{"canonical":"https://sealedbidder.com/opportunities/36c10g25q0084","key":"36C10G25Q0084","url":"https://sealedbidder.com/opportunities/36c10g25q0084","title":"6515--NX EQ Lifts: Patient Transfer: Floor: Loop Based","solicitation_number":"36C10G25Q0084","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-06-10T20:30:00Z","first_posted":"2025-05-28","last_posted":"2025-05-28","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"339113","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"2c0067f7c38d411bab9b084549ccc249","title":"6515--NX EQ Lifts: Patient Transfer: Floor: Loop Based","solicitation_number":"36C10G25Q0084","notice_type":"r","base_type":"r","posted":"2025-05-28","posted_at":"2025-05-28T20:10:14.747Z","due_at":"2025-06-10T20:30:00Z","due_date":"2025-06-10","cancelled":false,"archived":true,"archive_date":"2025-09-17","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2c0067f7c38d411bab9b084549ccc249/view","enriched":true,"history":[{"index":3,"title":"6515--NX EQ Lifts: Patient Transfer: Floor: Loop Based","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-28T20:10:14.747Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2c0067f7c38d411bab9b084549ccc249","solicitation_number":"36C10G25Q0084"}]}],"latest_notice_id":"2c0067f7c38d411bab9b084549ccc249","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-05-28","posted_at":"2025-05-28T20:10:14.747Z","created_at":"2025-05-28T20:10:12.560Z","modified_at":"2025-09-18T03:55:51.428Z","response_deadline":{"raw":"2025-06-10T16:30:00-04:00","utc":"2025-06-10T20:30:00Z","date":"2025-06-10","time":"16:30:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2c0067f7c38d411bab9b084549ccc249/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"6515--NX EQ Lifts: Patient Transfer: Floor: Loop Based","agency":{"office":{"code":"36C10G","name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"organization_id":"100167093","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-09-17","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--NX EQ Lifts: Patient Transfer: Floor: Loop Based","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-05-28T20:10:14.747Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2c0067f7c38d411bab9b084549ccc249","solicitation_number":"36C10G25Q0084"}],"contacts":[{"name":"Jalima J. Jones","role":"primary","email":"Jalima.Jones@va.gov","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"2c0067f7c38d411bab9b084549ccc249","lineage_id":"2c0067f7c38d411bab9b084549ccc249","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-13T12:11:18.097728352Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"e6bdda64579187d3671647a680fdd68c9e9082c47425d977f7964e2d1f4601d9","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-13T12:11:18.097728352Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"DESCRIPTION\n\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Lifts: Patient Transfer: Floor: Loop Based product line as a candidate for a VA-wide (otherwise referred to as  national ) single Requirements contract award.  \nThe Department of Veterans Affairs  (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. \nThe SAC in conjunction with VHA is seeking a qualified source to provide EZ WayÂ® brand name or equal the Lifts: Patient Transfer: Floor: Loop Based on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Lifts: Patient Transfer: Floor: Loop Based to VA medical centers and facilities throughout the United States and its territories. \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113- Surgical Appliance and Supplies Manufacturing, Product Service Code: 6515   Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that  All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation.  You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.\nSubmissions for this  source sought  shall be submitted by email no later than June 5th, 2025, at 4:30pm EST to all the following:\nJalima.Jones@va.gov\nSara.Vickroy@va.gov\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\n\nLifts: Patient: Transfer: Floor: Loop Based are designed for hoisting and transferring a patient safely and with minimal physical effort. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hooks to accommodate loop-based slings, and the lifting mechanism; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms.  Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop. \nThe following Contract Line-Items Number (CLIN) are being considered:\nCLIN\n\nManufacturer\nPart Number\nDescription\n0001\nEZ Way\nL500PN-03\nLoop-based full-body patient lift with loop-based hanger bar, 500-pound capacity minimum.\n0002\nEZ Way\nL500PS-03\nOption for a Scale with the ability to lift with capacity equal to lift capacity.\n0003\nEZ Way\nLLB500PN\nLow base lift with option to fit under stretcher with 2.5-inch clearance.\n0004\nEZ Way\n11871\nBattery Replacement\n0005\nEZ Way\n11860\nWall Mount Battery Charger\n0006\nEZ Way\nCaster Option\nOptional Caster Sizes (Lift is available in optional 2\", 4\" or 5\" caster)\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide EZ WayÂ® brand name or equal Lifts: Patient Transfer: Floor: Loop Based as listed above or equal commodities which meet all the following salient characteristics (SCs):\nApply to the following SC s to CLINs 0001   0002\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nOptions for multiple wheel heights, including an option of a low base that allows passage under a stretcher with 2.5-inch clearance and an option of 3-inch wheels or larger.\nLiterature Review\nSC 2\nRequired to have an option for a scale that meets the full capacity of the lift.\nLiterature Review\nSC 3\nWeight capacity: 500 lbs. minimum.\nLiterature Review\nSC4\nLifting must be motorized/battery powered.\nLiterature Review\nSC 5\nLift must be tested in accordance with ISO 10535:2021\nLiterature Review\nSC 6\nLift must provide emergency stop and both electronic and manual emergency lowering.\nLiterature Review\nSC 7\nMust provide, or be compatible with, disposable, wipeable, and washable slings.\nLiterature Review\nSC8\nLift must be allowed to be used for ambulation.\nLiterature Review\nSC 9\nLegs adjustable to a minimum interior width to accommodate a chair.\nLiterature Review\nSC 10\nMax exterior width with legs closed 27.5 \nLiterature Review\nSC 11\nOption to charge using a second battery and a wall charger.\nLiterature Review\nSC 12\nLift must be allowed to be used with repositioning sling.\nLiterature Review\nSC 13\nLifting range that allow floor rescue and ambulation of patients up to 6 feet tall (hanger bar hooks can reach 24.5 inches or lower and 70 inches or higher).\nLiterature Review\nSC 14\nMust be FDA approved for marketing.\nLiterature Review\n\n\nApply to the following SC s to CLIN s 0003-0006\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 16\nAll Accessories must work with associated brand of lift\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer. \nCountry of Origin designation for all products\nAbility to provide uninterrupted supply of products on a national scale.\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. \nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","text":"DESCRIPTION\n\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Lifts: Patient Transfer: Floor: Loop Based product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.\nThe Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.\nThe SAC in conjunction with VHA is seeking a qualified source to provide EZ WayÂ® brand name or equal the Lifts: Patient Transfer: Floor: Loop Based on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Lifts: Patient Transfer: Floor: Loop Based to VA medical centers and facilities throughout the United States and its territories.\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113- Surgical Appliance and Supplies Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.\nSubmissions for this source sought shall be submitted by email no later than June 5th, 2025, at 4:30pm EST to all the following:\nJalima.Jones@va.gov\nSara.Vickroy@va.gov\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\n\nLifts: Patient: Transfer: Floor: Loop Based are designed for hoisting and transferring a patient safely and with minimal physical effort. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hooks to accommodate loop-based slings, and the lifting mechanism; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms. Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop.\nThe following Contract Line-Items Number (CLIN) are being considered:\nCLIN\n\nManufacturer\nPart Number\nDescription\n0001\nEZ Way\nL500PN-03\nLoop-based full-body patient lift with loop-based hanger bar, 500-pound capacity minimum.\n0002\nEZ Way\nL500PS-03\nOption for a Scale with the ability to lift with capacity equal to lift capacity.\n0003\nEZ Way\nLLB500PN\nLow base lift with option to fit under stretcher with 2.5-inch clearance.\n0004\nEZ Way\n11871\nBattery Replacement\n0005\nEZ Way\n11860\nWall Mount Battery Charger\n0006\nEZ Way\nCaster Option\nOptional Caster Sizes (Lift is available in optional 2\", 4\" or 5\" caster)\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide EZ WayÂ® brand name or equal Lifts: Patient Transfer: Floor: Loop Based as listed above or equal commodities which meet all the following salient characteristics (SCs):\nApply to the following SC s to CLINs 0001 0002\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nOptions for multiple wheel heights, including an option of a low base that allows passage under a stretcher with 2.5-inch clearance and an option of 3-inch wheels or larger.\nLiterature Review\nSC 2\nRequired to have an option for a scale that meets the full capacity of the lift.\nLiterature Review\nSC 3\nWeight capacity: 500 lbs. minimum.\nLiterature Review\nSC4\nLifting must be motorized/battery powered.\nLiterature Review\nSC 5\nLift must be tested in accordance with ISO 10535:2021\nLiterature Review\nSC 6\nLift must provide emergency stop and both electronic and manual emergency lowering.\nLiterature Review\nSC 7\nMust provide, or be compatible with, disposable, wipeable, and washable slings.\nLiterature Review\nSC8\nLift must be allowed to be used for ambulation.\nLiterature Review\nSC 9\nLegs adjustable to a minimum interior width to accommodate a chair.\nLiterature Review\nSC 10\nMax exterior width with legs closed 27.5\nLiterature Review\nSC 11\nOption to charge using a second battery and a wall charger.\nLiterature Review\nSC 12\nLift must be allowed to be used with repositioning sling.\nLiterature Review\nSC 13\nLifting range that allow floor rescue and ambulation of patients up to 6 feet tall (hanger bar hooks can reach 24.5 inches or lower and 70 inches or higher).\nLiterature Review\nSC 14\nMust be FDA approved for marketing.\nLiterature Review\n\nApply to the following SC s to CLIN s 0003-0006\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 16\nAll Accessories must work with associated brand of lift\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer.\nCountry of Origin designation for all products\nAbility to provide uninterrupted supply of products on a national scale.\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10G25Q0084","place_of_performance":{"street":"Nationwide"},"product_service_code":"6515"}],"due_at":"2025-06-10T20:30:00Z","due_date":"2025-06-10","closes_at":"2025-06-10T20:30:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-13T12:55:56.316659Z","principal_notice_id":"2c0067f7c38d411bab9b084549ccc249","description":{"text":"DESCRIPTION\n\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Lifts: Patient Transfer: Floor: Loop Based product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.\nThe Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.\nThe SAC in conjunction with VHA is seeking a qualified source to provide EZ WayÂ® brand name or equal the Lifts: Patient Transfer: Floor: Loop Based on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Lifts: Patient Transfer: Floor: Loop Based to VA medical centers and facilities throughout the United States and its territories.\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113- Surgical Appliance and Supplies Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.\nSubmissions for this source sought shall be submitted by email no later than June 5th, 2025, at 4:30pm EST to all the following:\nJalima.Jones@va.gov\nSara.Vickroy@va.gov\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\n\nLifts: Patient: Transfer: Floor: Loop Based are designed for hoisting and transferring a patient safely and with minimal physical effort. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hooks to accommodate loop-based slings, and the lifting mechanism; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms. Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop.\nThe following Contract Line-Items Number (CLIN) are being considered:\nCLIN\n\nManufacturer\nPart Number\nDescription\n0001\nEZ Way\nL500PN-03\nLoop-based full-body patient lift with loop-based hanger bar, 500-pound capacity minimum.\n0002\nEZ Way\nL500PS-03\nOption for a Scale with the ability to lift with capacity equal to lift capacity.\n0003\nEZ Way\nLLB500PN\nLow base lift with option to fit under stretcher with 2.5-inch clearance.\n0004\nEZ Way\n11871\nBattery Replacement\n0005\nEZ Way\n11860\nWall Mount Battery Charger\n0006\nEZ Way\nCaster Option\nOptional Caster Sizes (Lift is available in optional 2\", 4\" or 5\" caster)\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide EZ WayÂ® brand name or equal Lifts: Patient Transfer: Floor: Loop Based as listed above or equal commodities which meet all the following salient characteristics (SCs):\nApply to the following SC s to CLINs 0001 0002\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nOptions for multiple wheel heights, including an option of a low base that allows passage under a stretcher with 2.5-inch clearance and an option of 3-inch wheels or larger.\nLiterature Review\nSC 2\nRequired to have an option for a scale that meets the full capacity of the lift.\nLiterature Review\nSC 3\nWeight capacity: 500 lbs. minimum.\nLiterature Review\nSC4\nLifting must be motorized/battery powered.\nLiterature Review\nSC 5\nLift must be tested in accordance with ISO 10535:2021\nLiterature Review\nSC 6\nLift must provide emergency stop and both electronic and manual emergency lowering.\nLiterature Review\nSC 7\nMust provide, or be compatible with, disposable, wipeable, and washable slings.\nLiterature Review\nSC8\nLift must be allowed to be used for ambulation.\nLiterature Review\nSC 9\nLegs adjustable to a minimum interior width to accommodate a chair.\nLiterature Review\nSC 10\nMax exterior width with legs closed 27.5\nLiterature Review\nSC 11\nOption to charge using a second battery and a wall charger.\nLiterature Review\nSC 12\nLift must be allowed to be used with repositioning sling.\nLiterature Review\nSC 13\nLifting range that allow floor rescue and ambulation of patients up to 6 feet tall (hanger bar hooks can reach 24.5 inches or lower and 70 inches or higher).\nLiterature Review\nSC 14\nMust be FDA approved for marketing.\nLiterature Review\n\nApply to the following SC s to CLIN s 0003-0006\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 16\nAll Accessories must work with associated brand of lift\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No?\n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer.\nCountry of Origin designation for all products\nAbility to provide uninterrupted supply of products on a national scale.\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","html":"DESCRIPTION\n\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Lifts: Patient Transfer: Floor: Loop Based product line as a candidate for a VA-wide (otherwise referred to as  national ) single Requirements contract award.  \nThe Department of Veterans Affairs  (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. \nThe SAC in conjunction with VHA is seeking a qualified source to provide EZ WayÂ® brand name or equal the Lifts: Patient Transfer: Floor: Loop Based on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Lifts: Patient Transfer: Floor: Loop Based to VA medical centers and facilities throughout the United States and its territories. \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 339113- Surgical Appliance and Supplies Manufacturing, Product Service Code: 6515   Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that  All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation.  You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.\nSubmissions for this  source sought  shall be submitted by email no later than June 5th, 2025, at 4:30pm EST to all the following:\nJalima.Jones@va.gov\nSara.Vickroy@va.gov\n\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\n\nLifts: Patient: Transfer: Floor: Loop Based are designed for hoisting and transferring a patient safely and with minimal physical effort. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hooks to accommodate loop-based slings, and the lifting mechanism; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms.  Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop. \nThe following Contract Line-Items Number (CLIN) are being considered:\nCLIN\n\nManufacturer\nPart Number\nDescription\n0001\nEZ Way\nL500PN-03\nLoop-based full-body patient lift with loop-based hanger bar, 500-pound capacity minimum.\n0002\nEZ Way\nL500PS-03\nOption for a Scale with the ability to lift with capacity equal to lift capacity.\n0003\nEZ Way\nLLB500PN\nLow base lift with option to fit under stretcher with 2.5-inch clearance.\n0004\nEZ Way\n11871\nBattery Replacement\n0005\nEZ Way\n11860\nWall Mount Battery Charger\n0006\nEZ Way\nCaster Option\nOptional Caster Sizes (Lift is available in optional 2\", 4\" or 5\" caster)\n\nThe Department of Veterans Affairs (VA) is seeking vendors who can provide EZ WayÂ® brand name or equal Lifts: Patient Transfer: Floor: Loop Based as listed above or equal commodities which meet all the following salient characteristics (SCs):\nApply to the following SC s to CLINs 0001   0002\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nOptions for multiple wheel heights, including an option of a low base that allows passage under a stretcher with 2.5-inch clearance and an option of 3-inch wheels or larger.\nLiterature Review\nSC 2\nRequired to have an option for a scale that meets the full capacity of the lift.\nLiterature Review\nSC 3\nWeight capacity: 500 lbs. minimum.\nLiterature Review\nSC4\nLifting must be motorized/battery powered.\nLiterature Review\nSC 5\nLift must be tested in accordance with ISO 10535:2021\nLiterature Review\nSC 6\nLift must provide emergency stop and both electronic and manual emergency lowering.\nLiterature Review\nSC 7\nMust provide, or be compatible with, disposable, wipeable, and washable slings.\nLiterature Review\nSC8\nLift must be allowed to be used for ambulation.\nLiterature Review\nSC 9\nLegs adjustable to a minimum interior width to accommodate a chair.\nLiterature Review\nSC 10\nMax exterior width with legs closed 27.5 \nLiterature Review\nSC 11\nOption to charge using a second battery and a wall charger.\nLiterature Review\nSC 12\nLift must be allowed to be used with repositioning sling.\nLiterature Review\nSC 13\nLifting range that allow floor rescue and ambulation of patients up to 6 feet tall (hanger bar hooks can reach 24.5 inches or lower and 70 inches or higher).\nLiterature Review\nSC 14\nMust be FDA approved for marketing.\nLiterature Review\n\n\nApply to the following SC s to CLIN s 0003-0006\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 16\nAll Accessories must work with associated brand of lift\nLiterature Review\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\n\nResponses to this Sources Sought Notice shall include the following:\nDoes vendor offer an annual service plan, Yes or No? \n\nIf Yes:\nWhat does the plan cover?\nDoes plan cover software updates only?\nDoes the plan cover parts repair or replacement only?\nDoes the plan cover both software and parts?\n\nVendor are requested to provide documentation that shows information on their service plan.\n\nIs the service provided by the OEM or a subcontractor?\n\nFull name and address of company\nDUNS number/ CAGE Code/ SAM UIE\nBusiness Size\nManufacturer or Distributor\nIf distributor provide full name, business size and address of manufacturer. \nCountry of Origin designation for all products\nAbility to provide uninterrupted supply of products on a national scale.\nTechnical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. \nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"contacts":[{"name":"Jalima J. Jones","role":"primary","email":"Jalima.Jones@va.gov","title":"Contract Specialist"}],"place_of_performance":{"street":"Nationwide"},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"naics_codes":["339113"],"award":{"awardee":{}},"attachments":[{"resource_id":"74b4be1e9a534704a932d4590ff7fa71","name":"36C10G25Q0084.docx","kind":"file","mime_type":".docx","size_bytes":22276,"posted_at":"2025-05-28T20:10:14.747Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/74b4be1e9a534704a932d4590ff7fa71/download","mirrored":false},{"resource_id":"c854e3ffd07448b39cb13926e0755c1c","name":"VA | OALC | OPAL | SAC","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-05-28T20:10:14.747Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/opal/sac/index.asp","mirrored":false}],"awards":[],"related":[{"key":"36C10G27R0002","latest_notice_id":"f16ea5b6f90d4b3e903edd9b27a5c3aa","title":"6515--Patient Lifts and Slings for In Home Use","solicitation_number":"36C10G27R0002","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":4,"due_at":"2026-12-15T17:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"339113","psc":"6515","set_aside":"SBP","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open":[{"key":"N0010427QLA17","latest_notice_id":"5958ba02b5c94595a30747ebb8d1c461","title":"VALVE,BREATHING APP","solicitation_number":"N0010427QLA17","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-27T20:30:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"4240","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"IN THE SCHEDULE. ^^ \"ALL FREIGHT IS FOB ORIGIN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"N0010426QEJ19","latest_notice_id":"43eefc1812e24932a06b9e18e8f7e03b","title":"66--REAGENT POWDER","solicitation_number":"N0010426QEJ19","notice_type":"o","first_type":"o","first_posted":"2026-10-29","last_posted":"2026-10-29","notices":1,"due_at":"2026-11-30T20:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"},{"key":"N0010427QBB84","latest_notice_id":"34e1ae5135d948f0a44a6b0599aacab1","title":"REMOVABLE CONE,SPEC","solicitation_number":"N0010427QBB84","notice_type":"o","first_type":"o","first_posted":"2026-10-30","last_posted":"2026-10-30","notices":1,"due_at":"2026-11-30T20:30:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N00104","office_name":"NAVSUP WEAPON SYSTEMS SUPPORT MECH","naics":"339113","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-31T03:50:03.904859Z"}],"similar_open_total":20,"indexable":false}