{"canonical":"https://sealedbidder.com/opportunities/36c10x26q0086","key":"36C10X26Q0086","url":"https://sealedbidder.com/opportunities/36c10x26q0086","title":"6515--Physiologic Monitor Modules: Pulse Oximetry","solicitation_number":"36C10X26Q0086","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-16T14:00:00Z","first_posted":"2026-03-04","last_posted":"2026-03-04","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"65d40b0c40ff4406b35ec3e7fdb9473b","title":"6515--Physiologic Monitor Modules: Pulse Oximetry","solicitation_number":"36C10X26Q0086","notice_type":"r","base_type":"r","posted":"2026-03-04","posted_at":"2026-03-04T15:35:28.414Z","due_at":"2026-03-16T14:00:00Z","due_date":"2026-03-16","cancelled":false,"archived":true,"archive_date":"2026-06-23","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/65d40b0c40ff4406b35ec3e7fdb9473b/view","enriched":true,"history":[{"index":3,"title":"6515--Physiologic Monitor Modules: Pulse Oximetry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-04T15:35:28.414Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"65d40b0c40ff4406b35ec3e7fdb9473b","solicitation_number":"36C10X26Q0086"}]}],"latest_notice_id":"65d40b0c40ff4406b35ec3e7fdb9473b","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-03-04","posted_at":"2026-03-04T15:35:28.414Z","created_at":"2026-03-04T15:35:26.219Z","modified_at":"2026-06-24T03:55:45.517Z","response_deadline":{"raw":"2026-03-16T10:00:00-04:00","utc":"2026-03-16T14:00:00Z","date":"2026-03-16","time":"10:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/65d40b0c40ff4406b35ec3e7fdb9473b/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--Physiologic Monitor Modules: Pulse Oximetry","agency":{"office":{"code":"36C10X","name":"SAC FREDERICK (36C10X)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"21703","city":"FREDERICK","state":"MD","country":"USA"},"organization_id":"100173467","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-23","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--Physiologic Monitor Modules: Pulse Oximetry","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-04T15:35:28.414Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"65d40b0c40ff4406b35ec3e7fdb9473b","solicitation_number":"36C10X26Q0086"}],"contacts":[{"name":"Jalima J. Jones","role":"primary","email":"Jalima.Jones@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"65d40b0c40ff4406b35ec3e7fdb9473b","lineage_id":"65d40b0c40ff4406b35ec3e7fdb9473b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-12T00:23:17.896961210Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"51bf3d3f4c367755804a88cfd6c5f4e15dd06f8a640987c31dd4e57311fd7e85","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-12T00:23:17.896961210Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"Page 6 of 6\nDESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Physiologic Monitor Modules: Pulse Oximetry product line as a candidate for a VA-wide (otherwise referred to as  national ) single Requirements contract award.  \nThe Department of Veterans Affairs  (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. \nThe SAC in conjunction with VHA is seeking a qualified source to provide MasimoÂ® brand name or equal to the Physiologic Monitor Modules: Pulse Oximetry on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Physiologic Monitor Modules: Pulse Oximetry to VA medical centers and facilities throughout the United States and its territories. \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Surgical and Medical Instrument Manufacturing, Product Service Code: 6515   Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 1000 employees. The FAR Provision found at 52.204-7(b)(1) requires that  All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation.  You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.\nSubmissions for this  source sought  shall be submitted by email no later than March 16th, 2026, at 10:00 am EST to all the following:\nJalima.Jones@va.gov\nSara.Vickroy@va.gov\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\nThe Physiologic Monitor Modules: Pulse Oximetry is a noninvasive patient monitoring system that continuously measures regional hemoglobin oxygen saturation specific tissues, such as the brain during anesthesia. It utilizes near-infrared spectroscopy (NIRS) technology through sensors placed on the skin, typically the forehead, to determine the balance between regional oxygen delivery and demand. The device's primary purpose is to provide clinicians with deeper insights into a patient's localized oxygen status, which general peripheral pulse oximetry alone might miss. By detecting regional hypoxemia (low oxygen levels) in vital organs, the O3 oximeter helps guide early clinical interventions. This additional information helps healthcare providers make more informed decisions to potentially improve patient outcomes during surgery or intensive care.\nThe following Contract Line-Items Number (CLIN) are being considered:\nCLIN\nManufacturer\nPart Number\nDescription\n0001\nMasimoÂ®\n9515\nRoot Monitor\n0002\nMasimoÂ®\n9637\nO3 Regional Oximeter Module\n0003\nMasimoÂ®\n3756\nO3 Sensor, Adult (20/box)\n0004\nMasimoÂ®\n4575\nO3 Module Clamp\n0005\nCurbell Medical\n15785\nCurbell Cable Tethers, 6\" (12/box)\n0006\nMasimoÂ®\n300238\nRoot Roll Stand \n0007\nMasimoÂ®\n28814\nDLMS Virtual Server\n0008\nMasimoÂ®\n27161\nBAG ASSY, IRIS GTWY VIRTL APPL, V2.0.0.1\n0009\nMasimoÂ®\n27274\nBAG ASY, IRIS GTWY VRT APPL, TST SVR,V2001\n0010\nMasimoÂ®\n101138\nUSB 1D/2D BARCODE READER\n0011\nMasimoÂ®\n3963\nHL7, ADT, INTERFACE\n0012\nMasimoÂ®\n4526\nHL7, NOTIFCATIONS\n0013\nMasimoÂ®\n3964\nHL7, RESULTS OUT, INTERFACE\n0014\nMasimoÂ®\n2456\nINSTALLATION SERVICES, SAFETY NET\n0015\nMasimoÂ®\n9712-LIC\nIRIS DCX PER BED LICENSE\n0016\nMasimoÂ®\n102-3Y\nIRIS SERVICE, 3 Yr\n0017\nMasimoÂ®\n2457\nWIRELESS SITE SURVEY\n0018\nMasimoÂ®\n114-3Y\nCONCIERGE+ SERVICE PLAN FOR DEVICES, 3YR\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide MasimoÂ® brand name or equal to Physiologic Monitor Modules: Pulse Oximetry as listed above or equal commodities which meet all the following salient characteristics (SCs):\nSC #\nSALIENT CHARACTERISTICS\nApplicable CLIN\nMETHOD OF EVALUATION\nSC 1\nMust provide continuous non-invasive Cerebral oxygen saturation (rSO ) values\n\n0001- 0003\nLiterature Review\nSC 2\nMust allow for placement of bilateral sensors to assess cerebral oxygenation.\n\n0001- 0003\nLiterature Review\nSC 3\nMust provide configurable alarms for cerebral desaturation thresholds.\n\n0001 - 0002\nLiterature Review\nSC 4\nData Output/Connectivity   Must support export of oximetry data for integration with hospital information systems (e.g., HL7, CIS/ARK, etc.).\n\n0001, 0007, 0015\nLiterature Review\nSC 5\nRegulatory Approval   Must have FDA clearance for cerebral oximetry applications in anesthesiology and perioperative care.\n\n0001 - 0003\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration as long they meet the Salient Characteristic. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No? \nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\nVendors are requested to provide documentation that shows information on their service plan.\nIs the service provided by the OEM or a subcontractor?\nFull name and address of company\nCAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf the distributor provides full name, business size and address of manufacturer. \nCountry of Origin designation for all products\nAbility to provide uninterrupted supply of products on a national scale.\nTechnical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met. \nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","text":"Page 6 of 6\nDESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Physiologic Monitor Modules: Pulse Oximetry product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.\nThe Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.\nThe SAC in conjunction with VHA is seeking a qualified source to provide MasimoÂ® brand name or equal to the Physiologic Monitor Modules: Pulse Oximetry on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Physiologic Monitor Modules: Pulse Oximetry to VA medical centers and facilities throughout the United States and its territories.\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Surgical and Medical Instrument Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 1000 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.\nSubmissions for this source sought shall be submitted by email no later than March 16th, 2026, at 10:00 am EST to all the following:\nJalima.Jones@va.gov\nSara.Vickroy@va.gov\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\nThe Physiologic Monitor Modules: Pulse Oximetry is a noninvasive patient monitoring system that continuously measures regional hemoglobin oxygen saturation specific tissues, such as the brain during anesthesia. It utilizes near-infrared spectroscopy (NIRS) technology through sensors placed on the skin, typically the forehead, to determine the balance between regional oxygen delivery and demand. The device's primary purpose is to provide clinicians with deeper insights into a patient's localized oxygen status, which general peripheral pulse oximetry alone might miss. By detecting regional hypoxemia (low oxygen levels) in vital organs, the O3 oximeter helps guide early clinical interventions. This additional information helps healthcare providers make more informed decisions to potentially improve patient outcomes during surgery or intensive care.\nThe following Contract Line-Items Number (CLIN) are being considered:\nCLIN\nManufacturer\nPart Number\nDescription\n0001\nMasimoÂ®\n9515\nRoot Monitor\n0002\nMasimoÂ®\n9637\nO3 Regional Oximeter Module\n0003\nMasimoÂ®\n3756\nO3 Sensor, Adult (20/box)\n0004\nMasimoÂ®\n4575\nO3 Module Clamp\n0005\nCurbell Medical\n15785\nCurbell Cable Tethers, 6\" (12/box)\n0006\nMasimoÂ®\n300238\nRoot Roll Stand\n0007\nMasimoÂ®\n28814\nDLMS Virtual Server\n0008\nMasimoÂ®\n27161\nBAG ASSY, IRIS GTWY VIRTL APPL, V2.0.0.1\n0009\nMasimoÂ®\n27274\nBAG ASY, IRIS GTWY VRT APPL, TST SVR,V2001\n0010\nMasimoÂ®\n101138\nUSB 1D/2D BARCODE READER\n0011\nMasimoÂ®\n3963\nHL7, ADT, INTERFACE\n0012\nMasimoÂ®\n4526\nHL7, NOTIFCATIONS\n0013\nMasimoÂ®\n3964\nHL7, RESULTS OUT, INTERFACE\n0014\nMasimoÂ®\n2456\nINSTALLATION SERVICES, SAFETY NET\n0015\nMasimoÂ®\n9712-LIC\nIRIS DCX PER BED LICENSE\n0016\nMasimoÂ®\n102-3Y\nIRIS SERVICE, 3 Yr\n0017\nMasimoÂ®\n2457\nWIRELESS SITE SURVEY\n0018\nMasimoÂ®\n114-3Y\nCONCIERGE+ SERVICE PLAN FOR DEVICES, 3YR\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide MasimoÂ® brand name or equal to Physiologic Monitor Modules: Pulse Oximetry as listed above or equal commodities which meet all the following salient characteristics (SCs):\nSC #\nSALIENT CHARACTERISTICS\nApplicable CLIN\nMETHOD OF EVALUATION\nSC 1\nMust provide continuous non-invasive Cerebral oxygen saturation (rSO ) values\n\n0001- 0003\nLiterature Review\nSC 2\nMust allow for placement of bilateral sensors to assess cerebral oxygenation.\n\n0001- 0003\nLiterature Review\nSC 3\nMust provide configurable alarms for cerebral desaturation thresholds.\n\n0001 - 0002\nLiterature Review\nSC 4\nData Output/Connectivity Must support export of oximetry data for integration with hospital information systems (e.g., HL7, CIS/ARK, etc.).\n\n0001, 0007, 0015\nLiterature Review\nSC 5\nRegulatory Approval Must have FDA clearance for cerebral oximetry applications in anesthesiology and perioperative care.\n\n0001 - 0003\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration as long they meet the Salient Characteristic. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No?\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\nVendors are requested to provide documentation that shows information on their service plan.\nIs the service provided by the OEM or a subcontractor?\nFull name and address of company\nCAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf the distributor provides full name, business size and address of manufacturer.\nCountry of Origin designation for all products\nAbility to provide uninterrupted supply of products on a national scale.\nTechnical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met.\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10X26Q0086","place_of_performance":{"street":"Nationwide"},"product_service_code":"6515"}],"due_at":"2026-03-16T14:00:00Z","due_date":"2026-03-16","closes_at":"2026-03-16T14:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-12T01:11:11.396115Z","principal_notice_id":"65d40b0c40ff4406b35ec3e7fdb9473b","description":{"text":"Page 6 of 6\nDESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Physiologic Monitor Modules: Pulse Oximetry product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.\nThe Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.\nThe SAC in conjunction with VHA is seeking a qualified source to provide MasimoÂ® brand name or equal to the Physiologic Monitor Modules: Pulse Oximetry on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Physiologic Monitor Modules: Pulse Oximetry to VA medical centers and facilities throughout the United States and its territories.\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Surgical and Medical Instrument Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 1000 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.\nSubmissions for this source sought shall be submitted by email no later than March 16th, 2026, at 10:00 am EST to all the following:\nJalima.Jones@va.gov\nSara.Vickroy@va.gov\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\nThe Physiologic Monitor Modules: Pulse Oximetry is a noninvasive patient monitoring system that continuously measures regional hemoglobin oxygen saturation specific tissues, such as the brain during anesthesia. It utilizes near-infrared spectroscopy (NIRS) technology through sensors placed on the skin, typically the forehead, to determine the balance between regional oxygen delivery and demand. The device's primary purpose is to provide clinicians with deeper insights into a patient's localized oxygen status, which general peripheral pulse oximetry alone might miss. By detecting regional hypoxemia (low oxygen levels) in vital organs, the O3 oximeter helps guide early clinical interventions. This additional information helps healthcare providers make more informed decisions to potentially improve patient outcomes during surgery or intensive care.\nThe following Contract Line-Items Number (CLIN) are being considered:\nCLIN\nManufacturer\nPart Number\nDescription\n0001\nMasimoÂ®\n9515\nRoot Monitor\n0002\nMasimoÂ®\n9637\nO3 Regional Oximeter Module\n0003\nMasimoÂ®\n3756\nO3 Sensor, Adult (20/box)\n0004\nMasimoÂ®\n4575\nO3 Module Clamp\n0005\nCurbell Medical\n15785\nCurbell Cable Tethers, 6\" (12/box)\n0006\nMasimoÂ®\n300238\nRoot Roll Stand\n0007\nMasimoÂ®\n28814\nDLMS Virtual Server\n0008\nMasimoÂ®\n27161\nBAG ASSY, IRIS GTWY VIRTL APPL, V2.0.0.1\n0009\nMasimoÂ®\n27274\nBAG ASY, IRIS GTWY VRT APPL, TST SVR,V2001\n0010\nMasimoÂ®\n101138\nUSB 1D/2D BARCODE READER\n0011\nMasimoÂ®\n3963\nHL7, ADT, INTERFACE\n0012\nMasimoÂ®\n4526\nHL7, NOTIFCATIONS\n0013\nMasimoÂ®\n3964\nHL7, RESULTS OUT, INTERFACE\n0014\nMasimoÂ®\n2456\nINSTALLATION SERVICES, SAFETY NET\n0015\nMasimoÂ®\n9712-LIC\nIRIS DCX PER BED LICENSE\n0016\nMasimoÂ®\n102-3Y\nIRIS SERVICE, 3 Yr\n0017\nMasimoÂ®\n2457\nWIRELESS SITE SURVEY\n0018\nMasimoÂ®\n114-3Y\nCONCIERGE+ SERVICE PLAN FOR DEVICES, 3YR\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide MasimoÂ® brand name or equal to Physiologic Monitor Modules: Pulse Oximetry as listed above or equal commodities which meet all the following salient characteristics (SCs):\nSC #\nSALIENT CHARACTERISTICS\nApplicable CLIN\nMETHOD OF EVALUATION\nSC 1\nMust provide continuous non-invasive Cerebral oxygen saturation (rSO ) values\n\n0001- 0003\nLiterature Review\nSC 2\nMust allow for placement of bilateral sensors to assess cerebral oxygenation.\n\n0001- 0003\nLiterature Review\nSC 3\nMust provide configurable alarms for cerebral desaturation thresholds.\n\n0001 - 0002\nLiterature Review\nSC 4\nData Output/Connectivity Must support export of oximetry data for integration with hospital information systems (e.g., HL7, CIS/ARK, etc.).\n\n0001, 0007, 0015\nLiterature Review\nSC 5\nRegulatory Approval Must have FDA clearance for cerebral oximetry applications in anesthesiology and perioperative care.\n\n0001 - 0003\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration as long they meet the Salient Characteristic. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No?\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\nVendors are requested to provide documentation that shows information on their service plan.\nIs the service provided by the OEM or a subcontractor?\nFull name and address of company\nCAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf the distributor provides full name, business size and address of manufacturer.\nCountry of Origin designation for all products\nAbility to provide uninterrupted supply of products on a national scale.\nTechnical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met.\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","html":"Page 6 of 6\nDESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Physiologic Monitor Modules: Pulse Oximetry product line as a candidate for a VA-wide (otherwise referred to as  national ) single Requirements contract award.  \nThe Department of Veterans Affairs  (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. \nThe SAC in conjunction with VHA is seeking a qualified source to provide MasimoÂ® brand name or equal to the Physiologic Monitor Modules: Pulse Oximetry on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Physiologic Monitor Modules: Pulse Oximetry to VA medical centers and facilities throughout the United States and its territories. \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112- Surgical and Medical Instrument Manufacturing, Product Service Code: 6515   Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 1000 employees. The FAR Provision found at 52.204-7(b)(1) requires that  All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation.  You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.\nSubmissions for this  source sought  shall be submitted by email no later than March 16th, 2026, at 10:00 am EST to all the following:\nJalima.Jones@va.gov\nSara.Vickroy@va.gov\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\nThe Physiologic Monitor Modules: Pulse Oximetry is a noninvasive patient monitoring system that continuously measures regional hemoglobin oxygen saturation specific tissues, such as the brain during anesthesia. It utilizes near-infrared spectroscopy (NIRS) technology through sensors placed on the skin, typically the forehead, to determine the balance between regional oxygen delivery and demand. The device's primary purpose is to provide clinicians with deeper insights into a patient's localized oxygen status, which general peripheral pulse oximetry alone might miss. By detecting regional hypoxemia (low oxygen levels) in vital organs, the O3 oximeter helps guide early clinical interventions. This additional information helps healthcare providers make more informed decisions to potentially improve patient outcomes during surgery or intensive care.\nThe following Contract Line-Items Number (CLIN) are being considered:\nCLIN\nManufacturer\nPart Number\nDescription\n0001\nMasimoÂ®\n9515\nRoot Monitor\n0002\nMasimoÂ®\n9637\nO3 Regional Oximeter Module\n0003\nMasimoÂ®\n3756\nO3 Sensor, Adult (20/box)\n0004\nMasimoÂ®\n4575\nO3 Module Clamp\n0005\nCurbell Medical\n15785\nCurbell Cable Tethers, 6\" (12/box)\n0006\nMasimoÂ®\n300238\nRoot Roll Stand \n0007\nMasimoÂ®\n28814\nDLMS Virtual Server\n0008\nMasimoÂ®\n27161\nBAG ASSY, IRIS GTWY VIRTL APPL, V2.0.0.1\n0009\nMasimoÂ®\n27274\nBAG ASY, IRIS GTWY VRT APPL, TST SVR,V2001\n0010\nMasimoÂ®\n101138\nUSB 1D/2D BARCODE READER\n0011\nMasimoÂ®\n3963\nHL7, ADT, INTERFACE\n0012\nMasimoÂ®\n4526\nHL7, NOTIFCATIONS\n0013\nMasimoÂ®\n3964\nHL7, RESULTS OUT, INTERFACE\n0014\nMasimoÂ®\n2456\nINSTALLATION SERVICES, SAFETY NET\n0015\nMasimoÂ®\n9712-LIC\nIRIS DCX PER BED LICENSE\n0016\nMasimoÂ®\n102-3Y\nIRIS SERVICE, 3 Yr\n0017\nMasimoÂ®\n2457\nWIRELESS SITE SURVEY\n0018\nMasimoÂ®\n114-3Y\nCONCIERGE+ SERVICE PLAN FOR DEVICES, 3YR\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide MasimoÂ® brand name or equal to Physiologic Monitor Modules: Pulse Oximetry as listed above or equal commodities which meet all the following salient characteristics (SCs):\nSC #\nSALIENT CHARACTERISTICS\nApplicable CLIN\nMETHOD OF EVALUATION\nSC 1\nMust provide continuous non-invasive Cerebral oxygen saturation (rSO ) values\n\n0001- 0003\nLiterature Review\nSC 2\nMust allow for placement of bilateral sensors to assess cerebral oxygenation.\n\n0001- 0003\nLiterature Review\nSC 3\nMust provide configurable alarms for cerebral desaturation thresholds.\n\n0001 - 0002\nLiterature Review\nSC 4\nData Output/Connectivity   Must support export of oximetry data for integration with hospital information systems (e.g., HL7, CIS/ARK, etc.).\n\n0001, 0007, 0015\nLiterature Review\nSC 5\nRegulatory Approval   Must have FDA clearance for cerebral oximetry applications in anesthesiology and perioperative care.\n\n0001 - 0003\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration as long they meet the Salient Characteristic. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No? \nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\nVendors are requested to provide documentation that shows information on their service plan.\nIs the service provided by the OEM or a subcontractor?\nFull name and address of company\nCAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf the distributor provides full name, business size and address of manufacturer. \nCountry of Origin designation for all products\nAbility to provide uninterrupted supply of products on a national scale.\nTechnical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met. \nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"contacts":[{"name":"Jalima J. Jones","role":"primary","email":"Jalima.Jones@va.gov","title":"Contract Specialist"}],"place_of_performance":{"street":"Nationwide"},"office_address":{"zip":"21703","city":"FREDERICK","state":"MD","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"bdee04f1695b494180a286b49ecb9471","name":"36C10X26Q0086.docx","kind":"file","mime_type":".docx","size_bytes":24557,"posted_at":"2026-03-04T15:35:28.414Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/bdee04f1695b494180a286b49ecb9471/download","mirrored":false}],"awards":[],"related":[{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"36C10X27AP0258","latest_notice_id":"e036efc9a96b464fbc236b83dc31bc84","title":"Urgent - Independent Medical Expert Advisory Opinion | Neurosurgery or Orthopedic Surgery","solicitation_number":"36C10X27-AP-0258","notice_type":"r","first_type":"r","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T15:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"541690","psc":"Q403","set_aside":null,"state":"DC","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C10X27R0005","latest_notice_id":"e932ae7c1a2641ef910a7fa47204c74e","title":"6515--NX EQ Ultrasonic Aspirator System: Tissue Ablation (VA-27-00010132)","solicitation_number":"36C10X27R0005","notice_type":"k","first_type":"k","first_posted":"2026-11-09","last_posted":"2026-11-18","notices":3,"due_at":"2026-12-01T15:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C10X27Q0033","latest_notice_id":"2bf06c09e95d4059b2bdae0c88e09c15","title":"6515--Copy of NX EQ Thulium Fiber Laser (VA-27-00003102)","solicitation_number":"36C10X27Q0033","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-11T04:59:00Z","due_date":"2026-12-10","closes_at":"2026-12-11T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C10X27R0009","latest_notice_id":"7d952ac4057244e2b055bdda8074cd26","title":"Burial Flags - Commercial","solicitation_number":"36C10X27R0009","notice_type":"o","first_type":"o","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":3,"due_at":"2026-12-15T16:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"314999","psc":"8345","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 8345)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"SPE2DS27T2443","latest_notice_id":"8f83cd5d4eb6487083e3a8ace6f5842d","title":"65--TEST KIT,MICRO SAMPLE","solicitation_number":"SPE2DS27T2443","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":null,"due_date":"2026-11-30","closes_at":"2026-12-01T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE2DS","office_name":"DLA TROOP SUPPORT","naics":"339112","psc":"65","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"SAMPLE: LINE 0001 QTY 4 UI EA DELIVER TO: AMC BAMC FSH - MM BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":15,"indexable":false}