{"canonical":"https://sealedbidder.com/opportunities/36c10g25q0044","key":"36C10G25Q0044","url":"https://sealedbidder.com/opportunities/36c10g25q0044","title":"6515--NX EQ Extracorporeal Perfusion Pumps","solicitation_number":"36C10G25Q0044","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-12T20:00:00Z","first_posted":"2025-01-29","last_posted":"2025-01-29","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"334510","psc":"6515","set_aside":null,"place_state":null,"place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":"Product purchase (PSC 6515)","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"87045c32224045f4a08f1330c00bada2","title":"6515--NX EQ Extracorporeal Perfusion Pumps","solicitation_number":"36C10G25Q0044","notice_type":"r","base_type":"r","posted":"2025-01-29","posted_at":"2025-01-29T21:40:42.662Z","due_at":"2025-02-12T20:00:00Z","due_date":"2025-02-12","cancelled":false,"archived":true,"archive_date":"2025-04-13","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/87045c32224045f4a08f1330c00bada2/view","enriched":true,"history":[{"index":3,"title":"6515--NX EQ Extracorporeal Perfusion Pumps","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T21:40:42.662Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"87045c32224045f4a08f1330c00bada2","solicitation_number":"36C10G25Q0044"}]}],"latest_notice_id":"87045c32224045f4a08f1330c00bada2","first_type":"r","notices":[{"award":{"awardee":{}},"dates":{"posted":"2025-01-29","posted_at":"2025-01-29T21:40:42.662Z","created_at":"2025-01-29T21:40:40.497Z","modified_at":"2025-04-14T03:55:49.161Z","response_deadline":{"raw":"2025-02-12T15:00:00-05:00","utc":"2025-02-12T20:00:00Z","date":"2025-02-12","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/87045c32224045f4a08f1330c00bada2/view"},"naics":{"codes":["334510"],"primary":"334510"},"title":"6515--NX EQ Extracorporeal Perfusion Pumps","agency":{"office":{"code":"36C10G","name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"organization_id":"100167093","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-13","archive_type":"auto_custom"},"history":[{"index":3,"title":"6515--NX EQ Extracorporeal Perfusion Pumps","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-29T21:40:42.662Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"87045c32224045f4a08f1330c00bada2","solicitation_number":"36C10G25Q0044"}],"contacts":[{"name":"Daleta Coles","role":"primary","email":"Daleta.Coles@va.gov","phone":"757-722-9961 ext-3115","title":"Contract Specialist"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"87045c32224045f4a08f1330c00bada2","lineage_id":"87045c32224045f4a08f1330c00bada2","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T03:36:47.475430261Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"d15ba8cc780c7098cb9e39361021d022847ac9cc36ae58aaf84ce28bafed4e26","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T03:36:47.475430261Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 10 of 10\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 10\n\n1.0 DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Terumo Extracorporeal Perfusion Pumps or equal product line as a candidate for an Enterprise-wide (otherwise referred to as  national ) single Requirements contract award.\nThe Department of Veterans Affairs  (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. \nThe SAC in conjunction with VHA is seeking a qualified source to provide TerumoÂ® brand name or equal Extracorporeal Perfusion Pumps on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Extracorporeal Perfusion Pumps to VA medical centers and facilities throughout the United States. \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Eletrotherapeutic Apparatus Manufacturing and the associated size standard is 1250 employees. The FAR Provision found at 52.204-7(b)(1) requires that  All interested Offerors must be registered in SAM prior to submitting an offer or proposal.  You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\nThe Terumo Extracorporeal Perfusion Pumps or equal are designed for extracorporeal gas exchange and reinfusion of blood, typically during heart-lung bypass procedures. These pumps (known as extracorporeal perfusion or arterial pumps) consist of either a mechanism that uses centrifugal force (i.e., centrifugal pump) or rollers that cyclically compress the arterial line tubing (i.e., roller pumps). Extracorporeal Perfusion Pumps typically receive blood from the vena cava and deliver it back through the aorta by means of a plastic cannula after processing the blood in an oxygenator/heat exchanger, bypassing the heart and lungs completely. Both a backup arterial pump and connection to an emergency power system are necessary to ensure reliable pump operation.\nThe following Contract Line Items are being considered:\nContract Line Item#\nBrand\nPart Number\nDescription\n0001\nTerumo\n816571\nRoller Pump, 6\" (15.2 cm) Diameter\n0002\nTerumo\n816570\nRoller Pump, 4\" (10.2 cm) Diameter\n0003\nTerumo\n801093\nPole Mount Pump Rest with Bracket\n0004\nTerumo\n816477\nDual Pumps Pole Mount Bracket\n0005\nTerumo\n816483\nDescending Pole Mount Pump Bracket\n0006\nTerumo\n164267\nDrive Motor\n0007\nTerumo\n816571\nControl Unit\n0008\nTerumo\n164268\nManual Drive\n0009\nTerumo\n804372\nPole Mount Centrifugal Display Bracket\n0010\nTerumo\n816620\nFlexible Mounting Arm\n\nThe VA is seeking vendors who can provide Terumo Extracorporeal Perfusion Pumps or equal as listed above which meet all the following salient characteristics (SC): Vendors may offer any product solution or configuration so long as they meet the SC s. Products offered in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may offer any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.\n\nCLIN 0001 applies to SC1\nCLIN 0002 applies to SC2\nCLINs 0001-0002 applies to SC3\nCLINs 0003-0006 applies to SC6\nCLINs 0006-0007 applies to SC5\nCLIN 0008 applies to SC4 \nCLINs 0009-0010 applies to SC7\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nRoller pump with 6-inch head diameter capable of a flow rate of 0-10 L/min\nLiterature Review\nSC 2\nRoller pump with 4-inch head diameter capable of a flow rate of 0-4 L/min\nLiterature Review\nSC 3\nCapable of pulsatile flow\nLiterature Review\nSC 4\nHand crank option for emergency operation\nLiterature Review\nSC 5\nCentrifugal pump capability with adjustable RPMs\nLiterature Review\nSC 6\nBrackets/hardware for mounting roller pumps to a heart-lung bypass cart\nLiterature Review\nSC 7\nBrackets/hardware for mounting centrifugal pump and control unit to a heart-lung bypass cart\nLiterature Review\n\n \nSub-factors\nSafety\nSafety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nFDA Approval\nSingle-Directional Hand Crank for Roller Pumps\nSensors with applicable Visual and Audible Alerts, including Alarm Messages\n\nDesign\nDesign features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nSupports Customization/Modular Configuration for all Major Brands\nSupports Pole Mounting and/or Mounting at the Base of the Heart-Lung Bypass System\nLocalized Control Settings (Directly on Pump) and/or via Heart-Lung Bypass System Control Center\nCapable of Pulsatile Flow\n\nPerformance\nEquipment will be evaluated for its ability to perform its intended function. Areas may include but are not limited to:\nFlow Rates\nWorkflow Integration\n\nQuality/Construction\nAspects of the construction and quality of material of the equipment will be evaluated and may include but not limited to:\nLife Span/Warranty\nEquipment Integration\nMaintenance Requirements\nService Program\nTraining\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above. \nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nFull name and address of company;\nUnique Entity Identifier (UEI) number;\nBusiness Size;\nManufacturer or Distributor;\nIf distributor provide full name, business size and address of manufacturer .\nCountry of Origin designation for all products;\nAbility to provide uninterrupted supply of products on a national scale;\nTechnical Literature that clearly shows product(s) meet the identified SCs (if submitting an  or-equal  item);\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","text":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 10 of 10\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 10\n\n1.0 DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Terumo Extracorporeal Perfusion Pumps or equal product line as a candidate for an Enterprise-wide (otherwise referred to as national ) single Requirements contract award.\nThe Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.\nThe SAC in conjunction with VHA is seeking a qualified source to provide TerumoÂ® brand name or equal Extracorporeal Perfusion Pumps on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Extracorporeal Perfusion Pumps to VA medical centers and facilities throughout the United States.\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Eletrotherapeutic Apparatus Manufacturing and the associated size standard is 1250 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\nThe Terumo Extracorporeal Perfusion Pumps or equal are designed for extracorporeal gas exchange and reinfusion of blood, typically during heart-lung bypass procedures. These pumps (known as extracorporeal perfusion or arterial pumps) consist of either a mechanism that uses centrifugal force (i.e., centrifugal pump) or rollers that cyclically compress the arterial line tubing (i.e., roller pumps). Extracorporeal Perfusion Pumps typically receive blood from the vena cava and deliver it back through the aorta by means of a plastic cannula after processing the blood in an oxygenator/heat exchanger, bypassing the heart and lungs completely. Both a backup arterial pump and connection to an emergency power system are necessary to ensure reliable pump operation.\nThe following Contract Line Items are being considered:\nContract Line Item#\nBrand\nPart Number\nDescription\n0001\nTerumo\n816571\nRoller Pump, 6\" (15.2 cm) Diameter\n0002\nTerumo\n816570\nRoller Pump, 4\" (10.2 cm) Diameter\n0003\nTerumo\n801093\nPole Mount Pump Rest with Bracket\n0004\nTerumo\n816477\nDual Pumps Pole Mount Bracket\n0005\nTerumo\n816483\nDescending Pole Mount Pump Bracket\n0006\nTerumo\n164267\nDrive Motor\n0007\nTerumo\n816571\nControl Unit\n0008\nTerumo\n164268\nManual Drive\n0009\nTerumo\n804372\nPole Mount Centrifugal Display Bracket\n0010\nTerumo\n816620\nFlexible Mounting Arm\n\nThe VA is seeking vendors who can provide Terumo Extracorporeal Perfusion Pumps or equal as listed above which meet all the following salient characteristics (SC): Vendors may offer any product solution or configuration so long as they meet the SC s. Products offered in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may offer any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.\n\nCLIN 0001 applies to SC1\nCLIN 0002 applies to SC2\nCLINs 0001-0002 applies to SC3\nCLINs 0003-0006 applies to SC6\nCLINs 0006-0007 applies to SC5\nCLIN 0008 applies to SC4\nCLINs 0009-0010 applies to SC7\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nRoller pump with 6-inch head diameter capable of a flow rate of 0-10 L/min\nLiterature Review\nSC 2\nRoller pump with 4-inch head diameter capable of a flow rate of 0-4 L/min\nLiterature Review\nSC 3\nCapable of pulsatile flow\nLiterature Review\nSC 4\nHand crank option for emergency operation\nLiterature Review\nSC 5\nCentrifugal pump capability with adjustable RPMs\nLiterature Review\nSC 6\nBrackets/hardware for mounting roller pumps to a heart-lung bypass cart\nLiterature Review\nSC 7\nBrackets/hardware for mounting centrifugal pump and control unit to a heart-lung bypass cart\nLiterature Review\n\nSub-factors\nSafety\nSafety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nFDA Approval\nSingle-Directional Hand Crank for Roller Pumps\nSensors with applicable Visual and Audible Alerts, including Alarm Messages\n\nDesign\nDesign features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nSupports Customization/Modular Configuration for all Major Brands\nSupports Pole Mounting and/or Mounting at the Base of the Heart-Lung Bypass System\nLocalized Control Settings (Directly on Pump) and/or via Heart-Lung Bypass System Control Center\nCapable of Pulsatile Flow\n\nPerformance\nEquipment will be evaluated for its ability to perform its intended function. Areas may include but are not limited to:\nFlow Rates\nWorkflow Integration\n\nQuality/Construction\nAspects of the construction and quality of material of the equipment will be evaluated and may include but not limited to:\nLife Span/Warranty\nEquipment Integration\nMaintenance Requirements\nService Program\nTraining\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nFull name and address of company;\nUnique Entity Identifier (UEI) number;\nBusiness Size;\nManufacturer or Distributor;\nIf distributor provide full name, business size and address of manufacturer .\nCountry of Origin designation for all products;\nAbility to provide uninterrupted supply of products on a national scale;\nTechnical Literature that clearly shows product(s) meet the identified SCs (if submitting an or-equal item);\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"36C10G25Q0044","place_of_performance":{"street":"Enterprise-wide","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6515"}],"due_at":"2025-02-12T20:00:00Z","due_date":"2025-02-12","closes_at":"2025-02-12T20:00:00Z","awardable":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"updated_at":"2026-11-24T03:44:56.691144Z","principal_notice_id":"87045c32224045f4a08f1330c00bada2","description":{"text":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 10 of 10\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 10\n\n1.0 DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Terumo Extracorporeal Perfusion Pumps or equal product line as a candidate for an Enterprise-wide (otherwise referred to as national ) single Requirements contract award.\nThe Department of Veterans Affairs (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.\nThe SAC in conjunction with VHA is seeking a qualified source to provide TerumoÂ® brand name or equal Extracorporeal Perfusion Pumps on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Extracorporeal Perfusion Pumps to VA medical centers and facilities throughout the United States.\nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Eletrotherapeutic Apparatus Manufacturing and the associated size standard is 1250 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM prior to submitting an offer or proposal. You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\nThe Terumo Extracorporeal Perfusion Pumps or equal are designed for extracorporeal gas exchange and reinfusion of blood, typically during heart-lung bypass procedures. These pumps (known as extracorporeal perfusion or arterial pumps) consist of either a mechanism that uses centrifugal force (i.e., centrifugal pump) or rollers that cyclically compress the arterial line tubing (i.e., roller pumps). Extracorporeal Perfusion Pumps typically receive blood from the vena cava and deliver it back through the aorta by means of a plastic cannula after processing the blood in an oxygenator/heat exchanger, bypassing the heart and lungs completely. Both a backup arterial pump and connection to an emergency power system are necessary to ensure reliable pump operation.\nThe following Contract Line Items are being considered:\nContract Line Item#\nBrand\nPart Number\nDescription\n0001\nTerumo\n816571\nRoller Pump, 6\" (15.2 cm) Diameter\n0002\nTerumo\n816570\nRoller Pump, 4\" (10.2 cm) Diameter\n0003\nTerumo\n801093\nPole Mount Pump Rest with Bracket\n0004\nTerumo\n816477\nDual Pumps Pole Mount Bracket\n0005\nTerumo\n816483\nDescending Pole Mount Pump Bracket\n0006\nTerumo\n164267\nDrive Motor\n0007\nTerumo\n816571\nControl Unit\n0008\nTerumo\n164268\nManual Drive\n0009\nTerumo\n804372\nPole Mount Centrifugal Display Bracket\n0010\nTerumo\n816620\nFlexible Mounting Arm\n\nThe VA is seeking vendors who can provide Terumo Extracorporeal Perfusion Pumps or equal as listed above which meet all the following salient characteristics (SC): Vendors may offer any product solution or configuration so long as they meet the SC s. Products offered in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may offer any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.\n\nCLIN 0001 applies to SC1\nCLIN 0002 applies to SC2\nCLINs 0001-0002 applies to SC3\nCLINs 0003-0006 applies to SC6\nCLINs 0006-0007 applies to SC5\nCLIN 0008 applies to SC4\nCLINs 0009-0010 applies to SC7\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nRoller pump with 6-inch head diameter capable of a flow rate of 0-10 L/min\nLiterature Review\nSC 2\nRoller pump with 4-inch head diameter capable of a flow rate of 0-4 L/min\nLiterature Review\nSC 3\nCapable of pulsatile flow\nLiterature Review\nSC 4\nHand crank option for emergency operation\nLiterature Review\nSC 5\nCentrifugal pump capability with adjustable RPMs\nLiterature Review\nSC 6\nBrackets/hardware for mounting roller pumps to a heart-lung bypass cart\nLiterature Review\nSC 7\nBrackets/hardware for mounting centrifugal pump and control unit to a heart-lung bypass cart\nLiterature Review\n\nSub-factors\nSafety\nSafety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nFDA Approval\nSingle-Directional Hand Crank for Roller Pumps\nSensors with applicable Visual and Audible Alerts, including Alarm Messages\n\nDesign\nDesign features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nSupports Customization/Modular Configuration for all Major Brands\nSupports Pole Mounting and/or Mounting at the Base of the Heart-Lung Bypass System\nLocalized Control Settings (Directly on Pump) and/or via Heart-Lung Bypass System Control Center\nCapable of Pulsatile Flow\n\nPerformance\nEquipment will be evaluated for its ability to perform its intended function. Areas may include but are not limited to:\nFlow Rates\nWorkflow Integration\n\nQuality/Construction\nAspects of the construction and quality of material of the equipment will be evaluated and may include but not limited to:\nLife Span/Warranty\nEquipment Integration\nMaintenance Requirements\nService Program\nTraining\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above.\nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nFull name and address of company;\nUnique Entity Identifier (UEI) number;\nBusiness Size;\nManufacturer or Distributor;\nIf distributor provide full name, business size and address of manufacturer .\nCountry of Origin designation for all products;\nAbility to provide uninterrupted supply of products on a national scale;\nTechnical Literature that clearly shows product(s) meet the identified SCs (if submitting an or-equal item);\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","html":"Sources Sought Notice\n\nSources Sought Notice\n\nPage 10 of 10\nSources Sought Notice\n*= Required Field\nSources Sought Notice\n\nPage 1 of 10\n\n1.0 DESCRIPTION\nThe Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Terumo Extracorporeal Perfusion Pumps or equal product line as a candidate for an Enterprise-wide (otherwise referred to as  national ) single Requirements contract award.\nThe Department of Veterans Affairs  (VA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources. \nThe SAC in conjunction with VHA is seeking a qualified source to provide TerumoÂ® brand name or equal Extracorporeal Perfusion Pumps on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Extracorporeal Perfusion Pumps to VA medical centers and facilities throughout the United States. \nThe anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether or not to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.\nThe associated North American Industrial Classification System (NAICS) code for this procurement is 334510 Electromedical and Eletrotherapeutic Apparatus Manufacturing and the associated size standard is 1250 employees. The FAR Provision found at 52.204-7(b)(1) requires that  All interested Offerors must be registered in SAM prior to submitting an offer or proposal.  You may access the SAM website at Home | SAM.gov. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the Small Business Administration (SBA) database at Veteran Small Business Certification (VetCert) database at: Veteran Small Business Certification (sba.gov) at the time of proposal submission.\nThis notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.\n2.0 SCOPE\nThe Terumo Extracorporeal Perfusion Pumps or equal are designed for extracorporeal gas exchange and reinfusion of blood, typically during heart-lung bypass procedures. These pumps (known as extracorporeal perfusion or arterial pumps) consist of either a mechanism that uses centrifugal force (i.e., centrifugal pump) or rollers that cyclically compress the arterial line tubing (i.e., roller pumps). Extracorporeal Perfusion Pumps typically receive blood from the vena cava and deliver it back through the aorta by means of a plastic cannula after processing the blood in an oxygenator/heat exchanger, bypassing the heart and lungs completely. Both a backup arterial pump and connection to an emergency power system are necessary to ensure reliable pump operation.\nThe following Contract Line Items are being considered:\nContract Line Item#\nBrand\nPart Number\nDescription\n0001\nTerumo\n816571\nRoller Pump, 6\" (15.2 cm) Diameter\n0002\nTerumo\n816570\nRoller Pump, 4\" (10.2 cm) Diameter\n0003\nTerumo\n801093\nPole Mount Pump Rest with Bracket\n0004\nTerumo\n816477\nDual Pumps Pole Mount Bracket\n0005\nTerumo\n816483\nDescending Pole Mount Pump Bracket\n0006\nTerumo\n164267\nDrive Motor\n0007\nTerumo\n816571\nControl Unit\n0008\nTerumo\n164268\nManual Drive\n0009\nTerumo\n804372\nPole Mount Centrifugal Display Bracket\n0010\nTerumo\n816620\nFlexible Mounting Arm\n\nThe VA is seeking vendors who can provide Terumo Extracorporeal Perfusion Pumps or equal as listed above which meet all the following salient characteristics (SC): Vendors may offer any product solution or configuration so long as they meet the SC s. Products offered in the technical volume must be captured on the Vendor s pricing volume (Attachment A, Price Cost Schedule) of the solicitation. Vendors may offer any additional ancillary products which they deem to be essential to the functionality of the proposed solution; these items must be captured in the Vendor s pricing volume with a quantity of zero.\n\nCLIN 0001 applies to SC1\nCLIN 0002 applies to SC2\nCLINs 0001-0002 applies to SC3\nCLINs 0003-0006 applies to SC6\nCLINs 0006-0007 applies to SC5\nCLIN 0008 applies to SC4 \nCLINs 0009-0010 applies to SC7\n\nSC #\nSALIENT CHARACTERISTICS\nMETHOD OF EVALUATION\nSC 1\nRoller pump with 6-inch head diameter capable of a flow rate of 0-10 L/min\nLiterature Review\nSC 2\nRoller pump with 4-inch head diameter capable of a flow rate of 0-4 L/min\nLiterature Review\nSC 3\nCapable of pulsatile flow\nLiterature Review\nSC 4\nHand crank option for emergency operation\nLiterature Review\nSC 5\nCentrifugal pump capability with adjustable RPMs\nLiterature Review\nSC 6\nBrackets/hardware for mounting roller pumps to a heart-lung bypass cart\nLiterature Review\nSC 7\nBrackets/hardware for mounting centrifugal pump and control unit to a heart-lung bypass cart\nLiterature Review\n\n \nSub-factors\nSafety\nSafety features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nFDA Approval\nSingle-Directional Hand Crank for Roller Pumps\nSensors with applicable Visual and Audible Alerts, including Alarm Messages\n\nDesign\nDesign features and functions of the offered equipment will be evaluated. Areas may include but are not limited to the following:\nSupports Customization/Modular Configuration for all Major Brands\nSupports Pole Mounting and/or Mounting at the Base of the Heart-Lung Bypass System\nLocalized Control Settings (Directly on Pump) and/or via Heart-Lung Bypass System Control Center\nCapable of Pulsatile Flow\n\nPerformance\nEquipment will be evaluated for its ability to perform its intended function. Areas may include but are not limited to:\nFlow Rates\nWorkflow Integration\n\nQuality/Construction\nAspects of the construction and quality of material of the equipment will be evaluated and may include but not limited to:\nLife Span/Warranty\nEquipment Integration\nMaintenance Requirements\nService Program\nTraining\n\nFor each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the SCs specified above. \nThe Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the SCs. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.\nResponses to this Sources Sought Notice shall include the following:\nFull name and address of company;\nUnique Entity Identifier (UEI) number;\nBusiness Size;\nManufacturer or Distributor;\nIf distributor provide full name, business size and address of manufacturer .\nCountry of Origin designation for all products;\nAbility to provide uninterrupted supply of products on a national scale;\nTechnical Literature that clearly shows product(s) meet the identified SCs (if submitting an  or-equal  item);\nAny additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.\n\nAlthough not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.","origin":"detail"},"contacts":[{"name":"Daleta Coles","role":"primary","email":"Daleta.Coles@va.gov","phone":"757-722-9961 ext-3115","title":"Contract Specialist"}],"place_of_performance":{"street":"Enterprise-wide","country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"22408","city":"FREDERICKSBURG","state":"VA","country":"USA"},"naics_codes":["334510"],"award":{"awardee":{}},"attachments":[{"resource_id":"e7980ba7a74f48999f69b03ccc1d4392","name":"36C10G25Q0044.docx","kind":"file","mime_type":".docx","size_bytes":26490,"posted_at":"2025-01-29T21:40:42.662Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/e7980ba7a74f48999f69b03ccc1d4392/download","mirrored":false},{"resource_id":"dbb8a5331d2049c980f649278363636b","name":"To learn more about SAC and its mission, please click here","kind":"link","mime_type":null,"size_bytes":null,"posted_at":"2025-01-29T21:40:42.662Z","export_controlled":false,"sha256":null,"url":"https://www.va.gov/opal/sac/index.asp","mirrored":false}],"awards":[],"related":[{"key":"36C10G27R0002","latest_notice_id":"f16ea5b6f90d4b3e903edd9b27a5c3aa","title":"6515--Patient Lifts and Slings for In Home Use","solicitation_number":"36C10G27R0002","notice_type":"o","first_type":"o","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":4,"due_at":"2026-12-15T17:00:00Z","due_date":"2026-12-15","closes_at":"2026-12-15T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10G","office_name":"STRATEGIC ACQUISITION CENTER FREDERICKSBURG (36C10G)","naics":"339113","psc":"6515","set_aside":"SBP","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"}],"similar_open":[{"key":"75N98027Q00094","latest_notice_id":"fe80b99f89894110b18ddb4d826a2131","title":"NCSS - Sentec tCOM+ Transcutaneous CO2 Monitor Acq","solicitation_number":"75N98027Q00094","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-17","notices":1,"due_at":"2026-11-27T16:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N980","office_name":"NATIONAL INSTITUTES OF HEALTH OLAO","naics":"334510","psc":"6515","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"36C10X27R0005","latest_notice_id":"e932ae7c1a2641ef910a7fa47204c74e","title":"6515--NX EQ Ultrasonic Aspirator System: Tissue Ablation (VA-27-00010132)","solicitation_number":"36C10X27R0005","notice_type":"k","first_type":"k","first_posted":"2026-11-09","last_posted":"2026-11-18","notices":3,"due_at":"2026-12-01T15:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"36C10X27Q0033","latest_notice_id":"2bf06c09e95d4059b2bdae0c88e09c15","title":"6515--Copy of NX EQ Thulium Fiber Laser (VA-27-00003102)","solicitation_number":"36C10X27Q0033","notice_type":"k","first_type":"k","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":1,"due_at":"2026-12-11T04:59:00Z","due_date":"2026-12-10","closes_at":"2026-12-11T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10X","office_name":"SAC FREDERICK (36C10X)","naics":"334510","psc":"6515","set_aside":"SDVOSBC","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6515)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":11,"indexable":false}