{"canonical":"https://sealedbidder.com/opportunities/36c24125q0376","key":"36C24125Q0376","url":"https://sealedbidder.com/opportunities/36c24125q0376","title":"J041--Chiller Maintenance","solicitation_number":"36C24125Q0376","notice_type":"s","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-11T16:00:00Z","first_posted":"2025-04-08","last_posted":"2025-04-08","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J041","set_aside":null,"place_state":null,"place_scope":"unknown","site":null,"place_state_source":null,"place_evidence":null,"place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"7b49668aebd748108a8a4c5bdfa69a01","title":"J041--Chiller Maintenance","solicitation_number":"36C24125Q0376","notice_type":"s","base_type":"s","posted":"2025-04-08","posted_at":"2025-04-08T20:00:08.051Z","due_at":"2025-04-11T16:00:00Z","due_date":"2025-04-11","cancelled":false,"archived":true,"archive_date":"2025-06-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7b49668aebd748108a8a4c5bdfa69a01/view","enriched":true,"history":[{"index":3,"title":"J041--Chiller Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-08T20:00:08.051Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"7b49668aebd748108a8a4c5bdfa69a01","solicitation_number":"36C24125Q0376"}]}],"latest_notice_id":"7b49668aebd748108a8a4c5bdfa69a01","first_type":"s","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-04-08","posted_at":"2025-04-08T20:00:08.051Z","created_at":"2025-04-08T20:00:05.857Z","modified_at":"2025-06-11T03:55:45.155Z","response_deadline":{"raw":"2025-04-11T12:00:00-04:00","utc":"2025-04-11T16:00:00Z","date":"2025-04-11","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7b49668aebd748108a8a4c5bdfa69a01/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"J041--Chiller Maintenance","agency":{"office":{"code":"36C241","name":"241-NETWORK CONTRACT OFFICE 01 (36C241)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"organization_id":"100176746","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"J041--Chiller Maintenance","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-08T20:00:08.051Z","notice_type":{"code":"s","label":"Special Notice"},"request_type":"submit","opportunity_id":"7b49668aebd748108a8a4c5bdfa69a01","solicitation_number":"36C24125Q0376"}],"contacts":[{"name":"Issa Shawki","role":"primary","email":"issa.shawki@va.gov","phone":"774-826-3192","title":"Contracting Officer"}],"base_type":{"code":"s","label":"Special Notice"},"notice_id":"7b49668aebd748108a8a4c5bdfa69a01","lineage_id":"7b49668aebd748108a8a4c5bdfa69a01","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-18T04:31:10.305100454Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"732a7e179478f74a5e68333fdab2d915f64ebf7df1e443793270dcce698aba47","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-18T04:31:10.305100454Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"The Department of Veteran Affairs, Networking Contracting Office (NCO1) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Johnson Controls for the following requirement:\nSTATEMENT OF WORK (SOW)\n1.0 Scope of Work\n\nThe contractor will perform chiller maintenance and inspections at the Boston Healthcare System, Brockton Division. Contractor is responsible for all labor, materials, tools and special equipment required to perform the work.\n\n2.0 Performance Requirements\n\nChiller, Water Cooled, Magnetic Bearing Centrifugal, 451-600 Tons\nOperational \nAll work must be performed in accordance with safety policies \nCheck with appropriate customer representative for operational deficiencies \nReview control panel for proper operation and recorded fault histories \nCheck for proper condenser and chilled water flow\nCheck system pressures and temperatures \nCheck refrigerant levels \nCheck capacity control and linkage Inspect for signs of refrigerant leakage \nCheck for unusual noise and vibration\nCheck overall condition of unit \nRecord and log all operating parameters For YK, YMC2, YZ, YD, YVAA, YMAA, and YS - Review the Proactive Parts Replacement Tool for components that may be in need of or recommended for proactive replacement. \nRun VSD Diagnostics \nDocument tasks performed during visit and report any observations to appropriate customer representative\nComprehensive \nAll work must be performed in accordance with safety policies \nCheck with appropriate customer representative for operational deficiencies \nReview control panel for proper operation and recorded fault histories \nConduct refrigerant leak check Lubricate and check capacity control and linkage \nCheck and tighten electrical connections \nPerform preventative procedures to flow proving devices \nPerform VSD coolant change procedures \nCheck for unusual noise and vibration \nCheck overall condition of unit For YK, YMC2, YZ, YD, YVAA, YMAA, and YS - Review the Proactive Parts Replacement Tool for components that may be in need of or recommended for proactive replacement. \nRun VSD Diagnostics Remove and dispose any debris from any maintenance activity \nDocument tasks performed during visit and report any observations to appropriate customer representative\nCondenser Tube Brushing (removal and replacement of one head only) \nAll work must be performed in accordance with safety policies \nCheck with appropriate customer representative for operational deficiencies \nIsolate tubes Drain water from tubes \nRemove head Mechanically brush tubes \nReplace gasket \nReplace head \nRemove and dispose any debris from any maintenance activity \nDocument tasks performed during visit and report any observations to appropriate customer representative\nEvaporator Tube Brushing (removal and replacement of one head only) \nAll work must be performed in accordance with safety policies \nCheck with appropriate customer representative for operational deficiencies Isolate tubes Drain water from tubes\nRemove head Mechanically brush tubes \nReplace gasket Replace head \nRemove and dispose any debris from any maintenance activity \nDocument tasks performed during visit and report any observations to appropriate customer representative\nRefrigerant Sample and Analysis\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies \nRemove sample in approved container \nDrop off for analysis \nLabel and complete paperwork indicating present operating conditions \nDocument tasks performed during visit and report any observations to appropriate customer representative\n3.0 Equipment List   \n\n\nJohnson Controls will be awarded this procurement because Johnson Controls (JCI) acquired YORK International in 2005 in which all YORK manufactured chillers are proprietary for integrated JCI controls and systems. JCI is the only contractor with the capability to perform the required services on the YORK controlled chillers.  The VA owned JCI system is a proprietary control system and will only have true full compatibility with other YORK/JCI components, software and personnel. Other contractors are unable to perform this work due to not having access to JCI software and replacement supplies. \n\nThe NAICS code for this requirement is 811310 with small business size standard of $12.5 Million.\nThis notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement listed above must clearly identify their capability to do so in writing by April 11, 2025 at 12 pm EST time. Responses should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination by the Government not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.","text":"The Department of Veteran Affairs, Networking Contracting Office (NCO1) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Johnson Controls for the following requirement:\nSTATEMENT OF WORK (SOW)\n1.0 Scope of Work\n\nThe contractor will perform chiller maintenance and inspections at the Boston Healthcare System, Brockton Division. Contractor is responsible for all labor, materials, tools and special equipment required to perform the work.\n\n2.0 Performance Requirements\n\nChiller, Water Cooled, Magnetic Bearing Centrifugal, 451-600 Tons\nOperational\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies\nReview control panel for proper operation and recorded fault histories\nCheck for proper condenser and chilled water flow\nCheck system pressures and temperatures\nCheck refrigerant levels\nCheck capacity control and linkage Inspect for signs of refrigerant leakage\nCheck for unusual noise and vibration\nCheck overall condition of unit\nRecord and log all operating parameters For YK, YMC2, YZ, YD, YVAA, YMAA, and YS - Review the Proactive Parts Replacement Tool for components that may be in need of or recommended for proactive replacement.\nRun VSD Diagnostics\nDocument tasks performed during visit and report any observations to appropriate customer representative\nComprehensive\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies\nReview control panel for proper operation and recorded fault histories\nConduct refrigerant leak check Lubricate and check capacity control and linkage\nCheck and tighten electrical connections\nPerform preventative procedures to flow proving devices\nPerform VSD coolant change procedures\nCheck for unusual noise and vibration\nCheck overall condition of unit For YK, YMC2, YZ, YD, YVAA, YMAA, and YS - Review the Proactive Parts Replacement Tool for components that may be in need of or recommended for proactive replacement.\nRun VSD Diagnostics Remove and dispose any debris from any maintenance activity\nDocument tasks performed during visit and report any observations to appropriate customer representative\nCondenser Tube Brushing (removal and replacement of one head only)\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies\nIsolate tubes Drain water from tubes\nRemove head Mechanically brush tubes\nReplace gasket\nReplace head\nRemove and dispose any debris from any maintenance activity\nDocument tasks performed during visit and report any observations to appropriate customer representative\nEvaporator Tube Brushing (removal and replacement of one head only)\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies Isolate tubes Drain water from tubes\nRemove head Mechanically brush tubes\nReplace gasket Replace head\nRemove and dispose any debris from any maintenance activity\nDocument tasks performed during visit and report any observations to appropriate customer representative\nRefrigerant Sample and Analysis\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies\nRemove sample in approved container\nDrop off for analysis\nLabel and complete paperwork indicating present operating conditions\nDocument tasks performed during visit and report any observations to appropriate customer representative\n3.0 Equipment List\n\nJohnson Controls will be awarded this procurement because Johnson Controls (JCI) acquired YORK International in 2005 in which all YORK manufactured chillers are proprietary for integrated JCI controls and systems. JCI is the only contractor with the capability to perform the required services on the YORK controlled chillers. The VA owned JCI system is a proprietary control system and will only have true full compatibility with other YORK/JCI components, software and personnel. Other contractors are unable to perform this work due to not having access to JCI software and replacement supplies.\n\nThe NAICS code for this requirement is 811310 with small business size standard of $12.5 Million.\nThis notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement listed above must clearly identify their capability to do so in writing by April 11, 2025 at 12 pm EST time. Responses should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination by the Government not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.","origin":"detail"},"notice_type":{"code":"s","label":"Special Notice"},"schema_version":1,"solicitation_number":"36C24125Q0376","product_service_code":"J041"}],"due_at":"2025-04-11T16:00:00Z","due_date":"2025-04-11","closes_at":"2025-04-11T16:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-18T05:19:57.406887Z","principal_notice_id":"7b49668aebd748108a8a4c5bdfa69a01","description":{"text":"The Department of Veteran Affairs, Networking Contracting Office (NCO1) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Johnson Controls for the following requirement:\nSTATEMENT OF WORK (SOW)\n1.0 Scope of Work\n\nThe contractor will perform chiller maintenance and inspections at the Boston Healthcare System, Brockton Division. Contractor is responsible for all labor, materials, tools and special equipment required to perform the work.\n\n2.0 Performance Requirements\n\nChiller, Water Cooled, Magnetic Bearing Centrifugal, 451-600 Tons\nOperational\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies\nReview control panel for proper operation and recorded fault histories\nCheck for proper condenser and chilled water flow\nCheck system pressures and temperatures\nCheck refrigerant levels\nCheck capacity control and linkage Inspect for signs of refrigerant leakage\nCheck for unusual noise and vibration\nCheck overall condition of unit\nRecord and log all operating parameters For YK, YMC2, YZ, YD, YVAA, YMAA, and YS - Review the Proactive Parts Replacement Tool for components that may be in need of or recommended for proactive replacement.\nRun VSD Diagnostics\nDocument tasks performed during visit and report any observations to appropriate customer representative\nComprehensive\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies\nReview control panel for proper operation and recorded fault histories\nConduct refrigerant leak check Lubricate and check capacity control and linkage\nCheck and tighten electrical connections\nPerform preventative procedures to flow proving devices\nPerform VSD coolant change procedures\nCheck for unusual noise and vibration\nCheck overall condition of unit For YK, YMC2, YZ, YD, YVAA, YMAA, and YS - Review the Proactive Parts Replacement Tool for components that may be in need of or recommended for proactive replacement.\nRun VSD Diagnostics Remove and dispose any debris from any maintenance activity\nDocument tasks performed during visit and report any observations to appropriate customer representative\nCondenser Tube Brushing (removal and replacement of one head only)\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies\nIsolate tubes Drain water from tubes\nRemove head Mechanically brush tubes\nReplace gasket\nReplace head\nRemove and dispose any debris from any maintenance activity\nDocument tasks performed during visit and report any observations to appropriate customer representative\nEvaporator Tube Brushing (removal and replacement of one head only)\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies Isolate tubes Drain water from tubes\nRemove head Mechanically brush tubes\nReplace gasket Replace head\nRemove and dispose any debris from any maintenance activity\nDocument tasks performed during visit and report any observations to appropriate customer representative\nRefrigerant Sample and Analysis\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies\nRemove sample in approved container\nDrop off for analysis\nLabel and complete paperwork indicating present operating conditions\nDocument tasks performed during visit and report any observations to appropriate customer representative\n3.0 Equipment List\n\nJohnson Controls will be awarded this procurement because Johnson Controls (JCI) acquired YORK International in 2005 in which all YORK manufactured chillers are proprietary for integrated JCI controls and systems. JCI is the only contractor with the capability to perform the required services on the YORK controlled chillers. The VA owned JCI system is a proprietary control system and will only have true full compatibility with other YORK/JCI components, software and personnel. Other contractors are unable to perform this work due to not having access to JCI software and replacement supplies.\n\nThe NAICS code for this requirement is 811310 with small business size standard of $12.5 Million.\nThis notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement listed above must clearly identify their capability to do so in writing by April 11, 2025 at 12 pm EST time. Responses should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination by the Government not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.","html":"The Department of Veteran Affairs, Networking Contracting Office (NCO1) located in Brockton, MA intends to enter into a sole source procurement, pursuant to the authority of FAR 6.302-1, with Johnson Controls for the following requirement:\nSTATEMENT OF WORK (SOW)\n1.0 Scope of Work\n\nThe contractor will perform chiller maintenance and inspections at the Boston Healthcare System, Brockton Division. Contractor is responsible for all labor, materials, tools and special equipment required to perform the work.\n\n2.0 Performance Requirements\n\nChiller, Water Cooled, Magnetic Bearing Centrifugal, 451-600 Tons\nOperational \nAll work must be performed in accordance with safety policies \nCheck with appropriate customer representative for operational deficiencies \nReview control panel for proper operation and recorded fault histories \nCheck for proper condenser and chilled water flow\nCheck system pressures and temperatures \nCheck refrigerant levels \nCheck capacity control and linkage Inspect for signs of refrigerant leakage \nCheck for unusual noise and vibration\nCheck overall condition of unit \nRecord and log all operating parameters For YK, YMC2, YZ, YD, YVAA, YMAA, and YS - Review the Proactive Parts Replacement Tool for components that may be in need of or recommended for proactive replacement. \nRun VSD Diagnostics \nDocument tasks performed during visit and report any observations to appropriate customer representative\nComprehensive \nAll work must be performed in accordance with safety policies \nCheck with appropriate customer representative for operational deficiencies \nReview control panel for proper operation and recorded fault histories \nConduct refrigerant leak check Lubricate and check capacity control and linkage \nCheck and tighten electrical connections \nPerform preventative procedures to flow proving devices \nPerform VSD coolant change procedures \nCheck for unusual noise and vibration \nCheck overall condition of unit For YK, YMC2, YZ, YD, YVAA, YMAA, and YS - Review the Proactive Parts Replacement Tool for components that may be in need of or recommended for proactive replacement. \nRun VSD Diagnostics Remove and dispose any debris from any maintenance activity \nDocument tasks performed during visit and report any observations to appropriate customer representative\nCondenser Tube Brushing (removal and replacement of one head only) \nAll work must be performed in accordance with safety policies \nCheck with appropriate customer representative for operational deficiencies \nIsolate tubes Drain water from tubes \nRemove head Mechanically brush tubes \nReplace gasket \nReplace head \nRemove and dispose any debris from any maintenance activity \nDocument tasks performed during visit and report any observations to appropriate customer representative\nEvaporator Tube Brushing (removal and replacement of one head only) \nAll work must be performed in accordance with safety policies \nCheck with appropriate customer representative for operational deficiencies Isolate tubes Drain water from tubes\nRemove head Mechanically brush tubes \nReplace gasket Replace head \nRemove and dispose any debris from any maintenance activity \nDocument tasks performed during visit and report any observations to appropriate customer representative\nRefrigerant Sample and Analysis\nAll work must be performed in accordance with safety policies\nCheck with appropriate customer representative for operational deficiencies \nRemove sample in approved container \nDrop off for analysis \nLabel and complete paperwork indicating present operating conditions \nDocument tasks performed during visit and report any observations to appropriate customer representative\n3.0 Equipment List   \n\n\nJohnson Controls will be awarded this procurement because Johnson Controls (JCI) acquired YORK International in 2005 in which all YORK manufactured chillers are proprietary for integrated JCI controls and systems. JCI is the only contractor with the capability to perform the required services on the YORK controlled chillers.  The VA owned JCI system is a proprietary control system and will only have true full compatibility with other YORK/JCI components, software and personnel. Other contractors are unable to perform this work due to not having access to JCI software and replacement supplies. \n\nThe NAICS code for this requirement is 811310 with small business size standard of $12.5 Million.\nThis notice of intent is not a solicitation nor is it a request for proposal. However, interested parties that believe they can satisfy the requirement listed above must clearly identify their capability to do so in writing by April 11, 2025 at 12 pm EST time. Responses should be sent to Issa Shawki at issa.shawki@va.gov. Information submitted in response to this notice will be used solely to determine whether competitive procedures could be used for this acquisition. A determination by the Government not to open the requirement to competition based upon responses to this notice is solely within the discretion of the Government.","origin":"detail"},"contacts":[{"name":"Issa Shawki","role":"primary","email":"issa.shawki@va.gov","phone":"774-826-3192","title":"Contracting Officer"}],"place_of_performance":null,"office_address":{"zip":"04330","city":"TOGUS","state":"ME","country":"USA"},"naics_codes":["811310"],"award":{"awardee":{}},"attachments":[{"resource_id":"2d9db2b3a6954f849772e5a7a9f3d936","name":"36C24125Q0376.docx","kind":"file","mime_type":".docx","size_bytes":108691,"posted_at":"2025-04-08T20:00:08.051Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2d9db2b3a6954f849772e5a7a9f3d936/download","mirrored":false}],"awards":[],"related":[{"key":"36C24127Q0084","latest_notice_id":"939b8f3021be4a75ae5972b0c7ffb9ae","title":"X1EA--CWM VA Police Use of shooting range.","solicitation_number":"36C24127Q0084","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":"2026-11-27T15:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"611699","psc":"X1EA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"36C24127Q0017","latest_notice_id":"d60676ea33af4051b90a1953ab55743e","title":"S201--36C24127Q0017 Windows Washing Service Amendment 0002","solicitation_number":"36C24127Q0017","notice_type":"k","first_type":"k","first_posted":"2026-10-26","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-27T21:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"561720","psc":"S201","set_aside":"SDVOSBC","state":"MA","county":"25017","county_name":"Middlesex County","city":"2501704615","city_name":"Bedford","country":"USA","place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C24127Q0044","latest_notice_id":"a2f2fe28c1ec4687b2a2955cf947935e","title":"9140--Togus Fuel Oil and Diesel Delivery","solicitation_number":"36C24127Q0044","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"324110","psc":"9140","set_aside":"SBA","state":"ME","county":"23011","county_name":"Kennebec County","city":"2302100","city_name":"Augusta","country":"USA","place_scope":"nationwide","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C24127Q0076","latest_notice_id":"bb30bc78067840a082b5d9e12eceddd2","title":"Q601--Sources sought Boston Medical Coding Period of Period 01/01/2027-04/01/2027","solicitation_number":"36C24127Q0076","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"541219","psc":"Q601","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C24127Q0030","latest_notice_id":"10c3d2d3d0c543179707f8cc9448f701","title":"J061--Eaton Powerware System Replacement","solicitation_number":"36C24127Q0030","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-30T22:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C241","office_name":"241-NETWORK CONTRACT OFFICE 01 (36C241)","naics":"811310","psc":"J061","set_aside":"SDVOSBC","state":"NH","county":"33011","county_name":"Hillsborough County","city":"3345140","city_name":"Manchester","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open":[{"key":"M6740027Q0001","latest_notice_id":"c061b34909a84c19a5fc6ff52f366470","title":"Hydrostatic Testing","solicitation_number":"M6740027Q0001","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-29T23:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-29T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-M67400","office_name":"COMMANDING OFFICER","naics":"811310","psc":"H312","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"JPN","place_scope":"overseas","state_source":null,"state_evidence":"JAPAN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"W51LL527QA003","latest_notice_id":"73068d991fa24e30a387c71a264d24de","title":"EURO-DIESEL DRUPS (DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY)","solicitation_number":"W51LL527QA003","notice_type":"o","first_type":"o","first_posted":"2026-10-30","last_posted":"2026-10-30","notices":1,"due_at":"2026-11-30T04:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T04:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W51LL5","office_name":"0906 AQ CO DET B CONTRACTI","naics":"811310","psc":"J061","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-31T03:50:03.904859Z"},{"key":"80NSSC27948630Q","latest_notice_id":"d4807b9415734ac0a22e33a085b44592","title":"Removal, refurbishment, and reinstallation of two (2) 200 HP General Electric (GE) induction motor at the Unitary Plan Wind Tunnel facility","solicitation_number":"80NSSC27948630Q","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-24","notices":6,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"811310","psc":"J059","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":56,"indexable":false}