{"canonical":"https://sealedbidder.com/opportunities/36c24126q0497","key":"36C24126Q0497","url":"https://sealedbidder.com/opportunities/36c24126q0497","title":"J042--Door Inspections and Repair Service Contract","solicitation_number":"36C24126Q0497","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-07-02T19:00:00Z","first_posted":"2026-05-15","last_posted":"2026-09-09","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541350","psc":"J042","set_aside":"SDVOSBC","place_state":"NH","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"33011","place_county_name":"Hillsborough County","place_city":"3345140","place_city_name":"Manchester","winner":"HURTVET SUBCONTRACTING, INC.","award_amount":"981180.00","publications":[{"notice_id":"0377e6b3fc0f495dae7a41080cc3aecb","title":"J042--Door Inspections and Repair Service Contract","solicitation_number":"36C24126Q0497","notice_type":"k","base_type":"k","posted":"2026-05-15","posted_at":"2026-05-15T17:51:55.672Z","due_at":"2026-06-04T21:00:00Z","due_date":"2026-06-04","cancelled":false,"archived":true,"archive_date":"2026-07-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0377e6b3fc0f495dae7a41080cc3aecb/view","enriched":true,"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}]},{"notice_id":"03798b450615493fb5e0d5943e679d8c","title":"J042--Door Inspections and Repair Service Contract","solicitation_number":"36C24126Q0497","notice_type":"k","base_type":"k","posted":"2026-05-15","posted_at":"2026-05-15T17:39:11.402Z","due_at":"2026-06-04T21:00:00Z","due_date":"2026-06-04","cancelled":false,"archived":true,"archive_date":"2026-07-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/03798b450615493fb5e0d5943e679d8c/view","enriched":true,"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}]},{"notice_id":"03ffaa2252df43daa68090eaad34594e","title":"J042--Door Inspections and Repair Service Contract","solicitation_number":"36C24126Q0497","notice_type":"k","base_type":"k","posted":"2026-05-15","posted_at":"2026-05-15T17:55:15.034Z","due_at":"2026-06-04T21:00:00Z","due_date":"2026-06-04","cancelled":false,"archived":true,"archive_date":"2026-07-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/03ffaa2252df43daa68090eaad34594e/view","enriched":true,"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}]},{"notice_id":"09d88714ec5a4550a4980f4f2177439b","title":"J042--Door Inspections and Repair Service Contract","solicitation_number":"36C24126Q0497","notice_type":"k","base_type":"k","posted":"2026-06-24","posted_at":"2026-06-24T20:10:37.617Z","due_at":"2026-07-02T19:00:00Z","due_date":"2026-07-02","cancelled":false,"archived":true,"archive_date":"2026-08-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/09d88714ec5a4550a4980f4f2177439b/view","enriched":true,"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}]},{"notice_id":"3bda2571f43c494eb3fbc14dc08da82a","title":"J042--Door Inspections and Repair Service Contract","solicitation_number":"36C24126Q0497","notice_type":"k","base_type":"k","posted":"2026-06-24","posted_at":"2026-06-24T20:10:46.185Z","due_at":"2026-07-02T19:00:00Z","due_date":"2026-07-02","cancelled":false,"archived":true,"archive_date":"2026-08-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3bda2571f43c494eb3fbc14dc08da82a/view","enriched":true,"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}]},{"notice_id":"671f91f7e4ef4fcea3af0393944c1641","title":"J042--Door Inspections and Repair Service Contract","solicitation_number":"36C24126Q0497","notice_type":"k","base_type":"k","posted":"2026-09-09","posted_at":"2026-09-09T15:27:33.178Z","due_at":"2026-07-02T19:00:00Z","due_date":"2026-07-02","cancelled":false,"archived":true,"archive_date":"2026-10-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/671f91f7e4ef4fcea3af0393944c1641/view","enriched":true,"history":[{"index":8,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:42:36.910Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"cba945de8afb420794de453f0a427da0","solicitation_number":"36C24126P0643","related_opportunity_id":"671f91f7e4ef4fcea3af0393944c1641"},{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}]},{"notice_id":"cba945de8afb420794de453f0a427da0","title":"J042--Door Inspections and Repair Service Contract","solicitation_number":"36C24126P0643","notice_type":"a","base_type":"k","posted":"2026-09-09","posted_at":"2026-09-09T15:42:36.910Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-09","removed_at":null,"award_number":"36C24126P0643","awardee_name":"HurtVet Subcontracting, Inc.","amount":"981180.00","link_sam":"https://sam.gov/workspace/contract/opp/cba945de8afb420794de453f0a427da0/view","enriched":true,"history":[{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:42:36.910Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"cba945de8afb420794de453f0a427da0","solicitation_number":"36C24126P0643","related_opportunity_id":"671f91f7e4ef4fcea3af0393944c1641"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"}]}],"latest_notice_id":"cba945de8afb420794de453f0a427da0","first_type":"k","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-05-15","posted_at":"2026-05-15T17:51:55.672Z","created_at":"2026-05-15T17:48:32.713Z","modified_at":"2026-09-09T15:27:33.178Z","response_deadline":{"raw":"2026-06-04T17:00:00-04:00","utc":"2026-06-04T21:00:00Z","date":"2026-06-04","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0377e6b3fc0f495dae7a41080cc3aecb/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"J042--Door Inspections and Repair Service Contract","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-07-04","archive_type":"auto_custom"},"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}],"contacts":[{"name":"Shawn Lawrence","role":"primary","email":"Shawn.Lawrence@va.gov","phone":"203-932-5711","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"0377e6b3fc0f495dae7a41080cc3aecb","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"03798b450615493fb5e0d5943e679d8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T02:45:05.153276947Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"0fdac99bb4a1a1574af7ade513bc0aedef09bd651b8618cf4b2519c425a8c0e8","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T02:45:05.153276947Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"Combined Synopsis Solicitation\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01; March 13, 2026. The most recent Federal Acquisition Circular can be found at Acquisition.gov.\n\n\nThis solicitation is set-aside for SDVOSB\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 541350, with a small business size standard of $11.5 Million.\nThe FSC/PSC is J042.\n\nThe Manchester VA Medical Center 718 Smyth Road, Manchester, NH 03104 is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our main campus.\n\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nQuarterly Fire Door Inspections and Reports\n4\nQUARTERLY\n\n\n0002\nAnnual Fire Door Report\n`1\nYR\n\n\n0003\n Stand-By Service Call hours\n160\nHR\n\n\n0004\nMaterials and Parts\n1000\nDoors\n\n\n1001\nQuarterly Fire Door Inspections and Reports   Option Year 1\n4\nQUARTERLY\n\n\n1002\nAnnual Fire Door Report\n1\nYR\n\n\n1003\n Stand-By Service Call hours\n160\nHR\n\n\n1004\nMaterials and Parts\n1000\nDoors\n\n\n2001\nQuarterly Fire Door Inspections and Reports   Option Year 2\n4\nQUARTERLY\n\n\n2002\nAnnual Fire Door Report\n1\nYR\n\n\n2003\n Stand-By Service Call hours\n160\nHR\n\n\n2004\nMaterials and Parts\n1000\nDoors\n\n\n3001\nQuarterly Fire Door Inspections and Reports   Option Year 3\n4\nQUARTERLY\n\n\n3002\nAnnual Fire Door Report\n1\nYR\n\n\n3003\n Stand-By Service Call hours\n160\nHR\n\n\n3004\nMaterials and Parts\n1000\nDoors\n\n\n4001\nQuarterly Fire Door Inspections and Reports   Option Year 4\n4\nQUARTERLY\n\n\n4002\nAnnual Fire Door Report\n1\nYR\n\n\n4003\n Stand-By Service Call hours\n160\nHR\n\n\n4004\nMaterials and Parts\n1000\nDoors\n\n\n\n \nDEPARTMENT OF VETERANS AFFAIRS\nSTATEMENT OF WORK\nService Contract   Campus Wide Doors and Fire Door Inspections and Repairs\n\nINTRODUCTION\nThe VA Medical Center in Manchester is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our campus.  Service performance will be for the VAMC- Manchester at 718 Smyth Road, Manchester, NH 03104.   \n\nBACKGROUND\nVA Manchester s fire doors as well as non-fire doors have required inspections and maintenance on a periodic basis through the year.  The Facility Service, Maintenance Department, requires assistance in keeping up with required inspections and maintenance on the campus doors to ensure proper operations and prevent failure of the fire protection system.  Our current maintenance staff is shorthanded to ensure proper maintenance is being completed as well as responding to maintenance calls, performing regular duties, and handling the increase work order requests.  A service contract is needed to ensure the proper and timely execution of the required inspections and maintenance of the campus wide doors.   Contractor shall provide quarterly and annual inspections & reports as well as periodic maintenance to correct these deficiencies. The Campus contains approximately 1,000 doors which includes approximately 135 fire/smoke doors. \n\nThis is for a base plus 4 option year contract. \nSCOPE\nItem 1   Quarterly Fire Door Inspections \nThe contractor shall provide all personnel, equipment, tools vehicles, materials, supervision, and other items and services necessary to perform preventative maintenance, testing and repair tasks functions for the equipment described in the SOW.  \n\nContractor shall provide necessary parts and labor to perform regularly scheduled preventative maintenance (PM) services for approximately 135 Fire/Smoke door assemblies, based solely on current VAMC Manchester s life safety drawings, which are available to contract awardee, upon request. The drawings are to be used as a guide to aide in locating fire/smoke doors. Location of the doors that may not be identifiable on the drawings will be provided to contractor by VAMC Manchester.  No change order will be considered for credit or additional cost, unless there is more than a 10% variation from the above stated number of fire door assemblies.\n\nInspections and maintenance performed on fire door assemblies shall be in accordance with NFPA 80: Standard for Fire Doors and Other Opening Protectives, 2025 Edition - Chapter 5 Inspection, Testing, and Maintenance .  The Contractor shall also review, correct and prepare a full and accurate inventory list (excel format) of all known fire door assemblies as part of this solicitation. \n\nInspections on all 135 fire/smoke doors will be performed on a quarterly basis and include all components of fire door assemblies. All visits shall be scheduled and coordinated through the COR or designee during normal business hours.  Fire Door assembly Inspections / preventative maintenance shall include, but not be limited to the following:\n\nEnsure that all door assembly rating labels are intact and legible. \nEnsure glazing, vision light frames, and glazing beads are intact. \nEnsure door clearances around frames and at thresholds are appropriate.\nEnsure self-closure devices operate.\nConfirm that coordinators are installed with an inactive leaf closing before active leaf.\nEnsure latching hardware operates and secures the door when closed. Adjust as needed. \nEnsure auxiliary hardware does not interfere with operation of the door assembly.\nEnsure modifications to door assemblies do not void the labels.\nCheck gasket and edge seals and verify for presence and integrity.\n\nQuarterly Report\n\nQuarterly Report shall include the list of the fire/smoke doors, inspections performed and pass /fail on the inspections. These reports shall be delivered 14 calendar days after the date of the inspection. \n\nA cost estimate of the repairs required shall be provided for each failed item. These will be approved based on funding remaining in ITEM 3 & ITEM 4 (Labor hours and Parts).\n\nAfter Quarter 1, all other quarterly reports shall also include a list of corrections made since previous quarters report.\n\nCORRECTIONS/REPAIRS REQUIRED:  The Contractor shall immediately, but no later than 14 calendar days after discovery, notify the CO and COR (in writing) of the existence or the development of any defects in, or repairs required, to the fire door assemblies.  The Contractor shall furnish the CO and COR with a written estimate of the cost to make necessary repairs. (Repair costs shall be covered under Line item 3.3 Item 3 and 3.4 Item 4)\n\nThese items for repair may include some of the following:\n\nRepair or replacement of any device that does not operate as it should.\nProperly aligning doors, frames, hinges, hardware, and thresholds. \nReplacing any missing or broken parts.\nFilling and/ or repairing holes or breaks in door surfaces and frames.\n \n \nItem 2   Annual Report\nThe contractor shall provide the VA with an annual report on all fire door quarterly inspections and a wrap up of corrective actions. \nThis report shall include:\nFire door locations / labels and quarterly inspections (pass / fail). \nFire doors repairs by location \nType of failures (from highest quantity failure reason to lowest)\nOutstanding items to be repaired / replaced.\n\nItem 3- Stand-by Services (Labor)\nThe contractor shall provide on repair services to include labor costs for standby repair services related to repairs associated with doors across campus. These labor hours include labor hours associated with repairs to the fire/smoke door assemblies as well as hours associated with services requested for repair of non- fire/smoke doors.\nThese labor hours are not associated with the inspections and reporting labor hours. \nThe vendor will be able to schedule staffing within two (2) weeks of notification.  \nContractor shall provide 160 labor hours as specified under this line item.\n\nItem 4   Materials and Parts (Non-Routine Repairs and Maintenance)\nThe contractor shall supply parts and materials ($150 per door) for approximately 1,000 doors (inclusive of fire/smoke doors) as needed for necessary upgrades, replacement, and repairs.  If cost exceeds the agreed upon limitation ($150 per door), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 14 calendar days to the COR.    \nRepairs shall be commenced within 14 calendar days after the costs for repair has been agreed upon by the contractor or by the COR.  All repairs shall be in accordance with the manufacturer s requirements and\\or applicable laws, regulations, codes, etc.  All parts and materials shall be of the original manufacturer s design and specification, or equal thereto.  An extension may be granted at the discretion of the COR on a case by case basis.  Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible.\n\n\n\n\n\n\n\nPERFORMANCE REQUIREMENTS\nAll work shall be completed such that the integrity of the systems is maintained.  All work shall be done in accordance with OSHA, EPA regulations, NFPA codes, with particular attention to VA codes, Federal, State, and local regulations throughout the course of this service contract.\nThe Contractor shall submit technician certification/licensure prior to work start.  Copies of these are also to be submitted with the completed checklists.  \n\nThe contractor shall submit all necessary safety plans to include, but not limited to; equipment specific Lock-Out Tag Out procedures, Electrical Safety plan and SDS for any chemicals used to the COR for approval prior to working at the Medical Center.\n\nThe contractor shall schedule all site visits, to include emergencies, with the COR. \n\nThe contractor shall furnish authentic parts from the equipment manufacturer.  The determination of when to replace parts is at the recommendation of the technician, with the COR s concurrence.  Additional service charges may be incurred to install parts during scheduled inspections or callbacks as specified in this agreement.  \n\nThe contractor shall operate on the premises during the hours of 0700 and 1630, unless otherwise authorized by the COR. \n\nThe contractor shall respond within 4 hours for all emergency call backs.\n\nWork sites shall be left in the same manner of cleanliness and order in which they were found. Vendor will provide their own waste disposal, if any. \n\nAll vendor technicians performing work on site must report to Facility Service in Building 6 to the contractor badge check in/out room to sign in on the contractor log and get a  Contractor  badge. Badges must be returned, and log signed out prior to departing the premises.  Vendor shall then coordinate with the COR prior to performing their work.     \n\nPersonnel must wear the proper personal protective equipment (PPE) at all times.  Work done under this project must comply with infection control requirements. \n\nThe contractor shall receive all deliveries of materials, equipment, tools, or other goods off of station, and bring them to the job site.  The Manchester VA shall not accept deliveries for project purposes.  \n\nSpecial care will be taken to secure tools and construction equipment. \n\nMaterial Safety Data Sheets (MSDS s) must be submitted to the COR for approval for all hazardous materials before they are brought to the work site.  \n\nEnd of day cleanup of the work area(s) is mandatory, and all trash shall be bagged and properly disposed of offsite.  \n\nContractor vehicles, including those of their employees, are to be parked in the lower level of Lot D.   \n\nAll travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract.  Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc.\n\nDELIVERABLES\nContractor shall coordinate with the COR to provide a complete calendar year schedule for scheduled maintenance tasks at the commencement of the contract.\nContractor shall provide a prioritized phone support contact list at the commencement of the contract.\nSubmittal of proposed equipment and materials to be used on site for review and approval by the COR.\nSubmittal of Contractor safety plan and lock-out tag-out plan.\nSubmittal of Safety Data Sheets (SDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center.  Chemicals must be approved before they can be located on property.\n\nWithin two weeks of completing each visit, the vendor will provide a report on the following:\nThe final quarterly documentation report including but not limited to the following:  \nAll Fire and Smoke Door Assembly and Locations\nGeneral condition of each item repaired.\nDetailed written descriptions of repairs made. \nThis report shall include:\nName of the Contractor and Contract Number\nName of the Technician who performed services\nContractor service report.  \nService hours utilized.\nParts allowance utilized and itemized parts replaced.\nTotal cost of the visit\nIdentification of door assembly to be serviced.  (ID Number, Manufacturer's name, Fire door assembly, and any other Manufacturer's identification numbers.)\n\n6. 0 QUALIFICATIONS\nEach respondent must have an established business, with an office and full time staff.  The staff includes a \"fully qualified\" technician and a \"fully qualified\" technician who will serve as the backup.\n\"Fully Qualified\" is based upon training and on experience in the field.  For training, the technician(s) shall have successfully completed a formalized training program for the inspection, testing and maintenance of fire door assemblies, IAW the most recent edition of NFPA 80. \n\nThe technicians shall be authorized by the Contractor to perform the maintenance services.  All work shall be performed by \"Fully Qualified\" competent technicians.  The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved technician.  The CO may authenticate the training requirements, request training certificates or credentials from the Contractor at any time for any personnel who are servicing or installing any VAMC equipment.  The CO and/or COR specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on the VAMC equipment.\n\nThe Base contract period of performance is September 21, 2026 to September 20, 2027.\n\nOption Year 1: September 21, 2027 to September 20, 2028.\n\nOption Year 2: September 21, 2028 to September 20, 2029.\n\nOption Year 3: September 21, 2029 to September 20, 2030.\n\nOption Year 4: September 21, 2030 to September 20, 2031.\n\n\nPlaces of Performance\nAddress:\n718 Smyth Road\nManchester, NH\nPostal Code:\n03104\nCountry:\nUNITED STATES\n\n\n\nThe full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far. \n\nThe following solicitation provisions apply to this acquisition:\nFAR 52.212-1,  Instructions to Offerors Commercial Products and Commercial Services  (Sep 2023) (See Attachment 1).\nFAR 52.212-2 Evaluation-Commercial Products and Commercial Services: In accordance with RFO FAR 12.201-1 and FAR 12.201-2 when appropriate, the contracting officer may (1)Â Insert the provision atÂ 52.212-2, Evaluation-Commercial ProductsÂ andÂ Commercial Services, inÂ solicitationsÂ forÂ commercial productsÂ orÂ commercial services (See Attachment 2).\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/\n\n\n\nThe following contract clauses apply to this acquisition: \nFAR 52.212-4,  Contract Terms and Conditions Commercial Products and Commercial Services  (Nov 2023)\n\nFAR 52.222-90,  Addressing DEI Discrimination by Federal Contractors  (APR 2026)\nFAR 52.219-6,  Notice of Total Small Business Set-Aside  (Nov 2020)\nFAR 52.219-14,  Limitations on Subcontracting  (Oct 2022)\nFAR 52.217-8,  Option to Extend Services  (NOV 1999)\nFAR 52.217-9,  Option to Extend Term of the Contract  (MAR 2000)\nFAR 52.252-2,  Clauses Incorporated By Reference Â (Feb 1998)\nFAR 52.203 11, FAR 52.203 18, FAR 52.204 7, FAR 52.204 13, FAR 52.209 6, FAR 52.222 35, FAR 52.222 36, FAR 52.222 37, FAR 52.222 41, FAR 52.222 42, FAR 52.222 43, FAR 52.222 50, FAR 52.222 62, FAR 52.223 20, FAR 52.223 21, FAR 52.223 23, FAR 52.224 3, FAR 52.232 33, FAR 52.232 40, FAR 52.233 3, FAR 52.233 4, FAR 52.244 6, FAR 52.252 1\n\nVAAR 852.219-75,  limitations on Subcontracting  (NOV 2022).\nVAAR 852.232-72  Electronic Submission of Payment Requests  (NOV 2018)\nVAAR 852.204 70  Personal Identity Verification of Contractor Personnel  (MAY 2020)\nVAAR 852.204 72  Personnel Vetting and Credentialing  (FEB 2026)\nVAAR 852.201 70  Contracting Officer's Representative  (DEC 2022)\nVAAR 852.203 70  Commercial Advertising  (MAY 2018)\nVAAR 852.219-73  VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses  (JAN 2023) (DEVIATION)\n\n\n\n\n\n\nWage Determinations:\n\nThe following wage determination applies to this solicitation and is provided as Attachments (4 & 5):\n\nWage Determination 2015-4127 (Revision No.: 34)\nWage Determination 2015-4119 (Revision No.: 33)\n\n\n\nAll quoters shall submit the following: \n\nQuestions: Any questions must be submitted in writing no later than Wednesday 27 May 2026 at 5:00 PM EST. Answers to the questions will be posted by the following week. \n\nSite Visit information: Site visits will be held on Tuesday, 19 May 2026 at 11:00 AM EST located at the Manchester VAMC. Please contact Andrew Obrien directly (andrew.obrien@va.gov; (603) 624-4366) to schedule attendance at Manchester VAMC. Please note all questions must be submitted to Shawn Lawrence (Shawn.Lawrence@va.gov), prior to Wednesday 27 May 2026 at 5:00 PM EST. No questions will be answered at the site visit. \n\n\nQuote: Offeror shall provide a quote using the Line item table above. Offerors must also provide all applicable labor rates for the solicited services so they can be compared to the applicable wage determination for compliance with the Service Contract Labor Standards.\n\n\nAll quotes shall be sent to the Contract Specialist, Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12.\n\nComparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.   \n\n\nSubmission of your response shall be received not later than 4 June 2026 at 5:00:00 PM EST. All quotes shall be emailed to Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).  \n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. \nPoint of Contact: Shawn Lawrence, Shawn.Lawrence@va.gov.\n\nSee attached document: Attachment 1 Tailored FAR 52.212-1 Instructions to Offerors Commercial Products and Commercial Services.\nSee attached document: Attachment 2 Tailored 52.212-2 Evaluation - Commercial Products and Commercial Services.\nSee attached document: Attachment 3 852.219-75 Limitation on Subcontracting.\nSee attached document: Attachment 4 WD 2015-4119 Rev. 33.\nSee attached document: Attachment 5 WD 2015-4127 Rev. 34.\nSee attached document: Attachment 6 QASP.","text":"Combined Synopsis Solicitation\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01; March 13, 2026. The most recent Federal Acquisition Circular can be found at Acquisition.gov.\n\nThis solicitation is set-aside for SDVOSB\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 541350, with a small business size standard of $11.5 Million.\nThe FSC/PSC is J042.\n\nThe Manchester VA Medical Center 718 Smyth Road, Manchester, NH 03104 is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our main campus.\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nQuarterly Fire Door Inspections and Reports\n4\nQUARTERLY\n\n0002\nAnnual Fire Door Report\n`1\nYR\n\n0003\nStand-By Service Call hours\n160\nHR\n\n0004\nMaterials and Parts\n1000\nDoors\n\n1001\nQuarterly Fire Door Inspections and Reports Option Year 1\n4\nQUARTERLY\n\n1002\nAnnual Fire Door Report\n1\nYR\n\n1003\nStand-By Service Call hours\n160\nHR\n\n1004\nMaterials and Parts\n1000\nDoors\n\n2001\nQuarterly Fire Door Inspections and Reports Option Year 2\n4\nQUARTERLY\n\n2002\nAnnual Fire Door Report\n1\nYR\n\n2003\nStand-By Service Call hours\n160\nHR\n\n2004\nMaterials and Parts\n1000\nDoors\n\n3001\nQuarterly Fire Door Inspections and Reports Option Year 3\n4\nQUARTERLY\n\n3002\nAnnual Fire Door Report\n1\nYR\n\n3003\nStand-By Service Call hours\n160\nHR\n\n3004\nMaterials and Parts\n1000\nDoors\n\n4001\nQuarterly Fire Door Inspections and Reports Option Year 4\n4\nQUARTERLY\n\n4002\nAnnual Fire Door Report\n1\nYR\n\n4003\nStand-By Service Call hours\n160\nHR\n\n4004\nMaterials and Parts\n1000\nDoors\n\nDEPARTMENT OF VETERANS AFFAIRS\nSTATEMENT OF WORK\nService Contract Campus Wide Doors and Fire Door Inspections and Repairs\n\nINTRODUCTION\nThe VA Medical Center in Manchester is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our campus. Service performance will be for the VAMC- Manchester at 718 Smyth Road, Manchester, NH 03104.\n\nBACKGROUND\nVA Manchester s fire doors as well as non-fire doors have required inspections and maintenance on a periodic basis through the year. The Facility Service, Maintenance Department, requires assistance in keeping up with required inspections and maintenance on the campus doors to ensure proper operations and prevent failure of the fire protection system. Our current maintenance staff is shorthanded to ensure proper maintenance is being completed as well as responding to maintenance calls, performing regular duties, and handling the increase work order requests. A service contract is needed to ensure the proper and timely execution of the required inspections and maintenance of the campus wide doors. Contractor shall provide quarterly and annual inspections & reports as well as periodic maintenance to correct these deficiencies. The Campus contains approximately 1,000 doors which includes approximately 135 fire/smoke doors.\n\nThis is for a base plus 4 option year contract.\nSCOPE\nItem 1 Quarterly Fire Door Inspections\nThe contractor shall provide all personnel, equipment, tools vehicles, materials, supervision, and other items and services necessary to perform preventative maintenance, testing and repair tasks functions for the equipment described in the SOW.\n\nContractor shall provide necessary parts and labor to perform regularly scheduled preventative maintenance (PM) services for approximately 135 Fire/Smoke door assemblies, based solely on current VAMC Manchester s life safety drawings, which are available to contract awardee, upon request. The drawings are to be used as a guide to aide in locating fire/smoke doors. Location of the doors that may not be identifiable on the drawings will be provided to contractor by VAMC Manchester. No change order will be considered for credit or additional cost, unless there is more than a 10% variation from the above stated number of fire door assemblies.\n\nInspections and maintenance performed on fire door assemblies shall be in accordance with NFPA 80: Standard for Fire Doors and Other Opening Protectives, 2025 Edition - Chapter 5 Inspection, Testing, and Maintenance . The Contractor shall also review, correct and prepare a full and accurate inventory list (excel format) of all known fire door assemblies as part of this solicitation.\n\nInspections on all 135 fire/smoke doors will be performed on a quarterly basis and include all components of fire door assemblies. All visits shall be scheduled and coordinated through the COR or designee during normal business hours. Fire Door assembly Inspections / preventative maintenance shall include, but not be limited to the following:\n\nEnsure that all door assembly rating labels are intact and legible.\nEnsure glazing, vision light frames, and glazing beads are intact.\nEnsure door clearances around frames and at thresholds are appropriate.\nEnsure self-closure devices operate.\nConfirm that coordinators are installed with an inactive leaf closing before active leaf.\nEnsure latching hardware operates and secures the door when closed. Adjust as needed.\nEnsure auxiliary hardware does not interfere with operation of the door assembly.\nEnsure modifications to door assemblies do not void the labels.\nCheck gasket and edge seals and verify for presence and integrity.\n\nQuarterly Report\n\nQuarterly Report shall include the list of the fire/smoke doors, inspections performed and pass /fail on the inspections. These reports shall be delivered 14 calendar days after the date of the inspection.\n\nA cost estimate of the repairs required shall be provided for each failed item. These will be approved based on funding remaining in ITEM 3 & ITEM 4 (Labor hours and Parts).\n\nAfter Quarter 1, all other quarterly reports shall also include a list of corrections made since previous quarters report.\n\nCORRECTIONS/REPAIRS REQUIRED: The Contractor shall immediately, but no later than 14 calendar days after discovery, notify the CO and COR (in writing) of the existence or the development of any defects in, or repairs required, to the fire door assemblies. The Contractor shall furnish the CO and COR with a written estimate of the cost to make necessary repairs. (Repair costs shall be covered under Line item 3.3 Item 3 and 3.4 Item 4)\n\nThese items for repair may include some of the following:\n\nRepair or replacement of any device that does not operate as it should.\nProperly aligning doors, frames, hinges, hardware, and thresholds.\nReplacing any missing or broken parts.\nFilling and/ or repairing holes or breaks in door surfaces and frames.\n\nItem 2 Annual Report\nThe contractor shall provide the VA with an annual report on all fire door quarterly inspections and a wrap up of corrective actions.\nThis report shall include:\nFire door locations / labels and quarterly inspections (pass / fail).\nFire doors repairs by location\nType of failures (from highest quantity failure reason to lowest)\nOutstanding items to be repaired / replaced.\n\nItem 3- Stand-by Services (Labor)\nThe contractor shall provide on repair services to include labor costs for standby repair services related to repairs associated with doors across campus. These labor hours include labor hours associated with repairs to the fire/smoke door assemblies as well as hours associated with services requested for repair of non- fire/smoke doors.\nThese labor hours are not associated with the inspections and reporting labor hours.\nThe vendor will be able to schedule staffing within two (2) weeks of notification.\nContractor shall provide 160 labor hours as specified under this line item.\n\nItem 4 Materials and Parts (Non-Routine Repairs and Maintenance)\nThe contractor shall supply parts and materials ($150 per door) for approximately 1,000 doors (inclusive of fire/smoke doors) as needed for necessary upgrades, replacement, and repairs. If cost exceeds the agreed upon limitation ($150 per door), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 14 calendar days to the COR.\nRepairs shall be commenced within 14 calendar days after the costs for repair has been agreed upon by the contractor or by the COR. All repairs shall be in accordance with the manufacturer s requirements and\\or applicable laws, regulations, codes, etc. All parts and materials shall be of the original manufacturer s design and specification, or equal thereto. An extension may be granted at the discretion of the COR on a case by case basis. Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible.\n\nPERFORMANCE REQUIREMENTS\nAll work shall be completed such that the integrity of the systems is maintained. All work shall be done in accordance with OSHA, EPA regulations, NFPA codes, with particular attention to VA codes, Federal, State, and local regulations throughout the course of this service contract.\nThe Contractor shall submit technician certification/licensure prior to work start. Copies of these are also to be submitted with the completed checklists.\n\nThe contractor shall submit all necessary safety plans to include, but not limited to; equipment specific Lock-Out Tag Out procedures, Electrical Safety plan and SDS for any chemicals used to the COR for approval prior to working at the Medical Center.\n\nThe contractor shall schedule all site visits, to include emergencies, with the COR.\n\nThe contractor shall furnish authentic parts from the equipment manufacturer. The determination of when to replace parts is at the recommendation of the technician, with the COR s concurrence. Additional service charges may be incurred to install parts during scheduled inspections or callbacks as specified in this agreement.\n\nThe contractor shall operate on the premises during the hours of 0700 and 1630, unless otherwise authorized by the COR.\n\nThe contractor shall respond within 4 hours for all emergency call backs.\n\nWork sites shall be left in the same manner of cleanliness and order in which they were found. Vendor will provide their own waste disposal, if any.\n\nAll vendor technicians performing work on site must report to Facility Service in Building 6 to the contractor badge check in/out room to sign in on the contractor log and get a Contractor badge. Badges must be returned, and log signed out prior to departing the premises. Vendor shall then coordinate with the COR prior to performing their work.\n\nPersonnel must wear the proper personal protective equipment (PPE) at all times. Work done under this project must comply with infection control requirements.\n\nThe contractor shall receive all deliveries of materials, equipment, tools, or other goods off of station, and bring them to the job site. The Manchester VA shall not accept deliveries for project purposes.\n\nSpecial care will be taken to secure tools and construction equipment.\n\nMaterial Safety Data Sheets (MSDS s) must be submitted to the COR for approval for all hazardous materials before they are brought to the work site.\n\nEnd of day cleanup of the work area(s) is mandatory, and all trash shall be bagged and properly disposed of offsite.\n\nContractor vehicles, including those of their employees, are to be parked in the lower level of Lot D.\n\nAll travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract. Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc.\n\nDELIVERABLES\nContractor shall coordinate with the COR to provide a complete calendar year schedule for scheduled maintenance tasks at the commencement of the contract.\nContractor shall provide a prioritized phone support contact list at the commencement of the contract.\nSubmittal of proposed equipment and materials to be used on site for review and approval by the COR.\nSubmittal of Contractor safety plan and lock-out tag-out plan.\nSubmittal of Safety Data Sheets (SDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center. Chemicals must be approved before they can be located on property.\n\nWithin two weeks of completing each visit, the vendor will provide a report on the following:\nThe final quarterly documentation report including but not limited to the following:\nAll Fire and Smoke Door Assembly and Locations\nGeneral condition of each item repaired.\nDetailed written descriptions of repairs made.\nThis report shall include:\nName of the Contractor and Contract Number\nName of the Technician who performed services\nContractor service report.\nService hours utilized.\nParts allowance utilized and itemized parts replaced.\nTotal cost of the visit\nIdentification of door assembly to be serviced. (ID Number, Manufacturer's name, Fire door assembly, and any other Manufacturer's identification numbers.)\n\n6. 0 QUALIFICATIONS\nEach respondent must have an established business, with an office and full time staff. The staff includes a \"fully qualified\" technician and a \"fully qualified\" technician who will serve as the backup.\n\"Fully Qualified\" is based upon training and on experience in the field. For training, the technician(s) shall have successfully completed a formalized training program for the inspection, testing and maintenance of fire door assemblies, IAW the most recent edition of NFPA 80.\n\nThe technicians shall be authorized by the Contractor to perform the maintenance services. All work shall be performed by \"Fully Qualified\" competent technicians. The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved technician. The CO may authenticate the training requirements, request training certificates or credentials from the Contractor at any time for any personnel who are servicing or installing any VAMC equipment. The CO and/or COR specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on the VAMC equipment.\n\nThe Base contract period of performance is September 21, 2026 to September 20, 2027.\n\nOption Year 1: September 21, 2027 to September 20, 2028.\n\nOption Year 2: September 21, 2028 to September 20, 2029.\n\nOption Year 3: September 21, 2029 to September 20, 2030.\n\nOption Year 4: September 21, 2030 to September 20, 2031.\n\nPlaces of Performance\nAddress:\n718 Smyth Road\nManchester, NH\nPostal Code:\n03104\nCountry:\nUNITED STATES\n\nThe full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far.\n\nThe following solicitation provisions apply to this acquisition:\nFAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services (Sep 2023) (See Attachment 1).\nFAR 52.212-2 Evaluation-Commercial Products and Commercial Services: In accordance with RFO FAR 12.201-1 and FAR 12.201-2 when appropriate, the contracting officer may (1)Â Insert the provision atÂ 52.212-2, Evaluation-Commercial ProductsÂ andÂ Commercial Services, inÂ solicitationsÂ forÂ commercial productsÂ orÂ commercial services (See Attachment 2).\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/\n\nThe following contract clauses apply to this acquisition:\nFAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (Nov 2023)\n\nFAR 52.222-90, Addressing DEI Discrimination by Federal Contractors (APR 2026)\nFAR 52.219-6, Notice of Total Small Business Set-Aside (Nov 2020)\nFAR 52.219-14, Limitations on Subcontracting (Oct 2022)\nFAR 52.217-8, Option to Extend Services (NOV 1999)\nFAR 52.217-9, Option to Extend Term of the Contract (MAR 2000)\nFAR 52.252-2, Clauses Incorporated By Reference Â (Feb 1998)\nFAR 52.203 11, FAR 52.203 18, FAR 52.204 7, FAR 52.204 13, FAR 52.209 6, FAR 52.222 35, FAR 52.222 36, FAR 52.222 37, FAR 52.222 41, FAR 52.222 42, FAR 52.222 43, FAR 52.222 50, FAR 52.222 62, FAR 52.223 20, FAR 52.223 21, FAR 52.223 23, FAR 52.224 3, FAR 52.232 33, FAR 52.232 40, FAR 52.233 3, FAR 52.233 4, FAR 52.244 6, FAR 52.252 1\n\nVAAR 852.219-75, limitations on Subcontracting (NOV 2022).\nVAAR 852.232-72 Electronic Submission of Payment Requests (NOV 2018)\nVAAR 852.204 70 Personal Identity Verification of Contractor Personnel (MAY 2020)\nVAAR 852.204 72 Personnel Vetting and Credentialing (FEB 2026)\nVAAR 852.201 70 Contracting Officer's Representative (DEC 2022)\nVAAR 852.203 70 Commercial Advertising (MAY 2018)\nVAAR 852.219-73 VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses (JAN 2023) (DEVIATION)\n\nWage Determinations:\n\nThe following wage determination applies to this solicitation and is provided as Attachments (4 & 5):\n\nWage Determination 2015-4127 (Revision No.: 34)\nWage Determination 2015-4119 (Revision No.: 33)\n\nAll quoters shall submit the following:\n\nQuestions: Any questions must be submitted in writing no later than Wednesday 27 May 2026 at 5:00 PM EST. Answers to the questions will be posted by the following week.\n\nSite Visit information: Site visits will be held on Tuesday, 19 May 2026 at 11:00 AM EST located at the Manchester VAMC. Please contact Andrew Obrien directly (andrew.obrien@va.gov; (603) 624-4366) to schedule attendance at Manchester VAMC. Please note all questions must be submitted to Shawn Lawrence (Shawn.Lawrence@va.gov), prior to Wednesday 27 May 2026 at 5:00 PM EST. No questions will be answered at the site visit.\n\nQuote: Offeror shall provide a quote using the Line item table above. Offerors must also provide all applicable labor rates for the solicited services so they can be compared to the applicable wage determination for compliance with the Service Contract Labor Standards.\n\nAll quotes shall be sent to the Contract Specialist, Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12.\n\nComparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.\n\nSubmission of your response shall be received not later than 4 June 2026 at 5:00:00 PM EST. All quotes shall be emailed to Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.\nPoint of Contact: Shawn Lawrence, Shawn.Lawrence@va.gov.\n\nSee attached document: Attachment 1 Tailored FAR 52.212-1 Instructions to Offerors Commercial Products and Commercial Services.\nSee attached document: Attachment 2 Tailored 52.212-2 Evaluation - Commercial Products and Commercial Services.\nSee attached document: Attachment 3 852.219-75 Limitation on Subcontracting.\nSee attached document: Attachment 4 WD 2015-4119 Rev. 33.\nSee attached document: Attachment 5 WD 2015-4127 Rev. 34.\nSee attached document: Attachment 6 QASP.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24126Q0497","place_of_performance":{"zip":"03104","city":{"code":"45140","name":"Manchester"},"state":{"code":"NH","name":"New Hampshire"},"street":"Manchester VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"718 Smyth Road"},"product_service_code":"J042"},{"award":{"awardee":{}},"dates":{"posted":"2026-05-15","posted_at":"2026-05-15T17:39:11.402Z","created_at":"2026-05-15T17:39:02.608Z","modified_at":"2026-09-09T15:27:33.178Z","response_deadline":{"raw":"2026-06-04T17:00:00-04:00","utc":"2026-06-04T21:00:00Z","date":"2026-06-04","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/03798b450615493fb5e0d5943e679d8c/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"J042--Door Inspections and Repair Service Contract","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-07-04","archive_type":"auto_custom"},"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}],"contacts":[{"name":"Shawn Lawrence","role":"primary","email":"Shawn.Lawrence@va.gov","phone":"203-932-5711","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"03798b450615493fb5e0d5943e679d8c","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"03798b450615493fb5e0d5943e679d8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T02:45:05.653596962Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"6184dbbbbf47a27c9090052416cfc31f55faba3b5f12bf9bb35662389931c05e","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T02:45:05.653596962Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"Combined Synopsis Solicitation\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01; March 13, 2026. The most recent Federal Acquisition Circular can be found at Acquisition.gov.\n\n\nThis solicitation is set-aside for SDVOSB\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 541350, with a small business size standard of $11.5 Million.\nThe FSC/PSC is J042.\n\nThe Manchester VA Medical Center 718 Smyth Road, Manchester, NH 03104 is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our main campus.\n\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nQuarterly Fire Door Inspections and Reports\n4\nQUARTERLY\n\n\n0002\nAnnual Fire Door Report\n`1\nYR\n\n\n0003\n Stand-By Service Call hours\n160\nHR\n\n\n0004\nMaterials and Parts\n1000\nDoors\n\n\n1001\nQuarterly Fire Door Inspections and Reports   Option Year 1\n4\nQUARTERLY\n\n\n1002\nAnnual Fire Door Report\n1\nYR\n\n\n1003\n Stand-By Service Call hours\n160\nHR\n\n\n1004\nMaterials and Parts\n1000\nDoors\n\n\n2001\nQuarterly Fire Door Inspections and Reports   Option Year 2\n4\nQUARTERLY\n\n\n2002\nAnnual Fire Door Report\n1\nYR\n\n\n2003\n Stand-By Service Call hours\n160\nHR\n\n\n2004\nMaterials and Parts\n1000\nDoors\n\n\n3001\nQuarterly Fire Door Inspections and Reports   Option Year 3\n4\nQUARTERLY\n\n\n3002\nAnnual Fire Door Report\n1\nYR\n\n\n3003\n Stand-By Service Call hours\n160\nHR\n\n\n3004\nMaterials and Parts\n1000\nDoors\n\n\n4001\nQuarterly Fire Door Inspections and Reports   Option Year 4\n4\nQUARTERLY\n\n\n4002\nAnnual Fire Door Report\n1\nYR\n\n\n4003\n Stand-By Service Call hours\n160\nHR\n\n\n4004\nMaterials and Parts\n1000\nDoors\n\n\n\n \nDEPARTMENT OF VETERANS AFFAIRS\nSTATEMENT OF WORK\nService Contract   Campus Wide Doors and Fire Door Inspections and Repairs\n\nINTRODUCTION\nThe VA Medical Center in Manchester is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our campus.  Service performance will be for the VAMC- Manchester at 718 Smyth Road, Manchester, NH 03104.   \n\nBACKGROUND\nVA Manchester s fire doors as well as non-fire doors have required inspections and maintenance on a periodic basis through the year.  The Facility Service, Maintenance Department, requires assistance in keeping up with required inspections and maintenance on the campus doors to ensure proper operations and prevent failure of the fire protection system.  Our current maintenance staff is shorthanded to ensure proper maintenance is being completed as well as responding to maintenance calls, performing regular duties, and handling the increase work order requests.  A service contract is needed to ensure the proper and timely execution of the required inspections and maintenance of the campus wide doors.   Contractor shall provide quarterly and annual inspections & reports as well as periodic maintenance to correct these deficiencies. The Campus contains approximately 1,000 doors which includes approximately 135 fire/smoke doors. \n\nThis is for a base plus 4 option year contract. \nSCOPE\nItem 1   Quarterly Fire Door Inspections \nThe contractor shall provide all personnel, equipment, tools vehicles, materials, supervision, and other items and services necessary to perform preventative maintenance, testing and repair tasks functions for the equipment described in the SOW.  \n\nContractor shall provide necessary parts and labor to perform regularly scheduled preventative maintenance (PM) services for approximately 135 Fire/Smoke door assemblies, based solely on current VAMC Manchester s life safety drawings, which are available to contract awardee, upon request. The drawings are to be used as a guide to aide in locating fire/smoke doors. Location of the doors that may not be identifiable on the drawings will be provided to contractor by VAMC Manchester.  No change order will be considered for credit or additional cost, unless there is more than a 10% variation from the above stated number of fire door assemblies.\n\nInspections and maintenance performed on fire door assemblies shall be in accordance with NFPA 80: Standard for Fire Doors and Other Opening Protectives, 2025 Edition - Chapter 5 Inspection, Testing, and Maintenance .  The Contractor shall also review, correct and prepare a full and accurate inventory list (excel format) of all known fire door assemblies as part of this solicitation. \n\nInspections on all 135 fire/smoke doors will be performed on a quarterly basis and include all components of fire door assemblies. All visits shall be scheduled and coordinated through the COR or designee during normal business hours.  Fire Door assembly Inspections / preventative maintenance shall include, but not be limited to the following:\n\nEnsure that all door assembly rating labels are intact and legible. \nEnsure glazing, vision light frames, and glazing beads are intact. \nEnsure door clearances around frames and at thresholds are appropriate.\nEnsure self-closure devices operate.\nConfirm that coordinators are installed with an inactive leaf closing before active leaf.\nEnsure latching hardware operates and secures the door when closed. Adjust as needed. \nEnsure auxiliary hardware does not interfere with operation of the door assembly.\nEnsure modifications to door assemblies do not void the labels.\nCheck gasket and edge seals and verify for presence and integrity.\n\nQuarterly Report\n\nQuarterly Report shall include the list of the fire/smoke doors, inspections performed and pass /fail on the inspections. These reports shall be delivered 14 calendar days after the date of the inspection. \n\nA cost estimate of the repairs required shall be provided for each failed item. These will be approved based on funding remaining in ITEM 3 & ITEM 4 (Labor hours and Parts).\n\nAfter Quarter 1, all other quarterly reports shall also include a list of corrections made since previous quarters report.\n\nCORRECTIONS/REPAIRS REQUIRED:  The Contractor shall immediately, but no later than 14 calendar days after discovery, notify the CO and COR (in writing) of the existence or the development of any defects in, or repairs required, to the fire door assemblies.  The Contractor shall furnish the CO and COR with a written estimate of the cost to make necessary repairs. (Repair costs shall be covered under Line item 3.3 Item 3 and 3.4 Item 4)\n\nThese items for repair may include some of the following:\n\nRepair or replacement of any device that does not operate as it should.\nProperly aligning doors, frames, hinges, hardware, and thresholds. \nReplacing any missing or broken parts.\nFilling and/ or repairing holes or breaks in door surfaces and frames.\n \n \nItem 2   Annual Report\nThe contractor shall provide the VA with an annual report on all fire door quarterly inspections and a wrap up of corrective actions. \nThis report shall include:\nFire door locations / labels and quarterly inspections (pass / fail). \nFire doors repairs by location \nType of failures (from highest quantity failure reason to lowest)\nOutstanding items to be repaired / replaced.\n\nItem 3- Stand-by Services (Labor)\nThe contractor shall provide on repair services to include labor costs for standby repair services related to repairs associated with doors across campus. These labor hours include labor hours associated with repairs to the fire/smoke door assemblies as well as hours associated with services requested for repair of non- fire/smoke doors.\nThese labor hours are not associated with the inspections and reporting labor hours. \nThe vendor will be able to schedule staffing within two (2) weeks of notification.  \nContractor shall provide 160 labor hours as specified under this line item.\n\nItem 4   Materials and Parts (Non-Routine Repairs and Maintenance)\nThe contractor shall supply parts and materials ($150 per door) for approximately 1,000 doors (inclusive of fire/smoke doors) as needed for necessary upgrades, replacement, and repairs.  If cost exceeds the agreed upon limitation ($150 per door), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 14 calendar days to the COR.    \nRepairs shall be commenced within 14 calendar days after the costs for repair has been agreed upon by the contractor or by the COR.  All repairs shall be in accordance with the manufacturer s requirements and\\or applicable laws, regulations, codes, etc.  All parts and materials shall be of the original manufacturer s design and specification, or equal thereto.  An extension may be granted at the discretion of the COR on a case by case basis.  Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible.\n\n\n\n\n\n\n\nPERFORMANCE REQUIREMENTS\nAll work shall be completed such that the integrity of the systems is maintained.  All work shall be done in accordance with OSHA, EPA regulations, NFPA codes, with particular attention to VA codes, Federal, State, and local regulations throughout the course of this service contract.\nThe Contractor shall submit technician certification/licensure prior to work start.  Copies of these are also to be submitted with the completed checklists.  \n\nThe contractor shall submit all necessary safety plans to include, but not limited to; equipment specific Lock-Out Tag Out procedures, Electrical Safety plan and SDS for any chemicals used to the COR for approval prior to working at the Medical Center.\n\nThe contractor shall schedule all site visits, to include emergencies, with the COR. \n\nThe contractor shall furnish authentic parts from the equipment manufacturer.  The determination of when to replace parts is at the recommendation of the technician, with the COR s concurrence.  Additional service charges may be incurred to install parts during scheduled inspections or callbacks as specified in this agreement.  \n\nThe contractor shall operate on the premises during the hours of 0700 and 1630, unless otherwise authorized by the COR. \n\nThe contractor shall respond within 4 hours for all emergency call backs.\n\nWork sites shall be left in the same manner of cleanliness and order in which they were found. Vendor will provide their own waste disposal, if any. \n\nAll vendor technicians performing work on site must report to Facility Service in Building 6 to the contractor badge check in/out room to sign in on the contractor log and get a  Contractor  badge. Badges must be returned, and log signed out prior to departing the premises.  Vendor shall then coordinate with the COR prior to performing their work.     \n\nPersonnel must wear the proper personal protective equipment (PPE) at all times.  Work done under this project must comply with infection control requirements. \n\nThe contractor shall receive all deliveries of materials, equipment, tools, or other goods off of station, and bring them to the job site.  The Manchester VA shall not accept deliveries for project purposes.  \n\nSpecial care will be taken to secure tools and construction equipment. \n\nMaterial Safety Data Sheets (MSDS s) must be submitted to the COR for approval for all hazardous materials before they are brought to the work site.  \n\nEnd of day cleanup of the work area(s) is mandatory, and all trash shall be bagged and properly disposed of offsite.  \n\nContractor vehicles, including those of their employees, are to be parked in the lower level of Lot D.   \n\nAll travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract.  Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc.\n\nDELIVERABLES\nContractor shall coordinate with the COR to provide a complete calendar year schedule for scheduled maintenance tasks at the commencement of the contract.\nContractor shall provide a prioritized phone support contact list at the commencement of the contract.\nSubmittal of proposed equipment and materials to be used on site for review and approval by the COR.\nSubmittal of Contractor safety plan and lock-out tag-out plan.\nSubmittal of Safety Data Sheets (SDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center.  Chemicals must be approved before they can be located on property.\n\nWithin two weeks of completing each visit, the vendor will provide a report on the following:\nThe final quarterly documentation report including but not limited to the following:  \nAll Fire and Smoke Door Assembly and Locations\nGeneral condition of each item repaired.\nDetailed written descriptions of repairs made. \nThis report shall include:\nName of the Contractor and Contract Number\nName of the Technician who performed services\nContractor service report.  \nService hours utilized.\nParts allowance utilized and itemized parts replaced.\nTotal cost of the visit\nIdentification of door assembly to be serviced.  (ID Number, Manufacturer's name, Fire door assembly, and any other Manufacturer's identification numbers.)\n\n6. 0 QUALIFICATIONS\nEach respondent must have an established business, with an office and full time staff.  The staff includes a \"fully qualified\" technician and a \"fully qualified\" technician who will serve as the backup.\n\"Fully Qualified\" is based upon training and on experience in the field.  For training, the technician(s) shall have successfully completed a formalized training program for the inspection, testing and maintenance of fire door assemblies, IAW the most recent edition of NFPA 80. \n\nThe technicians shall be authorized by the Contractor to perform the maintenance services.  All work shall be performed by \"Fully Qualified\" competent technicians.  The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved technician.  The CO may authenticate the training requirements, request training certificates or credentials from the Contractor at any time for any personnel who are servicing or installing any VAMC equipment.  The CO and/or COR specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on the VAMC equipment.\n\nThe Base contract period of performance is September 21, 2026 to September 20, 2027.\n\nOption Year 1: September 21, 2027 to September 20, 2028.\n\nOption Year 2: September 21, 2028 to September 20, 2029.\n\nOption Year 3: September 21, 2029 to September 20, 2030.\n\nOption Year 4: September 21, 2030 to September 20, 2031.\n\n\nPlaces of Performance\nAddress:\n718 Smyth Road\nManchester, NH\nPostal Code:\n03104\nCountry:\nUNITED STATES\n\n\n\nThe full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far. \n\nThe following solicitation provisions apply to this acquisition:\nFAR 52.212-1,  Instructions to Offerors Commercial Products and Commercial Services  (Sep 2023) (See Attachment 1).\nFAR 52.212-2 Evaluation-Commercial Products and Commercial Services: In accordance with RFO FAR 12.201-1 and FAR 12.201-2 when appropriate, the contracting officer may (1)Â Insert the provision atÂ 52.212-2, Evaluation-Commercial ProductsÂ andÂ Commercial Services, inÂ solicitationsÂ forÂ commercial productsÂ orÂ commercial services (See Attachment 2).\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/\n\n\n\nThe following contract clauses apply to this acquisition: \nFAR 52.212-4,  Contract Terms and Conditions Commercial Products and Commercial Services  (Nov 2023)\n\nFAR 52.222-90,  Addressing DEI Discrimination by Federal Contractors  (APR 2026)\nFAR 52.219-6,  Notice of Total Small Business Set-Aside  (Nov 2020)\nFAR 52.219-14,  Limitations on Subcontracting  (Oct 2022)\nFAR 52.217-8,  Option to Extend Services  (NOV 1999)\nFAR 52.217-9,  Option to Extend Term of the Contract  (MAR 2000)\nFAR 52.252-2,  Clauses Incorporated By Reference Â (Feb 1998)\nFAR 52.203 11, FAR 52.203 18, FAR 52.204 7, FAR 52.204 13, FAR 52.209 6, FAR 52.222 35, FAR 52.222 36, FAR 52.222 37, FAR 52.222 41, FAR 52.222 42, FAR 52.222 43, FAR 52.222 50, FAR 52.222 62, FAR 52.223 20, FAR 52.223 21, FAR 52.223 23, FAR 52.224 3, FAR 52.232 33, FAR 52.232 40, FAR 52.233 3, FAR 52.233 4, FAR 52.244 6, FAR 52.252 1\n\nVAAR 852.219-75,  limitations on Subcontracting  (NOV 2022).\nVAAR 852.232-72  Electronic Submission of Payment Requests  (NOV 2018)\nVAAR 852.204 70  Personal Identity Verification of Contractor Personnel  (MAY 2020)\nVAAR 852.204 72  Personnel Vetting and Credentialing  (FEB 2026)\nVAAR 852.201 70  Contracting Officer's Representative  (DEC 2022)\nVAAR 852.203 70  Commercial Advertising  (MAY 2018)\nVAAR 852.219-73  VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses  (JAN 2023) (DEVIATION)\n\n\n\n\n\n\nWage Determinations:\n\nThe following wage determination applies to this solicitation and is provided as Attachments (4 & 5):\n\nWage Determination 2015-4127 (Revision No.: 34)\nWage Determination 2015-4119 (Revision No.: 33)\n\n\n\nAll quoters shall submit the following: \n\nQuestions: Any questions must be submitted in writing no later than Wednesday 27 May 2026 at 5:00 PM EST. Answers to the questions will be posted by the following week. \n\nSite Visit information: Site visits will be held on Tuesday, 19 May 2026 at 11:00 AM EST located at the Manchester VAMC. Please contact Andrew Obrien directly (andrew.obrien@va.gov; (603) 624-4366) to schedule attendance at Manchester VAMC. Please note all questions must be submitted to Shawn Lawrence (Shawn.Lawrence@va.gov), prior to Wednesday 27 May 2026 at 5:00 PM EST. No questions will be answered at the site visit. \n\n\nQuote: Offeror shall provide a quote using the Line item table above. Offerors must also provide all applicable labor rates for the solicited services so they can be compared to the applicable wage determination for compliance with the Service Contract Labor Standards.\n\n\nAll quotes shall be sent to the Contract Specialist, Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12.\n\nComparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.   \n\n\nSubmission of your response shall be received not later than 4 June 2026 at 5:00:00 PM EST. All quotes shall be emailed to Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).  \n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. \nPoint of Contact: Shawn Lawrence, Shawn.Lawrence@va.gov.\n\nSee attached document: Attachment 1 Tailored FAR 52.212-1 Instructions to Offerors Commercial Products and Commercial Services.\nSee attached document: Attachment 2 Tailored 52.212-2 Evaluation - Commercial Products and Commercial Services.\nSee attached document: Attachment 3 852.219-75 Limitation on Subcontracting.\nSee attached document: Attachment 4 WD 2015-4119 Rev. 33.\nSee attached document: Attachment 5 WD 2015-4127 Rev. 34.\nSee attached document: Attachment 6 QASP.","text":"Combined Synopsis Solicitation\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01; March 13, 2026. The most recent Federal Acquisition Circular can be found at Acquisition.gov.\n\nThis solicitation is set-aside for SDVOSB\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 541350, with a small business size standard of $11.5 Million.\nThe FSC/PSC is J042.\n\nThe Manchester VA Medical Center 718 Smyth Road, Manchester, NH 03104 is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our main campus.\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nQuarterly Fire Door Inspections and Reports\n4\nQUARTERLY\n\n0002\nAnnual Fire Door Report\n`1\nYR\n\n0003\nStand-By Service Call hours\n160\nHR\n\n0004\nMaterials and Parts\n1000\nDoors\n\n1001\nQuarterly Fire Door Inspections and Reports Option Year 1\n4\nQUARTERLY\n\n1002\nAnnual Fire Door Report\n1\nYR\n\n1003\nStand-By Service Call hours\n160\nHR\n\n1004\nMaterials and Parts\n1000\nDoors\n\n2001\nQuarterly Fire Door Inspections and Reports Option Year 2\n4\nQUARTERLY\n\n2002\nAnnual Fire Door Report\n1\nYR\n\n2003\nStand-By Service Call hours\n160\nHR\n\n2004\nMaterials and Parts\n1000\nDoors\n\n3001\nQuarterly Fire Door Inspections and Reports Option Year 3\n4\nQUARTERLY\n\n3002\nAnnual Fire Door Report\n1\nYR\n\n3003\nStand-By Service Call hours\n160\nHR\n\n3004\nMaterials and Parts\n1000\nDoors\n\n4001\nQuarterly Fire Door Inspections and Reports Option Year 4\n4\nQUARTERLY\n\n4002\nAnnual Fire Door Report\n1\nYR\n\n4003\nStand-By Service Call hours\n160\nHR\n\n4004\nMaterials and Parts\n1000\nDoors\n\nDEPARTMENT OF VETERANS AFFAIRS\nSTATEMENT OF WORK\nService Contract Campus Wide Doors and Fire Door Inspections and Repairs\n\nINTRODUCTION\nThe VA Medical Center in Manchester is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our campus. Service performance will be for the VAMC- Manchester at 718 Smyth Road, Manchester, NH 03104.\n\nBACKGROUND\nVA Manchester s fire doors as well as non-fire doors have required inspections and maintenance on a periodic basis through the year. The Facility Service, Maintenance Department, requires assistance in keeping up with required inspections and maintenance on the campus doors to ensure proper operations and prevent failure of the fire protection system. Our current maintenance staff is shorthanded to ensure proper maintenance is being completed as well as responding to maintenance calls, performing regular duties, and handling the increase work order requests. A service contract is needed to ensure the proper and timely execution of the required inspections and maintenance of the campus wide doors. Contractor shall provide quarterly and annual inspections & reports as well as periodic maintenance to correct these deficiencies. The Campus contains approximately 1,000 doors which includes approximately 135 fire/smoke doors.\n\nThis is for a base plus 4 option year contract.\nSCOPE\nItem 1 Quarterly Fire Door Inspections\nThe contractor shall provide all personnel, equipment, tools vehicles, materials, supervision, and other items and services necessary to perform preventative maintenance, testing and repair tasks functions for the equipment described in the SOW.\n\nContractor shall provide necessary parts and labor to perform regularly scheduled preventative maintenance (PM) services for approximately 135 Fire/Smoke door assemblies, based solely on current VAMC Manchester s life safety drawings, which are available to contract awardee, upon request. The drawings are to be used as a guide to aide in locating fire/smoke doors. Location of the doors that may not be identifiable on the drawings will be provided to contractor by VAMC Manchester. No change order will be considered for credit or additional cost, unless there is more than a 10% variation from the above stated number of fire door assemblies.\n\nInspections and maintenance performed on fire door assemblies shall be in accordance with NFPA 80: Standard for Fire Doors and Other Opening Protectives, 2025 Edition - Chapter 5 Inspection, Testing, and Maintenance . The Contractor shall also review, correct and prepare a full and accurate inventory list (excel format) of all known fire door assemblies as part of this solicitation.\n\nInspections on all 135 fire/smoke doors will be performed on a quarterly basis and include all components of fire door assemblies. All visits shall be scheduled and coordinated through the COR or designee during normal business hours. Fire Door assembly Inspections / preventative maintenance shall include, but not be limited to the following:\n\nEnsure that all door assembly rating labels are intact and legible.\nEnsure glazing, vision light frames, and glazing beads are intact.\nEnsure door clearances around frames and at thresholds are appropriate.\nEnsure self-closure devices operate.\nConfirm that coordinators are installed with an inactive leaf closing before active leaf.\nEnsure latching hardware operates and secures the door when closed. Adjust as needed.\nEnsure auxiliary hardware does not interfere with operation of the door assembly.\nEnsure modifications to door assemblies do not void the labels.\nCheck gasket and edge seals and verify for presence and integrity.\n\nQuarterly Report\n\nQuarterly Report shall include the list of the fire/smoke doors, inspections performed and pass /fail on the inspections. These reports shall be delivered 14 calendar days after the date of the inspection.\n\nA cost estimate of the repairs required shall be provided for each failed item. These will be approved based on funding remaining in ITEM 3 & ITEM 4 (Labor hours and Parts).\n\nAfter Quarter 1, all other quarterly reports shall also include a list of corrections made since previous quarters report.\n\nCORRECTIONS/REPAIRS REQUIRED: The Contractor shall immediately, but no later than 14 calendar days after discovery, notify the CO and COR (in writing) of the existence or the development of any defects in, or repairs required, to the fire door assemblies. The Contractor shall furnish the CO and COR with a written estimate of the cost to make necessary repairs. (Repair costs shall be covered under Line item 3.3 Item 3 and 3.4 Item 4)\n\nThese items for repair may include some of the following:\n\nRepair or replacement of any device that does not operate as it should.\nProperly aligning doors, frames, hinges, hardware, and thresholds.\nReplacing any missing or broken parts.\nFilling and/ or repairing holes or breaks in door surfaces and frames.\n\nItem 2 Annual Report\nThe contractor shall provide the VA with an annual report on all fire door quarterly inspections and a wrap up of corrective actions.\nThis report shall include:\nFire door locations / labels and quarterly inspections (pass / fail).\nFire doors repairs by location\nType of failures (from highest quantity failure reason to lowest)\nOutstanding items to be repaired / replaced.\n\nItem 3- Stand-by Services (Labor)\nThe contractor shall provide on repair services to include labor costs for standby repair services related to repairs associated with doors across campus. These labor hours include labor hours associated with repairs to the fire/smoke door assemblies as well as hours associated with services requested for repair of non- fire/smoke doors.\nThese labor hours are not associated with the inspections and reporting labor hours.\nThe vendor will be able to schedule staffing within two (2) weeks of notification.\nContractor shall provide 160 labor hours as specified under this line item.\n\nItem 4 Materials and Parts (Non-Routine Repairs and Maintenance)\nThe contractor shall supply parts and materials ($150 per door) for approximately 1,000 doors (inclusive of fire/smoke doors) as needed for necessary upgrades, replacement, and repairs. If cost exceeds the agreed upon limitation ($150 per door), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 14 calendar days to the COR.\nRepairs shall be commenced within 14 calendar days after the costs for repair has been agreed upon by the contractor or by the COR. All repairs shall be in accordance with the manufacturer s requirements and\\or applicable laws, regulations, codes, etc. All parts and materials shall be of the original manufacturer s design and specification, or equal thereto. An extension may be granted at the discretion of the COR on a case by case basis. Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible.\n\nPERFORMANCE REQUIREMENTS\nAll work shall be completed such that the integrity of the systems is maintained. All work shall be done in accordance with OSHA, EPA regulations, NFPA codes, with particular attention to VA codes, Federal, State, and local regulations throughout the course of this service contract.\nThe Contractor shall submit technician certification/licensure prior to work start. Copies of these are also to be submitted with the completed checklists.\n\nThe contractor shall submit all necessary safety plans to include, but not limited to; equipment specific Lock-Out Tag Out procedures, Electrical Safety plan and SDS for any chemicals used to the COR for approval prior to working at the Medical Center.\n\nThe contractor shall schedule all site visits, to include emergencies, with the COR.\n\nThe contractor shall furnish authentic parts from the equipment manufacturer. The determination of when to replace parts is at the recommendation of the technician, with the COR s concurrence. Additional service charges may be incurred to install parts during scheduled inspections or callbacks as specified in this agreement.\n\nThe contractor shall operate on the premises during the hours of 0700 and 1630, unless otherwise authorized by the COR.\n\nThe contractor shall respond within 4 hours for all emergency call backs.\n\nWork sites shall be left in the same manner of cleanliness and order in which they were found. Vendor will provide their own waste disposal, if any.\n\nAll vendor technicians performing work on site must report to Facility Service in Building 6 to the contractor badge check in/out room to sign in on the contractor log and get a Contractor badge. Badges must be returned, and log signed out prior to departing the premises. Vendor shall then coordinate with the COR prior to performing their work.\n\nPersonnel must wear the proper personal protective equipment (PPE) at all times. Work done under this project must comply with infection control requirements.\n\nThe contractor shall receive all deliveries of materials, equipment, tools, or other goods off of station, and bring them to the job site. The Manchester VA shall not accept deliveries for project purposes.\n\nSpecial care will be taken to secure tools and construction equipment.\n\nMaterial Safety Data Sheets (MSDS s) must be submitted to the COR for approval for all hazardous materials before they are brought to the work site.\n\nEnd of day cleanup of the work area(s) is mandatory, and all trash shall be bagged and properly disposed of offsite.\n\nContractor vehicles, including those of their employees, are to be parked in the lower level of Lot D.\n\nAll travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract. Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc.\n\nDELIVERABLES\nContractor shall coordinate with the COR to provide a complete calendar year schedule for scheduled maintenance tasks at the commencement of the contract.\nContractor shall provide a prioritized phone support contact list at the commencement of the contract.\nSubmittal of proposed equipment and materials to be used on site for review and approval by the COR.\nSubmittal of Contractor safety plan and lock-out tag-out plan.\nSubmittal of Safety Data Sheets (SDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center. Chemicals must be approved before they can be located on property.\n\nWithin two weeks of completing each visit, the vendor will provide a report on the following:\nThe final quarterly documentation report including but not limited to the following:\nAll Fire and Smoke Door Assembly and Locations\nGeneral condition of each item repaired.\nDetailed written descriptions of repairs made.\nThis report shall include:\nName of the Contractor and Contract Number\nName of the Technician who performed services\nContractor service report.\nService hours utilized.\nParts allowance utilized and itemized parts replaced.\nTotal cost of the visit\nIdentification of door assembly to be serviced. (ID Number, Manufacturer's name, Fire door assembly, and any other Manufacturer's identification numbers.)\n\n6. 0 QUALIFICATIONS\nEach respondent must have an established business, with an office and full time staff. The staff includes a \"fully qualified\" technician and a \"fully qualified\" technician who will serve as the backup.\n\"Fully Qualified\" is based upon training and on experience in the field. For training, the technician(s) shall have successfully completed a formalized training program for the inspection, testing and maintenance of fire door assemblies, IAW the most recent edition of NFPA 80.\n\nThe technicians shall be authorized by the Contractor to perform the maintenance services. All work shall be performed by \"Fully Qualified\" competent technicians. The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved technician. The CO may authenticate the training requirements, request training certificates or credentials from the Contractor at any time for any personnel who are servicing or installing any VAMC equipment. The CO and/or COR specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on the VAMC equipment.\n\nThe Base contract period of performance is September 21, 2026 to September 20, 2027.\n\nOption Year 1: September 21, 2027 to September 20, 2028.\n\nOption Year 2: September 21, 2028 to September 20, 2029.\n\nOption Year 3: September 21, 2029 to September 20, 2030.\n\nOption Year 4: September 21, 2030 to September 20, 2031.\n\nPlaces of Performance\nAddress:\n718 Smyth Road\nManchester, NH\nPostal Code:\n03104\nCountry:\nUNITED STATES\n\nThe full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far.\n\nThe following solicitation provisions apply to this acquisition:\nFAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services (Sep 2023) (See Attachment 1).\nFAR 52.212-2 Evaluation-Commercial Products and Commercial Services: In accordance with RFO FAR 12.201-1 and FAR 12.201-2 when appropriate, the contracting officer may (1)Â Insert the provision atÂ 52.212-2, Evaluation-Commercial ProductsÂ andÂ Commercial Services, inÂ solicitationsÂ forÂ commercial productsÂ orÂ commercial services (See Attachment 2).\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/\n\nThe following contract clauses apply to this acquisition:\nFAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (Nov 2023)\n\nFAR 52.222-90, Addressing DEI Discrimination by Federal Contractors (APR 2026)\nFAR 52.219-6, Notice of Total Small Business Set-Aside (Nov 2020)\nFAR 52.219-14, Limitations on Subcontracting (Oct 2022)\nFAR 52.217-8, Option to Extend Services (NOV 1999)\nFAR 52.217-9, Option to Extend Term of the Contract (MAR 2000)\nFAR 52.252-2, Clauses Incorporated By Reference Â (Feb 1998)\nFAR 52.203 11, FAR 52.203 18, FAR 52.204 7, FAR 52.204 13, FAR 52.209 6, FAR 52.222 35, FAR 52.222 36, FAR 52.222 37, FAR 52.222 41, FAR 52.222 42, FAR 52.222 43, FAR 52.222 50, FAR 52.222 62, FAR 52.223 20, FAR 52.223 21, FAR 52.223 23, FAR 52.224 3, FAR 52.232 33, FAR 52.232 40, FAR 52.233 3, FAR 52.233 4, FAR 52.244 6, FAR 52.252 1\n\nVAAR 852.219-75, limitations on Subcontracting (NOV 2022).\nVAAR 852.232-72 Electronic Submission of Payment Requests (NOV 2018)\nVAAR 852.204 70 Personal Identity Verification of Contractor Personnel (MAY 2020)\nVAAR 852.204 72 Personnel Vetting and Credentialing (FEB 2026)\nVAAR 852.201 70 Contracting Officer's Representative (DEC 2022)\nVAAR 852.203 70 Commercial Advertising (MAY 2018)\nVAAR 852.219-73 VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses (JAN 2023) (DEVIATION)\n\nWage Determinations:\n\nThe following wage determination applies to this solicitation and is provided as Attachments (4 & 5):\n\nWage Determination 2015-4127 (Revision No.: 34)\nWage Determination 2015-4119 (Revision No.: 33)\n\nAll quoters shall submit the following:\n\nQuestions: Any questions must be submitted in writing no later than Wednesday 27 May 2026 at 5:00 PM EST. Answers to the questions will be posted by the following week.\n\nSite Visit information: Site visits will be held on Tuesday, 19 May 2026 at 11:00 AM EST located at the Manchester VAMC. Please contact Andrew Obrien directly (andrew.obrien@va.gov; (603) 624-4366) to schedule attendance at Manchester VAMC. Please note all questions must be submitted to Shawn Lawrence (Shawn.Lawrence@va.gov), prior to Wednesday 27 May 2026 at 5:00 PM EST. No questions will be answered at the site visit.\n\nQuote: Offeror shall provide a quote using the Line item table above. Offerors must also provide all applicable labor rates for the solicited services so they can be compared to the applicable wage determination for compliance with the Service Contract Labor Standards.\n\nAll quotes shall be sent to the Contract Specialist, Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12.\n\nComparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.\n\nSubmission of your response shall be received not later than 4 June 2026 at 5:00:00 PM EST. All quotes shall be emailed to Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.\nPoint of Contact: Shawn Lawrence, Shawn.Lawrence@va.gov.\n\nSee attached document: Attachment 1 Tailored FAR 52.212-1 Instructions to Offerors Commercial Products and Commercial Services.\nSee attached document: Attachment 2 Tailored 52.212-2 Evaluation - Commercial Products and Commercial Services.\nSee attached document: Attachment 3 852.219-75 Limitation on Subcontracting.\nSee attached document: Attachment 4 WD 2015-4119 Rev. 33.\nSee attached document: Attachment 5 WD 2015-4127 Rev. 34.\nSee attached document: Attachment 6 QASP.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24126Q0497","place_of_performance":{"zip":"03104","city":{"code":"45140","name":"Manchester"},"state":{"code":"NH","name":"New Hampshire"},"street":"Manchester VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"718 Smyth Road"},"product_service_code":"J042"},{"award":{"awardee":{}},"dates":{"posted":"2026-05-15","posted_at":"2026-05-15T17:55:15.034Z","created_at":"2026-05-15T17:53:47.696Z","modified_at":"2026-09-09T15:27:33.178Z","response_deadline":{"raw":"2026-06-04T17:00:00-04:00","utc":"2026-06-04T21:00:00Z","date":"2026-06-04","time":"17:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/03ffaa2252df43daa68090eaad34594e/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"J042--Door Inspections and Repair Service Contract","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-07-04","archive_type":"auto_custom"},"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}],"contacts":[{"name":"Shawn Lawrence","role":"primary","email":"Shawn.Lawrence@va.gov","phone":"203-932-5711","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"03ffaa2252df43daa68090eaad34594e","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"03798b450615493fb5e0d5943e679d8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-21T02:45:06.151718340Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T16:22:40.277975Z","row_sha256":"8f3800d023790956c65c34f743d652e3aff7c9d1c2bfb827f0f62289278756ce","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-21T02:45:06.151718340Z","first_seen_at":"2026-09-16T16:22:40.277975Z"},"description":{"html":"Combined Synopsis Solicitation\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01; March 13, 2026. The most recent Federal Acquisition Circular can be found at Acquisition.gov.\n\n\nThis solicitation is set-aside for SDVOSB\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 541350, with a small business size standard of $11.5 Million.\nThe FSC/PSC is J042.\n\nThe Manchester VA Medical Center 718 Smyth Road, Manchester, NH 03104 is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our main campus.\n\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nQuarterly Fire Door Inspections and Reports\n4\nQUARTERLY\n\n\n0002\nAnnual Fire Door Report\n`1\nYR\n\n\n0003\n Stand-By Service Call hours\n160\nHR\n\n\n0004\nMaterials and Parts\n1000\nDoors\n\n\n1001\nQuarterly Fire Door Inspections and Reports   Option Year 1\n4\nQUARTERLY\n\n\n1002\nAnnual Fire Door Report\n1\nYR\n\n\n1003\n Stand-By Service Call hours\n160\nHR\n\n\n1004\nMaterials and Parts\n1000\nDoors\n\n\n2001\nQuarterly Fire Door Inspections and Reports   Option Year 2\n4\nQUARTERLY\n\n\n2002\nAnnual Fire Door Report\n1\nYR\n\n\n2003\n Stand-By Service Call hours\n160\nHR\n\n\n2004\nMaterials and Parts\n1000\nDoors\n\n\n3001\nQuarterly Fire Door Inspections and Reports   Option Year 3\n4\nQUARTERLY\n\n\n3002\nAnnual Fire Door Report\n1\nYR\n\n\n3003\n Stand-By Service Call hours\n160\nHR\n\n\n3004\nMaterials and Parts\n1000\nDoors\n\n\n4001\nQuarterly Fire Door Inspections and Reports   Option Year 4\n4\nQUARTERLY\n\n\n4002\nAnnual Fire Door Report\n1\nYR\n\n\n4003\n Stand-By Service Call hours\n160\nHR\n\n\n4004\nMaterials and Parts\n1000\nDoors\n\n\n\n \nDEPARTMENT OF VETERANS AFFAIRS\nSTATEMENT OF WORK\nService Contract   Campus Wide Doors and Fire Door Inspections and Repairs\n\nINTRODUCTION\nThe VA Medical Center in Manchester is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our campus.  Service performance will be for the VAMC- Manchester at 718 Smyth Road, Manchester, NH 03104.   \n\nBACKGROUND\nVA Manchester s fire doors as well as non-fire doors have required inspections and maintenance on a periodic basis through the year.  The Facility Service, Maintenance Department, requires assistance in keeping up with required inspections and maintenance on the campus doors to ensure proper operations and prevent failure of the fire protection system.  Our current maintenance staff is shorthanded to ensure proper maintenance is being completed as well as responding to maintenance calls, performing regular duties, and handling the increase work order requests.  A service contract is needed to ensure the proper and timely execution of the required inspections and maintenance of the campus wide doors.   Contractor shall provide quarterly and annual inspections & reports as well as periodic maintenance to correct these deficiencies. The Campus contains approximately 1,000 doors which includes approximately 135 fire/smoke doors. \n\nThis is for a base plus 4 option year contract. \nSCOPE\nItem 1   Quarterly Fire Door Inspections \nThe contractor shall provide all personnel, equipment, tools vehicles, materials, supervision, and other items and services necessary to perform preventative maintenance, testing and repair tasks functions for the equipment described in the SOW.  \n\nContractor shall provide necessary parts and labor to perform regularly scheduled preventative maintenance (PM) services for approximately 135 Fire/Smoke door assemblies, based solely on current VAMC Manchester s life safety drawings, which are available to contract awardee, upon request. The drawings are to be used as a guide to aide in locating fire/smoke doors. Location of the doors that may not be identifiable on the drawings will be provided to contractor by VAMC Manchester.  No change order will be considered for credit or additional cost, unless there is more than a 10% variation from the above stated number of fire door assemblies.\n\nInspections and maintenance performed on fire door assemblies shall be in accordance with NFPA 80: Standard for Fire Doors and Other Opening Protectives, 2025 Edition - Chapter 5 Inspection, Testing, and Maintenance .  The Contractor shall also review, correct and prepare a full and accurate inventory list (excel format) of all known fire door assemblies as part of this solicitation. \n\nInspections on all 135 fire/smoke doors will be performed on a quarterly basis and include all components of fire door assemblies. All visits shall be scheduled and coordinated through the COR or designee during normal business hours.  Fire Door assembly Inspections / preventative maintenance shall include, but not be limited to the following:\n\nEnsure that all door assembly rating labels are intact and legible. \nEnsure glazing, vision light frames, and glazing beads are intact. \nEnsure door clearances around frames and at thresholds are appropriate.\nEnsure self-closure devices operate.\nConfirm that coordinators are installed with an inactive leaf closing before active leaf.\nEnsure latching hardware operates and secures the door when closed. Adjust as needed. \nEnsure auxiliary hardware does not interfere with operation of the door assembly.\nEnsure modifications to door assemblies do not void the labels.\nCheck gasket and edge seals and verify for presence and integrity.\n\nQuarterly Report\n\nQuarterly Report shall include the list of the fire/smoke doors, inspections performed and pass /fail on the inspections. These reports shall be delivered 14 calendar days after the date of the inspection. \n\nA cost estimate of the repairs required shall be provided for each failed item. These will be approved based on funding remaining in ITEM 3 & ITEM 4 (Labor hours and Parts).\n\nAfter Quarter 1, all other quarterly reports shall also include a list of corrections made since previous quarters report.\n\nCORRECTIONS/REPAIRS REQUIRED:  The Contractor shall immediately, but no later than 14 calendar days after discovery, notify the CO and COR (in writing) of the existence or the development of any defects in, or repairs required, to the fire door assemblies.  The Contractor shall furnish the CO and COR with a written estimate of the cost to make necessary repairs. (Repair costs shall be covered under Line item 3.3 Item 3 and 3.4 Item 4)\n\nThese items for repair may include some of the following:\n\nRepair or replacement of any device that does not operate as it should.\nProperly aligning doors, frames, hinges, hardware, and thresholds. \nReplacing any missing or broken parts.\nFilling and/ or repairing holes or breaks in door surfaces and frames.\n \n \nItem 2   Annual Report\nThe contractor shall provide the VA with an annual report on all fire door quarterly inspections and a wrap up of corrective actions. \nThis report shall include:\nFire door locations / labels and quarterly inspections (pass / fail). \nFire doors repairs by location \nType of failures (from highest quantity failure reason to lowest)\nOutstanding items to be repaired / replaced.\n\nItem 3- Stand-by Services (Labor)\nThe contractor shall provide on repair services to include labor costs for standby repair services related to repairs associated with doors across campus. These labor hours include labor hours associated with repairs to the fire/smoke door assemblies as well as hours associated with services requested for repair of non- fire/smoke doors.\nThese labor hours are not associated with the inspections and reporting labor hours. \nThe vendor will be able to schedule staffing within two (2) weeks of notification.  \nContractor shall provide 160 labor hours as specified under this line item.\n\nItem 4   Materials and Parts (Non-Routine Repairs and Maintenance)\nThe contractor shall supply parts and materials ($150 per door) for approximately 1,000 doors (inclusive of fire/smoke doors) as needed for necessary upgrades, replacement, and repairs.  If cost exceeds the agreed upon limitation ($150 per door), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 14 calendar days to the COR.    \nRepairs shall be commenced within 14 calendar days after the costs for repair has been agreed upon by the contractor or by the COR.  All repairs shall be in accordance with the manufacturer s requirements and\\or applicable laws, regulations, codes, etc.  All parts and materials shall be of the original manufacturer s design and specification, or equal thereto.  An extension may be granted at the discretion of the COR on a case by case basis.  Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible.\n\n\n\n\n\n\n\nPERFORMANCE REQUIREMENTS\nAll work shall be completed such that the integrity of the systems is maintained.  All work shall be done in accordance with OSHA, EPA regulations, NFPA codes, with particular attention to VA codes, Federal, State, and local regulations throughout the course of this service contract.\nThe Contractor shall submit technician certification/licensure prior to work start.  Copies of these are also to be submitted with the completed checklists.  \n\nThe contractor shall submit all necessary safety plans to include, but not limited to; equipment specific Lock-Out Tag Out procedures, Electrical Safety plan and SDS for any chemicals used to the COR for approval prior to working at the Medical Center.\n\nThe contractor shall schedule all site visits, to include emergencies, with the COR. \n\nThe contractor shall furnish authentic parts from the equipment manufacturer.  The determination of when to replace parts is at the recommendation of the technician, with the COR s concurrence.  Additional service charges may be incurred to install parts during scheduled inspections or callbacks as specified in this agreement.  \n\nThe contractor shall operate on the premises during the hours of 0700 and 1630, unless otherwise authorized by the COR. \n\nThe contractor shall respond within 4 hours for all emergency call backs.\n\nWork sites shall be left in the same manner of cleanliness and order in which they were found. Vendor will provide their own waste disposal, if any. \n\nAll vendor technicians performing work on site must report to Facility Service in Building 6 to the contractor badge check in/out room to sign in on the contractor log and get a  Contractor  badge. Badges must be returned, and log signed out prior to departing the premises.  Vendor shall then coordinate with the COR prior to performing their work.     \n\nPersonnel must wear the proper personal protective equipment (PPE) at all times.  Work done under this project must comply with infection control requirements. \n\nThe contractor shall receive all deliveries of materials, equipment, tools, or other goods off of station, and bring them to the job site.  The Manchester VA shall not accept deliveries for project purposes.  \n\nSpecial care will be taken to secure tools and construction equipment. \n\nMaterial Safety Data Sheets (MSDS s) must be submitted to the COR for approval for all hazardous materials before they are brought to the work site.  \n\nEnd of day cleanup of the work area(s) is mandatory, and all trash shall be bagged and properly disposed of offsite.  \n\nContractor vehicles, including those of their employees, are to be parked in the lower level of Lot D.   \n\nAll travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract.  Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc.\n\nDELIVERABLES\nContractor shall coordinate with the COR to provide a complete calendar year schedule for scheduled maintenance tasks at the commencement of the contract.\nContractor shall provide a prioritized phone support contact list at the commencement of the contract.\nSubmittal of proposed equipment and materials to be used on site for review and approval by the COR.\nSubmittal of Contractor safety plan and lock-out tag-out plan.\nSubmittal of Safety Data Sheets (SDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center.  Chemicals must be approved before they can be located on property.\n\nWithin two weeks of completing each visit, the vendor will provide a report on the following:\nThe final quarterly documentation report including but not limited to the following:  \nAll Fire and Smoke Door Assembly and Locations\nGeneral condition of each item repaired.\nDetailed written descriptions of repairs made. \nThis report shall include:\nName of the Contractor and Contract Number\nName of the Technician who performed services\nContractor service report.  \nService hours utilized.\nParts allowance utilized and itemized parts replaced.\nTotal cost of the visit\nIdentification of door assembly to be serviced.  (ID Number, Manufacturer's name, Fire door assembly, and any other Manufacturer's identification numbers.)\n\n6. 0 QUALIFICATIONS\nEach respondent must have an established business, with an office and full time staff.  The staff includes a \"fully qualified\" technician and a \"fully qualified\" technician who will serve as the backup.\n\"Fully Qualified\" is based upon training and on experience in the field.  For training, the technician(s) shall have successfully completed a formalized training program for the inspection, testing and maintenance of fire door assemblies, IAW the most recent edition of NFPA 80. \n\nThe technicians shall be authorized by the Contractor to perform the maintenance services.  All work shall be performed by \"Fully Qualified\" competent technicians.  The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved technician.  The CO may authenticate the training requirements, request training certificates or credentials from the Contractor at any time for any personnel who are servicing or installing any VAMC equipment.  The CO and/or COR specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on the VAMC equipment.\n\nThe Base contract period of performance is September 21, 2026 to September 20, 2027.\n\nOption Year 1: September 21, 2027 to September 20, 2028.\n\nOption Year 2: September 21, 2028 to September 20, 2029.\n\nOption Year 3: September 21, 2029 to September 20, 2030.\n\nOption Year 4: September 21, 2030 to September 20, 2031.\n\n\nPlaces of Performance\nAddress:\n718 Smyth Road\nManchester, NH\nPostal Code:\n03104\nCountry:\nUNITED STATES\n\n\n\nThe full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far. \n\nThe following solicitation provisions apply to this acquisition:\nFAR 52.212-1,  Instructions to Offerors Commercial Products and Commercial Services  (Sep 2023) (See Attachment 1).\nFAR 52.212-2 Evaluation-Commercial Products and Commercial Services: In accordance with RFO FAR 12.201-1 and FAR 12.201-2 when appropriate, the contracting officer may (1)Â Insert the provision atÂ 52.212-2, Evaluation-Commercial ProductsÂ andÂ Commercial Services, inÂ solicitationsÂ forÂ commercial productsÂ orÂ commercial services (See Attachment 2).\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/\n\n\n\nThe following contract clauses apply to this acquisition: \nFAR 52.212-4,  Contract Terms and Conditions Commercial Products and Commercial Services  (Nov 2023)\n\nFAR 52.222-90,  Addressing DEI Discrimination by Federal Contractors  (APR 2026)\nFAR 52.219-6,  Notice of Total Small Business Set-Aside  (Nov 2020)\nFAR 52.219-14,  Limitations on Subcontracting  (Oct 2022)\nFAR 52.217-8,  Option to Extend Services  (NOV 1999)\nFAR 52.217-9,  Option to Extend Term of the Contract  (MAR 2000)\nFAR 52.252-2,  Clauses Incorporated By Reference Â (Feb 1998)\nFAR 52.203 11, FAR 52.203 18, FAR 52.204 7, FAR 52.204 13, FAR 52.209 6, FAR 52.222 35, FAR 52.222 36, FAR 52.222 37, FAR 52.222 41, FAR 52.222 42, FAR 52.222 43, FAR 52.222 50, FAR 52.222 62, FAR 52.223 20, FAR 52.223 21, FAR 52.223 23, FAR 52.224 3, FAR 52.232 33, FAR 52.232 40, FAR 52.233 3, FAR 52.233 4, FAR 52.244 6, FAR 52.252 1\n\nVAAR 852.219-75,  limitations on Subcontracting  (NOV 2022).\nVAAR 852.232-72  Electronic Submission of Payment Requests  (NOV 2018)\nVAAR 852.204 70  Personal Identity Verification of Contractor Personnel  (MAY 2020)\nVAAR 852.204 72  Personnel Vetting and Credentialing  (FEB 2026)\nVAAR 852.201 70  Contracting Officer's Representative  (DEC 2022)\nVAAR 852.203 70  Commercial Advertising  (MAY 2018)\nVAAR 852.219-73  VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses  (JAN 2023) (DEVIATION)\n\n\n\n\n\n\nWage Determinations:\n\nThe following wage determination applies to this solicitation and is provided as Attachments (4 & 5):\n\nWage Determination 2015-4127 (Revision No.: 34)\nWage Determination 2015-4119 (Revision No.: 33)\n\n\n\nAll quoters shall submit the following: \n\nQuestions: Any questions must be submitted in writing no later than Wednesday 27 May 2026 at 5:00 PM EST. Answers to the questions will be posted by the following week. \n\nSite Visit information: Site visits will be held on Tuesday, 19 May 2026 at 11:00 AM EST located at the Manchester VAMC. Please contact Andrew Obrien directly (andrew.obrien@va.gov; (603) 624-4366) to schedule attendance at Manchester VAMC. Please note all questions must be submitted to Shawn Lawrence (Shawn.Lawrence@va.gov), prior to Wednesday 27 May 2026 at 5:00 PM EST. No questions will be answered at the site visit. \n\n\nQuote: Offeror shall provide a quote using the Line item table above. Offerors must also provide all applicable labor rates for the solicited services so they can be compared to the applicable wage determination for compliance with the Service Contract Labor Standards.\n\n\nAll quotes shall be sent to the Contract Specialist, Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12.\n\nComparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.   \n\n\nSubmission of your response shall be received not later than 4 June 2026 at 5:00:00 PM EST. All quotes shall be emailed to Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).  \n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. \nPoint of Contact: Shawn Lawrence, Shawn.Lawrence@va.gov.\n\nSee attached document: Attachment 1 Tailored FAR 52.212-1 Instructions to Offerors Commercial Products and Commercial Services.\nSee attached document: Attachment 2 Tailored 52.212-2 Evaluation - Commercial Products and Commercial Services.\nSee attached document: Attachment 3 852.219-75 Limitation on Subcontracting.\nSee attached document: Attachment 4 WD 2015-4119 Rev. 33.\nSee attached document: Attachment 5 WD 2015-4127 Rev. 34.\nSee attached document: Attachment 6 QASP.","text":"Combined Synopsis Solicitation\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2026-01; March 13, 2026. The most recent Federal Acquisition Circular can be found at Acquisition.gov.\n\nThis solicitation is set-aside for SDVOSB\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 541350, with a small business size standard of $11.5 Million.\nThe FSC/PSC is J042.\n\nThe Manchester VA Medical Center 718 Smyth Road, Manchester, NH 03104 is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our main campus.\n\nAll interested companies shall provide quotations for the following:\n\nSupplies/Services\n\nLine Item\nDescription\nQuantity\nUnit of Measure\nUnit Price\nTotal Price\n0001\nQuarterly Fire Door Inspections and Reports\n4\nQUARTERLY\n\n0002\nAnnual Fire Door Report\n`1\nYR\n\n0003\nStand-By Service Call hours\n160\nHR\n\n0004\nMaterials and Parts\n1000\nDoors\n\n1001\nQuarterly Fire Door Inspections and Reports Option Year 1\n4\nQUARTERLY\n\n1002\nAnnual Fire Door Report\n1\nYR\n\n1003\nStand-By Service Call hours\n160\nHR\n\n1004\nMaterials and Parts\n1000\nDoors\n\n2001\nQuarterly Fire Door Inspections and Reports Option Year 2\n4\nQUARTERLY\n\n2002\nAnnual Fire Door Report\n1\nYR\n\n2003\nStand-By Service Call hours\n160\nHR\n\n2004\nMaterials and Parts\n1000\nDoors\n\n3001\nQuarterly Fire Door Inspections and Reports Option Year 3\n4\nQUARTERLY\n\n3002\nAnnual Fire Door Report\n1\nYR\n\n3003\nStand-By Service Call hours\n160\nHR\n\n3004\nMaterials and Parts\n1000\nDoors\n\n4001\nQuarterly Fire Door Inspections and Reports Option Year 4\n4\nQUARTERLY\n\n4002\nAnnual Fire Door Report\n1\nYR\n\n4003\nStand-By Service Call hours\n160\nHR\n\n4004\nMaterials and Parts\n1000\nDoors\n\nDEPARTMENT OF VETERANS AFFAIRS\nSTATEMENT OF WORK\nService Contract Campus Wide Doors and Fire Door Inspections and Repairs\n\nINTRODUCTION\nThe VA Medical Center in Manchester is seeking a qualified contractor to perform comprehensive inspections and maintenance on all doors to include fire doors at our campus. Service performance will be for the VAMC- Manchester at 718 Smyth Road, Manchester, NH 03104.\n\nBACKGROUND\nVA Manchester s fire doors as well as non-fire doors have required inspections and maintenance on a periodic basis through the year. The Facility Service, Maintenance Department, requires assistance in keeping up with required inspections and maintenance on the campus doors to ensure proper operations and prevent failure of the fire protection system. Our current maintenance staff is shorthanded to ensure proper maintenance is being completed as well as responding to maintenance calls, performing regular duties, and handling the increase work order requests. A service contract is needed to ensure the proper and timely execution of the required inspections and maintenance of the campus wide doors. Contractor shall provide quarterly and annual inspections & reports as well as periodic maintenance to correct these deficiencies. The Campus contains approximately 1,000 doors which includes approximately 135 fire/smoke doors.\n\nThis is for a base plus 4 option year contract.\nSCOPE\nItem 1 Quarterly Fire Door Inspections\nThe contractor shall provide all personnel, equipment, tools vehicles, materials, supervision, and other items and services necessary to perform preventative maintenance, testing and repair tasks functions for the equipment described in the SOW.\n\nContractor shall provide necessary parts and labor to perform regularly scheduled preventative maintenance (PM) services for approximately 135 Fire/Smoke door assemblies, based solely on current VAMC Manchester s life safety drawings, which are available to contract awardee, upon request. The drawings are to be used as a guide to aide in locating fire/smoke doors. Location of the doors that may not be identifiable on the drawings will be provided to contractor by VAMC Manchester. No change order will be considered for credit or additional cost, unless there is more than a 10% variation from the above stated number of fire door assemblies.\n\nInspections and maintenance performed on fire door assemblies shall be in accordance with NFPA 80: Standard for Fire Doors and Other Opening Protectives, 2025 Edition - Chapter 5 Inspection, Testing, and Maintenance . The Contractor shall also review, correct and prepare a full and accurate inventory list (excel format) of all known fire door assemblies as part of this solicitation.\n\nInspections on all 135 fire/smoke doors will be performed on a quarterly basis and include all components of fire door assemblies. All visits shall be scheduled and coordinated through the COR or designee during normal business hours. Fire Door assembly Inspections / preventative maintenance shall include, but not be limited to the following:\n\nEnsure that all door assembly rating labels are intact and legible.\nEnsure glazing, vision light frames, and glazing beads are intact.\nEnsure door clearances around frames and at thresholds are appropriate.\nEnsure self-closure devices operate.\nConfirm that coordinators are installed with an inactive leaf closing before active leaf.\nEnsure latching hardware operates and secures the door when closed. Adjust as needed.\nEnsure auxiliary hardware does not interfere with operation of the door assembly.\nEnsure modifications to door assemblies do not void the labels.\nCheck gasket and edge seals and verify for presence and integrity.\n\nQuarterly Report\n\nQuarterly Report shall include the list of the fire/smoke doors, inspections performed and pass /fail on the inspections. These reports shall be delivered 14 calendar days after the date of the inspection.\n\nA cost estimate of the repairs required shall be provided for each failed item. These will be approved based on funding remaining in ITEM 3 & ITEM 4 (Labor hours and Parts).\n\nAfter Quarter 1, all other quarterly reports shall also include a list of corrections made since previous quarters report.\n\nCORRECTIONS/REPAIRS REQUIRED: The Contractor shall immediately, but no later than 14 calendar days after discovery, notify the CO and COR (in writing) of the existence or the development of any defects in, or repairs required, to the fire door assemblies. The Contractor shall furnish the CO and COR with a written estimate of the cost to make necessary repairs. (Repair costs shall be covered under Line item 3.3 Item 3 and 3.4 Item 4)\n\nThese items for repair may include some of the following:\n\nRepair or replacement of any device that does not operate as it should.\nProperly aligning doors, frames, hinges, hardware, and thresholds.\nReplacing any missing or broken parts.\nFilling and/ or repairing holes or breaks in door surfaces and frames.\n\nItem 2 Annual Report\nThe contractor shall provide the VA with an annual report on all fire door quarterly inspections and a wrap up of corrective actions.\nThis report shall include:\nFire door locations / labels and quarterly inspections (pass / fail).\nFire doors repairs by location\nType of failures (from highest quantity failure reason to lowest)\nOutstanding items to be repaired / replaced.\n\nItem 3- Stand-by Services (Labor)\nThe contractor shall provide on repair services to include labor costs for standby repair services related to repairs associated with doors across campus. These labor hours include labor hours associated with repairs to the fire/smoke door assemblies as well as hours associated with services requested for repair of non- fire/smoke doors.\nThese labor hours are not associated with the inspections and reporting labor hours.\nThe vendor will be able to schedule staffing within two (2) weeks of notification.\nContractor shall provide 160 labor hours as specified under this line item.\n\nItem 4 Materials and Parts (Non-Routine Repairs and Maintenance)\nThe contractor shall supply parts and materials ($150 per door) for approximately 1,000 doors (inclusive of fire/smoke doors) as needed for necessary upgrades, replacement, and repairs. If cost exceeds the agreed upon limitation ($150 per door), then a list of repairs required as a result of the inspection will be provided with a cost proposal for the repair within 14 calendar days to the COR.\nRepairs shall be commenced within 14 calendar days after the costs for repair has been agreed upon by the contractor or by the COR. All repairs shall be in accordance with the manufacturer s requirements and\\or applicable laws, regulations, codes, etc. All parts and materials shall be of the original manufacturer s design and specification, or equal thereto. An extension may be granted at the discretion of the COR on a case by case basis. Each request for an extension must include and explanation for the delay, and estimated time of completion, and evidence to clearly show that the contractor has made every effort to repair the system as timely as possible.\n\nPERFORMANCE REQUIREMENTS\nAll work shall be completed such that the integrity of the systems is maintained. All work shall be done in accordance with OSHA, EPA regulations, NFPA codes, with particular attention to VA codes, Federal, State, and local regulations throughout the course of this service contract.\nThe Contractor shall submit technician certification/licensure prior to work start. Copies of these are also to be submitted with the completed checklists.\n\nThe contractor shall submit all necessary safety plans to include, but not limited to; equipment specific Lock-Out Tag Out procedures, Electrical Safety plan and SDS for any chemicals used to the COR for approval prior to working at the Medical Center.\n\nThe contractor shall schedule all site visits, to include emergencies, with the COR.\n\nThe contractor shall furnish authentic parts from the equipment manufacturer. The determination of when to replace parts is at the recommendation of the technician, with the COR s concurrence. Additional service charges may be incurred to install parts during scheduled inspections or callbacks as specified in this agreement.\n\nThe contractor shall operate on the premises during the hours of 0700 and 1630, unless otherwise authorized by the COR.\n\nThe contractor shall respond within 4 hours for all emergency call backs.\n\nWork sites shall be left in the same manner of cleanliness and order in which they were found. Vendor will provide their own waste disposal, if any.\n\nAll vendor technicians performing work on site must report to Facility Service in Building 6 to the contractor badge check in/out room to sign in on the contractor log and get a Contractor badge. Badges must be returned, and log signed out prior to departing the premises. Vendor shall then coordinate with the COR prior to performing their work.\n\nPersonnel must wear the proper personal protective equipment (PPE) at all times. Work done under this project must comply with infection control requirements.\n\nThe contractor shall receive all deliveries of materials, equipment, tools, or other goods off of station, and bring them to the job site. The Manchester VA shall not accept deliveries for project purposes.\n\nSpecial care will be taken to secure tools and construction equipment.\n\nMaterial Safety Data Sheets (MSDS s) must be submitted to the COR for approval for all hazardous materials before they are brought to the work site.\n\nEnd of day cleanup of the work area(s) is mandatory, and all trash shall be bagged and properly disposed of offsite.\n\nContractor vehicles, including those of their employees, are to be parked in the lower level of Lot D.\n\nAll travel costs associated with performance of this contract are the responsibility of the Contractor and are provided at no additional cost to the government as part of this contract. Travel costs are defined but not limited to time and vehicle costs for personnel in travel to and from job site for all duties outlined in this specification, normal shipping charges on any parts or materials covered by this contract, costs associated with the normal shipping of parts or equipment out for repair that are covered under this contract, etc.\n\nDELIVERABLES\nContractor shall coordinate with the COR to provide a complete calendar year schedule for scheduled maintenance tasks at the commencement of the contract.\nContractor shall provide a prioritized phone support contact list at the commencement of the contract.\nSubmittal of proposed equipment and materials to be used on site for review and approval by the COR.\nSubmittal of Contractor safety plan and lock-out tag-out plan.\nSubmittal of Safety Data Sheets (SDS) shall be provided by the contactor for all chemicals proposed to be brought to the medical center. Chemicals must be approved before they can be located on property.\n\nWithin two weeks of completing each visit, the vendor will provide a report on the following:\nThe final quarterly documentation report including but not limited to the following:\nAll Fire and Smoke Door Assembly and Locations\nGeneral condition of each item repaired.\nDetailed written descriptions of repairs made.\nThis report shall include:\nName of the Contractor and Contract Number\nName of the Technician who performed services\nContractor service report.\nService hours utilized.\nParts allowance utilized and itemized parts replaced.\nTotal cost of the visit\nIdentification of door assembly to be serviced. (ID Number, Manufacturer's name, Fire door assembly, and any other Manufacturer's identification numbers.)\n\n6. 0 QUALIFICATIONS\nEach respondent must have an established business, with an office and full time staff. The staff includes a \"fully qualified\" technician and a \"fully qualified\" technician who will serve as the backup.\n\"Fully Qualified\" is based upon training and on experience in the field. For training, the technician(s) shall have successfully completed a formalized training program for the inspection, testing and maintenance of fire door assemblies, IAW the most recent edition of NFPA 80.\n\nThe technicians shall be authorized by the Contractor to perform the maintenance services. All work shall be performed by \"Fully Qualified\" competent technicians. The Contractor shall provide written assurance of the competency of their personnel and a list of credentials of approved technician. The CO may authenticate the training requirements, request training certificates or credentials from the Contractor at any time for any personnel who are servicing or installing any VAMC equipment. The CO and/or COR specifically reserve the right to reject any of the Contractor's personnel and refuse them permission to work on the VAMC equipment.\n\nThe Base contract period of performance is September 21, 2026 to September 20, 2027.\n\nOption Year 1: September 21, 2027 to September 20, 2028.\n\nOption Year 2: September 21, 2028 to September 20, 2029.\n\nOption Year 3: September 21, 2029 to September 20, 2030.\n\nOption Year 4: September 21, 2030 to September 20, 2031.\n\nPlaces of Performance\nAddress:\n718 Smyth Road\nManchester, NH\nPostal Code:\n03104\nCountry:\nUNITED STATES\n\nThe full text of FAR provisions or clauses may be accessed electronically at https://www.acquisition.gov/browse/index/far.\n\nThe following solicitation provisions apply to this acquisition:\nFAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services (Sep 2023) (See Attachment 1).\nFAR 52.212-2 Evaluation-Commercial Products and Commercial Services: In accordance with RFO FAR 12.201-1 and FAR 12.201-2 when appropriate, the contracting officer may (1)Â Insert the provision atÂ 52.212-2, Evaluation-Commercial ProductsÂ andÂ Commercial Services, inÂ solicitationsÂ forÂ commercial productsÂ orÂ commercial services (See Attachment 2).\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/\n\nThe following contract clauses apply to this acquisition:\nFAR 52.212-4, Contract Terms and Conditions Commercial Products and Commercial Services (Nov 2023)\n\nFAR 52.222-90, Addressing DEI Discrimination by Federal Contractors (APR 2026)\nFAR 52.219-6, Notice of Total Small Business Set-Aside (Nov 2020)\nFAR 52.219-14, Limitations on Subcontracting (Oct 2022)\nFAR 52.217-8, Option to Extend Services (NOV 1999)\nFAR 52.217-9, Option to Extend Term of the Contract (MAR 2000)\nFAR 52.252-2, Clauses Incorporated By Reference Â (Feb 1998)\nFAR 52.203 11, FAR 52.203 18, FAR 52.204 7, FAR 52.204 13, FAR 52.209 6, FAR 52.222 35, FAR 52.222 36, FAR 52.222 37, FAR 52.222 41, FAR 52.222 42, FAR 52.222 43, FAR 52.222 50, FAR 52.222 62, FAR 52.223 20, FAR 52.223 21, FAR 52.223 23, FAR 52.224 3, FAR 52.232 33, FAR 52.232 40, FAR 52.233 3, FAR 52.233 4, FAR 52.244 6, FAR 52.252 1\n\nVAAR 852.219-75, limitations on Subcontracting (NOV 2022).\nVAAR 852.232-72 Electronic Submission of Payment Requests (NOV 2018)\nVAAR 852.204 70 Personal Identity Verification of Contractor Personnel (MAY 2020)\nVAAR 852.204 72 Personnel Vetting and Credentialing (FEB 2026)\nVAAR 852.201 70 Contracting Officer's Representative (DEC 2022)\nVAAR 852.203 70 Commercial Advertising (MAY 2018)\nVAAR 852.219-73 VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses (JAN 2023) (DEVIATION)\n\nWage Determinations:\n\nThe following wage determination applies to this solicitation and is provided as Attachments (4 & 5):\n\nWage Determination 2015-4127 (Revision No.: 34)\nWage Determination 2015-4119 (Revision No.: 33)\n\nAll quoters shall submit the following:\n\nQuestions: Any questions must be submitted in writing no later than Wednesday 27 May 2026 at 5:00 PM EST. Answers to the questions will be posted by the following week.\n\nSite Visit information: Site visits will be held on Tuesday, 19 May 2026 at 11:00 AM EST located at the Manchester VAMC. Please contact Andrew Obrien directly (andrew.obrien@va.gov; (603) 624-4366) to schedule attendance at Manchester VAMC. Please note all questions must be submitted to Shawn Lawrence (Shawn.Lawrence@va.gov), prior to Wednesday 27 May 2026 at 5:00 PM EST. No questions will be answered at the site visit.\n\nQuote: Offeror shall provide a quote using the Line item table above. Offerors must also provide all applicable labor rates for the solicited services so they can be compared to the applicable wage determination for compliance with the Service Contract Labor Standards.\n\nAll quotes shall be sent to the Contract Specialist, Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of RFO FAR 12.\n\nComparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.\n\nSubmission of your response shall be received not later than 4 June 2026 at 5:00:00 PM EST. All quotes shall be emailed to Shawn Lawrence at Shawn.Lawrence@va.gov.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\n\nAny questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below.\nPoint of Contact: Shawn Lawrence, Shawn.Lawrence@va.gov.\n\nSee attached document: Attachment 1 Tailored FAR 52.212-1 Instructions to Offerors Commercial Products and Commercial Services.\nSee attached document: Attachment 2 Tailored 52.212-2 Evaluation - Commercial Products and Commercial Services.\nSee attached document: Attachment 3 852.219-75 Limitation on Subcontracting.\nSee attached document: Attachment 4 WD 2015-4119 Rev. 33.\nSee attached document: Attachment 5 WD 2015-4127 Rev. 34.\nSee attached document: Attachment 6 QASP.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24126Q0497","place_of_performance":{"zip":"03104","city":{"code":"45140","name":"Manchester"},"state":{"code":"NH","name":"New Hampshire"},"street":"Manchester VA Medical Center","country":{"code":"USA","name":"UNITED STATES"},"street2":"718 Smyth Road"},"product_service_code":"J042"},{"dates":{"posted":"2026-06-24","posted_at":"2026-06-24T20:10:37.617Z","created_at":"2026-06-24T20:10:29.094Z","modified_at":"2026-09-09T15:27:33.178Z","response_deadline":{"raw":"2026-07-02T15:00:00-04:00","utc":"2026-07-02T19:00:00Z","date":"2026-07-02","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/09d88714ec5a4550a4980f4f2177439b/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"J042--Door Inspections and Repair Service Contract","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2026-08-01","archive_type":"auto_custom"},"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}],"contacts":[{"name":"Shawn Lawrence","role":"primary","email":"Shawn.Lawrence@va.gov","phone":"203-932-5711","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"09d88714ec5a4550a4980f4f2177439b","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"03798b450615493fb5e0d5943e679d8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T04:30:44.491345668Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"99b525a9d05c2b9f7f37756c7edae108-29\"","fetched_at":"2026-09-21T04:08:22.069689491Z","row_sha256":"1113ed5665b24a0111cf86f8d9e056a88ac9af23e1911f8d3a2abc220ddde245","last_modified":"2026-09-21T03:30:31Z"},"updated_at":"2026-09-21T04:08:22.069689491Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"RFI Sol# 36C24126Q0497 - Fire/Doors Inspection and Repairs\n\nWho currently conducts monthly, quarterly or annual routine inspection, preventative maintenance on the 865 non-fire doors? Â i.e. External contractor or VA staff?Â \n\nANSWER: The non-fire doors are inspected in house. As part of the contract these doors will continue to be inspected in house. We may request the contractor make repairs to these doors as needed utilizing funds from CLINs 3.3(Labor) and 3.4(materials)\n\nFire Doors are the only doors that are required to be inspected by the contractor and for the contractor to provide a report for. Repairs to these doors shall also utilize CLINs 3.3(Labor) and 3.4(materials)\n\nThe scope of the SOW seems to exclude routine inspection or maintenance on the non-fire doors, and covers only procurement of material and parts for those 865 doors.Â  Please can you confirm this.Â \n\nANSWER: That is correct. See response to RFI 1\n\nIn relation to the labor cost for installation of the material and parts for the non-fire doors - which CLIN line does this pull from or can this labor cost be billed separately?\nANSWER: Non-Fire doors and Fire door labor hours for repairs are under CLIN 3.3 STAND BY SERVICES   160 hours. All hours for INSPECTIONS AND REPORTS are billed under CLINS 3.1 and 3.2\nIs the annual parts and material line item of $150,000 per year for 1000 doors to be inserted in the CLIN by the contractor or left blank for the VA to include?Â Â \n\nANSWER: Parts and Materials are part of CLIN 3.4 MATERIALS and PARTS    All Material and parts as listed in CLIN 3.4 are part of the contract and are bid at time of contract. 1,000 doors at $150 per door to cover incidental repairs for all 1000 doors (Fire and Non-Fire doors) LABOR is part of CLIN 3.3\n\nWho is the current/incumbent awardee and what is the existing contract number.\nANSWER: Current awardee is Diversified Site Services. Contract is up for rebid as contract period of performance has expired. Other contractors in the past have been Door Innovations and DH Pace. \nFire/smoke doors are typically inspected annually, specifically for the VA and Joint Commission. Can you please explain why this solicitation requires inspections on a quarterly basis? This is 4 times the amount of work that is required by code, or are you asking for Â¼ of the fire/smoke doors (~34 doors) inspected each quarter?\n\nANSWER: We experienced repairs that were getting documented as corrections to fire doors only to fail on the next annual inspection. While we agree that it is only required once per year, the previous failures of repairs and compliance has lead us to require it quarterly. \nIs the $150 per door a pre-determined Government NTE that should be entered into the price schedule, or is it a hard cap for individual repairs? To ensure all offers are evaluated the same for this line item, can you clarify how offerors should price CLIN 0004 (leave it blank, use $150,000, NSP, etc.)?\nANSWER: See response to RFI #4. Bid as 1000 doors at $150 per door. \nHow will emergency calls outside of the stated normal business hours (0700 to 1630) be billed? Should offerors include an after-hours/overtime labor rate in addition to the standard stand-by rate? \nANSWER: Emergency calls and 4-hour response time is EXCLUDED from this contract. It was an inadvertent carry-over from another service contract. All calls/communication SHALL NOT be required to be addressed within a four-hour response time. The expectation is that a response shall be provided within a week and work scheduled from there.\n\nDoes the VA have a current and accurate inventory document, or does the offeror have to create one from scratch?\n\nANSWER: The VA has an accurate and current inventory and status report. At the time of bidding the VA is 92% compliant with all doors and expected to be at 100% compliance before bid award.  Offeror shall be provided a list of fire doors and locations at the start of the contract to build into a report\n\nSection 1.0 Introduction states to provide inspection and maintenance services on all 1000 doors to include 135 fire doors, but the entire scope of work section appears to be only focused on fire rated doors. Can you please explain the services being requested on the non-fire rated doors? NFPA 80 does not cover inspection requirement for non-fire rated doors, and the scope of work (Section 3.0) currently doesn t define specific tasks for non-fire rated door inspections.\nAre we required only to provide repairs on non-fire/smoke rated doors?\nANSWER: Services being request on non-fire doors are covered by line items 3.3 and 3.4 and answered under RFI #1. Contractor to inspect fire doors and provide report this is covered under 3.1 and 3.2. \n\nNon-Fire doors are inspected internally by VA Staff. Repairs to fire doors and non Fire doors are covered under 3.3 and 3.4. See RFI #1 for additional clarification. \n\nDo you have a checklist for non-fire rated door inspections?\nANSWER: No inspection of NON-FIRE rated doors is required by the contractor.\nAre these door quantities of approximately 1000 total and 135 for fire/smoke doors all single leaf swinging doors, or are there double leaf doors (please specify how many double leaf doors)?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nAre there any other types of fire rated doors such as horizontal sliders, drop or roll down doors, etc.? If so, can you please provide a more detailed quantity of doors identifying how many of each type so we can ensure we provide an accurate price.\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nThe scope of work mentions preventative maintenance services. Can you please confirm the preventative maintenance services are the  Standby Service Call Hours  reserved in the supplies and services table for any maintenance work needed?\nOr do you have other preventative maintenance services that we need to perform on a periodic basis which should be included in line items 0001 and 0002?\nANSWER: All preventative maintenance such as; shimming, replacing astragals, replacing /repairing exit hardware, etc. shall be covered under line items 3.3 and 3.4\n\nCan you please provide a copy of the most recent life safety drawing referenced in the solicitation so we can review door locations?\nANSWER: YES, Attached\nCan you please provide copies of the most recent door inspection reports for both fire-rated and non-fire rated doors?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification. Non-fire doors are not inspected by the contractor.\n\n In regards to the Manchester VA door inspection and repair service request for quote - how many doors do we carry for the $150 repair charge ?Â  All 1000 doors ?Â  So a total of $150,000.00 for line itemÂ 4.Â  And if I read it correctly, if the cost of material/parts exceeds $150 per door, to issue a detailed change order ?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door.\nThe solicitation references approximately 135 fire doors for inspection, but the pricing schedule lists CLIN 0004 with a quantity of 1,000 doors. Additionally, the Performance Work Statement indicates that contractors should carry $150 in materials per door.\nCould you please clarify the intended basis for pricing CLIN 0004?\n\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.\nSpecifically, should offerors carry:\n$150 Ã— 1,000 doors ($150,000), based on the quantity shown in the pricing schedule, or \n$150 Ã— approximately 135 doors (approximately $20,250), based on the stated number of fire doors in the facility inventory? \nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.","text":"RFI Sol# 36C24126Q0497 - Fire/Doors Inspection and Repairs\n\nWho currently conducts monthly, quarterly or annual routine inspection, preventative maintenance on the 865 non-fire doors? Â i.e. External contractor or VA staff?Â\n\nANSWER: The non-fire doors are inspected in house. As part of the contract these doors will continue to be inspected in house. We may request the contractor make repairs to these doors as needed utilizing funds from CLINs 3.3(Labor) and 3.4(materials)\n\nFire Doors are the only doors that are required to be inspected by the contractor and for the contractor to provide a report for. Repairs to these doors shall also utilize CLINs 3.3(Labor) and 3.4(materials)\n\nThe scope of the SOW seems to exclude routine inspection or maintenance on the non-fire doors, and covers only procurement of material and parts for those 865 doors.Â Please can you confirm this.Â\n\nANSWER: That is correct. See response to RFI 1\n\nIn relation to the labor cost for installation of the material and parts for the non-fire doors - which CLIN line does this pull from or can this labor cost be billed separately?\nANSWER: Non-Fire doors and Fire door labor hours for repairs are under CLIN 3.3 STAND BY SERVICES 160 hours. All hours for INSPECTIONS AND REPORTS are billed under CLINS 3.1 and 3.2\nIs the annual parts and material line item of $150,000 per year for 1000 doors to be inserted in the CLIN by the contractor or left blank for the VA to include?Â Â\n\nANSWER: Parts and Materials are part of CLIN 3.4 MATERIALS and PARTS All Material and parts as listed in CLIN 3.4 are part of the contract and are bid at time of contract. 1,000 doors at $150 per door to cover incidental repairs for all 1000 doors (Fire and Non-Fire doors) LABOR is part of CLIN 3.3\n\nWho is the current/incumbent awardee and what is the existing contract number.\nANSWER: Current awardee is Diversified Site Services. Contract is up for rebid as contract period of performance has expired. Other contractors in the past have been Door Innovations and DH Pace.\nFire/smoke doors are typically inspected annually, specifically for the VA and Joint Commission. Can you please explain why this solicitation requires inspections on a quarterly basis? This is 4 times the amount of work that is required by code, or are you asking for Â¼ of the fire/smoke doors (~34 doors) inspected each quarter?\n\nANSWER: We experienced repairs that were getting documented as corrections to fire doors only to fail on the next annual inspection. While we agree that it is only required once per year, the previous failures of repairs and compliance has lead us to require it quarterly.\nIs the $150 per door a pre-determined Government NTE that should be entered into the price schedule, or is it a hard cap for individual repairs? To ensure all offers are evaluated the same for this line item, can you clarify how offerors should price CLIN 0004 (leave it blank, use $150,000, NSP, etc.)?\nANSWER: See response to RFI #4. Bid as 1000 doors at $150 per door.\nHow will emergency calls outside of the stated normal business hours (0700 to 1630) be billed? Should offerors include an after-hours/overtime labor rate in addition to the standard stand-by rate?\nANSWER: Emergency calls and 4-hour response time is EXCLUDED from this contract. It was an inadvertent carry-over from another service contract. All calls/communication SHALL NOT be required to be addressed within a four-hour response time. The expectation is that a response shall be provided within a week and work scheduled from there.\n\nDoes the VA have a current and accurate inventory document, or does the offeror have to create one from scratch?\n\nANSWER: The VA has an accurate and current inventory and status report. At the time of bidding the VA is 92% compliant with all doors and expected to be at 100% compliance before bid award. Offeror shall be provided a list of fire doors and locations at the start of the contract to build into a report\n\nSection 1.0 Introduction states to provide inspection and maintenance services on all 1000 doors to include 135 fire doors, but the entire scope of work section appears to be only focused on fire rated doors. Can you please explain the services being requested on the non-fire rated doors? NFPA 80 does not cover inspection requirement for non-fire rated doors, and the scope of work (Section 3.0) currently doesn t define specific tasks for non-fire rated door inspections.\nAre we required only to provide repairs on non-fire/smoke rated doors?\nANSWER: Services being request on non-fire doors are covered by line items 3.3 and 3.4 and answered under RFI #1. Contractor to inspect fire doors and provide report this is covered under 3.1 and 3.2.\n\nNon-Fire doors are inspected internally by VA Staff. Repairs to fire doors and non Fire doors are covered under 3.3 and 3.4. See RFI #1 for additional clarification.\n\nDo you have a checklist for non-fire rated door inspections?\nANSWER: No inspection of NON-FIRE rated doors is required by the contractor.\nAre these door quantities of approximately 1000 total and 135 for fire/smoke doors all single leaf swinging doors, or are there double leaf doors (please specify how many double leaf doors)?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nAre there any other types of fire rated doors such as horizontal sliders, drop or roll down doors, etc.? If so, can you please provide a more detailed quantity of doors identifying how many of each type so we can ensure we provide an accurate price.\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nThe scope of work mentions preventative maintenance services. Can you please confirm the preventative maintenance services are the Standby Service Call Hours reserved in the supplies and services table for any maintenance work needed?\nOr do you have other preventative maintenance services that we need to perform on a periodic basis which should be included in line items 0001 and 0002?\nANSWER: All preventative maintenance such as; shimming, replacing astragals, replacing /repairing exit hardware, etc. shall be covered under line items 3.3 and 3.4\n\nCan you please provide a copy of the most recent life safety drawing referenced in the solicitation so we can review door locations?\nANSWER: YES, Attached\nCan you please provide copies of the most recent door inspection reports for both fire-rated and non-fire rated doors?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification. Non-fire doors are not inspected by the contractor.\n\nIn regards to the Manchester VA door inspection and repair service request for quote - how many doors do we carry for the $150 repair charge ?Â All 1000 doors ?Â So a total of $150,000.00 for line itemÂ 4.Â And if I read it correctly, if the cost of material/parts exceeds $150 per door, to issue a detailed change order ?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door.\nThe solicitation references approximately 135 fire doors for inspection, but the pricing schedule lists CLIN 0004 with a quantity of 1,000 doors. Additionally, the Performance Work Statement indicates that contractors should carry $150 in materials per door.\nCould you please clarify the intended basis for pricing CLIN 0004?\n\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.\nSpecifically, should offerors carry:\n$150 Ã— 1,000 doors ($150,000), based on the quantity shown in the pricing schedule, or\n$150 Ã— approximately 135 doors (approximately $20,250), based on the stated number of fire doors in the facility inventory?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24126Q0497","place_of_performance":{"zip":"03104","city":{"name":"Manchester"},"state":{"code":"NH"},"street":"Manchester VA Medical Center 718 Smyth Road","country":{"code":"USA"}},"product_service_code":"J042"},{"dates":{"posted":"2026-06-24","posted_at":"2026-06-24T20:10:46.185Z","created_at":"2026-06-24T20:10:36.715Z","modified_at":"2026-09-09T15:27:33.178Z","response_deadline":{"raw":"2026-07-02T15:00:00-04:00","utc":"2026-07-02T19:00:00Z","date":"2026-07-02","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3bda2571f43c494eb3fbc14dc08da82a/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"J042--Door Inspections and Repair Service Contract","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":false,"publication":"published","archive_date":"2026-08-01","archive_type":"auto_custom"},"history":[{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}],"contacts":[{"name":"Shawn Lawrence","role":"primary","email":"Shawn.Lawrence@va.gov","phone":"203-932-5711","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"3bda2571f43c494eb3fbc14dc08da82a","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"03798b450615493fb5e0d5943e679d8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-20T04:34:47.489859078Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"99b525a9d05c2b9f7f37756c7edae108-29\"","fetched_at":"2026-09-21T04:08:22.069689491Z","row_sha256":"347bc9799c6c0f9f2dd9ff4c83e922244c58b8d9bafd102048fae3b9b8bfbd23","last_modified":"2026-09-21T03:30:31Z"},"updated_at":"2026-09-21T04:08:22.069689491Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"RFI Sol# 36C24126Q0497 - Fire/Doors Inspection and Repairs\n\nWho currently conducts monthly, quarterly or annual routine inspection, preventative maintenance on the 865 non-fire doors? Â i.e. External contractor or VA staff?Â \n\nANSWER: The non-fire doors are inspected in house. As part of the contract these doors will continue to be inspected in house. We may request the contractor make repairs to these doors as needed utilizing funds from CLINs 3.3(Labor) and 3.4(materials)\n\nFire Doors are the only doors that are required to be inspected by the contractor and for the contractor to provide a report for. Repairs to these doors shall also utilize CLINs 3.3(Labor) and 3.4(materials)\n\nThe scope of the SOW seems to exclude routine inspection or maintenance on the non-fire doors, and covers only procurement of material and parts for those 865 doors.Â  Please can you confirm this.Â \n\nANSWER: That is correct. See response to RFI 1\n\nIn relation to the labor cost for installation of the material and parts for the non-fire doors - which CLIN line does this pull from or can this labor cost be billed separately?\nANSWER: Non-Fire doors and Fire door labor hours for repairs are under CLIN 3.3 STAND BY SERVICES   160 hours. All hours for INSPECTIONS AND REPORTS are billed under CLINS 3.1 and 3.2\nIs the annual parts and material line item of $150,000 per year for 1000 doors to be inserted in the CLIN by the contractor or left blank for the VA to include?Â Â \n\nANSWER: Parts and Materials are part of CLIN 3.4 MATERIALS and PARTS    All Material and parts as listed in CLIN 3.4 are part of the contract and are bid at time of contract. 1,000 doors at $150 per door to cover incidental repairs for all 1000 doors (Fire and Non-Fire doors) LABOR is part of CLIN 3.3\n\nWho is the current/incumbent awardee and what is the existing contract number.\nANSWER: Current awardee is Diversified Site Services. Contract is up for rebid as contract period of performance has expired. Other contractors in the past have been Door Innovations and DH Pace. \nFire/smoke doors are typically inspected annually, specifically for the VA and Joint Commission. Can you please explain why this solicitation requires inspections on a quarterly basis? This is 4 times the amount of work that is required by code, or are you asking for Â¼ of the fire/smoke doors (~34 doors) inspected each quarter?\n\nANSWER: We experienced repairs that were getting documented as corrections to fire doors only to fail on the next annual inspection. While we agree that it is only required once per year, the previous failures of repairs and compliance has lead us to require it quarterly. \nIs the $150 per door a pre-determined Government NTE that should be entered into the price schedule, or is it a hard cap for individual repairs? To ensure all offers are evaluated the same for this line item, can you clarify how offerors should price CLIN 0004 (leave it blank, use $150,000, NSP, etc.)?\nANSWER: See response to RFI #4. Bid as 1000 doors at $150 per door. \nHow will emergency calls outside of the stated normal business hours (0700 to 1630) be billed? Should offerors include an after-hours/overtime labor rate in addition to the standard stand-by rate? \nANSWER: Emergency calls and 4-hour response time is EXCLUDED from this contract. It was an inadvertent carry-over from another service contract. All calls/communication SHALL NOT be required to be addressed within a four-hour response time. The expectation is that a response shall be provided within a week and work scheduled from there.\n\nDoes the VA have a current and accurate inventory document, or does the offeror have to create one from scratch?\n\nANSWER: The VA has an accurate and current inventory and status report. At the time of bidding the VA is 92% compliant with all doors and expected to be at 100% compliance before bid award.  Offeror shall be provided a list of fire doors and locations at the start of the contract to build into a report\n\nSection 1.0 Introduction states to provide inspection and maintenance services on all 1000 doors to include 135 fire doors, but the entire scope of work section appears to be only focused on fire rated doors. Can you please explain the services being requested on the non-fire rated doors? NFPA 80 does not cover inspection requirement for non-fire rated doors, and the scope of work (Section 3.0) currently doesn t define specific tasks for non-fire rated door inspections.\nAre we required only to provide repairs on non-fire/smoke rated doors?\nANSWER: Services being request on non-fire doors are covered by line items 3.3 and 3.4 and answered under RFI #1. Contractor to inspect fire doors and provide report this is covered under 3.1 and 3.2. \n\nNon-Fire doors are inspected internally by VA Staff. Repairs to fire doors and non Fire doors are covered under 3.3 and 3.4. See RFI #1 for additional clarification. \n\nDo you have a checklist for non-fire rated door inspections?\nANSWER: No inspection of NON-FIRE rated doors is required by the contractor.\nAre these door quantities of approximately 1000 total and 135 for fire/smoke doors all single leaf swinging doors, or are there double leaf doors (please specify how many double leaf doors)?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nAre there any other types of fire rated doors such as horizontal sliders, drop or roll down doors, etc.? If so, can you please provide a more detailed quantity of doors identifying how many of each type so we can ensure we provide an accurate price.\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nThe scope of work mentions preventative maintenance services. Can you please confirm the preventative maintenance services are the  Standby Service Call Hours  reserved in the supplies and services table for any maintenance work needed?\nOr do you have other preventative maintenance services that we need to perform on a periodic basis which should be included in line items 0001 and 0002?\nANSWER: All preventative maintenance such as; shimming, replacing astragals, replacing /repairing exit hardware, etc. shall be covered under line items 3.3 and 3.4\n\nCan you please provide a copy of the most recent life safety drawing referenced in the solicitation so we can review door locations?\nANSWER: YES, Attached\nCan you please provide copies of the most recent door inspection reports for both fire-rated and non-fire rated doors?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification. Non-fire doors are not inspected by the contractor.\n\n In regards to the Manchester VA door inspection and repair service request for quote - how many doors do we carry for the $150 repair charge ?Â  All 1000 doors ?Â  So a total of $150,000.00 for line itemÂ 4.Â  And if I read it correctly, if the cost of material/parts exceeds $150 per door, to issue a detailed change order ?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door.\nThe solicitation references approximately 135 fire doors for inspection, but the pricing schedule lists CLIN 0004 with a quantity of 1,000 doors. Additionally, the Performance Work Statement indicates that contractors should carry $150 in materials per door.\nCould you please clarify the intended basis for pricing CLIN 0004?\n\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.\nSpecifically, should offerors carry:\n$150 Ã— 1,000 doors ($150,000), based on the quantity shown in the pricing schedule, or \n$150 Ã— approximately 135 doors (approximately $20,250), based on the stated number of fire doors in the facility inventory? \nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.","text":"RFI Sol# 36C24126Q0497 - Fire/Doors Inspection and Repairs\n\nWho currently conducts monthly, quarterly or annual routine inspection, preventative maintenance on the 865 non-fire doors? Â i.e. External contractor or VA staff?Â\n\nANSWER: The non-fire doors are inspected in house. As part of the contract these doors will continue to be inspected in house. We may request the contractor make repairs to these doors as needed utilizing funds from CLINs 3.3(Labor) and 3.4(materials)\n\nFire Doors are the only doors that are required to be inspected by the contractor and for the contractor to provide a report for. Repairs to these doors shall also utilize CLINs 3.3(Labor) and 3.4(materials)\n\nThe scope of the SOW seems to exclude routine inspection or maintenance on the non-fire doors, and covers only procurement of material and parts for those 865 doors.Â Please can you confirm this.Â\n\nANSWER: That is correct. See response to RFI 1\n\nIn relation to the labor cost for installation of the material and parts for the non-fire doors - which CLIN line does this pull from or can this labor cost be billed separately?\nANSWER: Non-Fire doors and Fire door labor hours for repairs are under CLIN 3.3 STAND BY SERVICES 160 hours. All hours for INSPECTIONS AND REPORTS are billed under CLINS 3.1 and 3.2\nIs the annual parts and material line item of $150,000 per year for 1000 doors to be inserted in the CLIN by the contractor or left blank for the VA to include?Â Â\n\nANSWER: Parts and Materials are part of CLIN 3.4 MATERIALS and PARTS All Material and parts as listed in CLIN 3.4 are part of the contract and are bid at time of contract. 1,000 doors at $150 per door to cover incidental repairs for all 1000 doors (Fire and Non-Fire doors) LABOR is part of CLIN 3.3\n\nWho is the current/incumbent awardee and what is the existing contract number.\nANSWER: Current awardee is Diversified Site Services. Contract is up for rebid as contract period of performance has expired. Other contractors in the past have been Door Innovations and DH Pace.\nFire/smoke doors are typically inspected annually, specifically for the VA and Joint Commission. Can you please explain why this solicitation requires inspections on a quarterly basis? This is 4 times the amount of work that is required by code, or are you asking for Â¼ of the fire/smoke doors (~34 doors) inspected each quarter?\n\nANSWER: We experienced repairs that were getting documented as corrections to fire doors only to fail on the next annual inspection. While we agree that it is only required once per year, the previous failures of repairs and compliance has lead us to require it quarterly.\nIs the $150 per door a pre-determined Government NTE that should be entered into the price schedule, or is it a hard cap for individual repairs? To ensure all offers are evaluated the same for this line item, can you clarify how offerors should price CLIN 0004 (leave it blank, use $150,000, NSP, etc.)?\nANSWER: See response to RFI #4. Bid as 1000 doors at $150 per door.\nHow will emergency calls outside of the stated normal business hours (0700 to 1630) be billed? Should offerors include an after-hours/overtime labor rate in addition to the standard stand-by rate?\nANSWER: Emergency calls and 4-hour response time is EXCLUDED from this contract. It was an inadvertent carry-over from another service contract. All calls/communication SHALL NOT be required to be addressed within a four-hour response time. The expectation is that a response shall be provided within a week and work scheduled from there.\n\nDoes the VA have a current and accurate inventory document, or does the offeror have to create one from scratch?\n\nANSWER: The VA has an accurate and current inventory and status report. At the time of bidding the VA is 92% compliant with all doors and expected to be at 100% compliance before bid award. Offeror shall be provided a list of fire doors and locations at the start of the contract to build into a report\n\nSection 1.0 Introduction states to provide inspection and maintenance services on all 1000 doors to include 135 fire doors, but the entire scope of work section appears to be only focused on fire rated doors. Can you please explain the services being requested on the non-fire rated doors? NFPA 80 does not cover inspection requirement for non-fire rated doors, and the scope of work (Section 3.0) currently doesn t define specific tasks for non-fire rated door inspections.\nAre we required only to provide repairs on non-fire/smoke rated doors?\nANSWER: Services being request on non-fire doors are covered by line items 3.3 and 3.4 and answered under RFI #1. Contractor to inspect fire doors and provide report this is covered under 3.1 and 3.2.\n\nNon-Fire doors are inspected internally by VA Staff. Repairs to fire doors and non Fire doors are covered under 3.3 and 3.4. See RFI #1 for additional clarification.\n\nDo you have a checklist for non-fire rated door inspections?\nANSWER: No inspection of NON-FIRE rated doors is required by the contractor.\nAre these door quantities of approximately 1000 total and 135 for fire/smoke doors all single leaf swinging doors, or are there double leaf doors (please specify how many double leaf doors)?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nAre there any other types of fire rated doors such as horizontal sliders, drop or roll down doors, etc.? If so, can you please provide a more detailed quantity of doors identifying how many of each type so we can ensure we provide an accurate price.\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nThe scope of work mentions preventative maintenance services. Can you please confirm the preventative maintenance services are the Standby Service Call Hours reserved in the supplies and services table for any maintenance work needed?\nOr do you have other preventative maintenance services that we need to perform on a periodic basis which should be included in line items 0001 and 0002?\nANSWER: All preventative maintenance such as; shimming, replacing astragals, replacing /repairing exit hardware, etc. shall be covered under line items 3.3 and 3.4\n\nCan you please provide a copy of the most recent life safety drawing referenced in the solicitation so we can review door locations?\nANSWER: YES, Attached\nCan you please provide copies of the most recent door inspection reports for both fire-rated and non-fire rated doors?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification. Non-fire doors are not inspected by the contractor.\n\nIn regards to the Manchester VA door inspection and repair service request for quote - how many doors do we carry for the $150 repair charge ?Â All 1000 doors ?Â So a total of $150,000.00 for line itemÂ 4.Â And if I read it correctly, if the cost of material/parts exceeds $150 per door, to issue a detailed change order ?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door.\nThe solicitation references approximately 135 fire doors for inspection, but the pricing schedule lists CLIN 0004 with a quantity of 1,000 doors. Additionally, the Performance Work Statement indicates that contractors should carry $150 in materials per door.\nCould you please clarify the intended basis for pricing CLIN 0004?\n\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.\nSpecifically, should offerors carry:\n$150 Ã— 1,000 doors ($150,000), based on the quantity shown in the pricing schedule, or\n$150 Ã— approximately 135 doors (approximately $20,250), based on the stated number of fire doors in the facility inventory?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24126Q0497","place_of_performance":{"zip":"03104","city":{"name":"Manchester"},"state":{"code":"NH"},"street":"Manchester VA Medical Center 718 Smyth Road","country":{"code":"USA"}},"product_service_code":"J042"},{"dates":{"posted":"2026-09-09","posted_at":"2026-09-09T15:27:33.178Z","created_at":"2026-09-09T15:27:33.178Z","modified_at":"2026-09-09T15:27:33.178Z","response_deadline":{"raw":"2026-07-02T15:00:00-04:00","utc":"2026-07-02T19:00:00Z","date":"2026-07-02","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/671f91f7e4ef4fcea3af0393944c1641/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"J042--Door Inspections and Repair Service Contract","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-09","archive_type":"auto_custom"},"history":[{"index":8,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:42:36.910Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"cba945de8afb420794de453f0a427da0","solicitation_number":"36C24126P0643","related_opportunity_id":"671f91f7e4ef4fcea3af0393944c1641"},{"index":7,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":6,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:46.185Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"3bda2571f43c494eb3fbc14dc08da82a","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":4,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-06-24T20:10:37.617Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"09d88714ec5a4550a4980f4f2177439b","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":3,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:55:15.034Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"03ffaa2252df43daa68090eaad34594e","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:51:55.672Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"0377e6b3fc0f495dae7a41080cc3aecb","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-05-15T17:39:11.402Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"03798b450615493fb5e0d5943e679d8c","solicitation_number":"36C24126Q0497"}],"contacts":[{"name":"Shawn Lawrence","role":"primary","email":"Shawn.Lawrence@va.gov","phone":"203-932-5711","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"671f91f7e4ef4fcea3af0393944c1641","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"03798b450615493fb5e0d5943e679d8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-16T13:03:54.013459960Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"a3c023d4c84ec7a530b0f35892df9cd91bd40b3a54780a9a4df898a34dbd0e2b","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"description":{"html":"RFI Sol# 36C24126Q0497 - Fire/Doors Inspection and Repairs\n\nWho currently conducts monthly, quarterly or annual routine inspection, preventative maintenance on the 865 non-fire doors? Â i.e. External contractor or VA staff?Â \n\nANSWER: The non-fire doors are inspected in house. As part of the contract these doors will continue to be inspected in house. We may request the contractor make repairs to these doors as needed utilizing funds from CLINs 3.3(Labor) and 3.4(materials)\n\nFire Doors are the only doors that are required to be inspected by the contractor and for the contractor to provide a report for. Repairs to these doors shall also utilize CLINs 3.3(Labor) and 3.4(materials)\n\nThe scope of the SOW seems to exclude routine inspection or maintenance on the non-fire doors, and covers only procurement of material and parts for those 865 doors.Â  Please can you confirm this.Â \n\nANSWER: That is correct. See response to RFI 1\n\nIn relation to the labor cost for installation of the material and parts for the non-fire doors - which CLIN line does this pull from or can this labor cost be billed separately?\nANSWER: Non-Fire doors and Fire door labor hours for repairs are under CLIN 3.3 STAND BY SERVICES   160 hours. All hours for INSPECTIONS AND REPORTS are billed under CLINS 3.1 and 3.2\nIs the annual parts and material line item of $150,000 per year for 1000 doors to be inserted in the CLIN by the contractor or left blank for the VA to include?Â Â \n\nANSWER: Parts and Materials are part of CLIN 3.4 MATERIALS and PARTS    All Material and parts as listed in CLIN 3.4 are part of the contract and are bid at time of contract. 1,000 doors at $150 per door to cover incidental repairs for all 1000 doors (Fire and Non-Fire doors) LABOR is part of CLIN 3.3\n\nWho is the current/incumbent awardee and what is the existing contract number.\nANSWER: Current awardee is Diversified Site Services. Contract is up for rebid as contract period of performance has expired. Other contractors in the past have been Door Innovations and DH Pace. \nFire/smoke doors are typically inspected annually, specifically for the VA and Joint Commission. Can you please explain why this solicitation requires inspections on a quarterly basis? This is 4 times the amount of work that is required by code, or are you asking for Â¼ of the fire/smoke doors (~34 doors) inspected each quarter?\n\nANSWER: We experienced repairs that were getting documented as corrections to fire doors only to fail on the next annual inspection. While we agree that it is only required once per year, the previous failures of repairs and compliance has lead us to require it quarterly. \nIs the $150 per door a pre-determined Government NTE that should be entered into the price schedule, or is it a hard cap for individual repairs? To ensure all offers are evaluated the same for this line item, can you clarify how offerors should price CLIN 0004 (leave it blank, use $150,000, NSP, etc.)?\nANSWER: See response to RFI #4. Bid as 1000 doors at $150 per door. \nHow will emergency calls outside of the stated normal business hours (0700 to 1630) be billed? Should offerors include an after-hours/overtime labor rate in addition to the standard stand-by rate? \nANSWER: Emergency calls and 4-hour response time is EXCLUDED from this contract. It was an inadvertent carry-over from another service contract. All calls/communication SHALL NOT be required to be addressed within a four-hour response time. The expectation is that a response shall be provided within a week and work scheduled from there.\n\nDoes the VA have a current and accurate inventory document, or does the offeror have to create one from scratch?\n\nANSWER: The VA has an accurate and current inventory and status report. At the time of bidding the VA is 92% compliant with all doors and expected to be at 100% compliance before bid award.  Offeror shall be provided a list of fire doors and locations at the start of the contract to build into a report\n\nSection 1.0 Introduction states to provide inspection and maintenance services on all 1000 doors to include 135 fire doors, but the entire scope of work section appears to be only focused on fire rated doors. Can you please explain the services being requested on the non-fire rated doors? NFPA 80 does not cover inspection requirement for non-fire rated doors, and the scope of work (Section 3.0) currently doesn t define specific tasks for non-fire rated door inspections.\nAre we required only to provide repairs on non-fire/smoke rated doors?\nANSWER: Services being request on non-fire doors are covered by line items 3.3 and 3.4 and answered under RFI #1. Contractor to inspect fire doors and provide report this is covered under 3.1 and 3.2. \n\nNon-Fire doors are inspected internally by VA Staff. Repairs to fire doors and non Fire doors are covered under 3.3 and 3.4. See RFI #1 for additional clarification. \n\nDo you have a checklist for non-fire rated door inspections?\nANSWER: No inspection of NON-FIRE rated doors is required by the contractor.\nAre these door quantities of approximately 1000 total and 135 for fire/smoke doors all single leaf swinging doors, or are there double leaf doors (please specify how many double leaf doors)?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nAre there any other types of fire rated doors such as horizontal sliders, drop or roll down doors, etc.? If so, can you please provide a more detailed quantity of doors identifying how many of each type so we can ensure we provide an accurate price.\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nThe scope of work mentions preventative maintenance services. Can you please confirm the preventative maintenance services are the  Standby Service Call Hours  reserved in the supplies and services table for any maintenance work needed?\nOr do you have other preventative maintenance services that we need to perform on a periodic basis which should be included in line items 0001 and 0002?\nANSWER: All preventative maintenance such as; shimming, replacing astragals, replacing /repairing exit hardware, etc. shall be covered under line items 3.3 and 3.4\n\nCan you please provide a copy of the most recent life safety drawing referenced in the solicitation so we can review door locations?\nANSWER: YES, Attached\nCan you please provide copies of the most recent door inspection reports for both fire-rated and non-fire rated doors?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification. Non-fire doors are not inspected by the contractor.\n\n In regards to the Manchester VA door inspection and repair service request for quote - how many doors do we carry for the $150 repair charge ?Â  All 1000 doors ?Â  So a total of $150,000.00 for line itemÂ 4.Â  And if I read it correctly, if the cost of material/parts exceeds $150 per door, to issue a detailed change order ?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door.\nThe solicitation references approximately 135 fire doors for inspection, but the pricing schedule lists CLIN 0004 with a quantity of 1,000 doors. Additionally, the Performance Work Statement indicates that contractors should carry $150 in materials per door.\nCould you please clarify the intended basis for pricing CLIN 0004?\n\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.\nSpecifically, should offerors carry:\n$150 Ã— 1,000 doors ($150,000), based on the quantity shown in the pricing schedule, or \n$150 Ã— approximately 135 doors (approximately $20,250), based on the stated number of fire doors in the facility inventory? \nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.","text":"RFI Sol# 36C24126Q0497 - Fire/Doors Inspection and Repairs\n\nWho currently conducts monthly, quarterly or annual routine inspection, preventative maintenance on the 865 non-fire doors? Â i.e. External contractor or VA staff?Â\n\nANSWER: The non-fire doors are inspected in house. As part of the contract these doors will continue to be inspected in house. We may request the contractor make repairs to these doors as needed utilizing funds from CLINs 3.3(Labor) and 3.4(materials)\n\nFire Doors are the only doors that are required to be inspected by the contractor and for the contractor to provide a report for. Repairs to these doors shall also utilize CLINs 3.3(Labor) and 3.4(materials)\n\nThe scope of the SOW seems to exclude routine inspection or maintenance on the non-fire doors, and covers only procurement of material and parts for those 865 doors.Â Please can you confirm this.Â\n\nANSWER: That is correct. See response to RFI 1\n\nIn relation to the labor cost for installation of the material and parts for the non-fire doors - which CLIN line does this pull from or can this labor cost be billed separately?\nANSWER: Non-Fire doors and Fire door labor hours for repairs are under CLIN 3.3 STAND BY SERVICES 160 hours. All hours for INSPECTIONS AND REPORTS are billed under CLINS 3.1 and 3.2\nIs the annual parts and material line item of $150,000 per year for 1000 doors to be inserted in the CLIN by the contractor or left blank for the VA to include?Â Â\n\nANSWER: Parts and Materials are part of CLIN 3.4 MATERIALS and PARTS All Material and parts as listed in CLIN 3.4 are part of the contract and are bid at time of contract. 1,000 doors at $150 per door to cover incidental repairs for all 1000 doors (Fire and Non-Fire doors) LABOR is part of CLIN 3.3\n\nWho is the current/incumbent awardee and what is the existing contract number.\nANSWER: Current awardee is Diversified Site Services. Contract is up for rebid as contract period of performance has expired. Other contractors in the past have been Door Innovations and DH Pace.\nFire/smoke doors are typically inspected annually, specifically for the VA and Joint Commission. Can you please explain why this solicitation requires inspections on a quarterly basis? This is 4 times the amount of work that is required by code, or are you asking for Â¼ of the fire/smoke doors (~34 doors) inspected each quarter?\n\nANSWER: We experienced repairs that were getting documented as corrections to fire doors only to fail on the next annual inspection. While we agree that it is only required once per year, the previous failures of repairs and compliance has lead us to require it quarterly.\nIs the $150 per door a pre-determined Government NTE that should be entered into the price schedule, or is it a hard cap for individual repairs? To ensure all offers are evaluated the same for this line item, can you clarify how offerors should price CLIN 0004 (leave it blank, use $150,000, NSP, etc.)?\nANSWER: See response to RFI #4. Bid as 1000 doors at $150 per door.\nHow will emergency calls outside of the stated normal business hours (0700 to 1630) be billed? Should offerors include an after-hours/overtime labor rate in addition to the standard stand-by rate?\nANSWER: Emergency calls and 4-hour response time is EXCLUDED from this contract. It was an inadvertent carry-over from another service contract. All calls/communication SHALL NOT be required to be addressed within a four-hour response time. The expectation is that a response shall be provided within a week and work scheduled from there.\n\nDoes the VA have a current and accurate inventory document, or does the offeror have to create one from scratch?\n\nANSWER: The VA has an accurate and current inventory and status report. At the time of bidding the VA is 92% compliant with all doors and expected to be at 100% compliance before bid award. Offeror shall be provided a list of fire doors and locations at the start of the contract to build into a report\n\nSection 1.0 Introduction states to provide inspection and maintenance services on all 1000 doors to include 135 fire doors, but the entire scope of work section appears to be only focused on fire rated doors. Can you please explain the services being requested on the non-fire rated doors? NFPA 80 does not cover inspection requirement for non-fire rated doors, and the scope of work (Section 3.0) currently doesn t define specific tasks for non-fire rated door inspections.\nAre we required only to provide repairs on non-fire/smoke rated doors?\nANSWER: Services being request on non-fire doors are covered by line items 3.3 and 3.4 and answered under RFI #1. Contractor to inspect fire doors and provide report this is covered under 3.1 and 3.2.\n\nNon-Fire doors are inspected internally by VA Staff. Repairs to fire doors and non Fire doors are covered under 3.3 and 3.4. See RFI #1 for additional clarification.\n\nDo you have a checklist for non-fire rated door inspections?\nANSWER: No inspection of NON-FIRE rated doors is required by the contractor.\nAre these door quantities of approximately 1000 total and 135 for fire/smoke doors all single leaf swinging doors, or are there double leaf doors (please specify how many double leaf doors)?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nAre there any other types of fire rated doors such as horizontal sliders, drop or roll down doors, etc.? If so, can you please provide a more detailed quantity of doors identifying how many of each type so we can ensure we provide an accurate price.\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nThe scope of work mentions preventative maintenance services. Can you please confirm the preventative maintenance services are the Standby Service Call Hours reserved in the supplies and services table for any maintenance work needed?\nOr do you have other preventative maintenance services that we need to perform on a periodic basis which should be included in line items 0001 and 0002?\nANSWER: All preventative maintenance such as; shimming, replacing astragals, replacing /repairing exit hardware, etc. shall be covered under line items 3.3 and 3.4\n\nCan you please provide a copy of the most recent life safety drawing referenced in the solicitation so we can review door locations?\nANSWER: YES, Attached\nCan you please provide copies of the most recent door inspection reports for both fire-rated and non-fire rated doors?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification. Non-fire doors are not inspected by the contractor.\n\nIn regards to the Manchester VA door inspection and repair service request for quote - how many doors do we carry for the $150 repair charge ?Â All 1000 doors ?Â So a total of $150,000.00 for line itemÂ 4.Â And if I read it correctly, if the cost of material/parts exceeds $150 per door, to issue a detailed change order ?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door.\nThe solicitation references approximately 135 fire doors for inspection, but the pricing schedule lists CLIN 0004 with a quantity of 1,000 doors. Additionally, the Performance Work Statement indicates that contractors should carry $150 in materials per door.\nCould you please clarify the intended basis for pricing CLIN 0004?\n\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.\nSpecifically, should offerors carry:\n$150 Ã— 1,000 doors ($150,000), based on the quantity shown in the pricing schedule, or\n$150 Ã— approximately 135 doors (approximately $20,250), based on the stated number of fire doors in the facility inventory?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24126Q0497","place_of_performance":{"zip":"03104","city":{"name":"Manchester"},"state":{"code":"NH"},"street":"Manchester VA Medical Center 718 Smyth Road","country":{"code":"USA"}},"product_service_code":"J042"},{"award":{"date":"2026-09-09","amount":"981180.00","number":"36C24126P0643","awardee":{"raw":"HurtVet Subcontracting, Inc. Heber City UT 84032 USA","uei":"LJLDFKJ2VKP5","cage":"5MB43","name":"HurtVet Subcontracting, Inc.","location":{"zip":"84032","city":{"code":"34310","name":"Heber City"},"state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-09-09","posted_at":"2026-09-09T15:42:36.910Z","award_date":"2026-09-09","created_at":"2026-09-09T15:39:02.816Z","modified_at":"2026-09-09T15:42:36.917Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/cba945de8afb420794de453f0a427da0/view"},"naics":{"codes":["541350"],"primary":"541350"},"title":"J042--Door Inspections and Repair Service Contract","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-10-09","archive_type":"auto_custom"},"history":[{"index":2,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:42:36.910Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"cba945de8afb420794de453f0a427da0","solicitation_number":"36C24126P0643","related_opportunity_id":"671f91f7e4ef4fcea3af0393944c1641"},{"index":1,"title":"J042--Door Inspections and Repair Service Contract","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-09T15:27:33.178Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"671f91f7e4ef4fcea3af0393944c1641","solicitation_number":"36C24126Q0497","parent_opportunity_id":"03798b450615493fb5e0d5943e679d8c"}],"contacts":[{"name":"Shawn Lawrence","role":"primary","email":"Shawn.Lawrence@va.gov","phone":"203-932-5711","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"cba945de8afb420794de453f0a427da0","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"03798b450615493fb5e0d5943e679d8c","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T02:24:18.424666942Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"fef8f960220e7c31e27f4374f08735be06f24b1b634c76b7a5ac2a5c45ab0557","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"36C24126P0643","place_of_performance":{"zip":"03104","city":{"name":"Manchester"},"state":{"code":"NH"},"country":{"code":"USA"}},"product_service_code":"J042"}],"due_at":"2026-07-02T19:00:00Z","due_date":"2026-07-02","closes_at":"2026-07-02T19:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","state":"NH","county":"33011","county_name":"Hillsborough County","city":"3345140","city_name":"Manchester","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"LJLDFKJ2VKP5","amount":"981180.00","linked_awards":7,"cancelled":false,"archived":true,"updated_at":"2026-10-10T06:24:47.015975Z","principal_notice_id":"671f91f7e4ef4fcea3af0393944c1641","description":{"text":"RFI Sol# 36C24126Q0497 - Fire/Doors Inspection and Repairs\n\nWho currently conducts monthly, quarterly or annual routine inspection, preventative maintenance on the 865 non-fire doors? Â i.e. External contractor or VA staff?Â\n\nANSWER: The non-fire doors are inspected in house. As part of the contract these doors will continue to be inspected in house. We may request the contractor make repairs to these doors as needed utilizing funds from CLINs 3.3(Labor) and 3.4(materials)\n\nFire Doors are the only doors that are required to be inspected by the contractor and for the contractor to provide a report for. Repairs to these doors shall also utilize CLINs 3.3(Labor) and 3.4(materials)\n\nThe scope of the SOW seems to exclude routine inspection or maintenance on the non-fire doors, and covers only procurement of material and parts for those 865 doors.Â Please can you confirm this.Â\n\nANSWER: That is correct. See response to RFI 1\n\nIn relation to the labor cost for installation of the material and parts for the non-fire doors - which CLIN line does this pull from or can this labor cost be billed separately?\nANSWER: Non-Fire doors and Fire door labor hours for repairs are under CLIN 3.3 STAND BY SERVICES 160 hours. All hours for INSPECTIONS AND REPORTS are billed under CLINS 3.1 and 3.2\nIs the annual parts and material line item of $150,000 per year for 1000 doors to be inserted in the CLIN by the contractor or left blank for the VA to include?Â Â\n\nANSWER: Parts and Materials are part of CLIN 3.4 MATERIALS and PARTS All Material and parts as listed in CLIN 3.4 are part of the contract and are bid at time of contract. 1,000 doors at $150 per door to cover incidental repairs for all 1000 doors (Fire and Non-Fire doors) LABOR is part of CLIN 3.3\n\nWho is the current/incumbent awardee and what is the existing contract number.\nANSWER: Current awardee is Diversified Site Services. Contract is up for rebid as contract period of performance has expired. Other contractors in the past have been Door Innovations and DH Pace.\nFire/smoke doors are typically inspected annually, specifically for the VA and Joint Commission. Can you please explain why this solicitation requires inspections on a quarterly basis? This is 4 times the amount of work that is required by code, or are you asking for Â¼ of the fire/smoke doors (~34 doors) inspected each quarter?\n\nANSWER: We experienced repairs that were getting documented as corrections to fire doors only to fail on the next annual inspection. While we agree that it is only required once per year, the previous failures of repairs and compliance has lead us to require it quarterly.\nIs the $150 per door a pre-determined Government NTE that should be entered into the price schedule, or is it a hard cap for individual repairs? To ensure all offers are evaluated the same for this line item, can you clarify how offerors should price CLIN 0004 (leave it blank, use $150,000, NSP, etc.)?\nANSWER: See response to RFI #4. Bid as 1000 doors at $150 per door.\nHow will emergency calls outside of the stated normal business hours (0700 to 1630) be billed? Should offerors include an after-hours/overtime labor rate in addition to the standard stand-by rate?\nANSWER: Emergency calls and 4-hour response time is EXCLUDED from this contract. It was an inadvertent carry-over from another service contract. All calls/communication SHALL NOT be required to be addressed within a four-hour response time. The expectation is that a response shall be provided within a week and work scheduled from there.\n\nDoes the VA have a current and accurate inventory document, or does the offeror have to create one from scratch?\n\nANSWER: The VA has an accurate and current inventory and status report. At the time of bidding the VA is 92% compliant with all doors and expected to be at 100% compliance before bid award. Offeror shall be provided a list of fire doors and locations at the start of the contract to build into a report\n\nSection 1.0 Introduction states to provide inspection and maintenance services on all 1000 doors to include 135 fire doors, but the entire scope of work section appears to be only focused on fire rated doors. Can you please explain the services being requested on the non-fire rated doors? NFPA 80 does not cover inspection requirement for non-fire rated doors, and the scope of work (Section 3.0) currently doesn t define specific tasks for non-fire rated door inspections.\nAre we required only to provide repairs on non-fire/smoke rated doors?\nANSWER: Services being request on non-fire doors are covered by line items 3.3 and 3.4 and answered under RFI #1. Contractor to inspect fire doors and provide report this is covered under 3.1 and 3.2.\n\nNon-Fire doors are inspected internally by VA Staff. Repairs to fire doors and non Fire doors are covered under 3.3 and 3.4. See RFI #1 for additional clarification.\n\nDo you have a checklist for non-fire rated door inspections?\nANSWER: No inspection of NON-FIRE rated doors is required by the contractor.\nAre these door quantities of approximately 1000 total and 135 for fire/smoke doors all single leaf swinging doors, or are there double leaf doors (please specify how many double leaf doors)?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nAre there any other types of fire rated doors such as horizontal sliders, drop or roll down doors, etc.? If so, can you please provide a more detailed quantity of doors identifying how many of each type so we can ensure we provide an accurate price.\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nThe scope of work mentions preventative maintenance services. Can you please confirm the preventative maintenance services are the Standby Service Call Hours reserved in the supplies and services table for any maintenance work needed?\nOr do you have other preventative maintenance services that we need to perform on a periodic basis which should be included in line items 0001 and 0002?\nANSWER: All preventative maintenance such as; shimming, replacing astragals, replacing /repairing exit hardware, etc. shall be covered under line items 3.3 and 3.4\n\nCan you please provide a copy of the most recent life safety drawing referenced in the solicitation so we can review door locations?\nANSWER: YES, Attached\nCan you please provide copies of the most recent door inspection reports for both fire-rated and non-fire rated doors?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification. Non-fire doors are not inspected by the contractor.\n\nIn regards to the Manchester VA door inspection and repair service request for quote - how many doors do we carry for the $150 repair charge ?Â All 1000 doors ?Â So a total of $150,000.00 for line itemÂ 4.Â And if I read it correctly, if the cost of material/parts exceeds $150 per door, to issue a detailed change order ?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door.\nThe solicitation references approximately 135 fire doors for inspection, but the pricing schedule lists CLIN 0004 with a quantity of 1,000 doors. Additionally, the Performance Work Statement indicates that contractors should carry $150 in materials per door.\nCould you please clarify the intended basis for pricing CLIN 0004?\n\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.\nSpecifically, should offerors carry:\n$150 Ã— 1,000 doors ($150,000), based on the quantity shown in the pricing schedule, or\n$150 Ã— approximately 135 doors (approximately $20,250), based on the stated number of fire doors in the facility inventory?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.","html":"RFI Sol# 36C24126Q0497 - Fire/Doors Inspection and Repairs\n\nWho currently conducts monthly, quarterly or annual routine inspection, preventative maintenance on the 865 non-fire doors? Â i.e. External contractor or VA staff?Â \n\nANSWER: The non-fire doors are inspected in house. As part of the contract these doors will continue to be inspected in house. We may request the contractor make repairs to these doors as needed utilizing funds from CLINs 3.3(Labor) and 3.4(materials)\n\nFire Doors are the only doors that are required to be inspected by the contractor and for the contractor to provide a report for. Repairs to these doors shall also utilize CLINs 3.3(Labor) and 3.4(materials)\n\nThe scope of the SOW seems to exclude routine inspection or maintenance on the non-fire doors, and covers only procurement of material and parts for those 865 doors.Â  Please can you confirm this.Â \n\nANSWER: That is correct. See response to RFI 1\n\nIn relation to the labor cost for installation of the material and parts for the non-fire doors - which CLIN line does this pull from or can this labor cost be billed separately?\nANSWER: Non-Fire doors and Fire door labor hours for repairs are under CLIN 3.3 STAND BY SERVICES   160 hours. All hours for INSPECTIONS AND REPORTS are billed under CLINS 3.1 and 3.2\nIs the annual parts and material line item of $150,000 per year for 1000 doors to be inserted in the CLIN by the contractor or left blank for the VA to include?Â Â \n\nANSWER: Parts and Materials are part of CLIN 3.4 MATERIALS and PARTS    All Material and parts as listed in CLIN 3.4 are part of the contract and are bid at time of contract. 1,000 doors at $150 per door to cover incidental repairs for all 1000 doors (Fire and Non-Fire doors) LABOR is part of CLIN 3.3\n\nWho is the current/incumbent awardee and what is the existing contract number.\nANSWER: Current awardee is Diversified Site Services. Contract is up for rebid as contract period of performance has expired. Other contractors in the past have been Door Innovations and DH Pace. \nFire/smoke doors are typically inspected annually, specifically for the VA and Joint Commission. Can you please explain why this solicitation requires inspections on a quarterly basis? This is 4 times the amount of work that is required by code, or are you asking for Â¼ of the fire/smoke doors (~34 doors) inspected each quarter?\n\nANSWER: We experienced repairs that were getting documented as corrections to fire doors only to fail on the next annual inspection. While we agree that it is only required once per year, the previous failures of repairs and compliance has lead us to require it quarterly. \nIs the $150 per door a pre-determined Government NTE that should be entered into the price schedule, or is it a hard cap for individual repairs? To ensure all offers are evaluated the same for this line item, can you clarify how offerors should price CLIN 0004 (leave it blank, use $150,000, NSP, etc.)?\nANSWER: See response to RFI #4. Bid as 1000 doors at $150 per door. \nHow will emergency calls outside of the stated normal business hours (0700 to 1630) be billed? Should offerors include an after-hours/overtime labor rate in addition to the standard stand-by rate? \nANSWER: Emergency calls and 4-hour response time is EXCLUDED from this contract. It was an inadvertent carry-over from another service contract. All calls/communication SHALL NOT be required to be addressed within a four-hour response time. The expectation is that a response shall be provided within a week and work scheduled from there.\n\nDoes the VA have a current and accurate inventory document, or does the offeror have to create one from scratch?\n\nANSWER: The VA has an accurate and current inventory and status report. At the time of bidding the VA is 92% compliant with all doors and expected to be at 100% compliance before bid award.  Offeror shall be provided a list of fire doors and locations at the start of the contract to build into a report\n\nSection 1.0 Introduction states to provide inspection and maintenance services on all 1000 doors to include 135 fire doors, but the entire scope of work section appears to be only focused on fire rated doors. Can you please explain the services being requested on the non-fire rated doors? NFPA 80 does not cover inspection requirement for non-fire rated doors, and the scope of work (Section 3.0) currently doesn t define specific tasks for non-fire rated door inspections.\nAre we required only to provide repairs on non-fire/smoke rated doors?\nANSWER: Services being request on non-fire doors are covered by line items 3.3 and 3.4 and answered under RFI #1. Contractor to inspect fire doors and provide report this is covered under 3.1 and 3.2. \n\nNon-Fire doors are inspected internally by VA Staff. Repairs to fire doors and non Fire doors are covered under 3.3 and 3.4. See RFI #1 for additional clarification. \n\nDo you have a checklist for non-fire rated door inspections?\nANSWER: No inspection of NON-FIRE rated doors is required by the contractor.\nAre these door quantities of approximately 1000 total and 135 for fire/smoke doors all single leaf swinging doors, or are there double leaf doors (please specify how many double leaf doors)?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nAre there any other types of fire rated doors such as horizontal sliders, drop or roll down doors, etc.? If so, can you please provide a more detailed quantity of doors identifying how many of each type so we can ensure we provide an accurate price.\nANSWER: A previous report is provided and attached for FIRE DOOR clarification\nThe scope of work mentions preventative maintenance services. Can you please confirm the preventative maintenance services are the  Standby Service Call Hours  reserved in the supplies and services table for any maintenance work needed?\nOr do you have other preventative maintenance services that we need to perform on a periodic basis which should be included in line items 0001 and 0002?\nANSWER: All preventative maintenance such as; shimming, replacing astragals, replacing /repairing exit hardware, etc. shall be covered under line items 3.3 and 3.4\n\nCan you please provide a copy of the most recent life safety drawing referenced in the solicitation so we can review door locations?\nANSWER: YES, Attached\nCan you please provide copies of the most recent door inspection reports for both fire-rated and non-fire rated doors?\nANSWER: A previous report is provided and attached for FIRE DOOR clarification. Non-fire doors are not inspected by the contractor.\n\n In regards to the Manchester VA door inspection and repair service request for quote - how many doors do we carry for the $150 repair charge ?Â  All 1000 doors ?Â  So a total of $150,000.00 for line itemÂ 4.Â  And if I read it correctly, if the cost of material/parts exceeds $150 per door, to issue a detailed change order ?\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door.\nThe solicitation references approximately 135 fire doors for inspection, but the pricing schedule lists CLIN 0004 with a quantity of 1,000 doors. Additionally, the Performance Work Statement indicates that contractors should carry $150 in materials per door.\nCould you please clarify the intended basis for pricing CLIN 0004?\n\nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.\nSpecifically, should offerors carry:\n$150 Ã— 1,000 doors ($150,000), based on the quantity shown in the pricing schedule, or \n$150 Ã— approximately 135 doors (approximately $20,250), based on the stated number of fire doors in the facility inventory? \nANSWER: Contractor to carry material allowance of $150,000 in CLIN 0004. 1000 doors at $150 per door. This is for fire doors and non-fire door repairs.","origin":"detail"},"contacts":[{"name":"Shawn Lawrence","role":"primary","email":"Shawn.Lawrence@va.gov","phone":"203-932-5711","title":"Contract Specialist"}],"place_of_performance":{"zip":"03104","city":{"name":"Manchester"},"state":{"code":"NH"},"street":"Manchester VA Medical Center 718 Smyth Road","country":{"code":"USA"}},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"naics_codes":["541350"],"award":null,"attachments":[{"resource_id":"b7925506db984bcc884349e2228e0037","name":"36C24126P0643_1.docx","kind":"file","mime_type":".docx","size_bytes":22848,"posted_at":"2026-09-09T15:42:36.910Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b7925506db984bcc884349e2228e0037/download","mirrored":false},{"resource_id":"7851a99b3ee14af3a6695f469300272f","name":"Attachment 1 FAR 52.212-1.pdf","kind":"file","mime_type":".pdf","size_bytes":151448,"posted_at":"2026-05-15T17:39:11.402Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/7851a99b3ee14af3a6695f469300272f/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24126P0643_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24126P0643_3600_-NONE-_-NONE-/","piid":"36C24126P0643","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"LJLDFKJ2VKP5","recipient_name":"HURTVET SUBCONTRACTING, INC.","recipient_uei":"LJLDFKJ2VKP5","recipient_cage":"5MB43","recipient_city":"HEBER CITY","recipient_state":"UT","sub_name":"Department of Veterans Affairs","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","office_key":"o-36C241","first_action_date":"2026-09-09","last_action_date":"2026-09-09","actions":1,"obligated":"194052.00","current_total_value":"194052.00","potential_total_value":"981180.00","naics":"541350","psc":"J042","extent_competed":"COMPETED UNDER SAP","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":8,"description":"DOOR INSPECTIONS AND REPAIR SERVICE CONTRACT","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24126Q0497 equals the FPDS solicitation identifier","same awarding office 36C241"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24127Q0084","latest_notice_id":"939b8f3021be4a75ae5972b0c7ffb9ae","title":"X1EA--CWM VA Police Use of shooting range.","solicitation_number":"36C24127Q0084","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"611699","psc":"X1EA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24127Q0017","latest_notice_id":"d60676ea33af4051b90a1953ab55743e","title":"S201--36C24127Q0017 Windows Washing Service Amendment 0002","solicitation_number":"36C24127Q0017","notice_type":"k","first_type":"k","first_posted":"2026-10-26","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"561720","psc":"S201","set_aside":"SDVOSBC","state":"MA","county":"25017","county_name":"Middlesex County","city":"2501704615","city_name":"Bedford","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24127Q0044","latest_notice_id":"a2f2fe28c1ec4687b2a2955cf947935e","title":"9140--Togus Fuel Oil and Diesel Delivery","solicitation_number":"36C24127Q0044","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"324110","psc":"9140","set_aside":"SBA","state":"ME","county":"23011","county_name":"Kennebec County","city":"2302100","city_name":"Augusta","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24127Q0076","latest_notice_id":"bb30bc78067840a082b5d9e12eceddd2","title":"Q601--Sources sought Boston Medical Coding Period of Period 01/01/2027-04/01/2027","solicitation_number":"36C24127Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541219","psc":"Q601","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24127Q0030","latest_notice_id":"10c3d2d3d0c543179707f8cc9448f701","title":"J061--Eaton Powerware System Replacement","solicitation_number":"36C24127Q0030","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J061","set_aside":"SDVOSBC","state":"NH","county":"33011","county_name":"Hillsborough County","city":"3345140","city_name":"Manchester","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"36C25526Q0617","latest_notice_id":"3506983a2af048deaf442eae0f8b8a04","title":"H112--Annual/Sem-i annual fire smoke inspections and auto door services l EKH","solicitation_number":"36C25526Q0617","notice_type":"o","first_type":"r","first_posted":"2026-08-19","last_posted":"2026-11-18","notices":11,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C255","office_name":"255-NETWORK CONTRACT OFFICE 15 (36C255)","naics":"541350","psc":"H112","set_aside":"SBA","state":"KS","county":"20103","county_name":"Leavenworth County","city":"2039000","city_name":"Leavenworth","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C25727Q00310002","latest_notice_id":"c463c6aa97b7496d99268a3c961117de","title":"NTX Elevator Inspection - Amendment","solicitation_number":"36C25727Q0031-0002","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-04","notices":1,"due_at":"2026-11-30T21:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"541350","psc":"J036","set_aside":"SDVOSBC","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"140RR027Q0064","latest_notice_id":"98bb064f93a4474eaef326d5aebcf419","title":"Z--Elevator Inspection and Certification Services","solicitation_number":"140RR027Q0064","notice_type":"r","first_type":"r","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-12-03T18:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1425","sub_name":"BUREAU OF RECLAMATION","office_key":"o-140R20","office_name":"MP-REGIONAL OFFICE","naics":"541350","psc":"Z1PZ","set_aside":null,"state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"ON SERVICES FOR ELEVATORS LOCATED AT FOLSOM DAM","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"}],"similar_open_total":12,"indexable":false}