{"canonical":"https://sealedbidder.com/opportunities/36c24225q0222","key":"36C24225Q0222","url":"https://sealedbidder.com/opportunities/36c24225q0222","title":"H266--Testing of Sterile Compounding Areas","solicitation_number":"36C24225Q0222","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-01-30T17:00:00Z","first_posted":"2025-01-23","last_posted":"2025-01-23","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541380","psc":"H266","set_aside":null,"place_state":"NY","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"36103","place_county_name":"Suffolk County","place_city":"3653396","place_city_name":"Northport","winner":null,"award_amount":null,"publications":[{"notice_id":"55f17ccba1654d53be14ed8104472cb3","title":"H266--Testing of Sterile Compounding Areas","solicitation_number":"36C24225Q0222","notice_type":"o","base_type":"p","posted":"2025-01-23","posted_at":"2025-01-23T15:00:34.696Z","due_at":"2025-01-09T17:00:00Z","due_date":"2025-01-09","cancelled":false,"archived":true,"archive_date":"2025-02-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/55f17ccba1654d53be14ed8104472cb3/view","enriched":true,"history":[{"index":6,"title":"H266--Testing of Sterile Compounding Areas","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-23T14:59:38.862Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"5f3ef90d5211405bb53103ed61c6f774","solicitation_number":"36C24225Q0222"},{"index":4,"title":"H266--Testing of Sterile Compounding Areas","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-23T15:00:34.696Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"55f17ccba1654d53be14ed8104472cb3","solicitation_number":"36C24225Q0222","related_opportunity_id":"5f3ef90d5211405bb53103ed61c6f774"}]},{"notice_id":"5f3ef90d5211405bb53103ed61c6f774","title":"H266--Testing of Sterile Compounding Areas","solicitation_number":"36C24225Q0222","notice_type":"p","base_type":"p","posted":"2025-01-23","posted_at":"2025-01-23T14:59:38.862Z","due_at":"2025-01-30T17:00:00Z","due_date":"2025-01-30","cancelled":false,"archived":true,"archive_date":"2025-03-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5f3ef90d5211405bb53103ed61c6f774/view","enriched":true,"history":[{"index":6,"title":"H266--Testing of Sterile Compounding Areas","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-23T14:59:38.862Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"5f3ef90d5211405bb53103ed61c6f774","solicitation_number":"36C24225Q0222"},{"index":4,"title":"H266--Testing of Sterile Compounding Areas","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-23T15:00:34.696Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"55f17ccba1654d53be14ed8104472cb3","solicitation_number":"36C24225Q0222","related_opportunity_id":"5f3ef90d5211405bb53103ed61c6f774"}]}],"latest_notice_id":"5f3ef90d5211405bb53103ed61c6f774","first_type":"o","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-01-23","posted_at":"2025-01-23T15:00:34.696Z","created_at":"2025-01-23T15:00:32.514Z","modified_at":"2025-02-09T04:55:44.695Z","response_deadline":{"raw":"2025-01-09T12:00:00-05:00","utc":"2025-01-09T17:00:00Z","date":"2025-01-09","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/55f17ccba1654d53be14ed8104472cb3/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"H266--Testing of Sterile Compounding Areas","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-02-08","archive_type":"auto_custom"},"history":[{"index":6,"title":"H266--Testing of Sterile Compounding Areas","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-23T14:59:38.862Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"5f3ef90d5211405bb53103ed61c6f774","solicitation_number":"36C24225Q0222"},{"index":4,"title":"H266--Testing of Sterile Compounding Areas","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-23T15:00:34.696Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"55f17ccba1654d53be14ed8104472cb3","solicitation_number":"36C24225Q0222","related_opportunity_id":"5f3ef90d5211405bb53103ed61c6f774"}],"contacts":[{"name":"Lee T Kern (Contractor)","role":"primary","email":"Lee.Kern@va.gov","title":"Contractor Support"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"55f17ccba1654d53be14ed8104472cb3","lineage_id":"55f17ccba1654d53be14ed8104472cb3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T10:14:35.688483258Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4e50d584aaf04c65a3e3728d7a2c07febd621d9dc07e55b955fe7ccdbd27344f","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T10:14:35.688483258Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"This is a firm-fixed priced requirement to provide of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas at the at the Northport VAMC, 79 Middleville Road , Northport, NY 11768.","text":"This is a firm-fixed priced requirement to provide of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas at the at the Northport VAMC, 79 Middleville Road , Northport, NY 11768.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"36C24225Q0222","product_service_code":"H266"},{"award":{"awardee":{}},"dates":{"posted":"2025-01-23","posted_at":"2025-01-23T14:59:38.862Z","created_at":"2025-01-23T14:59:36.689Z","modified_at":"2025-03-01T05:04:24.737Z","response_deadline":{"raw":"2025-01-30T12:00:00-05:00","utc":"2025-01-30T17:00:00Z","date":"2025-01-30","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5f3ef90d5211405bb53103ed61c6f774/view"},"naics":{"codes":["541380"],"primary":"541380"},"title":"H266--Testing of Sterile Compounding Areas","agency":{"office":{"code":"36C242","name":"242-NETWORK CONTRACT OFFICE 02 (36C242)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"organization_id":"100186522","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-01","archive_type":"auto_custom"},"history":[{"index":6,"title":"H266--Testing of Sterile Compounding Areas","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-23T14:59:38.862Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"5f3ef90d5211405bb53103ed61c6f774","solicitation_number":"36C24225Q0222"},{"index":4,"title":"H266--Testing of Sterile Compounding Areas","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-23T15:00:34.696Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"55f17ccba1654d53be14ed8104472cb3","solicitation_number":"36C24225Q0222","related_opportunity_id":"5f3ef90d5211405bb53103ed61c6f774"}],"contacts":[{"name":"Lee Kern","role":"primary","email":"Lee.Kern@va.gov","phone":"607-664-4748","title":"Contract Specialist"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"5f3ef90d5211405bb53103ed61c6f774","lineage_id":"55f17ccba1654d53be14ed8104472cb3","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T10:20:29.476486193Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"40a9e6b8f3dbdaa1dc1a3b82d8517e50e57ae8d86f302ed13558e48173b73783","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T10:20:29.476486193Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"The Department of Veterans Affairs Network Contracting Office 2 is issuing this source sought synopsis as a means of conducting market research to identify parties having an interest in and the resources providing Testing of Sterile Compounding Areas at the Northport VAMC, 79 Middleville Road , Northport, NY 11768.\nThe result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 541380.\nThe VA requires a 12-month base year, plus four 12-month options contract. This contract will be inclusive of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. \nTelephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above listed services are invited to submit a response to this Sources Sought Notice by October 24, 2024, at 12:00PM EST. All responses under this Sources Sought Notice must be emailed to Lee.Kern@va.gov.\nPlease see the below Statement of Work (SOW):\nSTATEMENT OF WORK\nTesting of Sterile Compounding Areas\n\nINTRODUCTION\n United States Pharmacopeia (USP) establishes standards for cleanroom design, environmental monitoring, and competencies for the preparation, handling, and storage of compounded sterile preparations (CSPs).  To maintain compliance with these standards, Northport VAMC requires a Base plus four (4) year contract inclusive of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas. Certification and testing will consist of:\n testing all primary engineering controls [(PECs) e.g., biological safety cabinets (BSCs), laminar airflow workbenches (LAFWs), compounding aseptic containment isolators (CACI), and compounding aseptic isolators (CAI)]\ntesting all secondary engineering controls (SECs), non-ISO rated controlled non-classified (CNC) rooms, and High-efficiency particulate air (HEPA) filtration devices. \nmicrobiological laboratory testing of collected viables samples.\nwipe sampling for environmental Hazardous Drug (HD) residue\n\nTesting and certification must be completed in accordance with the most currently published versions of  USP Chapter <797> , USP Chapter <800>, Controlled Environment Testing Association (CETA) Application Guides for: CAG-003 Certification of Sterile Compounding Facilities for USP Compliance, CAG-002 Compounding Isolator Testing, CAG-008 Certification Matrix for\nSterile & Nonsterile USP Compounding Facilities, CAG-009 Viable Environmental Monitoring for Sterile Compounding Facilities, CAG-014 Airflow Visualization Study, National Sanitation Foundation/American National Standards Institute (NSF/ANSI) Standard 49 Biosafety Cabinetry, and Institute of Flow Clean Air Devices, IEST-RP-CC-002.4. All lab analysis of viable samples must be performed by a facility with ISO/IEC 17025 accreditation for microbial analysis. This environmental quality testing may not be performed under the laboratory s Clinical Laboratory Improvement Amendments (CLIA) license. The lab must attain ISO/IEC 17025 certification from an external accrediting body (e.g., American Association for Laboratory Accreditation ) to ensure quality and accuracy of the testing.\n\nBACKGROUND. \nNorthport VAMC is pursuing a facility contract for certification of all PECs, SECs, CNC rooms, and HEPA filters must be performed pursuant to the most current version of USP Chapter <797> and USP Chapter <800> standards following CETA s  standardized testing procedures which include (but is not limited to) CAG-003 CETA Certification Guide for Sterile Compounding Facilities for USP Compliance, CAG-002 CETA Compounding Isolator Testing Guide, CAG-014 Airflow Visualization Study, and CAG-009 Viable Environmental Monitoring for Sterile Compounding Facilities.\n \nCertification must be performed every 6 months. Recertification will be required after any servicing of facilities or equipment, post changes to the area that could affect airflow or air quality ( e.g., redesign,  construction, replacement or relocation of any PEC, or alteration in the configuration of the room), and/or in response to identified problems or trends.  \n\nCertification procedures defined in relevant CETA Application Guides must be  performed no less than every 6 months by an individual who has the required CETA competencies and training related to the certification of primary and secondary engineering controls. Additionally, it is preferred that the on-site certification individual have received NSF accreditation for the field certification of Class II Biosafety Cabinets and are accredited through CNBT as a registered certification professional in the sterile compounding facility (RCP-SCF). Prior to testing, the contractor s technician(s) who conduct on-site certification will provide, to the COR, documentation of competency and training related to the certification of PECs and SECs. \n\nProcedures for air and surface sampling and evaluation must be compliant as per the most current USP Chapter 797 requirements for environmental air sampling, surface sampling (CAG-009), gloved fingertip testing (CAG-011), and media fill testing (CAG-013) following the appropriate CETA CAG application guide.\n\nNorthport VAMC s sterile compounding areas and equipment must be compliant to The Joint Commission (TJC) and Food and Drug Administration (FDA) requirements. TJC Medication Compounding Requirements for Critical Access Hospitals and Hospitals, effective January 1, 2024, established new Medication Compounding (MC) standards for non-sterile and sterile compounded preparations which are based on USP standards.  The FDA has the authority to inspect VA medical facilities under the Food, Drug and Cosmetic Act, and evaluate based upon the guidance provided in the Insanitary Conditions at Compounding Facilities Guidance for Industry, November 2020 (or most current version).\n\nSCOPE \nTesting Frequency. \nThe Northport VAMC has a requirement for onsite initial and reoccurring CETA certification and viable environmental sampling of the facility s Pharmacy-specific and non-Pharmacy specific areas and equipment as detailed within this Statement of Work (SOW).  Testing and certification dates contained within this SOW are best documented; Contractor shall be responsible to confirm and/or adjust certification/testing requirements to ensure no lapse in requirements and thus no undesirable effect on the mission of the Northport VAMC.\nAll pharmacy-specific equipment will minimally obtain CETA certification every six (6) calendar months from the date of the last certification/testing of BSCs, LAFWs, CAI, CACI, HEPA filters, and room spaces/environments in accordance with VHA Directive 1108.12 (see attachment A), and USP 797 (Attachment B) & 800 (Attachment C). Recertification may be required sooner if equipment is relocated/altered, or a major service is performed.\n\nTesting Locations. The following location shall be tested as per USP 797 and where applicable USP 800 standards as per respective CETA guide applications. Locations may be amended as per the facility s renovations and construction.\nBuilding 200, Unit 31 Cleanroom suite(s) Primary Space(s) and equipment\nISO-8 Anteroom(s): Two ceiling mounted HEPA filters\nISO-7 Buffer room(s)\nTwo ceiling mounted HEPA filters\nOne ISO-5 LAWF: Baker Edgegard 5252 LAWF \nBuilding 200, Inpatient: One ISO-5 Compounding Aseptic Isolator (CAI): Baker SS-500\nBuilding 200, New pavilion 2F, E2-49\nHD negative pressure storage room: One ceiling mounted HEPA filter\nCNC HD negative pressure C-SCA\nOne ceiling mounted HEPA filter\nOne ISO-5 HD negative pressure Compounding Aseptic Containment Isolator (CACI): Baker CS-500\nGermFree Trailer (adjacent to building 11) - This location will be covered under this contract for monthly viable sampling and hazardous drug wipe sampling. \nNote: There is a separate contract which covers the semiannual CETA testing and viable sampling of the trailer.\n\nTesting Requirements of PECs.\nBiological safety cabinet (BSC): On-site certifications of the BSCs shall be tested to manufacturer specifications in accordance with the most recent version of NSF/ANSI Standard 49 Biosafety Cabinetry (as per CETA CAG-003:2022 section 8.2. through 8.2.5 application guide and CETA CAG-005:2007 (or most current versions)\nCompounding Aseptic Isolator (CAI) and Compounding Aseptic Containment Isolator (CACI):  The contractor shall test and certify all CAIs and CACIs as per CETA CAG-003 sections 8.3 through 8.3.5 and in accordance with CETA CAG-002 guide application. \nLaminar Air Flow Workbench (LAFW): The contractor shall test and certify all LAFW as per CETA CAG-003:2022 section 8.4. through 8.4.6 application guide (or most current version)\nThe contractor shall test and certify all PECs in accordance with the most current version of The Institute of Environmental Sciences and Technology (IEST)-RP-CC002 (Unidirectional Flow Clean-Air Devices), CETA CAG-003, and the manufacturer's specifications.\nThe contractor shall record each individual face velocity reading and the average of those readings, the downstream concentration reading of the HEPA filter leak test and the results of the induction leak test and back streaming test\nAll equipment used to certify PECs must be calibrated in accordance with IEST-RP-CC013 or manufacturer's recommendation and be NIST traceable where possible.\nWhere applicable the list of tests for PECs includes, where applicable but not limited to the following:\nAir flow velocity profile\nAir flow visualization profile: dynamic smoke pattern testing (video recorded and provided to us on a thumb drive or made available for download on a secure website) for all primary engineering controls. Tester must utilize sufficient smoke to demonstrate unidirectional airflow at critical sites and sweeping action over and away from preparations.\nPrefilter check\nHEPA/ULPA filter leak integrity testing (must be performed upon installation and as part of certification)\nInduction leak integrity test and patching if necessary\nElectrical leakage and ground circuit resistance and polarity tests\nPreparation ingress and egress test where applicable\nChamber pressure test\nTotal airborne non-viable particle count testing in all classified areas performed under dynamic operating conditions \nFor each PEC passing the required certification tests, the contractor supplies each unit with a certification tag or sticker displaying the following information:\nCompany name and contact information.\nUnit make, model and serial number.\nReport number\nLocation (e.g., building, room number, area identification)\nCertification date\nRecertification date\nTechnician name and signature\nAny PEC that fails to meet CETA specifications shall be clearly marked with signage which alerts compounding personnel that the unit is  out of order until further notice.  \n\nTesting Requirements of SECs.\nThe contractor will provide comprehensive cleanroom testing and certification services every 6 months, in the event of an environmental or engineering control excursion/exceedance or sooner if there are changes to the area such as redesign, construction, replacement or relocation of any PEC, or alteration in the configuration of the room that could affect airflow or air quality or if a cleanroom(s) did not meet compliance.  Certification tests for rooms within a cleanroom suite include, but are not limited to:\nAirflow testing: HEPA filter(s) air volumes and velocities will be measured and documented as per CETA CAG-003:2022 section 8.1.1 application guide (or most current version)\n Airflow testing is performed to determine acceptability of the air velocity, the room air exchange rate, and the room pressure differential in doorways between adjacent rooms to ensure consistent airflow and that the appropriate quality of air is maintained under dynamic operating conditions.\nThe contractor shall calculate the total room area and volume for each buffer room, anteroom, Containment segregated compounding area (C-SCA), and hazardous drug storage room. The ISO classification and a sketch of the room with dimensions, exhaust/supply diffuser locations and equipment locations shall be included in the report.  The report provided will specify flow rates detailing returns and supply that were obtained during the testing. The contractor shall calculate air changes per hour (ACPH) for each buffer and anteroom and include their findings in the report.  ACPH for HVAC, ACPH contributed from PEC, and the total ACPH. Comparison of ACPH will be completed both for USP 797 standards as well as those referenced in the VHA HVAC Design Manual (Attachment D or earlier version if available), which are further stringent than USP Chapter 797.\nISO Classified Turbulent Airflow Area Reporting and Documentation\nRecord all airflow measurements and their corresponding filter or diffuser locations or grid identifications on a diagram \nCalculate and report room volume \nCalculate and report the average total room airflow volume \nCalculate and report the total air changes per hour of the room (include LAFW and/or Non-ducted BSC HEPA exhaust to room, where applicable) \nReport any correction factors used or deviations from the primary method  \nName of test (e.g., Room Airflow Analysis) \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nNon-ISO Classified Negative Pressure Turbulent Airflow Area Testing Procedure including ACPH requirements for containment segregated compounding areas and  hazardous drug storage areas, must be a minimum of 12 exhaust ACPH. Because these rooms/areas are not ISO classified airflow measurements should be taken on the exhaust of negative pressure differential rooms. Non-ISO Classified Negative Pressure Turbulent Airflow Reporting and Documentation must include:\nRecord all airflow measurements and their corresponding exhaust filter or exhaust grill locations \nCalculate and report room volume \nCalculate and report the average total room airflow volume \nCalculate and report the total air changes per hour of the room  \nReport any correction factors used or deviations from the primary method  \nName of test (e.g., Unclassified Negative Pressure Room Airflow Analysis) \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nSEC HEPA filter integrity testing performed as per CETA CAG-003:2022 section 8.1.2 application guide (or most current version)\nRecord upstream aerosol challenge concentration \nList method used to report concentration (measured or calculated) \nRecord maximum leak penetration in percent \nName of test (HEPA Filter Leak Test) \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nSEC Room Pressure Differential/Room Pressurization as per CETA CAG-003:2022 section 8.1.3 application guide (or most current version)\nThe contractor shall include in their report differential pressure readings from each buffer room, anteroom, C-SCA, and Hazardous Drug (HD) storage rooms to all surrounding areas.\nThe report shall indicate whether the area is required to be a negative or positive pressure location as per USP 797 and/or USP 800. All readings and acceptance criteria shall be documented to at least one thousandths of an inch water gauge or water column (e.g., 0.020  w.g. and not 0.02  w.g.) or one tenth of a pascal (e.g., 5.0 Pa).  Pressure differentials will be reflected on a report showing the sketch of the room(s).\nSEC Room Pressure Reporting and Documentation\nReport room pressure differential relative to an adjacent room/space \nReport and compare performance of room pressure monitor \nReport whether smoke dispersed at entry doors follows correct direction \nName of test (Room Pressure Differential Test) \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nTotal airborne particle count testing (0.5 micron and larger) in all classified areas performed under dynamic operating conditions  as per CETA CAG-003:2022 section 8.1.5 application guide (or most current version). Reporting shall be completed following ISO 14644-01 [2015] section 5.4  Test report  and shall include the following:  \nThe name and address of the testing organization, and the date on which the test was performed \nThe number and year of publication of this part of ISO 14644 (i.e., ISO 14644 1:2015) \nA clear identification of the physical location of the cleanroom or clean zone  testing (including reference to adjacent areas if necessary), and specific  designations for coordinates of all sampling locations (a diagrammatic  representation can be helpful) \nThe specified designation criteria for the cleanroom or clean zone, including the ISO Class number, the relevant occupancy state(s), and the considered particle size(s) \nDetails of the test method used, with any special conditions relating to the test, or departures from the test method, and identification of the test instrument and its current calibration certificate \nThe test results, including particle concentration data for all sampling locations \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nSEC Airflow Visualization Studies (AVS) - Visual Smoke Studies per CETA CAG-014 guide application\nSEC General Temperature and Moisture Tests to verify accuracy of monitoring devices as per CETA CAG-003:2022 section 8.1.7 application guide (or most current version)\nSEC Viable Sampling as per CETA CAG-003:2022 section 8.1.6 and CAG-009:2020 application guides\n\nViable Sampling Testing  All viable sampling will conform to USP 797 requirements and performed as per CETA CAG-009 application guide Viable Environmental Monitoring for Sterile Compounding Facilities \nEnvironmental Air Sampling. \nBiannually (every six months) the collection of environmental air samples will be performed by the contractor s CETA technician during certification and during negatively impactful incidents which require repeat air sampling as follows:\nwhenever there is a change to the placement of equipment in the room or any other alteration within the cleanroom suite that affects the quality of the air.\nin response to identified problems and trends.\nin response to changes that could impact the sterile environment (changes in cleaning agents).\nViable air sampling will be performed utilizing a calibrated high-volume impaction sampler during dynamic operating conditions \n Single plate TSA media which supports growth of both bacteria and fungi will be used to sample.  A sufficient volume of air (1000 liters) shall be tested at each location to maximize sensitivity (samples of less than 1000 liters will not be acceptable)\nPositive and negative control plates will be included with sampled plates submitted by the contractor for analysis.\nEnvironmental Surface Sampling. \nBiannually (every six months) the collection of environmental surface samples will be performed by the contractor s CETA technician and during repeated CETA testing. Upon the request of the facility, the contractor will repeat surface sampling as follows:\nwhenever, there is a change to the placement of equipment in the room or any other alteration within the cleanroom suite that affects the quality of the air.\nin response to identified problems and trends.\nin response to changes that could impact the sterile environment (changes in cleaning agents).\nSurface samples will be collected in each room, the interior of each PEC, passthrough chambers connecting to classified areas, and frequently touched surfaces (e.g., door, tables, carts, stools, benches, etc.)  \nSurface sampling will be performed at the end of the largest CSP activity of the day but before area has been cleaned and disinfected.  \nSingle plate TSA media supplemented with neutralizing additives (e.g., lecithin and polysorbate 80) to neutralize the effects of any residual disinfecting agents will be used.\nRoutine monthly surface sampling will be performed by an appointed trained Northport VAMC personnel. The collected samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis.\nAs needed, appointed trained Northport VAMC personnel will collect surface samples within the PEC as a part of the competency assessment for assigned personnel. The collected samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis.\nPersonnel Viable Sampling.\n The collection of personnel viable samples for competency testing will be performed by an appointed trained Northport VAMC personnel. The samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis when it is required for personnel competency assessment sampling as follows:\nGloved Fingertip and Thumb (GFT) Testing \nUpon initial assignment compounding staff will be assessed, post hand hygiene and garbing, utilizing GFT samples in triplicate (three samples/hand) for analysis.\nEvery six (6) months and thereafter compounding staff will be assessed, post hand hygiene and garbing, utilizing single collection of GFT samples (one sample/hand) will be collected for analysis post hand hygiene and garbing.\nInitially and every six (6) months thereafter compounding staff will be assessed for GFT during aseptic manipulations, utilizing single collection of GFT samples (one sample/hand) post media fill testing (MFT).\nMedia Fill Test (MFT) \nUpon initial assignment and every six months thereafter,  compounding staff will be assessed  for aseptic manipulations utilizing USP 797 compliant media fill testing kits.\nOther Viable Sampling Requirements. \nThe laboratory service employed by the contractor must be able to provide the following:\nMicrobial growth media plates which are USP 797 compliant and\ninclude certificates of analysis (COA) from the manufacturer that verify the plates meet the expected growth promotion, pH, and sterilization requirements consistent with USP Chapter 797\ncontain TSA supplemented with neutralizing additives (lecithin and polysorbate 80)\nhave a raised convex surface\nsupport both bacterial and fungal growth on the same plate for single media incubation\nMedia fill testing (MFT) kits compliant to USP 797 and designed to\n simulate medium complexity (Category 2) sterile IV compounding.\nsimulate low complexity (Category 1) sterile IV compounding. \nA chain of custody documenting each sample collected must be created and provided to the Northport VAMC . \nDuring self-sampling, which is performed by Northport VAMC, the contracted lab is responsible for providing a prepaid mailer for properly sending samples to the laboratory for testing.\nAll samples shipped to the laboratory service must be incubated in accordance with current USP Chapter 797 requirements for duration and temperature.\nAdditional Requirements for PECs and/or SECs Testing\nAny PEC or SEC that fails to meet CETA specifications shall be immediately reported directly to the site-identified point(s) of contact (POC) or appointed ad hoc. \nAreas where hazardous drug handling occurs will be tested by Environmental Wipe Sampling for Hazardous Drug (HD) Residue:\nEvery 6 months, or more frequently as needed to verify contaminant, environmental wipe sampling for HD residue will be performed by an appointed trained Northport VAMC personnel. The collected samples will be shipped to the contractor s laboratory service for HD residue analysis.  The kits used to complete HD wipe sampling must be verified prior to use to ensure the sensitivity and validity of the methods and reagents used to recover a specific percentage of known marker drugs.\nThe hazardous drugs (HDs) to be tested will be determined by the facility and may include, but are not limited to:\nCyclophosphamide\nIfosfamide\nFluorouracil\nGemcitabine\nMethotrexate\nPlatinum-containing drugs\nTaxane-based drugs\nOn average 14 surface environmental HD wipe samples will be collected per testing date. The facility can elect to adjust the quantities of samples submitted as needed during investigative remediation. Routine environmental HD wipe sampling will include, at minimum, the following areas:\nInterior of containment primary engineering control (C-PEC) and any equipment contained inside the C-PEC.\nPass-through chambers.\nSurfaces in staging or work areas near C-PEC.\nAreas adjacent to C-PECs (e.g., floors directly under C-PEC, staging, and dispensing area).\nAreas immediately outside the hazardous drug buffer room or C-SCA.\nAreas designated for pharmacist end product verification (checking) / workstations.\nHazardous drug storage areas (including refrigerators).\nHazardous drug receiving areas.\nPatient administration areas.\n\nCompetency of Technician Performing Testing\nCETA testing must be performed by a CNBT individual/company accredited to perform this work. The technician/contractor shall provide a copy of the individuals CETA credentials at time of offer. If, during the contract, a different individual(s) is designated by the contractor, the CETA certification credentials of the assigned individual(s) must be provided to the POC, CO, and COR prior to the start of work.\nTo ensure accurate and reproducible sampling results, environmental viable sampling should be performed by a CETA CNBT technician or a trained technician competent in air and surface sampling procedures. Prior to sampling the contractor must provide  the facility documentation records for the individuals training and competencies to perform sampling.\n\nAdditional Contracting Requirements\nCertification periodicities shall be confirmed by contractor, post award, and adjusted as necessary to meet the needs of the Northport VAMC. \nCertification and testing shall conform to USP and OSHA standards.\nTechnician will disinfect and sanitize all equipment brought into the cleanroom suite or segregated compounding area prior to entry (with PreEmptÂ® or PeridoxÂ® (or facility approved disinfectant cleaner), followed by sterile 70% isopropyl alcohol or as per current standard operating procedure for the cleanroom suite).\nContractor will follow Northport VAMC s protocols for use of PPE in the classified spaces and understands the risks associated with facilities and equipment designed for storage and preparation of hazardous drugs.\nThe contractor shall comply with Federal, State, and Local Laws, plus and federal regulations as applicable to the performance of this contract; to include USP Chapter 797 and USP Chapter 800. Contractor must obtain all necessary licenses and/or permits required to perform the work herein.\n\nReporting Results for CETA Testing (including Viable Sampling)\nA  General Report Documentation  for all CETA test results must be provided via email directly to the COR (Contracting Officer Representative), Chief of Facility Management Services, Chief of Pharmacy Service, and to the Designated Compounding Pharmacist no later than one week after the testing is performed. The CETA report will be a comprehensive informative report of the certification process which will include a statement of compliance or non-compliance regarding the requirements and guidelines outlined respective to CETA Application Guide.  The formal report will include as a minimum, but not limited to, the following items:\nName, address, and contact information for the certifying organization also listing key personnel with appropriate accreditations including the name of CETA-certified technician performing the testing.\nConfirming remark that facility/equipment was tested  in accordance with CETA CAG-003:2022 (or most current version) and any other applicable performance testing standard followed. The most current version of this CAG must be referenced. Note: USP 797 is not a certification specification.  \nExplanation of test procedure used for data collection and justification for any deviations from established industry practices encountered during the certification process.  \nA list of test equipment utilized in data collection. List shall include make, model, serial number, and calibration date. A copy of the current calibration documentation for each piece of equipment must be provided when requested.\nRequired reporting values listed in each test section \nType, make, model and serial number for each PEC tested\nEach PEC and SEC nonviable particulate counts (including sample volume and time) and ISO classification\nMeasured air velocity data for PEC, including air flow in CFM, average and standard deviation of air velocity measurements and acceptance criteria\nPEC blower setting and pressure gauge reading (if any)\nFor BSCs: \nmeasured downflow air velocity data, acceptance criteria and pass/fail result\nmeasured exhaust damper acceptance criteria and pass/fail result\ninflow velocity test method, measurements, and results\nDocumentation of results for the video of the airflow smoke pattern test documenting unidirectional flow at critical sites in the PEC.\nTotal Air Changes Per Hour (ACPH) for each SEC, with indication of ACPH supplied by the PECs\nPressure differentials between each SEC and the anteroom/pharmacy\nResults of HEPA leak tests for all filters tested, as well as the results of any patching that was performed\nIf leaks were detected and sealed, include a diagram showing approximate location of sealed leaks\nPrefilter type, size, and condition for each PEC\nSEC temperature and relative humidity\nVideo recording of all smoke pattern testing (airflow and dynamic)\nAlarm test results (if any)\nA diagram of the areas tested, noting the approximate location of air and surface particle counts\nAny recommendations for HEPA replacement/HEPA lifespan\n\nMicrobiological lab analysis reports must meet the following:\nThe laboratory performing microbial analysis must be an American Association for Laboratory Accreditation (A2LA)-accredited laboratory with ISO/IEC 17025 certification for microbiological testing.\nAll viable and non-viable analyzed sampling results must be provided via email directly to the Chief of Facility Management Services, Chief of Pharmacy Service, and to the Designated Compounding Pharmacist no later than 2 weeks after sampling is performed. At a minimum, the provided lab analysis report must include:\nThe manufacturer, lot number, and expiration date for each media lot analyzed.\nDate and time sampling was performed.\nComments indicating sampling under dynamic conditions.\nSampling location(s), with a Site Map sketch identifying location of each sample obtained.\nSampling type and incubation dates, temperature, and duration intervals.\nQuantitative number of discrete colonies of microorganisms on each media device as colony forming units (CFUs) of bacterial/fungal isolates. Results equal to or greater than the action level will require immediate notification to the facility s the POC(s).\nRecovered organisms identified to the genus level (The pharmacy must be notified of any microbial growth immediately after it is identified (no later than 48 hours after the report is received by the contractor from the laboratory). \nDetermination of whether lab findings are actionable (e.g., acceptable/unacceptable as per USP 797).\n\nResponse-Travel- Expense Considerations\nResponse Time- The Contractor shall use commercially reasonable efforts to:\nProvide technical support via telephone to Northport VAMC on a 24/7, 365 days a year schedule.\nRespond by telephone to any report of a malfunction requiring repair within one hour of notification.\nProvide on-site support within 2 hours of notification unless prevented by unforeseen circumstances.\nTravel Time\nDue to the time sensitive nature of testing, the contractor must guarantee a maximum two-hour time travel and arrival at facility on scheduled testing dates for any required testing personnel and equipment.\nTravel Expenses-\nContractor shall be responsible for all service-related equipment shipping and tester s trip expenses, including but not limited to round trip travel, mileage, meals, and overnight living expenses.\n\nTitle to Equipment- Contractor shall not assume possession or control of any part of the equipment. The Government retains ownership to title thereof.\n\nUtilities- Contractor may use Government utilities, (e.g., electrical power, compressed air, and water) which are available and required for any service performed under this contract.\n\nAccess to Equipment- Contractor shall be provided reasonable access to all equipment that is to be serviced and utility outlets required to do the service. The contractor shall be free to start and stop all primary equipment incidentals to the operation of the maintained equipment after permission is received from on duty personnel responsible for such equipment.\n\nParts and Materials- All compensation for parts and materials is included in contract price.\n\nParts/Supplies Quality- Parts and Supplies provided under this contract shall be new OEM (Original Equipment Manufacturer) parts.\n\nField Service Reports- Contractor shall furnish a written or electronic vendor supplied Field Service Report (FSR).\n\nPlace of Performance. \nNorthport VAMC\n79 Middleville Road\nNorthport, N.Y. 11768\n\nPeriod of Performance.\nBase plus four (4) option years\n\n\nInformation Security/Privacy/ Records Management\nThis contract does not involve access to VA patient/employee information and does not involve access and/or connection to the VA information system.\n\nVA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or the Use of VA Sensitive Information\n\nThe Department of Veterans Affairs, VA must comply with all applicable privacy and confidentiality statutes and regulations. One of the requirements in VA is to have all personnel trained annually on privacy requirements.  Privacy  represents what must be protected by VA in the collection, use, and disclosure of personal information whether the medium is electronic, paper or verbal.\nThis document (20939 training) satisfies the  basic  privacy training requirement for a contractor, volunteer, or other personnel only if the individual does not use VA sensitive information or protected health information (PHI) in any form such as electronic or paper or have access to any VA computer system.\nThe Contracting Officer Representative (COR/ COTR/ Project Manager) is responsible to obtain this training from the contractor and to maintain according to the Records Control Schedule (RCS 10-1).","text":"The Department of Veterans Affairs Network Contracting Office 2 is issuing this source sought synopsis as a means of conducting market research to identify parties having an interest in and the resources providing Testing of Sterile Compounding Areas at the Northport VAMC, 79 Middleville Road , Northport, NY 11768.\nThe result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 541380.\nThe VA requires a 12-month base year, plus four 12-month options contract. This contract will be inclusive of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION.\nTelephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above listed services are invited to submit a response to this Sources Sought Notice by October 24, 2024, at 12:00PM EST. All responses under this Sources Sought Notice must be emailed to Lee.Kern@va.gov.\nPlease see the below Statement of Work (SOW):\nSTATEMENT OF WORK\nTesting of Sterile Compounding Areas\n\nINTRODUCTION\nUnited States Pharmacopeia (USP) establishes standards for cleanroom design, environmental monitoring, and competencies for the preparation, handling, and storage of compounded sterile preparations (CSPs). To maintain compliance with these standards, Northport VAMC requires a Base plus four (4) year contract inclusive of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas. Certification and testing will consist of:\ntesting all primary engineering controls [(PECs) e.g., biological safety cabinets (BSCs), laminar airflow workbenches (LAFWs), compounding aseptic containment isolators (CACI), and compounding aseptic isolators (CAI)]\ntesting all secondary engineering controls (SECs), non-ISO rated controlled non-classified (CNC) rooms, and High-efficiency particulate air (HEPA) filtration devices.\nmicrobiological laboratory testing of collected viables samples.\nwipe sampling for environmental Hazardous Drug (HD) residue\n\nTesting and certification must be completed in accordance with the most currently published versions of USP Chapter , USP Chapter , Controlled Environment Testing Association (CETA) Application Guides for: CAG-003 Certification of Sterile Compounding Facilities for USP Compliance, CAG-002 Compounding Isolator Testing, CAG-008 Certification Matrix for\nSterile & Nonsterile USP Compounding Facilities, CAG-009 Viable Environmental Monitoring for Sterile Compounding Facilities, CAG-014 Airflow Visualization Study, National Sanitation Foundation/American National Standards Institute (NSF/ANSI) Standard 49 Biosafety Cabinetry, and Institute of Flow Clean Air Devices, IEST-RP-CC-002.4. All lab analysis of viable samples must be performed by a facility with ISO/IEC 17025 accreditation for microbial analysis. This environmental quality testing may not be performed under the laboratory s Clinical Laboratory Improvement Amendments (CLIA) license. The lab must attain ISO/IEC 17025 certification from an external accrediting body (e.g., American Association for Laboratory Accreditation ) to ensure quality and accuracy of the testing.\n\nBACKGROUND.\nNorthport VAMC is pursuing a facility contract for certification of all PECs, SECs, CNC rooms, and HEPA filters must be performed pursuant to the most current version of USP Chapter and USP Chapter standards following CETA s standardized testing procedures which include (but is not limited to) CAG-003 CETA Certification Guide for Sterile Compounding Facilities for USP Compliance, CAG-002 CETA Compounding Isolator Testing Guide, CAG-014 Airflow Visualization Study, and CAG-009 Viable Environmental Monitoring for Sterile Compounding Facilities.\n\nCertification must be performed every 6 months. Recertification will be required after any servicing of facilities or equipment, post changes to the area that could affect airflow or air quality ( e.g., redesign, construction, replacement or relocation of any PEC, or alteration in the configuration of the room), and/or in response to identified problems or trends.\n\nCertification procedures defined in relevant CETA Application Guides must be performed no less than every 6 months by an individual who has the required CETA competencies and training related to the certification of primary and secondary engineering controls. Additionally, it is preferred that the on-site certification individual have received NSF accreditation for the field certification of Class II Biosafety Cabinets and are accredited through CNBT as a registered certification professional in the sterile compounding facility (RCP-SCF). Prior to testing, the contractor s technician(s) who conduct on-site certification will provide, to the COR, documentation of competency and training related to the certification of PECs and SECs.\n\nProcedures for air and surface sampling and evaluation must be compliant as per the most current USP Chapter 797 requirements for environmental air sampling, surface sampling (CAG-009), gloved fingertip testing (CAG-011), and media fill testing (CAG-013) following the appropriate CETA CAG application guide.\n\nNorthport VAMC s sterile compounding areas and equipment must be compliant to The Joint Commission (TJC) and Food and Drug Administration (FDA) requirements. TJC Medication Compounding Requirements for Critical Access Hospitals and Hospitals, effective January 1, 2024, established new Medication Compounding (MC) standards for non-sterile and sterile compounded preparations which are based on USP standards. The FDA has the authority to inspect VA medical facilities under the Food, Drug and Cosmetic Act, and evaluate based upon the guidance provided in the Insanitary Conditions at Compounding Facilities Guidance for Industry, November 2020 (or most current version).\n\nSCOPE\nTesting Frequency.\nThe Northport VAMC has a requirement for onsite initial and reoccurring CETA certification and viable environmental sampling of the facility s Pharmacy-specific and non-Pharmacy specific areas and equipment as detailed within this Statement of Work (SOW). Testing and certification dates contained within this SOW are best documented; Contractor shall be responsible to confirm and/or adjust certification/testing requirements to ensure no lapse in requirements and thus no undesirable effect on the mission of the Northport VAMC.\nAll pharmacy-specific equipment will minimally obtain CETA certification every six (6) calendar months from the date of the last certification/testing of BSCs, LAFWs, CAI, CACI, HEPA filters, and room spaces/environments in accordance with VHA Directive 1108.12 (see attachment A), and USP 797 (Attachment B) & 800 (Attachment C). Recertification may be required sooner if equipment is relocated/altered, or a major service is performed.\n\nTesting Locations. The following location shall be tested as per USP 797 and where applicable USP 800 standards as per respective CETA guide applications. Locations may be amended as per the facility s renovations and construction.\nBuilding 200, Unit 31 Cleanroom suite(s) Primary Space(s) and equipment\nISO-8 Anteroom(s): Two ceiling mounted HEPA filters\nISO-7 Buffer room(s)\nTwo ceiling mounted HEPA filters\nOne ISO-5 LAWF: Baker Edgegard 5252 LAWF\nBuilding 200, Inpatient: One ISO-5 Compounding Aseptic Isolator (CAI): Baker SS-500\nBuilding 200, New pavilion 2F, E2-49\nHD negative pressure storage room: One ceiling mounted HEPA filter\nCNC HD negative pressure C-SCA\nOne ceiling mounted HEPA filter\nOne ISO-5 HD negative pressure Compounding Aseptic Containment Isolator (CACI): Baker CS-500\nGermFree Trailer (adjacent to building 11) - This location will be covered under this contract for monthly viable sampling and hazardous drug wipe sampling.\nNote: There is a separate contract which covers the semiannual CETA testing and viable sampling of the trailer.\n\nTesting Requirements of PECs.\nBiological safety cabinet (BSC): On-site certifications of the BSCs shall be tested to manufacturer specifications in accordance with the most recent version of NSF/ANSI Standard 49 Biosafety Cabinetry (as per CETA CAG-003:2022 section 8.2. through 8.2.5 application guide and CETA CAG-005:2007 (or most current versions)\nCompounding Aseptic Isolator (CAI) and Compounding Aseptic Containment Isolator (CACI): The contractor shall test and certify all CAIs and CACIs as per CETA CAG-003 sections 8.3 through 8.3.5 and in accordance with CETA CAG-002 guide application.\nLaminar Air Flow Workbench (LAFW): The contractor shall test and certify all LAFW as per CETA CAG-003:2022 section 8.4. through 8.4.6 application guide (or most current version)\nThe contractor shall test and certify all PECs in accordance with the most current version of The Institute of Environmental Sciences and Technology (IEST)-RP-CC002 (Unidirectional Flow Clean-Air Devices), CETA CAG-003, and the manufacturer's specifications.\nThe contractor shall record each individual face velocity reading and the average of those readings, the downstream concentration reading of the HEPA filter leak test and the results of the induction leak test and back streaming test\nAll equipment used to certify PECs must be calibrated in accordance with IEST-RP-CC013 or manufacturer's recommendation and be NIST traceable where possible.\nWhere applicable the list of tests for PECs includes, where applicable but not limited to the following:\nAir flow velocity profile\nAir flow visualization profile: dynamic smoke pattern testing (video recorded and provided to us on a thumb drive or made available for download on a secure website) for all primary engineering controls. Tester must utilize sufficient smoke to demonstrate unidirectional airflow at critical sites and sweeping action over and away from preparations.\nPrefilter check\nHEPA/ULPA filter leak integrity testing (must be performed upon installation and as part of certification)\nInduction leak integrity test and patching if necessary\nElectrical leakage and ground circuit resistance and polarity tests\nPreparation ingress and egress test where applicable\nChamber pressure test\nTotal airborne non-viable particle count testing in all classified areas performed under dynamic operating conditions\nFor each PEC passing the required certification tests, the contractor supplies each unit with a certification tag or sticker displaying the following information:\nCompany name and contact information.\nUnit make, model and serial number.\nReport number\nLocation (e.g., building, room number, area identification)\nCertification date\nRecertification date\nTechnician name and signature\nAny PEC that fails to meet CETA specifications shall be clearly marked with signage which alerts compounding personnel that the unit is out of order until further notice.\n\nTesting Requirements of SECs.\nThe contractor will provide comprehensive cleanroom testing and certification services every 6 months, in the event of an environmental or engineering control excursion/exceedance or sooner if there are changes to the area such as redesign, construction, replacement or relocation of any PEC, or alteration in the configuration of the room that could affect airflow or air quality or if a cleanroom(s) did not meet compliance. Certification tests for rooms within a cleanroom suite include, but are not limited to:\nAirflow testing: HEPA filter(s) air volumes and velocities will be measured and documented as per CETA CAG-003:2022 section 8.1.1 application guide (or most current version)\nAirflow testing is performed to determine acceptability of the air velocity, the room air exchange rate, and the room pressure differential in doorways between adjacent rooms to ensure consistent airflow and that the appropriate quality of air is maintained under dynamic operating conditions.\nThe contractor shall calculate the total room area and volume for each buffer room, anteroom, Containment segregated compounding area (C-SCA), and hazardous drug storage room. The ISO classification and a sketch of the room with dimensions, exhaust/supply diffuser locations and equipment locations shall be included in the report. The report provided will specify flow rates detailing returns and supply that were obtained during the testing. The contractor shall calculate air changes per hour (ACPH) for each buffer and anteroom and include their findings in the report. ACPH for HVAC, ACPH contributed from PEC, and the total ACPH. Comparison of ACPH will be completed both for USP 797 standards as well as those referenced in the VHA HVAC Design Manual (Attachment D or earlier version if available), which are further stringent than USP Chapter 797.\nISO Classified Turbulent Airflow Area Reporting and Documentation\nRecord all airflow measurements and their corresponding filter or diffuser locations or grid identifications on a diagram\nCalculate and report room volume\nCalculate and report the average total room airflow volume\nCalculate and report the total air changes per hour of the room (include LAFW and/or Non-ducted BSC HEPA exhaust to room, where applicable)\nReport any correction factors used or deviations from the primary method\nName of test (e.g., Room Airflow Analysis)\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nNon-ISO Classified Negative Pressure Turbulent Airflow Area Testing Procedure including ACPH requirements for containment segregated compounding areas and hazardous drug storage areas, must be a minimum of 12 exhaust ACPH. Because these rooms/areas are not ISO classified airflow measurements should be taken on the exhaust of negative pressure differential rooms. Non-ISO Classified Negative Pressure Turbulent Airflow Reporting and Documentation must include:\nRecord all airflow measurements and their corresponding exhaust filter or exhaust grill locations\nCalculate and report room volume\nCalculate and report the average total room airflow volume\nCalculate and report the total air changes per hour of the room\nReport any correction factors used or deviations from the primary method\nName of test (e.g., Unclassified Negative Pressure Room Airflow Analysis)\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nSEC HEPA filter integrity testing performed as per CETA CAG-003:2022 section 8.1.2 application guide (or most current version)\nRecord upstream aerosol challenge concentration\nList method used to report concentration (measured or calculated)\nRecord maximum leak penetration in percent\nName of test (HEPA Filter Leak Test)\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nSEC Room Pressure Differential/Room Pressurization as per CETA CAG-003:2022 section 8.1.3 application guide (or most current version)\nThe contractor shall include in their report differential pressure readings from each buffer room, anteroom, C-SCA, and Hazardous Drug (HD) storage rooms to all surrounding areas.\nThe report shall indicate whether the area is required to be a negative or positive pressure location as per USP 797 and/or USP 800. All readings and acceptance criteria shall be documented to at least one thousandths of an inch water gauge or water column (e.g., 0.020 w.g. and not 0.02 w.g.) or one tenth of a pascal (e.g., 5.0 Pa). Pressure differentials will be reflected on a report showing the sketch of the room(s).\nSEC Room Pressure Reporting and Documentation\nReport room pressure differential relative to an adjacent room/space\nReport and compare performance of room pressure monitor\nReport whether smoke dispersed at entry doors follows correct direction\nName of test (Room Pressure Differential Test)\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nTotal airborne particle count testing (0.5 micron and larger) in all classified areas performed under dynamic operating conditions as per CETA CAG-003:2022 section 8.1.5 application guide (or most current version). Reporting shall be completed following ISO 14644-01 [2015] section 5.4 Test report and shall include the following:\nThe name and address of the testing organization, and the date on which the test was performed\nThe number and year of publication of this part of ISO 14644 (i.e., ISO 14644 1:2015)\nA clear identification of the physical location of the cleanroom or clean zone testing (including reference to adjacent areas if necessary), and specific designations for coordinates of all sampling locations (a diagrammatic representation can be helpful)\nThe specified designation criteria for the cleanroom or clean zone, including the ISO Class number, the relevant occupancy state(s), and the considered particle size(s)\nDetails of the test method used, with any special conditions relating to the test, or departures from the test method, and identification of the test instrument and its current calibration certificate\nThe test results, including particle concentration data for all sampling locations\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nSEC Airflow Visualization Studies (AVS) - Visual Smoke Studies per CETA CAG-014 guide application\nSEC General Temperature and Moisture Tests to verify accuracy of monitoring devices as per CETA CAG-003:2022 section 8.1.7 application guide (or most current version)\nSEC Viable Sampling as per CETA CAG-003:2022 section 8.1.6 and CAG-009:2020 application guides\n\nViable Sampling Testing All viable sampling will conform to USP 797 requirements and performed as per CETA CAG-009 application guide Viable Environmental Monitoring for Sterile Compounding Facilities\nEnvironmental Air Sampling.\nBiannually (every six months) the collection of environmental air samples will be performed by the contractor s CETA technician during certification and during negatively impactful incidents which require repeat air sampling as follows:\nwhenever there is a change to the placement of equipment in the room or any other alteration within the cleanroom suite that affects the quality of the air.\nin response to identified problems and trends.\nin response to changes that could impact the sterile environment (changes in cleaning agents).\nViable air sampling will be performed utilizing a calibrated high-volume impaction sampler during dynamic operating conditions\nSingle plate TSA media which supports growth of both bacteria and fungi will be used to sample. A sufficient volume of air (1000 liters) shall be tested at each location to maximize sensitivity (samples of less than 1000 liters will not be acceptable)\nPositive and negative control plates will be included with sampled plates submitted by the contractor for analysis.\nEnvironmental Surface Sampling.\nBiannually (every six months) the collection of environmental surface samples will be performed by the contractor s CETA technician and during repeated CETA testing. Upon the request of the facility, the contractor will repeat surface sampling as follows:\nwhenever, there is a change to the placement of equipment in the room or any other alteration within the cleanroom suite that affects the quality of the air.\nin response to identified problems and trends.\nin response to changes that could impact the sterile environment (changes in cleaning agents).\nSurface samples will be collected in each room, the interior of each PEC, passthrough chambers connecting to classified areas, and frequently touched surfaces (e.g., door, tables, carts, stools, benches, etc.)\nSurface sampling will be performed at the end of the largest CSP activity of the day but before area has been cleaned and disinfected.\nSingle plate TSA media supplemented with neutralizing additives (e.g., lecithin and polysorbate 80) to neutralize the effects of any residual disinfecting agents will be used.\nRoutine monthly surface sampling will be performed by an appointed trained Northport VAMC personnel. The collected samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis.\nAs needed, appointed trained Northport VAMC personnel will collect surface samples within the PEC as a part of the competency assessment for assigned personnel. The collected samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis.\nPersonnel Viable Sampling.\nThe collection of personnel viable samples for competency testing will be performed by an appointed trained Northport VAMC personnel. The samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis when it is required for personnel competency assessment sampling as follows:\nGloved Fingertip and Thumb (GFT) Testing\nUpon initial assignment compounding staff will be assessed, post hand hygiene and garbing, utilizing GFT samples in triplicate (three samples/hand) for analysis.\nEvery six (6) months and thereafter compounding staff will be assessed, post hand hygiene and garbing, utilizing single collection of GFT samples (one sample/hand) will be collected for analysis post hand hygiene and garbing.\nInitially and every six (6) months thereafter compounding staff will be assessed for GFT during aseptic manipulations, utilizing single collection of GFT samples (one sample/hand) post media fill testing (MFT).\nMedia Fill Test (MFT)\nUpon initial assignment and every six months thereafter, compounding staff will be assessed for aseptic manipulations utilizing USP 797 compliant media fill testing kits.\nOther Viable Sampling Requirements.\nThe laboratory service employed by the contractor must be able to provide the following:\nMicrobial growth media plates which are USP 797 compliant and\ninclude certificates of analysis (COA) from the manufacturer that verify the plates meet the expected growth promotion, pH, and sterilization requirements consistent with USP Chapter 797\ncontain TSA supplemented with neutralizing additives (lecithin and polysorbate 80)\nhave a raised convex surface\nsupport both bacterial and fungal growth on the same plate for single media incubation\nMedia fill testing (MFT) kits compliant to USP 797 and designed to\nsimulate medium complexity (Category 2) sterile IV compounding.\nsimulate low complexity (Category 1) sterile IV compounding.\nA chain of custody documenting each sample collected must be created and provided to the Northport VAMC .\nDuring self-sampling, which is performed by Northport VAMC, the contracted lab is responsible for providing a prepaid mailer for properly sending samples to the laboratory for testing.\nAll samples shipped to the laboratory service must be incubated in accordance with current USP Chapter 797 requirements for duration and temperature.\nAdditional Requirements for PECs and/or SECs Testing\nAny PEC or SEC that fails to meet CETA specifications shall be immediately reported directly to the site-identified point(s) of contact (POC) or appointed ad hoc.\nAreas where hazardous drug handling occurs will be tested by Environmental Wipe Sampling for Hazardous Drug (HD) Residue:\nEvery 6 months, or more frequently as needed to verify contaminant, environmental wipe sampling for HD residue will be performed by an appointed trained Northport VAMC personnel. The collected samples will be shipped to the contractor s laboratory service for HD residue analysis. The kits used to complete HD wipe sampling must be verified prior to use to ensure the sensitivity and validity of the methods and reagents used to recover a specific percentage of known marker drugs.\nThe hazardous drugs (HDs) to be tested will be determined by the facility and may include, but are not limited to:\nCyclophosphamide\nIfosfamide\nFluorouracil\nGemcitabine\nMethotrexate\nPlatinum-containing drugs\nTaxane-based drugs\nOn average 14 surface environmental HD wipe samples will be collected per testing date. The facility can elect to adjust the quantities of samples submitted as needed during investigative remediation. Routine environmental HD wipe sampling will include, at minimum, the following areas:\nInterior of containment primary engineering control (C-PEC) and any equipment contained inside the C-PEC.\nPass-through chambers.\nSurfaces in staging or work areas near C-PEC.\nAreas adjacent to C-PECs (e.g., floors directly under C-PEC, staging, and dispensing area).\nAreas immediately outside the hazardous drug buffer room or C-SCA.\nAreas designated for pharmacist end product verification (checking) / workstations.\nHazardous drug storage areas (including refrigerators).\nHazardous drug receiving areas.\nPatient administration areas.\n\nCompetency of Technician Performing Testing\nCETA testing must be performed by a CNBT individual/company accredited to perform this work. The technician/contractor shall provide a copy of the individuals CETA credentials at time of offer. If, during the contract, a different individual(s) is designated by the contractor, the CETA certification credentials of the assigned individual(s) must be provided to the POC, CO, and COR prior to the start of work.\nTo ensure accurate and reproducible sampling results, environmental viable sampling should be performed by a CETA CNBT technician or a trained technician competent in air and surface sampling procedures. Prior to sampling the contractor must provide the facility documentation records for the individuals training and competencies to perform sampling.\n\nAdditional Contracting Requirements\nCertification periodicities shall be confirmed by contractor, post award, and adjusted as necessary to meet the needs of the Northport VAMC.\nCertification and testing shall conform to USP and OSHA standards.\nTechnician will disinfect and sanitize all equipment brought into the cleanroom suite or segregated compounding area prior to entry (with PreEmptÂ® or PeridoxÂ® (or facility approved disinfectant cleaner), followed by sterile 70% isopropyl alcohol or as per current standard operating procedure for the cleanroom suite).\nContractor will follow Northport VAMC s protocols for use of PPE in the classified spaces and understands the risks associated with facilities and equipment designed for storage and preparation of hazardous drugs.\nThe contractor shall comply with Federal, State, and Local Laws, plus and federal regulations as applicable to the performance of this contract; to include USP Chapter 797 and USP Chapter 800. Contractor must obtain all necessary licenses and/or permits required to perform the work herein.\n\nReporting Results for CETA Testing (including Viable Sampling)\nA General Report Documentation for all CETA test results must be provided via email directly to the COR (Contracting Officer Representative), Chief of Facility Management Services, Chief of Pharmacy Service, and to the Designated Compounding Pharmacist no later than one week after the testing is performed. The CETA report will be a comprehensive informative report of the certification process which will include a statement of compliance or non-compliance regarding the requirements and guidelines outlined respective to CETA Application Guide. The formal report will include as a minimum, but not limited to, the following items:\nName, address, and contact information for the certifying organization also listing key personnel with appropriate accreditations including the name of CETA-certified technician performing the testing.\nConfirming remark that facility/equipment was tested in accordance with CETA CAG-003:2022 (or most current version) and any other applicable performance testing standard followed. The most current version of this CAG must be referenced. Note: USP 797 is not a certification specification.\nExplanation of test procedure used for data collection and justification for any deviations from established industry practices encountered during the certification process.\nA list of test equipment utilized in data collection. List shall include make, model, serial number, and calibration date. A copy of the current calibration documentation for each piece of equipment must be provided when requested.\nRequired reporting values listed in each test section\nType, make, model and serial number for each PEC tested\nEach PEC and SEC nonviable particulate counts (including sample volume and time) and ISO classification\nMeasured air velocity data for PEC, including air flow in CFM, average and standard deviation of air velocity measurements and acceptance criteria\nPEC blower setting and pressure gauge reading (if any)\nFor BSCs:\nmeasured downflow air velocity data, acceptance criteria and pass/fail result\nmeasured exhaust damper acceptance criteria and pass/fail result\ninflow velocity test method, measurements, and results\nDocumentation of results for the video of the airflow smoke pattern test documenting unidirectional flow at critical sites in the PEC.\nTotal Air Changes Per Hour (ACPH) for each SEC, with indication of ACPH supplied by the PECs\nPressure differentials between each SEC and the anteroom/pharmacy\nResults of HEPA leak tests for all filters tested, as well as the results of any patching that was performed\nIf leaks were detected and sealed, include a diagram showing approximate location of sealed leaks\nPrefilter type, size, and condition for each PEC\nSEC temperature and relative humidity\nVideo recording of all smoke pattern testing (airflow and dynamic)\nAlarm test results (if any)\nA diagram of the areas tested, noting the approximate location of air and surface particle counts\nAny recommendations for HEPA replacement/HEPA lifespan\n\nMicrobiological lab analysis reports must meet the following:\nThe laboratory performing microbial analysis must be an American Association for Laboratory Accreditation (A2LA)-accredited laboratory with ISO/IEC 17025 certification for microbiological testing.\nAll viable and non-viable analyzed sampling results must be provided via email directly to the Chief of Facility Management Services, Chief of Pharmacy Service, and to the Designated Compounding Pharmacist no later than 2 weeks after sampling is performed. At a minimum, the provided lab analysis report must include:\nThe manufacturer, lot number, and expiration date for each media lot analyzed.\nDate and time sampling was performed.\nComments indicating sampling under dynamic conditions.\nSampling location(s), with a Site Map sketch identifying location of each sample obtained.\nSampling type and incubation dates, temperature, and duration intervals.\nQuantitative number of discrete colonies of microorganisms on each media device as colony forming units (CFUs) of bacterial/fungal isolates. Results equal to or greater than the action level will require immediate notification to the facility s the POC(s).\nRecovered organisms identified to the genus level (The pharmacy must be notified of any microbial growth immediately after it is identified (no later than 48 hours after the report is received by the contractor from the laboratory).\nDetermination of whether lab findings are actionable (e.g., acceptable/unacceptable as per USP 797).\n\nResponse-Travel- Expense Considerations\nResponse Time- The Contractor shall use commercially reasonable efforts to:\nProvide technical support via telephone to Northport VAMC on a 24/7, 365 days a year schedule.\nRespond by telephone to any report of a malfunction requiring repair within one hour of notification.\nProvide on-site support within 2 hours of notification unless prevented by unforeseen circumstances.\nTravel Time\nDue to the time sensitive nature of testing, the contractor must guarantee a maximum two-hour time travel and arrival at facility on scheduled testing dates for any required testing personnel and equipment.\nTravel Expenses-\nContractor shall be responsible for all service-related equipment shipping and tester s trip expenses, including but not limited to round trip travel, mileage, meals, and overnight living expenses.\n\nTitle to Equipment- Contractor shall not assume possession or control of any part of the equipment. The Government retains ownership to title thereof.\n\nUtilities- Contractor may use Government utilities, (e.g., electrical power, compressed air, and water) which are available and required for any service performed under this contract.\n\nAccess to Equipment- Contractor shall be provided reasonable access to all equipment that is to be serviced and utility outlets required to do the service. The contractor shall be free to start and stop all primary equipment incidentals to the operation of the maintained equipment after permission is received from on duty personnel responsible for such equipment.\n\nParts and Materials- All compensation for parts and materials is included in contract price.\n\nParts/Supplies Quality- Parts and Supplies provided under this contract shall be new OEM (Original Equipment Manufacturer) parts.\n\nField Service Reports- Contractor shall furnish a written or electronic vendor supplied Field Service Report (FSR).\n\nPlace of Performance.\nNorthport VAMC\n79 Middleville Road\nNorthport, N.Y. 11768\n\nPeriod of Performance.\nBase plus four (4) option years\n\nInformation Security/Privacy/ Records Management\nThis contract does not involve access to VA patient/employee information and does not involve access and/or connection to the VA information system.\n\nVA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or the Use of VA Sensitive Information\n\nThe Department of Veterans Affairs, VA must comply with all applicable privacy and confidentiality statutes and regulations. One of the requirements in VA is to have all personnel trained annually on privacy requirements. Privacy represents what must be protected by VA in the collection, use, and disclosure of personal information whether the medium is electronic, paper or verbal.\nThis document (20939 training) satisfies the basic privacy training requirement for a contractor, volunteer, or other personnel only if the individual does not use VA sensitive information or protected health information (PHI) in any form such as electronic or paper or have access to any VA computer system.\nThe Contracting Officer Representative (COR/ COTR/ Project Manager) is responsible to obtain this training from the contractor and to maintain according to the Records Control Schedule (RCS 10-1).","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"36C24225Q0222","place_of_performance":{"zip":"11768","city":{"name":"Northport"},"state":{"code":"NY","name":"New York"},"street":"Department of Veterans Affairs Northport VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"79 Middleville Road"},"product_service_code":"H266"}],"due_at":"2025-01-30T17:00:00Z","due_date":"2025-01-30","closes_at":"2025-01-30T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","state":"NY","county":"36103","county_name":"Suffolk County","city":"3653396","city_name":"Northport","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-24T10:25:06.068879Z","principal_notice_id":"5f3ef90d5211405bb53103ed61c6f774","description":{"text":"The Department of Veterans Affairs Network Contracting Office 2 is issuing this source sought synopsis as a means of conducting market research to identify parties having an interest in and the resources providing Testing of Sterile Compounding Areas at the Northport VAMC, 79 Middleville Road , Northport, NY 11768.\nThe result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 541380.\nThe VA requires a 12-month base year, plus four 12-month options contract. This contract will be inclusive of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION.\nTelephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above listed services are invited to submit a response to this Sources Sought Notice by October 24, 2024, at 12:00PM EST. All responses under this Sources Sought Notice must be emailed to Lee.Kern@va.gov.\nPlease see the below Statement of Work (SOW):\nSTATEMENT OF WORK\nTesting of Sterile Compounding Areas\n\nINTRODUCTION\nUnited States Pharmacopeia (USP) establishes standards for cleanroom design, environmental monitoring, and competencies for the preparation, handling, and storage of compounded sterile preparations (CSPs). To maintain compliance with these standards, Northport VAMC requires a Base plus four (4) year contract inclusive of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas. Certification and testing will consist of:\ntesting all primary engineering controls [(PECs) e.g., biological safety cabinets (BSCs), laminar airflow workbenches (LAFWs), compounding aseptic containment isolators (CACI), and compounding aseptic isolators (CAI)]\ntesting all secondary engineering controls (SECs), non-ISO rated controlled non-classified (CNC) rooms, and High-efficiency particulate air (HEPA) filtration devices.\nmicrobiological laboratory testing of collected viables samples.\nwipe sampling for environmental Hazardous Drug (HD) residue\n\nTesting and certification must be completed in accordance with the most currently published versions of USP Chapter , USP Chapter , Controlled Environment Testing Association (CETA) Application Guides for: CAG-003 Certification of Sterile Compounding Facilities for USP Compliance, CAG-002 Compounding Isolator Testing, CAG-008 Certification Matrix for\nSterile & Nonsterile USP Compounding Facilities, CAG-009 Viable Environmental Monitoring for Sterile Compounding Facilities, CAG-014 Airflow Visualization Study, National Sanitation Foundation/American National Standards Institute (NSF/ANSI) Standard 49 Biosafety Cabinetry, and Institute of Flow Clean Air Devices, IEST-RP-CC-002.4. All lab analysis of viable samples must be performed by a facility with ISO/IEC 17025 accreditation for microbial analysis. This environmental quality testing may not be performed under the laboratory s Clinical Laboratory Improvement Amendments (CLIA) license. The lab must attain ISO/IEC 17025 certification from an external accrediting body (e.g., American Association for Laboratory Accreditation ) to ensure quality and accuracy of the testing.\n\nBACKGROUND.\nNorthport VAMC is pursuing a facility contract for certification of all PECs, SECs, CNC rooms, and HEPA filters must be performed pursuant to the most current version of USP Chapter and USP Chapter standards following CETA s standardized testing procedures which include (but is not limited to) CAG-003 CETA Certification Guide for Sterile Compounding Facilities for USP Compliance, CAG-002 CETA Compounding Isolator Testing Guide, CAG-014 Airflow Visualization Study, and CAG-009 Viable Environmental Monitoring for Sterile Compounding Facilities.\n\nCertification must be performed every 6 months. Recertification will be required after any servicing of facilities or equipment, post changes to the area that could affect airflow or air quality ( e.g., redesign, construction, replacement or relocation of any PEC, or alteration in the configuration of the room), and/or in response to identified problems or trends.\n\nCertification procedures defined in relevant CETA Application Guides must be performed no less than every 6 months by an individual who has the required CETA competencies and training related to the certification of primary and secondary engineering controls. Additionally, it is preferred that the on-site certification individual have received NSF accreditation for the field certification of Class II Biosafety Cabinets and are accredited through CNBT as a registered certification professional in the sterile compounding facility (RCP-SCF). Prior to testing, the contractor s technician(s) who conduct on-site certification will provide, to the COR, documentation of competency and training related to the certification of PECs and SECs.\n\nProcedures for air and surface sampling and evaluation must be compliant as per the most current USP Chapter 797 requirements for environmental air sampling, surface sampling (CAG-009), gloved fingertip testing (CAG-011), and media fill testing (CAG-013) following the appropriate CETA CAG application guide.\n\nNorthport VAMC s sterile compounding areas and equipment must be compliant to The Joint Commission (TJC) and Food and Drug Administration (FDA) requirements. TJC Medication Compounding Requirements for Critical Access Hospitals and Hospitals, effective January 1, 2024, established new Medication Compounding (MC) standards for non-sterile and sterile compounded preparations which are based on USP standards. The FDA has the authority to inspect VA medical facilities under the Food, Drug and Cosmetic Act, and evaluate based upon the guidance provided in the Insanitary Conditions at Compounding Facilities Guidance for Industry, November 2020 (or most current version).\n\nSCOPE\nTesting Frequency.\nThe Northport VAMC has a requirement for onsite initial and reoccurring CETA certification and viable environmental sampling of the facility s Pharmacy-specific and non-Pharmacy specific areas and equipment as detailed within this Statement of Work (SOW). Testing and certification dates contained within this SOW are best documented; Contractor shall be responsible to confirm and/or adjust certification/testing requirements to ensure no lapse in requirements and thus no undesirable effect on the mission of the Northport VAMC.\nAll pharmacy-specific equipment will minimally obtain CETA certification every six (6) calendar months from the date of the last certification/testing of BSCs, LAFWs, CAI, CACI, HEPA filters, and room spaces/environments in accordance with VHA Directive 1108.12 (see attachment A), and USP 797 (Attachment B) & 800 (Attachment C). Recertification may be required sooner if equipment is relocated/altered, or a major service is performed.\n\nTesting Locations. The following location shall be tested as per USP 797 and where applicable USP 800 standards as per respective CETA guide applications. Locations may be amended as per the facility s renovations and construction.\nBuilding 200, Unit 31 Cleanroom suite(s) Primary Space(s) and equipment\nISO-8 Anteroom(s): Two ceiling mounted HEPA filters\nISO-7 Buffer room(s)\nTwo ceiling mounted HEPA filters\nOne ISO-5 LAWF: Baker Edgegard 5252 LAWF\nBuilding 200, Inpatient: One ISO-5 Compounding Aseptic Isolator (CAI): Baker SS-500\nBuilding 200, New pavilion 2F, E2-49\nHD negative pressure storage room: One ceiling mounted HEPA filter\nCNC HD negative pressure C-SCA\nOne ceiling mounted HEPA filter\nOne ISO-5 HD negative pressure Compounding Aseptic Containment Isolator (CACI): Baker CS-500\nGermFree Trailer (adjacent to building 11) - This location will be covered under this contract for monthly viable sampling and hazardous drug wipe sampling.\nNote: There is a separate contract which covers the semiannual CETA testing and viable sampling of the trailer.\n\nTesting Requirements of PECs.\nBiological safety cabinet (BSC): On-site certifications of the BSCs shall be tested to manufacturer specifications in accordance with the most recent version of NSF/ANSI Standard 49 Biosafety Cabinetry (as per CETA CAG-003:2022 section 8.2. through 8.2.5 application guide and CETA CAG-005:2007 (or most current versions)\nCompounding Aseptic Isolator (CAI) and Compounding Aseptic Containment Isolator (CACI): The contractor shall test and certify all CAIs and CACIs as per CETA CAG-003 sections 8.3 through 8.3.5 and in accordance with CETA CAG-002 guide application.\nLaminar Air Flow Workbench (LAFW): The contractor shall test and certify all LAFW as per CETA CAG-003:2022 section 8.4. through 8.4.6 application guide (or most current version)\nThe contractor shall test and certify all PECs in accordance with the most current version of The Institute of Environmental Sciences and Technology (IEST)-RP-CC002 (Unidirectional Flow Clean-Air Devices), CETA CAG-003, and the manufacturer's specifications.\nThe contractor shall record each individual face velocity reading and the average of those readings, the downstream concentration reading of the HEPA filter leak test and the results of the induction leak test and back streaming test\nAll equipment used to certify PECs must be calibrated in accordance with IEST-RP-CC013 or manufacturer's recommendation and be NIST traceable where possible.\nWhere applicable the list of tests for PECs includes, where applicable but not limited to the following:\nAir flow velocity profile\nAir flow visualization profile: dynamic smoke pattern testing (video recorded and provided to us on a thumb drive or made available for download on a secure website) for all primary engineering controls. Tester must utilize sufficient smoke to demonstrate unidirectional airflow at critical sites and sweeping action over and away from preparations.\nPrefilter check\nHEPA/ULPA filter leak integrity testing (must be performed upon installation and as part of certification)\nInduction leak integrity test and patching if necessary\nElectrical leakage and ground circuit resistance and polarity tests\nPreparation ingress and egress test where applicable\nChamber pressure test\nTotal airborne non-viable particle count testing in all classified areas performed under dynamic operating conditions\nFor each PEC passing the required certification tests, the contractor supplies each unit with a certification tag or sticker displaying the following information:\nCompany name and contact information.\nUnit make, model and serial number.\nReport number\nLocation (e.g., building, room number, area identification)\nCertification date\nRecertification date\nTechnician name and signature\nAny PEC that fails to meet CETA specifications shall be clearly marked with signage which alerts compounding personnel that the unit is out of order until further notice.\n\nTesting Requirements of SECs.\nThe contractor will provide comprehensive cleanroom testing and certification services every 6 months, in the event of an environmental or engineering control excursion/exceedance or sooner if there are changes to the area such as redesign, construction, replacement or relocation of any PEC, or alteration in the configuration of the room that could affect airflow or air quality or if a cleanroom(s) did not meet compliance. Certification tests for rooms within a cleanroom suite include, but are not limited to:\nAirflow testing: HEPA filter(s) air volumes and velocities will be measured and documented as per CETA CAG-003:2022 section 8.1.1 application guide (or most current version)\nAirflow testing is performed to determine acceptability of the air velocity, the room air exchange rate, and the room pressure differential in doorways between adjacent rooms to ensure consistent airflow and that the appropriate quality of air is maintained under dynamic operating conditions.\nThe contractor shall calculate the total room area and volume for each buffer room, anteroom, Containment segregated compounding area (C-SCA), and hazardous drug storage room. The ISO classification and a sketch of the room with dimensions, exhaust/supply diffuser locations and equipment locations shall be included in the report. The report provided will specify flow rates detailing returns and supply that were obtained during the testing. The contractor shall calculate air changes per hour (ACPH) for each buffer and anteroom and include their findings in the report. ACPH for HVAC, ACPH contributed from PEC, and the total ACPH. Comparison of ACPH will be completed both for USP 797 standards as well as those referenced in the VHA HVAC Design Manual (Attachment D or earlier version if available), which are further stringent than USP Chapter 797.\nISO Classified Turbulent Airflow Area Reporting and Documentation\nRecord all airflow measurements and their corresponding filter or diffuser locations or grid identifications on a diagram\nCalculate and report room volume\nCalculate and report the average total room airflow volume\nCalculate and report the total air changes per hour of the room (include LAFW and/or Non-ducted BSC HEPA exhaust to room, where applicable)\nReport any correction factors used or deviations from the primary method\nName of test (e.g., Room Airflow Analysis)\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nNon-ISO Classified Negative Pressure Turbulent Airflow Area Testing Procedure including ACPH requirements for containment segregated compounding areas and hazardous drug storage areas, must be a minimum of 12 exhaust ACPH. Because these rooms/areas are not ISO classified airflow measurements should be taken on the exhaust of negative pressure differential rooms. Non-ISO Classified Negative Pressure Turbulent Airflow Reporting and Documentation must include:\nRecord all airflow measurements and their corresponding exhaust filter or exhaust grill locations\nCalculate and report room volume\nCalculate and report the average total room airflow volume\nCalculate and report the total air changes per hour of the room\nReport any correction factors used or deviations from the primary method\nName of test (e.g., Unclassified Negative Pressure Room Airflow Analysis)\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nSEC HEPA filter integrity testing performed as per CETA CAG-003:2022 section 8.1.2 application guide (or most current version)\nRecord upstream aerosol challenge concentration\nList method used to report concentration (measured or calculated)\nRecord maximum leak penetration in percent\nName of test (HEPA Filter Leak Test)\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nSEC Room Pressure Differential/Room Pressurization as per CETA CAG-003:2022 section 8.1.3 application guide (or most current version)\nThe contractor shall include in their report differential pressure readings from each buffer room, anteroom, C-SCA, and Hazardous Drug (HD) storage rooms to all surrounding areas.\nThe report shall indicate whether the area is required to be a negative or positive pressure location as per USP 797 and/or USP 800. All readings and acceptance criteria shall be documented to at least one thousandths of an inch water gauge or water column (e.g., 0.020 w.g. and not 0.02 w.g.) or one tenth of a pascal (e.g., 5.0 Pa). Pressure differentials will be reflected on a report showing the sketch of the room(s).\nSEC Room Pressure Reporting and Documentation\nReport room pressure differential relative to an adjacent room/space\nReport and compare performance of room pressure monitor\nReport whether smoke dispersed at entry doors follows correct direction\nName of test (Room Pressure Differential Test)\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nTotal airborne particle count testing (0.5 micron and larger) in all classified areas performed under dynamic operating conditions as per CETA CAG-003:2022 section 8.1.5 application guide (or most current version). Reporting shall be completed following ISO 14644-01 [2015] section 5.4 Test report and shall include the following:\nThe name and address of the testing organization, and the date on which the test was performed\nThe number and year of publication of this part of ISO 14644 (i.e., ISO 14644 1:2015)\nA clear identification of the physical location of the cleanroom or clean zone testing (including reference to adjacent areas if necessary), and specific designations for coordinates of all sampling locations (a diagrammatic representation can be helpful)\nThe specified designation criteria for the cleanroom or clean zone, including the ISO Class number, the relevant occupancy state(s), and the considered particle size(s)\nDetails of the test method used, with any special conditions relating to the test, or departures from the test method, and identification of the test instrument and its current calibration certificate\nThe test results, including particle concentration data for all sampling locations\nReport acceptance criteria\nProvide a Pass or Fail statement based on the results of the test\nSEC Airflow Visualization Studies (AVS) - Visual Smoke Studies per CETA CAG-014 guide application\nSEC General Temperature and Moisture Tests to verify accuracy of monitoring devices as per CETA CAG-003:2022 section 8.1.7 application guide (or most current version)\nSEC Viable Sampling as per CETA CAG-003:2022 section 8.1.6 and CAG-009:2020 application guides\n\nViable Sampling Testing All viable sampling will conform to USP 797 requirements and performed as per CETA CAG-009 application guide Viable Environmental Monitoring for Sterile Compounding Facilities\nEnvironmental Air Sampling.\nBiannually (every six months) the collection of environmental air samples will be performed by the contractor s CETA technician during certification and during negatively impactful incidents which require repeat air sampling as follows:\nwhenever there is a change to the placement of equipment in the room or any other alteration within the cleanroom suite that affects the quality of the air.\nin response to identified problems and trends.\nin response to changes that could impact the sterile environment (changes in cleaning agents).\nViable air sampling will be performed utilizing a calibrated high-volume impaction sampler during dynamic operating conditions\nSingle plate TSA media which supports growth of both bacteria and fungi will be used to sample. A sufficient volume of air (1000 liters) shall be tested at each location to maximize sensitivity (samples of less than 1000 liters will not be acceptable)\nPositive and negative control plates will be included with sampled plates submitted by the contractor for analysis.\nEnvironmental Surface Sampling.\nBiannually (every six months) the collection of environmental surface samples will be performed by the contractor s CETA technician and during repeated CETA testing. Upon the request of the facility, the contractor will repeat surface sampling as follows:\nwhenever, there is a change to the placement of equipment in the room or any other alteration within the cleanroom suite that affects the quality of the air.\nin response to identified problems and trends.\nin response to changes that could impact the sterile environment (changes in cleaning agents).\nSurface samples will be collected in each room, the interior of each PEC, passthrough chambers connecting to classified areas, and frequently touched surfaces (e.g., door, tables, carts, stools, benches, etc.)\nSurface sampling will be performed at the end of the largest CSP activity of the day but before area has been cleaned and disinfected.\nSingle plate TSA media supplemented with neutralizing additives (e.g., lecithin and polysorbate 80) to neutralize the effects of any residual disinfecting agents will be used.\nRoutine monthly surface sampling will be performed by an appointed trained Northport VAMC personnel. The collected samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis.\nAs needed, appointed trained Northport VAMC personnel will collect surface samples within the PEC as a part of the competency assessment for assigned personnel. The collected samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis.\nPersonnel Viable Sampling.\nThe collection of personnel viable samples for competency testing will be performed by an appointed trained Northport VAMC personnel. The samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis when it is required for personnel competency assessment sampling as follows:\nGloved Fingertip and Thumb (GFT) Testing\nUpon initial assignment compounding staff will be assessed, post hand hygiene and garbing, utilizing GFT samples in triplicate (three samples/hand) for analysis.\nEvery six (6) months and thereafter compounding staff will be assessed, post hand hygiene and garbing, utilizing single collection of GFT samples (one sample/hand) will be collected for analysis post hand hygiene and garbing.\nInitially and every six (6) months thereafter compounding staff will be assessed for GFT during aseptic manipulations, utilizing single collection of GFT samples (one sample/hand) post media fill testing (MFT).\nMedia Fill Test (MFT)\nUpon initial assignment and every six months thereafter, compounding staff will be assessed for aseptic manipulations utilizing USP 797 compliant media fill testing kits.\nOther Viable Sampling Requirements.\nThe laboratory service employed by the contractor must be able to provide the following:\nMicrobial growth media plates which are USP 797 compliant and\ninclude certificates of analysis (COA) from the manufacturer that verify the plates meet the expected growth promotion, pH, and sterilization requirements consistent with USP Chapter 797\ncontain TSA supplemented with neutralizing additives (lecithin and polysorbate 80)\nhave a raised convex surface\nsupport both bacterial and fungal growth on the same plate for single media incubation\nMedia fill testing (MFT) kits compliant to USP 797 and designed to\nsimulate medium complexity (Category 2) sterile IV compounding.\nsimulate low complexity (Category 1) sterile IV compounding.\nA chain of custody documenting each sample collected must be created and provided to the Northport VAMC .\nDuring self-sampling, which is performed by Northport VAMC, the contracted lab is responsible for providing a prepaid mailer for properly sending samples to the laboratory for testing.\nAll samples shipped to the laboratory service must be incubated in accordance with current USP Chapter 797 requirements for duration and temperature.\nAdditional Requirements for PECs and/or SECs Testing\nAny PEC or SEC that fails to meet CETA specifications shall be immediately reported directly to the site-identified point(s) of contact (POC) or appointed ad hoc.\nAreas where hazardous drug handling occurs will be tested by Environmental Wipe Sampling for Hazardous Drug (HD) Residue:\nEvery 6 months, or more frequently as needed to verify contaminant, environmental wipe sampling for HD residue will be performed by an appointed trained Northport VAMC personnel. The collected samples will be shipped to the contractor s laboratory service for HD residue analysis. The kits used to complete HD wipe sampling must be verified prior to use to ensure the sensitivity and validity of the methods and reagents used to recover a specific percentage of known marker drugs.\nThe hazardous drugs (HDs) to be tested will be determined by the facility and may include, but are not limited to:\nCyclophosphamide\nIfosfamide\nFluorouracil\nGemcitabine\nMethotrexate\nPlatinum-containing drugs\nTaxane-based drugs\nOn average 14 surface environmental HD wipe samples will be collected per testing date. The facility can elect to adjust the quantities of samples submitted as needed during investigative remediation. Routine environmental HD wipe sampling will include, at minimum, the following areas:\nInterior of containment primary engineering control (C-PEC) and any equipment contained inside the C-PEC.\nPass-through chambers.\nSurfaces in staging or work areas near C-PEC.\nAreas adjacent to C-PECs (e.g., floors directly under C-PEC, staging, and dispensing area).\nAreas immediately outside the hazardous drug buffer room or C-SCA.\nAreas designated for pharmacist end product verification (checking) / workstations.\nHazardous drug storage areas (including refrigerators).\nHazardous drug receiving areas.\nPatient administration areas.\n\nCompetency of Technician Performing Testing\nCETA testing must be performed by a CNBT individual/company accredited to perform this work. The technician/contractor shall provide a copy of the individuals CETA credentials at time of offer. If, during the contract, a different individual(s) is designated by the contractor, the CETA certification credentials of the assigned individual(s) must be provided to the POC, CO, and COR prior to the start of work.\nTo ensure accurate and reproducible sampling results, environmental viable sampling should be performed by a CETA CNBT technician or a trained technician competent in air and surface sampling procedures. Prior to sampling the contractor must provide the facility documentation records for the individuals training and competencies to perform sampling.\n\nAdditional Contracting Requirements\nCertification periodicities shall be confirmed by contractor, post award, and adjusted as necessary to meet the needs of the Northport VAMC.\nCertification and testing shall conform to USP and OSHA standards.\nTechnician will disinfect and sanitize all equipment brought into the cleanroom suite or segregated compounding area prior to entry (with PreEmptÂ® or PeridoxÂ® (or facility approved disinfectant cleaner), followed by sterile 70% isopropyl alcohol or as per current standard operating procedure for the cleanroom suite).\nContractor will follow Northport VAMC s protocols for use of PPE in the classified spaces and understands the risks associated with facilities and equipment designed for storage and preparation of hazardous drugs.\nThe contractor shall comply with Federal, State, and Local Laws, plus and federal regulations as applicable to the performance of this contract; to include USP Chapter 797 and USP Chapter 800. Contractor must obtain all necessary licenses and/or permits required to perform the work herein.\n\nReporting Results for CETA Testing (including Viable Sampling)\nA General Report Documentation for all CETA test results must be provided via email directly to the COR (Contracting Officer Representative), Chief of Facility Management Services, Chief of Pharmacy Service, and to the Designated Compounding Pharmacist no later than one week after the testing is performed. The CETA report will be a comprehensive informative report of the certification process which will include a statement of compliance or non-compliance regarding the requirements and guidelines outlined respective to CETA Application Guide. The formal report will include as a minimum, but not limited to, the following items:\nName, address, and contact information for the certifying organization also listing key personnel with appropriate accreditations including the name of CETA-certified technician performing the testing.\nConfirming remark that facility/equipment was tested in accordance with CETA CAG-003:2022 (or most current version) and any other applicable performance testing standard followed. The most current version of this CAG must be referenced. Note: USP 797 is not a certification specification.\nExplanation of test procedure used for data collection and justification for any deviations from established industry practices encountered during the certification process.\nA list of test equipment utilized in data collection. List shall include make, model, serial number, and calibration date. A copy of the current calibration documentation for each piece of equipment must be provided when requested.\nRequired reporting values listed in each test section\nType, make, model and serial number for each PEC tested\nEach PEC and SEC nonviable particulate counts (including sample volume and time) and ISO classification\nMeasured air velocity data for PEC, including air flow in CFM, average and standard deviation of air velocity measurements and acceptance criteria\nPEC blower setting and pressure gauge reading (if any)\nFor BSCs:\nmeasured downflow air velocity data, acceptance criteria and pass/fail result\nmeasured exhaust damper acceptance criteria and pass/fail result\ninflow velocity test method, measurements, and results\nDocumentation of results for the video of the airflow smoke pattern test documenting unidirectional flow at critical sites in the PEC.\nTotal Air Changes Per Hour (ACPH) for each SEC, with indication of ACPH supplied by the PECs\nPressure differentials between each SEC and the anteroom/pharmacy\nResults of HEPA leak tests for all filters tested, as well as the results of any patching that was performed\nIf leaks were detected and sealed, include a diagram showing approximate location of sealed leaks\nPrefilter type, size, and condition for each PEC\nSEC temperature and relative humidity\nVideo recording of all smoke pattern testing (airflow and dynamic)\nAlarm test results (if any)\nA diagram of the areas tested, noting the approximate location of air and surface particle counts\nAny recommendations for HEPA replacement/HEPA lifespan\n\nMicrobiological lab analysis reports must meet the following:\nThe laboratory performing microbial analysis must be an American Association for Laboratory Accreditation (A2LA)-accredited laboratory with ISO/IEC 17025 certification for microbiological testing.\nAll viable and non-viable analyzed sampling results must be provided via email directly to the Chief of Facility Management Services, Chief of Pharmacy Service, and to the Designated Compounding Pharmacist no later than 2 weeks after sampling is performed. At a minimum, the provided lab analysis report must include:\nThe manufacturer, lot number, and expiration date for each media lot analyzed.\nDate and time sampling was performed.\nComments indicating sampling under dynamic conditions.\nSampling location(s), with a Site Map sketch identifying location of each sample obtained.\nSampling type and incubation dates, temperature, and duration intervals.\nQuantitative number of discrete colonies of microorganisms on each media device as colony forming units (CFUs) of bacterial/fungal isolates. Results equal to or greater than the action level will require immediate notification to the facility s the POC(s).\nRecovered organisms identified to the genus level (The pharmacy must be notified of any microbial growth immediately after it is identified (no later than 48 hours after the report is received by the contractor from the laboratory).\nDetermination of whether lab findings are actionable (e.g., acceptable/unacceptable as per USP 797).\n\nResponse-Travel- Expense Considerations\nResponse Time- The Contractor shall use commercially reasonable efforts to:\nProvide technical support via telephone to Northport VAMC on a 24/7, 365 days a year schedule.\nRespond by telephone to any report of a malfunction requiring repair within one hour of notification.\nProvide on-site support within 2 hours of notification unless prevented by unforeseen circumstances.\nTravel Time\nDue to the time sensitive nature of testing, the contractor must guarantee a maximum two-hour time travel and arrival at facility on scheduled testing dates for any required testing personnel and equipment.\nTravel Expenses-\nContractor shall be responsible for all service-related equipment shipping and tester s trip expenses, including but not limited to round trip travel, mileage, meals, and overnight living expenses.\n\nTitle to Equipment- Contractor shall not assume possession or control of any part of the equipment. The Government retains ownership to title thereof.\n\nUtilities- Contractor may use Government utilities, (e.g., electrical power, compressed air, and water) which are available and required for any service performed under this contract.\n\nAccess to Equipment- Contractor shall be provided reasonable access to all equipment that is to be serviced and utility outlets required to do the service. The contractor shall be free to start and stop all primary equipment incidentals to the operation of the maintained equipment after permission is received from on duty personnel responsible for such equipment.\n\nParts and Materials- All compensation for parts and materials is included in contract price.\n\nParts/Supplies Quality- Parts and Supplies provided under this contract shall be new OEM (Original Equipment Manufacturer) parts.\n\nField Service Reports- Contractor shall furnish a written or electronic vendor supplied Field Service Report (FSR).\n\nPlace of Performance.\nNorthport VAMC\n79 Middleville Road\nNorthport, N.Y. 11768\n\nPeriod of Performance.\nBase plus four (4) option years\n\nInformation Security/Privacy/ Records Management\nThis contract does not involve access to VA patient/employee information and does not involve access and/or connection to the VA information system.\n\nVA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or the Use of VA Sensitive Information\n\nThe Department of Veterans Affairs, VA must comply with all applicable privacy and confidentiality statutes and regulations. One of the requirements in VA is to have all personnel trained annually on privacy requirements. Privacy represents what must be protected by VA in the collection, use, and disclosure of personal information whether the medium is electronic, paper or verbal.\nThis document (20939 training) satisfies the basic privacy training requirement for a contractor, volunteer, or other personnel only if the individual does not use VA sensitive information or protected health information (PHI) in any form such as electronic or paper or have access to any VA computer system.\nThe Contracting Officer Representative (COR/ COTR/ Project Manager) is responsible to obtain this training from the contractor and to maintain according to the Records Control Schedule (RCS 10-1).","html":"The Department of Veterans Affairs Network Contracting Office 2 is issuing this source sought synopsis as a means of conducting market research to identify parties having an interest in and the resources providing Testing of Sterile Compounding Areas at the Northport VAMC, 79 Middleville Road , Northport, NY 11768.\nThe result of this market research will contribute to determining the method of procurement. The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 541380.\nThe VA requires a 12-month base year, plus four 12-month options contract. This contract will be inclusive of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION. \nTelephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\nSubmission Instructions: Interested parties who consider themselves qualified to perform the above listed services are invited to submit a response to this Sources Sought Notice by October 24, 2024, at 12:00PM EST. All responses under this Sources Sought Notice must be emailed to Lee.Kern@va.gov.\nPlease see the below Statement of Work (SOW):\nSTATEMENT OF WORK\nTesting of Sterile Compounding Areas\n\nINTRODUCTION\n United States Pharmacopeia (USP) establishes standards for cleanroom design, environmental monitoring, and competencies for the preparation, handling, and storage of compounded sterile preparations (CSPs).  To maintain compliance with these standards, Northport VAMC requires a Base plus four (4) year contract inclusive of all labor, materials, equipment, and travel (within 2 hours) to perform initial and recurring certification of the facility s sterile compounding areas. Certification and testing will consist of:\n testing all primary engineering controls [(PECs) e.g., biological safety cabinets (BSCs), laminar airflow workbenches (LAFWs), compounding aseptic containment isolators (CACI), and compounding aseptic isolators (CAI)]\ntesting all secondary engineering controls (SECs), non-ISO rated controlled non-classified (CNC) rooms, and High-efficiency particulate air (HEPA) filtration devices. \nmicrobiological laboratory testing of collected viables samples.\nwipe sampling for environmental Hazardous Drug (HD) residue\n\nTesting and certification must be completed in accordance with the most currently published versions of  USP Chapter <797> , USP Chapter <800>, Controlled Environment Testing Association (CETA) Application Guides for: CAG-003 Certification of Sterile Compounding Facilities for USP Compliance, CAG-002 Compounding Isolator Testing, CAG-008 Certification Matrix for\nSterile & Nonsterile USP Compounding Facilities, CAG-009 Viable Environmental Monitoring for Sterile Compounding Facilities, CAG-014 Airflow Visualization Study, National Sanitation Foundation/American National Standards Institute (NSF/ANSI) Standard 49 Biosafety Cabinetry, and Institute of Flow Clean Air Devices, IEST-RP-CC-002.4. All lab analysis of viable samples must be performed by a facility with ISO/IEC 17025 accreditation for microbial analysis. This environmental quality testing may not be performed under the laboratory s Clinical Laboratory Improvement Amendments (CLIA) license. The lab must attain ISO/IEC 17025 certification from an external accrediting body (e.g., American Association for Laboratory Accreditation ) to ensure quality and accuracy of the testing.\n\nBACKGROUND. \nNorthport VAMC is pursuing a facility contract for certification of all PECs, SECs, CNC rooms, and HEPA filters must be performed pursuant to the most current version of USP Chapter <797> and USP Chapter <800> standards following CETA s  standardized testing procedures which include (but is not limited to) CAG-003 CETA Certification Guide for Sterile Compounding Facilities for USP Compliance, CAG-002 CETA Compounding Isolator Testing Guide, CAG-014 Airflow Visualization Study, and CAG-009 Viable Environmental Monitoring for Sterile Compounding Facilities.\n \nCertification must be performed every 6 months. Recertification will be required after any servicing of facilities or equipment, post changes to the area that could affect airflow or air quality ( e.g., redesign,  construction, replacement or relocation of any PEC, or alteration in the configuration of the room), and/or in response to identified problems or trends.  \n\nCertification procedures defined in relevant CETA Application Guides must be  performed no less than every 6 months by an individual who has the required CETA competencies and training related to the certification of primary and secondary engineering controls. Additionally, it is preferred that the on-site certification individual have received NSF accreditation for the field certification of Class II Biosafety Cabinets and are accredited through CNBT as a registered certification professional in the sterile compounding facility (RCP-SCF). Prior to testing, the contractor s technician(s) who conduct on-site certification will provide, to the COR, documentation of competency and training related to the certification of PECs and SECs. \n\nProcedures for air and surface sampling and evaluation must be compliant as per the most current USP Chapter 797 requirements for environmental air sampling, surface sampling (CAG-009), gloved fingertip testing (CAG-011), and media fill testing (CAG-013) following the appropriate CETA CAG application guide.\n\nNorthport VAMC s sterile compounding areas and equipment must be compliant to The Joint Commission (TJC) and Food and Drug Administration (FDA) requirements. TJC Medication Compounding Requirements for Critical Access Hospitals and Hospitals, effective January 1, 2024, established new Medication Compounding (MC) standards for non-sterile and sterile compounded preparations which are based on USP standards.  The FDA has the authority to inspect VA medical facilities under the Food, Drug and Cosmetic Act, and evaluate based upon the guidance provided in the Insanitary Conditions at Compounding Facilities Guidance for Industry, November 2020 (or most current version).\n\nSCOPE \nTesting Frequency. \nThe Northport VAMC has a requirement for onsite initial and reoccurring CETA certification and viable environmental sampling of the facility s Pharmacy-specific and non-Pharmacy specific areas and equipment as detailed within this Statement of Work (SOW).  Testing and certification dates contained within this SOW are best documented; Contractor shall be responsible to confirm and/or adjust certification/testing requirements to ensure no lapse in requirements and thus no undesirable effect on the mission of the Northport VAMC.\nAll pharmacy-specific equipment will minimally obtain CETA certification every six (6) calendar months from the date of the last certification/testing of BSCs, LAFWs, CAI, CACI, HEPA filters, and room spaces/environments in accordance with VHA Directive 1108.12 (see attachment A), and USP 797 (Attachment B) & 800 (Attachment C). Recertification may be required sooner if equipment is relocated/altered, or a major service is performed.\n\nTesting Locations. The following location shall be tested as per USP 797 and where applicable USP 800 standards as per respective CETA guide applications. Locations may be amended as per the facility s renovations and construction.\nBuilding 200, Unit 31 Cleanroom suite(s) Primary Space(s) and equipment\nISO-8 Anteroom(s): Two ceiling mounted HEPA filters\nISO-7 Buffer room(s)\nTwo ceiling mounted HEPA filters\nOne ISO-5 LAWF: Baker Edgegard 5252 LAWF \nBuilding 200, Inpatient: One ISO-5 Compounding Aseptic Isolator (CAI): Baker SS-500\nBuilding 200, New pavilion 2F, E2-49\nHD negative pressure storage room: One ceiling mounted HEPA filter\nCNC HD negative pressure C-SCA\nOne ceiling mounted HEPA filter\nOne ISO-5 HD negative pressure Compounding Aseptic Containment Isolator (CACI): Baker CS-500\nGermFree Trailer (adjacent to building 11) - This location will be covered under this contract for monthly viable sampling and hazardous drug wipe sampling. \nNote: There is a separate contract which covers the semiannual CETA testing and viable sampling of the trailer.\n\nTesting Requirements of PECs.\nBiological safety cabinet (BSC): On-site certifications of the BSCs shall be tested to manufacturer specifications in accordance with the most recent version of NSF/ANSI Standard 49 Biosafety Cabinetry (as per CETA CAG-003:2022 section 8.2. through 8.2.5 application guide and CETA CAG-005:2007 (or most current versions)\nCompounding Aseptic Isolator (CAI) and Compounding Aseptic Containment Isolator (CACI):  The contractor shall test and certify all CAIs and CACIs as per CETA CAG-003 sections 8.3 through 8.3.5 and in accordance with CETA CAG-002 guide application. \nLaminar Air Flow Workbench (LAFW): The contractor shall test and certify all LAFW as per CETA CAG-003:2022 section 8.4. through 8.4.6 application guide (or most current version)\nThe contractor shall test and certify all PECs in accordance with the most current version of The Institute of Environmental Sciences and Technology (IEST)-RP-CC002 (Unidirectional Flow Clean-Air Devices), CETA CAG-003, and the manufacturer's specifications.\nThe contractor shall record each individual face velocity reading and the average of those readings, the downstream concentration reading of the HEPA filter leak test and the results of the induction leak test and back streaming test\nAll equipment used to certify PECs must be calibrated in accordance with IEST-RP-CC013 or manufacturer's recommendation and be NIST traceable where possible.\nWhere applicable the list of tests for PECs includes, where applicable but not limited to the following:\nAir flow velocity profile\nAir flow visualization profile: dynamic smoke pattern testing (video recorded and provided to us on a thumb drive or made available for download on a secure website) for all primary engineering controls. Tester must utilize sufficient smoke to demonstrate unidirectional airflow at critical sites and sweeping action over and away from preparations.\nPrefilter check\nHEPA/ULPA filter leak integrity testing (must be performed upon installation and as part of certification)\nInduction leak integrity test and patching if necessary\nElectrical leakage and ground circuit resistance and polarity tests\nPreparation ingress and egress test where applicable\nChamber pressure test\nTotal airborne non-viable particle count testing in all classified areas performed under dynamic operating conditions \nFor each PEC passing the required certification tests, the contractor supplies each unit with a certification tag or sticker displaying the following information:\nCompany name and contact information.\nUnit make, model and serial number.\nReport number\nLocation (e.g., building, room number, area identification)\nCertification date\nRecertification date\nTechnician name and signature\nAny PEC that fails to meet CETA specifications shall be clearly marked with signage which alerts compounding personnel that the unit is  out of order until further notice.  \n\nTesting Requirements of SECs.\nThe contractor will provide comprehensive cleanroom testing and certification services every 6 months, in the event of an environmental or engineering control excursion/exceedance or sooner if there are changes to the area such as redesign, construction, replacement or relocation of any PEC, or alteration in the configuration of the room that could affect airflow or air quality or if a cleanroom(s) did not meet compliance.  Certification tests for rooms within a cleanroom suite include, but are not limited to:\nAirflow testing: HEPA filter(s) air volumes and velocities will be measured and documented as per CETA CAG-003:2022 section 8.1.1 application guide (or most current version)\n Airflow testing is performed to determine acceptability of the air velocity, the room air exchange rate, and the room pressure differential in doorways between adjacent rooms to ensure consistent airflow and that the appropriate quality of air is maintained under dynamic operating conditions.\nThe contractor shall calculate the total room area and volume for each buffer room, anteroom, Containment segregated compounding area (C-SCA), and hazardous drug storage room. The ISO classification and a sketch of the room with dimensions, exhaust/supply diffuser locations and equipment locations shall be included in the report.  The report provided will specify flow rates detailing returns and supply that were obtained during the testing. The contractor shall calculate air changes per hour (ACPH) for each buffer and anteroom and include their findings in the report.  ACPH for HVAC, ACPH contributed from PEC, and the total ACPH. Comparison of ACPH will be completed both for USP 797 standards as well as those referenced in the VHA HVAC Design Manual (Attachment D or earlier version if available), which are further stringent than USP Chapter 797.\nISO Classified Turbulent Airflow Area Reporting and Documentation\nRecord all airflow measurements and their corresponding filter or diffuser locations or grid identifications on a diagram \nCalculate and report room volume \nCalculate and report the average total room airflow volume \nCalculate and report the total air changes per hour of the room (include LAFW and/or Non-ducted BSC HEPA exhaust to room, where applicable) \nReport any correction factors used or deviations from the primary method  \nName of test (e.g., Room Airflow Analysis) \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nNon-ISO Classified Negative Pressure Turbulent Airflow Area Testing Procedure including ACPH requirements for containment segregated compounding areas and  hazardous drug storage areas, must be a minimum of 12 exhaust ACPH. Because these rooms/areas are not ISO classified airflow measurements should be taken on the exhaust of negative pressure differential rooms. Non-ISO Classified Negative Pressure Turbulent Airflow Reporting and Documentation must include:\nRecord all airflow measurements and their corresponding exhaust filter or exhaust grill locations \nCalculate and report room volume \nCalculate and report the average total room airflow volume \nCalculate and report the total air changes per hour of the room  \nReport any correction factors used or deviations from the primary method  \nName of test (e.g., Unclassified Negative Pressure Room Airflow Analysis) \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nSEC HEPA filter integrity testing performed as per CETA CAG-003:2022 section 8.1.2 application guide (or most current version)\nRecord upstream aerosol challenge concentration \nList method used to report concentration (measured or calculated) \nRecord maximum leak penetration in percent \nName of test (HEPA Filter Leak Test) \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nSEC Room Pressure Differential/Room Pressurization as per CETA CAG-003:2022 section 8.1.3 application guide (or most current version)\nThe contractor shall include in their report differential pressure readings from each buffer room, anteroom, C-SCA, and Hazardous Drug (HD) storage rooms to all surrounding areas.\nThe report shall indicate whether the area is required to be a negative or positive pressure location as per USP 797 and/or USP 800. All readings and acceptance criteria shall be documented to at least one thousandths of an inch water gauge or water column (e.g., 0.020  w.g. and not 0.02  w.g.) or one tenth of a pascal (e.g., 5.0 Pa).  Pressure differentials will be reflected on a report showing the sketch of the room(s).\nSEC Room Pressure Reporting and Documentation\nReport room pressure differential relative to an adjacent room/space \nReport and compare performance of room pressure monitor \nReport whether smoke dispersed at entry doors follows correct direction \nName of test (Room Pressure Differential Test) \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nTotal airborne particle count testing (0.5 micron and larger) in all classified areas performed under dynamic operating conditions  as per CETA CAG-003:2022 section 8.1.5 application guide (or most current version). Reporting shall be completed following ISO 14644-01 [2015] section 5.4  Test report  and shall include the following:  \nThe name and address of the testing organization, and the date on which the test was performed \nThe number and year of publication of this part of ISO 14644 (i.e., ISO 14644 1:2015) \nA clear identification of the physical location of the cleanroom or clean zone  testing (including reference to adjacent areas if necessary), and specific  designations for coordinates of all sampling locations (a diagrammatic  representation can be helpful) \nThe specified designation criteria for the cleanroom or clean zone, including the ISO Class number, the relevant occupancy state(s), and the considered particle size(s) \nDetails of the test method used, with any special conditions relating to the test, or departures from the test method, and identification of the test instrument and its current calibration certificate \nThe test results, including particle concentration data for all sampling locations \nReport acceptance criteria \nProvide a Pass or Fail statement based on the results of the test\nSEC Airflow Visualization Studies (AVS) - Visual Smoke Studies per CETA CAG-014 guide application\nSEC General Temperature and Moisture Tests to verify accuracy of monitoring devices as per CETA CAG-003:2022 section 8.1.7 application guide (or most current version)\nSEC Viable Sampling as per CETA CAG-003:2022 section 8.1.6 and CAG-009:2020 application guides\n\nViable Sampling Testing  All viable sampling will conform to USP 797 requirements and performed as per CETA CAG-009 application guide Viable Environmental Monitoring for Sterile Compounding Facilities \nEnvironmental Air Sampling. \nBiannually (every six months) the collection of environmental air samples will be performed by the contractor s CETA technician during certification and during negatively impactful incidents which require repeat air sampling as follows:\nwhenever there is a change to the placement of equipment in the room or any other alteration within the cleanroom suite that affects the quality of the air.\nin response to identified problems and trends.\nin response to changes that could impact the sterile environment (changes in cleaning agents).\nViable air sampling will be performed utilizing a calibrated high-volume impaction sampler during dynamic operating conditions \n Single plate TSA media which supports growth of both bacteria and fungi will be used to sample.  A sufficient volume of air (1000 liters) shall be tested at each location to maximize sensitivity (samples of less than 1000 liters will not be acceptable)\nPositive and negative control plates will be included with sampled plates submitted by the contractor for analysis.\nEnvironmental Surface Sampling. \nBiannually (every six months) the collection of environmental surface samples will be performed by the contractor s CETA technician and during repeated CETA testing. Upon the request of the facility, the contractor will repeat surface sampling as follows:\nwhenever, there is a change to the placement of equipment in the room or any other alteration within the cleanroom suite that affects the quality of the air.\nin response to identified problems and trends.\nin response to changes that could impact the sterile environment (changes in cleaning agents).\nSurface samples will be collected in each room, the interior of each PEC, passthrough chambers connecting to classified areas, and frequently touched surfaces (e.g., door, tables, carts, stools, benches, etc.)  \nSurface sampling will be performed at the end of the largest CSP activity of the day but before area has been cleaned and disinfected.  \nSingle plate TSA media supplemented with neutralizing additives (e.g., lecithin and polysorbate 80) to neutralize the effects of any residual disinfecting agents will be used.\nRoutine monthly surface sampling will be performed by an appointed trained Northport VAMC personnel. The collected samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis.\nAs needed, appointed trained Northport VAMC personnel will collect surface samples within the PEC as a part of the competency assessment for assigned personnel. The collected samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis.\nPersonnel Viable Sampling.\n The collection of personnel viable samples for competency testing will be performed by an appointed trained Northport VAMC personnel. The samples will be shipped to the laboratory service employed by the contractor for incubation and microbiological analysis when it is required for personnel competency assessment sampling as follows:\nGloved Fingertip and Thumb (GFT) Testing \nUpon initial assignment compounding staff will be assessed, post hand hygiene and garbing, utilizing GFT samples in triplicate (three samples/hand) for analysis.\nEvery six (6) months and thereafter compounding staff will be assessed, post hand hygiene and garbing, utilizing single collection of GFT samples (one sample/hand) will be collected for analysis post hand hygiene and garbing.\nInitially and every six (6) months thereafter compounding staff will be assessed for GFT during aseptic manipulations, utilizing single collection of GFT samples (one sample/hand) post media fill testing (MFT).\nMedia Fill Test (MFT) \nUpon initial assignment and every six months thereafter,  compounding staff will be assessed  for aseptic manipulations utilizing USP 797 compliant media fill testing kits.\nOther Viable Sampling Requirements. \nThe laboratory service employed by the contractor must be able to provide the following:\nMicrobial growth media plates which are USP 797 compliant and\ninclude certificates of analysis (COA) from the manufacturer that verify the plates meet the expected growth promotion, pH, and sterilization requirements consistent with USP Chapter 797\ncontain TSA supplemented with neutralizing additives (lecithin and polysorbate 80)\nhave a raised convex surface\nsupport both bacterial and fungal growth on the same plate for single media incubation\nMedia fill testing (MFT) kits compliant to USP 797 and designed to\n simulate medium complexity (Category 2) sterile IV compounding.\nsimulate low complexity (Category 1) sterile IV compounding. \nA chain of custody documenting each sample collected must be created and provided to the Northport VAMC . \nDuring self-sampling, which is performed by Northport VAMC, the contracted lab is responsible for providing a prepaid mailer for properly sending samples to the laboratory for testing.\nAll samples shipped to the laboratory service must be incubated in accordance with current USP Chapter 797 requirements for duration and temperature.\nAdditional Requirements for PECs and/or SECs Testing\nAny PEC or SEC that fails to meet CETA specifications shall be immediately reported directly to the site-identified point(s) of contact (POC) or appointed ad hoc. \nAreas where hazardous drug handling occurs will be tested by Environmental Wipe Sampling for Hazardous Drug (HD) Residue:\nEvery 6 months, or more frequently as needed to verify contaminant, environmental wipe sampling for HD residue will be performed by an appointed trained Northport VAMC personnel. The collected samples will be shipped to the contractor s laboratory service for HD residue analysis.  The kits used to complete HD wipe sampling must be verified prior to use to ensure the sensitivity and validity of the methods and reagents used to recover a specific percentage of known marker drugs.\nThe hazardous drugs (HDs) to be tested will be determined by the facility and may include, but are not limited to:\nCyclophosphamide\nIfosfamide\nFluorouracil\nGemcitabine\nMethotrexate\nPlatinum-containing drugs\nTaxane-based drugs\nOn average 14 surface environmental HD wipe samples will be collected per testing date. The facility can elect to adjust the quantities of samples submitted as needed during investigative remediation. Routine environmental HD wipe sampling will include, at minimum, the following areas:\nInterior of containment primary engineering control (C-PEC) and any equipment contained inside the C-PEC.\nPass-through chambers.\nSurfaces in staging or work areas near C-PEC.\nAreas adjacent to C-PECs (e.g., floors directly under C-PEC, staging, and dispensing area).\nAreas immediately outside the hazardous drug buffer room or C-SCA.\nAreas designated for pharmacist end product verification (checking) / workstations.\nHazardous drug storage areas (including refrigerators).\nHazardous drug receiving areas.\nPatient administration areas.\n\nCompetency of Technician Performing Testing\nCETA testing must be performed by a CNBT individual/company accredited to perform this work. The technician/contractor shall provide a copy of the individuals CETA credentials at time of offer. If, during the contract, a different individual(s) is designated by the contractor, the CETA certification credentials of the assigned individual(s) must be provided to the POC, CO, and COR prior to the start of work.\nTo ensure accurate and reproducible sampling results, environmental viable sampling should be performed by a CETA CNBT technician or a trained technician competent in air and surface sampling procedures. Prior to sampling the contractor must provide  the facility documentation records for the individuals training and competencies to perform sampling.\n\nAdditional Contracting Requirements\nCertification periodicities shall be confirmed by contractor, post award, and adjusted as necessary to meet the needs of the Northport VAMC. \nCertification and testing shall conform to USP and OSHA standards.\nTechnician will disinfect and sanitize all equipment brought into the cleanroom suite or segregated compounding area prior to entry (with PreEmptÂ® or PeridoxÂ® (or facility approved disinfectant cleaner), followed by sterile 70% isopropyl alcohol or as per current standard operating procedure for the cleanroom suite).\nContractor will follow Northport VAMC s protocols for use of PPE in the classified spaces and understands the risks associated with facilities and equipment designed for storage and preparation of hazardous drugs.\nThe contractor shall comply with Federal, State, and Local Laws, plus and federal regulations as applicable to the performance of this contract; to include USP Chapter 797 and USP Chapter 800. Contractor must obtain all necessary licenses and/or permits required to perform the work herein.\n\nReporting Results for CETA Testing (including Viable Sampling)\nA  General Report Documentation  for all CETA test results must be provided via email directly to the COR (Contracting Officer Representative), Chief of Facility Management Services, Chief of Pharmacy Service, and to the Designated Compounding Pharmacist no later than one week after the testing is performed. The CETA report will be a comprehensive informative report of the certification process which will include a statement of compliance or non-compliance regarding the requirements and guidelines outlined respective to CETA Application Guide.  The formal report will include as a minimum, but not limited to, the following items:\nName, address, and contact information for the certifying organization also listing key personnel with appropriate accreditations including the name of CETA-certified technician performing the testing.\nConfirming remark that facility/equipment was tested  in accordance with CETA CAG-003:2022 (or most current version) and any other applicable performance testing standard followed. The most current version of this CAG must be referenced. Note: USP 797 is not a certification specification.  \nExplanation of test procedure used for data collection and justification for any deviations from established industry practices encountered during the certification process.  \nA list of test equipment utilized in data collection. List shall include make, model, serial number, and calibration date. A copy of the current calibration documentation for each piece of equipment must be provided when requested.\nRequired reporting values listed in each test section \nType, make, model and serial number for each PEC tested\nEach PEC and SEC nonviable particulate counts (including sample volume and time) and ISO classification\nMeasured air velocity data for PEC, including air flow in CFM, average and standard deviation of air velocity measurements and acceptance criteria\nPEC blower setting and pressure gauge reading (if any)\nFor BSCs: \nmeasured downflow air velocity data, acceptance criteria and pass/fail result\nmeasured exhaust damper acceptance criteria and pass/fail result\ninflow velocity test method, measurements, and results\nDocumentation of results for the video of the airflow smoke pattern test documenting unidirectional flow at critical sites in the PEC.\nTotal Air Changes Per Hour (ACPH) for each SEC, with indication of ACPH supplied by the PECs\nPressure differentials between each SEC and the anteroom/pharmacy\nResults of HEPA leak tests for all filters tested, as well as the results of any patching that was performed\nIf leaks were detected and sealed, include a diagram showing approximate location of sealed leaks\nPrefilter type, size, and condition for each PEC\nSEC temperature and relative humidity\nVideo recording of all smoke pattern testing (airflow and dynamic)\nAlarm test results (if any)\nA diagram of the areas tested, noting the approximate location of air and surface particle counts\nAny recommendations for HEPA replacement/HEPA lifespan\n\nMicrobiological lab analysis reports must meet the following:\nThe laboratory performing microbial analysis must be an American Association for Laboratory Accreditation (A2LA)-accredited laboratory with ISO/IEC 17025 certification for microbiological testing.\nAll viable and non-viable analyzed sampling results must be provided via email directly to the Chief of Facility Management Services, Chief of Pharmacy Service, and to the Designated Compounding Pharmacist no later than 2 weeks after sampling is performed. At a minimum, the provided lab analysis report must include:\nThe manufacturer, lot number, and expiration date for each media lot analyzed.\nDate and time sampling was performed.\nComments indicating sampling under dynamic conditions.\nSampling location(s), with a Site Map sketch identifying location of each sample obtained.\nSampling type and incubation dates, temperature, and duration intervals.\nQuantitative number of discrete colonies of microorganisms on each media device as colony forming units (CFUs) of bacterial/fungal isolates. Results equal to or greater than the action level will require immediate notification to the facility s the POC(s).\nRecovered organisms identified to the genus level (The pharmacy must be notified of any microbial growth immediately after it is identified (no later than 48 hours after the report is received by the contractor from the laboratory). \nDetermination of whether lab findings are actionable (e.g., acceptable/unacceptable as per USP 797).\n\nResponse-Travel- Expense Considerations\nResponse Time- The Contractor shall use commercially reasonable efforts to:\nProvide technical support via telephone to Northport VAMC on a 24/7, 365 days a year schedule.\nRespond by telephone to any report of a malfunction requiring repair within one hour of notification.\nProvide on-site support within 2 hours of notification unless prevented by unforeseen circumstances.\nTravel Time\nDue to the time sensitive nature of testing, the contractor must guarantee a maximum two-hour time travel and arrival at facility on scheduled testing dates for any required testing personnel and equipment.\nTravel Expenses-\nContractor shall be responsible for all service-related equipment shipping and tester s trip expenses, including but not limited to round trip travel, mileage, meals, and overnight living expenses.\n\nTitle to Equipment- Contractor shall not assume possession or control of any part of the equipment. The Government retains ownership to title thereof.\n\nUtilities- Contractor may use Government utilities, (e.g., electrical power, compressed air, and water) which are available and required for any service performed under this contract.\n\nAccess to Equipment- Contractor shall be provided reasonable access to all equipment that is to be serviced and utility outlets required to do the service. The contractor shall be free to start and stop all primary equipment incidentals to the operation of the maintained equipment after permission is received from on duty personnel responsible for such equipment.\n\nParts and Materials- All compensation for parts and materials is included in contract price.\n\nParts/Supplies Quality- Parts and Supplies provided under this contract shall be new OEM (Original Equipment Manufacturer) parts.\n\nField Service Reports- Contractor shall furnish a written or electronic vendor supplied Field Service Report (FSR).\n\nPlace of Performance. \nNorthport VAMC\n79 Middleville Road\nNorthport, N.Y. 11768\n\nPeriod of Performance.\nBase plus four (4) option years\n\n\nInformation Security/Privacy/ Records Management\nThis contract does not involve access to VA patient/employee information and does not involve access and/or connection to the VA information system.\n\nVA Privacy Training for Personnel without Access to VA Computer Systems or Direct Access to or the Use of VA Sensitive Information\n\nThe Department of Veterans Affairs, VA must comply with all applicable privacy and confidentiality statutes and regulations. One of the requirements in VA is to have all personnel trained annually on privacy requirements.  Privacy  represents what must be protected by VA in the collection, use, and disclosure of personal information whether the medium is electronic, paper or verbal.\nThis document (20939 training) satisfies the  basic  privacy training requirement for a contractor, volunteer, or other personnel only if the individual does not use VA sensitive information or protected health information (PHI) in any form such as electronic or paper or have access to any VA computer system.\nThe Contracting Officer Representative (COR/ COTR/ Project Manager) is responsible to obtain this training from the contractor and to maintain according to the Records Control Schedule (RCS 10-1).","origin":"detail"},"contacts":[{"name":"Lee Kern","role":"primary","email":"Lee.Kern@va.gov","phone":"607-664-4748","title":"Contract Specialist"}],"place_of_performance":{"zip":"11768","city":{"name":"Northport"},"state":{"code":"NY","name":"New York"},"street":"Department of Veterans Affairs Northport VAMC","country":{"code":"USA","name":"UNITED STATES"},"street2":"79 Middleville Road"},"office_address":{"zip":"12208","city":"ALBANY","state":"NY","country":"USA"},"naics_codes":["541380"],"award":{"awardee":{}},"attachments":[{"resource_id":"578fbaa4caa74fa2863584fa5d50658f","name":"36C24225Q0222.docx","kind":"file","mime_type":".docx","size_bytes":124221,"posted_at":"2025-01-23T15:00:34.696Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/578fbaa4caa74fa2863584fa5d50658f/download","mirrored":false},{"resource_id":"aa6b5e1b281945b49e8f66cb1871cd73","name":"36C24225Q0222_1.docx","kind":"file","mime_type":".docx","size_bytes":34207,"posted_at":"2025-01-23T14:59:38.862Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/aa6b5e1b281945b49e8f66cb1871cd73/download","mirrored":false}],"awards":[],"related":[{"key":"36C24226R0115","latest_notice_id":"90161704ac554dd8b698d6922b32b544","title":"X1DB--Valley Stream CBOC - New Replacing Lease (VA-28-00000026)","solicitation_number":"36C24226R0115","notice_type":"r","first_type":"r","first_posted":"2026-11-06","last_posted":"2026-11-06","notices":1,"due_at":"2026-11-27T09:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T09:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"531120","psc":"X1DB","set_aside":null,"state":"NY","county":"36059","county_name":"Nassau County","city":"3676705","city_name":"Valley Stream","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-07T04:54:53.607561Z"},{"key":"36C24227R0010","latest_notice_id":"c95dcd81879b4a90b11678c8a80b3462","title":"F108--620-26-206 Asbestos Abatement","solicitation_number":"36C24227R0010","notice_type":"o","first_type":"p","first_posted":"2026-10-23","last_posted":"2026-11-19","notices":8,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"562910","psc":"F108","set_aside":"SDVOSBC","state":"NY","county":"36119","county_name":"Westchester County","city":"3648208","city_name":"Montrose","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C24227Q0135","latest_notice_id":"878a17ea716349ce875349b4308f3e10","title":"Y1DA--STATION-CONST TBD OIG RENOVATION","solicitation_number":"36C24227Q0135","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":2,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"236220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"ANTEEN OPERATIONS. LOCATION: MARGARET COCHRAN CORBIN VA CAMPUS 423 EAST, 23RD STREET NEW YORK, NY 10010","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0122","latest_notice_id":"ab2010ecef12446face409c44090d58a","title":"8910--East Orange Milk and Dairy","solicitation_number":"36C24227Q0122","notice_type":"o","first_type":"p","first_posted":"2026-11-09","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"311511","psc":"8910","set_aside":"SBA","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8910)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open":[{"key":"BSA478026SOLICITATION","latest_notice_id":"eb7eba8640fc4f38bec639f6808df92a","title":"Analytical Services","solicitation_number":"BSA478026-Solicitation","notice_type":"o","first_type":"o","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-12-14T17:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-089","dept_name":"ENERGY, DEPARTMENT OF","sub_key":"s-8900","sub_name":"ENERGY, DEPARTMENT OF","office_key":"o-899033","office_name":"BROOKHAVEN NATL LAB -DOE CONTRACTOR","naics":"541380","psc":"B599","set_aside":null,"state":"NY","county":"36103","county_name":"Suffolk County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"75N98027Q00086","latest_notice_id":"9b77d1c7a98245099c34f29277d6d927","title":"Storage and monitoring of ManNac for FDA regulations","solicitation_number":"75N98027Q00086","notice_type":"p","first_type":"p","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T14:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"541380","psc":"6505","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24927AP1027","latest_notice_id":"6960cc2ab4be4d428eac6e0f6ece061f","title":"APT Generator Switchgear Testing – Alvin C. York VA Medical Center","solicitation_number":"36C249-27-AP-1027","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-26T18:00:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C249","office_name":"249-NETWORK CONTRACT OFFICE 9 (36C249)","naics":"541380","psc":"H261","set_aside":null,"state":"TN","county":"47149","county_name":"Rutherford County","city":"4751560","city_name":"Murfreesboro","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":34,"indexable":false}