{"canonical":"https://sealedbidder.com/opportunities/36c10x26q0183","key":"36C10X26Q0183","url":"https://sealedbidder.com/opportunities/36c10x26q0183","title":"6525--NX EQ Scanning Systems: Cone-Beam Computed Tomography: Head/Neck","solicitation_number":"36C10X26Q0183","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-15T21:30:00Z","first_posted":"2026-06-05","last_posted":"2026-06-05","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"SAC FREDERICK (36C10X)","naics":"339114","psc":"6525","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6525)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"35da4080c25941e3884eee7e1a94e08b","title":"6525--NX EQ Scanning Systems: Cone-Beam Computed Tomography: Head/Neck","solicitation_number":"36C10X26Q0183","notice_type":"r","base_type":"r","posted":"2026-06-05","posted_at":"2026-06-05T16:28:25.902Z","due_at":"2026-06-15T21:30:00Z","due_date":"2026-06-15","cancelled":false,"archived":true,"archive_date":"2026-08-14","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/35da4080c25941e3884eee7e1a94e08b/view","enriched":true,"history":[{"index":3,"title":"6525--NX EQ Scanning Systems: Cone-Beam Computed Tomography: Head/Neck","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-05T16:28:25.902Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"35da4080c25941e3884eee7e1a94e08b","solicitation_number":"36C10X26Q0183"}]}],"latest_notice_id":"35da4080c25941e3884eee7e1a94e08b","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-06-05","posted_at":"2026-06-05T16:28:25.902Z","created_at":"2026-06-05T16:28:23.693Z","modified_at":"2026-08-14T05:07:07.281Z","response_deadline":{"raw":"2026-06-15T16:30:00-05:00","utc":"2026-06-15T21:30:00Z","date":"2026-06-15","time":"16:30:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/35da4080c25941e3884eee7e1a94e08b/view"},"naics":{"codes":["339114"],"primary":"339114"},"title":"6525--NX EQ Scanning Systems: Cone-Beam Computed Tomography: Head/Neck","agency":{"office":{"code":"36C10X","name":"SAC FREDERICK (36C10X)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21703","city":"FREDERICK","state":"MD","country":"USA"},"organization_id":"100173467","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-14","archive_type":"auto_custom"},"history":[{"index":3,"title":"6525--NX EQ Scanning Systems: Cone-Beam Computed Tomography: Head/Neck","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-05T16:28:25.902Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"35da4080c25941e3884eee7e1a94e08b","solicitation_number":"36C10X26Q0183"}],"contacts":[{"name":"Courtney Chattman","role":"primary","email":"Courtney.Chattman@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"35da4080c25941e3884eee7e1a94e08b","lineage_id":"35da4080c25941e3884eee7e1a94e08b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T15:33:44.897434730Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"25806e74dd479a08379393a46e7df5e22a4b785cf7c7da734eaef0deb2759bbe","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-02T15:33:44.897434730Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"DESCRIPTION\n\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Scanning Systems: Cone-Beam Computed Tomography (CBCT): Head/Neck product line as a candidate for an Enterprise-wide (otherwise referred to as  national ) single Requirements contract award. \n\nThe Department of Veterans Affairs  (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with (IAW) the Revolutionary FAR Overhaul (RFO) 10.001(b) to determine the availability and technical capabilities of qualified sources.\n \nThe SAC in conjunction with VHA is seeking a qualified source to provide Carestream Dental CS 9600 or equal CBCT Scanner on an agency wide basis. The VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the CBCT Scanners to VA medical centers and facilities throughout the Continental United States (CONUS) and Outside of the Continental United States (OCONUS) (OCONUS includes locations of Alaska, Hawaii, Puerto Rico, Virgin Islands, Guam, Philippines, American Samoa, and Northern Mariana Islands).\n \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339114 - Dental Equipment and Supplies Manufacturing, Product Service Code: 6525   Imaging Equipment and Supplies: Medical, Dental, Veterinary and the associated size standard is 750 employees. The RFO Provision found at 52.204-7 requires that  The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation in response to this solicitation and at the time of award.  You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nCBCT scanning systems that are designed for neck and/or head imaging, including dental applications. These systems typically consist of: 1) an x-ray subsystem that utilizes a cone beam (i.e., a beam which radiates from the x-ray source in a cone shape) which encompasses a large volume with a single rotation about the patient's head and/or neck thus applying a relatively low dose of radiation; 2) a flat 2D planar detector rather than a curve-shaped detector; 3) image display monitors; 4) a data storage unit; and 5) a computerized subsystem for image processing that is capable of producing high-resolution tri-dimensional (3D) images reconstructed using dedicated software (algorithms). Head/neck CBCT scanning systems are typically used with the patient standing or sitting on a dedicated chair which includes attachments (e.g., supports) to restrain head movements. Many systems combine conventional panoramic dental imaging in the same unit. The systems are used to obtain images for maxillo-facial, oral, and head surgery; they are also used in dental office procedures (e.g., for endodontic treatment, dental implant planning/treatment and/or oral surgery) and provide simultaneous scanning of the maxilla and mandible.\n\nThe following Contract Line-Items Number (CLIN) are being considered:\nContract Line Items\nManufacturer\nPart Number\nDescription\n0001\nCarestream Dental\n1759308\nCS 9600 16x17 W SC Full Bundle- (5yr P&L) Includes Ceph & 5 Years of Parts and Labor Warranty\nFoVs- 4x4, 5x5, 6x6, 5x8, 8x5, 10x5, 12x5, 8x8, 10x10, 12x10, 16x10, 16x12, 16x17\n0002\nCarestream Dental\n1759307\nCS 9600 16x17 Full Bundle- (5 yr P&L) Includes 5 Years of Parts and Labor Warranty\nFoVs- 4x4, 5x5, 6x6, 5x8, 8x5, 10x5, 12x5, 8x8, 10x10, 12x10, 16x10, 16x12, 16x17\n0003\nCarestream Dental\nCS Protect\nExtends the terms of warranty and increase the length of coverage\n0004\nCarestream Dental\nCS Update\nImmediate access to the latest updates available for your software\n0005\nCarestream Dental\nCS Support\nTraining and support for continuing education\n\nThe VA is seeking vendors who can provide Carestream Dental CS 9600 CBCT Scanner or equal as listed above or equal commodities which meet all the following Salient Characteristics (SC):\n\nApply to the following SCs.\n\nSC #\n\nSALIENT CHARACTERISTICS\n\nMETHOD OF EVALUATION\nSC 1\nSystem must be a digital 2-D and 3-D dental-imaging system suitable for panoramic, and scalable cone-beam CT imaging\nLiterature Review\nSC 2\nSystem must also be capable of 3D scanning, such as dual denture scanning and facial scanning.\nLiterature Review\nSC 3\nSystem must provide Line Pair Resolution*: 2.5 lp/mm minimum for image performance.\nLiterature Review\nSC 4\nSystem software must have advanced image reconstruction and post processing suite that support multiplanar reconstruction, 3D volume rendering with metal artifact and motion reduction.\nLiterature Review\nSC 5\nMust be DICOM-3 compliant as well as VistA validated for hardware and software.\nLiterature Review\nSC 6\nData files must be filed in DICOM and STL file formats.\nLiterature Review\nSC 7\nMust provide standing and seated patient positioning.\nLiterature Review\nSC 8\nMust be FDA compliant.\nLiterature Review\nSC 9\nWarranty   Minimum of one-year warranty covering parts and labor.\nLiterature Review\nSC 10\nMust use current DICOM protocols for image processing.\nLiterature Review\nSC 11\nMust provide variable fields of view to obtain necessary diagnostic image and minimize unnecessary exposure to patient.\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\n\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nDUNS number/ CAGE Code/ SAM UIE\n\nBusiness Size\n\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer. \n\nCountry of Origin designation for all products\n\n Ability to provide uninterrupted supply of products on a national scale.\n\n Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n \n Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\n Authorized Distributor Letter certified by OEM and dated within the last 12 months.\n\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","text":"DESCRIPTION\n\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Scanning Systems: Cone-Beam Computed Tomography (CBCT): Head/Neck product line as a candidate for an Enterprise-wide (otherwise referred to as national ) single Requirements contract award.\n\nThe Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with (IAW) the Revolutionary FAR Overhaul (RFO) 10.001(b) to determine the availability and technical capabilities of qualified sources.\n\nThe SAC in conjunction with VHA is seeking a qualified source to provide Carestream Dental CS 9600 or equal CBCT Scanner on an agency wide basis. The VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the CBCT Scanners to VA medical centers and facilities throughout the Continental United States (CONUS) and Outside of the Continental United States (OCONUS) (OCONUS includes locations of Alaska, Hawaii, Puerto Rico, Virgin Islands, Guam, Philippines, American Samoa, and Northern Mariana Islands).\n\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339114 - Dental Equipment and Supplies Manufacturing, Product Service Code: 6525 Imaging Equipment and Supplies: Medical, Dental, Veterinary and the associated size standard is 750 employees. The RFO Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation in response to this solicitation and at the time of award. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nCBCT scanning systems that are designed for neck and/or head imaging, including dental applications. These systems typically consist of: 1) an x-ray subsystem that utilizes a cone beam (i.e., a beam which radiates from the x-ray source in a cone shape) which encompasses a large volume with a single rotation about the patient's head and/or neck thus applying a relatively low dose of radiation; 2) a flat 2D planar detector rather than a curve-shaped detector; 3) image display monitors; 4) a data storage unit; and 5) a computerized subsystem for image processing that is capable of producing high-resolution tri-dimensional (3D) images reconstructed using dedicated software (algorithms). Head/neck CBCT scanning systems are typically used with the patient standing or sitting on a dedicated chair which includes attachments (e.g., supports) to restrain head movements. Many systems combine conventional panoramic dental imaging in the same unit. The systems are used to obtain images for maxillo-facial, oral, and head surgery; they are also used in dental office procedures (e.g., for endodontic treatment, dental implant planning/treatment and/or oral surgery) and provide simultaneous scanning of the maxilla and mandible.\n\nThe following Contract Line-Items Number (CLIN) are being considered:\nContract Line Items\nManufacturer\nPart Number\nDescription\n0001\nCarestream Dental\n1759308\nCS 9600 16x17 W SC Full Bundle- (5yr P&L) Includes Ceph & 5 Years of Parts and Labor Warranty\nFoVs- 4x4, 5x5, 6x6, 5x8, 8x5, 10x5, 12x5, 8x8, 10x10, 12x10, 16x10, 16x12, 16x17\n0002\nCarestream Dental\n1759307\nCS 9600 16x17 Full Bundle- (5 yr P&L) Includes 5 Years of Parts and Labor Warranty\nFoVs- 4x4, 5x5, 6x6, 5x8, 8x5, 10x5, 12x5, 8x8, 10x10, 12x10, 16x10, 16x12, 16x17\n0003\nCarestream Dental\nCS Protect\nExtends the terms of warranty and increase the length of coverage\n0004\nCarestream Dental\nCS Update\nImmediate access to the latest updates available for your software\n0005\nCarestream Dental\nCS Support\nTraining and support for continuing education\n\nThe VA is seeking vendors who can provide Carestream Dental CS 9600 CBCT Scanner or equal as listed above or equal commodities which meet all the following Salient Characteristics (SC):\n\nApply to the following SCs.\n\nSC #\n\nSALIENT CHARACTERISTICS\n\nMETHOD OF EVALUATION\nSC 1\nSystem must be a digital 2-D and 3-D dental-imaging system suitable for panoramic, and scalable cone-beam CT imaging\nLiterature Review\nSC 2\nSystem must also be capable of 3D scanning, such as dual denture scanning and facial scanning.\nLiterature Review\nSC 3\nSystem must provide Line Pair Resolution*: 2.5 lp/mm minimum for image performance.\nLiterature Review\nSC 4\nSystem software must have advanced image reconstruction and post processing suite that support multiplanar reconstruction, 3D volume rendering with metal artifact and motion reduction.\nLiterature Review\nSC 5\nMust be DICOM-3 compliant as well as VistA validated for hardware and software.\nLiterature Review\nSC 6\nData files must be filed in DICOM and STL file formats.\nLiterature Review\nSC 7\nMust provide standing and seated patient positioning.\nLiterature Review\nSC 8\nMust be FDA compliant.\nLiterature Review\nSC 9\nWarranty Minimum of one-year warranty covering parts and labor.\nLiterature Review\nSC 10\nMust use current DICOM protocols for image processing.\nLiterature Review\nSC 11\nMust provide variable fields of view to obtain necessary diagnostic image and minimize unnecessary exposure to patient.\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\n\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nDUNS number/ CAGE Code/ SAM UIE\n\nBusiness Size\n\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer.\n\nCountry of Origin designation for all products\n\nAbility to provide uninterrupted supply of products on a national scale.\n\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAuthorized Distributor Letter certified by OEM and dated within the last 12 months.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10X26Q0183","place_of_performance":{"street":"Nationwide","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6525"}],"due_at":"2026-06-15T21:30:00Z","due_date":"2026-06-15","closes_at":"2026-06-15T21:30:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":"Product purchase (PSC 6525)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-02T15:33:52.429093Z","principal_notice_id":"35da4080c25941e3884eee7e1a94e08b","description":{"text":"DESCRIPTION\n\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Scanning Systems: Cone-Beam Computed Tomography (CBCT): Head/Neck product line as a candidate for an Enterprise-wide (otherwise referred to as national ) single Requirements contract award.\n\nThe Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with (IAW) the Revolutionary FAR Overhaul (RFO) 10.001(b) to determine the availability and technical capabilities of qualified sources.\n\nThe SAC in conjunction with VHA is seeking a qualified source to provide Carestream Dental CS 9600 or equal CBCT Scanner on an agency wide basis. The VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the CBCT Scanners to VA medical centers and facilities throughout the Continental United States (CONUS) and Outside of the Continental United States (OCONUS) (OCONUS includes locations of Alaska, Hawaii, Puerto Rico, Virgin Islands, Guam, Philippines, American Samoa, and Northern Mariana Islands).\n\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339114 - Dental Equipment and Supplies Manufacturing, Product Service Code: 6525 Imaging Equipment and Supplies: Medical, Dental, Veterinary and the associated size standard is 750 employees. The RFO Provision found at 52.204-7 requires that The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation in response to this solicitation and at the time of award. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nCBCT scanning systems that are designed for neck and/or head imaging, including dental applications. These systems typically consist of: 1) an x-ray subsystem that utilizes a cone beam (i.e., a beam which radiates from the x-ray source in a cone shape) which encompasses a large volume with a single rotation about the patient's head and/or neck thus applying a relatively low dose of radiation; 2) a flat 2D planar detector rather than a curve-shaped detector; 3) image display monitors; 4) a data storage unit; and 5) a computerized subsystem for image processing that is capable of producing high-resolution tri-dimensional (3D) images reconstructed using dedicated software (algorithms). Head/neck CBCT scanning systems are typically used with the patient standing or sitting on a dedicated chair which includes attachments (e.g., supports) to restrain head movements. Many systems combine conventional panoramic dental imaging in the same unit. The systems are used to obtain images for maxillo-facial, oral, and head surgery; they are also used in dental office procedures (e.g., for endodontic treatment, dental implant planning/treatment and/or oral surgery) and provide simultaneous scanning of the maxilla and mandible.\n\nThe following Contract Line-Items Number (CLIN) are being considered:\nContract Line Items\nManufacturer\nPart Number\nDescription\n0001\nCarestream Dental\n1759308\nCS 9600 16x17 W SC Full Bundle- (5yr P&L) Includes Ceph & 5 Years of Parts and Labor Warranty\nFoVs- 4x4, 5x5, 6x6, 5x8, 8x5, 10x5, 12x5, 8x8, 10x10, 12x10, 16x10, 16x12, 16x17\n0002\nCarestream Dental\n1759307\nCS 9600 16x17 Full Bundle- (5 yr P&L) Includes 5 Years of Parts and Labor Warranty\nFoVs- 4x4, 5x5, 6x6, 5x8, 8x5, 10x5, 12x5, 8x8, 10x10, 12x10, 16x10, 16x12, 16x17\n0003\nCarestream Dental\nCS Protect\nExtends the terms of warranty and increase the length of coverage\n0004\nCarestream Dental\nCS Update\nImmediate access to the latest updates available for your software\n0005\nCarestream Dental\nCS Support\nTraining and support for continuing education\n\nThe VA is seeking vendors who can provide Carestream Dental CS 9600 CBCT Scanner or equal as listed above or equal commodities which meet all the following Salient Characteristics (SC):\n\nApply to the following SCs.\n\nSC #\n\nSALIENT CHARACTERISTICS\n\nMETHOD OF EVALUATION\nSC 1\nSystem must be a digital 2-D and 3-D dental-imaging system suitable for panoramic, and scalable cone-beam CT imaging\nLiterature Review\nSC 2\nSystem must also be capable of 3D scanning, such as dual denture scanning and facial scanning.\nLiterature Review\nSC 3\nSystem must provide Line Pair Resolution*: 2.5 lp/mm minimum for image performance.\nLiterature Review\nSC 4\nSystem software must have advanced image reconstruction and post processing suite that support multiplanar reconstruction, 3D volume rendering with metal artifact and motion reduction.\nLiterature Review\nSC 5\nMust be DICOM-3 compliant as well as VistA validated for hardware and software.\nLiterature Review\nSC 6\nData files must be filed in DICOM and STL file formats.\nLiterature Review\nSC 7\nMust provide standing and seated patient positioning.\nLiterature Review\nSC 8\nMust be FDA compliant.\nLiterature Review\nSC 9\nWarranty Minimum of one-year warranty covering parts and labor.\nLiterature Review\nSC 10\nMust use current DICOM protocols for image processing.\nLiterature Review\nSC 11\nMust provide variable fields of view to obtain necessary diagnostic image and minimize unnecessary exposure to patient.\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\n\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nDUNS number/ CAGE Code/ SAM UIE\n\nBusiness Size\n\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer.\n\nCountry of Origin designation for all products\n\nAbility to provide uninterrupted supply of products on a national scale.\n\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAuthorized Distributor Letter certified by OEM and dated within the last 12 months.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","html":"DESCRIPTION\n\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Scanning Systems: Cone-Beam Computed Tomography (CBCT): Head/Neck product line as a candidate for an Enterprise-wide (otherwise referred to as  national ) single Requirements contract award. \n\nThe Department of Veterans Affairs  (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with (IAW) the Revolutionary FAR Overhaul (RFO) 10.001(b) to determine the availability and technical capabilities of qualified sources.\n \nThe SAC in conjunction with VHA is seeking a qualified source to provide Carestream Dental CS 9600 or equal CBCT Scanner on an agency wide basis. The VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the CBCT Scanners to VA medical centers and facilities throughout the Continental United States (CONUS) and Outside of the Continental United States (OCONUS) (OCONUS includes locations of Alaska, Hawaii, Puerto Rico, Virgin Islands, Guam, Philippines, American Samoa, and Northern Mariana Islands).\n \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339114 - Dental Equipment and Supplies Manufacturing, Product Service Code: 6525   Imaging Equipment and Supplies: Medical, Dental, Veterinary and the associated size standard is 750 employees. The RFO Provision found at 52.204-7 requires that  The Offeror shall have an active Federal Government contracts registration in the System for Award Management (SAM) when submitting an offer or quotation in response to this solicitation and at the time of award.  You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nCBCT scanning systems that are designed for neck and/or head imaging, including dental applications. These systems typically consist of: 1) an x-ray subsystem that utilizes a cone beam (i.e., a beam which radiates from the x-ray source in a cone shape) which encompasses a large volume with a single rotation about the patient's head and/or neck thus applying a relatively low dose of radiation; 2) a flat 2D planar detector rather than a curve-shaped detector; 3) image display monitors; 4) a data storage unit; and 5) a computerized subsystem for image processing that is capable of producing high-resolution tri-dimensional (3D) images reconstructed using dedicated software (algorithms). Head/neck CBCT scanning systems are typically used with the patient standing or sitting on a dedicated chair which includes attachments (e.g., supports) to restrain head movements. Many systems combine conventional panoramic dental imaging in the same unit. The systems are used to obtain images for maxillo-facial, oral, and head surgery; they are also used in dental office procedures (e.g., for endodontic treatment, dental implant planning/treatment and/or oral surgery) and provide simultaneous scanning of the maxilla and mandible.\n\nThe following Contract Line-Items Number (CLIN) are being considered:\nContract Line Items\nManufacturer\nPart Number\nDescription\n0001\nCarestream Dental\n1759308\nCS 9600 16x17 W SC Full Bundle- (5yr P&L) Includes Ceph & 5 Years of Parts and Labor Warranty\nFoVs- 4x4, 5x5, 6x6, 5x8, 8x5, 10x5, 12x5, 8x8, 10x10, 12x10, 16x10, 16x12, 16x17\n0002\nCarestream Dental\n1759307\nCS 9600 16x17 Full Bundle- (5 yr P&L) Includes 5 Years of Parts and Labor Warranty\nFoVs- 4x4, 5x5, 6x6, 5x8, 8x5, 10x5, 12x5, 8x8, 10x10, 12x10, 16x10, 16x12, 16x17\n0003\nCarestream Dental\nCS Protect\nExtends the terms of warranty and increase the length of coverage\n0004\nCarestream Dental\nCS Update\nImmediate access to the latest updates available for your software\n0005\nCarestream Dental\nCS Support\nTraining and support for continuing education\n\nThe VA is seeking vendors who can provide Carestream Dental CS 9600 CBCT Scanner or equal as listed above or equal commodities which meet all the following Salient Characteristics (SC):\n\nApply to the following SCs.\n\nSC #\n\nSALIENT CHARACTERISTICS\n\nMETHOD OF EVALUATION\nSC 1\nSystem must be a digital 2-D and 3-D dental-imaging system suitable for panoramic, and scalable cone-beam CT imaging\nLiterature Review\nSC 2\nSystem must also be capable of 3D scanning, such as dual denture scanning and facial scanning.\nLiterature Review\nSC 3\nSystem must provide Line Pair Resolution*: 2.5 lp/mm minimum for image performance.\nLiterature Review\nSC 4\nSystem software must have advanced image reconstruction and post processing suite that support multiplanar reconstruction, 3D volume rendering with metal artifact and motion reduction.\nLiterature Review\nSC 5\nMust be DICOM-3 compliant as well as VistA validated for hardware and software.\nLiterature Review\nSC 6\nData files must be filed in DICOM and STL file formats.\nLiterature Review\nSC 7\nMust provide standing and seated patient positioning.\nLiterature Review\nSC 8\nMust be FDA compliant.\nLiterature Review\nSC 9\nWarranty   Minimum of one-year warranty covering parts and labor.\nLiterature Review\nSC 10\nMust use current DICOM protocols for image processing.\nLiterature Review\nSC 11\nMust provide variable fields of view to obtain necessary diagnostic image and minimize unnecessary exposure to patient.\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\n\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nDUNS number/ CAGE Code/ SAM UIE\n\nBusiness Size\n\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer. \n\nCountry of Origin designation for all products\n\n Ability to provide uninterrupted supply of products on a national scale.\n\n Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n \n Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\n Authorized Distributor Letter certified by OEM and dated within the last 12 months.\n\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"contacts":[{"name":"Courtney Chattman","role":"primary","email":"Courtney.Chattman@va.gov","title":"Contract Specialist"}],"place_of_performance":{"street":"Nationwide","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"21703","city":"FREDERICK","state":"MD","country":"USA"},"naics_codes":["339114"],"award":{"awardee":{}},"attachments":[{"resource_id":"b94c4db50fc2442a9b3f2534fb961b4e","name":"36C10X26Q0183.docx","kind":"file","mime_type":".docx","size_bytes":32179,"posted_at":"2026-06-05T16:28:25.902Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b94c4db50fc2442a9b3f2534fb961b4e/download","mirrored":false}],"awards":[],"related":[{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C10X27AP0258","latest_notice_id":"e036efc9a96b464fbc236b83dc31bc84","title":"Urgent - Independent Medical Expert Advisory Opinion | Neurosurgery or Orthopedic Surgery","solicitation_number":"36C10X27-AP-0258","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T15:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"541690","psc":"Q403","set_aside":null,"state":"DC","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C10X27R0005","latest_notice_id":"e932ae7c1a2641ef910a7fa47204c74e","title":"6515--NX EQ Ultrasonic Aspirator System: Tissue Ablation (VA-27-00010132)","solicitation_number":"36C10X27R0005","notice_type":"k","first_type":"k","first_posted":"2026-11-09","last_posted":"2026-11-18","notices":3,"due_at":"2026-12-01T15:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C10X27Q0033","latest_notice_id":"2bf06c09e95d4059b2bdae0c88e09c15","title":"6515--Copy of NX EQ Thulium Fiber Laser (VA-27-00003102)","solicitation_number":"36C10X27Q0033","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-11T04:59:00Z","due_date":"2026-12-10","closes_at":"2026-12-11T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C10X27R0009","latest_notice_id":"7d952ac4057244e2b055bdda8074cd26","title":"Burial Flags - Commercial","solicitation_number":"36C10X27R0009","notice_type":"o","first_type":"o","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":3,"due_at":"2026-12-15T16:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"314999","psc":"8345","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8345)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"}],"similar_open":[],"similar_open_total":0,"indexable":false}