Sources sought

NX EQ Lift: Patient Transfer: Clip Based Standard

36C10G25Q0066

Department of Veterans Affairs, Strategic Acquisition Center Fredericksburg. Surgical Appliance and Supplies Manufacturing.

Response deadline

March 28, 2025 at 4:30 AM EDT

Closed 608 days ago. Posted March 20, 2025. Scheduled to archive July 5, 2025.

Get the next one like this from Department of Veterans Affairs by email, the day it is posted.Find my opportunities

This one closed in 2025

20 like it are open now in surgical appliance and supplies manufacturing

  • VALVE,BREATHING APP

    Department of the Navy, NAVSUP Weapon Systems Support Mech

    SolicitationNAICS 339113Ship to the buyerN0010427QLA17
    Due tomorrowNov 27
  • REAGENT POWDER

    Department of the Navy, NAVSUP Weapon Systems Support Mech

    SolicitationNAICS 339113Ship to the buyerN0010426QEJ19
    Due in 4 daysNov 30
  • REMOVABLE CONE,SPEC

    Department of the Navy, NAVSUP Weapon Systems Support Mech

    SolicitationNAICS 339113Ship to the buyerN0010427QBB84
    Due in 4 daysNov 30

All 20 open in surgical appliance and supplies manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 339113 (surgical appliance and supplies manufacturing), means no more than 800 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of March 20, 2025. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

DESCRIPTION The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Lifts: Patient Transfer: Clip Based Standard product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award. The Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. The SAC in conjunction with VHA is seeking a qualified source to provide Arjo Maxi Move® brand name or equal the Lifts: Patient Transfer: Clip Based Standard on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Lifts: Patient Transfer: Clip Based Standard to VA medical centers and facilities throughout the United States and its territories. The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation. The associated North American Industrial Classification System (NAICS) code for this procurement is 339113- Surgical Appliance and Supplies Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission. This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. 2.0 SCOPE Lifts: Patient Transfer: Clip Based Standard are Lifts designed for hoisting and transferring a patient safely and with minimal physical effort. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a seat (sling or rigid), and the lifting mechanism; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms. Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop. Some patient transfer lifts are mounted on tracks to permit patient transfers between rooms or different vertical levels. Lifts may also be designed to include a horizontal platform that is placed on the floor to raise a patient from the floor to standing or sitting position. These units are usually mobile, and battery powered. The following Contract Line-Items Numbers (CLINs) are being considered: CLIN Part Number Description BASE YEAR YEAR 1 YEAR 2 YEAR 3 YEAR 4 0001 KMCEUN MAXI MOVE, DPS, SCALE, X L-HEIGHT 50 50 50 50 50 0002 KMCEUN-D MAXI MOVE EXTRA LOW CHASSIS SCALE 50 50 50 50 50 0003 KMCEXN MAXI MOVE DPS EXTRA LOW HEIGHT 50 50 50 50 50 0004 KMCEXN-D MAXI MOVE COMBI EXTRA LOW CHASSIS 50 50 50 50 50 0005 KMCLUN MAXI MOVE, SCALE, L HEIGHT -UL 50 50 50 50 50 0006 KMCLUN-D MAXI MOVE, DPS, SCALE, L-HEIGHT 50 50 50 50 50 0007 KMCLXN MAXI MOVE COMBI LOW CHASSIS 50 50 50 50 50 0008 KMCLXN-D MAXI MOVE COMBI LOW CHASSIS 50 50 50 50 50 0009 700-19326-BOX TWO POINT SPREADER BAR 50 50 50 50 50 0010 700-19331-BOX FOUR POINT SPREADER BAR 50 50 50 50 50 0011 700-19311-BOX POWERED DPS SPREADER BAR, MEDIUM 50 50 50 50 50 0012 700-19316-BOX POWERED DPS SPREADER BAR, LARGE 50 50 50 50 50 0013 MFA1000M-S-L1 DISPOSABLE CLIP SLING, SMALL 50 50 50 50 50 0014 MFA1000M-M-L1 DISPOSABLE CLIP SLING, MEDIUM 75 75 75 75 75 0015 MFA1000M-L-L1 DISPOSABLE CLIP SLING, LARGE 75 75 75 75 75 0016 MFA1000M-LL-L1 DISPOSABLE CLIP SLING, LARGE LONG 75 75 75 75 75 0017 MFA1000M-XL-L1 DISPOSABLE CLIP SLING, X-LARGE 75 75 75 75 75 0018 MFA1000M-XXL-L1 DISPOSABLE CLIP SLING, XX-LARGE 75 75 75 75 75 0019 MFA2100-S-L1 DISPOSABLE LOOP SLING, SMALL 50 50 50 50 50 0020 MFA2100-M-L1 DISPOSABLE LOOP SLING, MEDIUM 50 50 50 50 50 0021 MFA2100-L-L1 DISPOSABLE LOOP SLING, LARGE 75 75 75 75 75 0022 MFA2100-XL-L1 DISPOSABLE LOOP SLING, X-LARGE 75 75 75 75 75 0023 MFA2100-XXL-L1 DISPOSABLE LOOP SLING, XX-LARGE 75 75 75 75 75 0024 MAA4000M-XS-L1 LAUNDERABLE CLIP SLING, X-SMALL 50 50 50 50 50 0025 MAA4000M-S-L1 LAUNDERABLE CLIP SLING, SMALL 50 50 50 50 50 0026 MAA4000M-M-L1 LAUNDERABLE CLIP SLING, MEDIUM 75 75 75 75 75 0027 MAA4000M-L-L1 LAUNDERABLE CLIP SLING, LARGE 75 75 75 75 75 0028 MAA4000M-LL-L1 LAUNDERABLE CLIP SLING, LARGE LONG 75 75 75 75 75 0029 MAA4000M-XL-L1 LAUNDERABLE CLIP SLING, X-LARGE 75 75 75 75 75 0030 MAA4000M-XXL-L1 LAUNDERABLE CLIP SLING, XX-LARGE 75 75 75 75 75 0031 MLA2000-S-L1 LAUNDERABLE LOOP SLING, SMALL 50 50 50 50 50 0032 MLA2000-M-L1 LAUNDERABLE LOOP SLING, MEDIUM 50 50 50 50 50 0033 MLA2000-L-L1 LAUNDERABLE LOOP SLING, LARGE 75 75 75 75 75 0034 MLA2000-XL-L1 LAUNDERABLE LOOP SLING, X-LARGE 75 75 75 75 75 The Department of Veterans Affairs (VA) is seeking vendors who can provide Arjo Maxi Move® brand name or equal Lifts: Patient Transfer: Clip Based Standard as listed above or equal commodities which meet all the following salient characteristics (SCs): CLINs 0001 0008 apply to the following SC s. SC # SALIENT CHARACTERISTICS METHOD OF EVALUATION SC 1 Weight capacity that accommodates patients weighing 500 lbs. or greater Literature Review SC 2 Hanger bar maximum lifting height 61 inches or higher Literature Review SC 3 Must have a selection of interchangeable spreader bars for different uses to include loop-based hanger bars Literature Review SC4 Have the ability to access under low beds frames Literature Review SC 5 Have the option for a scale Literature Review SC 6 Battery operation for powered lift Literature Review For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above. The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the OEM and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number. Responses to this Sources Sought Notice shall include the following: Does vendor offer an annual service plan, Yes or No? If Yes: What does the plan cover? Does plan cover software updates only? Does the plan cover parts repair or replacement only? Does the plan cover both software and parts? Vendor are requested to provide documentation that shows information on their service plan. Is the service provided by the OEM or a subcontractor? Full name and address of company DUNS number/ CAGE Code/ SAM UIE Business Size Manufacturer or Distributor If distributor provide full name, business size and address of manufacturer. Country of Origin designation for all products Ability to provide uninterrupted supply of products on a national scale. Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified. Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.

Attachments

Files and links listed on SAM.gov. Files we hold a copy of download from here; the rest open SAM's download, which needs no account. Links open the sites the agency named.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. March 20, 2025

    Sources sought

    Due March 28, 2025 at 4:30 AM EDT. SAM.gov, notice 161fcc0b605b445689c8d4a88ab33452

    1 revision on SAM
    • March 20, 2025: publish, sources sought

Points of contact