{"canonical":"https://sealedbidder.com/opportunities/36c24125r0058","key":"36C24125R0058","url":"https://sealedbidder.com/opportunities/36c24125r0058","title":"C1DA--402-25-008 Repair Condensate Pump Room Roof","solicitation_number":"36C24125R0058","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-11T21:30:00Z","first_posted":"2025-01-27","last_posted":"2025-05-27","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541330","psc":"C1DA","set_aside":null,"place_state":"ME","place_scope":"site","site":null,"place_state_source":"sam_zip","place_evidence":null,"place_county":"23011","place_county_name":"Kennebec County","place_city":null,"place_city_name":null,"winner":"HARRIMAN ASSOCIATES","award_amount":null,"publications":[{"notice_id":"99c2dfda833c49559ebcafe0ad6785b7","title":"C1DA--A-E Repair Condensate Pump Room Roof, 402-25-008","solicitation_number":"36C24125R0058","notice_type":"r","base_type":"r","posted":"2025-01-27","posted_at":"2025-01-27T14:26:48.682Z","due_at":"2025-02-11T21:30:00Z","due_date":"2025-02-11","cancelled":false,"archived":true,"archive_date":"2025-04-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/99c2dfda833c49559ebcafe0ad6785b7/view","enriched":true,"history":[{"index":3,"title":"C1DA--A-E Repair Condensate Pump Room Roof, 402-25-008","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-27T14:26:48.682Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"99c2dfda833c49559ebcafe0ad6785b7","solicitation_number":"36C24125R0058"}]},{"notice_id":"a69ce57fbe12484781c5dc1a4688421e","title":"C1DA--402-25-008 Repair Condensate Pump Room Roof","solicitation_number":"36C24125R0058","notice_type":"s","base_type":"s","posted":"2025-05-27","posted_at":"2025-05-27T18:46:17.109Z","due_at":"2025-06-27T20:30:00Z","due_date":"2025-06-27","cancelled":false,"archived":true,"archive_date":"2025-09-25","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a69ce57fbe12484781c5dc1a4688421e/view","enriched":true,"history":[{"index":3,"title":"C1DA--402-25-008 Repair Condensate Pump Room Roof","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-27T18:46:17.109Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"a69ce57fbe12484781c5dc1a4688421e","solicitation_number":"36C24125R0058"}]}],"latest_notice_id":"a69ce57fbe12484781c5dc1a4688421e","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-01-27","posted_at":"2025-01-27T14:26:48.682Z","created_at":"2025-01-27T14:26:46.269Z","modified_at":"2025-04-12T04:04:32.318Z","response_deadline":{"raw":"2025-02-11T16:30:00-05:00","utc":"2025-02-11T21:30:00Z","date":"2025-02-11","time":"16:30:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/99c2dfda833c49559ebcafe0ad6785b7/view"},"naics":{"codes":["541330"],"primary":"541330"},"title":"C1DA--A-E Repair Condensate Pump Room Roof, 402-25-008","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-12","archive_type":"auto_custom"},"history":[{"index":3,"title":"C1DA--A-E Repair Condensate Pump Room Roof, 402-25-008","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-27T14:26:48.682Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"99c2dfda833c49559ebcafe0ad6785b7","solicitation_number":"36C24125R0058"}],"contacts":[{"name":"Andrew Merical","role":"primary","email":"Andrew.Merical@va.gov","phone":"Email Only","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"99c2dfda833c49559ebcafe0ad6785b7","lineage_id":"99c2dfda833c49559ebcafe0ad6785b7","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T08:24:06.106574477Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"cc43010183a98f7f0c1e310fef69263531fe3b527ef8856ed21e828b17618f63","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T08:24:06.106574477Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought\nThe Togus Veterans Affairs Medical Center (VAMC) in accordance with the Veterans Affairs Maine Healthcare System has a requirement for a Firm-Fixed-Price contract to provide professional Architect and Engineering (A/E) Design Services to develop complete drawings, specifications, cost estimates, construction period administration services, and site visits associated with the following objectives:\nThe Government is in need of repairing a deteriorating Condensate Pump Room Roof in the basement of Building 201.\nThis design must consider the need for all condensate pumps to remain in operation during the construction period.\nThis requirement consists of concrete testing and design for temporary shoring, abatement (if necessary), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant.\nThe design must include detailed plans on how to support all existing utilities currently within the ceiling which include multiple pipes, electrical conduits, lights, etc.\nThe North American Industry Classification System (NAICS) code is 541330 and the small business standard is $25.5 million. Any interested Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), and Small Business (SB) must indicate interest for this project, in writing, to the Contracting Specialist NO LATER THAN FEBRUARY 11, 2025, AT 4:30 PM EST via e-mail to Andrew.Merical@va.gov. \nTo qualify as interested in this project, information pertaining to the following six (6) components must be submitted in response to this notice on or before February 11, 2025, at 4:30 pm EST:\nStatement of intent that a proposal will be submitted to the solicitation for this project, which said Statement of Intent shall include the company s System for Award Management Unique Entity Identifier (SAM UEI) Number;\nVerification through VetCert and/or the Small Business Administration (SBA) Veteran Small Business Certification (VetCert) as an SDVOSB or VOSB under the NAICS Code 541330, if applicable;\nEvidence of A/E experience with projects primarily located within a medical facility setting, with a construction magnitude of $250,000.00 or more. (Please provide contract descriptions, contract dollar amounts, and telephone numbers for points of contact   no photographs);\nEvidence of A/E experience developing a phasing plan focused on minimizing demolition and construction impacts to the medical facility;\nEvidence of the company s ability to perform at least fifty percent (50%) of this requirement in accordance with FAR 52.219-14: Limitations on Subcontracting; and\nProof of professional liability insurance required to cover the monetary amount of this project.\nAll six (6) components must be submitted, in sufficient detail, prior to the designated deadline for a determination on available and interested SDVOSBs, VOSBs, and SBs. Failure to submit each of the six (6) components, as identified above, will result in a Contractor not being considered as an interested SDVOSB, VOSB, or SB.\nIf adequate interest is not received to this notice by SDVOSBs, VOSBs, and/or SBs, then this project will not be set-aside. As indicated above, interested businesses may reply to this notice via e-mail to Andrew.Merical@va.gov.\nBusinesses must be registered in the System for Award Management (SAM). To register in the SAM database, visit www.sam.gov. SDVOSBs or VOSBs must also be verified by the center for Veteran Enterprise (CVE).\nPlease note that all attachments listed within the SOW will be made available for viewing during the Solicitation period.\nThis Sources Sought Notice was prepared and considered in accordance with FAR 5.203, FAR 5.204, and FAR 5.207, information for future acquisitions.\nDISCLAIMER: This Source Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this notice is marked as proprietary and will be handled accordingly. In accordance with FAR 15.201(e), responses to this Notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this notice.","text":"Sources Sought\nThe Togus Veterans Affairs Medical Center (VAMC) in accordance with the Veterans Affairs Maine Healthcare System has a requirement for a Firm-Fixed-Price contract to provide professional Architect and Engineering (A/E) Design Services to develop complete drawings, specifications, cost estimates, construction period administration services, and site visits associated with the following objectives:\nThe Government is in need of repairing a deteriorating Condensate Pump Room Roof in the basement of Building 201.\nThis design must consider the need for all condensate pumps to remain in operation during the construction period.\nThis requirement consists of concrete testing and design for temporary shoring, abatement (if necessary), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant.\nThe design must include detailed plans on how to support all existing utilities currently within the ceiling which include multiple pipes, electrical conduits, lights, etc.\nThe North American Industry Classification System (NAICS) code is 541330 and the small business standard is $25.5 million. Any interested Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), and Small Business (SB) must indicate interest for this project, in writing, to the Contracting Specialist NO LATER THAN FEBRUARY 11, 2025, AT 4:30 PM EST via e-mail to Andrew.Merical@va.gov.\nTo qualify as interested in this project, information pertaining to the following six (6) components must be submitted in response to this notice on or before February 11, 2025, at 4:30 pm EST:\nStatement of intent that a proposal will be submitted to the solicitation for this project, which said Statement of Intent shall include the company s System for Award Management Unique Entity Identifier (SAM UEI) Number;\nVerification through VetCert and/or the Small Business Administration (SBA) Veteran Small Business Certification (VetCert) as an SDVOSB or VOSB under the NAICS Code 541330, if applicable;\nEvidence of A/E experience with projects primarily located within a medical facility setting, with a construction magnitude of $250,000.00 or more. (Please provide contract descriptions, contract dollar amounts, and telephone numbers for points of contact no photographs);\nEvidence of A/E experience developing a phasing plan focused on minimizing demolition and construction impacts to the medical facility;\nEvidence of the company s ability to perform at least fifty percent (50%) of this requirement in accordance with FAR 52.219-14: Limitations on Subcontracting; and\nProof of professional liability insurance required to cover the monetary amount of this project.\nAll six (6) components must be submitted, in sufficient detail, prior to the designated deadline for a determination on available and interested SDVOSBs, VOSBs, and SBs. Failure to submit each of the six (6) components, as identified above, will result in a Contractor not being considered as an interested SDVOSB, VOSB, or SB.\nIf adequate interest is not received to this notice by SDVOSBs, VOSBs, and/or SBs, then this project will not be set-aside. As indicated above, interested businesses may reply to this notice via e-mail to Andrew.Merical@va.gov.\nBusinesses must be registered in the System for Award Management (SAM). To register in the SAM database, visit www.sam.gov. SDVOSBs or VOSBs must also be verified by the center for Veteran Enterprise (CVE).\nPlease note that all attachments listed within the SOW will be made available for viewing during the Solicitation period.\nThis Sources Sought Notice was prepared and considered in accordance with FAR 5.203, FAR 5.204, and FAR 5.207, information for future acquisitions.\nDISCLAIMER: This Source Sought Notice is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this notice is marked as proprietary and will be handled accordingly. In accordance with FAR 15.201(e), responses to this Notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this notice.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C24125R0058","place_of_performance":{"zip":"04330","city":{"name":"Augusta, ME"},"street":"VAMC Togus 1 VA Center","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"C1DA"},{"award":{"awardee":{}},"dates":{"posted":"2025-05-27","posted_at":"2025-05-27T18:46:17.109Z","created_at":"2025-05-27T18:45:49.946Z","modified_at":"2025-09-26T03:55:56.030Z","response_deadline":{"raw":"2025-06-27T16:30:00-04:00","utc":"2025-06-27T20:30:00Z","date":"2025-06-27","time":"16:30:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a69ce57fbe12484781c5dc1a4688421e/view"},"naics":{"codes":["541330"],"primary":"541330"},"title":"C1DA--402-25-008 Repair Condensate Pump Room Roof","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-25","archive_type":"auto_custom"},"history":[{"index":3,"title":"C1DA--402-25-008 Repair Condensate Pump Room Roof","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-27T18:46:17.109Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"a69ce57fbe12484781c5dc1a4688421e","solicitation_number":"36C24125R0058"}],"contacts":[{"name":"Andrew Merical","role":"primary","email":"Andrew.Merical@va.gov","phone":"401-273-7100","title":"Contract Specialist"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"a69ce57fbe12484781c5dc1a4688421e","lineage_id":"a69ce57fbe12484781c5dc1a4688421e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-14T01:03:25.465449103Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"00e8f307baf6fa93a31da37ea355dbd38966c4c0d51522b5b79284e24da7a58a","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-14T01:03:25.465449103Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Request For Qualifications Statements (SF 330)\nGeneral Project Description:\nProject Number: 402-25-008\nProject Title: A-E Repair Condensate Pump Room Roof\nLocation of Project: VA Maine Healthcare System (VAMC Togus), Augusta, Maine 04330\nA/E Type A&B Services (also known as Design Phase) for this design project includes site visits, field investigation, studies and user interviews to prepare drawings, specifications and cost estimates for all facets of work and disciplines/trades to repair condensate pump room roof located on the Togus campus. This project will repair the deteriorating condensate pump room roof in the basement of B201. The A/E must consider the need for all condensate pumps to remain operational during the construction period. This project will consist of concrete testing and design for temporary shoring, abatement (if required), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant. The existing ceiling supports multiple pipes and electrical conduits, lights, etc. The design package should include detailed plans on how to temporarily support all existing utilities. If disconnection is required, the A/E must determine the source of energy, existing isolation locations, and impact to facility when isolated. The A/E is to provide a final load rating for the roof once repairs are complete. The design will include drawings showing ICRA required construction barriers, properly sized negative air machines, as well as duct routing for exhausting air. Additionally, the A/E shall prepare all required National Environmental Policy Act (NEPA) analysis and Environmental Assessment reports and documentation for any improvements made as part of this project.\n\nNAICS and Set-Aside Information: \nThis procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has an SBA size standard of $25.5 million in average revenue. This procurement is a total set-aside for verified Small Businesses (SB).\nKey Dates:\nPeriod of Performance: 120 calendar days.\nQuestions Due: 06/06/2025 4:30 PM EST.\nSF 330 Package Due: 06/27/2025 4:30 PM EST.\nInstructions:\nSee attached Request for Qualification Statement (SF330s) for submission requirements.","text":"Request For Qualifications Statements (SF 330)\nGeneral Project Description:\nProject Number: 402-25-008\nProject Title: A-E Repair Condensate Pump Room Roof\nLocation of Project: VA Maine Healthcare System (VAMC Togus), Augusta, Maine 04330\nA/E Type A&B Services (also known as Design Phase) for this design project includes site visits, field investigation, studies and user interviews to prepare drawings, specifications and cost estimates for all facets of work and disciplines/trades to repair condensate pump room roof located on the Togus campus. This project will repair the deteriorating condensate pump room roof in the basement of B201. The A/E must consider the need for all condensate pumps to remain operational during the construction period. This project will consist of concrete testing and design for temporary shoring, abatement (if required), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant. The existing ceiling supports multiple pipes and electrical conduits, lights, etc. The design package should include detailed plans on how to temporarily support all existing utilities. If disconnection is required, the A/E must determine the source of energy, existing isolation locations, and impact to facility when isolated. The A/E is to provide a final load rating for the roof once repairs are complete. The design will include drawings showing ICRA required construction barriers, properly sized negative air machines, as well as duct routing for exhausting air. Additionally, the A/E shall prepare all required National Environmental Policy Act (NEPA) analysis and Environmental Assessment reports and documentation for any improvements made as part of this project.\n\nNAICS and Set-Aside Information:\nThis procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has an SBA size standard of $25.5 million in average revenue. This procurement is a total set-aside for verified Small Businesses (SB).\nKey Dates:\nPeriod of Performance: 120 calendar days.\nQuestions Due: 06/06/2025 4:30 PM EST.\nSF 330 Package Due: 06/27/2025 4:30 PM EST.\nInstructions:\nSee attached Request for Qualification Statement (SF330s) for submission requirements.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24125R0058","product_service_code":"C1DA"}],"due_at":"2025-02-11T21:30:00Z","due_date":"2025-02-11","closes_at":"2025-02-11T21:30:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","state":"ME","county":"23011","county_name":"Kennebec County","city":null,"city_name":null,"country":"USA","state_source":"sam_zip","state_evidence":null,"site_key":null,"winner_key":"SFEFWZKEB7L7","amount":null,"linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-11-14T01:15:55.955263Z","principal_notice_id":"a69ce57fbe12484781c5dc1a4688421e","description":{"text":"Request For Qualifications Statements (SF 330)\nGeneral Project Description:\nProject Number: 402-25-008\nProject Title: A-E Repair Condensate Pump Room Roof\nLocation of Project: VA Maine Healthcare System (VAMC Togus), Augusta, Maine 04330\nA/E Type A&B Services (also known as Design Phase) for this design project includes site visits, field investigation, studies and user interviews to prepare drawings, specifications and cost estimates for all facets of work and disciplines/trades to repair condensate pump room roof located on the Togus campus. This project will repair the deteriorating condensate pump room roof in the basement of B201. The A/E must consider the need for all condensate pumps to remain operational during the construction period. This project will consist of concrete testing and design for temporary shoring, abatement (if required), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant. The existing ceiling supports multiple pipes and electrical conduits, lights, etc. The design package should include detailed plans on how to temporarily support all existing utilities. If disconnection is required, the A/E must determine the source of energy, existing isolation locations, and impact to facility when isolated. The A/E is to provide a final load rating for the roof once repairs are complete. The design will include drawings showing ICRA required construction barriers, properly sized negative air machines, as well as duct routing for exhausting air. Additionally, the A/E shall prepare all required National Environmental Policy Act (NEPA) analysis and Environmental Assessment reports and documentation for any improvements made as part of this project.\n\nNAICS and Set-Aside Information:\nThis procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has an SBA size standard of $25.5 million in average revenue. This procurement is a total set-aside for verified Small Businesses (SB).\nKey Dates:\nPeriod of Performance: 120 calendar days.\nQuestions Due: 06/06/2025 4:30 PM EST.\nSF 330 Package Due: 06/27/2025 4:30 PM EST.\nInstructions:\nSee attached Request for Qualification Statement (SF330s) for submission requirements.","html":"Request For Qualifications Statements (SF 330)\nGeneral Project Description:\nProject Number: 402-25-008\nProject Title: A-E Repair Condensate Pump Room Roof\nLocation of Project: VA Maine Healthcare System (VAMC Togus), Augusta, Maine 04330\nA/E Type A&B Services (also known as Design Phase) for this design project includes site visits, field investigation, studies and user interviews to prepare drawings, specifications and cost estimates for all facets of work and disciplines/trades to repair condensate pump room roof located on the Togus campus. This project will repair the deteriorating condensate pump room roof in the basement of B201. The A/E must consider the need for all condensate pumps to remain operational during the construction period. This project will consist of concrete testing and design for temporary shoring, abatement (if required), demolition of existing concrete and rebar, concrete forming, new concrete, and sealant. The existing ceiling supports multiple pipes and electrical conduits, lights, etc. The design package should include detailed plans on how to temporarily support all existing utilities. If disconnection is required, the A/E must determine the source of energy, existing isolation locations, and impact to facility when isolated. The A/E is to provide a final load rating for the roof once repairs are complete. The design will include drawings showing ICRA required construction barriers, properly sized negative air machines, as well as duct routing for exhausting air. Additionally, the A/E shall prepare all required National Environmental Policy Act (NEPA) analysis and Environmental Assessment reports and documentation for any improvements made as part of this project.\n\nNAICS and Set-Aside Information: \nThis procurement for Architect & Engineering services is assigned NAICS 541330 Engineering Services which has an SBA size standard of $25.5 million in average revenue. This procurement is a total set-aside for verified Small Businesses (SB).\nKey Dates:\nPeriod of Performance: 120 calendar days.\nQuestions Due: 06/06/2025 4:30 PM EST.\nSF 330 Package Due: 06/27/2025 4:30 PM EST.\nInstructions:\nSee attached Request for Qualification Statement (SF330s) for submission requirements.","origin":"detail"},"contacts":[{"name":"Andrew Merical","role":"primary","email":"Andrew.Merical@va.gov","phone":"401-273-7100","title":"Contract Specialist"}],"place_of_performance":null,"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"naics_codes":["541330"],"award":{"awardee":{}},"attachments":[{"resource_id":"12cd93a8ec7a4df18e9f89e195706e08","name":"36C24125R0058.docx","kind":"file","mime_type":".docx","size_bytes":26215,"posted_at":"2025-01-27T14:26:48.682Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/12cd93a8ec7a4df18e9f89e195706e08/download","mirrored":false},{"resource_id":"dc7cc9dc332442ad8a71ce0ed8f116ae","name":"36C24125R0058_1.docx","kind":"file","mime_type":".docx","size_bytes":24600,"posted_at":"2025-05-27T18:46:17.109Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dc7cc9dc332442ad8a71ce0ed8f116ae/download","mirrored":false},{"resource_id":"b6f405018f0b47218af0234a1363bdd8","name":"SOW Final.docx","kind":"file","mime_type":".docx","size_bytes":81897,"posted_at":"2025-01-27T14:26:48.682Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b6f405018f0b47218af0234a1363bdd8/download","mirrored":false},{"resource_id":"dcaf5c0e78334e458bb60bfb5103c4c4","name":"Special Notice Request for Qualifications SF330 - Repair Condensate Pump Room Roof.docx","kind":"file","mime_type":".docx","size_bytes":65024,"posted_at":"2025-05-27T18:46:17.109Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dcaf5c0e78334e458bb60bfb5103c4c4/download","mirrored":false},{"resource_id":"cfe82844648b4a458d140d5207e21824","name":"SOW Final.docx","kind":"file","mime_type":".docx","size_bytes":81547,"posted_at":"2025-05-27T18:46:17.109Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cfe82844648b4a458d140d5207e21824/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_36C24125C0083_3600_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_36C24125C0083_3600_-NONE-_-NONE-/","piid":"36C24125C0083","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"SFEFWZKEB7L7","recipient_name":"HARRIMAN ASSOCIATES","recipient_uei":"SFEFWZKEB7L7","recipient_cage":"0HW22","recipient_city":"AUBURN","recipient_state":"ME","sub_name":"Department of Veterans Affairs","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","office_key":"o-36C241","first_action_date":"2025-09-26","last_action_date":"2025-09-26","actions":1,"obligated":"72778.06","current_total_value":"72778.06","potential_total_value":"72778.06","naics":"541330","psc":"C1DA","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":1,"description":"A-E REPAIR CONDENSATE PUMP ROOM ROOF- TYPE A SERVICES","method":"solicitation","confidence":"high","evidence":["solicitation number 36C24125R0058 equals the FPDS solicitation identifier","same awarding office 36C241"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"36C24127Q0084","latest_notice_id":"939b8f3021be4a75ae5972b0c7ffb9ae","title":"X1EA--CWM VA Police Use of shooting range.","solicitation_number":"36C24127Q0084","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"611699","psc":"X1EA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24127Q0017","latest_notice_id":"d60676ea33af4051b90a1953ab55743e","title":"S201--36C24127Q0017 Windows Washing Service Amendment 0002","solicitation_number":"36C24127Q0017","notice_type":"k","first_type":"k","first_posted":"2026-10-26","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"561720","psc":"S201","set_aside":"SDVOSBC","state":"MA","county":"25017","county_name":"Middlesex County","city":"2501704615","city_name":"Bedford","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24127Q0044","latest_notice_id":"a2f2fe28c1ec4687b2a2955cf947935e","title":"9140--Togus Fuel Oil and Diesel Delivery","solicitation_number":"36C24127Q0044","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"324110","psc":"9140","set_aside":"SBA","state":"ME","county":"23011","county_name":"Kennebec County","city":"2302100","city_name":"Augusta","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24127Q0076","latest_notice_id":"bb30bc78067840a082b5d9e12eceddd2","title":"Q601--Sources sought Boston Medical Coding Period of Period 01/01/2027-04/01/2027","solicitation_number":"36C24127Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541219","psc":"Q601","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24127Q0030","latest_notice_id":"10c3d2d3d0c543179707f8cc9448f701","title":"J061--Eaton Powerware System Replacement","solicitation_number":"36C24127Q0030","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J061","set_aside":"SDVOSBC","state":"NH","county":"33011","county_name":"Hillsborough County","city":"3345140","city_name":"Manchester","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"N6247027R0009","latest_notice_id":"676b5909f116428098423e63e57e16c8","title":"IDIQ Contract for Architect-Engineer (A-E) Services for Ship Homeporting and Related Operational Issues for Various Locations Throughout the Naval Facilities Engineering Systems Command Atlantic Area of Responsibility and Worldwide","solicitation_number":"N62470-27-R-0009","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N62470","office_name":"NAVFACSYSCOM ATLANTIC","naics":"541330","psc":"C219","set_aside":null,"state":"VA","county":"51710","county_name":"City of Norfolk","city":"5157000","city_name":"Norfolk","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"SEAPORTNMRILFMSLABSPPTREV1","latest_notice_id":"4423bab4da4a4647be47503ffb97e48f","title":"SEAPORT_NMRIL_FMS_LAB_SPPT_1","solicitation_number":"SEAPORT_NMRIL_FMS_LAB_SPPT_REV1","notice_type":"r","first_type":"r","first_posted":"2026-11-16","last_posted":"2026-11-16","notices":1,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N66001","office_name":"NIWC PACIFIC","naics":"541330","psc":"R425","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-17T04:42:47.571825Z"},{"key":"36C24227Q0091","latest_notice_id":"5d73616203d447e888c36d0c3fdea423","title":"R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630","solicitation_number":"36C24227Q0091","notice_type":"k","first_type":"k","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"541330","psc":"R425","set_aside":"SDVOSBC","state":"NY","county":"36061","county_name":"New York County","city":"3651000","city_name":"New York","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"}],"similar_open_total":98,"indexable":false}