{"canonical":"https://sealedbidder.com/opportunities/36c24225q0344","key":"36C24225Q0344","url":"https://sealedbidder.com/opportunities/36c24225q0344","title":"J061--Services FY24 1x - BK & SA Load Bank Testing","solicitation_number":"36C24225Q0344","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-18T17:00:00Z","first_posted":"2025-02-12","last_posted":"2025-02-12","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"811310","psc":"J061","set_aside":null,"place_state":"NY","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"36047","place_county_name":"Kings County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"b88b76fb93cd4b1585d58adbb77800ba","title":"J061--Services FY24 1x - BK & SA Load Bank Testing","solicitation_number":"36C24225Q0344","notice_type":"r","base_type":"r","posted":"2025-02-12","posted_at":"2025-02-12T18:38:47.826Z","due_at":"2025-02-18T17:00:00Z","due_date":"2025-02-18","cancelled":false,"archived":true,"archive_date":"2025-03-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b88b76fb93cd4b1585d58adbb77800ba/view","enriched":true,"history":[{"index":3,"title":"J061--Services FY24 1x - BK & SA Load Bank Testing","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-12T18:38:47.826Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b88b76fb93cd4b1585d58adbb77800ba","solicitation_number":"36C24225Q0344"}]}],"latest_notice_id":"b88b76fb93cd4b1585d58adbb77800ba","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-02-12","posted_at":"2025-02-12T18:38:47.826Z","created_at":"2025-02-12T18:38:45.606Z","modified_at":"2025-03-21T03:55:44.754Z","response_deadline":{"raw":"2025-02-18T12:00:00-05:00","utc":"2025-02-18T17:00:00Z","date":"2025-02-18","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b88b76fb93cd4b1585d58adbb77800ba/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J061--Services FY24 1x - BK & SA Load Bank Testing","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-20","archive_type":"auto_custom"},"history":[{"index":3,"title":"J061--Services FY24 1x - BK & SA Load Bank Testing","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-12T18:38:47.826Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"b88b76fb93cd4b1585d58adbb77800ba","solicitation_number":"36C24225Q0344"}],"contacts":[{"name":"Charles Collins","role":"primary","email":"Charles.Collins@va.gov","phone":"518-626-7200","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"b88b76fb93cd4b1585d58adbb77800ba","lineage_id":"b88b76fb93cd4b1585d58adbb77800ba","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-22T12:17:44.468554417Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"5cd511ed69f9ccf1e7b2dc143283bb4d5a6a99720086f061e42c2a06866ddd51","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-22T12:17:44.468554417Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought Notice\n\nThis is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law. \n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Albany, NY for the purpose of collecting information about Brooklyn & Saint Albans Annual Generator Load Bank Testing at The New York Harbor Healthcare System - Brooklyn Campus 800 Poly Place Brooklyn, NY 11209 and New York Harbor Healthcare System   St. Albans CLC 179-00 Linden Blvd. Jamaica, NY 11425. The VA is seeking to provide for this requirement as one time service.  The NAICS code identified for this requirement is 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance.  The requirement is detailed in the draft Statement of Work section of this document. \n\n(e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service or providing for these items, are encouraged to email a capability statement and full information to Anthony Murray at Anthony.Murray2@va.gov and Charles Collins at Charles.Collins@va.gov. \n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, DUNS number and address, point of contact and social-economic. Interested Parties must also provide documentation such as certification and training for staff that  demonstrates that they are an authorized solution distributor and/or authorized service technicians. Respondents who fail to provide the information request in the paragraph may be deemed non-responsive and incapable of meeting the government need. \n If contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy. \n\nThe following information is required for determining procurement strategy and viability of sources:\nSet aside requirements have limitations on subcontracting and must be adherent to the Limitation on Subcontracting  under FAR 19 and the Buy American Act (BAA) for commercial product procurements. This procurement is located in Brooklyn, New York and Jamaica, NY. Provide your supporting documentation to support your capability on adherence to Limitations on Subcontracting IAW FAR 19.505(b)(1) and VAAR 819.70 as prescribed in VAAR 852.219-75. \nIf your intention is to subcontract work, what tasks will be performed by you as the prime contractor? \nWhat tasks will require a subcontractor due to your inability to perform them within your company?  \n- Contractors shall also identify any Federal Supply Schedules that may carry the desired equipment or supplies. \n- Contractors shall identify pertinent point of contact for company, contractor DUNS number for size standard and socioeconomic verification in SAM and VIP, as well as for any intended subcontractors. \n - Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include letters from Original Equipment Manufacturers (OEM) if your firm is an authorized distributor. \n - Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. \n- Contractors shall include any relevant comments about the Attachment(s) if applicable. \n\n\n\n\n\nStatement of Work \n\nTITLE: Generator Annual Testing and Corrective Repair Service \n \nBACKGROUND: The Department of Veterans Affairs, New York Harbor Healthcare System Engineering Service seeks to acquire testing and annual service for fifteen (15) generators listed herein. All work will be performed in compliance with Joint Commission (JTC) and National Fire Protection Association (NFPA) 110 requirements.   The Brooklyn campus and St. Albans CLC generators are designed to provide back-up electrical power during an unforeseen outage of the primary electrical source and minimize additional disruptions to critical services. \n\nSCOPE: The Contractor shall provide qualified maintenance labor, equipment, tools, materials, parts, supplies, transportation, supervision, any other items, and non-personal services deemed necessary to perform load bank testing services on the following fifteen generators and provide any corrective maintenance repairs on any issues identified: \nST ALBANS CLC \n\n\n\n\nEquipment \nLocation \nMake \nModel \nSerial No. \nPM \nFrequency \nEmergency \nDiesel \nGenerators \nBldg. 64 Boiler Plant Upper Level \nCaterpillar 300KW \nC9 \nCAT000C9E NGP00992 \nAnnual \nBldg. 64 Boiler Plant Lower Level \nCaterpillar 1000KW \nC32 \nJSJ03348 \nAnnual \nBldg. 174 (serves \nBldg. 173 - Laundry) \nCaterpillar 750KW \nC27 \n2A300225 \nAnnual \nBldg. 167 (serves Bldgs. 85-87) \nCaterpillar 150KW \nD150-10 \nCAT00C71LL 7C00429 \nAnnual \nBldg. 88 (serves Commissary) \nCaterpillar 500KW \nC15 \nCAT00C15K NAP0599 \nAnnual \n\nBldg. 88 (serves \nDomiciliary area) \nCaterpillar 200KW \nD200-2 \nCAT00C71CE\nTG00540 \nAnnual \nBldg. 89 Basement \nCaterpillar 150KW \nD150-10 \nCAT00C71V\nL7C00430 \nAnnual \nBldg. 168 (serves Bldgs. 91-93) \nCaterpillar 150KW \nD150-10 \nCAT00C71A\nL7C00428 \nAnnual \nEmergency \nGas \nGenerators \nGuard Shack (Police) \nCaterpillar 150KW \nDG 30-2 \nCAT00G30A NB W00138 \nAnnual \nPump Station \nCaterpillar 300KW \nG300LG 6 \nGXJ04856-\nOLY00000 \nAnnual \n \n\nBROOKLYN CAMPUS \n\n\n\n\nEquipment \nLocation \nMake/Rating \nModel \nSerial No. \nPM \nFrequency \nEmergency \nDiesel \nGenerators \nMain Generator \nMain Generator \nCaterpillar 2025KW \n3516B \nYAT00416 \nAnnual \nBldg. 4 (Engineering) \nA-Board Generator \nCaterpillar 2200KW \n3516B \n1HN00551 \nAnnual \nOutpatient Clinic Generator \nOPC Generator Caterpillar \n600KW \n3508 \n23Z06777 \nAnnual \nBuilding 14 (Data Center) \nBldg. 14 Data Center \nGenerator Caterpillar \n400KW \n3456 \nCER00472 \nAnnual \nBuilding 13 \nBldg. 13 Critical Care \nGenerator MTU Onsite \nEnergy 250KW \n6R1600 \nDS250 \n16301004459 \nAnnual \n \nTASKS: \nThe Contractor must provide all labor and equipment to accomplish the task of annual load bank testing of fifteen generators and provide comprehensive reports upon completion.  \n \nThe Contractor must meet the Joint Commission s requirements for load banking testing as follows: \n30% of nameplate rating for 2 hours, followed by \n50% of nameplate rating for 1 hour, followed by \n75% of nameplate ratings for 1 hour, plus warm up and cool down time for a total continuous run of 4 hours.  \n \nThe Contractor must keep a written record of each generator run. The Contractor report include the following readings:  \nAt 15-minute intervals, \nLube Oil Pressure \nWater Temperature \nExhaust Temperature \nAmperes \nVolts \nFrequency \n \nThe report must contain certification statements that each generator was load bank tested in accordance with original equipment manufacturer s requirements. \n\nContractor must provide a report of any corrective maintenance or repair services that will be needed to complete the load bank testing, should any arise. The Contracting Officer will review the report with the facility Point of Contact (POC) and make a determination as to a strategy to accomplish corrective repair and maintenance. Should the Contracting Officer determine that the best value to the government comes from allowing the Contractor to perform corrective maintenance and repair, then a price quote will be requested and the changes in work will be effected via a written modification from the Contracting Officer. No other person has the agency to authorize such a change. \n\nIf these circumstances result in a need to extend the contract the agreed upon extension period will be included in a modification. \n\nGENERAL REQUIREMENTS: \nA post-award site visit must be conducted by the contractor to determine parking, pathways, and proper connections to the generator units.  \n\nThe Contractor must contact the maintenance supervisor of each site to schedule the load bank test and annual service. Supervisors contact information can be found under VA Engineering Service Point of Contact section herewith. \n \nPrior to starting the generators, the Contractor must perform a pre-run inspection to include checking the oil level, coolant level and a visual inspection of the motor/generator. \n \nThe Contractor must furnish the load bank and make the necessary cable connections from the generator to the load bank. This may require parallel runs of cabling. In some locations, this may require barricades, safety cones or both.  \n \nWork shall be conducted on weekdays (Monday through Friday), between 6:00 a.m. to 4:00 p.m. Work shall not occur on Government holidays. \n \nThe work performed shall not interrupt any power to the buildings identified in this Statement of Work. \n  \nPLACE OF PERFORMANCE: The generators listed in section C above are located at the following two locations: \n  Department of Veterans Affairs \nNew York Harbor Healthcare System   Brooklyn Campus \n800 Poly Place \nBrooklyn, NY 11209 \n \nDepartment of Veterans Affairs \nNew York Harbor Healthcare System   St. Albans CLC 179-00 Linden Blvd. Jamaica, NY 11425 \n \nAll required deliveries are to be delivered to the warehouse/loading dock at the respective locations. \n \nPERIOD OF PERFORMANCE: The Annual Load Bank Testing service shall be completed within 30 days of notice of award. This requirement is a one-time service and does include option years. \n   \nTYPE OF CONTRACT: \nThe government anticipates award of a firm fixed-priced contract. \n\nSAFETY: \nAll work shall comply with OSHA safety standards, Joint Commission (JTC), NFPA 110 and NFPA 70/NEC. \n \nCONTRACTOR QUALIFICATIONS: \n \nThe Contractor shall have safety training   either on-the-job or classroom type in electrical safety outlined in the OSHA Standard 29 Code of Federal Regulations (CFR) 1910 Subpart S   Electrical and NFPA 70E   Standard of Electrical Safety in the Workplace. Training certifications shall be submitted to the VA Contracting Officer prior to work. If no training certificates are available, the Contractor s employer shall certify that the service technician has met this requirement and submit it to the VA Contracting Officer. \n \nACCEPTANCE: \nVA personnel and Contractor personnel shall inspect the generators prior to the Contractor personnel leaving the facility. No invoices will be processed for payment in the absence of completion of the POC inspection. The Contractor shall provide a complete written report of the load banking for each generator. Information in the report shall have the following data: \n \nCompany s name, address, telephone number and fax number. \nName and signature of Contractors who performed the load bank. \nVA purchase order number or Contract Number. \nDate and time of work. \nGenerator building number. \nGenerator model, Engine model, Nameplate rating.  \nThe fifteen-minute interval log that was recorded during the load bank. \nDescription of generator condition and any deficiencies, if any. \n \nWARRANTY: \nThe contractor shall guarantee that all work performed will be free from all defects in workmanship and materials and that all services and repairs will provide the capacities and characteristics specified. The contract further guarantees that if, during a period of one year from the date of the certificate of completion and acceptance of the work, any such defects will be repaired by the Contractor at his/her own cost.","text":"Sources Sought Notice\n\nThis is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law.\n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Albany, NY for the purpose of collecting information about Brooklyn & Saint Albans Annual Generator Load Bank Testing at The New York Harbor Healthcare System - Brooklyn Campus 800 Poly Place Brooklyn, NY 11209 and New York Harbor Healthcare System St. Albans CLC 179-00 Linden Blvd. Jamaica, NY 11425. The VA is seeking to provide for this requirement as one time service. The NAICS code identified for this requirement is 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. The requirement is detailed in the draft Statement of Work section of this document.\n\n(e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service or providing for these items, are encouraged to email a capability statement and full information to Anthony Murray at Anthony.Murray2@va.gov and Charles Collins at Charles.Collins@va.gov.\n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, DUNS number and address, point of contact and social-economic. Interested Parties must also provide documentation such as certification and training for staff that demonstrates that they are an authorized solution distributor and/or authorized service technicians. Respondents who fail to provide the information request in the paragraph may be deemed non-responsive and incapable of meeting the government need.\nIf contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy.\n\nThe following information is required for determining procurement strategy and viability of sources:\nSet aside requirements have limitations on subcontracting and must be adherent to the Limitation on Subcontracting under FAR 19 and the Buy American Act (BAA) for commercial product procurements. This procurement is located in Brooklyn, New York and Jamaica, NY. Provide your supporting documentation to support your capability on adherence to Limitations on Subcontracting IAW FAR 19.505(b)(1) and VAAR 819.70 as prescribed in VAAR 852.219-75.\nIf your intention is to subcontract work, what tasks will be performed by you as the prime contractor?\nWhat tasks will require a subcontractor due to your inability to perform them within your company?\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired equipment or supplies.\n- Contractors shall identify pertinent point of contact for company, contractor DUNS number for size standard and socioeconomic verification in SAM and VIP, as well as for any intended subcontractors.\n- Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include letters from Original Equipment Manufacturers (OEM) if your firm is an authorized distributor.\n- Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded.\n- Contractors shall include any relevant comments about the Attachment(s) if applicable.\n\nStatement of Work\n\nTITLE: Generator Annual Testing and Corrective Repair Service\n\nBACKGROUND: The Department of Veterans Affairs, New York Harbor Healthcare System Engineering Service seeks to acquire testing and annual service for fifteen (15) generators listed herein. All work will be performed in compliance with Joint Commission (JTC) and National Fire Protection Association (NFPA) 110 requirements. The Brooklyn campus and St. Albans CLC generators are designed to provide back-up electrical power during an unforeseen outage of the primary electrical source and minimize additional disruptions to critical services.\n\nSCOPE: The Contractor shall provide qualified maintenance labor, equipment, tools, materials, parts, supplies, transportation, supervision, any other items, and non-personal services deemed necessary to perform load bank testing services on the following fifteen generators and provide any corrective maintenance repairs on any issues identified:\nST ALBANS CLC\n\nEquipment\nLocation\nMake\nModel\nSerial No.\nPM\nFrequency\nEmergency\nDiesel\nGenerators\nBldg. 64 Boiler Plant Upper Level\nCaterpillar 300KW\nC9\nCAT000C9E NGP00992\nAnnual\nBldg. 64 Boiler Plant Lower Level\nCaterpillar 1000KW\nC32\nJSJ03348\nAnnual\nBldg. 174 (serves\nBldg. 173 - Laundry)\nCaterpillar 750KW\nC27\n2A300225\nAnnual\nBldg. 167 (serves Bldgs. 85-87)\nCaterpillar 150KW\nD150-10\nCAT00C71LL 7C00429\nAnnual\nBldg. 88 (serves Commissary)\nCaterpillar 500KW\nC15\nCAT00C15K NAP0599\nAnnual\n\nBldg. 88 (serves\nDomiciliary area)\nCaterpillar 200KW\nD200-2\nCAT00C71CE\nTG00540\nAnnual\nBldg. 89 Basement\nCaterpillar 150KW\nD150-10\nCAT00C71V\nL7C00430\nAnnual\nBldg. 168 (serves Bldgs. 91-93)\nCaterpillar 150KW\nD150-10\nCAT00C71A\nL7C00428\nAnnual\nEmergency\nGas\nGenerators\nGuard Shack (Police)\nCaterpillar 150KW\nDG 30-2\nCAT00G30A NB W00138\nAnnual\nPump Station\nCaterpillar 300KW\nG300LG 6\nGXJ04856-\nOLY00000\nAnnual\n\nBROOKLYN CAMPUS\n\nEquipment\nLocation\nMake/Rating\nModel\nSerial No.\nPM\nFrequency\nEmergency\nDiesel\nGenerators\nMain Generator\nMain Generator\nCaterpillar 2025KW\n3516B\nYAT00416\nAnnual\nBldg. 4 (Engineering)\nA-Board Generator\nCaterpillar 2200KW\n3516B\n1HN00551\nAnnual\nOutpatient Clinic Generator\nOPC Generator Caterpillar\n600KW\n3508\n23Z06777\nAnnual\nBuilding 14 (Data Center)\nBldg. 14 Data Center\nGenerator Caterpillar\n400KW\n3456\nCER00472\nAnnual\nBuilding 13\nBldg. 13 Critical Care\nGenerator MTU Onsite\nEnergy 250KW\n6R1600\nDS250\n16301004459\nAnnual\n\nTASKS:\nThe Contractor must provide all labor and equipment to accomplish the task of annual load bank testing of fifteen generators and provide comprehensive reports upon completion.\n\nThe Contractor must meet the Joint Commission s requirements for load banking testing as follows:\n30% of nameplate rating for 2 hours, followed by\n50% of nameplate rating for 1 hour, followed by\n75% of nameplate ratings for 1 hour, plus warm up and cool down time for a total continuous run of 4 hours.\n\nThe Contractor must keep a written record of each generator run. The Contractor report include the following readings:\nAt 15-minute intervals,\nLube Oil Pressure\nWater Temperature\nExhaust Temperature\nAmperes\nVolts\nFrequency\n\nThe report must contain certification statements that each generator was load bank tested in accordance with original equipment manufacturer s requirements.\n\nContractor must provide a report of any corrective maintenance or repair services that will be needed to complete the load bank testing, should any arise. The Contracting Officer will review the report with the facility Point of Contact (POC) and make a determination as to a strategy to accomplish corrective repair and maintenance. Should the Contracting Officer determine that the best value to the government comes from allowing the Contractor to perform corrective maintenance and repair, then a price quote will be requested and the changes in work will be effected via a written modification from the Contracting Officer. No other person has the agency to authorize such a change.\n\nIf these circumstances result in a need to extend the contract the agreed upon extension period will be included in a modification.\n\nGENERAL REQUIREMENTS:\nA post-award site visit must be conducted by the contractor to determine parking, pathways, and proper connections to the generator units.\n\nThe Contractor must contact the maintenance supervisor of each site to schedule the load bank test and annual service. Supervisors contact information can be found under VA Engineering Service Point of Contact section herewith.\n\nPrior to starting the generators, the Contractor must perform a pre-run inspection to include checking the oil level, coolant level and a visual inspection of the motor/generator.\n\nThe Contractor must furnish the load bank and make the necessary cable connections from the generator to the load bank. This may require parallel runs of cabling. In some locations, this may require barricades, safety cones or both.\n\nWork shall be conducted on weekdays (Monday through Friday), between 6:00 a.m. to 4:00 p.m. Work shall not occur on Government holidays.\n\nThe work performed shall not interrupt any power to the buildings identified in this Statement of Work.\n\nPLACE OF PERFORMANCE: The generators listed in section C above are located at the following two locations:\nDepartment of Veterans Affairs\nNew York Harbor Healthcare System Brooklyn Campus\n800 Poly Place\nBrooklyn, NY 11209\n\nDepartment of Veterans Affairs\nNew York Harbor Healthcare System St. Albans CLC 179-00 Linden Blvd. Jamaica, NY 11425\n\nAll required deliveries are to be delivered to the warehouse/loading dock at the respective locations.\n\nPERIOD OF PERFORMANCE: The Annual Load Bank Testing service shall be completed within 30 days of notice of award. This requirement is a one-time service and does include option years.\n\nTYPE OF CONTRACT:\nThe government anticipates award of a firm fixed-priced contract.\n\nSAFETY:\nAll work shall comply with OSHA safety standards, Joint Commission (JTC), NFPA 110 and NFPA 70/NEC.\n\nCONTRACTOR QUALIFICATIONS:\n\nThe Contractor shall have safety training either on-the-job or classroom type in electrical safety outlined in the OSHA Standard 29 Code of Federal Regulations (CFR) 1910 Subpart S Electrical and NFPA 70E Standard of Electrical Safety in the Workplace. Training certifications shall be submitted to the VA Contracting Officer prior to work. If no training certificates are available, the Contractor s employer shall certify that the service technician has met this requirement and submit it to the VA Contracting Officer.\n\nACCEPTANCE:\nVA personnel and Contractor personnel shall inspect the generators prior to the Contractor personnel leaving the facility. No invoices will be processed for payment in the absence of completion of the POC inspection. The Contractor shall provide a complete written report of the load banking for each generator. Information in the report shall have the following data:\n\nCompany s name, address, telephone number and fax number.\nName and signature of Contractors who performed the load bank.\nVA purchase order number or Contract Number.\nDate and time of work.\nGenerator building number.\nGenerator model, Engine model, Nameplate rating.\nThe fifteen-minute interval log that was recorded during the load bank.\nDescription of generator condition and any deficiencies, if any.\n\nWARRANTY:\nThe contractor shall guarantee that all work performed will be free from all defects in workmanship and materials and that all services and repairs will provide the capacities and characteristics specified. The contract further guarantees that if, during a period of one year from the date of the certificate of completion and acceptance of the work, any such defects will be repaired by the Contractor at his/her own cost.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24225Q0344","place_of_performance":{"zip":"11209","city":{"code":"10011","name":"Brooklyn"},"state":{"code":"NY","name":"New York"},"street":"New York Harbor Healthcare System Brooklyn Campus","country":{"code":"USA","name":"UNITED STATES"},"street2":"800 Poly Place"},"product_service_code":"J061"}],"due_at":"2025-02-18T17:00:00Z","due_date":"2025-02-18","closes_at":"2025-02-18T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36047","county_name":"Kings County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-22T13:05:06.200863Z","principal_notice_id":"b88b76fb93cd4b1585d58adbb77800ba","description":{"text":"Sources Sought Notice\n\nThis is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law.\n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Albany, NY for the purpose of collecting information about Brooklyn & Saint Albans Annual Generator Load Bank Testing at The New York Harbor Healthcare System - Brooklyn Campus 800 Poly Place Brooklyn, NY 11209 and New York Harbor Healthcare System St. Albans CLC 179-00 Linden Blvd. Jamaica, NY 11425. The VA is seeking to provide for this requirement as one time service. The NAICS code identified for this requirement is 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance. The requirement is detailed in the draft Statement of Work section of this document.\n\n(e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service or providing for these items, are encouraged to email a capability statement and full information to Anthony Murray at Anthony.Murray2@va.gov and Charles Collins at Charles.Collins@va.gov.\n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, DUNS number and address, point of contact and social-economic. Interested Parties must also provide documentation such as certification and training for staff that demonstrates that they are an authorized solution distributor and/or authorized service technicians. Respondents who fail to provide the information request in the paragraph may be deemed non-responsive and incapable of meeting the government need.\nIf contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy.\n\nThe following information is required for determining procurement strategy and viability of sources:\nSet aside requirements have limitations on subcontracting and must be adherent to the Limitation on Subcontracting under FAR 19 and the Buy American Act (BAA) for commercial product procurements. This procurement is located in Brooklyn, New York and Jamaica, NY. Provide your supporting documentation to support your capability on adherence to Limitations on Subcontracting IAW FAR 19.505(b)(1) and VAAR 819.70 as prescribed in VAAR 852.219-75.\nIf your intention is to subcontract work, what tasks will be performed by you as the prime contractor?\nWhat tasks will require a subcontractor due to your inability to perform them within your company?\n- Contractors shall also identify any Federal Supply Schedules that may carry the desired equipment or supplies.\n- Contractors shall identify pertinent point of contact for company, contractor DUNS number for size standard and socioeconomic verification in SAM and VIP, as well as for any intended subcontractors.\n- Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include letters from Original Equipment Manufacturers (OEM) if your firm is an authorized distributor.\n- Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded.\n- Contractors shall include any relevant comments about the Attachment(s) if applicable.\n\nStatement of Work\n\nTITLE: Generator Annual Testing and Corrective Repair Service\n\nBACKGROUND: The Department of Veterans Affairs, New York Harbor Healthcare System Engineering Service seeks to acquire testing and annual service for fifteen (15) generators listed herein. All work will be performed in compliance with Joint Commission (JTC) and National Fire Protection Association (NFPA) 110 requirements. The Brooklyn campus and St. Albans CLC generators are designed to provide back-up electrical power during an unforeseen outage of the primary electrical source and minimize additional disruptions to critical services.\n\nSCOPE: The Contractor shall provide qualified maintenance labor, equipment, tools, materials, parts, supplies, transportation, supervision, any other items, and non-personal services deemed necessary to perform load bank testing services on the following fifteen generators and provide any corrective maintenance repairs on any issues identified:\nST ALBANS CLC\n\nEquipment\nLocation\nMake\nModel\nSerial No.\nPM\nFrequency\nEmergency\nDiesel\nGenerators\nBldg. 64 Boiler Plant Upper Level\nCaterpillar 300KW\nC9\nCAT000C9E NGP00992\nAnnual\nBldg. 64 Boiler Plant Lower Level\nCaterpillar 1000KW\nC32\nJSJ03348\nAnnual\nBldg. 174 (serves\nBldg. 173 - Laundry)\nCaterpillar 750KW\nC27\n2A300225\nAnnual\nBldg. 167 (serves Bldgs. 85-87)\nCaterpillar 150KW\nD150-10\nCAT00C71LL 7C00429\nAnnual\nBldg. 88 (serves Commissary)\nCaterpillar 500KW\nC15\nCAT00C15K NAP0599\nAnnual\n\nBldg. 88 (serves\nDomiciliary area)\nCaterpillar 200KW\nD200-2\nCAT00C71CE\nTG00540\nAnnual\nBldg. 89 Basement\nCaterpillar 150KW\nD150-10\nCAT00C71V\nL7C00430\nAnnual\nBldg. 168 (serves Bldgs. 91-93)\nCaterpillar 150KW\nD150-10\nCAT00C71A\nL7C00428\nAnnual\nEmergency\nGas\nGenerators\nGuard Shack (Police)\nCaterpillar 150KW\nDG 30-2\nCAT00G30A NB W00138\nAnnual\nPump Station\nCaterpillar 300KW\nG300LG 6\nGXJ04856-\nOLY00000\nAnnual\n\nBROOKLYN CAMPUS\n\nEquipment\nLocation\nMake/Rating\nModel\nSerial No.\nPM\nFrequency\nEmergency\nDiesel\nGenerators\nMain Generator\nMain Generator\nCaterpillar 2025KW\n3516B\nYAT00416\nAnnual\nBldg. 4 (Engineering)\nA-Board Generator\nCaterpillar 2200KW\n3516B\n1HN00551\nAnnual\nOutpatient Clinic Generator\nOPC Generator Caterpillar\n600KW\n3508\n23Z06777\nAnnual\nBuilding 14 (Data Center)\nBldg. 14 Data Center\nGenerator Caterpillar\n400KW\n3456\nCER00472\nAnnual\nBuilding 13\nBldg. 13 Critical Care\nGenerator MTU Onsite\nEnergy 250KW\n6R1600\nDS250\n16301004459\nAnnual\n\nTASKS:\nThe Contractor must provide all labor and equipment to accomplish the task of annual load bank testing of fifteen generators and provide comprehensive reports upon completion.\n\nThe Contractor must meet the Joint Commission s requirements for load banking testing as follows:\n30% of nameplate rating for 2 hours, followed by\n50% of nameplate rating for 1 hour, followed by\n75% of nameplate ratings for 1 hour, plus warm up and cool down time for a total continuous run of 4 hours.\n\nThe Contractor must keep a written record of each generator run. The Contractor report include the following readings:\nAt 15-minute intervals,\nLube Oil Pressure\nWater Temperature\nExhaust Temperature\nAmperes\nVolts\nFrequency\n\nThe report must contain certification statements that each generator was load bank tested in accordance with original equipment manufacturer s requirements.\n\nContractor must provide a report of any corrective maintenance or repair services that will be needed to complete the load bank testing, should any arise. The Contracting Officer will review the report with the facility Point of Contact (POC) and make a determination as to a strategy to accomplish corrective repair and maintenance. Should the Contracting Officer determine that the best value to the government comes from allowing the Contractor to perform corrective maintenance and repair, then a price quote will be requested and the changes in work will be effected via a written modification from the Contracting Officer. No other person has the agency to authorize such a change.\n\nIf these circumstances result in a need to extend the contract the agreed upon extension period will be included in a modification.\n\nGENERAL REQUIREMENTS:\nA post-award site visit must be conducted by the contractor to determine parking, pathways, and proper connections to the generator units.\n\nThe Contractor must contact the maintenance supervisor of each site to schedule the load bank test and annual service. Supervisors contact information can be found under VA Engineering Service Point of Contact section herewith.\n\nPrior to starting the generators, the Contractor must perform a pre-run inspection to include checking the oil level, coolant level and a visual inspection of the motor/generator.\n\nThe Contractor must furnish the load bank and make the necessary cable connections from the generator to the load bank. This may require parallel runs of cabling. In some locations, this may require barricades, safety cones or both.\n\nWork shall be conducted on weekdays (Monday through Friday), between 6:00 a.m. to 4:00 p.m. Work shall not occur on Government holidays.\n\nThe work performed shall not interrupt any power to the buildings identified in this Statement of Work.\n\nPLACE OF PERFORMANCE: The generators listed in section C above are located at the following two locations:\nDepartment of Veterans Affairs\nNew York Harbor Healthcare System Brooklyn Campus\n800 Poly Place\nBrooklyn, NY 11209\n\nDepartment of Veterans Affairs\nNew York Harbor Healthcare System St. Albans CLC 179-00 Linden Blvd. Jamaica, NY 11425\n\nAll required deliveries are to be delivered to the warehouse/loading dock at the respective locations.\n\nPERIOD OF PERFORMANCE: The Annual Load Bank Testing service shall be completed within 30 days of notice of award. This requirement is a one-time service and does include option years.\n\nTYPE OF CONTRACT:\nThe government anticipates award of a firm fixed-priced contract.\n\nSAFETY:\nAll work shall comply with OSHA safety standards, Joint Commission (JTC), NFPA 110 and NFPA 70/NEC.\n\nCONTRACTOR QUALIFICATIONS:\n\nThe Contractor shall have safety training either on-the-job or classroom type in electrical safety outlined in the OSHA Standard 29 Code of Federal Regulations (CFR) 1910 Subpart S Electrical and NFPA 70E Standard of Electrical Safety in the Workplace. Training certifications shall be submitted to the VA Contracting Officer prior to work. If no training certificates are available, the Contractor s employer shall certify that the service technician has met this requirement and submit it to the VA Contracting Officer.\n\nACCEPTANCE:\nVA personnel and Contractor personnel shall inspect the generators prior to the Contractor personnel leaving the facility. No invoices will be processed for payment in the absence of completion of the POC inspection. The Contractor shall provide a complete written report of the load banking for each generator. Information in the report shall have the following data:\n\nCompany s name, address, telephone number and fax number.\nName and signature of Contractors who performed the load bank.\nVA purchase order number or Contract Number.\nDate and time of work.\nGenerator building number.\nGenerator model, Engine model, Nameplate rating.\nThe fifteen-minute interval log that was recorded during the load bank.\nDescription of generator condition and any deficiencies, if any.\n\nWARRANTY:\nThe contractor shall guarantee that all work performed will be free from all defects in workmanship and materials and that all services and repairs will provide the capacities and characteristics specified. The contract further guarantees that if, during a period of one year from the date of the certificate of completion and acceptance of the work, any such defects will be repaired by the Contractor at his/her own cost.","html":"Sources Sought Notice\n\nThis is a Sources Sought Notice\n\n(a) The Government does not intend to award a contract on the basis of this Sources Sought or to otherwise pay for the information solicited.\n\n(b) Although \"proposal,\" \"offeror,\" contractor, and \"offeror\" may be used in this sources sought notice, any response will be treated as information only. It shall not be used as a proposal. The Government is seeking information for market research purposes only.\n\n(c) Any information received from a contractor in response to this Sources Sought may be used in creating a solicitation. Any information received which is marked with a statement, such as \"proprietary\" or \"confidential,\" intended to restrict distribution will not be distributed outside of the Government, except as required by law. \n\n(d) This Sources Sought is issued by VISN 2 Contracting Office in Albany, NY for the purpose of collecting information about Brooklyn & Saint Albans Annual Generator Load Bank Testing at The New York Harbor Healthcare System - Brooklyn Campus 800 Poly Place Brooklyn, NY 11209 and New York Harbor Healthcare System   St. Albans CLC 179-00 Linden Blvd. Jamaica, NY 11425. The VA is seeking to provide for this requirement as one time service.  The NAICS code identified for this requirement is 811310 Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance.  The requirement is detailed in the draft Statement of Work section of this document. \n\n(e) Cursory market research has identified small businesses that may be able to provide for this requirement. Contractors that are able to meet the requirements in the attachment and possess an interest in performing these service or providing for these items, are encouraged to email a capability statement and full information to Anthony Murray at Anthony.Murray2@va.gov and Charles Collins at Charles.Collins@va.gov. \n\n- Part of the purpose of this sources sought is to determine the viability of set aside to a specific socio-economic category(service-disabled veteran owned small business, veteran owned small business, women owned small business, HUB Zone, 8(a), small business). Interested parties MUST provide company/individual name, a capability statement, examples of same or similar work performed at other facilities, DUNS number and address, point of contact and social-economic. Interested Parties must also provide documentation such as certification and training for staff that  demonstrates that they are an authorized solution distributor and/or authorized service technicians. Respondents who fail to provide the information request in the paragraph may be deemed non-responsive and incapable of meeting the government need. \n If contractor is a Service-Disabled Veteran-Owned Small Business (SDVOSB), a Veteran-Owned Small Business (VOSB), or any other special category of contractors, then contractor is responsible for providing documentation in support of this. This information will be used to determine the viability of a set aside for this requirement. If any of the requested information is not supplied with the response, this may result in the contractor not being considered in the Government s Procurement Strategy. \n\nThe following information is required for determining procurement strategy and viability of sources:\nSet aside requirements have limitations on subcontracting and must be adherent to the Limitation on Subcontracting  under FAR 19 and the Buy American Act (BAA) for commercial product procurements. This procurement is located in Brooklyn, New York and Jamaica, NY. Provide your supporting documentation to support your capability on adherence to Limitations on Subcontracting IAW FAR 19.505(b)(1) and VAAR 819.70 as prescribed in VAAR 852.219-75. \nIf your intention is to subcontract work, what tasks will be performed by you as the prime contractor? \nWhat tasks will require a subcontractor due to your inability to perform them within your company?  \n- Contractors shall also identify any Federal Supply Schedules that may carry the desired equipment or supplies. \n- Contractors shall identify pertinent point of contact for company, contractor DUNS number for size standard and socioeconomic verification in SAM and VIP, as well as for any intended subcontractors. \n - Contractor shall provide 2 to 3 instances of past experience which demonstrate that they are a firm regularly engaged in this type of work, to include letters from Original Equipment Manufacturers (OEM) if your firm is an authorized distributor. \n - Contractor shall provide a listing of any teaming agreements they intend to employ in the performance of this requirement if awarded. \n- Contractors shall include any relevant comments about the Attachment(s) if applicable. \n\n\n\n\n\nStatement of Work \n\nTITLE: Generator Annual Testing and Corrective Repair Service \n \nBACKGROUND: The Department of Veterans Affairs, New York Harbor Healthcare System Engineering Service seeks to acquire testing and annual service for fifteen (15) generators listed herein. All work will be performed in compliance with Joint Commission (JTC) and National Fire Protection Association (NFPA) 110 requirements.   The Brooklyn campus and St. Albans CLC generators are designed to provide back-up electrical power during an unforeseen outage of the primary electrical source and minimize additional disruptions to critical services. \n\nSCOPE: The Contractor shall provide qualified maintenance labor, equipment, tools, materials, parts, supplies, transportation, supervision, any other items, and non-personal services deemed necessary to perform load bank testing services on the following fifteen generators and provide any corrective maintenance repairs on any issues identified: \nST ALBANS CLC \n\n\n\n\nEquipment \nLocation \nMake \nModel \nSerial No. \nPM \nFrequency \nEmergency \nDiesel \nGenerators \nBldg. 64 Boiler Plant Upper Level \nCaterpillar 300KW \nC9 \nCAT000C9E NGP00992 \nAnnual \nBldg. 64 Boiler Plant Lower Level \nCaterpillar 1000KW \nC32 \nJSJ03348 \nAnnual \nBldg. 174 (serves \nBldg. 173 - Laundry) \nCaterpillar 750KW \nC27 \n2A300225 \nAnnual \nBldg. 167 (serves Bldgs. 85-87) \nCaterpillar 150KW \nD150-10 \nCAT00C71LL 7C00429 \nAnnual \nBldg. 88 (serves Commissary) \nCaterpillar 500KW \nC15 \nCAT00C15K NAP0599 \nAnnual \n\nBldg. 88 (serves \nDomiciliary area) \nCaterpillar 200KW \nD200-2 \nCAT00C71CE\nTG00540 \nAnnual \nBldg. 89 Basement \nCaterpillar 150KW \nD150-10 \nCAT00C71V\nL7C00430 \nAnnual \nBldg. 168 (serves Bldgs. 91-93) \nCaterpillar 150KW \nD150-10 \nCAT00C71A\nL7C00428 \nAnnual \nEmergency \nGas \nGenerators \nGuard Shack (Police) \nCaterpillar 150KW \nDG 30-2 \nCAT00G30A NB W00138 \nAnnual \nPump Station \nCaterpillar 300KW \nG300LG 6 \nGXJ04856-\nOLY00000 \nAnnual \n \n\nBROOKLYN CAMPUS \n\n\n\n\nEquipment \nLocation \nMake/Rating \nModel \nSerial No. \nPM \nFrequency \nEmergency \nDiesel \nGenerators \nMain Generator \nMain Generator \nCaterpillar 2025KW \n3516B \nYAT00416 \nAnnual \nBldg. 4 (Engineering) \nA-Board Generator \nCaterpillar 2200KW \n3516B \n1HN00551 \nAnnual \nOutpatient Clinic Generator \nOPC Generator Caterpillar \n600KW \n3508 \n23Z06777 \nAnnual \nBuilding 14 (Data Center) \nBldg. 14 Data Center \nGenerator Caterpillar \n400KW \n3456 \nCER00472 \nAnnual \nBuilding 13 \nBldg. 13 Critical Care \nGenerator MTU Onsite \nEnergy 250KW \n6R1600 \nDS250 \n16301004459 \nAnnual \n \nTASKS: \nThe Contractor must provide all labor and equipment to accomplish the task of annual load bank testing of fifteen generators and provide comprehensive reports upon completion.  \n \nThe Contractor must meet the Joint Commission s requirements for load banking testing as follows: \n30% of nameplate rating for 2 hours, followed by \n50% of nameplate rating for 1 hour, followed by \n75% of nameplate ratings for 1 hour, plus warm up and cool down time for a total continuous run of 4 hours.  \n \nThe Contractor must keep a written record of each generator run. The Contractor report include the following readings:  \nAt 15-minute intervals, \nLube Oil Pressure \nWater Temperature \nExhaust Temperature \nAmperes \nVolts \nFrequency \n \nThe report must contain certification statements that each generator was load bank tested in accordance with original equipment manufacturer s requirements. \n\nContractor must provide a report of any corrective maintenance or repair services that will be needed to complete the load bank testing, should any arise. The Contracting Officer will review the report with the facility Point of Contact (POC) and make a determination as to a strategy to accomplish corrective repair and maintenance. Should the Contracting Officer determine that the best value to the government comes from allowing the Contractor to perform corrective maintenance and repair, then a price quote will be requested and the changes in work will be effected via a written modification from the Contracting Officer. No other person has the agency to authorize such a change. \n\nIf these circumstances result in a need to extend the contract the agreed upon extension period will be included in a modification. \n\nGENERAL REQUIREMENTS: \nA post-award site visit must be conducted by the contractor to determine parking, pathways, and proper connections to the generator units.  \n\nThe Contractor must contact the maintenance supervisor of each site to schedule the load bank test and annual service. Supervisors contact information can be found under VA Engineering Service Point of Contact section herewith. \n \nPrior to starting the generators, the Contractor must perform a pre-run inspection to include checking the oil level, coolant level and a visual inspection of the motor/generator. \n \nThe Contractor must furnish the load bank and make the necessary cable connections from the generator to the load bank. This may require parallel runs of cabling. In some locations, this may require barricades, safety cones or both.  \n \nWork shall be conducted on weekdays (Monday through Friday), between 6:00 a.m. to 4:00 p.m. Work shall not occur on Government holidays. \n \nThe work performed shall not interrupt any power to the buildings identified in this Statement of Work. \n  \nPLACE OF PERFORMANCE: The generators listed in section C above are located at the following two locations: \n  Department of Veterans Affairs \nNew York Harbor Healthcare System   Brooklyn Campus \n800 Poly Place \nBrooklyn, NY 11209 \n \nDepartment of Veterans Affairs \nNew York Harbor Healthcare System   St. Albans CLC 179-00 Linden Blvd. Jamaica, NY 11425 \n \nAll required deliveries are to be delivered to the warehouse/loading dock at the respective locations. \n \nPERIOD OF PERFORMANCE: The Annual Load Bank Testing service shall be completed within 30 days of notice of award. This requirement is a one-time service and does include option years. \n   \nTYPE OF CONTRACT: \nThe government anticipates award of a firm fixed-priced contract. \n\nSAFETY: \nAll work shall comply with OSHA safety standards, Joint Commission (JTC), NFPA 110 and NFPA 70/NEC. \n \nCONTRACTOR QUALIFICATIONS: \n \nThe Contractor shall have safety training   either on-the-job or classroom type in electrical safety outlined in the OSHA Standard 29 Code of Federal Regulations (CFR) 1910 Subpart S   Electrical and NFPA 70E   Standard of Electrical Safety in the Workplace. Training certifications shall be submitted to the VA Contracting Officer prior to work. If no training certificates are available, the Contractor s employer shall certify that the service technician has met this requirement and submit it to the VA Contracting Officer. \n \nACCEPTANCE: \nVA personnel and Contractor personnel shall inspect the generators prior to the Contractor personnel leaving the facility. No invoices will be processed for payment in the absence of completion of the POC inspection. The Contractor shall provide a complete written report of the load banking for each generator. Information in the report shall have the following data: \n \nCompany s name, address, telephone number and fax number. \nName and signature of Contractors who performed the load bank. \nVA purchase order number or Contract Number. \nDate and time of work. \nGenerator building number. \nGenerator model, Engine model, Nameplate rating.  \nThe fifteen-minute interval log that was recorded during the load bank. \nDescription of generator condition and any deficiencies, if any. \n \nWARRANTY: \nThe contractor shall guarantee that all work performed will be free from all defects in workmanship and materials and that all services and repairs will provide the capacities and characteristics specified. The contract further guarantees that if, during a period of one year from the date of the certificate of completion and acceptance of the work, any such defects will be repaired by the Contractor at his/her own cost.","origin":"detail"},"contacts":[{"name":"Charles Collins","role":"primary","email":"Charles.Collins@va.gov","phone":"518-626-7200","title":"Contracting Officer"}],"place_of_performance":{"zip":"11209","city":{"code":"10011","name":"Brooklyn"},"state":{"code":"NY","name":"New York"},"street":"New York Harbor Healthcare System Brooklyn Campus","country":{"code":"USA","name":"UNITED STATES"},"street2":"800 Poly Place"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"f1f46f4298ea492c84932658324e5a42","name":"36C24225Q0344.docx","kind":"file","mime_type":".docx","size_bytes":28885,"posted_at":"2025-02-12T18:38:47.826Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f1f46f4298ea492c84932658324e5a42/download","mirrored":false},{"resource_id":"6d6f56b9dc9743a1b2ddfc6f00ab478a","name":"Dept of Veterans Affairs","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-02-12T18:38:47.826Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov","mirrored":false}],"awards":[],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"30199PR270000005","latest_notice_id":"1ad4aa3bb86b47ff8abc3eda4aa226fa","title":"USCG Station Fire Island Attic Vents","solicitation_number":"30199PR270000005","notice_type":"o","first_type":"o","first_posted":"2026-11-12","last_posted":"2026-11-24","notices":3,"due_at":"2026-11-30T05:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T05:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL14","office_name":"BASE BOSTON","naics":"811310","psc":"J039","set_aside":null,"state":"NY","county":"36103","county_name":"Suffolk County","city":"3603408","city_name":"Babylon","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"W911PT27QA029","latest_notice_id":"b44bd4dff4c2421abc7e475d27c14cd2","title":"Cryogenic Regulator Manifold Installation","solicitation_number":"W911PT27QA029","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T18:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"811310","psc":"R699","set_aside":null,"state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"THE BULKNITROGEN/ARGON AREA OF THE WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"QSE36C78626Q50013","latest_notice_id":"46f855d809c042bb9b91202e7af224ee","title":"Combined Synopsis Solicitation - 36C78626Q50013 - HVAC and BMS Maintenance Services for Calverton National Cemetery -- J041","solicitation_number":"QSE--36C78626Q50013","notice_type":"k","first_type":"k","first_posted":"2025-12-03","last_posted":"2025-12-03","notices":1,"due_at":null,"due_date":"2026-12-29","closes_at":"2026-12-30T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C786","office_name":"NATIONAL CEMETERY ADMIN (36C786)","naics":"811310","psc":"J041","set_aside":"SBA","state":"NY","county":"36103","county_name":"Suffolk County","city":"3611781","city_name":"Calverton","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Calverton National Cemetery","site_key":"calverton-national-cemetery-ny","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-10-20T03:44:24.781460Z"}],"similar_open_total":57,"indexable":false}