{"canonical":"https://sealedbidder.com/opportunities/36c24126q0098","key":"36C24126Q0098","url":"https://sealedbidder.com/opportunities/36c24126q0098","title":"J041--Chiller System Maintenance","solicitation_number":"36C24126Q0098","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-11-25T17:00:00Z","first_posted":"2025-11-20","last_posted":"2025-11-20","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J041","set_aside":null,"place_state":"MA","place_scope":"site","site":null,"place_state_source":"description","place_evidence":"EDICAL CENTER, 940 BELMONT STREET, BROCKTON MA 02301","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"7d31dd3e974d45a5bb438c19657434e2","title":"J041--Chiller System Maintenance","solicitation_number":"36C24126Q0098","notice_type":"s","base_type":"s","posted":"2025-11-20","posted_at":"2025-11-20T18:31:59.929Z","due_at":"2025-11-25T17:00:00Z","due_date":"2025-11-25","cancelled":false,"archived":true,"archive_date":"2026-01-24","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7d31dd3e974d45a5bb438c19657434e2/view","enriched":true,"history":[{"index":3,"title":"J041--Chiller System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-20T18:31:59.929Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"7d31dd3e974d45a5bb438c19657434e2","solicitation_number":"36C24126Q0098"}]}],"latest_notice_id":"7d31dd3e974d45a5bb438c19657434e2","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-11-20","posted_at":"2025-11-20T18:31:59.929Z","created_at":"2025-11-20T18:31:57.629Z","modified_at":"2026-01-25T05:00:07.598Z","response_deadline":{"raw":"2025-11-25T12:00:00-05:00","utc":"2025-11-25T17:00:00Z","date":"2025-11-25","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7d31dd3e974d45a5bb438c19657434e2/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J041--Chiller System Maintenance","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-01-24","archive_type":"auto_custom"},"history":[{"index":3,"title":"J041--Chiller System Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-20T18:31:59.929Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"7d31dd3e974d45a5bb438c19657434e2","solicitation_number":"36C24126Q0098"}],"contacts":[{"name":"Issa Shawki","role":"primary","email":"issa.shawki@va.gov","phone":"774-826-3192","title":"Contracting Officer"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"7d31dd3e974d45a5bb438c19657434e2","lineage_id":"7d31dd3e974d45a5bb438c19657434e2","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-22T00:35:24.722229115Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"3a305646a2eb00efcada53243a3c7efe347a1e7422d9a5188ebfe30bfe364b9c","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-22T00:35:24.722229115Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with TRANE U.S. Inc., for the following requirement:\n\nSTATEMENT OF WORK\nChiller Maintenance\nEQUIPMENT\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Chiller\n1\nTrane\nCGAM030B2G\nU12F30551\nEYE CLINIC\nAir-Cooled Chiller\n1\nTrane\nCGAM060A2P\nU16D54225\nBLDG 3, CH 1\nAir-Cooled Chiller\n1\nTrane\nCGAM080F2H\nU12K32472\nSPD ADDITION\nAir-Cooled Chiller\n1\nTrane\nCGAM080F2H\nU12K32473\nSPD ADDITION\nAir-Cooled Chiller\n1\nTrane\nCGAM130F2A\nU24E02145\nBUILDING 5 CH-1\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UR\nU08M02830\nBLDG 2, CH 1\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UK\nU05F02407\nBLDG 7, CH 3\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004U1\nU19E03810\nCH-2\n\nSCOPE OF WORK\nThe Contractor shall provide all supervision, personnel, material, parts, equipment, supplies, labor, and transportation in performing basic preventive maintenance on the chiller systems and equipment listed in this Statement of Work located at the Department of Veterans Affairs Medical Center, 940 Belmont Street, Brockton MA 02301 in accordance with all terms and conditions of this task order and accepted quotation.\nPeriod of Performance: This will be a firm-fixed-price, base year plus four option years task order.\n\n\n\nThe following is the scope of services to be performed on Covered Equipment. Items marked with an  X  are included in this contract.\n\n\n\nServices Included\nCooling Seasonal Service\nX\nSeasonal Start-up\nX\nOperating Inspections Qty\nX\nSystem Shutdown\nX\nAnnual Coil Cleaning Seasonal Maintenance\n\n\nServices Included\nLabor and Materials for Covered Equipment\nX\nScheduled Maintenance Labor\nX\nScheduled Maintenance Parts and Materials\n\nServices Included\nPredictive Testing and Analysis for Covered Equipment Chiller(s) Only\nX\nSpectrographic Oil Analysis.\nX\nRefrigerant Analysis   Provides early warning of internal failure.\nX\nKestrelView  Analysis   Requires Trane laptop and Trane software\nX\nOil Removal and Disposal by Trane by EPA Guidelines\n\nServices Included\nAdditional Services\nX\nAir Cooled Condenser Coil Cleaning once per year\n\nVA Brockton Hospital Equipment\n\nThe following \"Covered Equipment\" will be serviced at VA Hospital Brockton:\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UK\nU05F02407\nBLDG 7, CH 3\n\nService Description\nQuantity Per Term\nOil Sample/Spectrographic Analysis for RTAC (Service 1)\n1\nRTAC (7310) Annual Maintenance (Service 8)\n1\nRTAC Seasonal Start-Up (Service 10)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Quarterly Inspection (Service 15)\n4\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UR\nU08M02830\nBLDG 2, CH 1\n\nService Description\nQuantity Per Term\nOil Sample/Spectrographic Analysis for RTAC (Service 1)\n1\nRTAC (7310) Annual Maintenance (Service 9)\n1\nRTAC Seasonal Start-Up (Service 10)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Quarterly Inspection (Service 15)\n4\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM030B2G\nU12F30551\nEYE CLINIC\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM060A2P\nU16D54225\nBLDG 3, CH 1\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM080F2H\nU12K32472\nSPD ADDITION\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM080F2H\nU12K32473\nSPD ADDITION\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM130F2A\nU24E02145\nBUILDING 5 CH-1\n\nService Description\nQuantity Per Term\nCGAM Oil sample/analysis (Service 2)\n1\nAir Cooled Scroll Seasonal Start Up (Service 3)\n1\nCGAM Coil Cleaning (Service 4)\n1\nCGAM Quarterly Inspection (Service 5)\n4\nAir Cooled Scroll Seasonal Shut Down (Service 6)\n1\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM) - Brazil\n1\nTrane\nRTAC2004U1\nU19E03810\nCH-2\n\nService Description\nQuantity Per Term\nR MACHINE REF SAMPLE (Service 7)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Seasonal Start Up (Service 13)\n1\nRTAC Annual (Solution Coil Cleaning) (Service 14)\n1\nRTAC Quarterly Inspection (Service 16)\n4\n\nSERVICE FLOW DETAILS\nService 1: Oil Sample/Spectrographic Analysis for RTAC\nDescription\nPull oil sample for spectrographic analysis.\nService 2: CGAM Oil sample/analysis\nDescription\nPull oil sample for spectrographic analysis.\nService 3: Air Cooled Scroll Seasonal Start Up\nDescription\nCustomer Notification\nInitial Site Safety Inspection\nLock Out Tag Out (Standard)\nElectrical Inspection - Control Panel\nInspect Strainer and Pump - BPHE Seasonal Startup\nRemove LOTO and Check Heater Operation\nCompressor Oil Level Pre-Start\nTechView/KestrelView Connection\nPre-Start Chiller Check CGAM\nSeasonal Start Unit-CGAM\nCompressor Oil Level Check\nService 4: CGAM Coil Cleaning\nDescription\nCustomer Notification\nInitial Site Safety Inspection\nLock Out Tag Out (Standard)\nCoil Cleaning Solution\nRemove Lock Out Tag Out\nReturn Unit to Normal Operation\n\nService 5: CGAM Quarterly Inspection\nDescription\nCustomer Notification of Unit Maintenance\nVisual Condenser Coil Check\nShut Down Unit\nCompressor Oil Level Check- Air-Cooled Scroll\nReturn Unit to Normal Operation\nTechView/KestrelView Connection\nReview Diagnostics\nCheck Fans for Rubbing\nCheck EXV Sight Glass\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\n\nService 6: Air Cooled Scroll Seasonal Shut Down\nDescription\nInitial Site Inspection\nReview Diagnostics (Standard)\nLock Out Tag Out (Standard)\nCheck Heater Strips\n\nService 7: R MACHINE REF SAMPLE\nDescription\nR MACHINE REF SAMPLE\nPull oil sample for spectrographic analysis.\n\nService 8: RTAC (7310) Annual Maintenance\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nLock out tag out at main disconnect.\nElectrical Inspection (RTA*)\nControl Panel Calibration Check\nRemove lock out tag out at main disconnect.\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nCompressor And Oil Separator Heater Check\nFlow/Differential Mechanical Switch Check\nCompressor Check (HeliRotor Compressors)\nWater pressure drop validation.\nOil Level Check Per Compressor\nCondenser Fans Check RTA* Per Circuit\nOil Analysis Per Compressor\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nCoil Cleaning Solution\nLow Temperature Sensor Calibration\nSub-cooling check\nStart Unit\nLeak Test Inspection (Positive Pressure)\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete required paper work\nService 9: RTAC (7310) Annual Maintenance\nDescription\nCustomer Notification\nInitial Site Inspection\nTechView/KestrelView Connection\nRun Service Report From TechView\nReview Diagnostics\nLock out tag out at main disconnect.\nElectrical Inspection (RTA*)\nControl Panel Calibration Check\nRemove lock out tag out at main disconnect.\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nCompressor And Oil Separator Heater Check\nFlow/Differential Mechanical Switch Check\nCompressor Check (HeliRotor Compressors)\nWater pressure drop validation.\nOil Level Check Per Compressor\nCondenser Fans Check RTA* Per Circuit\nOil Analysis Per Compressor\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nCoil Cleaning Solution\nLow Temperature Sensor Calibration\nSub-cooling check\nStart Unit\nLeak Test Inspection (Positive Pressure)\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete required paper work\n\nService 10: RTAC Seasonal Start-Up\nDescription\nCustomer Notification\nInitial Site Inspection\nStart-Up Sequence (RTAC)\nReview Diagnostics\nLock Out Tag Out (Standard)\nCondenser Fans Check RTA* Per Circuit\nCompressor And Oil Separator Heater Check\nCheck oil levels\nCondenser Coil Check\nCompressor Check (HeliRotor Compressors)\nOil return operation check\nSub-Cooling Check\nRemove Lock Out Tag Out and Restore Power\nComplete Required Paper Work\nReview Diagnostics\nComplete Required Paper Work\nService 11: Oil Filter Replacement (Per Compressor)\nDescription\nCustomer Notification\nInitial Site Inspection\nServiceman Pump Down\nEnable Front Panel Circuit Lock Out\nTransfer After Serviceman Pump Down\nOil Filter Change-RTAC, RTAE, RTUD, RTWD\nEvacuate Compressor after Repair\nOpen Valves After Pump Down or Transfer\nRun Circuit and Check Oil Pressure Drop\nOil Level Check (Screw Machines) Per Circuit\nDisable Front Panel Circuit Lock Out\nReturn Unit to Normal Operation\n\nService 12: RTAC Seasonal Shut Down\nDescription\nInitial Site Inspection\nCustomer Notification Of Chiller Shut Down Including Lock Out\nTechView/KestrelView Connection\nReview Diagnostics\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete Required Paper Work\nService 13: RTAC Seasonal Start Up\nDescription\nCustomer Notification\nReview Diagnostics\nLock Out Tag Out (Standard)\nRemove Panels Generic\nRemove Lock Out Tag Out and Restore Power\nTechView/KestrelView Connection\nVerify Pump Operation and Water Flows-Seasonal Startup\nCompressor And Oil Separator Heater Check\nStart-Up Sequence (RTAC)\nTechview/Kestrel View Disconnection\nLock Out Tag Out (Standard)\nReinstall Panels Generic\nRemove Lock Out Tag Out and Restore Power\nComplete Required Paper Work\n\nService 14: RTAC Annual (Solution Coil Cleaning)\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nLock Out Tag Out At Main Disconnect\nElectrical Inspection (RTA*)\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nFlow/Differential Mechanical Switch Check\nRemove Lock Out Tag Out At Main Disconnect\nCondenser Fans Check RTA* Per Circuit\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nOil Level Check Per Compressor\nOil Analysis Per Compressor\nLow Temperature Sensor Calibration\nControl Panel Calibration Check\nLeak Test Inspection (Positive Pressure)\nCoil Cleaning Solution\nStart Unit\nCompressor Check (HeliRotor Compressors)\nCompressor And Oil Separator Heater Check\nTechView/KestrelView Connection\nRun Service Report From TechView\nComplete Required Paper Work\n\nService 15: RTAC Quarterly Inspection\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nCondenser Fans Check RTA* Per Circuit\nLock Out Tag Out (Standard)\nVisual Electrical Inspection\nVisual Condenser Coil Check\nRemove Lock Out Tag Out\nStart Unit\nComplete Required Paper Work\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nService 16: RTAC Quarterly Inspection\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nCondenser Fans Check RTA* Per Circuit\nLock Out Tag Out (Standard)\nVisual Electrical Inspection\nRemove Lock Out Tag Out\nStart Unit\nComplete Required Paper Work\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\n\n\nThe NAICS code for this requirement is 811310.\nTrane is the only contractor with the capability to perform the required services on the Trane controlled chillers.  The VA owned Trane Ensemble system is a proprietary control system and will only have true full compatibility with other Trane Ensemble components, software and personnel. Other contractors are unable to perform this work due to not having access to Trane software and replacement supplies.  Due to the proprietary nature of the work requiring a manufacturer and installer having qualified experience in programming Trane Ensemble and having access to Trane parts and codes/software, these proprietary issues would not allow for full and open competition.  \n\nThis notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement must clearly identify their capability to do so in writing by November 25, 2025 at 12 pm EST time. Response should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open this requirement to competition based upon responses to this notice is solely within the discretion of the Government.","text":"The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with TRANE U.S. Inc., for the following requirement:\n\nSTATEMENT OF WORK\nChiller Maintenance\nEQUIPMENT\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Chiller\n1\nTrane\nCGAM030B2G\nU12F30551\nEYE CLINIC\nAir-Cooled Chiller\n1\nTrane\nCGAM060A2P\nU16D54225\nBLDG 3, CH 1\nAir-Cooled Chiller\n1\nTrane\nCGAM080F2H\nU12K32472\nSPD ADDITION\nAir-Cooled Chiller\n1\nTrane\nCGAM080F2H\nU12K32473\nSPD ADDITION\nAir-Cooled Chiller\n1\nTrane\nCGAM130F2A\nU24E02145\nBUILDING 5 CH-1\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UR\nU08M02830\nBLDG 2, CH 1\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UK\nU05F02407\nBLDG 7, CH 3\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004U1\nU19E03810\nCH-2\n\nSCOPE OF WORK\nThe Contractor shall provide all supervision, personnel, material, parts, equipment, supplies, labor, and transportation in performing basic preventive maintenance on the chiller systems and equipment listed in this Statement of Work located at the Department of Veterans Affairs Medical Center, 940 Belmont Street, Brockton MA 02301 in accordance with all terms and conditions of this task order and accepted quotation.\nPeriod of Performance: This will be a firm-fixed-price, base year plus four option years task order.\n\nThe following is the scope of services to be performed on Covered Equipment. Items marked with an X are included in this contract.\n\nServices Included\nCooling Seasonal Service\nX\nSeasonal Start-up\nX\nOperating Inspections Qty\nX\nSystem Shutdown\nX\nAnnual Coil Cleaning Seasonal Maintenance\n\nServices Included\nLabor and Materials for Covered Equipment\nX\nScheduled Maintenance Labor\nX\nScheduled Maintenance Parts and Materials\n\nServices Included\nPredictive Testing and Analysis for Covered Equipment Chiller(s) Only\nX\nSpectrographic Oil Analysis.\nX\nRefrigerant Analysis Provides early warning of internal failure.\nX\nKestrelView Analysis Requires Trane laptop and Trane software\nX\nOil Removal and Disposal by Trane by EPA Guidelines\n\nServices Included\nAdditional Services\nX\nAir Cooled Condenser Coil Cleaning once per year\n\nVA Brockton Hospital Equipment\n\nThe following \"Covered Equipment\" will be serviced at VA Hospital Brockton:\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UK\nU05F02407\nBLDG 7, CH 3\n\nService Description\nQuantity Per Term\nOil Sample/Spectrographic Analysis for RTAC (Service 1)\n1\nRTAC (7310) Annual Maintenance (Service 8)\n1\nRTAC Seasonal Start-Up (Service 10)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Quarterly Inspection (Service 15)\n4\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UR\nU08M02830\nBLDG 2, CH 1\n\nService Description\nQuantity Per Term\nOil Sample/Spectrographic Analysis for RTAC (Service 1)\n1\nRTAC (7310) Annual Maintenance (Service 9)\n1\nRTAC Seasonal Start-Up (Service 10)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Quarterly Inspection (Service 15)\n4\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM030B2G\nU12F30551\nEYE CLINIC\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM060A2P\nU16D54225\nBLDG 3, CH 1\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM080F2H\nU12K32472\nSPD ADDITION\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM080F2H\nU12K32473\nSPD ADDITION\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM130F2A\nU24E02145\nBUILDING 5 CH-1\n\nService Description\nQuantity Per Term\nCGAM Oil sample/analysis (Service 2)\n1\nAir Cooled Scroll Seasonal Start Up (Service 3)\n1\nCGAM Coil Cleaning (Service 4)\n1\nCGAM Quarterly Inspection (Service 5)\n4\nAir Cooled Scroll Seasonal Shut Down (Service 6)\n1\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM) - Brazil\n1\nTrane\nRTAC2004U1\nU19E03810\nCH-2\n\nService Description\nQuantity Per Term\nR MACHINE REF SAMPLE (Service 7)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Seasonal Start Up (Service 13)\n1\nRTAC Annual (Solution Coil Cleaning) (Service 14)\n1\nRTAC Quarterly Inspection (Service 16)\n4\n\nSERVICE FLOW DETAILS\nService 1: Oil Sample/Spectrographic Analysis for RTAC\nDescription\nPull oil sample for spectrographic analysis.\nService 2: CGAM Oil sample/analysis\nDescription\nPull oil sample for spectrographic analysis.\nService 3: Air Cooled Scroll Seasonal Start Up\nDescription\nCustomer Notification\nInitial Site Safety Inspection\nLock Out Tag Out (Standard)\nElectrical Inspection - Control Panel\nInspect Strainer and Pump - BPHE Seasonal Startup\nRemove LOTO and Check Heater Operation\nCompressor Oil Level Pre-Start\nTechView/KestrelView Connection\nPre-Start Chiller Check CGAM\nSeasonal Start Unit-CGAM\nCompressor Oil Level Check\nService 4: CGAM Coil Cleaning\nDescription\nCustomer Notification\nInitial Site Safety Inspection\nLock Out Tag Out (Standard)\nCoil Cleaning Solution\nRemove Lock Out Tag Out\nReturn Unit to Normal Operation\n\nService 5: CGAM Quarterly Inspection\nDescription\nCustomer Notification of Unit Maintenance\nVisual Condenser Coil Check\nShut Down Unit\nCompressor Oil Level Check- Air-Cooled Scroll\nReturn Unit to Normal Operation\nTechView/KestrelView Connection\nReview Diagnostics\nCheck Fans for Rubbing\nCheck EXV Sight Glass\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\n\nService 6: Air Cooled Scroll Seasonal Shut Down\nDescription\nInitial Site Inspection\nReview Diagnostics (Standard)\nLock Out Tag Out (Standard)\nCheck Heater Strips\n\nService 7: R MACHINE REF SAMPLE\nDescription\nR MACHINE REF SAMPLE\nPull oil sample for spectrographic analysis.\n\nService 8: RTAC (7310) Annual Maintenance\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nLock out tag out at main disconnect.\nElectrical Inspection (RTA*)\nControl Panel Calibration Check\nRemove lock out tag out at main disconnect.\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nCompressor And Oil Separator Heater Check\nFlow/Differential Mechanical Switch Check\nCompressor Check (HeliRotor Compressors)\nWater pressure drop validation.\nOil Level Check Per Compressor\nCondenser Fans Check RTA* Per Circuit\nOil Analysis Per Compressor\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nCoil Cleaning Solution\nLow Temperature Sensor Calibration\nSub-cooling check\nStart Unit\nLeak Test Inspection (Positive Pressure)\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete required paper work\nService 9: RTAC (7310) Annual Maintenance\nDescription\nCustomer Notification\nInitial Site Inspection\nTechView/KestrelView Connection\nRun Service Report From TechView\nReview Diagnostics\nLock out tag out at main disconnect.\nElectrical Inspection (RTA*)\nControl Panel Calibration Check\nRemove lock out tag out at main disconnect.\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nCompressor And Oil Separator Heater Check\nFlow/Differential Mechanical Switch Check\nCompressor Check (HeliRotor Compressors)\nWater pressure drop validation.\nOil Level Check Per Compressor\nCondenser Fans Check RTA* Per Circuit\nOil Analysis Per Compressor\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nCoil Cleaning Solution\nLow Temperature Sensor Calibration\nSub-cooling check\nStart Unit\nLeak Test Inspection (Positive Pressure)\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete required paper work\n\nService 10: RTAC Seasonal Start-Up\nDescription\nCustomer Notification\nInitial Site Inspection\nStart-Up Sequence (RTAC)\nReview Diagnostics\nLock Out Tag Out (Standard)\nCondenser Fans Check RTA* Per Circuit\nCompressor And Oil Separator Heater Check\nCheck oil levels\nCondenser Coil Check\nCompressor Check (HeliRotor Compressors)\nOil return operation check\nSub-Cooling Check\nRemove Lock Out Tag Out and Restore Power\nComplete Required Paper Work\nReview Diagnostics\nComplete Required Paper Work\nService 11: Oil Filter Replacement (Per Compressor)\nDescription\nCustomer Notification\nInitial Site Inspection\nServiceman Pump Down\nEnable Front Panel Circuit Lock Out\nTransfer After Serviceman Pump Down\nOil Filter Change-RTAC, RTAE, RTUD, RTWD\nEvacuate Compressor after Repair\nOpen Valves After Pump Down or Transfer\nRun Circuit and Check Oil Pressure Drop\nOil Level Check (Screw Machines) Per Circuit\nDisable Front Panel Circuit Lock Out\nReturn Unit to Normal Operation\n\nService 12: RTAC Seasonal Shut Down\nDescription\nInitial Site Inspection\nCustomer Notification Of Chiller Shut Down Including Lock Out\nTechView/KestrelView Connection\nReview Diagnostics\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete Required Paper Work\nService 13: RTAC Seasonal Start Up\nDescription\nCustomer Notification\nReview Diagnostics\nLock Out Tag Out (Standard)\nRemove Panels Generic\nRemove Lock Out Tag Out and Restore Power\nTechView/KestrelView Connection\nVerify Pump Operation and Water Flows-Seasonal Startup\nCompressor And Oil Separator Heater Check\nStart-Up Sequence (RTAC)\nTechview/Kestrel View Disconnection\nLock Out Tag Out (Standard)\nReinstall Panels Generic\nRemove Lock Out Tag Out and Restore Power\nComplete Required Paper Work\n\nService 14: RTAC Annual (Solution Coil Cleaning)\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nLock Out Tag Out At Main Disconnect\nElectrical Inspection (RTA*)\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nFlow/Differential Mechanical Switch Check\nRemove Lock Out Tag Out At Main Disconnect\nCondenser Fans Check RTA* Per Circuit\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nOil Level Check Per Compressor\nOil Analysis Per Compressor\nLow Temperature Sensor Calibration\nControl Panel Calibration Check\nLeak Test Inspection (Positive Pressure)\nCoil Cleaning Solution\nStart Unit\nCompressor Check (HeliRotor Compressors)\nCompressor And Oil Separator Heater Check\nTechView/KestrelView Connection\nRun Service Report From TechView\nComplete Required Paper Work\n\nService 15: RTAC Quarterly Inspection\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nCondenser Fans Check RTA* Per Circuit\nLock Out Tag Out (Standard)\nVisual Electrical Inspection\nVisual Condenser Coil Check\nRemove Lock Out Tag Out\nStart Unit\nComplete Required Paper Work\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nService 16: RTAC Quarterly Inspection\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nCondenser Fans Check RTA* Per Circuit\nLock Out Tag Out (Standard)\nVisual Electrical Inspection\nRemove Lock Out Tag Out\nStart Unit\nComplete Required Paper Work\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\n\nThe NAICS code for this requirement is 811310.\nTrane is the only contractor with the capability to perform the required services on the Trane controlled chillers. The VA owned Trane Ensemble system is a proprietary control system and will only have true full compatibility with other Trane Ensemble components, software and personnel. Other contractors are unable to perform this work due to not having access to Trane software and replacement supplies. Due to the proprietary nature of the work requiring a manufacturer and installer having qualified experience in programming Trane Ensemble and having access to Trane parts and codes/software, these proprietary issues would not allow for full and open competition.\n\nThis notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement must clearly identify their capability to do so in writing by November 25, 2025 at 12 pm EST time. Response should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open this requirement to competition based upon responses to this notice is solely within the discretion of the Government.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24126Q0098","product_service_code":"J041"}],"due_at":"2025-11-25T17:00:00Z","due_date":"2025-11-25","closes_at":"2025-11-25T17:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","state":"MA","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":"description","state_evidence":"EDICAL CENTER, 940 BELMONT STREET, BROCKTON MA 02301","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-22T01:12:50.380527Z","principal_notice_id":"7d31dd3e974d45a5bb438c19657434e2","description":{"text":"The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with TRANE U.S. Inc., for the following requirement:\n\nSTATEMENT OF WORK\nChiller Maintenance\nEQUIPMENT\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Chiller\n1\nTrane\nCGAM030B2G\nU12F30551\nEYE CLINIC\nAir-Cooled Chiller\n1\nTrane\nCGAM060A2P\nU16D54225\nBLDG 3, CH 1\nAir-Cooled Chiller\n1\nTrane\nCGAM080F2H\nU12K32472\nSPD ADDITION\nAir-Cooled Chiller\n1\nTrane\nCGAM080F2H\nU12K32473\nSPD ADDITION\nAir-Cooled Chiller\n1\nTrane\nCGAM130F2A\nU24E02145\nBUILDING 5 CH-1\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UR\nU08M02830\nBLDG 2, CH 1\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UK\nU05F02407\nBLDG 7, CH 3\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004U1\nU19E03810\nCH-2\n\nSCOPE OF WORK\nThe Contractor shall provide all supervision, personnel, material, parts, equipment, supplies, labor, and transportation in performing basic preventive maintenance on the chiller systems and equipment listed in this Statement of Work located at the Department of Veterans Affairs Medical Center, 940 Belmont Street, Brockton MA 02301 in accordance with all terms and conditions of this task order and accepted quotation.\nPeriod of Performance: This will be a firm-fixed-price, base year plus four option years task order.\n\nThe following is the scope of services to be performed on Covered Equipment. Items marked with an X are included in this contract.\n\nServices Included\nCooling Seasonal Service\nX\nSeasonal Start-up\nX\nOperating Inspections Qty\nX\nSystem Shutdown\nX\nAnnual Coil Cleaning Seasonal Maintenance\n\nServices Included\nLabor and Materials for Covered Equipment\nX\nScheduled Maintenance Labor\nX\nScheduled Maintenance Parts and Materials\n\nServices Included\nPredictive Testing and Analysis for Covered Equipment Chiller(s) Only\nX\nSpectrographic Oil Analysis.\nX\nRefrigerant Analysis Provides early warning of internal failure.\nX\nKestrelView Analysis Requires Trane laptop and Trane software\nX\nOil Removal and Disposal by Trane by EPA Guidelines\n\nServices Included\nAdditional Services\nX\nAir Cooled Condenser Coil Cleaning once per year\n\nVA Brockton Hospital Equipment\n\nThe following \"Covered Equipment\" will be serviced at VA Hospital Brockton:\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UK\nU05F02407\nBLDG 7, CH 3\n\nService Description\nQuantity Per Term\nOil Sample/Spectrographic Analysis for RTAC (Service 1)\n1\nRTAC (7310) Annual Maintenance (Service 8)\n1\nRTAC Seasonal Start-Up (Service 10)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Quarterly Inspection (Service 15)\n4\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UR\nU08M02830\nBLDG 2, CH 1\n\nService Description\nQuantity Per Term\nOil Sample/Spectrographic Analysis for RTAC (Service 1)\n1\nRTAC (7310) Annual Maintenance (Service 9)\n1\nRTAC Seasonal Start-Up (Service 10)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Quarterly Inspection (Service 15)\n4\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM030B2G\nU12F30551\nEYE CLINIC\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM060A2P\nU16D54225\nBLDG 3, CH 1\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM080F2H\nU12K32472\nSPD ADDITION\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM080F2H\nU12K32473\nSPD ADDITION\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM130F2A\nU24E02145\nBUILDING 5 CH-1\n\nService Description\nQuantity Per Term\nCGAM Oil sample/analysis (Service 2)\n1\nAir Cooled Scroll Seasonal Start Up (Service 3)\n1\nCGAM Coil Cleaning (Service 4)\n1\nCGAM Quarterly Inspection (Service 5)\n4\nAir Cooled Scroll Seasonal Shut Down (Service 6)\n1\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM) - Brazil\n1\nTrane\nRTAC2004U1\nU19E03810\nCH-2\n\nService Description\nQuantity Per Term\nR MACHINE REF SAMPLE (Service 7)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Seasonal Start Up (Service 13)\n1\nRTAC Annual (Solution Coil Cleaning) (Service 14)\n1\nRTAC Quarterly Inspection (Service 16)\n4\n\nSERVICE FLOW DETAILS\nService 1: Oil Sample/Spectrographic Analysis for RTAC\nDescription\nPull oil sample for spectrographic analysis.\nService 2: CGAM Oil sample/analysis\nDescription\nPull oil sample for spectrographic analysis.\nService 3: Air Cooled Scroll Seasonal Start Up\nDescription\nCustomer Notification\nInitial Site Safety Inspection\nLock Out Tag Out (Standard)\nElectrical Inspection - Control Panel\nInspect Strainer and Pump - BPHE Seasonal Startup\nRemove LOTO and Check Heater Operation\nCompressor Oil Level Pre-Start\nTechView/KestrelView Connection\nPre-Start Chiller Check CGAM\nSeasonal Start Unit-CGAM\nCompressor Oil Level Check\nService 4: CGAM Coil Cleaning\nDescription\nCustomer Notification\nInitial Site Safety Inspection\nLock Out Tag Out (Standard)\nCoil Cleaning Solution\nRemove Lock Out Tag Out\nReturn Unit to Normal Operation\n\nService 5: CGAM Quarterly Inspection\nDescription\nCustomer Notification of Unit Maintenance\nVisual Condenser Coil Check\nShut Down Unit\nCompressor Oil Level Check- Air-Cooled Scroll\nReturn Unit to Normal Operation\nTechView/KestrelView Connection\nReview Diagnostics\nCheck Fans for Rubbing\nCheck EXV Sight Glass\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\n\nService 6: Air Cooled Scroll Seasonal Shut Down\nDescription\nInitial Site Inspection\nReview Diagnostics (Standard)\nLock Out Tag Out (Standard)\nCheck Heater Strips\n\nService 7: R MACHINE REF SAMPLE\nDescription\nR MACHINE REF SAMPLE\nPull oil sample for spectrographic analysis.\n\nService 8: RTAC (7310) Annual Maintenance\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nLock out tag out at main disconnect.\nElectrical Inspection (RTA*)\nControl Panel Calibration Check\nRemove lock out tag out at main disconnect.\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nCompressor And Oil Separator Heater Check\nFlow/Differential Mechanical Switch Check\nCompressor Check (HeliRotor Compressors)\nWater pressure drop validation.\nOil Level Check Per Compressor\nCondenser Fans Check RTA* Per Circuit\nOil Analysis Per Compressor\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nCoil Cleaning Solution\nLow Temperature Sensor Calibration\nSub-cooling check\nStart Unit\nLeak Test Inspection (Positive Pressure)\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete required paper work\nService 9: RTAC (7310) Annual Maintenance\nDescription\nCustomer Notification\nInitial Site Inspection\nTechView/KestrelView Connection\nRun Service Report From TechView\nReview Diagnostics\nLock out tag out at main disconnect.\nElectrical Inspection (RTA*)\nControl Panel Calibration Check\nRemove lock out tag out at main disconnect.\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nCompressor And Oil Separator Heater Check\nFlow/Differential Mechanical Switch Check\nCompressor Check (HeliRotor Compressors)\nWater pressure drop validation.\nOil Level Check Per Compressor\nCondenser Fans Check RTA* Per Circuit\nOil Analysis Per Compressor\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nCoil Cleaning Solution\nLow Temperature Sensor Calibration\nSub-cooling check\nStart Unit\nLeak Test Inspection (Positive Pressure)\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete required paper work\n\nService 10: RTAC Seasonal Start-Up\nDescription\nCustomer Notification\nInitial Site Inspection\nStart-Up Sequence (RTAC)\nReview Diagnostics\nLock Out Tag Out (Standard)\nCondenser Fans Check RTA* Per Circuit\nCompressor And Oil Separator Heater Check\nCheck oil levels\nCondenser Coil Check\nCompressor Check (HeliRotor Compressors)\nOil return operation check\nSub-Cooling Check\nRemove Lock Out Tag Out and Restore Power\nComplete Required Paper Work\nReview Diagnostics\nComplete Required Paper Work\nService 11: Oil Filter Replacement (Per Compressor)\nDescription\nCustomer Notification\nInitial Site Inspection\nServiceman Pump Down\nEnable Front Panel Circuit Lock Out\nTransfer After Serviceman Pump Down\nOil Filter Change-RTAC, RTAE, RTUD, RTWD\nEvacuate Compressor after Repair\nOpen Valves After Pump Down or Transfer\nRun Circuit and Check Oil Pressure Drop\nOil Level Check (Screw Machines) Per Circuit\nDisable Front Panel Circuit Lock Out\nReturn Unit to Normal Operation\n\nService 12: RTAC Seasonal Shut Down\nDescription\nInitial Site Inspection\nCustomer Notification Of Chiller Shut Down Including Lock Out\nTechView/KestrelView Connection\nReview Diagnostics\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete Required Paper Work\nService 13: RTAC Seasonal Start Up\nDescription\nCustomer Notification\nReview Diagnostics\nLock Out Tag Out (Standard)\nRemove Panels Generic\nRemove Lock Out Tag Out and Restore Power\nTechView/KestrelView Connection\nVerify Pump Operation and Water Flows-Seasonal Startup\nCompressor And Oil Separator Heater Check\nStart-Up Sequence (RTAC)\nTechview/Kestrel View Disconnection\nLock Out Tag Out (Standard)\nReinstall Panels Generic\nRemove Lock Out Tag Out and Restore Power\nComplete Required Paper Work\n\nService 14: RTAC Annual (Solution Coil Cleaning)\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nLock Out Tag Out At Main Disconnect\nElectrical Inspection (RTA*)\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nFlow/Differential Mechanical Switch Check\nRemove Lock Out Tag Out At Main Disconnect\nCondenser Fans Check RTA* Per Circuit\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nOil Level Check Per Compressor\nOil Analysis Per Compressor\nLow Temperature Sensor Calibration\nControl Panel Calibration Check\nLeak Test Inspection (Positive Pressure)\nCoil Cleaning Solution\nStart Unit\nCompressor Check (HeliRotor Compressors)\nCompressor And Oil Separator Heater Check\nTechView/KestrelView Connection\nRun Service Report From TechView\nComplete Required Paper Work\n\nService 15: RTAC Quarterly Inspection\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nCondenser Fans Check RTA* Per Circuit\nLock Out Tag Out (Standard)\nVisual Electrical Inspection\nVisual Condenser Coil Check\nRemove Lock Out Tag Out\nStart Unit\nComplete Required Paper Work\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nService 16: RTAC Quarterly Inspection\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nCondenser Fans Check RTA* Per Circuit\nLock Out Tag Out (Standard)\nVisual Electrical Inspection\nRemove Lock Out Tag Out\nStart Unit\nComplete Required Paper Work\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\n\nThe NAICS code for this requirement is 811310.\nTrane is the only contractor with the capability to perform the required services on the Trane controlled chillers. The VA owned Trane Ensemble system is a proprietary control system and will only have true full compatibility with other Trane Ensemble components, software and personnel. Other contractors are unable to perform this work due to not having access to Trane software and replacement supplies. Due to the proprietary nature of the work requiring a manufacturer and installer having qualified experience in programming Trane Ensemble and having access to Trane parts and codes/software, these proprietary issues would not allow for full and open competition.\n\nThis notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement must clearly identify their capability to do so in writing by November 25, 2025 at 12 pm EST time. Response should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open this requirement to competition based upon responses to this notice is solely within the discretion of the Government.","html":"The Department of Veterans Affairs, Networking Contracting Office (NCO 01) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with TRANE U.S. Inc., for the following requirement:\n\nSTATEMENT OF WORK\nChiller Maintenance\nEQUIPMENT\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Chiller\n1\nTrane\nCGAM030B2G\nU12F30551\nEYE CLINIC\nAir-Cooled Chiller\n1\nTrane\nCGAM060A2P\nU16D54225\nBLDG 3, CH 1\nAir-Cooled Chiller\n1\nTrane\nCGAM080F2H\nU12K32472\nSPD ADDITION\nAir-Cooled Chiller\n1\nTrane\nCGAM080F2H\nU12K32473\nSPD ADDITION\nAir-Cooled Chiller\n1\nTrane\nCGAM130F2A\nU24E02145\nBUILDING 5 CH-1\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UR\nU08M02830\nBLDG 2, CH 1\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UK\nU05F02407\nBLDG 7, CH 3\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004U1\nU19E03810\nCH-2\n\nSCOPE OF WORK\nThe Contractor shall provide all supervision, personnel, material, parts, equipment, supplies, labor, and transportation in performing basic preventive maintenance on the chiller systems and equipment listed in this Statement of Work located at the Department of Veterans Affairs Medical Center, 940 Belmont Street, Brockton MA 02301 in accordance with all terms and conditions of this task order and accepted quotation.\nPeriod of Performance: This will be a firm-fixed-price, base year plus four option years task order.\n\n\n\nThe following is the scope of services to be performed on Covered Equipment. Items marked with an  X  are included in this contract.\n\n\n\nServices Included\nCooling Seasonal Service\nX\nSeasonal Start-up\nX\nOperating Inspections Qty\nX\nSystem Shutdown\nX\nAnnual Coil Cleaning Seasonal Maintenance\n\n\nServices Included\nLabor and Materials for Covered Equipment\nX\nScheduled Maintenance Labor\nX\nScheduled Maintenance Parts and Materials\n\nServices Included\nPredictive Testing and Analysis for Covered Equipment Chiller(s) Only\nX\nSpectrographic Oil Analysis.\nX\nRefrigerant Analysis   Provides early warning of internal failure.\nX\nKestrelView  Analysis   Requires Trane laptop and Trane software\nX\nOil Removal and Disposal by Trane by EPA Guidelines\n\nServices Included\nAdditional Services\nX\nAir Cooled Condenser Coil Cleaning once per year\n\nVA Brockton Hospital Equipment\n\nThe following \"Covered Equipment\" will be serviced at VA Hospital Brockton:\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UK\nU05F02407\nBLDG 7, CH 3\n\nService Description\nQuantity Per Term\nOil Sample/Spectrographic Analysis for RTAC (Service 1)\n1\nRTAC (7310) Annual Maintenance (Service 8)\n1\nRTAC Seasonal Start-Up (Service 10)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Quarterly Inspection (Service 15)\n4\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM)\n1\nTrane\nRTAC2004UR\nU08M02830\nBLDG 2, CH 1\n\nService Description\nQuantity Per Term\nOil Sample/Spectrographic Analysis for RTAC (Service 1)\n1\nRTAC (7310) Annual Maintenance (Service 9)\n1\nRTAC Seasonal Start-Up (Service 10)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Quarterly Inspection (Service 15)\n4\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM030B2G\nU12F30551\nEYE CLINIC\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM060A2P\nU16D54225\nBLDG 3, CH 1\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM080F2H\nU12K32472\nSPD ADDITION\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM080F2H\nU12K32473\nSPD ADDITION\nAir-Cooled Chiller, Scroll Compressors\n1\nTrane\nCGAM130F2A\nU24E02145\nBUILDING 5 CH-1\n\nService Description\nQuantity Per Term\nCGAM Oil sample/analysis (Service 2)\n1\nAir Cooled Scroll Seasonal Start Up (Service 3)\n1\nCGAM Coil Cleaning (Service 4)\n1\nCGAM Quarterly Inspection (Service 5)\n4\nAir Cooled Scroll Seasonal Shut Down (Service 6)\n1\n\nEquipment\nQty\nManufacturer\nModel Number\nSerial Number\nAsset Tag\nAir-Cooled Series R(TM) - Brazil\n1\nTrane\nRTAC2004U1\nU19E03810\nCH-2\n\nService Description\nQuantity Per Term\nR MACHINE REF SAMPLE (Service 7)\n1\nOil Filter Replacement (Per Compressor) (Service 11)\n1\nRTAC Seasonal Shut Down (Service 12)\n1\nRTAC Seasonal Start Up (Service 13)\n1\nRTAC Annual (Solution Coil Cleaning) (Service 14)\n1\nRTAC Quarterly Inspection (Service 16)\n4\n\nSERVICE FLOW DETAILS\nService 1: Oil Sample/Spectrographic Analysis for RTAC\nDescription\nPull oil sample for spectrographic analysis.\nService 2: CGAM Oil sample/analysis\nDescription\nPull oil sample for spectrographic analysis.\nService 3: Air Cooled Scroll Seasonal Start Up\nDescription\nCustomer Notification\nInitial Site Safety Inspection\nLock Out Tag Out (Standard)\nElectrical Inspection - Control Panel\nInspect Strainer and Pump - BPHE Seasonal Startup\nRemove LOTO and Check Heater Operation\nCompressor Oil Level Pre-Start\nTechView/KestrelView Connection\nPre-Start Chiller Check CGAM\nSeasonal Start Unit-CGAM\nCompressor Oil Level Check\nService 4: CGAM Coil Cleaning\nDescription\nCustomer Notification\nInitial Site Safety Inspection\nLock Out Tag Out (Standard)\nCoil Cleaning Solution\nRemove Lock Out Tag Out\nReturn Unit to Normal Operation\n\nService 5: CGAM Quarterly Inspection\nDescription\nCustomer Notification of Unit Maintenance\nVisual Condenser Coil Check\nShut Down Unit\nCompressor Oil Level Check- Air-Cooled Scroll\nReturn Unit to Normal Operation\nTechView/KestrelView Connection\nReview Diagnostics\nCheck Fans for Rubbing\nCheck EXV Sight Glass\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\n\nService 6: Air Cooled Scroll Seasonal Shut Down\nDescription\nInitial Site Inspection\nReview Diagnostics (Standard)\nLock Out Tag Out (Standard)\nCheck Heater Strips\n\nService 7: R MACHINE REF SAMPLE\nDescription\nR MACHINE REF SAMPLE\nPull oil sample for spectrographic analysis.\n\nService 8: RTAC (7310) Annual Maintenance\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nLock out tag out at main disconnect.\nElectrical Inspection (RTA*)\nControl Panel Calibration Check\nRemove lock out tag out at main disconnect.\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nCompressor And Oil Separator Heater Check\nFlow/Differential Mechanical Switch Check\nCompressor Check (HeliRotor Compressors)\nWater pressure drop validation.\nOil Level Check Per Compressor\nCondenser Fans Check RTA* Per Circuit\nOil Analysis Per Compressor\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nCoil Cleaning Solution\nLow Temperature Sensor Calibration\nSub-cooling check\nStart Unit\nLeak Test Inspection (Positive Pressure)\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete required paper work\nService 9: RTAC (7310) Annual Maintenance\nDescription\nCustomer Notification\nInitial Site Inspection\nTechView/KestrelView Connection\nRun Service Report From TechView\nReview Diagnostics\nLock out tag out at main disconnect.\nElectrical Inspection (RTA*)\nControl Panel Calibration Check\nRemove lock out tag out at main disconnect.\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nCompressor And Oil Separator Heater Check\nFlow/Differential Mechanical Switch Check\nCompressor Check (HeliRotor Compressors)\nWater pressure drop validation.\nOil Level Check Per Compressor\nCondenser Fans Check RTA* Per Circuit\nOil Analysis Per Compressor\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nCoil Cleaning Solution\nLow Temperature Sensor Calibration\nSub-cooling check\nStart Unit\nLeak Test Inspection (Positive Pressure)\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete required paper work\n\nService 10: RTAC Seasonal Start-Up\nDescription\nCustomer Notification\nInitial Site Inspection\nStart-Up Sequence (RTAC)\nReview Diagnostics\nLock Out Tag Out (Standard)\nCondenser Fans Check RTA* Per Circuit\nCompressor And Oil Separator Heater Check\nCheck oil levels\nCondenser Coil Check\nCompressor Check (HeliRotor Compressors)\nOil return operation check\nSub-Cooling Check\nRemove Lock Out Tag Out and Restore Power\nComplete Required Paper Work\nReview Diagnostics\nComplete Required Paper Work\nService 11: Oil Filter Replacement (Per Compressor)\nDescription\nCustomer Notification\nInitial Site Inspection\nServiceman Pump Down\nEnable Front Panel Circuit Lock Out\nTransfer After Serviceman Pump Down\nOil Filter Change-RTAC, RTAE, RTUD, RTWD\nEvacuate Compressor after Repair\nOpen Valves After Pump Down or Transfer\nRun Circuit and Check Oil Pressure Drop\nOil Level Check (Screw Machines) Per Circuit\nDisable Front Panel Circuit Lock Out\nReturn Unit to Normal Operation\n\nService 12: RTAC Seasonal Shut Down\nDescription\nInitial Site Inspection\nCustomer Notification Of Chiller Shut Down Including Lock Out\nTechView/KestrelView Connection\nReview Diagnostics\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nComplete Required Paper Work\nService 13: RTAC Seasonal Start Up\nDescription\nCustomer Notification\nReview Diagnostics\nLock Out Tag Out (Standard)\nRemove Panels Generic\nRemove Lock Out Tag Out and Restore Power\nTechView/KestrelView Connection\nVerify Pump Operation and Water Flows-Seasonal Startup\nCompressor And Oil Separator Heater Check\nStart-Up Sequence (RTAC)\nTechview/Kestrel View Disconnection\nLock Out Tag Out (Standard)\nReinstall Panels Generic\nRemove Lock Out Tag Out and Restore Power\nComplete Required Paper Work\n\nService 14: RTAC Annual (Solution Coil Cleaning)\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nLock Out Tag Out At Main Disconnect\nElectrical Inspection (RTA*)\nCompressor Starter Inspection (Wye-Delta Closed Transition) Series R Air Cooled\nFlow/Differential Mechanical Switch Check\nRemove Lock Out Tag Out At Main Disconnect\nCondenser Fans Check RTA* Per Circuit\nVisual Condenser Coil Check\nOil Return Operation Check Per Circuit\nOil Level Check Per Compressor\nOil Analysis Per Compressor\nLow Temperature Sensor Calibration\nControl Panel Calibration Check\nLeak Test Inspection (Positive Pressure)\nCoil Cleaning Solution\nStart Unit\nCompressor Check (HeliRotor Compressors)\nCompressor And Oil Separator Heater Check\nTechView/KestrelView Connection\nRun Service Report From TechView\nComplete Required Paper Work\n\nService 15: RTAC Quarterly Inspection\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nCondenser Fans Check RTA* Per Circuit\nLock Out Tag Out (Standard)\nVisual Electrical Inspection\nVisual Condenser Coil Check\nRemove Lock Out Tag Out\nStart Unit\nComplete Required Paper Work\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\nService 16: RTAC Quarterly Inspection\nDescription\nCustomer Notification\nInitial Site Inspection\nReview Diagnostics\nCondenser Fans Check RTA* Per Circuit\nLock Out Tag Out (Standard)\nVisual Electrical Inspection\nRemove Lock Out Tag Out\nStart Unit\nComplete Required Paper Work\nTechView/KestrelView Connection\nRun Service Report From TechView\nTechview/Kestrel View Disconnection\n\n\nThe NAICS code for this requirement is 811310.\nTrane is the only contractor with the capability to perform the required services on the Trane controlled chillers.  The VA owned Trane Ensemble system is a proprietary control system and will only have true full compatibility with other Trane Ensemble components, software and personnel. Other contractors are unable to perform this work due to not having access to Trane software and replacement supplies.  Due to the proprietary nature of the work requiring a manufacturer and installer having qualified experience in programming Trane Ensemble and having access to Trane parts and codes/software, these proprietary issues would not allow for full and open competition.  \n\nThis notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement must clearly identify their capability to do so in writing by November 25, 2025 at 12 pm EST time. Response should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination not to open this requirement to competition based upon responses to this notice is solely within the discretion of the Government.","origin":"detail"},"contacts":[{"name":"Issa Shawki","role":"primary","email":"issa.shawki@va.gov","phone":"774-826-3192","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"cc40eccdc101449da0c9a16a7088b07c","name":"36C24126Q0098.docx","kind":"file","mime_type":".docx","size_bytes":45656,"posted_at":"2025-11-20T18:31:59.929Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cc40eccdc101449da0c9a16a7088b07c/download","mirrored":false}],"awards":[],"related":[{"key":"36C24127Q0084","latest_notice_id":"939b8f3021be4a75ae5972b0c7ffb9ae","title":"X1EA--CWM VA Police Use of shooting range.","solicitation_number":"36C24127Q0084","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"611699","psc":"X1EA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24127Q0017","latest_notice_id":"d60676ea33af4051b90a1953ab55743e","title":"S201--36C24127Q0017 Windows Washing Service Amendment 0002","solicitation_number":"36C24127Q0017","notice_type":"k","first_type":"k","first_posted":"2026-10-26","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"561720","psc":"S201","set_aside":"SDVOSBC","state":"MA","county":"25017","county_name":"Middlesex County","city":"2501704615","city_name":"Bedford","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24127Q0044","latest_notice_id":"a2f2fe28c1ec4687b2a2955cf947935e","title":"9140--Togus Fuel Oil and Diesel Delivery","solicitation_number":"36C24127Q0044","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"324110","psc":"9140","set_aside":"SBA","state":"ME","county":"23011","county_name":"Kennebec County","city":"2302100","city_name":"Augusta","country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"04330","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24127Q0076","latest_notice_id":"bb30bc78067840a082b5d9e12eceddd2","title":"Q601--Sources sought Boston Medical Coding Period of Period 01/01/2027-04/01/2027","solicitation_number":"36C24127Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541219","psc":"Q601","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24127Q0030","latest_notice_id":"10c3d2d3d0c543179707f8cc9448f701","title":"J061--Eaton Powerware System Replacement","solicitation_number":"36C24127Q0030","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J061","set_aside":"SDVOSBC","state":"NH","county":"33011","county_name":"Hillsborough County","city":"3345140","city_name":"Manchester","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"36C24127Q0067","latest_notice_id":"26e4c95d67154092a7784cd9eacb6e8f","title":"Ice Machine Disinfection Maintenance Agreement with 4 (1-year option periods)","solicitation_number":"36C24127Q0067","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-12-03T17:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J041","set_aside":"SDVOSBC","state":"MA","county":"25017","county_name":"Middlesex County","city":"2501704615","city_name":"Bedford","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"W50S6Y27RA002","latest_notice_id":"87cba3e75e354d12990453adb59fe26e","title":"Halon Bottle Inspection","solicitation_number":"W50S6Y27RA002","notice_type":"o","first_type":"r","first_posted":"2026-11-07","last_posted":"2026-11-20","notices":6,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W50S6Y","office_name":"W7M2 USPFO ACTIVITY FLANG 125","naics":"811310","psc":"J042","set_aside":"SBA","state":"FL","county":"12031","county_name":"Duval County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"},{"key":"N3225327Q0011","latest_notice_id":"e4f2bdc21bab431d8dddd03dc4c01ccf","title":"Dry Dock Flow Meter Service","solicitation_number":"N32253-27-Q-0011","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-24","notices":2,"due_at":"2026-11-27T18:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N32253","office_name":"PEARL HARBOR NAVAL SHIPYARD IMF","naics":"811310","psc":"J049","set_aside":null,"state":"HI","county":"15003","county_name":"Honolulu County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":56,"indexable":false}