# NX EQ Capsule Endoscopy (VA-26-00006488)

Canonical: https://sealedbidder.com/opportunities/36c10g25q0114

- Solicitation number: 36C10G25Q0114
- Notice type: Sources sought
- Status: Closed. Deadline was August 22, 2025 at 3:30 PM EDT
- Department: Department of Veterans Affairs
- Contracting office: Strategic Acquisition Center Fredericksburg (36C10G)
- NAICS: 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing
- Product or service code: 6515 Medical and Surgical Instruments, Equipment, and Supplies
- Small business size standard: 1,250 employees (13 CFR 121.201, NAICS 334510)
- Who can bid, by location: Anywhere in the US. Location does not limit who can bid: a product shipped to the buyer, research at the performer's facility, or work at the contractor's site. A state shown is the delivery point.
- First posted: August 7, 2025
- Last posted: August 7, 2025
- SAM.gov: https://sam.gov/workspace/contract/opp/277fafe8e4e140ba82318253addf89e3/view

## Reading this notice

- Kind of notice: Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it.
- Who may compete: SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334510 (electromedical and electrotherapeutic apparatus manufacturing), means no more than 1,250 employees, counted with affiliates.
- What comes next: No solicitation was published under this number after the sources sought of August 7, 2025. An agency sometimes issues the solicitation under a new number.

## Description

1. DESCRIPTION

The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Capsule Endoscopy System product line as a candidate for a VA-wide (otherwise referred to as  national ) single Requirements contract award.

The North American Industry Classification System (NAICS) code for Capsule Endoscopy System is 334510   Endoscopic equipment, electromedical (e.g., bronchoscopes, colonoscopes, cystoscopes), manufacturing: 6515   Medical and Surgical Instruments, Equipment, and Supplies.

2.     SCOPE

This requirement will be IAW FAR clause 6.303, Brand Name which requires the quoter indicate that the product being offered is a Capsule Endoscopy System from Medtronic.

Capsule Endoscopy systems are designed to examine various points along the intestinal tract using images captured with a tiny ingestible video camera. These systems typically consist of three components: a disposable ingestible camera pill/capsule that is swallowed by the patient and that transmits video images as it passes through the gastrointestinal tract, a recorder used by the patient (e.g., worn on a belt around the waist) that receives the signals transmitted by the camera, and a workstation appropriate for processing and displaying the images from the recorder. Ingestible camera endoscopic video systems are used to detect abnormalities (e.g., angioectasia, ulcers, tumors) especially in areas of the small intestine that are difficult or impossible to reach using endoscopes.

Contract Line Items
Manufacturer
Part Number
Description
0001
Medtronic
FGS-0504
USBC 2PK
0002
Medtronic
FGS-0688
PillCamÂ® GENIUS SB 1 PK US
0003
Medtronic
FGS-0802
SOFTWARE PillCamÂ® 9.7 US
0004
Medtronic
FGS-0806
Genius Sync Agent (GSA) OFFLINE PillCamÂ® US
0005
Medtronic
FGS-0808
BARCODE SCANNER
0006
Medtronic
FGS-0668
PillCamÂ® Patency Capsule 5-Pack
0007
Medtronic
FGS-0347
PillCamÂ® RECORDER DR3 X1
0008
Medtronic
FGS-0355
PillCamÂ® RECORDER CRADLE DR3X1
0009
Medtronic
FGS-0362
PillCamÂ® RECORD ACCESSORIESDR3
0010
Medtronic
FGS-0498
PillCamÂ® SB 3-EX CAPSULE 5-PACK
0011
Medtronic
FGS-0499
PillCamÂ® SB 3-EX CAPSULE 10-PK
0012
Medtronic
FGS-0590
PillCamÂ® SENSOR BELT MS SB
0013
Medtronic
FGS-0591
PillCamÂ® SENSOR ARRAY MS
0014
Medtronic
FGS-0453
PillCamÂ® SENSOR SLEEVES 10-PACK

The Department of Veterans Affairs (VA) is seeking vendors who can provide Medtronic Capsule Endoscopy System as listed below which meet all the following salient characteristics:

SC #
SALIENT CHARACTERISTICS
Applicable CLIN
METHOD OF EVALUATION
SC   Literature Map
SC 1
Allow for direct visualization of small bowel via the paired recorder
0010, 0011
Literature Review
Medtronic
Page #39, 57
SC 2
Adaptive frame technology allows the capsule to capture images faster if the capsule is moving faster and slower if the capsule is moving slower and produces quality images
0002, 0010, 0011
Literature Review
Medtronic
Page #40
SC 3
Software for enhanced reading capabilities and reduced reading time
0003
Literature Review
Medtronic
Page #67
SC4
Optimized optics that deliver clear images and provide greater diagnostic ability
0002, 0010, 0011
Literature Review
Medtronic
Page #67 - 70
SC 5
Recorder which actively communicates with the capsule and indicates when paired with capsule
0002
Literature Review
Medtronic
Page #9
SC 6
Pillcam does not need to be retrieved to read data.
0002, 0010, 0011
Literature Review
Medtronic
Page #14, 40
SC 7
System must have FDA 510 K Approval
All
Literature Review
Medtronic
Page #56 - 66
SC 8
The Recorder system must have the ability to take video and still images.
0010, 0011
Literature Review
Medtronic
Page #57
SC 9
Patency capsule that can be used to verify an unobstructed small bowel prior to capsule endoscopy procedure
0002, 0010, 0011
Literature Review
Medtronic
Page #41
SC 10
Capable of remote ingestion
0002, 0010, 0011
Literature Review
Medtronic
Page #40
SC 11
System does not require capital equipment
0002
Literature Review
Medtronic
Page #40

CLINs
MANUFACTURERS
PART NUMBERS
DESCRIPTION
BASE YEAR
OPTION   YEAR ONE
OPTION   YEAR TWO
OPTION   YEAR THREE
OPTION   YEAR FOUR
0001
Â 
Â 
Â 
39
34
34
34
34
0002
Â 
Â 
Â 
39
34
34
34
34
0003
Â 
Â 
Â 
39
34
34
34
34
0004
Â 
Â 
Â 
39
34
34
34
34
0005
Â 
Â 
Â 
39
34
34
34
34
0006
Â 
Â 
Â 
39
34
34
34
34
0007
Â 
Â 
Â 
39
34
34
34
34
0008
Â 
Â 
Â 
39
34
34
34
34
0009
Â 
Â 
Â 
39
34
34
34
34
0010
Â 
Â 
Â 
39
34
34
34
34
0011
Â 
Â 
Â 
39
34
34
34
34
0012
Â 
Â 
Â 
39
34
34
34
34
0013
Â 
Â 
Â 
39
34
34
34
34
0014
Â 
Â 
Â 
39
34
34
34
34

Responses to this Sources Sought Notice shall include the following:Â Â 
Â Â Â Â Â Â Â Â Â 
1)Â Â Â  Full name and address of company
2)Â Â Â  DUNS number/ CAGE Code/ SAM UIE
3)Â Â Â  Business Size
4)Â Â Â  Manufacturer or Distributor
a.Â Â Â  If distributor provide full name, business size and address of manufacturer.
5)Â Â Â  Country of Origin designation for all products.
6)Â Â Â  Ability to provide uninterrupted supply of products on a national scale.
7)Â Â Â  Technical Literature that clearly shows product(s) meet the identified salient characteristics (if submitting an  or-equal  item).
8)Â Â Â  Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
9)Â Â Â  All small business, VOSB, SDVOSB distributors shall provide a valid letter of authorization from the manufacturer of the product/brand that you intend to offer. The letter shall be printed on the manufacturers letter head and be no older than 6 months old. The letter shall also clearly state how long your agreement is place with the manufacturer, e.g., 6 month, 4 years, expires 4 years from XXX, end of 2025, etc. The letter shall also be signed by a legally, authorized representative of the manufacturer.
Authorized Distributor Letter Certified by OEM with a current date.

## Attachments

- [va.gov](https://www.va.gov/opal/sac/index.asp) (link)

## Open now in the same industry

11 open in NAICS 334510.

- NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq (75N98027Q00094), due November 27, 2026 at 11:00 AM EST. https://sealedbidder.com/opportunities/75n98027q00094
- NX EQ Ultrasonic Aspirator System: Tissue Ablation (VA-27-00010132) (36C10X27R0005), due December 1, 2026 at 10:00 AM EST. https://sealedbidder.com/opportunities/36c10x27r0005
- Copy of NX EQ Thulium Fiber Laser (VA-27-00003102) (36C10X27Q0033), due December 10, 2026 at 11:59 PM EST. https://sealedbidder.com/opportunities/36c10x27q0033

## Publications

- August 7, 2025: Sources sought, due August 22, 2025 at 3:30 PM EDT. Notice 277fafe8e4e140ba82318253addf89e3. https://sam.gov/workspace/contract/opp/277fafe8e4e140ba82318253addf89e3/view

## Points of contact

- Hosea Berkley, Contracting Specialist, hosea.berkley@va.gov, 202-276-2992

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://sealedbidder.com/opportunities/36c10g25q0114.