{"canonical":"https://sealedbidder.com/opportunities/36c24126q0086","key":"36C24126Q0086","url":"https://sealedbidder.com/opportunities/36c24126q0086","title":"K099--Liquid Nitrogen Safety Upgrades","solicitation_number":"36C24126Q0086","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-11-20T17:00:00Z","first_posted":"2025-11-17","last_posted":"2025-11-17","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541330","psc":"K099","set_aside":null,"place_state":"MA","place_scope":"site","site":null,"place_state_source":"sam_state_name","place_evidence":null,"place_county":"25025","place_county_name":"Suffolk County","place_city":"2507000","place_city_name":"Boston","winner":null,"award_amount":null,"publications":[{"notice_id":"12d452552312464e99f21218c586dbe9","title":"K099--Liquid Nitrogen Safety Upgrades","solicitation_number":"36C24126Q0086","notice_type":"r","base_type":"r","posted":"2025-11-17","posted_at":"2025-11-17T15:51:04.254Z","due_at":"2025-11-20T17:00:00Z","due_date":"2025-11-20","cancelled":false,"archived":true,"archive_date":"2026-01-19","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/12d452552312464e99f21218c586dbe9/view","enriched":true,"history":[{"index":3,"title":"K099--Liquid Nitrogen Safety Upgrades","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-17T15:51:04.254Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"12d452552312464e99f21218c586dbe9","solicitation_number":"36C24126Q0086"}]}],"latest_notice_id":"12d452552312464e99f21218c586dbe9","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-11-17","posted_at":"2025-11-17T15:51:04.254Z","created_at":"2025-11-17T15:50:58.799Z","modified_at":"2026-01-20T05:00:07.577Z","response_deadline":{"raw":"2025-11-20T12:00:00-05:00","utc":"2025-11-20T17:00:00Z","date":"2025-11-20","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/12d452552312464e99f21218c586dbe9/view"},"naics":{"codes":["541330"],"primary":"541330"},"title":"K099--Liquid Nitrogen Safety Upgrades","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-01-19","archive_type":"auto_custom"},"history":[{"index":3,"title":"K099--Liquid Nitrogen Safety Upgrades","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-11-17T15:51:04.254Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"12d452552312464e99f21218c586dbe9","solicitation_number":"36C24126Q0086"}],"contacts":[{"name":"Issa Shawki","role":"primary","email":"issa.shawki@va.gov","phone":"774-826-3192","title":"Contracting Officer"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"12d452552312464e99f21218c586dbe9","lineage_id":"12d452552312464e99f21218c586dbe9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-22T02:52:57.141416188Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"af1f6dc32144754a194be8359e42e57af6244dd8024b87515376fe2be1482ee6","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-22T02:52:57.141416188Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation. \nIf a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation\nThe purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 541330, (K099) with a size standard $25.5 million. The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing Liquid Nitrogen Safety Upgrades per the Statement of WorkÂ below. \nThis Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are encouraged to submit information relative to their capabilities to fulfill this requirement, in the form of a statement that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy.\nSubmission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this Sources Sought Notice by 12PM EST, November 20, 2025. All responses under this Sources Sought Notice must be emailed to issa.shawki@va.gov with Sources Sought #36C24126Q0086 in the subject line. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\nInterested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format.\nAttachment 1\nSources Sought Worksheet\nQUALIFICATION INFORMATION:\nCompany / Institute Name: _______________________________________________________\nAddress: ______________________________________________________________________\nPhone Number: ________________________________________________________________\nPoint of Contact: _______________________________________________________________\nE-mail Address: ________________________________________________________________\nUnique Entity Identifier (UEI) #:Â ___________________________________________________\nCAGE Code: __________________________________________________________________\nSAM Registered: (Y / N)\nOther available contract vehicles applicable to this sources sought (GSA/FSS/NASA SEWP/ETC): __________________________________________________________________\n______________________________________________________________________________\n______________________________________________________________________________\nSOCIO-ECONOMIC STATUS:\nVIP Verified SDVOSB: (Y / N)   \nVIP Verified VOSB: (Y / N)\n8(a): (Y / N)\nHUBZone: (Y / N)\nEconomically Disadvantaged Women-Owned Small Business: (Y / N)\nWomen-Owned Small Business: (Y / N)\nSmall Business: (Y / N)\nNOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION.\nSTATEMENT OF WORK\nA. GENERAL INFORMATION\n1. Item: Enhancements to the VA Central Biorepository (VACB) liquid nitrogen system to provide\na fail-safe environment in case of a liquid nitrogen leak in the Building. The design of the\nenhanced liquid nitrogen (LN2) system must meet the following criteria:\na. Be simple to troubleshoot and easy to reestablish LN2 functionality within a period of\nless than an hour following a false positive event that led to a LN2 shutdown.\nb. The system must NOT be complex as to require an expert or extensive amount of time to\ntroubleshoot before functionality can be reestablished.\nc. System must be designed so that a lab personnel can operate with minimal training.\nd. System shall contain a fail-safe mechanism in the event of a liquid nitrogen leak.\n2. Purpose: The purpose of this contract is to provide certain enhancements necessary to provide a\nfail-safe environment in the VACB\n3. Scope of Work: The contractor shall provide all resources necessary to accomplish the\ndeliverables described in this performance work statement. The contractor should have expertise\nin cryogenics with positive past performance documented in the CPARS system. The Medical\nCenter requires the services of a qualified contractor which shall provide a fail-safe environment\nin case of a liquid nitrogen leak in the Building.\nThe VA Central Biorepository (VACB) stores millions of blood samples in a large robotic nitro\nstore, several cryogenic liquid nitrogen tanks and mechanical freezers. The cryogenic tanks and\nthe robotic nitrostore are supplied with liquid nitrogen from a large liquid nitrogen tank (11,000-\ngallon capacity) that is located outside the building at VABHS. The piping from this external\ntank to the nitrostore and cryogenic tanks was installed by Maccomber Cryogenics around 2011.\nCurrently there are several oxygen sensors located within the Biorepository that are tied into the\nalarm systems. When excess liquid nitrogen enters the laboratory the oxygen concentration in the\nroom can drop below levels necessary to sustain life. Currently, the only way to stop the flow of\nliquid nitrogen is to manually shut off the supply line at the liquid nitrogen tank. If the leak\nhappens during off hours this can take hours leading to an extremely dangerous situation,\nespecially for non-laboratory staff like police or engineering staff that might enter the room to\naddress the alarm. To mitigate risk to staff, under this contract the contractor shall:\nÂ· Add safety enhancements that would automatically cut-off the liquid nitrogen supply\nfrom the main external tank when the oxygen concentration drops below the\nrecommended set-point.\nÂ· Add 4 E-stop push button stations,\nÂ· Add three (3) additional oxygen sensors,\nÂ· Add emergency shutoff valves\nÂ· Add emergency inlet port for the nitrostore freezer and the cryotank farm room.\nÂ· All electrical signals emanating from the above mentioned instruments, including an\nexisting Tox Gard ii located in the nitrostore building, shall be connected to the main\noxygen monitoring and control panel and be integrated with the Biorepository s Alarm\nsystems as well as to the building s AEM alarm output system.\n4. Background: The VACB processes and stores specimens for clinical trials run by the VA\nCooperative Studies Program. The Biorepository is involved in a large-scale genomics project\nthat will require processing and storing of up to 1,000 samples a day in addition to existing and\nongoing processing for other Cooperative Studies Program projects. The Biorepository stores\nmillions of specimens donated by veterans for clinical research in a large robotic store known as\nthe nitrostore, cryogenic tanks and mechanical freezers. The nitrostore and cryogenic tanks are\ncooled with liquid nitrogen which is supplied from a large external liquid nitrogen tank located\noutside the building. Currently there are two shut off valves that are located near the external\nliquid nitrogen tank that would shut off the supply of liquid nitrogen to the nitrostore building and\nto the cryogenic tank room. The nitrostore requires a constant supply of liquid nitrogen, so a long\nshut off of the liquid nitrogen supply to the nitrostore would be detrimental to the stored\nspecimens. We can shut off liquid nitrogen supply to the cryotank room if all the cryotanks are\nfilled with appropriate amounts of liquid nitrogen. There have been several incidences of excess\nnitrogen releases in the laboratory where the oxygen concentration in the VACB dropped below\nthe set-point of the oxygen sensors. This was due to both equipment malfunction and filling of the\nliquid nitrogen tank. All events occurred during off hours. The drop in oxygen concentration is\nnot compatible with human life. While biorepository staff are well trained to handle this event,\nfirst responders such as police or engineering staff who respond to the low oxygen alarm may\nenter the Biorepository without realizing the consequences.\n5. Performance Period: Four months. No options.\n6. Type of Contract: Firm-fixed price Service contract\n7. Place of Performance: Service performed at VA Boston Healthcare System, 150 S. Huntington\nAvenue, Jamaica Plain, MA 02130. Room RB-8\n8. General Requirements:\nAfter several discussions the Biorepository and the local engineering service decided to go with\npneumatic valves. The pressure required to operate these pneumatically controlled valves will be\nenabled with two nitrogen gas cylinders which will be placed near the liquid nitrogen tank. These\nnitrogen gas cylinders should be protected from external elements and secured properly by the\nvendor. In addition, the vendor shall provide an emergency inlet port that will supply liquid\nnitrogen to the nitrostore and the cryotank farm when the system is down for maintenance. In\naddition, we would require the vendor to provide all engineering services, documentation\ndeliverables, instrument installation and configuration, required electrical and mechanical\ninstallation, project management at site and internally, validation of the system, necessary\ntraining and a one year system warranty that includes parts and labor for the system. The figure\nbelow shows how the two valves are controlled by the two N2 cylinders. We will not use LN2\nsupply pressure to activate these valves.\n\n9. Requested Enhancements\nControl System Scope of Supply\na. One (1) Main O2 Monitoring & LN2 Isolation Control Panel\nb. Two (2) Local O2 Monitoring Control Panels [for redundant O2 monitors]\nc. Three (3) MSA TG5000 O2 Monitors with remote sensor kits\nd. Three (3) MSA Toxguard II remote sensor kits\ne. Four (4) NEMA 4 Lighted E-Stop Pushbutton Stations\nf. Two (2) LN2 Electronic Pressure Transmitters with manifold ranged 0 - 60 PSIG\ng. One (1) N2 Electronic Pressure Transmitter with manifold ranged 0 - 3,000 PSIG\nh. One (1) custom engineered LN2 valve manifold with the following features:\no All piping vacuum insulated for LN2 service\no Dual LN2 isolation valves, spring fail-closed pneumatic operator, 24VDC solenoids, DPDT Open\n& Close Limit switches and manual override capability\no Pressure relief valves in all pipe sections downstream of valves\no Emergency supply ports for the Nitrostore and Cryotank LN2 supply piping\no Taps for LN2 tank supply and building LN2 delivery pressure transmitters\ni. N2 tank control and monitoring system with the following features:\no Parker Gas Change-Over System unit that allows depressurizing and swapping tanks without\nloss of N2 pressure/flow. When one is empty the unit will automatically start drawing from the\nsecond tank.\no Low pressure switches for each tank s inlet connection\no Outdoor weather-shielded lockable cage with room for six (6) tanks total\no Two (2) 300CF series replaceable tanks of N2\nEngineering Services\nj. Design and Drafting of Local O2 Monitoring Panel\nk. Design and Drafting of Main O2 Monitoring & LN2 Isolation Panel\nl. Programming of PLC controller and HMI Monitoring Screens\nm. Design and drafting of custom LN2 valve manifold and associated site piping\nn. Design and drafting of N2 tank monitoring and control system\no. Design coordination with AEM and Rees Scientific\np. Factory Acceptance Test (FAT)\nq. Site commissioning, testing and system validation\nDocumentation Deliverables\nr. Control panel drawings and equipment data sheets\ns. Control system overview drawings\nt. LN2 valve manifold piping and instrumentation drawing (P&ID)\nu. N2 Tank control and monitoring system\nv. O2 monitoring and LN2 isolation system validation test plan\nInstrumentation Installation and Configuration\nw. Install and configure the following equipment and instruments:\no MSA TG5000 O2 monitors and remote sensor kits\no Remote O2 sensor kits for existing Toxguard IIs\no LN2 supply and delivery pressure transmitters\no N2 gas tank A pressure transmitter\no N2 gas tank pressure switches\nx. Configure the existing MSA Toxguard IIs and rewire the 115VAC power to be from the UPS in the Main\nO2 Monitoring and LN2 Isolation Panel.\nElectrical Installation\ny. Installation of NECI local and main control panels, remote E-stop stations, and O2 monitors\nz. Installation of O2 sensor extension kits on existing Toxguard II O2 monitors\naa. Supply, installation and wiring termination of all control cables, and power cables shown on the System\nOverview drawing.\nbb. Power and signal wiring to the AEP and REES Scientific panels.\ncc. Supply, installation and wiring termination of control cables to existing alarm sirens and strobe lights\nMechanical Installation\ndd. Installation of LN2 pressure transmitters and N2 pressure transmitter, transmitter sunshade and\nassociated impulse tubing.\nee. Installation of the custom outdoor LN2 valve and instrumentation manifold assembly\nff. Moving of the Cryotank Room LN2 piping take-off to be downstream of the isolation valves.\ngg. Addition of on-pad and off-pad pipe supports including foundations as required.\nhh. Supply and install N2 tank enclosure, N2 gas tank Changeover System and associated piping.\nInternal and On-Site Project Management\nii. Internal project management for detailed system design, parts procurement and regular updates to the\nVA.\njj. Management of electrical, LN2 piping and third-party suppliers (LN2 Manifold Supplier, AEM, Rees\nScientific)\nkk. One-site construction and installation management\nSystem Warranty\nll. Include a one-year parts and labor warranty for the system.","text":"This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation.\nIf a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation\nThe purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 541330, (K099) with a size standard $25.5 million. The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing Liquid Nitrogen Safety Upgrades per the Statement of WorkÂ below.\nThis Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are encouraged to submit information relative to their capabilities to fulfill this requirement, in the form of a statement that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy.\nSubmission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this Sources Sought Notice by 12PM EST, November 20, 2025. All responses under this Sources Sought Notice must be emailed to issa.shawki@va.gov with Sources Sought #36C24126Q0086 in the subject line. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\nInterested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format.\nAttachment 1\nSources Sought Worksheet\nQUALIFICATION INFORMATION:\nCompany / Institute Name: _______________________________________________________\nAddress: ______________________________________________________________________\nPhone Number: ________________________________________________________________\nPoint of Contact: _______________________________________________________________\nE-mail Address: ________________________________________________________________\nUnique Entity Identifier (UEI) #:Â ___________________________________________________\nCAGE Code: __________________________________________________________________\nSAM Registered: (Y / N)\nOther available contract vehicles applicable to this sources sought (GSA/FSS/NASA SEWP/ETC): __________________________________________________________________\n______________________________________________________________________________\n______________________________________________________________________________\nSOCIO-ECONOMIC STATUS:\nVIP Verified SDVOSB: (Y / N)\nVIP Verified VOSB: (Y / N)\n8(a): (Y / N)\nHUBZone: (Y / N)\nEconomically Disadvantaged Women-Owned Small Business: (Y / N)\nWomen-Owned Small Business: (Y / N)\nSmall Business: (Y / N)\nNOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION.\nSTATEMENT OF WORK\nA. GENERAL INFORMATION\n1. Item: Enhancements to the VA Central Biorepository (VACB) liquid nitrogen system to provide\na fail-safe environment in case of a liquid nitrogen leak in the Building. The design of the\nenhanced liquid nitrogen (LN2) system must meet the following criteria:\na. Be simple to troubleshoot and easy to reestablish LN2 functionality within a period of\nless than an hour following a false positive event that led to a LN2 shutdown.\nb. The system must NOT be complex as to require an expert or extensive amount of time to\ntroubleshoot before functionality can be reestablished.\nc. System must be designed so that a lab personnel can operate with minimal training.\nd. System shall contain a fail-safe mechanism in the event of a liquid nitrogen leak.\n2. Purpose: The purpose of this contract is to provide certain enhancements necessary to provide a\nfail-safe environment in the VACB\n3. Scope of Work: The contractor shall provide all resources necessary to accomplish the\ndeliverables described in this performance work statement. The contractor should have expertise\nin cryogenics with positive past performance documented in the CPARS system. The Medical\nCenter requires the services of a qualified contractor which shall provide a fail-safe environment\nin case of a liquid nitrogen leak in the Building.\nThe VA Central Biorepository (VACB) stores millions of blood samples in a large robotic nitro\nstore, several cryogenic liquid nitrogen tanks and mechanical freezers. The cryogenic tanks and\nthe robotic nitrostore are supplied with liquid nitrogen from a large liquid nitrogen tank (11,000-\ngallon capacity) that is located outside the building at VABHS. The piping from this external\ntank to the nitrostore and cryogenic tanks was installed by Maccomber Cryogenics around 2011.\nCurrently there are several oxygen sensors located within the Biorepository that are tied into the\nalarm systems. When excess liquid nitrogen enters the laboratory the oxygen concentration in the\nroom can drop below levels necessary to sustain life. Currently, the only way to stop the flow of\nliquid nitrogen is to manually shut off the supply line at the liquid nitrogen tank. If the leak\nhappens during off hours this can take hours leading to an extremely dangerous situation,\nespecially for non-laboratory staff like police or engineering staff that might enter the room to\naddress the alarm. To mitigate risk to staff, under this contract the contractor shall:\nÂ· Add safety enhancements that would automatically cut-off the liquid nitrogen supply\nfrom the main external tank when the oxygen concentration drops below the\nrecommended set-point.\nÂ· Add 4 E-stop push button stations,\nÂ· Add three (3) additional oxygen sensors,\nÂ· Add emergency shutoff valves\nÂ· Add emergency inlet port for the nitrostore freezer and the cryotank farm room.\nÂ· All electrical signals emanating from the above mentioned instruments, including an\nexisting Tox Gard ii located in the nitrostore building, shall be connected to the main\noxygen monitoring and control panel and be integrated with the Biorepository s Alarm\nsystems as well as to the building s AEM alarm output system.\n4. Background: The VACB processes and stores specimens for clinical trials run by the VA\nCooperative Studies Program. The Biorepository is involved in a large-scale genomics project\nthat will require processing and storing of up to 1,000 samples a day in addition to existing and\nongoing processing for other Cooperative Studies Program projects. The Biorepository stores\nmillions of specimens donated by veterans for clinical research in a large robotic store known as\nthe nitrostore, cryogenic tanks and mechanical freezers. The nitrostore and cryogenic tanks are\ncooled with liquid nitrogen which is supplied from a large external liquid nitrogen tank located\noutside the building. Currently there are two shut off valves that are located near the external\nliquid nitrogen tank that would shut off the supply of liquid nitrogen to the nitrostore building and\nto the cryogenic tank room. The nitrostore requires a constant supply of liquid nitrogen, so a long\nshut off of the liquid nitrogen supply to the nitrostore would be detrimental to the stored\nspecimens. We can shut off liquid nitrogen supply to the cryotank room if all the cryotanks are\nfilled with appropriate amounts of liquid nitrogen. There have been several incidences of excess\nnitrogen releases in the laboratory where the oxygen concentration in the VACB dropped below\nthe set-point of the oxygen sensors. This was due to both equipment malfunction and filling of the\nliquid nitrogen tank. All events occurred during off hours. The drop in oxygen concentration is\nnot compatible with human life. While biorepository staff are well trained to handle this event,\nfirst responders such as police or engineering staff who respond to the low oxygen alarm may\nenter the Biorepository without realizing the consequences.\n5. Performance Period: Four months. No options.\n6. Type of Contract: Firm-fixed price Service contract\n7. Place of Performance: Service performed at VA Boston Healthcare System, 150 S. Huntington\nAvenue, Jamaica Plain, MA 02130. Room RB-8\n8. General Requirements:\nAfter several discussions the Biorepository and the local engineering service decided to go with\npneumatic valves. The pressure required to operate these pneumatically controlled valves will be\nenabled with two nitrogen gas cylinders which will be placed near the liquid nitrogen tank. These\nnitrogen gas cylinders should be protected from external elements and secured properly by the\nvendor. In addition, the vendor shall provide an emergency inlet port that will supply liquid\nnitrogen to the nitrostore and the cryotank farm when the system is down for maintenance. In\naddition, we would require the vendor to provide all engineering services, documentation\ndeliverables, instrument installation and configuration, required electrical and mechanical\ninstallation, project management at site and internally, validation of the system, necessary\ntraining and a one year system warranty that includes parts and labor for the system. The figure\nbelow shows how the two valves are controlled by the two N2 cylinders. We will not use LN2\nsupply pressure to activate these valves.\n\n9. Requested Enhancements\nControl System Scope of Supply\na. One (1) Main O2 Monitoring & LN2 Isolation Control Panel\nb. Two (2) Local O2 Monitoring Control Panels [for redundant O2 monitors]\nc. Three (3) MSA TG5000 O2 Monitors with remote sensor kits\nd. Three (3) MSA Toxguard II remote sensor kits\ne. Four (4) NEMA 4 Lighted E-Stop Pushbutton Stations\nf. Two (2) LN2 Electronic Pressure Transmitters with manifold ranged 0 - 60 PSIG\ng. One (1) N2 Electronic Pressure Transmitter with manifold ranged 0 - 3,000 PSIG\nh. One (1) custom engineered LN2 valve manifold with the following features:\no All piping vacuum insulated for LN2 service\no Dual LN2 isolation valves, spring fail-closed pneumatic operator, 24VDC solenoids, DPDT Open\n& Close Limit switches and manual override capability\no Pressure relief valves in all pipe sections downstream of valves\no Emergency supply ports for the Nitrostore and Cryotank LN2 supply piping\no Taps for LN2 tank supply and building LN2 delivery pressure transmitters\ni. N2 tank control and monitoring system with the following features:\no Parker Gas Change-Over System unit that allows depressurizing and swapping tanks without\nloss of N2 pressure/flow. When one is empty the unit will automatically start drawing from the\nsecond tank.\no Low pressure switches for each tank s inlet connection\no Outdoor weather-shielded lockable cage with room for six (6) tanks total\no Two (2) 300CF series replaceable tanks of N2\nEngineering Services\nj. Design and Drafting of Local O2 Monitoring Panel\nk. Design and Drafting of Main O2 Monitoring & LN2 Isolation Panel\nl. Programming of PLC controller and HMI Monitoring Screens\nm. Design and drafting of custom LN2 valve manifold and associated site piping\nn. Design and drafting of N2 tank monitoring and control system\no. Design coordination with AEM and Rees Scientific\np. Factory Acceptance Test (FAT)\nq. Site commissioning, testing and system validation\nDocumentation Deliverables\nr. Control panel drawings and equipment data sheets\ns. Control system overview drawings\nt. LN2 valve manifold piping and instrumentation drawing (P&ID)\nu. N2 Tank control and monitoring system\nv. O2 monitoring and LN2 isolation system validation test plan\nInstrumentation Installation and Configuration\nw. Install and configure the following equipment and instruments:\no MSA TG5000 O2 monitors and remote sensor kits\no Remote O2 sensor kits for existing Toxguard IIs\no LN2 supply and delivery pressure transmitters\no N2 gas tank A pressure transmitter\no N2 gas tank pressure switches\nx. Configure the existing MSA Toxguard IIs and rewire the 115VAC power to be from the UPS in the Main\nO2 Monitoring and LN2 Isolation Panel.\nElectrical Installation\ny. Installation of NECI local and main control panels, remote E-stop stations, and O2 monitors\nz. Installation of O2 sensor extension kits on existing Toxguard II O2 monitors\naa. Supply, installation and wiring termination of all control cables, and power cables shown on the System\nOverview drawing.\nbb. Power and signal wiring to the AEP and REES Scientific panels.\ncc. Supply, installation and wiring termination of control cables to existing alarm sirens and strobe lights\nMechanical Installation\ndd. Installation of LN2 pressure transmitters and N2 pressure transmitter, transmitter sunshade and\nassociated impulse tubing.\nee. Installation of the custom outdoor LN2 valve and instrumentation manifold assembly\nff. Moving of the Cryotank Room LN2 piping take-off to be downstream of the isolation valves.\ngg. Addition of on-pad and off-pad pipe supports including foundations as required.\nhh. Supply and install N2 tank enclosure, N2 gas tank Changeover System and associated piping.\nInternal and On-Site Project Management\nii. Internal project management for detailed system design, parts procurement and regular updates to the\nVA.\njj. Management of electrical, LN2 piping and third-party suppliers (LN2 Manifold Supplier, AEM, Rees\nScientific)\nkk. One-site construction and installation management\nSystem Warranty\nll. Include a one-year parts and labor warranty for the system.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24126Q0086","place_of_performance":{"zip":"02130","city":{"name":"Boston"},"state":{"name":"MA"},"country":{"code":"USA","name":"UNITED STATES"},"street2":"150 S. Huntington Avenue"},"product_service_code":"K099"}],"due_at":"2025-11-20T17:00:00Z","due_date":"2025-11-20","closes_at":"2025-11-20T17:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","state":"MA","county":"25025","county_name":"Suffolk County","city":"2507000","city_name":"Boston","country":"USA","state_source":"sam_state_name","state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-22T03:22:15.156837Z","principal_notice_id":"12d452552312464e99f21218c586dbe9","description":{"text":"This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation.\nIf a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation\nThe purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 541330, (K099) with a size standard $25.5 million. The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing Liquid Nitrogen Safety Upgrades per the Statement of WorkÂ below.\nThis Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are encouraged to submit information relative to their capabilities to fulfill this requirement, in the form of a statement that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy.\nSubmission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this Sources Sought Notice by 12PM EST, November 20, 2025. All responses under this Sources Sought Notice must be emailed to issa.shawki@va.gov with Sources Sought #36C24126Q0086 in the subject line. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\nInterested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format.\nAttachment 1\nSources Sought Worksheet\nQUALIFICATION INFORMATION:\nCompany / Institute Name: _______________________________________________________\nAddress: ______________________________________________________________________\nPhone Number: ________________________________________________________________\nPoint of Contact: _______________________________________________________________\nE-mail Address: ________________________________________________________________\nUnique Entity Identifier (UEI) #:Â ___________________________________________________\nCAGE Code: __________________________________________________________________\nSAM Registered: (Y / N)\nOther available contract vehicles applicable to this sources sought (GSA/FSS/NASA SEWP/ETC): __________________________________________________________________\n______________________________________________________________________________\n______________________________________________________________________________\nSOCIO-ECONOMIC STATUS:\nVIP Verified SDVOSB: (Y / N)\nVIP Verified VOSB: (Y / N)\n8(a): (Y / N)\nHUBZone: (Y / N)\nEconomically Disadvantaged Women-Owned Small Business: (Y / N)\nWomen-Owned Small Business: (Y / N)\nSmall Business: (Y / N)\nNOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION.\nSTATEMENT OF WORK\nA. GENERAL INFORMATION\n1. Item: Enhancements to the VA Central Biorepository (VACB) liquid nitrogen system to provide\na fail-safe environment in case of a liquid nitrogen leak in the Building. The design of the\nenhanced liquid nitrogen (LN2) system must meet the following criteria:\na. Be simple to troubleshoot and easy to reestablish LN2 functionality within a period of\nless than an hour following a false positive event that led to a LN2 shutdown.\nb. The system must NOT be complex as to require an expert or extensive amount of time to\ntroubleshoot before functionality can be reestablished.\nc. System must be designed so that a lab personnel can operate with minimal training.\nd. System shall contain a fail-safe mechanism in the event of a liquid nitrogen leak.\n2. Purpose: The purpose of this contract is to provide certain enhancements necessary to provide a\nfail-safe environment in the VACB\n3. Scope of Work: The contractor shall provide all resources necessary to accomplish the\ndeliverables described in this performance work statement. The contractor should have expertise\nin cryogenics with positive past performance documented in the CPARS system. The Medical\nCenter requires the services of a qualified contractor which shall provide a fail-safe environment\nin case of a liquid nitrogen leak in the Building.\nThe VA Central Biorepository (VACB) stores millions of blood samples in a large robotic nitro\nstore, several cryogenic liquid nitrogen tanks and mechanical freezers. The cryogenic tanks and\nthe robotic nitrostore are supplied with liquid nitrogen from a large liquid nitrogen tank (11,000-\ngallon capacity) that is located outside the building at VABHS. The piping from this external\ntank to the nitrostore and cryogenic tanks was installed by Maccomber Cryogenics around 2011.\nCurrently there are several oxygen sensors located within the Biorepository that are tied into the\nalarm systems. When excess liquid nitrogen enters the laboratory the oxygen concentration in the\nroom can drop below levels necessary to sustain life. Currently, the only way to stop the flow of\nliquid nitrogen is to manually shut off the supply line at the liquid nitrogen tank. If the leak\nhappens during off hours this can take hours leading to an extremely dangerous situation,\nespecially for non-laboratory staff like police or engineering staff that might enter the room to\naddress the alarm. To mitigate risk to staff, under this contract the contractor shall:\nÂ· Add safety enhancements that would automatically cut-off the liquid nitrogen supply\nfrom the main external tank when the oxygen concentration drops below the\nrecommended set-point.\nÂ· Add 4 E-stop push button stations,\nÂ· Add three (3) additional oxygen sensors,\nÂ· Add emergency shutoff valves\nÂ· Add emergency inlet port for the nitrostore freezer and the cryotank farm room.\nÂ· All electrical signals emanating from the above mentioned instruments, including an\nexisting Tox Gard ii located in the nitrostore building, shall be connected to the main\noxygen monitoring and control panel and be integrated with the Biorepository s Alarm\nsystems as well as to the building s AEM alarm output system.\n4. Background: The VACB processes and stores specimens for clinical trials run by the VA\nCooperative Studies Program. The Biorepository is involved in a large-scale genomics project\nthat will require processing and storing of up to 1,000 samples a day in addition to existing and\nongoing processing for other Cooperative Studies Program projects. The Biorepository stores\nmillions of specimens donated by veterans for clinical research in a large robotic store known as\nthe nitrostore, cryogenic tanks and mechanical freezers. The nitrostore and cryogenic tanks are\ncooled with liquid nitrogen which is supplied from a large external liquid nitrogen tank located\noutside the building. Currently there are two shut off valves that are located near the external\nliquid nitrogen tank that would shut off the supply of liquid nitrogen to the nitrostore building and\nto the cryogenic tank room. The nitrostore requires a constant supply of liquid nitrogen, so a long\nshut off of the liquid nitrogen supply to the nitrostore would be detrimental to the stored\nspecimens. We can shut off liquid nitrogen supply to the cryotank room if all the cryotanks are\nfilled with appropriate amounts of liquid nitrogen. There have been several incidences of excess\nnitrogen releases in the laboratory where the oxygen concentration in the VACB dropped below\nthe set-point of the oxygen sensors. This was due to both equipment malfunction and filling of the\nliquid nitrogen tank. All events occurred during off hours. The drop in oxygen concentration is\nnot compatible with human life. While biorepository staff are well trained to handle this event,\nfirst responders such as police or engineering staff who respond to the low oxygen alarm may\nenter the Biorepository without realizing the consequences.\n5. Performance Period: Four months. No options.\n6. Type of Contract: Firm-fixed price Service contract\n7. Place of Performance: Service performed at VA Boston Healthcare System, 150 S. Huntington\nAvenue, Jamaica Plain, MA 02130. Room RB-8\n8. General Requirements:\nAfter several discussions the Biorepository and the local engineering service decided to go with\npneumatic valves. The pressure required to operate these pneumatically controlled valves will be\nenabled with two nitrogen gas cylinders which will be placed near the liquid nitrogen tank. These\nnitrogen gas cylinders should be protected from external elements and secured properly by the\nvendor. In addition, the vendor shall provide an emergency inlet port that will supply liquid\nnitrogen to the nitrostore and the cryotank farm when the system is down for maintenance. In\naddition, we would require the vendor to provide all engineering services, documentation\ndeliverables, instrument installation and configuration, required electrical and mechanical\ninstallation, project management at site and internally, validation of the system, necessary\ntraining and a one year system warranty that includes parts and labor for the system. The figure\nbelow shows how the two valves are controlled by the two N2 cylinders. We will not use LN2\nsupply pressure to activate these valves.\n\n9. Requested Enhancements\nControl System Scope of Supply\na. One (1) Main O2 Monitoring & LN2 Isolation Control Panel\nb. Two (2) Local O2 Monitoring Control Panels [for redundant O2 monitors]\nc. Three (3) MSA TG5000 O2 Monitors with remote sensor kits\nd. Three (3) MSA Toxguard II remote sensor kits\ne. Four (4) NEMA 4 Lighted E-Stop Pushbutton Stations\nf. Two (2) LN2 Electronic Pressure Transmitters with manifold ranged 0 - 60 PSIG\ng. One (1) N2 Electronic Pressure Transmitter with manifold ranged 0 - 3,000 PSIG\nh. One (1) custom engineered LN2 valve manifold with the following features:\no All piping vacuum insulated for LN2 service\no Dual LN2 isolation valves, spring fail-closed pneumatic operator, 24VDC solenoids, DPDT Open\n& Close Limit switches and manual override capability\no Pressure relief valves in all pipe sections downstream of valves\no Emergency supply ports for the Nitrostore and Cryotank LN2 supply piping\no Taps for LN2 tank supply and building LN2 delivery pressure transmitters\ni. N2 tank control and monitoring system with the following features:\no Parker Gas Change-Over System unit that allows depressurizing and swapping tanks without\nloss of N2 pressure/flow. When one is empty the unit will automatically start drawing from the\nsecond tank.\no Low pressure switches for each tank s inlet connection\no Outdoor weather-shielded lockable cage with room for six (6) tanks total\no Two (2) 300CF series replaceable tanks of N2\nEngineering Services\nj. Design and Drafting of Local O2 Monitoring Panel\nk. Design and Drafting of Main O2 Monitoring & LN2 Isolation Panel\nl. Programming of PLC controller and HMI Monitoring Screens\nm. Design and drafting of custom LN2 valve manifold and associated site piping\nn. Design and drafting of N2 tank monitoring and control system\no. Design coordination with AEM and Rees Scientific\np. Factory Acceptance Test (FAT)\nq. Site commissioning, testing and system validation\nDocumentation Deliverables\nr. Control panel drawings and equipment data sheets\ns. Control system overview drawings\nt. LN2 valve manifold piping and instrumentation drawing (P&ID)\nu. N2 Tank control and monitoring system\nv. O2 monitoring and LN2 isolation system validation test plan\nInstrumentation Installation and Configuration\nw. Install and configure the following equipment and instruments:\no MSA TG5000 O2 monitors and remote sensor kits\no Remote O2 sensor kits for existing Toxguard IIs\no LN2 supply and delivery pressure transmitters\no N2 gas tank A pressure transmitter\no N2 gas tank pressure switches\nx. Configure the existing MSA Toxguard IIs and rewire the 115VAC power to be from the UPS in the Main\nO2 Monitoring and LN2 Isolation Panel.\nElectrical Installation\ny. Installation of NECI local and main control panels, remote E-stop stations, and O2 monitors\nz. Installation of O2 sensor extension kits on existing Toxguard II O2 monitors\naa. Supply, installation and wiring termination of all control cables, and power cables shown on the System\nOverview drawing.\nbb. Power and signal wiring to the AEP and REES Scientific panels.\ncc. Supply, installation and wiring termination of control cables to existing alarm sirens and strobe lights\nMechanical Installation\ndd. Installation of LN2 pressure transmitters and N2 pressure transmitter, transmitter sunshade and\nassociated impulse tubing.\nee. Installation of the custom outdoor LN2 valve and instrumentation manifold assembly\nff. Moving of the Cryotank Room LN2 piping take-off to be downstream of the isolation valves.\ngg. Addition of on-pad and off-pad pipe supports including foundations as required.\nhh. Supply and install N2 tank enclosure, N2 gas tank Changeover System and associated piping.\nInternal and On-Site Project Management\nii. Internal project management for detailed system design, parts procurement and regular updates to the\nVA.\njj. Management of electrical, LN2 piping and third-party suppliers (LN2 Manifold Supplier, AEM, Rees\nScientific)\nkk. One-site construction and installation management\nSystem Warranty\nll. Include a one-year parts and labor warranty for the system.","html":"This is a Sources Sought notice only. This is not a request for quotes and no contract will be awarded from this announcement. The Government will not provide any reimbursement for responses submitted in response to this Source Sought notice. Respondents will not be notified of the results of the evaluation. \nIf a solicitation is issued it shall be announced at a later date, and all interest parties must response to that solicitation announcement separately. Responses to this notice are not a request to be added to a prospective bidders list or to receive a copy of the solicitation\nThe purpose of this announcement is to perform market research to gain knowledge of potential qualified sources and their size classification relative to NAICS 541330, (K099) with a size standard $25.5 million. The Department of Veterans Affairs (VA), Network Contracting Office 1 (NCO 1) is seeking to identify any vendor capable of providing Liquid Nitrogen Safety Upgrades per the Statement of WorkÂ below. \nThis Sources Sought notice provides an opportunity for respondents to submit their capability and availability to provide the requirement described below. Vendors are encouraged to submit information relative to their capabilities to fulfill this requirement, in the form of a statement that addresses the specific requirement identified in this Sources Sought. Information received from this Sources Sought shall be utilized to facilitate the Contracting Officer s review of the market base, for acquisition planning, size determination, and procurement strategy.\nSubmission Instructions: Interested parties who consider themselves qualified to perform the services are invited to submit a response to this Sources Sought Notice by 12PM EST, November 20, 2025. All responses under this Sources Sought Notice must be emailed to issa.shawki@va.gov with Sources Sought #36C24126Q0086 in the subject line. Telephone inquiries will not be accepted or acknowledged, and no feedback or evaluations will be provided to companies regarding their submissions.\nInterested parties should complete the attached Sources Sought Worksheet. Parties may submit additional information related to their capabilities, provided it contains all the requirements contained in the Sources Sought Worksheet. Responses to this Sources Sought shall not exceed 8 pages. In addition, all submissions should be provided electronically in a Microsoft Word or Adobe PDF format.\nAttachment 1\nSources Sought Worksheet\nQUALIFICATION INFORMATION:\nCompany / Institute Name: _______________________________________________________\nAddress: ______________________________________________________________________\nPhone Number: ________________________________________________________________\nPoint of Contact: _______________________________________________________________\nE-mail Address: ________________________________________________________________\nUnique Entity Identifier (UEI) #:Â ___________________________________________________\nCAGE Code: __________________________________________________________________\nSAM Registered: (Y / N)\nOther available contract vehicles applicable to this sources sought (GSA/FSS/NASA SEWP/ETC): __________________________________________________________________\n______________________________________________________________________________\n______________________________________________________________________________\nSOCIO-ECONOMIC STATUS:\nVIP Verified SDVOSB: (Y / N)   \nVIP Verified VOSB: (Y / N)\n8(a): (Y / N)\nHUBZone: (Y / N)\nEconomically Disadvantaged Women-Owned Small Business: (Y / N)\nWomen-Owned Small Business: (Y / N)\nSmall Business: (Y / N)\nNOTE: Respondent claiming SDVOSB and VOSB status shall be registered and Center for Veterans Enterprise (CVE) verified in VetBiz Registry www.vetbiz.gov.\nBASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE/MARKET RESEARCH, THIS REQUIREMENT MAY BE SET-ASIDE FOR SDVOSB, VOSB, SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION.\nSTATEMENT OF WORK\nA. GENERAL INFORMATION\n1. Item: Enhancements to the VA Central Biorepository (VACB) liquid nitrogen system to provide\na fail-safe environment in case of a liquid nitrogen leak in the Building. The design of the\nenhanced liquid nitrogen (LN2) system must meet the following criteria:\na. Be simple to troubleshoot and easy to reestablish LN2 functionality within a period of\nless than an hour following a false positive event that led to a LN2 shutdown.\nb. The system must NOT be complex as to require an expert or extensive amount of time to\ntroubleshoot before functionality can be reestablished.\nc. System must be designed so that a lab personnel can operate with minimal training.\nd. System shall contain a fail-safe mechanism in the event of a liquid nitrogen leak.\n2. Purpose: The purpose of this contract is to provide certain enhancements necessary to provide a\nfail-safe environment in the VACB\n3. Scope of Work: The contractor shall provide all resources necessary to accomplish the\ndeliverables described in this performance work statement. The contractor should have expertise\nin cryogenics with positive past performance documented in the CPARS system. The Medical\nCenter requires the services of a qualified contractor which shall provide a fail-safe environment\nin case of a liquid nitrogen leak in the Building.\nThe VA Central Biorepository (VACB) stores millions of blood samples in a large robotic nitro\nstore, several cryogenic liquid nitrogen tanks and mechanical freezers. The cryogenic tanks and\nthe robotic nitrostore are supplied with liquid nitrogen from a large liquid nitrogen tank (11,000-\ngallon capacity) that is located outside the building at VABHS. The piping from this external\ntank to the nitrostore and cryogenic tanks was installed by Maccomber Cryogenics around 2011.\nCurrently there are several oxygen sensors located within the Biorepository that are tied into the\nalarm systems. When excess liquid nitrogen enters the laboratory the oxygen concentration in the\nroom can drop below levels necessary to sustain life. Currently, the only way to stop the flow of\nliquid nitrogen is to manually shut off the supply line at the liquid nitrogen tank. If the leak\nhappens during off hours this can take hours leading to an extremely dangerous situation,\nespecially for non-laboratory staff like police or engineering staff that might enter the room to\naddress the alarm. To mitigate risk to staff, under this contract the contractor shall:\nÂ· Add safety enhancements that would automatically cut-off the liquid nitrogen supply\nfrom the main external tank when the oxygen concentration drops below the\nrecommended set-point.\nÂ· Add 4 E-stop push button stations,\nÂ· Add three (3) additional oxygen sensors,\nÂ· Add emergency shutoff valves\nÂ· Add emergency inlet port for the nitrostore freezer and the cryotank farm room.\nÂ· All electrical signals emanating from the above mentioned instruments, including an\nexisting Tox Gard ii located in the nitrostore building, shall be connected to the main\noxygen monitoring and control panel and be integrated with the Biorepository s Alarm\nsystems as well as to the building s AEM alarm output system.\n4. Background: The VACB processes and stores specimens for clinical trials run by the VA\nCooperative Studies Program. The Biorepository is involved in a large-scale genomics project\nthat will require processing and storing of up to 1,000 samples a day in addition to existing and\nongoing processing for other Cooperative Studies Program projects. The Biorepository stores\nmillions of specimens donated by veterans for clinical research in a large robotic store known as\nthe nitrostore, cryogenic tanks and mechanical freezers. The nitrostore and cryogenic tanks are\ncooled with liquid nitrogen which is supplied from a large external liquid nitrogen tank located\noutside the building. Currently there are two shut off valves that are located near the external\nliquid nitrogen tank that would shut off the supply of liquid nitrogen to the nitrostore building and\nto the cryogenic tank room. The nitrostore requires a constant supply of liquid nitrogen, so a long\nshut off of the liquid nitrogen supply to the nitrostore would be detrimental to the stored\nspecimens. We can shut off liquid nitrogen supply to the cryotank room if all the cryotanks are\nfilled with appropriate amounts of liquid nitrogen. There have been several incidences of excess\nnitrogen releases in the laboratory where the oxygen concentration in the VACB dropped below\nthe set-point of the oxygen sensors. This was due to both equipment malfunction and filling of the\nliquid nitrogen tank. All events occurred during off hours. The drop in oxygen concentration is\nnot compatible with human life. While biorepository staff are well trained to handle this event,\nfirst responders such as police or engineering staff who respond to the low oxygen alarm may\nenter the Biorepository without realizing the consequences.\n5. Performance Period: Four months. No options.\n6. Type of Contract: Firm-fixed price Service contract\n7. Place of Performance: Service performed at VA Boston Healthcare System, 150 S. Huntington\nAvenue, Jamaica Plain, MA 02130. Room RB-8\n8. General Requirements:\nAfter several discussions the Biorepository and the local engineering service decided to go with\npneumatic valves. The pressure required to operate these pneumatically controlled valves will be\nenabled with two nitrogen gas cylinders which will be placed near the liquid nitrogen tank. These\nnitrogen gas cylinders should be protected from external elements and secured properly by the\nvendor. In addition, the vendor shall provide an emergency inlet port that will supply liquid\nnitrogen to the nitrostore and the cryotank farm when the system is down for maintenance. In\naddition, we would require the vendor to provide all engineering services, documentation\ndeliverables, instrument installation and configuration, required electrical and mechanical\ninstallation, project management at site and internally, validation of the system, necessary\ntraining and a one year system warranty that includes parts and labor for the system. The figure\nbelow shows how the two valves are controlled by the two N2 cylinders. We will not use LN2\nsupply pressure to activate these valves.\n\n9. Requested Enhancements\nControl System Scope of Supply\na. One (1) Main O2 Monitoring & LN2 Isolation Control Panel\nb. Two (2) Local O2 Monitoring Control Panels [for redundant O2 monitors]\nc. Three (3) MSA TG5000 O2 Monitors with remote sensor kits\nd. Three (3) MSA Toxguard II remote sensor kits\ne. Four (4) NEMA 4 Lighted E-Stop Pushbutton Stations\nf. Two (2) LN2 Electronic Pressure Transmitters with manifold ranged 0 - 60 PSIG\ng. One (1) N2 Electronic Pressure Transmitter with manifold ranged 0 - 3,000 PSIG\nh. One (1) custom engineered LN2 valve manifold with the following features:\no All piping vacuum insulated for LN2 service\no Dual LN2 isolation valves, spring fail-closed pneumatic operator, 24VDC solenoids, DPDT Open\n& Close Limit switches and manual override capability\no Pressure relief valves in all pipe sections downstream of valves\no Emergency supply ports for the Nitrostore and Cryotank LN2 supply piping\no Taps for LN2 tank supply and building LN2 delivery pressure transmitters\ni. N2 tank control and monitoring system with the following features:\no Parker Gas Change-Over System unit that allows depressurizing and swapping tanks without\nloss of N2 pressure/flow. When one is empty the unit will automatically start drawing from the\nsecond tank.\no Low pressure switches for each tank s inlet connection\no Outdoor weather-shielded lockable cage with room for six (6) tanks total\no Two (2) 300CF series replaceable tanks of N2\nEngineering Services\nj. Design and Drafting of Local O2 Monitoring Panel\nk. Design and Drafting of Main O2 Monitoring & LN2 Isolation Panel\nl. Programming of PLC controller and HMI Monitoring Screens\nm. Design and drafting of custom LN2 valve manifold and associated site piping\nn. Design and drafting of N2 tank monitoring and control system\no. Design coordination with AEM and Rees Scientific\np. Factory Acceptance Test (FAT)\nq. Site commissioning, testing and system validation\nDocumentation Deliverables\nr. Control panel drawings and equipment data sheets\ns. Control system overview drawings\nt. LN2 valve manifold piping and instrumentation drawing (P&ID)\nu. N2 Tank control and monitoring system\nv. O2 monitoring and LN2 isolation system validation test plan\nInstrumentation Installation and Configuration\nw. Install and configure the following equipment and instruments:\no MSA TG5000 O2 monitors and remote sensor kits\no Remote O2 sensor kits for existing Toxguard IIs\no LN2 supply and delivery pressure transmitters\no N2 gas tank A pressure transmitter\no N2 gas tank pressure switches\nx. Configure the existing MSA Toxguard IIs and rewire the 115VAC power to be from the UPS in the Main\nO2 Monitoring and LN2 Isolation Panel.\nElectrical Installation\ny. Installation of NECI local and main control panels, remote E-stop stations, and O2 monitors\nz. Installation of O2 sensor extension kits on existing Toxguard II O2 monitors\naa. Supply, installation and wiring termination of all control cables, and power cables shown on the System\nOverview drawing.\nbb. Power and signal wiring to the AEP and REES Scientific panels.\ncc. Supply, installation and wiring termination of control cables to existing alarm sirens and strobe lights\nMechanical Installation\ndd. Installation of LN2 pressure transmitters and N2 pressure transmitter, transmitter sunshade and\nassociated impulse tubing.\nee. Installation of the custom outdoor LN2 valve and instrumentation manifold assembly\nff. Moving of the Cryotank Room LN2 piping take-off to be downstream of the isolation valves.\ngg. Addition of on-pad and off-pad pipe supports including foundations as required.\nhh. Supply and install N2 tank enclosure, N2 gas tank Changeover System and associated piping.\nInternal and On-Site Project Management\nii. Internal project management for detailed system design, parts procurement and regular updates to the\nVA.\njj. Management of electrical, LN2 piping and third-party suppliers (LN2 Manifold Supplier, AEM, Rees\nScientific)\nkk. One-site construction and installation management\nSystem Warranty\nll. Include a one-year parts and labor warranty for the system.","origin":"detail"},"contacts":[{"name":"Issa Shawki","role":"primary","email":"issa.shawki@va.gov","phone":"774-826-3192","title":"Contracting Officer"}],"place_of_performance":{"zip":"02130","city":{"name":"Boston"},"state":{"name":"MA"},"country":{"code":"USA","name":"UNITED STATES"},"street2":"150 S. Huntington Avenue"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"naics_codes":["541330"],"award":{"awardee":{}},"attachments":[{"resource_id":"f8606501ffe44396820abd8b4b556940","name":"36C24126Q0086.docx","kind":"file","mime_type":".docx","size_bytes":702802,"posted_at":"2025-11-17T15:51:04.254Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f8606501ffe44396820abd8b4b556940/download","mirrored":false}],"awards":[],"related":[{"key":"36C24127Q0084","latest_notice_id":"939b8f3021be4a75ae5972b0c7ffb9ae","title":"X1EA--CWM VA Police Use of shooting range.","solicitation_number":"36C24127Q0084","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"611699","psc":"X1EA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24127Q0017","latest_notice_id":"d60676ea33af4051b90a1953ab55743e","title":"S201--36C24127Q0017 Windows Washing Service Amendment 0002","solicitation_number":"36C24127Q0017","notice_type":"k","first_type":"k","first_posted":"2026-10-26","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"561720","psc":"S201","set_aside":"SDVOSBC","state":"MA","county":"25017","county_name":"Middlesex County","city":"2501704615","city_name":"Bedford","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24127Q0044","latest_notice_id":"a2f2fe28c1ec4687b2a2955cf947935e","title":"9140--Togus Fuel Oil and Diesel Delivery","solicitation_number":"36C24127Q0044","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"324110","psc":"9140","set_aside":"SBA","state":"ME","county":"23011","county_name":"Kennebec County","city":"2302100","city_name":"Augusta","country":"USA","place_scope":"nationwide","state_source":"sam_zip","state_evidence":"04330","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24127Q0076","latest_notice_id":"bb30bc78067840a082b5d9e12eceddd2","title":"Q601--Sources sought Boston Medical Coding Period of Period 01/01/2027-04/01/2027","solicitation_number":"36C24127Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541219","psc":"Q601","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24127Q0030","latest_notice_id":"10c3d2d3d0c543179707f8cc9448f701","title":"J061--Eaton Powerware System Replacement","solicitation_number":"36C24127Q0030","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J061","set_aside":"SDVOSBC","state":"NH","county":"33011","county_name":"Hillsborough County","city":"3345140","city_name":"Manchester","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"FA222627R0003","latest_notice_id":"430df9e5b89541b99ca6b0bbc189b912","title":"C3BM ASE STRIKE Support","solicitation_number":"FA222627R0003","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-17","notices":3,"due_at":"2026-12-16T21:00:00Z","due_date":"2026-12-16","closes_at":"2026-12-16T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA2226","office_name":"FA2226 DAF PEO C3BM ASE CON","naics":"541330","psc":"R425","set_aside":null,"state":"MA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":"site","state_evidence":"AIR FORCE ORGANIZATION LOCATED AT HANSCOM AIR FORCE BASE","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"N6247027R0009","latest_notice_id":"676b5909f116428098423e63e57e16c8","title":"IDIQ Contract for Architect-Engineer (A-E) Services for Ship Homeporting and Related Operational Issues for Various Locations Throughout the Naval Facilities Engineering Systems Command Atlantic Area of Responsibility and Worldwide","solicitation_number":"N62470-27-R-0009","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62470","office_name":"NAVFACSYSCOM ATLANTIC","naics":"541330","psc":"C219","set_aside":null,"state":"VA","county":"51710","county_name":"City of Norfolk","city":"5157000","city_name":"Norfolk","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"SEAPORTNMRILFMSLABSPPTREV1","latest_notice_id":"4423bab4da4a4647be47503ffb97e48f","title":"SEAPORT_NMRIL_FMS_LAB_SPPT_1","solicitation_number":"SEAPORT_NMRIL_FMS_LAB_SPPT_REV1","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N66001","office_name":"NIWC PACIFIC","naics":"541330","psc":"R425","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"}],"similar_open_total":98,"indexable":false}