Skip to content

SealedBidder is a private company, not a government agency.

Sign upDashboard
  • 8,692 federal solicitations are open right now. How many of them are yours?
  • New solicitations are posted every day. The ones you never saw are the ones you cannot win.
  • Stop checking SAM.gov every morning. Let the contracts that fit your business come to you.
  • Tell SealedBidder what you sell in one sentence. AI reads every open solicitation for you.
  • Deadlines are short. Hear about a solicitation the day it is posted, not the week it closes.
  • Amendments move deadlines. Watch a solicitation and SealedBidder tells you when it changes.
  • See which contracts in your field are about to end, and who holds them today.
  • Plans from $39 a month. See your matches before you pay.
See plans

Sources sought

NX EQ Ophthalmic Perimeters

36C10G25Q0070

Department of Veterans Affairs, Strategic Acquisition Center Fredericksburg. Surgical and Medical Instrument Manufacturing.

Response deadline

April 10, 2025 at 9:00 AM EDT

Closed 595 days ago. Posted March 28, 2025. Scheduled to archive April 25, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

14 like it are open now in surgical and medical instrument manufacturing

All 14 open in surgical and medical instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 339112 (surgical and medical instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of March 28, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

1.0 DESCRIPTION

THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs’ (VA) Strategic Acquisition Center (SAC) is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) as a means of conducting market research to identify qualified sources with the capability and the resources to meet the Veterans Health Administration’s (VHA) Non-Expendable Equipment National Program requirement for Ophthalmic Perimeters.

The SAC in conjunction with VHA is seeking a qualified source to supply brand name or equal Zeiss Humphrey® Field Analyzer 3 (HFA3) and associated equipment on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Ophthalmic Perimeters to VA medical centers and facilities throughout the United States.

The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.

The associated North American Industrial Classification System (NAICS) code for this procurement is 339112 – Surgical and Medical Instrument Manufacturing, Product Service Code: 6515 – Medical and Surgical Instruments, Equipment, and Supplies.

Manufacturing and the associated size standard is1,000 employees.

The FAR Provision found at 52.204-7(b)(1) requires that “All interested Offerors must be registered in SAM prior to submitting an offer or quotation.” You may access the SAM website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of submission.

Submissions for this “sources sought” shall be submitted by email no later than April 10, 2024, at 9:00am EST to all the following:

Alex.Beck1@va.gov

Sara.Vickroy@va.gov

This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.

2.0 SCOPE OF WORK

The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Ophthalmic Perimeters product line as a candidate for a VA-wide (otherwise referred to as “national”) single Requirements contract award.

The Zeiss Humphrey® Field Analyzer 3 (HFA3) (Ophthalmic Perimeters ) or equal are electronic ophthalmic instruments designed to measure the quality and quantity of central and peripheral vision, which is the visual field. The device measures and records the visual field one eye at a time by projecting a light stimulus in a field that extends approximately 60-110 degrees, in all directions.  Once the test is completed, the perimetry device converts the visual stimuli to a topography-like grayscale map that allows the ophthalmologist to see areas of normal vision, mildly depressed vision, and areas of severe depressed vision. These devices are used to diagnose and monitor diseases such as glaucoma and brain strokes.

The Contractor must demonstrate the ability to meet all requirements for the solicitation. The objective is to provide Ophthalmic Perimeters to be used by clinicians throughout the VA medical centers and facilities. The period of performance is for a base of 12-months with four 12-month option periods.

The following Contract Line Items are being considered:

Contract Line Items

Manufacturer

Part Number

Description

0001

Zeiss

MFA3 860

Humphrey Field Analyzer 3

0002

Zeiss

Installation

Installation and initial training

0003

Zeiss

OPTIME Prevent

Service Agreement Prevent

0004

Zeiss

OPTIME Advanced

Service Agreement Advanced

0005

Zeiss

OPTIME Complete

Service Agreement Complete

The Department of Veterans Affairs (VA) is seeking vendors who can provide Zeiss Humphrey® Field Analyzer 3 (HFA3) (Ophthalmic Perimeters ) as listed above or equal commodities which meet all the following salient characteristics.

CLIN 0001 applies to the Following SCs:

SC #

SALIENT CHARACTERISTICS

Method of Evaluation

SC 1

Must have automated eye tracking

Literature Review

SC 2

Must have temporal range of 90 degrees each eye

Literature Review

SC 3

Must have multiple Fixation Control options.

Literature Review

SC 4

Must be capable of static perimetry

Literature Review

SC 5

Must be capable of kinetic perimetry

Literature Review

SC 6

Must perform multiple testing strategies

Literature Review

SC 7

Must provide progression analysis using trend patterns

Literature Review

SC 8

Must provide ability to view HFA-style reports.

Literature Review

SC 9

Must have ability to provide a minimum of these visual stimuli: white on white; red/blue on white; blue on yellow

Literature Review

SC 10

Must be DICOM compatible.

Literature Review

SC 11

Must provide at least one year warranty

For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics (SC) specified above.

The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the OEM and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.

Responses to this Sources Sought Notice shall include the following:

  1. Does vendor offer an annual service plan, Yes or No?

    1. If Yes:
      1. What does the plan cover?
      2. Does plan cover software updates only?
      3. Does the plan cover parts repair or replacement only?
      4. Does the plan cover both software and parts?

    1. Vendor is requested to provide documentation that shows information on their service plan.

    1. Is the service provided by the OEM or a subcontractor?

  1. Full name and address of company
  2. DUNS number/ CAGE Code/ SAM UIE
  3. Business Size
  4. Manufacturer or Distributor
    1. If distributor provide full name, business size and address of manufacturer.
  5. Country of Origin designation for all products
  6. Ability to provide uninterrupted supply of products on a national scale
  7. Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met
  8. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.

Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.

Contractors submitting capability statements in response to this RFI must specifically address the questions outlined above. Generic capability statements that do not directly pertain to this RFI will not be considered. Additionally, links requesting capability statements or further information will not be accessed. All responses must be submitted as an actual file attachment.

Attachments

Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. March 28, 2025

    Sources sought

    Due April 10, 2025 at 9:00 AM EDT. SAM.gov, notice 47ae77e661cd487daa592ac999dac557

    1 revision on SAM
    • March 28, 2025: publish, sources sought

Points of contact