{"canonical":"https://sealedbidder.com/opportunities/36c10g26q0035","key":"36C10G26Q0035","url":"https://sealedbidder.com/opportunities/36c10g26q0035","title":"6515--NX EQ Electrosurgical Units, Argon-Enhanced Coagulation (VA-26-00034663) (VA-26-00034663)","solicitation_number":"36C10G26Q0035","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-01-27T04:59:00Z","first_posted":"2026-01-12","last_posted":"2026-01-12","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"339112","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"403af7f4043348c3bb4c645238dfc252","title":"6515--NX EQ Electrosurgical Units, Argon-Enhanced Coagulation (VA-26-00034663) (VA-26-00034663)","solicitation_number":"36C10G26Q0035","notice_type":"r","base_type":"r","posted":"2026-01-12","posted_at":"2026-01-12T15:28:37.998Z","due_at":"2026-01-27T04:59:00Z","due_date":"2026-01-26","cancelled":false,"archived":true,"archive_date":"2026-03-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/403af7f4043348c3bb4c645238dfc252/view","enriched":true,"history":[{"index":3,"title":"6515--NX EQ Electrosurgical Units, Argon-Enhanced Coagulation (VA-26-00034663) (VA-26-00034663)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-12T15:28:37.998Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"403af7f4043348c3bb4c645238dfc252","solicitation_number":"36C10G26Q0035"}]}],"latest_notice_id":"403af7f4043348c3bb4c645238dfc252","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2026-01-12","posted_at":"2026-01-12T15:28:37.998Z","created_at":"2026-01-12T15:28:35.825Z","modified_at":"2026-03-28T04:06:42.662Z","response_deadline":{"raw":"2026-01-26T23:59:00-05:00","utc":"2026-01-27T04:59:00Z","date":"2026-01-26","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/403af7f4043348c3bb4c645238dfc252/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"6515--NX EQ Electrosurgical Units, Argon-Enhanced Coagulation (VA-26-00034663) (VA-26-00034663)","agency":{"office":{"code":"36C10G","name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"organization_id":"100167093","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-27","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--NX EQ Electrosurgical Units, Argon-Enhanced Coagulation (VA-26-00034663) (VA-26-00034663)","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-01-12T15:28:37.998Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"403af7f4043348c3bb4c645238dfc252","solicitation_number":"36C10G26Q0035"}],"contacts":[{"fax":"Hosea Berkley","name":"Daleta Coles","role":"primary","email":"daleta.coles@va.gov","phone":"Contracting Officer","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"403af7f4043348c3bb4c645238dfc252","lineage_id":"403af7f4043348c3bb4c645238dfc252","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-16T03:15:12.058752994Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"7fb8ca1a422b940669cfaf2144dde1a22f2ef11399ea643685b0a3adfda5b7cc","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-16T03:15:12.058752994Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified Electrosurgical Units (ESUs); Argon-Enhanced Coagulation product line as a candidate for a VA-wide (otherwise referred to as  national ) single Requirements contract award.  \n\nThe Department of Veterans Affairs  (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Request for Information (RFI) in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. The period of performance will consist of a base of 12-months with four 12-month option periods from the date of award. \nThe SAC in conjunction with VHA is seeking a qualified source to manufacture Electrosurgical Units (ESUs); Argon-Enhanced Coagulation on an agency wide basis. VA intends to award a Brand Name or Equal (BNOE) single award Requirements contract for this requirement IAW with FAR 16.503. Vendors will be required to deliver Electrosurgical Units (ESUs); Argon-Enhanced Coagulation to VA medical centers and facilities throughout the United States.  \nThe anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112 Surgical and Medical Instrument Manufacturing and the associated size standard is 1,000 employees. The FAR Provision found at 52.204-7 requires that  All interested Offerors must be registered in SAM prior to submitting an offer or proposal.  You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nElectrosurgical Units (ESUs); Argon-Enhanced Coagulation (AEC) are advanced, energy based surgical systems used to perform precise tissue coagulation and devitalization across Veterans Affairs Medical Centers (VAMCs), particularly in operating rooms (OR), procedural suites, and endoscopy units. They deliver radiofrequency (RF) energy through specialized electrodes while directing a controlled flow of inert argon gas to create a conductive plasma at the tissue surface. This results in uniform, noncontact coagulation with minimal tissue penetration, improved visualization, and reduced bleeding. ESUs with AEC are designed to enhance surgical efficiency, improve hemostasis, and support consistent, replicable outcomes across a range of open, laparoscopic, and endoscopic procedures.\n\nThese systems provide real-time, automated control of power delivery, argon flow, and activation mode, with integrated safety monitoring and configurable presets for procedure-specific use. They are optimized to increase clinical efficiency and reduce complications through precision energy delivery, reliable tissue effect profiles, and comprehensive safety interlocks.\n\nThe following Contract Line Items are being considered:\n\nContract Line Item#\nBrand\nPart Number\nDescription\n0001\nERBE USA INC. \n\nVIOÂ® 3\n0001A\nERBE USA INC.\n10160-000\nVIOÂ® Electrosurgical unit\n0001B\nERBE USA INC.\n20189-353 \nTwo-pedal foot switch, VIOÂ® 3 ReModeÂ®, bracket, middle piece\n0001C\nERBE USA INC.\n20188-350\nOne-pedal foot switch, VIOÂ® 3 ReModeÂ®\n0001D\nERBE USA INC.\n20180-000\nVIOÂ® CART System carrier for VIOÂ®\n0001E\nERBE USA INC.\n20180-010\nWire basket, 339 x 205 x 155 / 100 mm\n0002\nERBE USA INC. \n\nAttachment Sets\n0002A\nERBE USA INC.\n20180-140\nFastening set for VIOÂ® 3 on VIOÂ® Cart\n0002B\nERBE USA INC.\n20180-143\nFastening set VIOÂ® 3 for APCÂ® 3 on boom mount\n0002C\nERBE USA INC.\n20180-144\nFastening set VIOÂ® 3 for APCÂ® 3 on ERBEJETÂ® 2\n0003\nERBE USA INC.\n\nInstrument cables from Erbe\n0003A\nERBE USA INC.\n20192-133\nMonopolar cable MO 3Pin; MIS OD 4mm; L 4.5m\n0003B\nERBE USA INC. \n20192-134\nMonopolar cable MO 3Pin; OD 4.5mm pin; L 4.5m\n0003C\nERBE USA INC.\n20192-135\nMonopolar cable MO 3Pin; OD 3mm socket; L 4.5m\n0003D\nERBE USA INC.\n20196-064\nBipolar cable BI 2Pin28; ang.; forceps; L 4.5m\n0003E\nERBE USA INC.\n20196-067\nBipolar cable BI 2Pin28; grasp. forceps; L 4.5m\n0003F\nERBE USA INC.\n20196-127\nBipolar cable BI 2Pin28; forceps 2Pin; L 4m\n0003G\nERBE USA INC.\n21196-115\nBipolar Conecting Cable; MF-U Olympus Resectoscope; L 4.5m\n0003H\nERBE USA INC. \n21196-118\nBipolar Connecting Cable; MF-U Storz Resectoscope; L 4.5m\n0003I\nERBE USA INC.\n21196-119\nBipolar Connecting Cable; MF-U Wolf Resectoscope; L 4.5m\n0004\nERBE USA INC.\n\nVIOÂ® 300 D\n0004A\nERBE USA INC.\n10140-100\nVIOÂ® 300 D Electrosurgical Unit 120V/60HZ UL , Software Version 2.X Constant Voltage\n0004B\nERBE USA INC.\n20189-305\nVIOÂ® two pedal footswitch w/ReModeÂ® w/Bracket (Remode Feature Allows Changing between Preset Programs)\n0004C\nERBE USA INC.\n20180 131\nConnection Adapter, Cryo Probe to Erbokryo CA\n0004D\nERBE USA INC.\n20183-053\nAdapter for BICAP or Gold Probe \n0004E\nERBE USA INC.\n20193-084\nNESSYÂ® Omega monitoring pad with cable (50 per case)\n0004F\nERBE USA INC.\n20180-000\nVIOÂ® Cart with footswitch holder, cable wrap and 1 tank fixation kit\n0004G\nERBE USA INC.\n20180-010\nVIOÂ® Cart wire basket\n0004H\nERBE USA INC.\n20180-131\nVIOÂ®/APCÂ® 2 to VIOÂ® Cart fastening set (with grounding cable)\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide ErbeÂ® VIO 3 Electrosurgical Units (ESUs); Argon-Enhanced Coagulation system or equal as listed above which meet all the following salient characteristics: Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Products quoted in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.\n\nApply the following SCs to CLIN s 0001-0004\n \n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC1\nMust be cleared by the U.S. Food and Drug Administration (FDA) as an electrosurgical generator with compatible argon-enhanced coagulation capability for cutting and coagulation of tissue in general, laparoscopic, and endoscopic surgery, including hemostasis and devitalization of soft tissues.\nLiterature Review\nSC2\nMust provide a centralized color touchscreen user interface that allows the operator to select, monitor, and adjust at minimum: Electrosurgical mode (e.g., monopolar cut, monopolar coag, bipolar, argon coagulation); Output power settings (watts); Application-relevant parameters (e.g., argon gas flow and effect settings for argon-enhanced coagulation); and Treatment or activation time (timer or activation counters).\nLiterature Review\nSC3\nMust be compatible with a range of monopolar and bipolar instruments, as well as compatible argon probes/catheters and applicators, in various working lengths suitable for open and endoscopic procedures.\nLiterature Review\nSC4\nMust consist of modular argon plasma capability with adjustable gas flow rates (0.1 to 6 L/min) and multiple APC waveforms (precise, pulsed, forced) for non-contact surface coagulation, enabling effective hemostasis and tissue ablation in gastrointestinal, respiratory, and other anatomical applications.\nLiterature Review\nSC5\nMust have advanced neutral electrode monitoring (such as NESSY technology) that dynamically tracks patient impedance levels and return electrode contact/orientation, along with proprietary spark recognition and control algorithms to minimize carbonization, tissue adhesion, and unintended thermal injury.\nLiterature Review\nSC6\nMust consist of compact design with multiple socket configurations (monopolar, bipolar, universal connections) accommodating international and manufacturer-specific instrument standards, wireless and wired footswitch options, and compatibility with smoke evacuation and insufflation systems for streamlined OR workflow.\nLiterature Review\nSC7\nMust include a minimum one year manufacturer warranty covering parts and labor, with availability of installation, user training, and ongoing service support programs.\nLiterature Review\n\nEvaluation Sub-factors\n\n1. Design: Design features and function will be evaluated based on, but not limited to, the following: \nCentralized touchscreen user interface: Large, color touchscreen with logical application-oriented men for quick selection and confirmation of modes to include APC settings. \nMulti-instrument connectivity and APC integration to include argon probes and APC hand pieces. \nProcedure and instrument-based presents: Recognizes instrument and procedure-specific programs that automatically load parameters and standardizes set-up. \n\n2. Performance: Performance capabilities, features and functions of the device offered will be evaluated for technical performance, reliability, and clinical effectiveness. These elements include, but are not limited to:\nHigh dynamic power delivery: Power supply is able to maintain stable output under variable loads and APC modes. \nRapid response measurement rate: High measurement of frequency of target tissue effects across different tissue types and cutting speeds supporting argon-assisted coagulation lines.  \nMulti-modality support: Concurrent support for monopolar, bipolar, and hybrid/argon-assisted applications across platforms without swapping generators during an on-going procedure. \n\n3. Safety: All features and functions of the equipment shall be evaluated for the ability to be safely installed, secured, and protected against harm; physical or any form. These elements include, but are not limited to:\nRegulatory compliance and clearances: FDA 510(K) clearance status.\nSystems and operational features safety related to electrical and argon-gas.\nWarning and alarms capability\n\n4. Quality/Construction/Training:  Elements will include, but are not limited to:\nRobust construction and medical-grade standards.\nPower consumption, backup power, and energy efficiency.\nTerms and conditions of installation, training, and service agreement programs.\nExpected life cycle to include sanitation, infection control, and maintenance.\n\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\n \nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nIf applicable, vendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nSAM Unique Entity Identifier (UEI) / CAGE Code\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf the distributor, provide manufacturer s full name, business size and address.\n \nCountry of Origin designation for all products.\n\n Ability to provide uninterrupted supply of products on a national scale.\n\n Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n \n Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\n Authorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.\n\nContractors submitting capability statements in response to this RFI must specifically address the questions outlined above. Generic capability statements that do not directly pertain to this RFI will not be considered. Additionally, links requesting capability statements or further information will not be accessed. All responses must be submitted as an actual file attachment.","text":"DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified Electrosurgical Units (ESUs); Argon-Enhanced Coagulation product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.\n\nThe Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Request for Information (RFI) in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. The period of performance will consist of a base of 12-months with four 12-month option periods from the date of award.\nThe SAC in conjunction with VHA is seeking a qualified source to manufacture Electrosurgical Units (ESUs); Argon-Enhanced Coagulation on an agency wide basis. VA intends to award a Brand Name or Equal (BNOE) single award Requirements contract for this requirement IAW with FAR 16.503. Vendors will be required to deliver Electrosurgical Units (ESUs); Argon-Enhanced Coagulation to VA medical centers and facilities throughout the United States.\nThe anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112 Surgical and Medical Instrument Manufacturing and the associated size standard is 1,000 employees. The FAR Provision found at 52.204-7 requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nElectrosurgical Units (ESUs); Argon-Enhanced Coagulation (AEC) are advanced, energy based surgical systems used to perform precise tissue coagulation and devitalization across Veterans Affairs Medical Centers (VAMCs), particularly in operating rooms (OR), procedural suites, and endoscopy units. They deliver radiofrequency (RF) energy through specialized electrodes while directing a controlled flow of inert argon gas to create a conductive plasma at the tissue surface. This results in uniform, noncontact coagulation with minimal tissue penetration, improved visualization, and reduced bleeding. ESUs with AEC are designed to enhance surgical efficiency, improve hemostasis, and support consistent, replicable outcomes across a range of open, laparoscopic, and endoscopic procedures.\n\nThese systems provide real-time, automated control of power delivery, argon flow, and activation mode, with integrated safety monitoring and configurable presets for procedure-specific use. They are optimized to increase clinical efficiency and reduce complications through precision energy delivery, reliable tissue effect profiles, and comprehensive safety interlocks.\n\nThe following Contract Line Items are being considered:\n\nContract Line Item#\nBrand\nPart Number\nDescription\n0001\nERBE USA INC.\n\nVIOÂ® 3\n0001A\nERBE USA INC.\n10160-000\nVIOÂ® Electrosurgical unit\n0001B\nERBE USA INC.\n20189-353\nTwo-pedal foot switch, VIOÂ® 3 ReModeÂ®, bracket, middle piece\n0001C\nERBE USA INC.\n20188-350\nOne-pedal foot switch, VIOÂ® 3 ReModeÂ®\n0001D\nERBE USA INC.\n20180-000\nVIOÂ® CART System carrier for VIOÂ®\n0001E\nERBE USA INC.\n20180-010\nWire basket, 339 x 205 x 155 / 100 mm\n0002\nERBE USA INC.\n\nAttachment Sets\n0002A\nERBE USA INC.\n20180-140\nFastening set for VIOÂ® 3 on VIOÂ® Cart\n0002B\nERBE USA INC.\n20180-143\nFastening set VIOÂ® 3 for APCÂ® 3 on boom mount\n0002C\nERBE USA INC.\n20180-144\nFastening set VIOÂ® 3 for APCÂ® 3 on ERBEJETÂ® 2\n0003\nERBE USA INC.\n\nInstrument cables from Erbe\n0003A\nERBE USA INC.\n20192-133\nMonopolar cable MO 3Pin; MIS OD 4mm; L 4.5m\n0003B\nERBE USA INC.\n20192-134\nMonopolar cable MO 3Pin; OD 4.5mm pin; L 4.5m\n0003C\nERBE USA INC.\n20192-135\nMonopolar cable MO 3Pin; OD 3mm socket; L 4.5m\n0003D\nERBE USA INC.\n20196-064\nBipolar cable BI 2Pin28; ang.; forceps; L 4.5m\n0003E\nERBE USA INC.\n20196-067\nBipolar cable BI 2Pin28; grasp. forceps; L 4.5m\n0003F\nERBE USA INC.\n20196-127\nBipolar cable BI 2Pin28; forceps 2Pin; L 4m\n0003G\nERBE USA INC.\n21196-115\nBipolar Conecting Cable; MF-U Olympus Resectoscope; L 4.5m\n0003H\nERBE USA INC.\n21196-118\nBipolar Connecting Cable; MF-U Storz Resectoscope; L 4.5m\n0003I\nERBE USA INC.\n21196-119\nBipolar Connecting Cable; MF-U Wolf Resectoscope; L 4.5m\n0004\nERBE USA INC.\n\nVIOÂ® 300 D\n0004A\nERBE USA INC.\n10140-100\nVIOÂ® 300 D Electrosurgical Unit 120V/60HZ UL , Software Version 2.X Constant Voltage\n0004B\nERBE USA INC.\n20189-305\nVIOÂ® two pedal footswitch w/ReModeÂ® w/Bracket (Remode Feature Allows Changing between Preset Programs)\n0004C\nERBE USA INC.\n20180 131\nConnection Adapter, Cryo Probe to Erbokryo CA\n0004D\nERBE USA INC.\n20183-053\nAdapter for BICAP or Gold Probe\n0004E\nERBE USA INC.\n20193-084\nNESSYÂ® Omega monitoring pad with cable (50 per case)\n0004F\nERBE USA INC.\n20180-000\nVIOÂ® Cart with footswitch holder, cable wrap and 1 tank fixation kit\n0004G\nERBE USA INC.\n20180-010\nVIOÂ® Cart wire basket\n0004H\nERBE USA INC.\n20180-131\nVIOÂ®/APCÂ® 2 to VIOÂ® Cart fastening set (with grounding cable)\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide ErbeÂ® VIO 3 Electrosurgical Units (ESUs); Argon-Enhanced Coagulation system or equal as listed above which meet all the following salient characteristics: Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Products quoted in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.\n\nApply the following SCs to CLIN s 0001-0004\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC1\nMust be cleared by the U.S. Food and Drug Administration (FDA) as an electrosurgical generator with compatible argon-enhanced coagulation capability for cutting and coagulation of tissue in general, laparoscopic, and endoscopic surgery, including hemostasis and devitalization of soft tissues.\nLiterature Review\nSC2\nMust provide a centralized color touchscreen user interface that allows the operator to select, monitor, and adjust at minimum: Electrosurgical mode (e.g., monopolar cut, monopolar coag, bipolar, argon coagulation); Output power settings (watts); Application-relevant parameters (e.g., argon gas flow and effect settings for argon-enhanced coagulation); and Treatment or activation time (timer or activation counters).\nLiterature Review\nSC3\nMust be compatible with a range of monopolar and bipolar instruments, as well as compatible argon probes/catheters and applicators, in various working lengths suitable for open and endoscopic procedures.\nLiterature Review\nSC4\nMust consist of modular argon plasma capability with adjustable gas flow rates (0.1 to 6 L/min) and multiple APC waveforms (precise, pulsed, forced) for non-contact surface coagulation, enabling effective hemostasis and tissue ablation in gastrointestinal, respiratory, and other anatomical applications.\nLiterature Review\nSC5\nMust have advanced neutral electrode monitoring (such as NESSY technology) that dynamically tracks patient impedance levels and return electrode contact/orientation, along with proprietary spark recognition and control algorithms to minimize carbonization, tissue adhesion, and unintended thermal injury.\nLiterature Review\nSC6\nMust consist of compact design with multiple socket configurations (monopolar, bipolar, universal connections) accommodating international and manufacturer-specific instrument standards, wireless and wired footswitch options, and compatibility with smoke evacuation and insufflation systems for streamlined OR workflow.\nLiterature Review\nSC7\nMust include a minimum one year manufacturer warranty covering parts and labor, with availability of installation, user training, and ongoing service support programs.\nLiterature Review\n\nEvaluation Sub-factors\n\n1. Design: Design features and function will be evaluated based on, but not limited to, the following:\nCentralized touchscreen user interface: Large, color touchscreen with logical application-oriented men for quick selection and confirmation of modes to include APC settings.\nMulti-instrument connectivity and APC integration to include argon probes and APC hand pieces.\nProcedure and instrument-based presents: Recognizes instrument and procedure-specific programs that automatically load parameters and standardizes set-up.\n\n2. Performance: Performance capabilities, features and functions of the device offered will be evaluated for technical performance, reliability, and clinical effectiveness. These elements include, but are not limited to:\nHigh dynamic power delivery: Power supply is able to maintain stable output under variable loads and APC modes.\nRapid response measurement rate: High measurement of frequency of target tissue effects across different tissue types and cutting speeds supporting argon-assisted coagulation lines.\nMulti-modality support: Concurrent support for monopolar, bipolar, and hybrid/argon-assisted applications across platforms without swapping generators during an on-going procedure.\n\n3. Safety: All features and functions of the equipment shall be evaluated for the ability to be safely installed, secured, and protected against harm; physical or any form. These elements include, but are not limited to:\nRegulatory compliance and clearances: FDA 510(K) clearance status.\nSystems and operational features safety related to electrical and argon-gas.\nWarning and alarms capability\n\n4. Quality/Construction/Training: Elements will include, but are not limited to:\nRobust construction and medical-grade standards.\nPower consumption, backup power, and energy efficiency.\nTerms and conditions of installation, training, and service agreement programs.\nExpected life cycle to include sanitation, infection control, and maintenance.\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\n\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nIf applicable, vendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nSAM Unique Entity Identifier (UEI) / CAGE Code\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf the distributor, provide manufacturer s full name, business size and address.\n\nCountry of Origin designation for all products.\n\nAbility to provide uninterrupted supply of products on a national scale.\n\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.\n\nContractors submitting capability statements in response to this RFI must specifically address the questions outlined above. Generic capability statements that do not directly pertain to this RFI will not be considered. Additionally, links requesting capability statements or further information will not be accessed. All responses must be submitted as an actual file attachment.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10G26Q0035","place_of_performance":{"street":"Enterprise-wide","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6515"}],"due_at":"2026-01-27T04:59:00Z","due_date":"2026-01-26","closes_at":"2026-01-27T04:59:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-16T03:27:28.974362Z","principal_notice_id":"403af7f4043348c3bb4c645238dfc252","description":{"text":"DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified Electrosurgical Units (ESUs); Argon-Enhanced Coagulation product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.\n\nThe Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Request for Information (RFI) in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. The period of performance will consist of a base of 12-months with four 12-month option periods from the date of award.\nThe SAC in conjunction with VHA is seeking a qualified source to manufacture Electrosurgical Units (ESUs); Argon-Enhanced Coagulation on an agency wide basis. VA intends to award a Brand Name or Equal (BNOE) single award Requirements contract for this requirement IAW with FAR 16.503. Vendors will be required to deliver Electrosurgical Units (ESUs); Argon-Enhanced Coagulation to VA medical centers and facilities throughout the United States.\nThe anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112 Surgical and Medical Instrument Manufacturing and the associated size standard is 1,000 employees. The FAR Provision found at 52.204-7 requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nElectrosurgical Units (ESUs); Argon-Enhanced Coagulation (AEC) are advanced, energy based surgical systems used to perform precise tissue coagulation and devitalization across Veterans Affairs Medical Centers (VAMCs), particularly in operating rooms (OR), procedural suites, and endoscopy units. They deliver radiofrequency (RF) energy through specialized electrodes while directing a controlled flow of inert argon gas to create a conductive plasma at the tissue surface. This results in uniform, noncontact coagulation with minimal tissue penetration, improved visualization, and reduced bleeding. ESUs with AEC are designed to enhance surgical efficiency, improve hemostasis, and support consistent, replicable outcomes across a range of open, laparoscopic, and endoscopic procedures.\n\nThese systems provide real-time, automated control of power delivery, argon flow, and activation mode, with integrated safety monitoring and configurable presets for procedure-specific use. They are optimized to increase clinical efficiency and reduce complications through precision energy delivery, reliable tissue effect profiles, and comprehensive safety interlocks.\n\nThe following Contract Line Items are being considered:\n\nContract Line Item#\nBrand\nPart Number\nDescription\n0001\nERBE USA INC.\n\nVIOÂ® 3\n0001A\nERBE USA INC.\n10160-000\nVIOÂ® Electrosurgical unit\n0001B\nERBE USA INC.\n20189-353\nTwo-pedal foot switch, VIOÂ® 3 ReModeÂ®, bracket, middle piece\n0001C\nERBE USA INC.\n20188-350\nOne-pedal foot switch, VIOÂ® 3 ReModeÂ®\n0001D\nERBE USA INC.\n20180-000\nVIOÂ® CART System carrier for VIOÂ®\n0001E\nERBE USA INC.\n20180-010\nWire basket, 339 x 205 x 155 / 100 mm\n0002\nERBE USA INC.\n\nAttachment Sets\n0002A\nERBE USA INC.\n20180-140\nFastening set for VIOÂ® 3 on VIOÂ® Cart\n0002B\nERBE USA INC.\n20180-143\nFastening set VIOÂ® 3 for APCÂ® 3 on boom mount\n0002C\nERBE USA INC.\n20180-144\nFastening set VIOÂ® 3 for APCÂ® 3 on ERBEJETÂ® 2\n0003\nERBE USA INC.\n\nInstrument cables from Erbe\n0003A\nERBE USA INC.\n20192-133\nMonopolar cable MO 3Pin; MIS OD 4mm; L 4.5m\n0003B\nERBE USA INC.\n20192-134\nMonopolar cable MO 3Pin; OD 4.5mm pin; L 4.5m\n0003C\nERBE USA INC.\n20192-135\nMonopolar cable MO 3Pin; OD 3mm socket; L 4.5m\n0003D\nERBE USA INC.\n20196-064\nBipolar cable BI 2Pin28; ang.; forceps; L 4.5m\n0003E\nERBE USA INC.\n20196-067\nBipolar cable BI 2Pin28; grasp. forceps; L 4.5m\n0003F\nERBE USA INC.\n20196-127\nBipolar cable BI 2Pin28; forceps 2Pin; L 4m\n0003G\nERBE USA INC.\n21196-115\nBipolar Conecting Cable; MF-U Olympus Resectoscope; L 4.5m\n0003H\nERBE USA INC.\n21196-118\nBipolar Connecting Cable; MF-U Storz Resectoscope; L 4.5m\n0003I\nERBE USA INC.\n21196-119\nBipolar Connecting Cable; MF-U Wolf Resectoscope; L 4.5m\n0004\nERBE USA INC.\n\nVIOÂ® 300 D\n0004A\nERBE USA INC.\n10140-100\nVIOÂ® 300 D Electrosurgical Unit 120V/60HZ UL , Software Version 2.X Constant Voltage\n0004B\nERBE USA INC.\n20189-305\nVIOÂ® two pedal footswitch w/ReModeÂ® w/Bracket (Remode Feature Allows Changing between Preset Programs)\n0004C\nERBE USA INC.\n20180 131\nConnection Adapter, Cryo Probe to Erbokryo CA\n0004D\nERBE USA INC.\n20183-053\nAdapter for BICAP or Gold Probe\n0004E\nERBE USA INC.\n20193-084\nNESSYÂ® Omega monitoring pad with cable (50 per case)\n0004F\nERBE USA INC.\n20180-000\nVIOÂ® Cart with footswitch holder, cable wrap and 1 tank fixation kit\n0004G\nERBE USA INC.\n20180-010\nVIOÂ® Cart wire basket\n0004H\nERBE USA INC.\n20180-131\nVIOÂ®/APCÂ® 2 to VIOÂ® Cart fastening set (with grounding cable)\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide ErbeÂ® VIO 3 Electrosurgical Units (ESUs); Argon-Enhanced Coagulation system or equal as listed above which meet all the following salient characteristics: Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Products quoted in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.\n\nApply the following SCs to CLIN s 0001-0004\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC1\nMust be cleared by the U.S. Food and Drug Administration (FDA) as an electrosurgical generator with compatible argon-enhanced coagulation capability for cutting and coagulation of tissue in general, laparoscopic, and endoscopic surgery, including hemostasis and devitalization of soft tissues.\nLiterature Review\nSC2\nMust provide a centralized color touchscreen user interface that allows the operator to select, monitor, and adjust at minimum: Electrosurgical mode (e.g., monopolar cut, monopolar coag, bipolar, argon coagulation); Output power settings (watts); Application-relevant parameters (e.g., argon gas flow and effect settings for argon-enhanced coagulation); and Treatment or activation time (timer or activation counters).\nLiterature Review\nSC3\nMust be compatible with a range of monopolar and bipolar instruments, as well as compatible argon probes/catheters and applicators, in various working lengths suitable for open and endoscopic procedures.\nLiterature Review\nSC4\nMust consist of modular argon plasma capability with adjustable gas flow rates (0.1 to 6 L/min) and multiple APC waveforms (precise, pulsed, forced) for non-contact surface coagulation, enabling effective hemostasis and tissue ablation in gastrointestinal, respiratory, and other anatomical applications.\nLiterature Review\nSC5\nMust have advanced neutral electrode monitoring (such as NESSY technology) that dynamically tracks patient impedance levels and return electrode contact/orientation, along with proprietary spark recognition and control algorithms to minimize carbonization, tissue adhesion, and unintended thermal injury.\nLiterature Review\nSC6\nMust consist of compact design with multiple socket configurations (monopolar, bipolar, universal connections) accommodating international and manufacturer-specific instrument standards, wireless and wired footswitch options, and compatibility with smoke evacuation and insufflation systems for streamlined OR workflow.\nLiterature Review\nSC7\nMust include a minimum one year manufacturer warranty covering parts and labor, with availability of installation, user training, and ongoing service support programs.\nLiterature Review\n\nEvaluation Sub-factors\n\n1. Design: Design features and function will be evaluated based on, but not limited to, the following:\nCentralized touchscreen user interface: Large, color touchscreen with logical application-oriented men for quick selection and confirmation of modes to include APC settings.\nMulti-instrument connectivity and APC integration to include argon probes and APC hand pieces.\nProcedure and instrument-based presents: Recognizes instrument and procedure-specific programs that automatically load parameters and standardizes set-up.\n\n2. Performance: Performance capabilities, features and functions of the device offered will be evaluated for technical performance, reliability, and clinical effectiveness. These elements include, but are not limited to:\nHigh dynamic power delivery: Power supply is able to maintain stable output under variable loads and APC modes.\nRapid response measurement rate: High measurement of frequency of target tissue effects across different tissue types and cutting speeds supporting argon-assisted coagulation lines.\nMulti-modality support: Concurrent support for monopolar, bipolar, and hybrid/argon-assisted applications across platforms without swapping generators during an on-going procedure.\n\n3. Safety: All features and functions of the equipment shall be evaluated for the ability to be safely installed, secured, and protected against harm; physical or any form. These elements include, but are not limited to:\nRegulatory compliance and clearances: FDA 510(K) clearance status.\nSystems and operational features safety related to electrical and argon-gas.\nWarning and alarms capability\n\n4. Quality/Construction/Training: Elements will include, but are not limited to:\nRobust construction and medical-grade standards.\nPower consumption, backup power, and energy efficiency.\nTerms and conditions of installation, training, and service agreement programs.\nExpected life cycle to include sanitation, infection control, and maintenance.\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\n\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nIf applicable, vendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nSAM Unique Entity Identifier (UEI) / CAGE Code\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf the distributor, provide manufacturer s full name, business size and address.\n\nCountry of Origin designation for all products.\n\nAbility to provide uninterrupted supply of products on a national scale.\n\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.\n\nContractors submitting capability statements in response to this RFI must specifically address the questions outlined above. Generic capability statements that do not directly pertain to this RFI will not be considered. Additionally, links requesting capability statements or further information will not be accessed. All responses must be submitted as an actual file attachment.","html":"DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified Electrosurgical Units (ESUs); Argon-Enhanced Coagulation product line as a candidate for a VA-wide (otherwise referred to as  national ) single Requirements contract award.  \n\nThe Department of Veterans Affairs  (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Request for Information (RFI) in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. The period of performance will consist of a base of 12-months with four 12-month option periods from the date of award. \nThe SAC in conjunction with VHA is seeking a qualified source to manufacture Electrosurgical Units (ESUs); Argon-Enhanced Coagulation on an agency wide basis. VA intends to award a Brand Name or Equal (BNOE) single award Requirements contract for this requirement IAW with FAR 16.503. Vendors will be required to deliver Electrosurgical Units (ESUs); Argon-Enhanced Coagulation to VA medical centers and facilities throughout the United States.  \nThe anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339112 Surgical and Medical Instrument Manufacturing and the associated size standard is 1,000 employees. The FAR Provision found at 52.204-7 requires that  All interested Offerors must be registered in SAM prior to submitting an offer or proposal.  You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nElectrosurgical Units (ESUs); Argon-Enhanced Coagulation (AEC) are advanced, energy based surgical systems used to perform precise tissue coagulation and devitalization across Veterans Affairs Medical Centers (VAMCs), particularly in operating rooms (OR), procedural suites, and endoscopy units. They deliver radiofrequency (RF) energy through specialized electrodes while directing a controlled flow of inert argon gas to create a conductive plasma at the tissue surface. This results in uniform, noncontact coagulation with minimal tissue penetration, improved visualization, and reduced bleeding. ESUs with AEC are designed to enhance surgical efficiency, improve hemostasis, and support consistent, replicable outcomes across a range of open, laparoscopic, and endoscopic procedures.\n\nThese systems provide real-time, automated control of power delivery, argon flow, and activation mode, with integrated safety monitoring and configurable presets for procedure-specific use. They are optimized to increase clinical efficiency and reduce complications through precision energy delivery, reliable tissue effect profiles, and comprehensive safety interlocks.\n\nThe following Contract Line Items are being considered:\n\nContract Line Item#\nBrand\nPart Number\nDescription\n0001\nERBE USA INC. \n\nVIOÂ® 3\n0001A\nERBE USA INC.\n10160-000\nVIOÂ® Electrosurgical unit\n0001B\nERBE USA INC.\n20189-353 \nTwo-pedal foot switch, VIOÂ® 3 ReModeÂ®, bracket, middle piece\n0001C\nERBE USA INC.\n20188-350\nOne-pedal foot switch, VIOÂ® 3 ReModeÂ®\n0001D\nERBE USA INC.\n20180-000\nVIOÂ® CART System carrier for VIOÂ®\n0001E\nERBE USA INC.\n20180-010\nWire basket, 339 x 205 x 155 / 100 mm\n0002\nERBE USA INC. \n\nAttachment Sets\n0002A\nERBE USA INC.\n20180-140\nFastening set for VIOÂ® 3 on VIOÂ® Cart\n0002B\nERBE USA INC.\n20180-143\nFastening set VIOÂ® 3 for APCÂ® 3 on boom mount\n0002C\nERBE USA INC.\n20180-144\nFastening set VIOÂ® 3 for APCÂ® 3 on ERBEJETÂ® 2\n0003\nERBE USA INC.\n\nInstrument cables from Erbe\n0003A\nERBE USA INC.\n20192-133\nMonopolar cable MO 3Pin; MIS OD 4mm; L 4.5m\n0003B\nERBE USA INC. \n20192-134\nMonopolar cable MO 3Pin; OD 4.5mm pin; L 4.5m\n0003C\nERBE USA INC.\n20192-135\nMonopolar cable MO 3Pin; OD 3mm socket; L 4.5m\n0003D\nERBE USA INC.\n20196-064\nBipolar cable BI 2Pin28; ang.; forceps; L 4.5m\n0003E\nERBE USA INC.\n20196-067\nBipolar cable BI 2Pin28; grasp. forceps; L 4.5m\n0003F\nERBE USA INC.\n20196-127\nBipolar cable BI 2Pin28; forceps 2Pin; L 4m\n0003G\nERBE USA INC.\n21196-115\nBipolar Conecting Cable; MF-U Olympus Resectoscope; L 4.5m\n0003H\nERBE USA INC. \n21196-118\nBipolar Connecting Cable; MF-U Storz Resectoscope; L 4.5m\n0003I\nERBE USA INC.\n21196-119\nBipolar Connecting Cable; MF-U Wolf Resectoscope; L 4.5m\n0004\nERBE USA INC.\n\nVIOÂ® 300 D\n0004A\nERBE USA INC.\n10140-100\nVIOÂ® 300 D Electrosurgical Unit 120V/60HZ UL , Software Version 2.X Constant Voltage\n0004B\nERBE USA INC.\n20189-305\nVIOÂ® two pedal footswitch w/ReModeÂ® w/Bracket (Remode Feature Allows Changing between Preset Programs)\n0004C\nERBE USA INC.\n20180 131\nConnection Adapter, Cryo Probe to Erbokryo CA\n0004D\nERBE USA INC.\n20183-053\nAdapter for BICAP or Gold Probe \n0004E\nERBE USA INC.\n20193-084\nNESSYÂ® Omega monitoring pad with cable (50 per case)\n0004F\nERBE USA INC.\n20180-000\nVIOÂ® Cart with footswitch holder, cable wrap and 1 tank fixation kit\n0004G\nERBE USA INC.\n20180-010\nVIOÂ® Cart wire basket\n0004H\nERBE USA INC.\n20180-131\nVIOÂ®/APCÂ® 2 to VIOÂ® Cart fastening set (with grounding cable)\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide ErbeÂ® VIO 3 Electrosurgical Units (ESUs); Argon-Enhanced Coagulation system or equal as listed above which meet all the following salient characteristics: Vendors may quote any product solution or configuration so long as they meet the salient characteristics. Products quoted in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may quote any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.\n\nApply the following SCs to CLIN s 0001-0004\n \n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC1\nMust be cleared by the U.S. Food and Drug Administration (FDA) as an electrosurgical generator with compatible argon-enhanced coagulation capability for cutting and coagulation of tissue in general, laparoscopic, and endoscopic surgery, including hemostasis and devitalization of soft tissues.\nLiterature Review\nSC2\nMust provide a centralized color touchscreen user interface that allows the operator to select, monitor, and adjust at minimum: Electrosurgical mode (e.g., monopolar cut, monopolar coag, bipolar, argon coagulation); Output power settings (watts); Application-relevant parameters (e.g., argon gas flow and effect settings for argon-enhanced coagulation); and Treatment or activation time (timer or activation counters).\nLiterature Review\nSC3\nMust be compatible with a range of monopolar and bipolar instruments, as well as compatible argon probes/catheters and applicators, in various working lengths suitable for open and endoscopic procedures.\nLiterature Review\nSC4\nMust consist of modular argon plasma capability with adjustable gas flow rates (0.1 to 6 L/min) and multiple APC waveforms (precise, pulsed, forced) for non-contact surface coagulation, enabling effective hemostasis and tissue ablation in gastrointestinal, respiratory, and other anatomical applications.\nLiterature Review\nSC5\nMust have advanced neutral electrode monitoring (such as NESSY technology) that dynamically tracks patient impedance levels and return electrode contact/orientation, along with proprietary spark recognition and control algorithms to minimize carbonization, tissue adhesion, and unintended thermal injury.\nLiterature Review\nSC6\nMust consist of compact design with multiple socket configurations (monopolar, bipolar, universal connections) accommodating international and manufacturer-specific instrument standards, wireless and wired footswitch options, and compatibility with smoke evacuation and insufflation systems for streamlined OR workflow.\nLiterature Review\nSC7\nMust include a minimum one year manufacturer warranty covering parts and labor, with availability of installation, user training, and ongoing service support programs.\nLiterature Review\n\nEvaluation Sub-factors\n\n1. Design: Design features and function will be evaluated based on, but not limited to, the following: \nCentralized touchscreen user interface: Large, color touchscreen with logical application-oriented men for quick selection and confirmation of modes to include APC settings. \nMulti-instrument connectivity and APC integration to include argon probes and APC hand pieces. \nProcedure and instrument-based presents: Recognizes instrument and procedure-specific programs that automatically load parameters and standardizes set-up. \n\n2. Performance: Performance capabilities, features and functions of the device offered will be evaluated for technical performance, reliability, and clinical effectiveness. These elements include, but are not limited to:\nHigh dynamic power delivery: Power supply is able to maintain stable output under variable loads and APC modes. \nRapid response measurement rate: High measurement of frequency of target tissue effects across different tissue types and cutting speeds supporting argon-assisted coagulation lines.  \nMulti-modality support: Concurrent support for monopolar, bipolar, and hybrid/argon-assisted applications across platforms without swapping generators during an on-going procedure. \n\n3. Safety: All features and functions of the equipment shall be evaluated for the ability to be safely installed, secured, and protected against harm; physical or any form. These elements include, but are not limited to:\nRegulatory compliance and clearances: FDA 510(K) clearance status.\nSystems and operational features safety related to electrical and argon-gas.\nWarning and alarms capability\n\n4. Quality/Construction/Training:  Elements will include, but are not limited to:\nRobust construction and medical-grade standards.\nPower consumption, backup power, and energy efficiency.\nTerms and conditions of installation, training, and service agreement programs.\nExpected life cycle to include sanitation, infection control, and maintenance.\n\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\n \nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nIf applicable, vendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nSAM Unique Entity Identifier (UEI) / CAGE Code\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf the distributor, provide manufacturer s full name, business size and address.\n \nCountry of Origin designation for all products.\n\n Ability to provide uninterrupted supply of products on a national scale.\n\n Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n \n Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\n Authorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.\n\nContractors submitting capability statements in response to this RFI must specifically address the questions outlined above. Generic capability statements that do not directly pertain to this RFI will not be considered. Additionally, links requesting capability statements or further information will not be accessed. All responses must be submitted as an actual file attachment.","origin":"detail"},"contacts":[{"fax":"Hosea Berkley","name":"Daleta Coles","role":"primary","email":"daleta.coles@va.gov","phone":"Contracting Officer","title":"Contract Specialist"}],"place_of_performance":{"street":"Enterprise-wide","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"naics_codes":["339112"],"award":{"awardee":{}},"attachments":[{"resource_id":"ca46999e6d9b47cc900662ddecf30574","name":"36C10G26Q0035.docx","kind":"file","mime_type":".docx","size_bytes":42853,"posted_at":"2026-01-12T15:28:37.998Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ca46999e6d9b47cc900662ddecf30574/download","mirrored":false}],"awards":[],"related":[{"key":"36C10G27R0002","latest_notice_id":"f16ea5b6f90d4b3e903edd9b27a5c3aa","title":"6515--Patient Lifts and Slings for In Home Use","solicitation_number":"36C10G27R0002","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":4,"due_at":"2026-12-15T17:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"339113","psc":"6515","set_aside":"SBP","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open":[{"key":"W911S227U0200","latest_notice_id":"153aef7d00e740188276deb8422a2297","title":"Automated External Defibrillator (AED)","solicitation_number":"W911S227U0200","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-11-26T20:15:00Z","due_date":"2026-11-26","closes_at":"2026-11-26T20:15:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339112","psc":"6515","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"36C10X27Q0025","latest_notice_id":"8c404062fbbc4212bb93120ad204ee50","title":"6515--NX EQ Microscope, Light, Operating, Hand/Plastic Surgery (VA-27-00017958)","solicitation_number":"36C10X27Q0025","notice_type":"r","first_type":"r","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"339112","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-19T00:57:17.217280Z"},{"key":"SPE2DS27T2443","latest_notice_id":"8f83cd5d4eb6487083e3a8ace6f5842d","title":"65--TEST KIT,MICRO SAMPLE","solicitation_number":"SPE2DS27T2443","notice_type":"k","first_type":"k","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":1,"due_at":null,"due_date":"2026-11-30","closes_at":"2026-12-01T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97AS","sub_name":"DEFENSE LOGISTICS AGENCY","office_key":"o-SPE2DS","office_name":"DLA TROOP SUPPORT","naics":"339112","psc":"65","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"SAMPLE: LINE 0001 QTY 4 UI EA DELIVER TO: AMC BAMC FSH - MM BY:","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"}],"similar_open_total":15,"indexable":false}