controllers shall be networked together over Ethernet and shall be monitored from the same online page. Integration with DCS, SCADA system or building energy management systems shall be possible using the optional Modbus TCP/IP or Modbus RTU or BACnet IP feature. The controller shall be accessible via the Internet for configuring, data logging, and controlling digital outputs. The controller shall provide notification of alarm conditions via dry contact closure, text message and/or email. All water quality parameters shall be data logged in real time (24/7) and the data logs provided to the user as raw and visualized data. The data must be stored online with no time limitations. The water quality monitor system shall be capable of accommodating one or two manifolds (pre-dilution loop/s) on the same panel. Each manifold shall be equipped with inline pH, ORP, Conductivity, Temperature, Turbidity and Pressure sensors. Cold water shall have total chlorine probes. All the probes from either the single or double manifold must be pre-wired to the same electronic controller. The whole water quality monitor system shall be NSF/ANSI Standard 61 certified drinking water components. NSF/ANSI Standard 61 of the single components in contact with drinking water will not be accepted.\n\nELECTRONIC CONTROLLER\n1) Electronic Control Unit\nThe system shall be controlled by a single electronic PLC or microprocessor control unit. Backlit LCD Graphics Module display shall indicate the process values, and the status of outputs and alarms. The controller will have a single screen to display all aspects of the operation of the system. A keypad shall provide access to the control parameters.\nBAS Connection provide ModBus/TCP/RTU or BACnet interface for the Building Automation System to monitor operation, set points, status indicators, and alarms.\nThree levels of access codes shall be available to protect all set points and calibrations, while allowing the user to view any set point.\nMANUAL VALVES AND MATERIALS\n1) Water quality monitoring panel or predilution flow assembly\nPVDF, true union ball valves, Viton or Teflon O-ring, socket welded.\n2) Sample Valve, Product Water Sample Valve\nPVDF needle valves with Viton seats and seals.\n\nPIPING\n1) Water quality monitoring panel\nPVDF, DN20 mm or DN25 mm with Â¾ NPT or socket welded\n2) Field Piping from panel to main water system:\nAll: Schd. 80 PVC, C-PVC or PVDF socket glued\n\nCONTROL MODULE AND INTERLOCKS\n1) Electronic PLC or microprocessor controller\nThe electronic PLC or the microprocessor shall provide automatic control for all operating functions. NEMA 4. All the wiring factory-installed and tested. Comply with Section 26Â 05Â 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) and NFPA 70.\nPower requirements: 100-240 VAC Â± 10%, 50/60 Hz\n2) Alarm indicator and silence button.\nWarning Alarms: high/low values, no water flow through the panel, no water flow through the free and/or total chlorine housing\n3) Status Indicators\nThe Controller operating screen shall display the following functions during normal operation\nThree water quality parameters per page, operator can scroll pages up and down with the up/down arrows\nLow and high alarm for each parameter\nInterlock (if any) of each parameter\nDigital/analog output repetition (if any) of each parameter\n4) Interlocks\nThe controller shall be capable of interlocking any 4-20 mA input with a dry contact digital output to control and external device (drain valve, dosing pump) proportionally.\n5) Drain valve\nThe controller shall have the capability to operate an onboard drain valve with a timer. The timer shall allow operators to set a minimum of four daily drain events. External timers and drain systems will not be accepted.\n\nINPUTS\nFlow switch (up to three flow switches: water quality monitoring panel, free chlorine probe housing, total chlorine probe housing)\nDigital Inputs (1-15) Isolated dry contact dry contact, Namur.\nAnalog Inputs (1-10) 4-20 mA: 2-wires, configurable active (internally powered by 24 VDC) or passive (powered by externa device). Analog inputs shall be configured to accept external 4-20 mA reading\nORP Sensors (8) or pH sensors (8)\nConductivity (4) sensors\nTemperature (5) sensors\n\nOUTPUTS\nTwelve (12) dry contact switches\nThree analog outputs shall be, 4-20 mA: Isolated, 500-ohm maximum resistive load, internally powered\n\nSOFTWARE FEATURES\nThe water quality monitor software shall:\nSelf-tests shall be available to verify the integrity of the control module s sensor input circuitry.\nAn online reminder for electrode calibration shall be available.\nEach sensor input shall feature a two-point calibration.\nThe analog inputs shall be configurable for level sensors, corrosion monitors, or any other type of transmitter, providing appropriate units of measure and scaling.\nThe optional digital inputs shall be configurable for level switches, verification switches or generic interlock operation.\nStatus reports and data files shall be sent automatically via email on either a cyclical basis or for a specific date range. The date range can be adjusted by the operators and can be changed at any time.\nThe controller configuration may be entered by downloading them from one controller and uploading them into another controller via USB or remotely.\nAccess to the controller shall be possible using a USB connection, Ethernet, direct modem-to-modem, via the Internet, or via the local display and keypad, simultaneously if desired.\nNo proprietary software shall be required on the user s computer to communicate with the controller, or to view or change configuration.\nThe controller software shall be able to be upgraded remotely via the Internet.\nThe software must allow onsite data logging via USB with configurable time intervals.\n\nSENSORS / PROBES\nORP\nMaterials of construction: Glass, PVC\nProcess connections: PG 13.5 Â½\nTemperature range: +23F - +190 F, -5C to +90 C\nPressure range: 0-100 psi (inline) 0-215 PSI (flow discharge)\nMeasure range: -1,000 mV - + 1,000 mV\nAccuracy: Â± 1 mV\npH\nMaterials of construction: Glass, PVC\nProcess connections: PG 13.5 Â½\nTemperature range: +32F to +175F, -5C to +80 C\nPressure range: 0-100 psi (inline) 0-215 PSI (flow discharge)\nMeasure range: - 0 pH - +14 pH\nAccuracy: Â± 0.1 pH\nPre-dilution flow sensor\nMaterials of construction: stainless steel\nDigital readout: programmable digital readout to display water flow (gpm/cfu), temperature and water velocity (ft/s)\nAnalog outputs: minimum one 4-20 mA to retransmit any value\nDigital outputs: dry contact switch for min and max flow alarm\nTemperature range: -4 F 194 F\nPressure range: 0 1,450 psi\nAccuracy: Â± 0.1 gpm, Â± 0.1 F\nFree Chlorine (option add)\nMaterials of construction: PVC, PMMA (probe holder)\nProcess connections: probe holder inlet/outlet 3/8\nTemperature range: +32F to +120 F, 0C to +49 C\nPressure range: 0-14 psi\nMeasure range: 0 ppm - +10 ppm\nAccuracy: Â± 0.1 ppm\nTotal Chlorine (option add)\nMaterials of construction: PVC, PMMA (probe holder)\nProcess connections: probe holder inlet/outlet 3/8\nTemperature range: +32F to +120 F, 0C to +49 C\nPressure range: 0-14 psi\nMeasure range: 0 ppm - +10 ppm\nAccuracy: Â± 0.1 ppm\nPressure\nMaterials of construction: stainless steel\nProcess connections: Â½\nTemperature range: -4F to 257F -5C to +125 C\nPressure range: 0 - 280 psi (measure accuracy is guaranteed up to 140 PSI)\nMeasure range: 0 - 140 psi\nAccuracy: Â± 0.25% of maximum measure (0.35 PSI)\nConductivity\nMaterials of construction: stainless steel\nProcess connections: Â¾\nTemperature range: +32F to +266F 0C to +130 C\nPressure range: 0 - 217 psi\nMeasure range: 0 20,000 mS\nAccuracy: Â± 1 mS\nTemperature\nMaterials of construction: stainless steel\nProcess connections: Â½\nTemperature range: -58F to +500F -50C to +260C\nPressure range: 0 - 725 psi\nMeasure range: -58F to +500F -50C to +260C\nAccuracy: Â± 0.1F\n\nSENSORS / PROBES CALIBRATION\nA. The electrodeless conductivity sensor calibration shall be a two-point calibration (in air and at the process value), or a single point process calibration.\nB. The ORP electrode calibration shall be a two-point calibration utilizing standard ORP buffer solutions\nC. The pH electrode calibration shall be a two-point calibration utilizing standard pH buffer solutions\nD. The total and/or free chlorine electrode calibration shall be two-point calibrations with zero-point calibration utilizing clean, oxidizer-free water and second point process calibration utilizing a DPD test.\n\nCOMMUNICATION AND DATALOG\nCommunication\nThe water quality monitor shall include an embedded web server utilizing standard BACnet IP, Modbus TCP/IP and Modbus RTU communications.\nRemote communications can be established via the Internet or on a direct line with modem-to-modem capability.\nMultiple users can access the controller simultaneously.\nThe water quality monitor shall have the capability of communicating with other water quality monitors in a master/slave configuration\nModbus TCP/IP client connectivity shall be standard\nData log\nThe water quality monitor shall data log all water quality parameters. Data recording frequency can be changed to once per day to every second.\nWater quality reporting feature shall be cloud-based to provide out of limit alarms via email or text, in real-time, to alert site operators of abnormal or dangerous conditions immediately\nController data storage shall not expire. Data must be recorded 24/7 - 365 days per year with no storage limits.\nOut of limit alarms shall be generated in real-time\n1. Alarms and emails are generated in real-time as operator logs and service reports are recorded\n2. Alarms are in plain text message format to ensure compatibility with all devices\nThe reporting software shall have the following capabilities\nTrending wet test data against controller data\nStoring controller data with no storage limitations\nAutomatically emailing and text notifications reports\nProvide data visualizations for fast and easy identification of alarm conditions including green, yellow, and red colored alarms\nAll the controllers shall be accessible remotely from the same platform (one website) with a unique log in username and password. Single username and password for each individual controller shall not be accepted.\nAll the controllers shall be available from a main dashboard\nThe main dashboard shall show the main status of each controller (ON/OFF/ALARM)\nOperators can access each single controller from the main dashboard and then return to the main dashboard.\n\nSite\nExisting System Type\nQuantity\nLocation\n\nEast Orange Campus\nSanikill Generator Model #SKLP-800\n1\nBldg. 1\nLyons Campus\nSanikill Generator Model #SKLP-150\n5\nBldg. 7, 53, 57,\n135,143\nEast Orange Campus\nSaniware Single CWQM+MonoS\n2\n\n.\nBldg. 1/8-3 & Penthouse\nÂ·East Orange\nCampus\nSaniware Dual CWQM+MonoS\n3\nBldg. 1, 2, 15\nLyons Campus\nSaniware Dual CWQM+MonoS\n5\nBldg. 7, 53: 57,\n135,143\n\nJ\n\nMaintenance & Service Schedule\n\nServices\nMonthly\nQuarterly\nAnnually\nOn site Water Analysis & Reporting\nX\n\nReview of Operator Logs\nX\n\nClean & Calibrate Probes\nX\n,\n\nInventory Control & Order Entry\nX\n\nAdjust Chemical Application Levels\nX\n\nProbe & Pump Calibrations\n\nX\n\nComplete Wetted parts overhaul & test\n\nX\nOperator Training\n\nX\n\nAuthorized Service Kits and Parts\n\nSystem\nParts # / Description\nQuantity\nFrequency\nSanikill SKLP 800\nKSKLP 800 Maintenance kit\n1\nAnnual\nSanikill SKLP 150\nKSKLP 150 Maintenance kit\n5\nAnnual\nSaniware CWQM\nCS676HTTC SS Probe (hot)\n9\n\n-\nAs needed\nSaniware CWQM\n190984-05 Cond/temp Probes (cold)\n8\nAs needed\nSaniware CWQM\nS800 CR pH Probe\n16\nAs needed\nSaniware CWQM\nPX-209-300G5 Pressure Transmitter\n16\nAs needed\nSaniware CWQM\nWTCB-20 19199 Total chlorine probe\n8\nAs needed\nSaniware CWQM\nWELMVR-22 ORP Probe\n8\nAs needed\n\nPerformance Period: [firm-F1xed-Pnce] (CO). Work hours are between 7:00am and 4:30 pm on normal weekdays. Work on Federal Holidays is excluded from this contract.\n5. Type of Contract: Firm-Fixed-Price.\nÂ·s. GENERAL REQUIREMENTS\n- Upon Completion ensure that all debris is cleaned up and removed from VA premises by contractor.\n\nC. SPECIFIC MANDATORY TASKS AND ASSOCIATED DELIVERABLES,\n\nContractor will follow all VA, OSHA, and EPA safety policies. The contractor shall supply all certifications and specifications of compliance with contract requirements as part of their response to solicitation.\n\nAll repairs will be inspected by a VA contracting Officers Representative.\nD. CHANGES TO STATEMENT OF WORK\n\nAny changes to this SOW shall be authorized and approved only through written correspondence from the CO.","html":"J046   Maintenance Repair, and Rebuilding of Equipment   Water Purification and Sewage Treatment Equipment\nSOL:Â  36C24225Q0492\nDUE:  May 20, 2025, at 10:00 AM EST.Â Â Â Â Â Â Â Â  \nSET ASIDE: N/AÂ Â Â Â Â Â Â Â Â Â Â Â Â  \nNAICS: 325998   All Other Miscellaneous Chemical Product and Preparation Manufacturing. \nPOP:  12-month Base Year with 4 option years. \nAGENCY:Â  New Jersey VA Healthcare System\nPOC:Â Natalie Acevedo, email Natalie.Acevedo@va.gov Â Â  Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â  \nDESCRIPTION: NOTICE OF INTENT TO AWARD A SOLE SOURCE CONTRACT TO Klenzoid, Inc.Â  \nMarket research was conducted and determined that Klenzoid, Inc.is the only vendor capable of meeting the requirement at New Jersey VAHCS. \nThis Notice of Intent is not a request for Proposals or Quotations.Â  No solicitation document exists, and no telephone or email inquiries will be accepted.Â  Â Â Â Â Â Â Â  \nNo contract award will be made based on proposals, or quotations received in response to this notice.Â  Â Â Â Â Â Â Â  \nThe government MAY consider all Expressions of Interest (EOI) received prior to May 20,2025. Â  \nA determination by the Government not to compete this proposed contract based upon responses to this notice is solely within the discretion of the Government.Â  \nInformation received will be considered solely for the purpose of determining whether to conduct a competitive procurement.Â  Â  \nResponses to this notice must be emailed to Natalie.Acevedo@va.gov and received by 10:00 AM EST on May 20, 2025.Â Â  Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â  \nSubmitters are responsible for ensuring their EOI reaches the designated contracting officer on-time.Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â  \nSee attached Statement of Work below for additional details.Â Â Â Â Â  \nIf you have any questions or concerns, please contact me.\n\n\n\n\n\n\nSTATEMENT OF WORK\n\n\nA. GENERAL INFORMATION\n\nTitle of Project: Supplemental Disinfection and Continuous Water Quality Monitoring\nBackground: Per VA Directive 1061- Prevention of Healthcare Associated Legionnaires Disease and Scald Injury from Potable Water Distribution Systems, the VANJHCS Lyons & East Orange, NJ campus VA Medical Centers requires Supplemental Disinfection and Continuous Water Quality Monitoring. VANJHCS wishes to continue to lease Monochloramine Supplemental Disinfection systems and provide for the continued operation, maintenance and remote monitoring of both the Monochloramine systems and the Continuous Water Quality Monitoring and Monochloramine Stabilizer Systems. The combined requirement in accordance with the statement of work (SOW) is to provide for the continued operation and upgrading of the existing Monochloramine Generators for supplemental disinfection including the supply and maintenance of the equipment, supply and delivery of National Sanitation FoundationÂ® certified chemical reagents, parts, and labor necessary for upgrading and the continued operation and maintenance, probe calibration and replacement (as required) of the Continuous Water Quality Monitoring(CWQM) panels in the domestic cold and hot water System in compliance with the current VA 1061 Directive . \nScope of Work: The contractor shall provide all Labor and Material necessary to provide and install the specified equipment and accomplish the continued maintenance and calibration services as described in the statement of work (SOW).\nEast Orange Campus\nThe current Saniware Continuous Water Quality Monitoring panels (CWQM) and Sanikill Monochloramine Generator in East Orange have been subject to numerous over temperature environmental conditions over several years and are nearing the end of their life cycle.  To ensure compatibility and up to date technology the government wishes to upgrade these systems in the first year of the contract from the same manufacture to the most current configuration and materials of construction. (See basis of Design following)\nThe Contractor shall remove and replace the existing Sanipur Monochloramine generator with a new Sanikill Tec Model SKTEC - LT2010 along with all five (5) Saniware CWQM panels as per the schedule in the SOW.  Monthly Testing, Calibration, Reporting and Preventative Maintenance services of the Monochloramine generators and Saniware CWQM panels, including supply and delivery of chemical reagents, probes, parts, labor and associated services are part of the performance requirements throughout the period of the contract. \n\nLyons Campus\nThe current CWQM panels and Monochloramine Generators units at Lyons Campus have not been subject to overtemperature environmental conditions and are operating reliably currently. The contractor will be required to continue to operate and maintain these units. To ensure compatibility, the government wishes to upgrade these systems over five years of the contract term by removing and replacing the monochloramine Generators and the CWQM panels to the most current configuration and materials of construction. (See the Basis of Design following). The contractor will upgrade one Building with existing Monochloramine Generators and CWQM panels each year over the term of the contract.\n\nThere are currently Five (5) Sanipur Monochloramine Generators for supplemental water treatment, serving all the domestic water entering the buildings and five (5) Dual (hot & cold water) CWQM on the Lyons campus, one each in buildings 7, 53, 57, 135 and 143. \n\n\nBASIS OF DESIGN\nMonochloramine Generator - 1,000 grams/hour\n\nSYSTEM DESCRIPTION\nThe monochloramine system shall be a complete packaged unit to include both the monochloramine generator and the reagent dosing tanks. The water shall be fed to the reactor chamber by a recirculation pump supplied with the system. Reagent chemical addition shall be by electromagnetic membrane pumps which are synchronized to reach the optimum mixing rate in the reactor chamber. The dosing pumps shall feed the precursors subsequently with a delay (Delta T) that is automatically calculated by the electronic controller. The monochloramine shall be produced and exit the reactor within the water flow, which is then introduced in the water in direct proportion to flow and Oxidation Reduction Potential (ORP). An ORP probe placed on a recirculation sampling loop shall act to control the level of monochloramine by adjusting the dosage to maintain it in the specified range. The whole monochloramine generator assembly shall be an NSF/ANSI Standard 61 certified drinking water component. NSF/ANSI Standard 61 certification of individual components in contact with drinking water will not be accepted.  \n\nPERFORMANCE REQUIREMENTS\nElectronic Control Unit\nThe system shall be controlled by a single electronic PLC or microprocessor control unit. The controller will have a single screen to display all aspects of the operation of the system. A single keypad shall provide access to the control parameters.\n\n2) Connection to Building Automation Systems.\n BAS Connection   provide interface for the Building Automation System to monitor operation, set points, status indicators, and alarms via ModBus/TCP, Modbus RTU and BACnet. Connection to BAS is by the facility or their BAS contractor.\n\n      Dosing Pump Flow/Level Sensors\nThe system shall be equipped with flow sensors in each reagent dosing pump discharge to avoid improper mixing of the reagents. A flow fault switch will alarm the system to low or lack of water flow to the pre-dilution flow assembly and disable the system and send an alarm notification via the Building Automation System.\nThe unit shall be equipped with four level sensors for reagent tanks (two minimum level switches + two empty level switches).\n      Predilution flow sensors\nThe system shall have a stainless-steel pre-dilution flow meter to input to the microprocessor to maintain proper synchronization of the reagent pumps and insure accurate mixing of reagents. The pre-dilution flow meter shall be capable of measuring the flowrate in gpm and cfm, water velocity in ft/s and water temperature. The pre-dilution water meter shall be capable of outputting a programmable 4-20 mA analog output proportional to the water flow. The pre-dilution water meter shall also be capable of outputting a dry contact switch for high and low flow alarm.\n      3) Reagent Chemicals\nThe reagents chemicals shall be NSF/ANSI Standard 60 certified drinking water additives and so certified by The National Sanitation Foundation (NSF). Products certified by other third-party certifications agencies are not acceptable. The Chlorine source reagent chemical shall be a minimum 10% solution manufactured from a high purity, electrochemically produced and pH stabilized sodium hypochlorite. Total metals shall be less than 1% and pH shall be properly adjusted to maintain maximum stability after delivery. The Ammonia source reagent chemical shall be a maximum 19% ammonium chloride manufactured from food grade ammonium chloride to ensure stability and safe handling or a maximum 40% ammonium sulfate. Reagent chemicals shall be manufactured locally under license by the monochloramine equipment manufacturer to ensure compatibility and proper selection for the system. Chemical shall be supplied, delivered and applied only by manufactures authorized distributor.\n4) Reagent dosing pumps\nReagent dosing pumps shall be precision metering pumps capable of   accuracy + or   0.1 ml/min. Pump shall feature a stroke length only adjustment to avoid the possibility of frequency or input changes. Liquid end assemblies shall have acrylic heads with all Teflon diaphragms. Check valve assemblies are to be Teflon with Viton or Teflon O-rings and ceramic check balls. \n\n\n\n5) Corrosion Inhibitor Feed Option\nThe monochloramine generator unit shall be capable of automatically dosing a corrosion inhibitor based on system water flow and control shall be accomplished by the same unit as the monochloramine addition. Separate corrosion feed control sources shall not be acceptable.\n MANUAL VALVES\n1) Monochloramine unit reactor or predilution flow assembly\nPVDF, true union ball valves, Viton or Teflon O-ring, welded or threaded.2) Sample Valve, Product Water Sample Valve\nPVDF needle valves with Viton seats and seals.\nPIPING\n 1) Unit Predilution flow Assembly\nSchd. 80 PVDF, DN20 mm or DN25 mm with socket welded connections.\n            2) Field Piping from unit to point of injection:\n      All: Schd. 80 PVC, C-PVC or PVDF socket glued or welded\n\n\nCONTROLS\n1) Electronic PLC or microprocessor controller\nThe electronic PLC or the microprocessor shall provide automatic control for all operating functions. NEMA 4. All the wiring factory-installed and tested. Comply with Section 26Â 05Â 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) and NFPA 70.\n2) Alarm indicator and silence button.\nWarning Alarms: improper reagent feed, minimum reagent level, analysis flow fault. \nAutomatic Shutdown and Alarm: regent flow fault, empty reagent tank, loss of predilution flow, reading Error (loss of input signal).\n3) Status Indicators\nThe Controller operating screen shall display the following functions during normal operation\nRegent pump flow validation \nORP and Free/Total chlorine reading\nOperating Mode\nDelta time differential of reagents pumps stroke\nWater flow rate\nMonochloramine production rate in grams/hr.\nMonochloramine set point\nWater or enclosure ambient temperature\n\nINSTRUMENTATIONS AND DISPLAY\nAll instrumentation readouts panel-mounted in FRP enclosures rated NEMA All factory wiring. Comply with NFPA 70.\nFlow indicators for water reactor flow rate.\nFlow indicators for reagent lines.\nOne (1) ORP indicator measuring water quality with digital displays, alarm relays and automatic temperature compensation.\nTwo (2) chlorine residual sensors (free and/or total).\nOne (1) water meter input signal.\nOne (1) pre-dilution water meter signal.\nTwo (2) analog reagent tank levels inputs.\nOne (1) pH sensor.\nThree (3) analog 4-20 mA outputs\nTwelve (12) digital dry contact outputs\nTotal of fifteen (15) digital dry contact inputs\nModbus RTU.\nModbus/TCP interface for the Building Automation System to read and record information\nAbility to convert Modbus/TCP to BACnet/IP\n\n\n\nBASIS OF DESIGN\nContinuous Water Quality Monitoring Panels (CWQM) \n\nSYSTEM DESCRIPTION\nThe multi I/O continuous water quality monitor panels shall be capable of measuring system conductivity, pH, temperature, pressure, turbidity and oxidant levels (ORP/free chlorine/total chlorine). The conductivity sensors shall be an electrodeless style. All sensors shall have integral signal conditioning. Additional inputs shall include a flow switch, fifteen digital inputs, ten 4-20 mA inputs, eight inputs for pH and/or ORP probes, four inputs for conductivity sensors and five inputs for temperature probes.  Outputs shall include twelve digital dry contact switches and three 4-20 mA outputs. Digital communications shall be via USB, Ethernet, Modbus RTU and/or optional modem. All the controllers shall be networked together over Ethernet and shall be monitored from the same online page. Integration with DCS, SCADA system or building energy management systems shall be possible using the optional Modbus TCP/IP or Modbus RTU or BACnet IP feature. The controller shall be accessible via the Internet for configuring, data logging, and controlling digital outputs. The controller shall provide notification of alarm conditions via dry contact closure, text message and/or email. All water quality parameters shall be data logged in real time (24/7) and the data logs provided to the user as raw and visualized data.  The data must be stored online with no time limitations. The water quality monitor system shall be capable of accommodating one or two manifolds (pre-dilution loop/s) on the same panel. Each manifold shall be equipped with inline pH, ORP, Conductivity, Temperature, Turbidity and Pressure sensors. Cold water shall have total chlorine probes. All the probes from either the single or double manifold must be pre-wired to the same electronic controller. The whole water quality monitor system shall be NSF/ANSI Standard 61 certified drinking water components. NSF/ANSI Standard 61 of the single components in contact with drinking water will not be accepted.\n\nELECTRONIC CONTROLLER\n1) Electronic Control Unit\nThe system shall be controlled by a single electronic PLC or microprocessor control unit. Backlit LCD Graphics Module display shall indicate the process values, and the status of outputs and alarms. The controller will have a single screen to display all aspects of the operation of the system. A keypad shall provide access to the control parameters.\nBAS Connection   provide ModBus/TCP/RTU or BACnet interface for the Building Automation System to monitor operation, set points, status indicators, and alarms.\nThree levels of access codes shall be available to protect all set points and calibrations, while allowing the user to view any set point.\nMANUAL VALVES AND MATERIALS\n1) Water quality monitoring panel or predilution flow assembly\n PVDF, true union ball valves, Viton or Teflon O-ring, socket welded.\n2) Sample Valve, Product Water Sample Valve\n PVDF needle valves with Viton seats and seals.\n\nPIPING\n1) Water quality monitoring panel\nPVDF, DN20 mm or DN25 mm with Â¾  NPT or socket welded \n2) Field Piping from panel to main water system:\nAll: Schd. 80 PVC, C-PVC or PVDF socket glued\n\nCONTROL MODULE AND INTERLOCKS\n1) Electronic PLC or microprocessor controller\nThe electronic PLC or the microprocessor shall provide automatic control for all operating functions. NEMA 4. All the wiring factory-installed and tested. Comply with Section 26Â 05Â 21, LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW) and NFPA 70.\nPower requirements: 100-240 VAC Â± 10%, 50/60 Hz\n2) Alarm indicator and silence button.\nWarning Alarms: high/low values, no water flow through the panel, no water flow through the free and/or total chlorine housing\n3) Status Indicators\nThe Controller operating screen shall display the following functions during normal operation\nThree water quality parameters per page, operator can scroll pages up and down with the up/down arrows\nLow and high alarm for each parameter\nInterlock (if any) of each parameter\nDigital/analog output repetition (if any) of each parameter\n4) Interlocks\nThe controller shall be capable of interlocking any 4-20 mA input with a dry contact digital output to control and external device (drain valve, dosing pump) proportionally.\n5) Drain valve\nThe controller shall have the capability to operate an onboard drain valve with a timer. The timer shall allow operators to set a minimum of four daily drain events. External timers and drain systems will not be accepted.\n\nINPUTS\nFlow switch (up to three flow switches: water quality monitoring panel, free chlorine probe housing, total chlorine probe housing)\nDigital Inputs (1-15) Isolated dry contact dry contact, Namur.\nAnalog Inputs (1-10) 4-20 mA: 2-wires, configurable active (internally powered by 24 VDC) or passive (powered by externa device). Analog inputs shall be configured to accept external 4-20 mA reading\nORP Sensors (8) or pH sensors (8)\nConductivity (4) sensors\nTemperature (5) sensors\n\nOUTPUTS\nTwelve (12) dry contact switches\nThree analog outputs shall be, 4-20 mA: Isolated, 500-ohm maximum resistive load, internally powered\n\nSOFTWARE FEATURES\nThe water quality monitor software shall:\nSelf-tests shall be available to verify the integrity of the control module s sensor input circuitry.\nAn online reminder for electrode calibration shall be available.\nEach sensor input shall feature a two-point calibration.\nThe analog inputs shall be configurable for level sensors, corrosion monitors, or any other type of transmitter, providing appropriate units of measure and scaling.\nThe optional digital inputs shall be configurable for level switches, verification switches or generic interlock operation.\nStatus reports and data files shall be sent automatically via email on either a cyclical basis or for a specific date range. The date range can be adjusted by the operators and can be changed at any time.\nThe controller configuration may be entered by downloading them from one controller and uploading them into another controller via USB or remotely.\nAccess to the controller shall be possible using a USB connection, Ethernet, direct modem-to-modem, via the Internet, or via the local display and keypad, simultaneously if desired.\nNo proprietary software shall be required on the user s computer to communicate with the controller, or to view or change configuration.\nThe controller software shall be able to be upgraded remotely via the Internet.\nThe software must allow onsite data logging via USB with configurable time intervals.\n\nSENSORS / PROBES\nORP\nMaterials of construction: Glass, PVC\nProcess connections: PG 13.5  Â½ \nTemperature range: +23F - +190 F, -5C to +90 C\nPressure range: 0-100 psi (inline) 0-215 PSI (flow discharge)\nMeasure range: -1,000 mV - + 1,000 mV\nAccuracy: Â± 1 mV\npH\nMaterials of construction: Glass, PVC\nProcess connections: PG 13.5  Â½ \nTemperature range: +32F to +175F, -5C to +80 C\nPressure range: 0-100 psi (inline) 0-215 PSI (flow discharge)\nMeasure range: - 0 pH -  +14 pH\nAccuracy: Â± 0.1 pH\nPre-dilution flow sensor\nMaterials of construction: stainless steel\nDigital readout: programmable digital readout to display water flow (gpm/cfu), temperature and water velocity (ft/s)\nAnalog outputs: minimum one 4-20 mA to retransmit any value\nDigital outputs: dry contact switch for min and max flow alarm\nTemperature range: -4 F   194 F\nPressure range: 0   1,450 psi\nAccuracy: Â± 0.1 gpm, Â± 0.1 F\nFree Chlorine (option add)\nMaterials of construction: PVC, PMMA (probe holder)\nProcess connections: probe holder inlet/outlet 3/8 \nTemperature range: +32F to +120 F, 0C to +49 C\nPressure range: 0-14 psi\nMeasure range: 0 ppm -  +10 ppm\nAccuracy: Â± 0.1 ppm\nTotal Chlorine (option add)\nMaterials of construction: PVC, PMMA (probe holder)\nProcess connections: probe holder inlet/outlet 3/8 \nTemperature range: +32F to +120 F, 0C to +49 C\nPressure range: 0-14 psi\nMeasure range: 0 ppm -  +10 ppm\nAccuracy: Â± 0.1 ppm\nPressure\nMaterials of construction: stainless steel\nProcess connections: Â½ \nTemperature range: -4F to 257F -5C to +125 C\nPressure range: 0 - 280 psi (measure accuracy is guaranteed up to 140 PSI)\nMeasure range: 0 - 140 psi\nAccuracy: Â± 0.25% of maximum measure (0.35 PSI)\nConductivity\nMaterials of construction: stainless steel\nProcess connections: Â¾ \nTemperature range: +32F to +266F 0C to +130 C\nPressure range: 0 - 217 psi\nMeasure range: 0   20,000 mS\nAccuracy: Â± 1 mS\nTemperature\nMaterials of construction: stainless steel\nProcess connections: Â½ \nTemperature range: -58F to +500F -50C to +260C\nPressure range: 0 - 725 psi\nMeasure range: -58F to +500F -50C to +260C\nAccuracy: Â± 0.1F\n\nSENSORS / PROBES CALIBRATION\nA. The electrodeless conductivity sensor calibration shall be a two-point calibration (in air and at the process value), or a single point process calibration.\nB.   The ORP electrode calibration shall be a two-point calibration utilizing standard ORP buffer solutions\nC. The pH electrode calibration shall be a two-point calibration utilizing standard pH buffer solutions\nD. The total and/or free chlorine electrode calibration shall be two-point calibrations with zero-point calibration utilizing clean, oxidizer-free water and second point process calibration utilizing a DPD test.\n\n\n\nCOMMUNICATION AND DATALOG\nCommunication\nThe water quality monitor shall include an embedded web server utilizing standard BACnet IP, Modbus TCP/IP and Modbus RTU communications. \nRemote communications can be established via the Internet or on a direct line with modem-to-modem capability. \nMultiple users can access the controller simultaneously.\nThe water quality monitor shall have the capability of communicating with other water quality monitors in a master/slave configuration\nModbus TCP/IP client connectivity shall be standard\nData log\nThe water quality monitor shall data log all water quality parameters. Data recording frequency can be changed to once per day to every second. \nWater quality reporting feature shall be cloud-based to provide out of limit alarms via email or text, in real-time, to alert site operators of abnormal or dangerous conditions immediately  \nController data storage shall not expire. Data must be recorded 24/7 - 365 days per year with no storage limits.\nOut of limit alarms shall be generated in real-time\n1. Alarms and emails are generated in real-time as operator logs and service reports are recorded\n2. Alarms are in plain text message format to ensure compatibility with all devices\nThe reporting software shall have the following capabilities\nTrending wet test data against controller data\nStoring controller data with no storage limitations\nAutomatically emailing and text notifications reports\nProvide data visualizations for fast and easy identification of alarm conditions including green, yellow, and red colored alarms\nAll the controllers shall be accessible remotely from the same platform (one website) with a unique log in username and password. Single username and password for each individual controller shall not be accepted.\nAll the controllers shall be available from a main dashboard\nThe main dashboard shall show the main status of each controller (ON/OFF/ALARM)\nOperators can access each single controller from the main dashboard and then return to the main dashboard.\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\nSite\n Existing System Type\nQuantity\nLocation\n\n\n\n\nEast Orange Campus\nSanikill Generator Model #SKLP-800\n 1\nBldg. 1\nLyons Campus\nSanikill Generator Model #SKLP-150\n5\nBldg. 7, 53, 57,\n135,143\nEast Orange Campus\nSaniware Single CWQM+MonoS\n2\n\n.\nBldg. 1/8-3 & Penthouse\nÂ·East Orange\nCampus\nSaniware Dual CWQM+MonoS\n3\nBldg. 1, 2, 15\nLyons Campus \nSaniware Dual CWQM+MonoS\n5\nBldg. 7, 53: 57,\n135,143\n\nJ\n\n\n\n\n\nMaintenance & Service Schedule\n\nServices  \nMonthly\nQuarterly\nAnnually\nOn site Water Analysis & Reporting\nX\n\n\nReview of Operator Logs\nX\n\n\nClean & Calibrate Probes\nX\n,\n\n\nInventory Control & Order Entry\nX\n\n\nAdjust Chemical Application Levels\nX\n\n\nProbe & Pump Calibrations\n\nX\n\nComplete Wetted parts overhaul & test\n\n\nX\nOperator Training\n\n\nX\n\nAuthorized Service Kits and Parts\n\nSystem\nParts # / Description\nQuantity\nFrequency\nSanikill SKLP 800\nKSKLP 800 Maintenance kit\n1\nAnnual\nSanikill SKLP 150\nKSKLP 150 Maintenance kit\n5\nAnnual\nSaniware CWQM\nCS676HTTC SS  Probe (hot)\n9\n\n-\nAs needed\nSaniware CWQM\n190984-05 Cond/temp Probes (cold)\n8\nAs needed\nSaniware CWQM\nS800 CR pH Probe\n16\nAs needed\nSaniware CWQM\nPX-209-300G5 Pressure Transmitter\n16\nAs needed\nSaniware CWQM\nWTCB-20 19199 Total chlorine probe\n8\nAs needed\nSaniware CWQM\nWELMVR-22 ORP Probe\n8\nAs needed\n\n\nPerformance Period: [firm-F1xed-Pnce] (CO). Work hours are between 7:00am and 4:30 pm on normal weekdays. Work on Federal Holidays is excluded from this contract.\n5. Type of Contract: Firm-Fixed-Price.\nÂ·s. GENERAL REQUIREMENTS\n- Upon Completion ensure that all debris is cleaned up and removed from VA premises by contractor.\n\nC. SPECIFIC MANDATORY TASKS AND ASSOCIATED DELIVERABLES,\n\nContractor will follow all VA, OSHA, and EPA safety policies. The contractor shall supply all certifications and specifications of compliance with contract requirements as part of their response to solicitation. \n\nAll repairs will be inspected by a VA contracting Officers Representative.\nD. CHANGES TO STATEMENT OF WORK\n\nAny changes to this SOW shall be authorized and approved only through written correspondence from the CO.","origin":"detail"},"contacts":[{"name":"Natalie Acevedo","role":"primary","email":"natalie.acevedo@va.gov","phone":"718 584 9000 x4356","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["325998"],"award":{"awardee":{}},"attachments":[{"resource_id":"668e8e8414ed44f4827ae25a36702e9f","name":"36C24225Q0492_1.docx","kind":"file","mime_type":".docx","size_bytes":46822,"posted_at":"2025-05-15T15:03:00.528Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/668e8e8414ed44f4827ae25a36702e9f/download","mirrored":false}],"awards":[],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"SPE4A627T135D","latest_notice_id":"0d4cd29ce3f946febe5196cb72faf4da","title":"68--SCALE PREVENTION CO","solicitation_number":"SPE4A627T135D","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":null,"due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE4A6","office_name":"DLA AVIATION","naics":"325998","psc":"68","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"N CO: LINE 0001 QTY 227 UI BX DELIVER TO: W1A8 DLA DISTRIBUTION BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"27SIMACQCD610006","latest_notice_id":"d7d61410b5c74abaa12e9ac0fd0a459e","title":"RFI to conduct market research to identify potential vendors with products available that meet the capability criteria listed","solicitation_number":"27-SIMACQ-CD-61-0006","notice_type":"r","first_type":"r","first_posted":"2026-11-02","last_posted":"2026-11-24","notices":3,"due_at":"2026-12-01T17:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00167","office_name":"NSWC CARDEROCK","naics":"325998","psc":"8030","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8030)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"124PSA27Q0030","latest_notice_id":"b02df73747c741139843946eb79bdc24","title":"Extended Range Rockets","solicitation_number":"124PSA27Q0030","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-03T22:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-1205","sub_name":"USDA, DEPARTMENTAL ADMINISTRATION","office_key":"o-124PSA","office_name":"OCP SERVICE AND SUPPLY DIV","naics":"325998","psc":"1370","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 1370)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":5,"indexable":false}