{"canonical":"https://sealedbidder.com/opportunities/36c10g26q0006","key":"36C10G26Q0006","url":"https://sealedbidder.com/opportunities/36c10g26q0006","title":"6515--NX EQ Lifts: Patient Transfer: Floor Based: Bariatric","solicitation_number":"36C10G26Q0006","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-11-04T23:00:00Z","first_posted":"2025-10-23","last_posted":"2025-10-23","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"339113","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"9396c5c28d4148aeb9ce0cce0f8c5ef8","title":"6515--NX EQ Lifts: Patient Transfer: Floor Based: Bariatric","solicitation_number":"36C10G26Q0006","notice_type":"r","base_type":"r","posted":"2025-10-23","posted_at":"2025-10-23T20:09:53.159Z","due_at":"2025-11-04T23:00:00Z","due_date":"2025-11-04","cancelled":false,"archived":true,"archive_date":"2026-01-03","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9396c5c28d4148aeb9ce0cce0f8c5ef8/view","enriched":true,"history":[{"index":3,"title":"6515--NX EQ Lifts: Patient Transfer: Floor Based: Bariatric","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-23T20:09:53.159Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"9396c5c28d4148aeb9ce0cce0f8c5ef8","solicitation_number":"36C10G26Q0006"}]}],"latest_notice_id":"9396c5c28d4148aeb9ce0cce0f8c5ef8","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-10-23","posted_at":"2025-10-23T20:09:53.159Z","created_at":"2025-10-23T20:09:50.952Z","modified_at":"2026-01-04T04:55:44.244Z","response_deadline":{"raw":"2025-11-04T17:00:00-06:00","utc":"2025-11-04T23:00:00Z","date":"2025-11-04","time":"17:00:00","timezone":"America/Chicago","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9396c5c28d4148aeb9ce0cce0f8c5ef8/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--NX EQ Lifts: Patient Transfer: Floor Based: Bariatric","agency":{"office":{"code":"36C10G","name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"organization_id":"100167093","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-01-03","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--NX EQ Lifts: Patient Transfer: Floor Based: Bariatric","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-10-23T20:09:53.159Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"9396c5c28d4148aeb9ce0cce0f8c5ef8","solicitation_number":"36C10G26Q0006"}],"contacts":[{"name":"Courtney Chattman","role":"primary","email":"Courtney.Chattman@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"9396c5c28d4148aeb9ce0cce0f8c5ef8","lineage_id":"9396c5c28d4148aeb9ce0cce0f8c5ef8","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-25T02:06:43.464923597Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T17:48:36.003679Z","row_sha256":"bb63c9ff676ce8dcfc1c66d51e14f662d2e0261a266fb5cdc3132420e9f8d7f1","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-25T02:06:43.464923597Z","first_seen_at":"2026-09-16T17:48:36.003679Z"},"description":{"html":"DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the NX EQ Lifts: Patient Transfer: Floor Based: Bariatric product line as a candidate for an Enterprise-wide (otherwise referred to as  national ) single Requirements contract award.\n  \nThe Department of Veterans Affairs  (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice to determine the availability and technical capabilities of qualified sources.\n \nThe SAC in conjunction with VHA is seeking a qualified source to provide EZ Way brand name or equal Lifts: Patient Transfer: Floor Based: Bariatric product on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders in accordance with FAR 16.503, to a supplier of this equipment. Vendors will be required to deliver Lifts: Patient Transfer: Floor Based: Bariatric to VA medical centers and facilities throughout the United States and its territories.\n \nThe anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees. The FAR Provision found at 52.204-7 requires that  All interested Offerors must be registered in SAM prior to submitting an offer or proposal.  You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nLifts: Patient Transfer: Floor Based: Bariatric are designed for hoisting and transferring a patient safely and with minimal physical effort up to 1000 lbs. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hook to accommodate clip-based slings, and the, lifting mechanisms; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms.  Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop.\n\nThe following Contract Line Items are being considered:\n\nContract Line Item#\nBrand\nPart Number\nDescription\nBase Period\nOption Period I\nOption Period II\nOption Period III\nOption Period IV \n0001\nEZ Way\nL1000PN-02\n1,000 lb. Smart Lift without scale with 2-inch casters (Upgrade)\n3\n3\n3\n3\n3\n0002\nEZ Way\nL1000PN-03\n1,000 lb. Smart Lift without scale with 3-inch casters (Standard)\n3\n3\n3\n3\n3\n0003\nEZ Way\nL1000PS-02\nÂ 1,000 lb. Smart Lift with scale with 2-inch casters (Upgrade)\n13\n13\n13\n13\n13\n0004\nEZ Way\nL1000PS-03\n1,000 lb. Smart Lift with scale with 3 inch casters (Standard\n24\n24\n24\n24\n24\n0005\nEZ Way\n500406\nDeluxe Sling Wipeable XXXXL\n13\n13\n13\n13\n13\n0006\nEZ Way\n500405\nDeluxe Sling Wipeable XXXL\n13\n13\n13\n13\n13\n0007\nEZ Way\n500412\nDeluxe Sling Wipeable XXXL with Head Support\n13\n13\n13\n13\n13\n0008\nEZ Way\n500274\nDeluxe Sling Mesh XXXL with Head Support\n13\n13\n13\n13\n13\n0009\nEZ Way\n500142\nDeluxe Sling XXXL\n13\n13\n13\n13\n13\n0010\nEZ Way\n500629\nDeluxe Sling Antimicrobial XXXL\n13\n13\n13\n13\n13\n0011\nEZ Way\n500630\nDeluxe Sling Antimicrobial XXXXL\n13\n13\n13\n13\n13\n0012\nEZ Way\n500636\nDeluxe Sling Antimicrobial XXXL with Head Support\n13\n13\n13\n13\n13\n0013\nEZ Way\n500914\nDeluxe Sling XXXXL\n13\n13\n13\n13\n13\n0014\nEZ Way\n50325\nDeluxe Sling XXXL with Head Support\n13\n13\n13\n13\n13\n0015\nEZ Way\n50701\nAccessory Bag - Bariatric\n13\n13\n13\n13\n13\n0016\nEZ Way\n500232\nMulti-Purpose Sling XXXL\n13\n13\n13\n13\n13\n0017\nEZ Way\n500418\nMulti-Purpose Sling Wipeable XXXL\n13\n13\n13\n13\n13\n0018\nEZ Way\n500446\nLimb Lifting & Turning Strap Kit Wipeable XL (includes 2 Wipeable Straps with 2 Carabiners)\n13\n13\n13\n13\n13\n0019\nEZ Way\n500463\nWalking Harness XXL\n13\n13\n13\n13\n13\n0020\nEZ Way\n500384\nGait Training Sling XXL\n13\n13\n13\n13\n13\n0021\nEZ Way\n500944\nBi-Directional Turning Sling (Twin Turner) Bariatric\n13\n13\n13\n13\n13\n0022\nEZ Way\n500193\nHip Sling XXXL\n13\n13\n13\n13\n13\n0023\nEZ Way\n500325\nRepositioning & Turning Sheet Black Spacer for Low Air Loss Beds & Skin Integrity 42\"W x 75\"L\n13\n13\n13\n13\n13\n\nThe VA is seeking vendors who can provide EZ Way Lifts: Patient Transfer: Floor Based: Bariatric or equal as listed above which meet all the following salient characteristics (SC):\n \nCLINs 0001-0004 apply to SCs 1-12. CLINs 0005-0023 apply to the SC 13. \n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nLift must be able to roll within a room while simultaneously suspending the patient. Must be able to take a patient to a toilet in an adjoining room.\nLiterature Review\nSC 2\nLifting range that allows floor rescue and ambulation of patients, with Spreader bar that can reach 26.5 inches from the floor or lower and reach at least 65.5 inches or higher.\nLiterature Review\nSC3\nLeg clearance of 4.5 inches from the floor or lower.\nLiterature Review\nSC 4\nLift options must be available with or without scale.\nLiterature Review\nSC 5\nLift weight capacity that accommodates patients weighing up to 1000lbs.\nLiterature Review\nSC 6\nLifting must be motorized using battery power.\nLiterature Review\nSC 7\nVendors shall provide verification that Lifts and Slings are compliant with ISO 10535.\nLiterature Review\nSC 8\nLift must provide emergency stop and manual emergency lowering.\nLiterature Review\nSC 9\nEmergency stop must not allow descent of a load unless emergency lowering controls are activated.\nLiterature Review\nSC 10\nLift must demonstrate Max exterior width with legs closed 34.5 inches.\nLiterature Review\nSC 11\nLift must be allowed to be used with ambulation slings.\nLiterature Review\nSC 12\nLift must be allowed to be used with repositioning slings.\nLiterature Review\nSC 13\nSlings are available in sizes accommodating patients who weigh up to 1000 pounds.\nLiterature Review\n\n3.0 SUB-FACTORS\n\nSafety\nAll features and functions of the offered device will be evaluated for the ability to safely lift, evacuate, and transfer patients. Areas include but are not limited to the following: \n\nSafety and transferring patients\nEase of lift base widening/narrowing at maximum capacity (such as stated force to use a lever at maximum capacity, or electrical widening/narrowing at maximum capacity)\nEmergency lowering without tools\nScale display location at or near caregiver eye level, preventing having to reach over, above, or around a patient to read the measurement.\nAbility to be disinfected using hospital approved disinfectants/cleaners and directions\n\nDesign\nAll design features and functions of the offered device will be evaluated. Areas include but are not limited to the following: \n\nPatient weight capacity\nProvide disposable, wipeable, and washable slings or allow use of other manufacturers  slings\nAvailability of extra or optional features such as (sling styles, compatibility with other manufacturers  loop-based slings, sling sizes, spare battery and remote wall charger)\nLocation and ease of use of features \nExtra wheel height options\nLegs adjust to wider interior width to accommodate bariatric equipment\nNarrower total external width with legs closed \nLoop-based hanger bar convertible between 2-point and 4-point \nDisposable slings available\nWhether scale lowers max lifting height below requirements\nIs the scale internal or external\nScale option with capacity equal to the lift\n\nPerformance\nDevice will be evaluated for its ability to perform its intended function. Areas include but are not limited to:\n\nLifting/Weight capacity of device\nPortability and Maneuverability of device\nEase of lift base widening/narrowing   \nEase of transferring patients\nLongevity of battery\nHigher battery capacity and/or number of lifts at maximum weight on a fully charged battery\n\nQuality/Construction\nAll aspects of the construction and quality of material of the device will be evaluated including but not limited to:\n\nRequired frequency of maintenance and replacement of parts\nService/Support Options\nTraining Options\nLife Span/warranty\nBuy American Act/Trade Agreement Act Compliant (TBD)\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\n \nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nIf applicable, vendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nSAM Unique Entity Identifier (UEI) / CAGE Code\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf the distributor, provide manufacturer s full name, business size and address.\n \nCountry of Origin designation for all products.\n\n Ability to provide uninterrupted supply of products on a national scale.\n\n Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n \n Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\n Authorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","text":"DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the NX EQ Lifts: Patient Transfer: Floor Based: Bariatric product line as a candidate for an Enterprise-wide (otherwise referred to as national ) single Requirements contract award.\n\nThe Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice to determine the availability and technical capabilities of qualified sources.\n\nThe SAC in conjunction with VHA is seeking a qualified source to provide EZ Way brand name or equal Lifts: Patient Transfer: Floor Based: Bariatric product on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders in accordance with FAR 16.503, to a supplier of this equipment. Vendors will be required to deliver Lifts: Patient Transfer: Floor Based: Bariatric to VA medical centers and facilities throughout the United States and its territories.\n\nThe anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees. The FAR Provision found at 52.204-7 requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nLifts: Patient Transfer: Floor Based: Bariatric are designed for hoisting and transferring a patient safely and with minimal physical effort up to 1000 lbs. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hook to accommodate clip-based slings, and the, lifting mechanisms; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms. Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop.\n\nThe following Contract Line Items are being considered:\n\nContract Line Item#\nBrand\nPart Number\nDescription\nBase Period\nOption Period I\nOption Period II\nOption Period III\nOption Period IV\n0001\nEZ Way\nL1000PN-02\n1,000 lb. Smart Lift without scale with 2-inch casters (Upgrade)\n3\n3\n3\n3\n3\n0002\nEZ Way\nL1000PN-03\n1,000 lb. Smart Lift without scale with 3-inch casters (Standard)\n3\n3\n3\n3\n3\n0003\nEZ Way\nL1000PS-02\nÂ 1,000 lb. Smart Lift with scale with 2-inch casters (Upgrade)\n13\n13\n13\n13\n13\n0004\nEZ Way\nL1000PS-03\n1,000 lb. Smart Lift with scale with 3 inch casters (Standard\n24\n24\n24\n24\n24\n0005\nEZ Way\n500406\nDeluxe Sling Wipeable XXXXL\n13\n13\n13\n13\n13\n0006\nEZ Way\n500405\nDeluxe Sling Wipeable XXXL\n13\n13\n13\n13\n13\n0007\nEZ Way\n500412\nDeluxe Sling Wipeable XXXL with Head Support\n13\n13\n13\n13\n13\n0008\nEZ Way\n500274\nDeluxe Sling Mesh XXXL with Head Support\n13\n13\n13\n13\n13\n0009\nEZ Way\n500142\nDeluxe Sling XXXL\n13\n13\n13\n13\n13\n0010\nEZ Way\n500629\nDeluxe Sling Antimicrobial XXXL\n13\n13\n13\n13\n13\n0011\nEZ Way\n500630\nDeluxe Sling Antimicrobial XXXXL\n13\n13\n13\n13\n13\n0012\nEZ Way\n500636\nDeluxe Sling Antimicrobial XXXL with Head Support\n13\n13\n13\n13\n13\n0013\nEZ Way\n500914\nDeluxe Sling XXXXL\n13\n13\n13\n13\n13\n0014\nEZ Way\n50325\nDeluxe Sling XXXL with Head Support\n13\n13\n13\n13\n13\n0015\nEZ Way\n50701\nAccessory Bag - Bariatric\n13\n13\n13\n13\n13\n0016\nEZ Way\n500232\nMulti-Purpose Sling XXXL\n13\n13\n13\n13\n13\n0017\nEZ Way\n500418\nMulti-Purpose Sling Wipeable XXXL\n13\n13\n13\n13\n13\n0018\nEZ Way\n500446\nLimb Lifting & Turning Strap Kit Wipeable XL (includes 2 Wipeable Straps with 2 Carabiners)\n13\n13\n13\n13\n13\n0019\nEZ Way\n500463\nWalking Harness XXL\n13\n13\n13\n13\n13\n0020\nEZ Way\n500384\nGait Training Sling XXL\n13\n13\n13\n13\n13\n0021\nEZ Way\n500944\nBi-Directional Turning Sling (Twin Turner) Bariatric\n13\n13\n13\n13\n13\n0022\nEZ Way\n500193\nHip Sling XXXL\n13\n13\n13\n13\n13\n0023\nEZ Way\n500325\nRepositioning & Turning Sheet Black Spacer for Low Air Loss Beds & Skin Integrity 42\"W x 75\"L\n13\n13\n13\n13\n13\n\nThe VA is seeking vendors who can provide EZ Way Lifts: Patient Transfer: Floor Based: Bariatric or equal as listed above which meet all the following salient characteristics (SC):\n\nCLINs 0001-0004 apply to SCs 1-12. CLINs 0005-0023 apply to the SC 13.\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nLift must be able to roll within a room while simultaneously suspending the patient. Must be able to take a patient to a toilet in an adjoining room.\nLiterature Review\nSC 2\nLifting range that allows floor rescue and ambulation of patients, with Spreader bar that can reach 26.5 inches from the floor or lower and reach at least 65.5 inches or higher.\nLiterature Review\nSC3\nLeg clearance of 4.5 inches from the floor or lower.\nLiterature Review\nSC 4\nLift options must be available with or without scale.\nLiterature Review\nSC 5\nLift weight capacity that accommodates patients weighing up to 1000lbs.\nLiterature Review\nSC 6\nLifting must be motorized using battery power.\nLiterature Review\nSC 7\nVendors shall provide verification that Lifts and Slings are compliant with ISO 10535.\nLiterature Review\nSC 8\nLift must provide emergency stop and manual emergency lowering.\nLiterature Review\nSC 9\nEmergency stop must not allow descent of a load unless emergency lowering controls are activated.\nLiterature Review\nSC 10\nLift must demonstrate Max exterior width with legs closed 34.5 inches.\nLiterature Review\nSC 11\nLift must be allowed to be used with ambulation slings.\nLiterature Review\nSC 12\nLift must be allowed to be used with repositioning slings.\nLiterature Review\nSC 13\nSlings are available in sizes accommodating patients who weigh up to 1000 pounds.\nLiterature Review\n\n3.0 SUB-FACTORS\n\nSafety\nAll features and functions of the offered device will be evaluated for the ability to safely lift, evacuate, and transfer patients. Areas include but are not limited to the following:\n\nSafety and transferring patients\nEase of lift base widening/narrowing at maximum capacity (such as stated force to use a lever at maximum capacity, or electrical widening/narrowing at maximum capacity)\nEmergency lowering without tools\nScale display location at or near caregiver eye level, preventing having to reach over, above, or around a patient to read the measurement.\nAbility to be disinfected using hospital approved disinfectants/cleaners and directions\n\nDesign\nAll design features and functions of the offered device will be evaluated. Areas include but are not limited to the following:\n\nPatient weight capacity\nProvide disposable, wipeable, and washable slings or allow use of other manufacturers slings\nAvailability of extra or optional features such as (sling styles, compatibility with other manufacturers loop-based slings, sling sizes, spare battery and remote wall charger)\nLocation and ease of use of features\nExtra wheel height options\nLegs adjust to wider interior width to accommodate bariatric equipment\nNarrower total external width with legs closed\nLoop-based hanger bar convertible between 2-point and 4-point\nDisposable slings available\nWhether scale lowers max lifting height below requirements\nIs the scale internal or external\nScale option with capacity equal to the lift\n\nPerformance\nDevice will be evaluated for its ability to perform its intended function. Areas include but are not limited to:\n\nLifting/Weight capacity of device\nPortability and Maneuverability of device\nEase of lift base widening/narrowing\nEase of transferring patients\nLongevity of battery\nHigher battery capacity and/or number of lifts at maximum weight on a fully charged battery\n\nQuality/Construction\nAll aspects of the construction and quality of material of the device will be evaluated including but not limited to:\n\nRequired frequency of maintenance and replacement of parts\nService/Support Options\nTraining Options\nLife Span/warranty\nBuy American Act/Trade Agreement Act Compliant (TBD)\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\n\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nIf applicable, vendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nSAM Unique Entity Identifier (UEI) / CAGE Code\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf the distributor, provide manufacturer s full name, business size and address.\n\nCountry of Origin designation for all products.\n\nAbility to provide uninterrupted supply of products on a national scale.\n\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10G26Q0006","place_of_performance":{"street":"Enterprise-wide","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6515"}],"due_at":"2025-11-04T23:00:00Z","due_date":"2025-11-04","closes_at":"2025-11-04T23:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-10-25T02:50:49.747137Z","principal_notice_id":"9396c5c28d4148aeb9ce0cce0f8c5ef8","description":{"text":"DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the NX EQ Lifts: Patient Transfer: Floor Based: Bariatric product line as a candidate for an Enterprise-wide (otherwise referred to as national ) single Requirements contract award.\n\nThe Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice to determine the availability and technical capabilities of qualified sources.\n\nThe SAC in conjunction with VHA is seeking a qualified source to provide EZ Way brand name or equal Lifts: Patient Transfer: Floor Based: Bariatric product on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders in accordance with FAR 16.503, to a supplier of this equipment. Vendors will be required to deliver Lifts: Patient Transfer: Floor Based: Bariatric to VA medical centers and facilities throughout the United States and its territories.\n\nThe anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees. The FAR Provision found at 52.204-7 requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nLifts: Patient Transfer: Floor Based: Bariatric are designed for hoisting and transferring a patient safely and with minimal physical effort up to 1000 lbs. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hook to accommodate clip-based slings, and the, lifting mechanisms; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms. Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop.\n\nThe following Contract Line Items are being considered:\n\nContract Line Item#\nBrand\nPart Number\nDescription\nBase Period\nOption Period I\nOption Period II\nOption Period III\nOption Period IV\n0001\nEZ Way\nL1000PN-02\n1,000 lb. Smart Lift without scale with 2-inch casters (Upgrade)\n3\n3\n3\n3\n3\n0002\nEZ Way\nL1000PN-03\n1,000 lb. Smart Lift without scale with 3-inch casters (Standard)\n3\n3\n3\n3\n3\n0003\nEZ Way\nL1000PS-02\nÂ 1,000 lb. Smart Lift with scale with 2-inch casters (Upgrade)\n13\n13\n13\n13\n13\n0004\nEZ Way\nL1000PS-03\n1,000 lb. Smart Lift with scale with 3 inch casters (Standard\n24\n24\n24\n24\n24\n0005\nEZ Way\n500406\nDeluxe Sling Wipeable XXXXL\n13\n13\n13\n13\n13\n0006\nEZ Way\n500405\nDeluxe Sling Wipeable XXXL\n13\n13\n13\n13\n13\n0007\nEZ Way\n500412\nDeluxe Sling Wipeable XXXL with Head Support\n13\n13\n13\n13\n13\n0008\nEZ Way\n500274\nDeluxe Sling Mesh XXXL with Head Support\n13\n13\n13\n13\n13\n0009\nEZ Way\n500142\nDeluxe Sling XXXL\n13\n13\n13\n13\n13\n0010\nEZ Way\n500629\nDeluxe Sling Antimicrobial XXXL\n13\n13\n13\n13\n13\n0011\nEZ Way\n500630\nDeluxe Sling Antimicrobial XXXXL\n13\n13\n13\n13\n13\n0012\nEZ Way\n500636\nDeluxe Sling Antimicrobial XXXL with Head Support\n13\n13\n13\n13\n13\n0013\nEZ Way\n500914\nDeluxe Sling XXXXL\n13\n13\n13\n13\n13\n0014\nEZ Way\n50325\nDeluxe Sling XXXL with Head Support\n13\n13\n13\n13\n13\n0015\nEZ Way\n50701\nAccessory Bag - Bariatric\n13\n13\n13\n13\n13\n0016\nEZ Way\n500232\nMulti-Purpose Sling XXXL\n13\n13\n13\n13\n13\n0017\nEZ Way\n500418\nMulti-Purpose Sling Wipeable XXXL\n13\n13\n13\n13\n13\n0018\nEZ Way\n500446\nLimb Lifting & Turning Strap Kit Wipeable XL (includes 2 Wipeable Straps with 2 Carabiners)\n13\n13\n13\n13\n13\n0019\nEZ Way\n500463\nWalking Harness XXL\n13\n13\n13\n13\n13\n0020\nEZ Way\n500384\nGait Training Sling XXL\n13\n13\n13\n13\n13\n0021\nEZ Way\n500944\nBi-Directional Turning Sling (Twin Turner) Bariatric\n13\n13\n13\n13\n13\n0022\nEZ Way\n500193\nHip Sling XXXL\n13\n13\n13\n13\n13\n0023\nEZ Way\n500325\nRepositioning & Turning Sheet Black Spacer for Low Air Loss Beds & Skin Integrity 42\"W x 75\"L\n13\n13\n13\n13\n13\n\nThe VA is seeking vendors who can provide EZ Way Lifts: Patient Transfer: Floor Based: Bariatric or equal as listed above which meet all the following salient characteristics (SC):\n\nCLINs 0001-0004 apply to SCs 1-12. CLINs 0005-0023 apply to the SC 13.\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nLift must be able to roll within a room while simultaneously suspending the patient. Must be able to take a patient to a toilet in an adjoining room.\nLiterature Review\nSC 2\nLifting range that allows floor rescue and ambulation of patients, with Spreader bar that can reach 26.5 inches from the floor or lower and reach at least 65.5 inches or higher.\nLiterature Review\nSC3\nLeg clearance of 4.5 inches from the floor or lower.\nLiterature Review\nSC 4\nLift options must be available with or without scale.\nLiterature Review\nSC 5\nLift weight capacity that accommodates patients weighing up to 1000lbs.\nLiterature Review\nSC 6\nLifting must be motorized using battery power.\nLiterature Review\nSC 7\nVendors shall provide verification that Lifts and Slings are compliant with ISO 10535.\nLiterature Review\nSC 8\nLift must provide emergency stop and manual emergency lowering.\nLiterature Review\nSC 9\nEmergency stop must not allow descent of a load unless emergency lowering controls are activated.\nLiterature Review\nSC 10\nLift must demonstrate Max exterior width with legs closed 34.5 inches.\nLiterature Review\nSC 11\nLift must be allowed to be used with ambulation slings.\nLiterature Review\nSC 12\nLift must be allowed to be used with repositioning slings.\nLiterature Review\nSC 13\nSlings are available in sizes accommodating patients who weigh up to 1000 pounds.\nLiterature Review\n\n3.0 SUB-FACTORS\n\nSafety\nAll features and functions of the offered device will be evaluated for the ability to safely lift, evacuate, and transfer patients. Areas include but are not limited to the following:\n\nSafety and transferring patients\nEase of lift base widening/narrowing at maximum capacity (such as stated force to use a lever at maximum capacity, or electrical widening/narrowing at maximum capacity)\nEmergency lowering without tools\nScale display location at or near caregiver eye level, preventing having to reach over, above, or around a patient to read the measurement.\nAbility to be disinfected using hospital approved disinfectants/cleaners and directions\n\nDesign\nAll design features and functions of the offered device will be evaluated. Areas include but are not limited to the following:\n\nPatient weight capacity\nProvide disposable, wipeable, and washable slings or allow use of other manufacturers slings\nAvailability of extra or optional features such as (sling styles, compatibility with other manufacturers loop-based slings, sling sizes, spare battery and remote wall charger)\nLocation and ease of use of features\nExtra wheel height options\nLegs adjust to wider interior width to accommodate bariatric equipment\nNarrower total external width with legs closed\nLoop-based hanger bar convertible between 2-point and 4-point\nDisposable slings available\nWhether scale lowers max lifting height below requirements\nIs the scale internal or external\nScale option with capacity equal to the lift\n\nPerformance\nDevice will be evaluated for its ability to perform its intended function. Areas include but are not limited to:\n\nLifting/Weight capacity of device\nPortability and Maneuverability of device\nEase of lift base widening/narrowing\nEase of transferring patients\nLongevity of battery\nHigher battery capacity and/or number of lifts at maximum weight on a fully charged battery\n\nQuality/Construction\nAll aspects of the construction and quality of material of the device will be evaluated including but not limited to:\n\nRequired frequency of maintenance and replacement of parts\nService/Support Options\nTraining Options\nLife Span/warranty\nBuy American Act/Trade Agreement Act Compliant (TBD)\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\n\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nIf applicable, vendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nSAM Unique Entity Identifier (UEI) / CAGE Code\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf the distributor, provide manufacturer s full name, business size and address.\n\nCountry of Origin designation for all products.\n\nAbility to provide uninterrupted supply of products on a national scale.\n\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAuthorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","html":"DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the NX EQ Lifts: Patient Transfer: Floor Based: Bariatric product line as a candidate for an Enterprise-wide (otherwise referred to as  national ) single Requirements contract award.\n  \nThe Department of Veterans Affairs  (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice to determine the availability and technical capabilities of qualified sources.\n \nThe SAC in conjunction with VHA is seeking a qualified source to provide EZ Way brand name or equal Lifts: Patient Transfer: Floor Based: Bariatric product on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders in accordance with FAR 16.503, to a supplier of this equipment. Vendors will be required to deliver Lifts: Patient Transfer: Floor Based: Bariatric to VA medical centers and facilities throughout the United States and its territories.\n \nThe anticipated period of performance is for one (1) 12-month base period with four (4) 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\n\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees. The FAR Provision found at 52.204-7 requires that  All interested Offerors must be registered in SAM prior to submitting an offer or proposal.  You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n\n2.0 SCOPE\n\nLifts: Patient Transfer: Floor Based: Bariatric are designed for hoisting and transferring a patient safely and with minimal physical effort up to 1000 lbs. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hook to accommodate clip-based slings, and the, lifting mechanisms; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms.  Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop.\n\nThe following Contract Line Items are being considered:\n\nContract Line Item#\nBrand\nPart Number\nDescription\nBase Period\nOption Period I\nOption Period II\nOption Period III\nOption Period IV \n0001\nEZ Way\nL1000PN-02\n1,000 lb. Smart Lift without scale with 2-inch casters (Upgrade)\n3\n3\n3\n3\n3\n0002\nEZ Way\nL1000PN-03\n1,000 lb. Smart Lift without scale with 3-inch casters (Standard)\n3\n3\n3\n3\n3\n0003\nEZ Way\nL1000PS-02\nÂ 1,000 lb. Smart Lift with scale with 2-inch casters (Upgrade)\n13\n13\n13\n13\n13\n0004\nEZ Way\nL1000PS-03\n1,000 lb. Smart Lift with scale with 3 inch casters (Standard\n24\n24\n24\n24\n24\n0005\nEZ Way\n500406\nDeluxe Sling Wipeable XXXXL\n13\n13\n13\n13\n13\n0006\nEZ Way\n500405\nDeluxe Sling Wipeable XXXL\n13\n13\n13\n13\n13\n0007\nEZ Way\n500412\nDeluxe Sling Wipeable XXXL with Head Support\n13\n13\n13\n13\n13\n0008\nEZ Way\n500274\nDeluxe Sling Mesh XXXL with Head Support\n13\n13\n13\n13\n13\n0009\nEZ Way\n500142\nDeluxe Sling XXXL\n13\n13\n13\n13\n13\n0010\nEZ Way\n500629\nDeluxe Sling Antimicrobial XXXL\n13\n13\n13\n13\n13\n0011\nEZ Way\n500630\nDeluxe Sling Antimicrobial XXXXL\n13\n13\n13\n13\n13\n0012\nEZ Way\n500636\nDeluxe Sling Antimicrobial XXXL with Head Support\n13\n13\n13\n13\n13\n0013\nEZ Way\n500914\nDeluxe Sling XXXXL\n13\n13\n13\n13\n13\n0014\nEZ Way\n50325\nDeluxe Sling XXXL with Head Support\n13\n13\n13\n13\n13\n0015\nEZ Way\n50701\nAccessory Bag - Bariatric\n13\n13\n13\n13\n13\n0016\nEZ Way\n500232\nMulti-Purpose Sling XXXL\n13\n13\n13\n13\n13\n0017\nEZ Way\n500418\nMulti-Purpose Sling Wipeable XXXL\n13\n13\n13\n13\n13\n0018\nEZ Way\n500446\nLimb Lifting & Turning Strap Kit Wipeable XL (includes 2 Wipeable Straps with 2 Carabiners)\n13\n13\n13\n13\n13\n0019\nEZ Way\n500463\nWalking Harness XXL\n13\n13\n13\n13\n13\n0020\nEZ Way\n500384\nGait Training Sling XXL\n13\n13\n13\n13\n13\n0021\nEZ Way\n500944\nBi-Directional Turning Sling (Twin Turner) Bariatric\n13\n13\n13\n13\n13\n0022\nEZ Way\n500193\nHip Sling XXXL\n13\n13\n13\n13\n13\n0023\nEZ Way\n500325\nRepositioning & Turning Sheet Black Spacer for Low Air Loss Beds & Skin Integrity 42\"W x 75\"L\n13\n13\n13\n13\n13\n\nThe VA is seeking vendors who can provide EZ Way Lifts: Patient Transfer: Floor Based: Bariatric or equal as listed above which meet all the following salient characteristics (SC):\n \nCLINs 0001-0004 apply to SCs 1-12. CLINs 0005-0023 apply to the SC 13. \n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nLift must be able to roll within a room while simultaneously suspending the patient. Must be able to take a patient to a toilet in an adjoining room.\nLiterature Review\nSC 2\nLifting range that allows floor rescue and ambulation of patients, with Spreader bar that can reach 26.5 inches from the floor or lower and reach at least 65.5 inches or higher.\nLiterature Review\nSC3\nLeg clearance of 4.5 inches from the floor or lower.\nLiterature Review\nSC 4\nLift options must be available with or without scale.\nLiterature Review\nSC 5\nLift weight capacity that accommodates patients weighing up to 1000lbs.\nLiterature Review\nSC 6\nLifting must be motorized using battery power.\nLiterature Review\nSC 7\nVendors shall provide verification that Lifts and Slings are compliant with ISO 10535.\nLiterature Review\nSC 8\nLift must provide emergency stop and manual emergency lowering.\nLiterature Review\nSC 9\nEmergency stop must not allow descent of a load unless emergency lowering controls are activated.\nLiterature Review\nSC 10\nLift must demonstrate Max exterior width with legs closed 34.5 inches.\nLiterature Review\nSC 11\nLift must be allowed to be used with ambulation slings.\nLiterature Review\nSC 12\nLift must be allowed to be used with repositioning slings.\nLiterature Review\nSC 13\nSlings are available in sizes accommodating patients who weigh up to 1000 pounds.\nLiterature Review\n\n3.0 SUB-FACTORS\n\nSafety\nAll features and functions of the offered device will be evaluated for the ability to safely lift, evacuate, and transfer patients. Areas include but are not limited to the following: \n\nSafety and transferring patients\nEase of lift base widening/narrowing at maximum capacity (such as stated force to use a lever at maximum capacity, or electrical widening/narrowing at maximum capacity)\nEmergency lowering without tools\nScale display location at or near caregiver eye level, preventing having to reach over, above, or around a patient to read the measurement.\nAbility to be disinfected using hospital approved disinfectants/cleaners and directions\n\nDesign\nAll design features and functions of the offered device will be evaluated. Areas include but are not limited to the following: \n\nPatient weight capacity\nProvide disposable, wipeable, and washable slings or allow use of other manufacturers  slings\nAvailability of extra or optional features such as (sling styles, compatibility with other manufacturers  loop-based slings, sling sizes, spare battery and remote wall charger)\nLocation and ease of use of features \nExtra wheel height options\nLegs adjust to wider interior width to accommodate bariatric equipment\nNarrower total external width with legs closed \nLoop-based hanger bar convertible between 2-point and 4-point \nDisposable slings available\nWhether scale lowers max lifting height below requirements\nIs the scale internal or external\nScale option with capacity equal to the lift\n\nPerformance\nDevice will be evaluated for its ability to perform its intended function. Areas include but are not limited to:\n\nLifting/Weight capacity of device\nPortability and Maneuverability of device\nEase of lift base widening/narrowing   \nEase of transferring patients\nLongevity of battery\nHigher battery capacity and/or number of lifts at maximum weight on a fully charged battery\n\nQuality/Construction\nAll aspects of the construction and quality of material of the device will be evaluated including but not limited to:\n\nRequired frequency of maintenance and replacement of parts\nService/Support Options\nTraining Options\nLife Span/warranty\nBuy American Act/Trade Agreement Act Compliant (TBD)\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\n \nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer (OEM) and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\n\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nIf applicable, vendors are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\n\nSAM Unique Entity Identifier (UEI) / CAGE Code\n\nBusiness Size\n\nManufacturer or Distributor\n\nIf the distributor, provide manufacturer s full name, business size and address.\n \nCountry of Origin designation for all products.\n\n Ability to provide uninterrupted supply of products on a national scale.\n\n Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\n \n Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\n Authorized Distributor Letter Certified by OEM with a current date.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"contacts":[{"name":"Courtney Chattman","role":"primary","email":"Courtney.Chattman@va.gov","title":"Contract Specialist"}],"place_of_performance":{"street":"Enterprise-wide","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"345f2eb797d4444c9f2d311f7c99d90b","name":"36C10G26Q0006_1.docx","kind":"file","mime_type":".docx","size_bytes":41648,"posted_at":"2025-10-23T20:09:53.159Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/345f2eb797d4444c9f2d311f7c99d90b/download","mirrored":false}],"awards":[],"related":[{"key":"36C10G27R0002","latest_notice_id":"f16ea5b6f90d4b3e903edd9b27a5c3aa","title":"6515--Patient Lifts and Slings for In Home Use","solicitation_number":"36C10G27R0002","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":4,"due_at":"2026-12-15T17:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"339113","psc":"6515","set_aside":"SBP","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open":[{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"N0010426QEJ19","latest_notice_id":"43eefc1812e24932a06b9e18e8f7e03b","title":"66--REAGENT POWDER","solicitation_number":"N0010426QEJ19","notice_type":"o","first_type":"o","first_posted":"2026-10-29","last_posted":"2026-10-29","notices":1,"due_at":"2026-11-30T20:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"},{"key":"N0010427QBB84","latest_notice_id":"34e1ae5135d948f0a44a6b0599aacab1","title":"REMOVABLE CONE,SPEC","solicitation_number":"N0010427QBB84","notice_type":"o","first_type":"o","first_posted":"2026-10-30","last_posted":"2026-10-30","notices":1,"due_at":"2026-11-30T20:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-31T03:50:03.904859Z"}],"similar_open_total":20,"indexable":false}