{"canonical":"https://sealedbidder.com/opportunities/36c24126q0434","key":"36C24126Q0434","url":"https://sealedbidder.com/opportunities/36c24126q0434","title":"K063--Crescent House EST4 Fire Alarm Upgrade","solicitation_number":"36C24126Q0434","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-05-06T16:00:00Z","first_posted":"2026-04-20","last_posted":"2026-04-30","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"561621","psc":"K063","set_aside":"SDVOSBC","place_state":"MA","place_scope":"site","site":"Bedford VA Medical Center","place_state_source":null,"place_evidence":null,"place_county":"25017","place_county_name":"Middlesex County","place_city":"2501704615","place_city_name":"Bedford","winner":"BOISSONNEAULT ELECTRIC CORP","award_amount":null,"publications":[{"notice_id":"76521c5d95994394b327fc483d258227","title":"K063--Crescent House EST4 Fire Alarm Upgrade Bedford VA Medical Center","solicitation_number":"36C24126Q0434","notice_type":"k","base_type":"k","posted":"2026-04-20","posted_at":"2026-04-20T11:30:43.067Z","due_at":"2026-05-01T16:00:00Z","due_date":"2026-05-01","cancelled":false,"archived":true,"archive_date":"2026-05-16","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/76521c5d95994394b327fc483d258227/view","enriched":true,"history":[{"index":3,"title":"K063--Crescent House EST4 Fire Alarm Upgrade","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-30T17:17:48.234Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"caea56e47f264519be3bca492955d4b7","solicitation_number":"36C24126Q0434","parent_opportunity_id":"76521c5d95994394b327fc483d258227"},{"index":1,"title":"K063--Crescent House EST4 Fire Alarm Upgrade Bedford VA Medical Center","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T11:30:43.067Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"76521c5d95994394b327fc483d258227","solicitation_number":"36C24126Q0434"}]},{"notice_id":"caea56e47f264519be3bca492955d4b7","title":"K063--Crescent House EST4 Fire Alarm Upgrade","solicitation_number":"36C24126Q0434","notice_type":"k","base_type":"k","posted":"2026-04-30","posted_at":"2026-04-30T17:17:48.234Z","due_at":"2026-05-06T16:00:00Z","due_date":"2026-05-06","cancelled":false,"archived":true,"archive_date":"2026-05-21","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/caea56e47f264519be3bca492955d4b7/view","enriched":true,"history":[{"index":3,"title":"K063--Crescent House EST4 Fire Alarm Upgrade","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-30T17:17:48.234Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"caea56e47f264519be3bca492955d4b7","solicitation_number":"36C24126Q0434","parent_opportunity_id":"76521c5d95994394b327fc483d258227"},{"index":1,"title":"K063--Crescent House EST4 Fire Alarm Upgrade Bedford VA Medical Center","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T11:30:43.067Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"76521c5d95994394b327fc483d258227","solicitation_number":"36C24126Q0434"}]}],"latest_notice_id":"caea56e47f264519be3bca492955d4b7","first_type":"k","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-04-20","posted_at":"2026-04-20T11:30:43.067Z","created_at":"2026-04-20T11:30:38.610Z","modified_at":"2026-05-22T04:04:30.698Z","response_deadline":{"raw":"2026-05-01T12:00:00-04:00","utc":"2026-05-01T16:00:00Z","date":"2026-05-01","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/76521c5d95994394b327fc483d258227/view"},"naics":{"codes":["561621"],"primary":"561621"},"title":"K063--Crescent House EST4 Fire Alarm Upgrade Bedford VA Medical Center","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-16","archive_type":"auto_custom"},"history":[{"index":3,"title":"K063--Crescent House EST4 Fire Alarm Upgrade","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-30T17:17:48.234Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"caea56e47f264519be3bca492955d4b7","solicitation_number":"36C24126Q0434","parent_opportunity_id":"76521c5d95994394b327fc483d258227"},{"index":1,"title":"K063--Crescent House EST4 Fire Alarm Upgrade Bedford VA Medical Center","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T11:30:43.067Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"76521c5d95994394b327fc483d258227","solicitation_number":"36C24126Q0434"}],"contacts":[{"name":"Yolanda Rankin","role":"primary","email":"yolanda.rankin@va.gov","phone":"978-890-2709","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"76521c5d95994394b327fc483d258227","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"76521c5d95994394b327fc483d258227","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T09:15:14.651059618Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"1807fe45a3c4973cdec834bd3ad265c2b7f75d850c0f30c0e9480246183d8bc9","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T09:15:14.651059618Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"2\n\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6,  Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services,  as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ.  The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01, dated 3/13/2026.\n\nThis solicitation is set-aside for SDVOSBs.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 561621, with a small business size standard of $25.0 million.\nThe FSC/PSC is K063.\n\nThe Bedford VA Medical center located at 200 Springs Rd in Bedford, MA 01730 is seeking to purchase services to complete the Fire Alarm Upgrade at the Crescent House. Wage Determination 2015-4047 is applicable. \n\n\n\nStatement of Work (SOW)\n\nCrescent House: EST4 Fire Alarm System Upgrade\n\n1. Project Overview\n\nThis Statement of Work outlines the requirements for upgrading the existing fire alarm system at Crescent House Transitional Residence Program located at 15 Veterans Way, Lowell, MA 01852. The Crescent House Transitional Residence Program building is a three-story apartment type complex housing approximately 40 Veterans. The apartments are broken down into multi-bedroom units (2-4 per Unit) that share living room kitchens. The facility has 22 units with approximately 40 bedrooms. The first-floor units are single story units. The second floor has kitchens and living rooms with 1-2 bedrooms. The remainder of the bedrooms are on the third floor. The units are also connected to the adjacent units through doors/hallways on the second and third floors. There are common area smoke detectors, manual pull stations and monitor points for sprinkler flow and tamper switches. The apartments have smoke detectors with sounder bases. The panel communicates directly to the fire department via a Keltron Wireless Radio box.  \n\nThe government is looking to upgrade the existing Edwards EST3 System to the more modernized EST4 system. The upgrade will include new battery installation of the primary system back-up batteries and the attached booster box batteries. There is a remote annunciator in the facilities main office that will also be replaced/upgraded. Replace existing devices in apartment 110 to be included in the upgrade. The new system must provide compliance with all relevant codes and VA standards. All services listed in this SOW are what the government is purchasing for the contracted price. All work stated in this SOW will be completed for the contracted price at no additional cost to the government. This is a Firm-Fixed Price contract without modification. Any work stated in this SOW will be completed by the contractor for the contracted price decided prior to signing the contract by the contractor. \n\n2. Objectives/Work to Complete \n\nReplace the current fire alarm control panel and all internal components with contractor supplied Edwards EST4 system and internal components. Reuse of backbox is acceptable if desired and a new door is installed on the cabinet.\nReuse of all field initiating devices and fully operational wiring is expected, minus the devices in apt 110 mentioned below to be replaced.\nInstall/mount a contractor supplied small fire alarm panel storage cabinet for as-builts and fire alarm system software in the same location as the main panel.\nReplace the remote annunciator with a contractor supplying the new annunciator and backbox in the main office.\nReplace the system main back-up batteries with contractor supplied (2) 12V / 26Ah AGM Flame Retardant batteries, equivalent or greater. Replace batteries only. (see Attachment A)\nInstall contractor supplied Fire Sprinkler Head Spare box in the same room as the main panel/fire sprinkler system water supply room. The box will also contain (6) contractor supplied new sprinkler heads. Replacement type of similar brand, quality, style, rating of sprinklers currently installed at the Crescent House. (One type only of primary style currently installed). The box will also contain a contractor supplied Sprinkler Head Wrench to fit the type of sprinkler heads that are stored in the Fire Sprinkler Head Spare box.\nReplace the system booster box back-up batteries (2) 12V / 8Ah AGM Flame Retardant batteries, equivalent or greater. Replace batteries only. (see Attachment A)\nUpdate all programming necessary to complete the upgrade to leave the panel and system with no warnings, alerts, troubles, or faults at no additional cost to the government.\nReplace all fire alarm system devices in apartment 110: \nNon-Addressable Smoke Detectors   3\nAddressable Smoke Detectors   2\nAddressable Pull Stations   2\nHorn-Strobe with Speaker   5\n(existing units to be replaced with identical units for uniformity)\nTroubleshoot and repair wiring, hardware, software issues related to system problems foreseen or unforeseen to include clearing known MAP fault. (up to 10 hrs if needed)\nConnect existing NAC circuits to the new fire alarm system.\nEnsure compliance with all National Fire Protection Agency codes to include NFPA 72, VA Fire Protection Design Manual, and local authority having jurisdiction (AHJ) requirements.\nAll wiring and connections will be neat and orderly. The wiring inside the panel will be properly bundled and run in straight direct lines. Solid wire connections will be made to avoid  pig-tailing  wires with wire nuts inside the panel. New wires will be run inside the panel if necessary to avoid this at no additional cost to the government.\nMinimize disruption to building occupants and operations during upgrade.\n\n3. Existing System\n\nThe main panel is in a large open area mechanical/electrical/service room with a lot of space to work. The panel is mounted on the outside of a plywood wall, and all immediate components have easy access to all elements of the panel. (see Attachment A)\nThe main panel is an addressable Edwards EST 3-CAB5R Complete Cabinet (Red), (Rev. 14), Mfg: week 47/2003 with two addressable loops.\nThe remote annunciator is an Edwards EST 3-RLCM/D, (Rev. 4), Mfg: 01/2022. (See Attachment A)\n\nThe system currently consists of approximately:\nNon-Addressable Smoke Detectors   77\nAddressable Smoke Detectors   34\nAddressable Pull Stations   23\nExterior Rotating Beacon   1\nHorn Strobe w/speaker   120\nSprinkler flow switch\nSprinkler Tamper Switch with attached modules\n\nScope of Work\n\nA. Site Assessment\nConduct a pre-installation survey to verify current fire alarm system configuration, device locations, and building layouts.\nIdentify areas requiring extra coverage or any unique installation considerations.\nB. Design & Submittals\nPrepare detailed shop drawings, device layout, wiring diagrams, and sequence of operations with timelines of work to completion and contract closeout.\nSubmit plans for VA and AHJ review/approval before commencement.\n\nC. Equipment & Materials\nContractor Supplied brand new:\nEdwards EST4 fire alarm control panel and all required internal and external components\nEdwards EST4 compatible remote command module (remote annunciator) and backbox\nFire Alarm initiating devices for apartment 110 detectors, modules, pull stations, notification devices (see list above)\nMain panel back-up batteries (UL flame rated)\nBooster Panel back-up batteries (UL flame rated)\nFire alarm panel storage cabinet. The cabinet will be red, comply with current NFPA codes, and be made of durable steel   minimum 20-22 gage\nFire sprinkler spare head box with (6) spare sprinkler heads and sprinkler head wrench. The cabinet will be red, comply with current NFPA codes, and be made of durable steel   minimum 20-22 gage \nNOTE: All equipment must be UL-listed, NFPA Code Compliant, and compatible with the Edwards EST4 system.\n\nD. Installation\nRemove and dispose of the existing fire alarm control panel and any obsolete hardware safely and completely.\nInstall EST4 system and all associated field devices as per the approved design.\nEnsure all wiring is in accordance with NEC and VA standards.\nCoordinate with related trades (e.g., IT for networking, electrical for power) as required.\nE. Testing & Commissioning\nComplete successful I/O point-to-point testing.\nComplete full functional testing as per NFPA and VA requirements.\nProvide documentation of testing and as-built drawings.\nF. Training & Documentation\nTrain local facility staff on system operation, troubleshooting, and basic maintenance.\nProvide all user manuals and training documents.\nG. Warranty & Support\nMinimum one-year warranty on all equipment and installation labor to include all reused/reinstalled equipment components.\nProvide post-installation technical support by contract terms.\n4. Deliverables\nDetailed design drawings and device lists.\nSubmittal documents for VA/AHJ approval.\nEST4 system installed and fully operational with zero faults, alerts, troubles, or errors verified by VA Contract COR.\nTesting/commissioning reports and as-built documentation.\nTraining sessions and manuals for facility staff.\n5. Schedule\nKick-off & Assessment:Â Within 2 weeks of notice to proceed.\nDesign/Submittals:Â 3-4 weeks.\nInstallation:Â 4-6 weeks upon submittal approval.\nTesting & Training:Â 1 week.\nTotal estimated duration: 8-12 weeks.\n6. Standards & Reference Material\nNational Fire Protection Association (NFPA 72)\nVA Fire Protection Design Manual\nLocal codes and AHJ requirements\nEST4 System Manufacturer Guides\n7. Roles & Responsibilities\nContractor:Â Responsible for site assessments, design, installation, testing, training, and support.\nVA/Crescent House:Â Responsible for providing site access, facilitating coordination, and reviewing submittals.\nVA Project Manager/COR: Responsible for project oversight, acceptance of project completed work, and verification of project satisfactory completion. \n8. Acceptance Criteria\nEST4 system fully operational with no deficiencies, system faults, troubles, alerts, or problems.\nAll installed equipment defects free with all work areas cleaned up and no visible remaining signs from construction remaining.\nAll wiring neat and orderly, all necessary labels installed, all covers closed, all screws installed, all junction boxes closed with no visible wiring shown.\nAll tests completed and required documentation turned over and accepted by VA authority, AHJ and project COR.\nFacility staff trained.\n10. General Provisions\nAll work to comply with VA sensitive data handling and site privacy requirements.\nAll workers adhere to Crescent House safety and security regulations.\nEnd of Statement of Work\n\nAttachment A\n\n\n\n\n\nThe purchase order/contract period of performance is 12 weeks. \nPlace of Performance/Place of Delivery\nAddress:\nCrescent House Transitional Residence Program \n15 Veterans Way \nLowell, MA \n\nPostal Code:\n01852\nCountry:\nUNITED STATES\n\n\nThe following solicitation provisions apply to this acquisition:\nFAR 52.212-1,  Instructions to Offerors Commercial Products and Commercial Services  \nFAR 52.212-3,  Offerors Representations and Certifications Commercial Products and Commercial Services  \n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/ in accordance with FAR 52.212-3,  Offerors Representations and Certifications Commercial Products and Commercial Services.  If paragraph (j) of the provision is applicable, a written submission is required.\n\nFAR 52.212-2 Evaluation-Commercial Products and Commercial Services [In accordance with FAR 12.301(c) when the use of evaluation factors is appropriate, the contracting officer may (1)Â Insert the provision atÂ 52.212-2, Evaluation-Commercial ProductsÂ andÂ Commercial Services, inÂ solicitationsÂ forÂ commercial productsÂ orÂ commercial servicesÂ (seeÂ 12.602); or (2)Â Include a similar provision containing all evaluation factors required byÂ 13.106,Â subpartÂ  14.2Â orÂ subpartÂ  15.3, as an addendum (seeÂ 12.302(d)).]\n\n52.225-2 Buy American Certificate.(OCT 2022)\n\nAs prescribed in 25.1101(a)(2), insert the following provision:\n(a) (1) The Offeror certifies that each end product, except those listed in paragraph (b) of this provision, is a domestic end product and that each domestic end product listed in paragraph (c) of this provision contains a critical component.\n\n(2) The Offeror shall list as foreign end products those end products manufactured in the United States that do not qualify as domestic end products. For those foreign end products that do not consist wholly or predominantly of iron or steel or a combination of both, the Offeror shall also indicate whether these foreign end products exceed 55 percent domestic content, except for those that are COTS items. If the percentage of the domestic content is unknown, select  no .\n\n(3) The Offeror shall separately list the line item numbers of domestic end products that contain a critical component (see FAR 25.105).\n\n(4) The terms  commercially available off-the-shelf (COTS) item,   critical component,  \"domestic end product,\" \"end product,\" and \"foreign end product\" are defined in the clause of this solicitation entitled \"Buy American-Supplies.\"\n\n(b)Foreign End Products:\n\n\n(c)Â DomesticÂ end productsÂ containing a criticalÂ component:\nLine ItemÂ No.Â ___\n(d)Â The Government will evaluateÂ offersÂ in accordance with the policies and procedures ofÂ partÂ  25Â of the FederalÂ AcquisitionÂ Regulation.\n(End of provision)\n\nAs prescribed in 852.102(a), insert the following provision:\n\nSolicitation Provisions or Clauses Incorporated by Reference (JAN 2008)\n\nThe following provisions or clauses incorporated by reference in this solicitation must be completed by the offeror or prospective contractor and submitted with the quotation or offer. Copies of these provisions or clauses are available on the Internet at the Web sites provided in the provision at FAR 52.252-1, Solicitation Provisions Incorporated by Reference, or the clause at FAR 52.252-2, Clauses Incorporated by Reference. Copies may also be obtained from the contracting officer.\n\n[Contracting officer shall list all FAR and 48 CFR Chapter 8 (VAAR) provisions and clauses incorporated by reference that must be completed by the offeror or prospective contractor and submitted with the quotation or offer.]\n\n(End of provision)\n\n852.219-76 VA Notice of Limitations on Subcontracting   Certificate of Compliance for Supplies and Products (JAN 2023) (DEVIATION)\n\nAs prescribed in 819.7011(c), insert the following clause. The contracting officer shall tailor the clause in paragraph (a)(2)(iii) as appropriate:\n(iii)   The offeror certifies that it will supply the end item of a small business manufacturer, processor, or producer made in the United States, unless a waiver as provided in 13 CFR 121.406(b)(5) has been issued by SBA.\n\nCertification\nI hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror].\nPrinted Name of Signee:\nPrinted Title of Signee:\nSignature:\nDate:\nCompany Name and Address:\n(End of clause)\nParent topic:Â Subpart 852.2 - Text of Provisions and Clauses\n\n52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998).\nAs prescribed in 52.107(a), insert the following provision:\n\nThis solicitation incorporates one or more solicitation provisions by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. The offeror is cautioned that the listed provisions may include blocks that must be completed by the offeror and submitted with its quotation or offer. In lieu of submitting the full text of those provisions, the offeror may identify the provision by paragraph identifier and provide the appropriate information with its quotation or offer. Also, the full text of a solicitation provision may be accessed electronically at this/these address(es):\nhttps://www.acquisition.gov/browse/index/far.\n\n\n52.252-2 Clauses Incorporated by Reference (FEB 1998).\nThis contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):\nhttps://www.acquisition.gov/browse/index/far.\n\nThe following contract clauses apply to this acquisition: \n52.204-7 System for Award Management Registration (DEVIATION NOV 2025).\n52.209-10 Prohibition on Contracting With Inverted Domestic Corporations. (DEVIATION NOV 2025).\n52.219-33 Nonmanufacturer Rule (SEP 2021).\n52.203-18 Prohibition on Contracting with Entities (JAN 2018).\n52.233-3 Protest after Award (DEVIATION NOV 2025).\n52.233-4 Applicable Law for Breach of Contract Claim (DEVIATION NOV 2025).\n52.244-6 Subcontracts for Commercial Products and Commercial Services. (DEVIATION NOV 2025).\n852.204-70 Personal Identity Verification of Contractor Personnel (MAY 2020).\n852.219-73  VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses (JAN 2023) (DEVIATION).\n852.223-71 Safety and Health (SEP 2019).\n852.232-72  Electronic Submission of Payment Requests (NOV 2018).\n852.246-71  Rejected Goods (OCT 2018)\n52.212-4  Contract Terms and Conditions Commercial Products and Commercial Services  (DEVIATION AUG 2025).\n\nThe following subparagraphs of FAR 52.212-5 are applicable:\n52.219-27, Notice of Set-Aside for, or Sole-Source Award to, Service-Disabled Veteran-Owned Small Business (SDVOSB) Concerns Eligible Under the SDVOSB Program (Feb 2024).\n52.222-3 Convict Labor (June 2003).\n52.222-21 Prohibition of Segregated Facilities (APR 2015).\n52.222-26 Equal Opportunity (SEPT 2016).\n52.222-35 Equal Opportunity for Veterans (JUN 2020).\n52.222-36 Equal Opportunity for Workers with Disabilities (Jun 2020).\n52.222-37 Employment Reports on Veterans (Jun 2020).\n52.222-41 Service Contract Labor Standards (AUG 2018).\n52.222-42 Statement of Equivalent Rates for Federal Hires (MAY 2014).\n52.222-50 Combating Trafficking in Persons (Oct 2025).\n52.222-54 Employment Eligibility Verification (Jan 2025).\n52.222-44, Fair Labor Standards Act and Service Contract Labor Standards-Price Adjustment (May 2014).\n52.222-55 Minimum Wages for Contractor Workers Under Executive Order 14026 (Jan 2022).\n52.222-62 Paid Sick Leave Under Executive Order 13706 (Jan 2022).\n52.225-1 Buy American-Supplies (Oct 2022).\n52.225-13 Restrictions on Certain Foreign Purchases (Feb 2021).\n52.226-8 Encouraging Contractor Policies to Ban Text Messaging While Driving (May 2024).\n52.232-33 Payment by Electronic Funds Transfer-System for Award Management (Oct2018).\n52.242-5 Payments to Small Business Subcontractors (Jan 2017).\n52.203-13 Contractor Code of Business Ethics and Conduct (Nov 2021).\n52.203-17 Contractor Employee Whistleblower Rights (Nov 2023).\n52.203-19 Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements (Jan 2017).\n52.204-23 Prohibition onÂ ContractingÂ for Hardware, Software, and Services Developed or Provided by Kaspersky Lab Covered EntitiesÂ (Dec 2023).\n52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment. (Nov 2021).\n\n \nSAM: Interested parties shall be registered in System for Award Management (SAM) as prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling 1-866-606-8220. Interested parties not registered in SAM in sufficient time to meet the VA s requirement will be ineligible to receive a government contract. This determination will be at the discretion of the Contracting Officer.\n\nSystem updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations, including 52.223-22, Public Disclosure of Greenhouse Gas Emissions and Reduction Goals Representation, and paragraph (t) of 52.212-3, Offeror Representations and Certifications  Commercial Products and Commercial Services. \n\nThe VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract. This determination will be at the discretion of the Contracting Officer. Interested parties with no prior VA contracts can apply here:Â https://www.cep.fsc.va.gov/\n\nAll quoters shall submit the following: \nAttachment 1- Price Schedule\nAttachment 2 - Past Performance Worksheet \n\nAll quotes shall be sent to the Contract Specialist, Yolanda Rankin\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13.  Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.   \n\nThe following are the decision factors:\nPrice (Follow these instructions):\nOfferor shall complete Attachment 1 - Price Schedule, with offerors proposed contract line item prices inserted in appropriate spaces.Â  \nPast Performance:\nOfferor shall utilize Attachment 2   Past Performance Worksheet to provide at least one (1) but no more than (3) references of work, similar in scope and size with the requirement detailed in the (Performance Work Statement).  References may be checked by the Contracting Officer to ensure your company is capable of performing the Statement of Work.Â  The Government also reserves the right to obtain information for use in the evaluation of past performance from any and all sources. \nTechnical: The offeror s quote shall be evaluated to determine if the organization has the experience and capabilities to provide the requested services IAW the (Performance Work Statement) in a timely efficient manner.Â \nContractor shall demonstrate their corporate experience and approach to meet all requirements stated in the (Performance Work Statement).\nContractor shall demonstrate that their technicians meet the qualification standards stated in the (Performance Work Statement).\n\nThe award will be made to the response most advantageous to the Government.\nResponses should contain your best terms, conditions.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\n Quoters shall list exception(s) and rationale for the exception(s), if any.\nQuestions shall be submitted to the Contracting Officer in writing via e-mail at yolanda.rankin@ va.gov.  Oral questions are not acceptable due to the possibility of misunderstanding or misinterpretation. The cut-off date and time for receipt of questions is 27-Apr- 2026 by 4:00 PM EST.  Questions received after this date and time may not be answered.  Questions shall be answered in a formal amendment to the solicitation so all interested parties can see the answers. \nA site visit is planned for 23-April-2026 at 10:30AM. We will meet at the main entrance of the Crescent House Transitional Residence Program located at 15 Veterans Way, Lowell, MA 01852. \nSubmission of your response shall be received not later than 1-May-2026 by 12pm. RFQ responses must be submitted via email to: Yolanda.Rankin@va.gov.  Hand deliveries shall not be accepted.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).  \nPoint of Contact\nYolanda Rankin\nYolanda.Rankin@va.gov\n\nATTACHMENT 1\nPRICE SCHEDULE\n\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\nLabor\n1\nJB\n$________________\n$_________________\n0002\nMaterial\n1\nJB\n$________________\n$_________________\n0003\nTroubleshooting\n10  \nHR\n$________________\n$_________________\n\n\n\nGRAND TOTAL\n$_________________\n\n\n\n\n\n\n\n\nATTACHMENT 2\nPAST PERFORMANCE WORKSHEET\n1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization:\n2. Contracting Activity Address:\n3. Contract Number:\n4. Date of Contract Award:\n5. Beginning Date of Contract:\n6. Completion Date of Contract:\n7. Contract Value:\n8. Type of Contract:\n9a. Technical Point of Contact: \n9b. Contracting Point of Contact:\nName:\nName:\nTitle:\nTitle:\nAddress:\nAddress:\nTelephone:\nTelephone:\nEmail:\nEmail:\n10. Place of Performance:\n11. Description of Work (Use a continuation sheet if necessary):\n12. List any commendations or awards received: \n13. List of Major Subcontractors:\n\n\nPAST PERFORMANCE WORKSHEET\n1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization:\n2. Contracting Activity Address:\n3. Contract Number:\n4. Date of Contract Award:\n5. Beginning Date of Contract:\n6. Completion Date of Contract:\n7. Contract Value:\n8. Type of Contract:\n9a. Technical Point of Contact: \n9b. Contracting Point of Contact:\nName:\nName:\nTitle:\nTitle:\nAddress:\nAddress:\nTelephone:\nTelephone:\nEmail:\nEmail:\n10. Place of Performance:\n11. Description of Work (Use a continuation sheet if necessary):\n12. List any commendations or awards received: \n13. List of Major Subcontractors:\n\n\n\nPAST PERFORMANCE WORKSHEET\n1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization:\n2. Contracting Activity Address:\n3. Contract Number:\n4. Date of Contract Award:\n5. Beginning Date of Contract:\n6. Completion Date of Contract:\n7. Contract Value:\n8. Type of Contract:\n9a. Technical Point of Contact: \n9b. Contracting Point of Contact:\nName:\nName:\nTitle:\nTitle:\nAddress:\nAddress:\nTelephone:\nTelephone:\nEmail:\nEmail:\n10. Place of Performance:\n11. Description of Work (Use a continuation sheet if necessary):\n12. List any commendations or awards received: \n13. List of Major Subcontractors:","text":"2\n\nDescription\nThis is a combined synopsis/solicitation for commercial products and commercial services prepared in accordance with the format in Federal Acquisition Regulation (FAR) subpart 12.6, Streamlined Procedures for Evaluation and Solicitation for Commercial Products and Commercial Services, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested, and a written solicitation document will not be issued.\n\nThis solicitation is issued as an RFQ. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2026-01, dated 3/13/2026.\n\nThis solicitation is set-aside for SDVOSBs.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 561621, with a small business size standard of $25.0 million.\nThe FSC/PSC is K063.\n\nThe Bedford VA Medical center located at 200 Springs Rd in Bedford, MA 01730 is seeking to purchase services to complete the Fire Alarm Upgrade at the Crescent House. Wage Determination 2015-4047 is applicable.\n\nStatement of Work (SOW)\n\nCrescent House: EST4 Fire Alarm System Upgrade\n\n1. Project Overview\n\nThis Statement of Work outlines the requirements for upgrading the existing fire alarm system at Crescent House Transitional Residence Program located at 15 Veterans Way, Lowell, MA 01852. The Crescent House Transitional Residence Program building is a three-story apartment type complex housing approximately 40 Veterans. The apartments are broken down into multi-bedroom units (2-4 per Unit) that share living room kitchens. The facility has 22 units with approximately 40 bedrooms. The first-floor units are single story units. The second floor has kitchens and living rooms with 1-2 bedrooms. The remainder of the bedrooms are on the third floor. The units are also connected to the adjacent units through doors/hallways on the second and third floors. There are common area smoke detectors, manual pull stations and monitor points for sprinkler flow and tamper switches. The apartments have smoke detectors with sounder bases. The panel communicates directly to the fire department via a Keltron Wireless Radio box.\n\nThe government is looking to upgrade the existing Edwards EST3 System to the more modernized EST4 system. The upgrade will include new battery installation of the primary system back-up batteries and the attached booster box batteries. There is a remote annunciator in the facilities main office that will also be replaced/upgraded. Replace existing devices in apartment 110 to be included in the upgrade. The new system must provide compliance with all relevant codes and VA standards. All services listed in this SOW are what the government is purchasing for the contracted price. All work stated in this SOW will be completed for the contracted price at no additional cost to the government. This is a Firm-Fixed Price contract without modification. Any work stated in this SOW will be completed by the contractor for the contracted price decided prior to signing the contract by the contractor.\n\n2. Objectives/Work to Complete\n\nReplace the current fire alarm control panel and all internal components with contractor supplied Edwards EST4 system and internal components. Reuse of backbox is acceptable if desired and a new door is installed on the cabinet.\nReuse of all field initiating devices and fully operational wiring is expected, minus the devices in apt 110 mentioned below to be replaced.\nInstall/mount a contractor supplied small fire alarm panel storage cabinet for as-builts and fire alarm system software in the same location as the main panel.\nReplace the remote annunciator with a contractor supplying the new annunciator and backbox in the main office.\nReplace the system main back-up batteries with contractor supplied (2) 12V / 26Ah AGM Flame Retardant batteries, equivalent or greater. Replace batteries only. (see Attachment A)\nInstall contractor supplied Fire Sprinkler Head Spare box in the same room as the main panel/fire sprinkler system water supply room. The box will also contain (6) contractor supplied new sprinkler heads. Replacement type of similar brand, quality, style, rating of sprinklers currently installed at the Crescent House. (One type only of primary style currently installed). The box will also contain a contractor supplied Sprinkler Head Wrench to fit the type of sprinkler heads that are stored in the Fire Sprinkler Head Spare box.\nReplace the system booster box back-up batteries (2) 12V / 8Ah AGM Flame Retardant batteries, equivalent or greater. Replace batteries only. (see Attachment A)\nUpdate all programming necessary to complete the upgrade to leave the panel and system with no warnings, alerts, troubles, or faults at no additional cost to the government.\nReplace all fire alarm system devices in apartment 110:\nNon-Addressable Smoke Detectors 3\nAddressable Smoke Detectors 2\nAddressable Pull Stations 2\nHorn-Strobe with Speaker 5\n(existing units to be replaced with identical units for uniformity)\nTroubleshoot and repair wiring, hardware, software issues related to system problems foreseen or unforeseen to include clearing known MAP fault. (up to 10 hrs if needed)\nConnect existing NAC circuits to the new fire alarm system.\nEnsure compliance with all National Fire Protection Agency codes to include NFPA 72, VA Fire Protection Design Manual, and local authority having jurisdiction (AHJ) requirements.\nAll wiring and connections will be neat and orderly. The wiring inside the panel will be properly bundled and run in straight direct lines. Solid wire connections will be made to avoid pig-tailing wires with wire nuts inside the panel. New wires will be run inside the panel if necessary to avoid this at no additional cost to the government.\nMinimize disruption to building occupants and operations during upgrade.\n\n3. Existing System\n\nThe main panel is in a large open area mechanical/electrical/service room with a lot of space to work. The panel is mounted on the outside of a plywood wall, and all immediate components have easy access to all elements of the panel. (see Attachment A)\nThe main panel is an addressable Edwards EST 3-CAB5R Complete Cabinet (Red), (Rev. 14), Mfg: week 47/2003 with two addressable loops.\nThe remote annunciator is an Edwards EST 3-RLCM/D, (Rev. 4), Mfg: 01/2022. (See Attachment A)\n\nThe system currently consists of approximately:\nNon-Addressable Smoke Detectors 77\nAddressable Smoke Detectors 34\nAddressable Pull Stations 23\nExterior Rotating Beacon 1\nHorn Strobe w/speaker 120\nSprinkler flow switch\nSprinkler Tamper Switch with attached modules\n\nScope of Work\n\nA. Site Assessment\nConduct a pre-installation survey to verify current fire alarm system configuration, device locations, and building layouts.\nIdentify areas requiring extra coverage or any unique installation considerations.\nB. Design & Submittals\nPrepare detailed shop drawings, device layout, wiring diagrams, and sequence of operations with timelines of work to completion and contract closeout.\nSubmit plans for VA and AHJ review/approval before commencement.\n\nC. Equipment & Materials\nContractor Supplied brand new:\nEdwards EST4 fire alarm control panel and all required internal and external components\nEdwards EST4 compatible remote command module (remote annunciator) and backbox\nFire Alarm initiating devices for apartment 110 detectors, modules, pull stations, notification devices (see list above)\nMain panel back-up batteries (UL flame rated)\nBooster Panel back-up batteries (UL flame rated)\nFire alarm panel storage cabinet. The cabinet will be red, comply with current NFPA codes, and be made of durable steel minimum 20-22 gage\nFire sprinkler spare head box with (6) spare sprinkler heads and sprinkler head wrench. The cabinet will be red, comply with current NFPA codes, and be made of durable steel minimum 20-22 gage\nNOTE: All equipment must be UL-listed, NFPA Code Compliant, and compatible with the Edwards EST4 system.\n\nD. Installation\nRemove and dispose of the existing fire alarm control panel and any obsolete hardware safely and completely.\nInstall EST4 system and all associated field devices as per the approved design.\nEnsure all wiring is in accordance with NEC and VA standards.\nCoordinate with related trades (e.g., IT for networking, electrical for power) as required.\nE. Testing & Commissioning\nComplete successful I/O point-to-point testing.\nComplete full functional testing as per NFPA and VA requirements.\nProvide documentation of testing and as-built drawings.\nF. Training & Documentation\nTrain local facility staff on system operation, troubleshooting, and basic maintenance.\nProvide all user manuals and training documents.\nG. Warranty & Support\nMinimum one-year warranty on all equipment and installation labor to include all reused/reinstalled equipment components.\nProvide post-installation technical support by contract terms.\n4. Deliverables\nDetailed design drawings and device lists.\nSubmittal documents for VA/AHJ approval.\nEST4 system installed and fully operational with zero faults, alerts, troubles, or errors verified by VA Contract COR.\nTesting/commissioning reports and as-built documentation.\nTraining sessions and manuals for facility staff.\n5. Schedule\nKick-off & Assessment:Â Within 2 weeks of notice to proceed.\nDesign/Submittals:Â 3-4 weeks.\nInstallation:Â 4-6 weeks upon submittal approval.\nTesting & Training:Â 1 week.\nTotal estimated duration: 8-12 weeks.\n6. Standards & Reference Material\nNational Fire Protection Association (NFPA 72)\nVA Fire Protection Design Manual\nLocal codes and AHJ requirements\nEST4 System Manufacturer Guides\n7. Roles & Responsibilities\nContractor:Â Responsible for site assessments, design, installation, testing, training, and support.\nVA/Crescent House:Â Responsible for providing site access, facilitating coordination, and reviewing submittals.\nVA Project Manager/COR: Responsible for project oversight, acceptance of project completed work, and verification of project satisfactory completion.\n8. Acceptance Criteria\nEST4 system fully operational with no deficiencies, system faults, troubles, alerts, or problems.\nAll installed equipment defects free with all work areas cleaned up and no visible remaining signs from construction remaining.\nAll wiring neat and orderly, all necessary labels installed, all covers closed, all screws installed, all junction boxes closed with no visible wiring shown.\nAll tests completed and required documentation turned over and accepted by VA authority, AHJ and project COR.\nFacility staff trained.\n10. General Provisions\nAll work to comply with VA sensitive data handling and site privacy requirements.\nAll workers adhere to Crescent House safety and security regulations.\nEnd of Statement of Work\n\nAttachment A\n\nThe purchase order/contract period of performance is 12 weeks.\nPlace of Performance/Place of Delivery\nAddress:\nCrescent House Transitional Residence Program\n15 Veterans Way\nLowell, MA\n\nPostal Code:\n01852\nCountry:\nUNITED STATES\n\nThe following solicitation provisions apply to this acquisition:\nFAR 52.212-1, Instructions to Offerors Commercial Products and Commercial Services\nFAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services\n\nOfferors must complete annual representations and certifications electronically via the System for Award Management (SAM) website located at https://sam.gov/ in accordance with FAR 52.212-3, Offerors Representations and Certifications Commercial Products and Commercial Services. If paragraph (j) of the provision is applicable, a written submission is required.\n\nFAR 52.212-2 Evaluation-Commercial Products and Commercial Services [In accordance with FAR 12.301(c) when the use of evaluation factors is appropriate, the contracting officer may (1)Â Insert the provision atÂ 52.212-2, Evaluation-Commercial ProductsÂ andÂ Commercial Services, inÂ solicitationsÂ forÂ commercial productsÂ orÂ commercial servicesÂ (seeÂ 12.602); or (2)Â Include a similar provision containing all evaluation factors required byÂ 13.106,Â subpartÂ 14.2Â orÂ subpartÂ 15.3, as an addendum (seeÂ 12.302(d)).]\n\n52.225-2 Buy American Certificate.(OCT 2022)\n\nAs prescribed in 25.1101(a)(2), insert the following provision:\n(a) (1) The Offeror certifies that each end product, except those listed in paragraph (b) of this provision, is a domestic end product and that each domestic end product listed in paragraph (c) of this provision contains a critical component.\n\n(2) The Offeror shall list as foreign end products those end products manufactured in the United States that do not qualify as domestic end products. For those foreign end products that do not consist wholly or predominantly of iron or steel or a combination of both, the Offeror shall also indicate whether these foreign end products exceed 55 percent domestic content, except for those that are COTS items. If the percentage of the domestic content is unknown, select no .\n\n(3) The Offeror shall separately list the line item numbers of domestic end products that contain a critical component (see FAR 25.105).\n\n(4) The terms commercially available off-the-shelf (COTS) item, critical component, \"domestic end product,\" \"end product,\" and \"foreign end product\" are defined in the clause of this solicitation entitled \"Buy American-Supplies.\"\n\n(b)Foreign End Products:\n\n(c)Â DomesticÂ end productsÂ containing a criticalÂ component:\nLine ItemÂ No.Â ___\n(d)Â The Government will evaluateÂ offersÂ in accordance with the policies and procedures ofÂ partÂ 25Â of the FederalÂ AcquisitionÂ Regulation.\n(End of provision)\n\nAs prescribed in 852.102(a), insert the following provision:\n\nSolicitation Provisions or Clauses Incorporated by Reference (JAN 2008)\n\nThe following provisions or clauses incorporated by reference in this solicitation must be completed by the offeror or prospective contractor and submitted with the quotation or offer. Copies of these provisions or clauses are available on the Internet at the Web sites provided in the provision at FAR 52.252-1, Solicitation Provisions Incorporated by Reference, or the clause at FAR 52.252-2, Clauses Incorporated by Reference. Copies may also be obtained from the contracting officer.\n\n[Contracting officer shall list all FAR and 48 CFR Chapter 8 (VAAR) provisions and clauses incorporated by reference that must be completed by the offeror or prospective contractor and submitted with the quotation or offer.]\n\n(End of provision)\n\n852.219-76 VA Notice of Limitations on Subcontracting Certificate of Compliance for Supplies and Products (JAN 2023) (DEVIATION)\n\nAs prescribed in 819.7011(c), insert the following clause. The contracting officer shall tailor the clause in paragraph (a)(2)(iii) as appropriate:\n(iii) The offeror certifies that it will supply the end item of a small business manufacturer, processor, or producer made in the United States, unless a waiver as provided in 13 CFR 121.406(b)(5) has been issued by SBA.\n\nCertification\nI hereby certify that if awarded the contract, [insert name of offeror] will comply with the limitations on subcontracting specified in this clause and in the resultant contract. I further certify that I am authorized to execute this certification on behalf of [insert name of offeror].\nPrinted Name of Signee:\nPrinted Title of Signee:\nSignature:\nDate:\nCompany Name and Address:\n(End of clause)\nParent topic:Â Subpart 852.2 - Text of Provisions and Clauses\n\n52.252-1 Solicitation Provisions Incorporated by Reference (FEB 1998).\nAs prescribed in 52.107(a), insert the following provision:\n\nThis solicitation incorporates one or more solicitation provisions by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. The offeror is cautioned that the listed provisions may include blocks that must be completed by the offeror and submitted with its quotation or offer. In lieu of submitting the full text of those provisions, the offeror may identify the provision by paragraph identifier and provide the appropriate information with its quotation or offer. Also, the full text of a solicitation provision may be accessed electronically at this/these address(es):\nhttps://www.acquisition.gov/browse/index/far.\n\n52.252-2 Clauses Incorporated by Reference (FEB 1998).\nThis contract incorporates one or more clauses by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Also, the full text of a clause may be accessed electronically at this/these address(es):\nhttps://www.acquisition.gov/browse/index/far.\n\nThe following contract clauses apply to this acquisition:\n52.204-7 System for Award Management Registration (DEVIATION NOV 2025).\n52.209-10 Prohibition on Contracting With Inverted Domestic Corporations. (DEVIATION NOV 2025).\n52.219-33 Nonmanufacturer Rule (SEP 2021).\n52.203-18 Prohibition on Contracting with Entities (JAN 2018).\n52.233-3 Protest after Award (DEVIATION NOV 2025).\n52.233-4 Applicable Law for Breach of Contract Claim (DEVIATION NOV 2025).\n52.244-6 Subcontracts for Commercial Products and Commercial Services. (DEVIATION NOV 2025).\n852.204-70 Personal Identity Verification of Contractor Personnel (MAY 2020).\n852.219-73 VA Notice to Total Set-Aside for Certified Service-Disabled Veteran-Owned Small Businesses (JAN 2023) (DEVIATION).\n852.223-71 Safety and Health (SEP 2019).\n852.232-72 Electronic Submission of Payment Requests (NOV 2018).\n852.246-71 Rejected Goods (OCT 2018)\n52.212-4 Contract Terms and Conditions Commercial Products and Commercial Services (DEVIATION AUG 2025).\n\nThe following subparagraphs of FAR 52.212-5 are applicable:\n52.219-27, Notice of Set-Aside for, or Sole-Source Award to, Service-Disabled Veteran-Owned Small Business (SDVOSB) Concerns Eligible Under the SDVOSB Program (Feb 2024).\n52.222-3 Convict Labor (June 2003).\n52.222-21 Prohibition of Segregated Facilities (APR 2015).\n52.222-26 Equal Opportunity (SEPT 2016).\n52.222-35 Equal Opportunity for Veterans (JUN 2020).\n52.222-36 Equal Opportunity for Workers with Disabilities (Jun 2020).\n52.222-37 Employment Reports on Veterans (Jun 2020).\n52.222-41 Service Contract Labor Standards (AUG 2018).\n52.222-42 Statement of Equivalent Rates for Federal Hires (MAY 2014).\n52.222-50 Combating Trafficking in Persons (Oct 2025).\n52.222-54 Employment Eligibility Verification (Jan 2025).\n52.222-44, Fair Labor Standards Act and Service Contract Labor Standards-Price Adjustment (May 2014).\n52.222-55 Minimum Wages for Contractor Workers Under Executive Order 14026 (Jan 2022).\n52.222-62 Paid Sick Leave Under Executive Order 13706 (Jan 2022).\n52.225-1 Buy American-Supplies (Oct 2022).\n52.225-13 Restrictions on Certain Foreign Purchases (Feb 2021).\n52.226-8 Encouraging Contractor Policies to Ban Text Messaging While Driving (May 2024).\n52.232-33 Payment by Electronic Funds Transfer-System for Award Management (Oct2018).\n52.242-5 Payments to Small Business Subcontractors (Jan 2017).\n52.203-13 Contractor Code of Business Ethics and Conduct (Nov 2021).\n52.203-17 Contractor Employee Whistleblower Rights (Nov 2023).\n52.203-19 Prohibition on Requiring Certain Internal Confidentiality Agreements or Statements (Jan 2017).\n52.204-23 Prohibition onÂ ContractingÂ for Hardware, Software, and Services Developed or Provided by Kaspersky Lab Covered EntitiesÂ (Dec 2023).\n52.204-25 Prohibition on Contracting for Certain Telecommunications and Video Surveillance Services or Equipment. (Nov 2021).\n\nSAM: Interested parties shall be registered in System for Award Management (SAM) as prescribed in FAR Clause 52.232-33. SAM information can be obtained by accessing the internet at www.sam.gov or by calling 1-866-606-8220. Interested parties not registered in SAM in sufficient time to meet the VA s requirement will be ineligible to receive a government contract. This determination will be at the discretion of the Contracting Officer.\n\nSystem updates may lag policy updates. The System for Award Management (SAM) may continue to require entities to complete representations based on provisions that are not included in agency solicitations, including 52.223-22, Public Disclosure of Greenhouse Gas Emissions and Reduction Goals Representation, and paragraph (t) of 52.212-3, Offeror Representations and Certifications Commercial Products and Commercial Services.\n\nThe VA utilizes VISTA to issue a purchase order and liquidate invoices. Failure to register in VISTA may result in exclusion from the issuance of a VA contract. This determination will be at the discretion of the Contracting Officer. Interested parties with no prior VA contracts can apply here:Â https://www.cep.fsc.va.gov/\n\nAll quoters shall submit the following:\nAttachment 1- Price Schedule\nAttachment 2 - Past Performance Worksheet\n\nAll quotes shall be sent to the Contract Specialist, Yolanda Rankin\n\nAward will be based upon a comparative evaluation of quotes in accordance with the Simplified Acquisition Procedures of FAR 13. Comparative evaluation is the side by side pairwise comparison of quotes based on factors resulting in a Contracting Officer decision for the quote most favorable to the Government.\n\nThe following are the decision factors:\nPrice (Follow these instructions):\nOfferor shall complete Attachment 1 - Price Schedule, with offerors proposed contract line item prices inserted in appropriate spaces.Â\nPast Performance:\nOfferor shall utilize Attachment 2 Past Performance Worksheet to provide at least one (1) but no more than (3) references of work, similar in scope and size with the requirement detailed in the (Performance Work Statement). References may be checked by the Contracting Officer to ensure your company is capable of performing the Statement of Work.Â The Government also reserves the right to obtain information for use in the evaluation of past performance from any and all sources.\nTechnical: The offeror s quote shall be evaluated to determine if the organization has the experience and capabilities to provide the requested services IAW the (Performance Work Statement) in a timely efficient manner.Â\nContractor shall demonstrate their corporate experience and approach to meet all requirements stated in the (Performance Work Statement).\nContractor shall demonstrate that their technicians meet the qualification standards stated in the (Performance Work Statement).\n\nThe award will be made to the response most advantageous to the Government.\nResponses should contain your best terms, conditions.\n\nTo facilitate the award process, all quotes must include a statement regarding the terms and conditions herein as follows:\n\"The terms and conditions in the solicitation are acceptable to be included in the award document without modification, deletion, or addition.\"\nOR\n\"The terms and conditions in the solicitation are acceptable to be included in the award document with the exception, deletion, or addition of the following:\"\nQuoters shall list exception(s) and rationale for the exception(s), if any.\nQuestions shall be submitted to the Contracting Officer in writing via e-mail at yolanda.rankin@ va.gov. Oral questions are not acceptable due to the possibility of misunderstanding or misinterpretation. The cut-off date and time for receipt of questions is 27-Apr- 2026 by 4:00 PM EST. Questions received after this date and time may not be answered. Questions shall be answered in a formal amendment to the solicitation so all interested parties can see the answers.\nA site visit is planned for 23-April-2026 at 10:30AM. We will meet at the main entrance of the Crescent House Transitional Residence Program located at 15 Veterans Way, Lowell, MA 01852.\nSubmission of your response shall be received not later than 1-May-2026 by 12pm. RFQ responses must be submitted via email to: Yolanda.Rankin@va.gov. Hand deliveries shall not be accepted.\n\nLate submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f).\nPoint of Contact\nYolanda Rankin\nYolanda.Rankin@va.gov\n\nATTACHMENT 1\nPRICE SCHEDULE\n\nITEM NUMBER\nDESCRIPTION OF SUPPLIES/SERVICES\nQUANTITY\nUNIT\nUNIT PRICE\nAMOUNT\n0001\nLabor\n1\nJB\n$________________\n$_________________\n0002\nMaterial\n1\nJB\n$________________\n$_________________\n0003\nTroubleshooting\n10\nHR\n$________________\n$_________________\n\nGRAND TOTAL\n$_________________\n\nATTACHMENT 2\nPAST PERFORMANCE WORKSHEET\n1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization:\n2. Contracting Activity Address:\n3. Contract Number:\n4. Date of Contract Award:\n5. Beginning Date of Contract:\n6. Completion Date of Contract:\n7. Contract Value:\n8. Type of Contract:\n9a. Technical Point of Contact:\n9b. Contracting Point of Contact:\nName:\nName:\nTitle:\nTitle:\nAddress:\nAddress:\nTelephone:\nTelephone:\nEmail:\nEmail:\n10. Place of Performance:\n11. Description of Work (Use a continuation sheet if necessary):\n12. List any commendations or awards received:\n13. List of Major Subcontractors:\n\nPAST PERFORMANCE WORKSHEET\n1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization:\n2. Contracting Activity Address:\n3. Contract Number:\n4. Date of Contract Award:\n5. Beginning Date of Contract:\n6. Completion Date of Contract:\n7. Contract Value:\n8. Type of Contract:\n9a. Technical Point of Contact:\n9b. Contracting Point of Contact:\nName:\nName:\nTitle:\nTitle:\nAddress:\nAddress:\nTelephone:\nTelephone:\nEmail:\nEmail:\n10. Place of Performance:\n11. Description of Work (Use a continuation sheet if necessary):\n12. List any commendations or awards received:\n13. List of Major Subcontractors:\n\nPAST PERFORMANCE WORKSHEET\n1. Name of Contracting Activity, Government Agency, Commercial Firm or other Organization:\n2. Contracting Activity Address:\n3. Contract Number:\n4. Date of Contract Award:\n5. Beginning Date of Contract:\n6. Completion Date of Contract:\n7. Contract Value:\n8. Type of Contract:\n9a. Technical Point of Contact:\n9b. Contracting Point of Contact:\nName:\nName:\nTitle:\nTitle:\nAddress:\nAddress:\nTelephone:\nTelephone:\nEmail:\nEmail:\n10. Place of Performance:\n11. Description of Work (Use a continuation sheet if necessary):\n12. List any commendations or awards received:\n13. List of Major Subcontractors:","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24126Q0434","place_of_performance":{"street":"Crescent House Transitional Residence Program 15 Veterans Way","street2":"Lowell, MA 01852"},"product_service_code":"K063"},{"award":{"awardee":{}},"dates":{"posted":"2026-04-30","posted_at":"2026-04-30T17:17:48.234Z","created_at":"2026-04-30T17:17:42.736Z","modified_at":"2026-05-22T04:04:30.698Z","response_deadline":{"raw":"2026-05-06T12:00:00-04:00","utc":"2026-05-06T16:00:00Z","date":"2026-05-06","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/caea56e47f264519be3bca492955d4b7/view"},"naics":{"codes":["561621"],"primary":"561621"},"title":"K063--Crescent House EST4 Fire Alarm Upgrade","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-21","archive_type":"auto_custom"},"history":[{"index":3,"title":"K063--Crescent House EST4 Fire Alarm Upgrade","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-30T17:17:48.234Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"caea56e47f264519be3bca492955d4b7","solicitation_number":"36C24126Q0434","parent_opportunity_id":"76521c5d95994394b327fc483d258227"},{"index":1,"title":"K063--Crescent House EST4 Fire Alarm Upgrade Bedford VA Medical Center","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-20T11:30:43.067Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"76521c5d95994394b327fc483d258227","solicitation_number":"36C24126Q0434"}],"contacts":[{"name":"Yolanda Rankin","role":"primary","email":"Yolanda.Rankin@va.gov","phone":"978-890-2709","title":"Contract Specialist"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"caea56e47f264519be3bca492955d4b7","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"lineage_id":"76521c5d95994394b327fc483d258227","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-05T12:23:27.122633447Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"2df33b716cf37ed5a4baae6aae40d389e4b187fa2aa6748bda3b8d550ceee8a0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-05T12:23:27.122633447Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Purpose of Amendment\nThe purpose of this amendment is to provide responses to questions submitted regarding the solicitation. As a result of these questions and responses, the response due date will be extended to May 6, 2026.\nQuestion: Are manufacturer-supported, UL-listed fire alarm control panels compatible with the existing devices acceptable as an alternative to the specified EST4 fire alarm control panel?\nAnswer: No. Compatible alternative panels will not be accepted. An Edwards EST4 fire alarm control panel is specifically required for this upgrade.\nQuestion: If troubleshooting the \"unforeseen\" issues or the known MAP fault exceeds the 10 hours allocated in CLIN 0003, will the government issue a contract modification, or is the contractor expected to absorb the cost of indefinite repairs under the strict Firm-Fixed Price terms? \nAnswer: No, the contractor is not expected to absorb the cost of indefinite repairs. The unit is a single floor that occupies approximately 1100-1200sqft. It is 5 rooms with 2 bedrooms and drop ceilings throughout, that is located one apartment away from the main panel. Unit 110 has 5 peripheral devices in it: 1 addressable and 2 non-addressable listed smoke detectors, 1 horn/strobe, and 1 pull station. The replacement of all peripherals in the apartment is already included elsewhere in the contract and that cost will be accounted for under that portion. 10 man hours is reasonable to do any remaining troubleshooting/repairs to correct any remaining wiring or programming problem(s). \nQuestion: Can the government provide the historical maintenance logs or the specific trouble codes currently displayed on the EST3 panel regarding the \"known MAP fault\" so contractors can accurately assess the severity of the issue?\nAnswer: The system is annually tested, and all devices have reported to have passed all required tests. \nSomething was bypassed; I was told it was in apartment 110. I was told there was an issue there. I was not told what the issue was and/or it could not be made clear what the issue was.\nThe last alerts on the panel are:\n0001 Local Trbl Act Cresent House Building\n0002 Disabled Active 01020687 Ground Fault Data Card 2\n0003 Local Trbl Act 01020682 Map Fault Data Card 2\n\nQuestion: Can you confirm if the new EST4 panel will require specific legacy loop controller cards or modules to communicate effectively with the 77 existing non-addressable smoke detectors? \nAnswer: The non-addressable smoke detectors are not tied into the fire alarm panel. They are independent and function to alert residents of cooking issues prior to creating a fire and setting off the addressable smoke detectors that are tied into the panel. \nQuestion: If existing field wiring is found to have ground faults or degradation that prevents proper I/O point-to-point testing with the highly sensitive new EST4 panel, will the government provide a contract modification to correct these issues?\nAnswer: No, depending on the location and scope of the problem outside of the 10 hrs already allotted, there would either be another contract solicitation to replace all the wiring, or the wiring would be replaced on site by local personnel.\nQuestion: Can the government provide the exact make, model, K-factor, and temperature rating of the \"primary style\" sprinkler heads currently installed?\nAnswer: (See Pic)\nViking VK302, Model M, 5.6K, Standard Pendent, QR, Â½ NPT, Chrome, 155deg F, equivalent or better.\n\nQuestion: Can the government confirm the specific candela rating of the existing horn-strobes in Apartment 110, and verify that replacing them with \"identical units\" will still meet current NFPA 72 spacing and visual notification requirements for a multi-bedroom unit?\nAnswer: Yes,  identical units  or better if desired will meet the requirements. \n\nQuestion: Section B of the scope of work states shop drawings are to be approved by the VA and AHJ. Can you clarify who the AHJ is in this case? In our experience, the VA is the AHJ, so we re just looking for clarity regarding who else needs to approve the shop drawings.\nAnswer: The Authority Having Jurisdiction will be part of VA s internal approval process. \nQuestion: Section G of the scope of work requires a minimum one-year warranty on all equipment and installation labor to include all reused/reinstalled equipment components. Can you clarify what the warranty is intended to cover with respect to reused equipment? Are you expecting existing smoke detectors, or other similar equipment which we do not touch as part of this upgrade, to be covered under the warranty? Upgrading this fire alarm panel wouldn t typically warrant the entire fire alarm system, especially those components which are existing to remain.\nAnswer: The contractor is not expected to warrant the entire system with all peripheral devices for 1 year. Only the things that the contractor replaces, installs, or reuses. \nExample: If the contractor decides to reuse one of the modules from the old panel, then they just need to warrant that module for a year for replacement including parts and labor at no additional cost to the government. \nQuestion: Section G of the scope of work also requires post-installation technical support by contract terms. What are these terms and how long is this support intended to last? Outside of the warranty, any additional support would need to be handled via contract modification or a NTE line item for a fixed number of support hours. Offerors cannot provide fair and reasonable pricing by including an unknown amount of additional undefined support.\nAnswer: After the new system is completely installed, tested, and there are no issues, there should be up to a 1-hour exit brief to answer any questions and provide answers to the staff if they have any questions. This would also be a good time to hand-over any paperwork, manuals, testing certificates, etc \nQuestion: Is this system a Speaker Strobe System or Horn Strobe System? The RFP says \"Horns Strobes with Speakers\"\nAnswer: Horn Strobe.\n\n\nQuestion: If speaker strobe system, are we installing a Microphone in the Main Panel and/or the Annunciator?\nAnswer: Microphone is not necessary.\nQuestion: Can we get a copy of the existing Edwards SDU program from the original installer? This would answer most questions about system architecture and will be needed for the conversion from EST3 to EST4\nAnswer: We have a copy of the original installation on a flash drive at the panel. This would be made available at the time of the upgrade. The VA does not allow us the capability to transfer that information from the USB onto a government computer to send out. I will attach a modified printout copy of Q1/FY26 Fire/Life Safety System Inspection, Testing and/or Maintenance Certificate. This lists all the devices. \nQuestion: Are there local 120v Devices in the apartments (maybe these are the non-addressable detectors) or do they need sounder bases with the smoke detectors for general alarm? \nAnswer: The local 120v devices listed are not tied into the panel system. (Deeper explanation under response for question 4)\nQuestion: Are manufacturer-supported, UL-listed fire alarm control panels compatible with the existing devices acceptable as an alternative to the specified EST4 fire alarm control panel if there s a cost savings available for the government?\nAnswer: No, the facility wants uniformity among the multiple buildings at multiple sites. This affords the government a separate cost savings not included in this upgrade.","text":"Purpose of Amendment\nThe purpose of this amendment is to provide responses to questions submitted regarding the solicitation. As a result of these questions and responses, the response due date will be extended to May 6, 2026.\nQuestion: Are manufacturer-supported, UL-listed fire alarm control panels compatible with the existing devices acceptable as an alternative to the specified EST4 fire alarm control panel?\nAnswer: No. Compatible alternative panels will not be accepted. An Edwards EST4 fire alarm control panel is specifically required for this upgrade.\nQuestion: If troubleshooting the \"unforeseen\" issues or the known MAP fault exceeds the 10 hours allocated in CLIN 0003, will the government issue a contract modification, or is the contractor expected to absorb the cost of indefinite repairs under the strict Firm-Fixed Price terms?\nAnswer: No, the contractor is not expected to absorb the cost of indefinite repairs. The unit is a single floor that occupies approximately 1100-1200sqft. It is 5 rooms with 2 bedrooms and drop ceilings throughout, that is located one apartment away from the main panel. Unit 110 has 5 peripheral devices in it: 1 addressable and 2 non-addressable listed smoke detectors, 1 horn/strobe, and 1 pull station. The replacement of all peripherals in the apartment is already included elsewhere in the contract and that cost will be accounted for under that portion. 10 man hours is reasonable to do any remaining troubleshooting/repairs to correct any remaining wiring or programming problem(s).\nQuestion: Can the government provide the historical maintenance logs or the specific trouble codes currently displayed on the EST3 panel regarding the \"known MAP fault\" so contractors can accurately assess the severity of the issue?\nAnswer: The system is annually tested, and all devices have reported to have passed all required tests.\nSomething was bypassed; I was told it was in apartment 110. I was told there was an issue there. I was not told what the issue was and/or it could not be made clear what the issue was.\nThe last alerts on the panel are:\n0001 Local Trbl Act Cresent House Building\n0002 Disabled Active 01020687 Ground Fault Data Card 2\n0003 Local Trbl Act 01020682 Map Fault Data Card 2\n\nQuestion: Can you confirm if the new EST4 panel will require specific legacy loop controller cards or modules to communicate effectively with the 77 existing non-addressable smoke detectors?\nAnswer: The non-addressable smoke detectors are not tied into the fire alarm panel. They are independent and function to alert residents of cooking issues prior to creating a fire and setting off the addressable smoke detectors that are tied into the panel.\nQuestion: If existing field wiring is found to have ground faults or degradation that prevents proper I/O point-to-point testing with the highly sensitive new EST4 panel, will the government provide a contract modification to correct these issues?\nAnswer: No, depending on the location and scope of the problem outside of the 10 hrs already allotted, there would either be another contract solicitation to replace all the wiring, or the wiring would be replaced on site by local personnel.\nQuestion: Can the government provide the exact make, model, K-factor, and temperature rating of the \"primary style\" sprinkler heads currently installed?\nAnswer: (See Pic)\nViking VK302, Model M, 5.6K, Standard Pendent, QR, Â½ NPT, Chrome, 155deg F, equivalent or better.\n\nQuestion: Can the government confirm the specific candela rating of the existing horn-strobes in Apartment 110, and verify that replacing them with \"identical units\" will still meet current NFPA 72 spacing and visual notification requirements for a multi-bedroom unit?\nAnswer: Yes, identical units or better if desired will meet the requirements.\n\nQuestion: Section B of the scope of work states shop drawings are to be approved by the VA and AHJ. Can you clarify who the AHJ is in this case? In our experience, the VA is the AHJ, so we re just looking for clarity regarding who else needs to approve the shop drawings.\nAnswer: The Authority Having Jurisdiction will be part of VA s internal approval process.\nQuestion: Section G of the scope of work requires a minimum one-year warranty on all equipment and installation labor to include all reused/reinstalled equipment components. Can you clarify what the warranty is intended to cover with respect to reused equipment? Are you expecting existing smoke detectors, or other similar equipment which we do not touch as part of this upgrade, to be covered under the warranty? Upgrading this fire alarm panel wouldn t typically warrant the entire fire alarm system, especially those components which are existing to remain.\nAnswer: The contractor is not expected to warrant the entire system with all peripheral devices for 1 year. Only the things that the contractor replaces, installs, or reuses.\nExample: If the contractor decides to reuse one of the modules from the old panel, then they just need to warrant that module for a year for replacement including parts and labor at no additional cost to the government.\nQuestion: Section G of the scope of work also requires post-installation technical support by contract terms. What are these terms and how long is this support intended to last? Outside of the warranty, any additional support would need to be handled via contract modification or a NTE line item for a fixed number of support hours. Offerors cannot provide fair and reasonable pricing by including an unknown amount of additional undefined support.\nAnswer: After the new system is completely installed, tested, and there are no issues, there should be up to a 1-hour exit brief to answer any questions and provide answers to the staff if they have any questions. This would also be a good time to hand-over any paperwork, manuals, testing certificates, etc\nQuestion: Is this system a Speaker Strobe System or Horn Strobe System? The RFP says \"Horns Strobes with Speakers\"\nAnswer: Horn Strobe.\n\nQuestion: If speaker strobe system, are we installing a Microphone in the Main Panel and/or the Annunciator?\nAnswer: Microphone is not necessary.\nQuestion: Can we get a copy of the existing Edwards SDU program from the original installer? This would answer most questions about system architecture and will be needed for the conversion from EST3 to EST4\nAnswer: We have a copy of the original installation on a flash drive at the panel. This would be made available at the time of the upgrade. The VA does not allow us the capability to transfer that information from the USB onto a government computer to send out. I will attach a modified printout copy of Q1/FY26 Fire/Life Safety System Inspection, Testing and/or Maintenance Certificate. This lists all the devices.\nQuestion: Are there local 120v Devices in the apartments (maybe these are the non-addressable detectors) or do they need sounder bases with the smoke detectors for general alarm?\nAnswer: The local 120v devices listed are not tied into the panel system. (Deeper explanation under response for question 4)\nQuestion: Are manufacturer-supported, UL-listed fire alarm control panels compatible with the existing devices acceptable as an alternative to the specified EST4 fire alarm control panel if there s a cost savings available for the government?\nAnswer: No, the facility wants uniformity among the multiple buildings at multiple sites. This affords the government a separate cost savings not included in this upgrade.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"36C24126Q0434","place_of_performance":{"street":"Crescent House Transitional Residence Program 15 Veterans Way","street2":"Lowell, MA 01852"},"product_service_code":"K063"}],"due_at":"2026-05-06T16:00:00Z","due_date":"2026-05-06","closes_at":"2026-05-06T16:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","state":"MA","county":"25017","county_name":"Middlesex County","city":"2501704615","city_name":"Bedford","country":null,"state_source":null,"state_evidence":null,"site_key":"bedford-va-medical-center-ma","winner_key":"ZVRCBGMEGNX5","amount":null,"linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-10-05T13:12:22.352488Z","principal_notice_id":"caea56e47f264519be3bca492955d4b7","description":{"text":"Purpose of Amendment\nThe purpose of this amendment is to provide responses to questions submitted regarding the solicitation. As a result of these questions and responses, the response due date will be extended to May 6, 2026.\nQuestion: Are manufacturer-supported, UL-listed fire alarm control panels compatible with the existing devices acceptable as an alternative to the specified EST4 fire alarm control panel?\nAnswer: No. Compatible alternative panels will not be accepted. An Edwards EST4 fire alarm control panel is specifically required for this upgrade.\nQuestion: If troubleshooting the \"unforeseen\" issues or the known MAP fault exceeds the 10 hours allocated in CLIN 0003, will the government issue a contract modification, or is the contractor expected to absorb the cost of indefinite repairs under the strict Firm-Fixed Price terms?\nAnswer: No, the contractor is not expected to absorb the cost of indefinite repairs. The unit is a single floor that occupies approximately 1100-1200sqft. It is 5 rooms with 2 bedrooms and drop ceilings throughout, that is located one apartment away from the main panel. Unit 110 has 5 peripheral devices in it: 1 addressable and 2 non-addressable listed smoke detectors, 1 horn/strobe, and 1 pull station. The replacement of all peripherals in the apartment is already included elsewhere in the contract and that cost will be accounted for under that portion. 10 man hours is reasonable to do any remaining troubleshooting/repairs to correct any remaining wiring or programming problem(s).\nQuestion: Can the government provide the historical maintenance logs or the specific trouble codes currently displayed on the EST3 panel regarding the \"known MAP fault\" so contractors can accurately assess the severity of the issue?\nAnswer: The system is annually tested, and all devices have reported to have passed all required tests.\nSomething was bypassed; I was told it was in apartment 110. I was told there was an issue there. I was not told what the issue was and/or it could not be made clear what the issue was.\nThe last alerts on the panel are:\n0001 Local Trbl Act Cresent House Building\n0002 Disabled Active 01020687 Ground Fault Data Card 2\n0003 Local Trbl Act 01020682 Map Fault Data Card 2\n\nQuestion: Can you confirm if the new EST4 panel will require specific legacy loop controller cards or modules to communicate effectively with the 77 existing non-addressable smoke detectors?\nAnswer: The non-addressable smoke detectors are not tied into the fire alarm panel. They are independent and function to alert residents of cooking issues prior to creating a fire and setting off the addressable smoke detectors that are tied into the panel.\nQuestion: If existing field wiring is found to have ground faults or degradation that prevents proper I/O point-to-point testing with the highly sensitive new EST4 panel, will the government provide a contract modification to correct these issues?\nAnswer: No, depending on the location and scope of the problem outside of the 10 hrs already allotted, there would either be another contract solicitation to replace all the wiring, or the wiring would be replaced on site by local personnel.\nQuestion: Can the government provide the exact make, model, K-factor, and temperature rating of the \"primary style\" sprinkler heads currently installed?\nAnswer: (See Pic)\nViking VK302, Model M, 5.6K, Standard Pendent, QR, Â½ NPT, Chrome, 155deg F, equivalent or better.\n\nQuestion: Can the government confirm the specific candela rating of the existing horn-strobes in Apartment 110, and verify that replacing them with \"identical units\" will still meet current NFPA 72 spacing and visual notification requirements for a multi-bedroom unit?\nAnswer: Yes, identical units or better if desired will meet the requirements.\n\nQuestion: Section B of the scope of work states shop drawings are to be approved by the VA and AHJ. Can you clarify who the AHJ is in this case? In our experience, the VA is the AHJ, so we re just looking for clarity regarding who else needs to approve the shop drawings.\nAnswer: The Authority Having Jurisdiction will be part of VA s internal approval process.\nQuestion: Section G of the scope of work requires a minimum one-year warranty on all equipment and installation labor to include all reused/reinstalled equipment components. Can you clarify what the warranty is intended to cover with respect to reused equipment? Are you expecting existing smoke detectors, or other similar equipment which we do not touch as part of this upgrade, to be covered under the warranty? Upgrading this fire alarm panel wouldn t typically warrant the entire fire alarm system, especially those components which are existing to remain.\nAnswer: The contractor is not expected to warrant the entire system with all peripheral devices for 1 year. Only the things that the contractor replaces, installs, or reuses.\nExample: If the contractor decides to reuse one of the modules from the old panel, then they just need to warrant that module for a year for replacement including parts and labor at no additional cost to the government.\nQuestion: Section G of the scope of work also requires post-installation technical support by contract terms. What are these terms and how long is this support intended to last? Outside of the warranty, any additional support would need to be handled via contract modification or a NTE line item for a fixed number of support hours. Offerors cannot provide fair and reasonable pricing by including an unknown amount of additional undefined support.\nAnswer: After the new system is completely installed, tested, and there are no issues, there should be up to a 1-hour exit brief to answer any questions and provide answers to the staff if they have any questions. This would also be a good time to hand-over any paperwork, manuals, testing certificates, etc\nQuestion: Is this system a Speaker Strobe System or Horn Strobe System? The RFP says \"Horns Strobes with Speakers\"\nAnswer: Horn Strobe.\n\nQuestion: If speaker strobe system, are we installing a Microphone in the Main Panel and/or the Annunciator?\nAnswer: Microphone is not necessary.\nQuestion: Can we get a copy of the existing Edwards SDU program from the original installer? This would answer most questions about system architecture and will be needed for the conversion from EST3 to EST4\nAnswer: We have a copy of the original installation on a flash drive at the panel. This would be made available at the time of the upgrade. The VA does not allow us the capability to transfer that information from the USB onto a government computer to send out. I will attach a modified printout copy of Q1/FY26 Fire/Life Safety System Inspection, Testing and/or Maintenance Certificate. This lists all the devices.\nQuestion: Are there local 120v Devices in the apartments (maybe these are the non-addressable detectors) or do they need sounder bases with the smoke detectors for general alarm?\nAnswer: The local 120v devices listed are not tied into the panel system. (Deeper explanation under response for question 4)\nQuestion: Are manufacturer-supported, UL-listed fire alarm control panels compatible with the existing devices acceptable as an alternative to the specified EST4 fire alarm control panel if there s a cost savings available for the government?\nAnswer: No, the facility wants uniformity among the multiple buildings at multiple sites. This affords the government a separate cost savings not included in this upgrade.","html":"Purpose of Amendment\nThe purpose of this amendment is to provide responses to questions submitted regarding the solicitation. As a result of these questions and responses, the response due date will be extended to May 6, 2026.\nQuestion: Are manufacturer-supported, UL-listed fire alarm control panels compatible with the existing devices acceptable as an alternative to the specified EST4 fire alarm control panel?\nAnswer: No. Compatible alternative panels will not be accepted. An Edwards EST4 fire alarm control panel is specifically required for this upgrade.\nQuestion: If troubleshooting the \"unforeseen\" issues or the known MAP fault exceeds the 10 hours allocated in CLIN 0003, will the government issue a contract modification, or is the contractor expected to absorb the cost of indefinite repairs under the strict Firm-Fixed Price terms? \nAnswer: No, the contractor is not expected to absorb the cost of indefinite repairs. The unit is a single floor that occupies approximately 1100-1200sqft. It is 5 rooms with 2 bedrooms and drop ceilings throughout, that is located one apartment away from the main panel. Unit 110 has 5 peripheral devices in it: 1 addressable and 2 non-addressable listed smoke detectors, 1 horn/strobe, and 1 pull station. The replacement of all peripherals in the apartment is already included elsewhere in the contract and that cost will be accounted for under that portion. 10 man hours is reasonable to do any remaining troubleshooting/repairs to correct any remaining wiring or programming problem(s). \nQuestion: Can the government provide the historical maintenance logs or the specific trouble codes currently displayed on the EST3 panel regarding the \"known MAP fault\" so contractors can accurately assess the severity of the issue?\nAnswer: The system is annually tested, and all devices have reported to have passed all required tests. \nSomething was bypassed; I was told it was in apartment 110. I was told there was an issue there. I was not told what the issue was and/or it could not be made clear what the issue was.\nThe last alerts on the panel are:\n0001 Local Trbl Act Cresent House Building\n0002 Disabled Active 01020687 Ground Fault Data Card 2\n0003 Local Trbl Act 01020682 Map Fault Data Card 2\n\nQuestion: Can you confirm if the new EST4 panel will require specific legacy loop controller cards or modules to communicate effectively with the 77 existing non-addressable smoke detectors? \nAnswer: The non-addressable smoke detectors are not tied into the fire alarm panel. They are independent and function to alert residents of cooking issues prior to creating a fire and setting off the addressable smoke detectors that are tied into the panel. \nQuestion: If existing field wiring is found to have ground faults or degradation that prevents proper I/O point-to-point testing with the highly sensitive new EST4 panel, will the government provide a contract modification to correct these issues?\nAnswer: No, depending on the location and scope of the problem outside of the 10 hrs already allotted, there would either be another contract solicitation to replace all the wiring, or the wiring would be replaced on site by local personnel.\nQuestion: Can the government provide the exact make, model, K-factor, and temperature rating of the \"primary style\" sprinkler heads currently installed?\nAnswer: (See Pic)\nViking VK302, Model M, 5.6K, Standard Pendent, QR, Â½ NPT, Chrome, 155deg F, equivalent or better.\n\nQuestion: Can the government confirm the specific candela rating of the existing horn-strobes in Apartment 110, and verify that replacing them with \"identical units\" will still meet current NFPA 72 spacing and visual notification requirements for a multi-bedroom unit?\nAnswer: Yes,  identical units  or better if desired will meet the requirements. \n\nQuestion: Section B of the scope of work states shop drawings are to be approved by the VA and AHJ. Can you clarify who the AHJ is in this case? In our experience, the VA is the AHJ, so we re just looking for clarity regarding who else needs to approve the shop drawings.\nAnswer: The Authority Having Jurisdiction will be part of VA s internal approval process. \nQuestion: Section G of the scope of work requires a minimum one-year warranty on all equipment and installation labor to include all reused/reinstalled equipment components. Can you clarify what the warranty is intended to cover with respect to reused equipment? Are you expecting existing smoke detectors, or other similar equipment which we do not touch as part of this upgrade, to be covered under the warranty? Upgrading this fire alarm panel wouldn t typically warrant the entire fire alarm system, especially those components which are existing to remain.\nAnswer: The contractor is not expected to warrant the entire system with all peripheral devices for 1 year. Only the things that the contractor replaces, installs, or reuses. \nExample: If the contractor decides to reuse one of the modules from the old panel, then they just need to warrant that module for a year for replacement including parts and labor at no additional cost to the government. \nQuestion: Section G of the scope of work also requires post-installation technical support by contract terms. What are these terms and how long is this support intended to last? Outside of the warranty, any additional support would need to be handled via contract modification or a NTE line item for a fixed number of support hours. Offerors cannot provide fair and reasonable pricing by including an unknown amount of additional undefined support.\nAnswer: After the new system is completely installed, tested, and there are no issues, there should be up to a 1-hour exit brief to answer any questions and provide answers to the staff if they have any questions. This would also be a good time to hand-over any paperwork, manuals, testing certificates, etc \nQuestion: Is this system a Speaker Strobe System or Horn Strobe System? The RFP says \"Horns Strobes with Speakers\"\nAnswer: Horn Strobe.\n\n\nQuestion: If speaker strobe system, are we installing a Microphone in the Main Panel and/or the Annunciator?\nAnswer: Microphone is not necessary.\nQuestion: Can we get a copy of the existing Edwards SDU program from the original installer? This would answer most questions about system architecture and will be needed for the conversion from EST3 to EST4\nAnswer: We have a copy of the original installation on a flash drive at the panel. This would be made available at the time of the upgrade. The VA does not allow us the capability to transfer that information from the USB onto a government computer to send out. I will attach a modified printout copy of Q1/FY26 Fire/Life Safety System Inspection, Testing and/or Maintenance Certificate. This lists all the devices. \nQuestion: Are there local 120v Devices in the apartments (maybe these are the non-addressable detectors) or do they need sounder bases with the smoke detectors for general alarm? \nAnswer: The local 120v devices listed are not tied into the panel system. (Deeper explanation under response for question 4)\nQuestion: Are manufacturer-supported, UL-listed fire alarm control panels compatible with the existing devices acceptable as an alternative to the specified EST4 fire alarm control panel if there s a cost savings available for the government?\nAnswer: No, the facility wants uniformity among the multiple buildings at multiple sites. This affords the government a separate cost savings not included in this upgrade.","origin":"detail"},"contacts":[{"name":"Yolanda Rankin","role":"primary","email":"Yolanda.Rankin@va.gov","phone":"978-890-2709","title":"Contract Specialist"}],"place_of_performance":{"street":"Crescent House Transitional Residence Program 15 Veterans Way","street2":"Lowell, MA 01852"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"naics_codes":["561621"],"award":{"awardee":{}},"attachments":[{"resource_id":"f4d3a9a5475e4085b3d4f47de04387b3","name":"36C24126Q0434.docx","kind":"file","mime_type":".docx","size_bytes":1000694,"posted_at":"2026-04-20T11:30:43.067Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f4d3a9a5475e4085b3d4f47de04387b3/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24126P0428_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24126P0428_3600_-NONE-_-NONE-/","piid":"36C24126P0428","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"ZVRCBGMEGNX5","recipient_name":"BOISSONNEAULT ELECTRIC CORP","recipient_uei":"ZVRCBGMEGNX5","recipient_cage":"81U16","recipient_city":"DRACUT","recipient_state":"MA","sub_name":"Department of Veterans Affairs","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","office_key":"o-36C241","first_action_date":"2026-05-28","last_action_date":"2026-10-21","actions":2,"obligated":"42500.00","current_total_value":"42500.00","potential_total_value":"42500.00","naics":"561621","psc":"K063","extent_competed":"COMPETED UNDER SAP","set_aside":"SERVICE DISABLED VETERAN OWNED SMALL BUSINESS SET-ASIDE","offers_received":4,"description":"CRESENT HOUSE FIRE ALARM SYSTEM","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24126Q0434 equals the FPDS solicitation identifier","same awarding office 36C241"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24127Q0084","latest_notice_id":"939b8f3021be4a75ae5972b0c7ffb9ae","title":"X1EA--CWM VA Police Use of shooting range.","solicitation_number":"36C24127Q0084","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"611699","psc":"X1EA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24127Q0017","latest_notice_id":"d60676ea33af4051b90a1953ab55743e","title":"S201--36C24127Q0017 Windows Washing Service Amendment 0002","solicitation_number":"36C24127Q0017","notice_type":"k","first_type":"k","first_posted":"2026-10-26","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"561720","psc":"S201","set_aside":"SDVOSBC","state":"MA","county":"25017","county_name":"Middlesex County","city":"2501704615","city_name":"Bedford","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24127Q0044","latest_notice_id":"a2f2fe28c1ec4687b2a2955cf947935e","title":"9140--Togus Fuel Oil and Diesel Delivery","solicitation_number":"36C24127Q0044","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"324110","psc":"9140","set_aside":"SBA","state":"ME","county":"23011","county_name":"Kennebec County","city":"2302100","city_name":"Augusta","country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"04330","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24127Q0076","latest_notice_id":"bb30bc78067840a082b5d9e12eceddd2","title":"Q601--Sources sought Boston Medical Coding Period of Period 01/01/2027-04/01/2027","solicitation_number":"36C24127Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541219","psc":"Q601","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24127Q0030","latest_notice_id":"10c3d2d3d0c543179707f8cc9448f701","title":"J061--Eaton Powerware System Replacement","solicitation_number":"36C24127Q0030","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J061","set_aside":"SDVOSBC","state":"NH","county":"33011","county_name":"Hillsborough County","city":"3345140","city_name":"Manchester","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"140PP027Q0038","latest_notice_id":"c32706021d30409b8ec04ebf6c0a68dc","title":"12043-FRLA-ALARM MONITORING CONTRACT","solicitation_number":"140PP027Q0038","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-18T15:00:00Z","due_date":"2026-12-18","closes_at":"2026-12-18T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"561621","psc":"S211","set_aside":"SBA","state":"MA","county":"25021","county_name":"Norfolk County","city":"2509210","city_name":"Brookline","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"IHSSS11182026","latest_notice_id":"38800d0d6ad64cecabc18acf586542a5","title":"Fire Monitoring, Inspections, Maintenance, and Remediation Services","solicitation_number":"IHSSS11182026","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T22:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7527","sub_name":"INDIAN HEALTH SERVICE","office_key":"o-75H721","office_name":"LAWTON INDIAN HOSPITAL","naics":"561621","psc":"6350","set_aside":"ISBEE","state":"OK","county":"40109","county_name":"Oklahoma County","city":"4055000","city_name":"Oklahoma City","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"3030127RFQ000001","latest_notice_id":"140cd38f6403477ebe7b5d43a5d18e61","title":"USCG Station Wachapreague Alarm Monitoring Service","solicitation_number":"3030127RFQ000001","notice_type":"o","first_type":"o","first_posted":"2026-11-12","last_posted":"2026-11-18","notices":2,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70ZL30","office_name":"BASE PORTSMOUTH","naics":"561621","psc":"S211","set_aside":"SBA","state":"VA","county":"51001","county_name":"Accomack County","city":"5182320","city_name":"Wachapreague","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-24T06:18:02.791414Z"}],"similar_open_total":27,"indexable":false}