{"canonical":"https://sealedbidder.com/opportunities/36c10g25q0075","key":"36C10G25Q0075","url":"https://sealedbidder.com/opportunities/36c10g25q0075","title":"6515--CANCELLATION: NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","solicitation_number":"36C10G25Q0075","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-04-07T16:00:00Z","first_posted":"2025-04-07","last_posted":"2025-04-07","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"334510","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d","title":"6515--NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","solicitation_number":"36C10G25Q0075","notice_type":"r","base_type":"r","posted":"2025-04-07","posted_at":"2025-04-07T15:14:58.270Z","due_at":"2025-04-21T20:30:00Z","due_date":"2025-04-21","cancelled":false,"archived":true,"archive_date":"2025-06-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2f99d5ef2c6449feb5dc6d7b0165cb0d/view","enriched":true,"history":[{"index":3,"title":"6515--CANCELLATION: NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-07T18:19:41.204Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e41f2aeaf7d44bd3944824a7b523903f","solicitation_number":"36C10G25Q0075","parent_opportunity_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d"},{"index":1,"title":"6515--NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-07T15:14:58.270Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d","solicitation_number":"36C10G25Q0075"}]},{"notice_id":"e41f2aeaf7d44bd3944824a7b523903f","title":"6515--CANCELLATION: NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","solicitation_number":"36C10G25Q0075","notice_type":"r","base_type":"r","posted":"2025-04-07","posted_at":"2025-04-07T18:19:41.204Z","due_at":"2025-04-07T16:00:00Z","due_date":"2025-04-07","cancelled":false,"archived":true,"archive_date":"2025-06-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e41f2aeaf7d44bd3944824a7b523903f/view","enriched":true,"history":[{"index":3,"title":"6515--CANCELLATION: NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-07T18:19:41.204Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e41f2aeaf7d44bd3944824a7b523903f","solicitation_number":"36C10G25Q0075","parent_opportunity_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d"},{"index":1,"title":"6515--NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-07T15:14:58.270Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d","solicitation_number":"36C10G25Q0075"}]}],"latest_notice_id":"e41f2aeaf7d44bd3944824a7b523903f","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-04-07","posted_at":"2025-04-07T15:14:58.270Z","created_at":"2025-04-07T15:14:56.053Z","modified_at":"2025-06-06T04:04:31.739Z","response_deadline":{"raw":"2025-04-21T16:30:00-04:00","utc":"2025-04-21T20:30:00Z","date":"2025-04-21","time":"16:30:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2f99d5ef2c6449feb5dc6d7b0165cb0d/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6515--NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","agency":{"office":{"code":"36C10G","name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"organization_id":"100167093","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-20","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--CANCELLATION: NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-07T18:19:41.204Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e41f2aeaf7d44bd3944824a7b523903f","solicitation_number":"36C10G25Q0075","parent_opportunity_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d"},{"index":1,"title":"6515--NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-07T15:14:58.270Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d","solicitation_number":"36C10G25Q0075"}],"contacts":[{"name":"Levi Russin","role":"primary","email":"Levi.Russin@va.gov","phone":"518-626-6757","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d","lineage_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T02:18:37.190392109Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"e6f783ce6914b72f194f2a4cefbef454f778aae985c0e713ffc371bc75eb2f4f","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T02:18:37.190392109Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"1.0 DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Cryotherapy System: Tissue Ablation - Endoscopic product line as a candidate for the Department of Veterans Affairs VA-wide (otherwise referred to as  national ) Non Expendable Equipment (NX) Requirements contract award.\nThe Department of Veterans Affairs  (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. \nThe SAC in conjunction with VHA is seeking a qualified source to provide VarianÂ® brand name or equal CryoCare Touch  Tissue Ablation System on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Cryotherapy System: Tissue Ablation - Endoscopic to VA medical centers and facilities throughout the United States. \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510   Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. The FAR Provision found at 52.204-7(b)(1) requires that  All interested Offerors must be registered in SAM prior to submitting an offer or proposal.  You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\nCryotherapy Tissue Ablation Systems are used for Cryoablation, a process that uses extreme cold (cryo) to destroy or damage tissue (ablation) whereby producing tissue necrosis at temperatures well below the freezing point of water (typically less than -20 degrees Celsius/-4 degrees Fahrenheit) using minimally invasive procedures. These systems typically consist of a central unit that provides the cryogen and includes electronic and mechanical components to perform and control the ablation; tubing to deliver the cryogen; and a probe (e.g., an applicator, needle, cannula, or catheter) to apply the cryogen directly or indirectly to the tissue. Ablation occurs when the cryogenic substance or cryogenic probe contacts the tissue. As the cells freeze, ice crystals form inside the cell and the subsequent cycle of freezing and thawing that follows actually destroys the tissue cells. Specifically, Cryotherapy System: Tissue Ablation - Endoscopic equipment are intended for use in open, minimally invasive or endoscopic surgical procedures in the areas of general surgery, urology, gynecology, oncology, neurology, dermatology, ENT, proctology, pulmonary surgery, and thoracic surgery for prostate and kidney tissue, liver metastases, tumors, skin lesions, and warts.\n\nThe following Contract Line Items are being considered:\nContract Line Item#\nBrand\nPart Number\nDescription\nBase Year\nOption Year I\nOption Year II\nOption Year III\nOption Year IV \n0001\nVarian, Inc.\nCRYO-38T\nCryoCare Touch  Tissue Ablation System (CryoCare Touch  Control Console, 15-inch LCD Touchscreen Monitor with folding Monitor Arm, Side Handles to facilitate mobility, Wheels with Wheel Locks, Power Supply, Argon Port (with Regulator and Supply Line), Helium Port (with Regulator and Supply Line), Cryoprobe Interface with eight (8) Cryoprobe Connections, TempProbe Interface with eight (8) TempProbe Connections, Alarm Audio Output on Back Panel, Remote Keypads, CryoCare Touch  System Software, and initial 1 YR Warranty)\n2\n2\n2\n2\n2\n0002\nVarian, Inc.\nCVA2400\nCryoprobe, Straight - Variable, 15 cm, 2.4 mm (8ft tubing)\n100\n100\n100\n100\n100\n0003\nVarian, Inc.\nCVA2400RA\nCryoprobe, V-Probe - Variable Right Angle, 15 cm, 2.4 mm (8ft tubing)\n100\n100\n100\n100\n100\n0004\nVarian, Inc.\nCVA2400RA-12\nCryoprobe, V-Probe - Variable Right Angle, 15 cm, 2.4 mm (12ft tubing)\n50\n50\n50\n50\n50\n0005\nVarian, Inc.\nPCS-17R\nCryoprobe, Right Angled Slimline, Round Ice, 15 cm, 1.7 mm\n100\n100\n100\n100\n100\n0006\nVarian, Inc.\nPCS-17RS\nCryoprobe, Right Angled Short Slimline, Round Ice, 7 cm, 1.7 mm\n50\n50\n50\n50\n50\n0007\nVarian, Inc.\nPCS-17\nCryoprobe, Right Angled Slimline, 15 cm, 1.7 mm\n100\n100\n100\n100\n100\n0008\nVarian, Inc.\nRS-17L\nCryoprobe, Right Angled Slimline, 20 cm, 1.7 mm\n50\n50\n50\n50\n50\n0009\nVarian, Inc.\nPCS-24\nCryoprobe, Right Angled Slimline, 15 cm, 2.4 mm\n50\n50\n50\n50\n50\n0010\nVarian, Inc.\nPCS-24L\nCryoprobe, Right Angled Long Slimline, 23 cm, 2.4 mm\n25\n25\n25\n25\n25\n0011\nVarian, Inc.\nR3.8\nCryoprobe, Right Angled, 13 cm, 3.8 mm\n20\n20\n20\n20\n20\n0012\nVarian, Inc.\nR3.8L\nCryoprobe, Right Angled Long, 28 cm, 3.8 mm\n20\n20\n20\n20\n20\n0013\nVarian, Inc.\nPC-2.1E\nCryoprobe, Isolis (Standard) Ellipsoidal, 15 cm, 2.1 mm\n20\n20\n20\n20\n20\n0014\nVarian, Inc.\nPC-2.1EL\nCryoprobe, Isolis (Long) Ellipsoidal 20 cm, 2.1 mm\n20\n20\n20\n20\n20\n0015\nVarian, Inc.\nPC-2.1S\nCryoprobe, Isolis (Standard) Spherical 15 cm, 2.1 mm\n20\n20\n20\n20\n20\n0016\nVarian, Inc.\nPC-2.1SL\nCryoprobe, Isolis (Long) Spherical 20 cm, 2.1 mm\n20\n20\n20\n20\n20\n0017\nVarian, Inc.\nCRYO-48-F\nCryoprobe, 29 cm, 8 mm\n20\n20\n20\n20\n20\n0018\nVarian, Inc.\nCRYO-55-F\nTempProbe Short (for Direct Placement), 14.6 cm, 16 ga\n250\n250\n250\n250\n250\n0019\nVarian, Inc.\nCRYO-204V\nCryoablation Procedure Kit   Variable (4 x CVA2400, 4 x Cryo-55F, 1 x Cryo-77)\n25\n25\n25\n25\n25\n0020\nVarian, Inc.\nCRYO-207V\nCryoablation Procedure Kit   Variable (6 x CVA2400, 6 x Cryo-55F, 1 x Cryo-77)\n25\n25\n25\n25\n25\n0021\nVarian, Inc.\nDP35-0551-111\nRegulator, 1700 PSI with Filter\n1\n1\n1\n1\n1\n0022\nVarian, Inc.\nDP35-0551-112\nRegulator, 3100 PSI with Filter\n1\n1\n1\n1\n1\n0023\nVarian, Inc.\nDP35-0551-905\nHelium Regulator with Relief Valve\n1\n1\n1\n1\n1\n0024\nVarian, Inc.\nDP35-0551-906\nHelium Supply Hose\n1\n1\n1\n1\n1\n0025\nVarian, Inc.\nDP35-0551-907\nArgon Regulator with Relief Valve\n1\n1\n1\n1\n1\n0026\nVarian, Inc.\nDP35-0551-908\nArgon Regulator without Relief Valve\n1\n1\n1\n1\n1\n0027\nVarian, Inc.\nDP35-0551-909\nArgon Supply Hose\n1\n1\n1\n1\n1\n0028\nVarian, Inc.\nCRYO-77\nUretheral Warming Catheter\n50\n50\n50\n50\n50\n0029\nVarian, Inc.\nCRYO-EQ\nCryoablation Equipment Rental (per case if required)\n25\n25\n25\n25\n25\n0030\nVarian, Inc.\nCRYO-SVC\nTechnical Support Services Fee (per case, if needed)\n25\n25\n25\n25\n25\n0031\nVarian, Inc.\nCRYO-WARR\n(1) One Year Warranty and Service Maintenance for CryoCare Touch  with Annual On-Site Preventative Maintenance Service.\n10\n10\n10\n10\n10\n\nThe VA is seeking vendors who can provide Varian Medical SystemsÂ® CryoCare Touch  Tissue Ablation System or equal as listed above which meet all the following salient characteristics:\nCLIN 0001 applies to SCs 1-5\nCLINs 0002-0020 applies to SC 6\nCLIN 0031 applies to SC 8\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nMust provide high quality cryoablation treatment to efficiently ablate liver, prostate, kidney, and other soft tissue and tumors\nLiterature Review\nSC 2\nMust have a user-friendly / intuitive touchscreen user interface with integrated temperature, power, and timer to monitor, display, and control therapy duration\nLiterature Review\nSC 3\nMust provide audible and visual alarms and warnings\nLiterature Review\nSC 4\nMust include a dedicated mobile system or console cart, easy to roll with adequate space for components and tanks. Cart must have locking casters\nLiterature Review\nSC 5\nMust use a medical grade power cord and use standard electrical wall outlet - 110V-120V circuit, 120V 60Hz AC input\nLiterature Review\nSC 6\nMust provide probes / applicators / needles of various lengths including equal to or longer than 23 cm with a quick release and connect capability\nLiterature Review\nSC 7\nMust be FDA approved. Must demonstrate compliance with requirements of widely accepted product safety standards, as determined through independent testing by organizations such as the American National Standards Institute (ANSI), Underwriters Laboratories (UL), American Section of the International Association for Testing Materials, and International Electrotechnical Commission (IEC)\nLiterature Review\nSC 8\nManufacturer Warranties - should outline any length and coverage of warranties/guarantees associated with their products, as these can provide assurance of quality and reliability to the government\nLiterature Review\n\nEvaluation Sub-factors:\n\nSafety   All safety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nPower and Temperature Sensors\nProbe/Applicator/Needle Power Settings for Ice Formation Control\n\nDesign   All design features and functions of the offered device will be evaluated. Areas may include but are not limited to the following:\nCentralized Control / Consolidated Touchscreen User Interface\nAvailability of Various Probe/Applicator/Needle Sizes (length and gauged thickness)\nSupports the Simultaneous use of Multiple Probes/Applicators/Needles\nCryo/Cooling System\nAvailability of Distal Energy Control and  Ice-Ball  Formation\nCapable of Storing/Retrieving Case Logs\nSpace Requirements / Footprint\n\nPerformance   Device will be evaluated for its ability to perform its intended function. Areas may include but are not limited to:\nSystem Cart Mobility and Functionality\nEase of Use / Streamlined Workflow\nAbility to be Sanitized Using Hospital Approved Disinfectants/Cleaners\n\nQuality/Construction   All aspects of construction and quality of material of the device will be evaluated. Areas may include but are not limited to the following:\nLife Span / Durability\nTraining\nService Program\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above. \nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nFull name and address of company;\nUnique Entity Identifier (UEI) number;\nBusiness Size;\nManufacturer or Distributor;\nIf distributor provide full name, business size and address of manufacturer.\nCountry of Origin designation for all products;\nAbility to provide uninterrupted supply of products on a national scale;\nTechnical Literature that clearly shows product(s) meet the identified SCs (if submitting an  or-equal  item);\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","text":"1.0 DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Cryotherapy System: Tissue Ablation - Endoscopic product line as a candidate for the Department of Veterans Affairs VA-wide (otherwise referred to as national ) Non Expendable Equipment (NX) Requirements contract award.\nThe Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.\nThe SAC in conjunction with VHA is seeking a qualified source to provide VarianÂ® brand name or equal CryoCare Touch Tissue Ablation System on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Cryotherapy System: Tissue Ablation - Endoscopic to VA medical centers and facilities throughout the United States.\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Electrotherapeutic Apparatus Manufacturing and the associated size standard is 1,250 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\nCryotherapy Tissue Ablation Systems are used for Cryoablation, a process that uses extreme cold (cryo) to destroy or damage tissue (ablation) whereby producing tissue necrosis at temperatures well below the freezing point of water (typically less than -20 degrees Celsius/-4 degrees Fahrenheit) using minimally invasive procedures. These systems typically consist of a central unit that provides the cryogen and includes electronic and mechanical components to perform and control the ablation; tubing to deliver the cryogen; and a probe (e.g., an applicator, needle, cannula, or catheter) to apply the cryogen directly or indirectly to the tissue. Ablation occurs when the cryogenic substance or cryogenic probe contacts the tissue. As the cells freeze, ice crystals form inside the cell and the subsequent cycle of freezing and thawing that follows actually destroys the tissue cells. Specifically, Cryotherapy System: Tissue Ablation - Endoscopic equipment are intended for use in open, minimally invasive or endoscopic surgical procedures in the areas of general surgery, urology, gynecology, oncology, neurology, dermatology, ENT, proctology, pulmonary surgery, and thoracic surgery for prostate and kidney tissue, liver metastases, tumors, skin lesions, and warts.\n\nThe following Contract Line Items are being considered:\nContract Line Item#\nBrand\nPart Number\nDescription\nBase Year\nOption Year I\nOption Year II\nOption Year III\nOption Year IV\n0001\nVarian, Inc.\nCRYO-38T\nCryoCare Touch Tissue Ablation System (CryoCare Touch Control Console, 15-inch LCD Touchscreen Monitor with folding Monitor Arm, Side Handles to facilitate mobility, Wheels with Wheel Locks, Power Supply, Argon Port (with Regulator and Supply Line), Helium Port (with Regulator and Supply Line), Cryoprobe Interface with eight (8) Cryoprobe Connections, TempProbe Interface with eight (8) TempProbe Connections, Alarm Audio Output on Back Panel, Remote Keypads, CryoCare Touch System Software, and initial 1 YR Warranty)\n2\n2\n2\n2\n2\n0002\nVarian, Inc.\nCVA2400\nCryoprobe, Straight - Variable, 15 cm, 2.4 mm (8ft tubing)\n100\n100\n100\n100\n100\n0003\nVarian, Inc.\nCVA2400RA\nCryoprobe, V-Probe - Variable Right Angle, 15 cm, 2.4 mm (8ft tubing)\n100\n100\n100\n100\n100\n0004\nVarian, Inc.\nCVA2400RA-12\nCryoprobe, V-Probe - Variable Right Angle, 15 cm, 2.4 mm (12ft tubing)\n50\n50\n50\n50\n50\n0005\nVarian, Inc.\nPCS-17R\nCryoprobe, Right Angled Slimline, Round Ice, 15 cm, 1.7 mm\n100\n100\n100\n100\n100\n0006\nVarian, Inc.\nPCS-17RS\nCryoprobe, Right Angled Short Slimline, Round Ice, 7 cm, 1.7 mm\n50\n50\n50\n50\n50\n0007\nVarian, Inc.\nPCS-17\nCryoprobe, Right Angled Slimline, 15 cm, 1.7 mm\n100\n100\n100\n100\n100\n0008\nVarian, Inc.\nRS-17L\nCryoprobe, Right Angled Slimline, 20 cm, 1.7 mm\n50\n50\n50\n50\n50\n0009\nVarian, Inc.\nPCS-24\nCryoprobe, Right Angled Slimline, 15 cm, 2.4 mm\n50\n50\n50\n50\n50\n0010\nVarian, Inc.\nPCS-24L\nCryoprobe, Right Angled Long Slimline, 23 cm, 2.4 mm\n25\n25\n25\n25\n25\n0011\nVarian, Inc.\nR3.8\nCryoprobe, Right Angled, 13 cm, 3.8 mm\n20\n20\n20\n20\n20\n0012\nVarian, Inc.\nR3.8L\nCryoprobe, Right Angled Long, 28 cm, 3.8 mm\n20\n20\n20\n20\n20\n0013\nVarian, Inc.\nPC-2.1E\nCryoprobe, Isolis (Standard) Ellipsoidal, 15 cm, 2.1 mm\n20\n20\n20\n20\n20\n0014\nVarian, Inc.\nPC-2.1EL\nCryoprobe, Isolis (Long) Ellipsoidal 20 cm, 2.1 mm\n20\n20\n20\n20\n20\n0015\nVarian, Inc.\nPC-2.1S\nCryoprobe, Isolis (Standard) Spherical 15 cm, 2.1 mm\n20\n20\n20\n20\n20\n0016\nVarian, Inc.\nPC-2.1SL\nCryoprobe, Isolis (Long) Spherical 20 cm, 2.1 mm\n20\n20\n20\n20\n20\n0017\nVarian, Inc.\nCRYO-48-F\nCryoprobe, 29 cm, 8 mm\n20\n20\n20\n20\n20\n0018\nVarian, Inc.\nCRYO-55-F\nTempProbe Short (for Direct Placement), 14.6 cm, 16 ga\n250\n250\n250\n250\n250\n0019\nVarian, Inc.\nCRYO-204V\nCryoablation Procedure Kit Variable (4 x CVA2400, 4 x Cryo-55F, 1 x Cryo-77)\n25\n25\n25\n25\n25\n0020\nVarian, Inc.\nCRYO-207V\nCryoablation Procedure Kit Variable (6 x CVA2400, 6 x Cryo-55F, 1 x Cryo-77)\n25\n25\n25\n25\n25\n0021\nVarian, Inc.\nDP35-0551-111\nRegulator, 1700 PSI with Filter\n1\n1\n1\n1\n1\n0022\nVarian, Inc.\nDP35-0551-112\nRegulator, 3100 PSI with Filter\n1\n1\n1\n1\n1\n0023\nVarian, Inc.\nDP35-0551-905\nHelium Regulator with Relief Valve\n1\n1\n1\n1\n1\n0024\nVarian, Inc.\nDP35-0551-906\nHelium Supply Hose\n1\n1\n1\n1\n1\n0025\nVarian, Inc.\nDP35-0551-907\nArgon Regulator with Relief Valve\n1\n1\n1\n1\n1\n0026\nVarian, Inc.\nDP35-0551-908\nArgon Regulator without Relief Valve\n1\n1\n1\n1\n1\n0027\nVarian, Inc.\nDP35-0551-909\nArgon Supply Hose\n1\n1\n1\n1\n1\n0028\nVarian, Inc.\nCRYO-77\nUretheral Warming Catheter\n50\n50\n50\n50\n50\n0029\nVarian, Inc.\nCRYO-EQ\nCryoablation Equipment Rental (per case if required)\n25\n25\n25\n25\n25\n0030\nVarian, Inc.\nCRYO-SVC\nTechnical Support Services Fee (per case, if needed)\n25\n25\n25\n25\n25\n0031\nVarian, Inc.\nCRYO-WARR\n(1) One Year Warranty and Service Maintenance for CryoCare Touch with Annual On-Site Preventative Maintenance Service.\n10\n10\n10\n10\n10\n\nThe VA is seeking vendors who can provide Varian Medical SystemsÂ® CryoCare Touch Tissue Ablation System or equal as listed above which meet all the following salient characteristics:\nCLIN 0001 applies to SCs 1-5\nCLINs 0002-0020 applies to SC 6\nCLIN 0031 applies to SC 8\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nMust provide high quality cryoablation treatment to efficiently ablate liver, prostate, kidney, and other soft tissue and tumors\nLiterature Review\nSC 2\nMust have a user-friendly / intuitive touchscreen user interface with integrated temperature, power, and timer to monitor, display, and control therapy duration\nLiterature Review\nSC 3\nMust provide audible and visual alarms and warnings\nLiterature Review\nSC 4\nMust include a dedicated mobile system or console cart, easy to roll with adequate space for components and tanks. Cart must have locking casters\nLiterature Review\nSC 5\nMust use a medical grade power cord and use standard electrical wall outlet - 110V-120V circuit, 120V 60Hz AC input\nLiterature Review\nSC 6\nMust provide probes / applicators / needles of various lengths including equal to or longer than 23 cm with a quick release and connect capability\nLiterature Review\nSC 7\nMust be FDA approved. Must demonstrate compliance with requirements of widely accepted product safety standards, as determined through independent testing by organizations such as the American National Standards Institute (ANSI), Underwriters Laboratories (UL), American Section of the International Association for Testing Materials, and International Electrotechnical Commission (IEC)\nLiterature Review\nSC 8\nManufacturer Warranties - should outline any length and coverage of warranties/guarantees associated with their products, as these can provide assurance of quality and reliability to the government\nLiterature Review\n\nEvaluation Sub-factors:\n\nSafety All safety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nPower and Temperature Sensors\nProbe/Applicator/Needle Power Settings for Ice Formation Control\n\nDesign All design features and functions of the offered device will be evaluated. Areas may include but are not limited to the following:\nCentralized Control / Consolidated Touchscreen User Interface\nAvailability of Various Probe/Applicator/Needle Sizes (length and gauged thickness)\nSupports the Simultaneous use of Multiple Probes/Applicators/Needles\nCryo/Cooling System\nAvailability of Distal Energy Control and Ice-Ball Formation\nCapable of Storing/Retrieving Case Logs\nSpace Requirements / Footprint\n\nPerformance Device will be evaluated for its ability to perform its intended function. Areas may include but are not limited to:\nSystem Cart Mobility and Functionality\nEase of Use / Streamlined Workflow\nAbility to be Sanitized Using Hospital Approved Disinfectants/Cleaners\n\nQuality/Construction All aspects of construction and quality of material of the device will be evaluated. Areas may include but are not limited to the following:\nLife Span / Durability\nTraining\nService Program\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nFull name and address of company;\nUnique Entity Identifier (UEI) number;\nBusiness Size;\nManufacturer or Distributor;\nIf distributor provide full name, business size and address of manufacturer.\nCountry of Origin designation for all products;\nAbility to provide uninterrupted supply of products on a national scale;\nTechnical Literature that clearly shows product(s) meet the identified SCs (if submitting an or-equal item);\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10G25Q0075","place_of_performance":{"street":"Enterprise-wide","country":{"name":"CONUS and OCONUS"}},"product_service_code":"6515"},{"award":{"awardee":{}},"dates":{"posted":"2025-04-07","posted_at":"2025-04-07T18:19:41.204Z","created_at":"2025-04-07T18:19:38.909Z","modified_at":"2025-06-06T04:04:31.739Z","response_deadline":{"raw":"2025-04-07T12:00:00-04:00","utc":"2025-04-07T16:00:00Z","date":"2025-04-07","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e41f2aeaf7d44bd3944824a7b523903f/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6515--CANCELLATION: NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","agency":{"office":{"code":"36C10G","name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"organization_id":"100167093","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-06-06","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--CANCELLATION: NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-07T18:19:41.204Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"e41f2aeaf7d44bd3944824a7b523903f","solicitation_number":"36C10G25Q0075","parent_opportunity_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d"},{"index":1,"title":"6515--NX EQ Cryotherapy System: Tissue Ablation - Endoscopic","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-07T15:14:58.270Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d","solicitation_number":"36C10G25Q0075"}],"contacts":[{"name":"Levi Russin","role":"primary","email":"Levi.Russin@va.gov","phone":"518-626-6757","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"e41f2aeaf7d44bd3944824a7b523903f","lineage_id":"2f99d5ef2c6449feb5dc6d7b0165cb0d","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-19T02:46:20.154702239Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"b25da1c5a16d90868eb1093b7519487918564be32e589d5a3519f68da7e77da5","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-19T02:46:20.154702239Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"The purpose of this Amendment 0001 to the Sources Sought RFI posted to Contract Opportunities under RFI 36C10G25Q0075 is to cancel the RFI Sources Sought.\n\n36C10G25Q0075 is cancelled. Responses will not be accepted or considered for market research purposes.","text":"The purpose of this Amendment 0001 to the Sources Sought RFI posted to Contract Opportunities under RFI 36C10G25Q0075 is to cancel the RFI Sources Sought.\n\n36C10G25Q0075 is cancelled. Responses will not be accepted or considered for market research purposes.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10G25Q0075","place_of_performance":{"street":"Enterprise-wide","country":{"name":"CONUS and OCONUS"}},"product_service_code":"6515"}],"due_at":"2025-04-07T16:00:00Z","due_date":"2025-04-07","closes_at":"2025-04-07T16:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":true,"archived":true,"updated_at":"2026-11-20T00:59:51.738993Z","principal_notice_id":"e41f2aeaf7d44bd3944824a7b523903f","description":{"text":"The purpose of this Amendment 0001 to the Sources Sought RFI posted to Contract Opportunities under RFI 36C10G25Q0075 is to cancel the RFI Sources Sought.\n\n36C10G25Q0075 is cancelled. Responses will not be accepted or considered for market research purposes.","html":"The purpose of this Amendment 0001 to the Sources Sought RFI posted to Contract Opportunities under RFI 36C10G25Q0075 is to cancel the RFI Sources Sought.\n\n36C10G25Q0075 is cancelled. Responses will not be accepted or considered for market research purposes.","origin":"detail"},"contacts":[{"name":"Levi Russin","role":"primary","email":"Levi.Russin@va.gov","phone":"518-626-6757","title":"Contract Specialist"}],"place_of_performance":{"street":"Enterprise-wide","country":{"name":"CONUS and OCONUS"}},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"naics_codes":["334510"],"award":{"awardee":{}},"attachments":[{"resource_id":"595e46bf9b23495d8abff08092ba93a7","name":"36C10G25Q0075.docx","kind":"file","mime_type":".docx","size_bytes":29045,"posted_at":"2025-04-07T15:14:58.270Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/595e46bf9b23495d8abff08092ba93a7/download","mirrored":false},{"resource_id":"fc16ffa29b244db6b4abe2fb682d258c","name":"To learn more about SAC and its mission, please click here","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-04-07T15:14:58.270Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/opal/sac/index.asp","mirrored":false},{"resource_id":"56765f6801df4536a8c39ad3971a3d6b","name":"36C10G25Q0075 0001.docx","kind":"file","mime_type":".docx","size_bytes":14567,"posted_at":"2025-04-07T18:19:41.204Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/56765f6801df4536a8c39ad3971a3d6b/download","mirrored":false}],"awards":[],"related":[{"key":"36C10G27R0002","latest_notice_id":"f16ea5b6f90d4b3e903edd9b27a5c3aa","title":"6515--Patient Lifts and Slings for In Home Use","solicitation_number":"36C10G27R0002","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":4,"due_at":"2026-12-15T17:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"339113","psc":"6515","set_aside":"SBP","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open":[{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C10X27R0005","latest_notice_id":"e932ae7c1a2641ef910a7fa47204c74e","title":"6515--NX EQ Ultrasonic Aspirator System: Tissue Ablation (VA-27-00010132)","solicitation_number":"36C10X27R0005","notice_type":"k","first_type":"k","first_posted":"2026-11-09","last_posted":"2026-11-18","notices":3,"due_at":"2026-12-01T15:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C10X27Q0033","latest_notice_id":"2bf06c09e95d4059b2bdae0c88e09c15","title":"6515--Copy of NX EQ Thulium Fiber Laser (VA-27-00003102)","solicitation_number":"36C10X27Q0033","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-11T04:59:00Z","due_date":"2026-12-10","closes_at":"2026-12-11T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":11,"indexable":false}