{"canonical":"https://sealedbidder.com/opportunities/33330226rf0010002","key":"33330226RF0010002","url":"https://sealedbidder.com/opportunities/33330226rf0010002","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-03T19:00:00Z","first_posted":"2026-02-20","last_posted":"2026-09-29","department":"SMITHSONIAN INSTITUTION","subagency":"SMITHSONIAN INSTITUTION","office":"SMITHSONIAN INSTITUTION","naics":"236220","psc":"Y1JA","set_aside":null,"place_state":"DC","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"11001","place_county_name":"District of Columbia","place_city":"1150000","place_city_name":"Washington","winner":"GRUNLEY CONSTRUCTION CO., INC.","award_amount":"12034000.00","publications":[{"notice_id":"71e593271c52429e9ed018da49afadec","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"p","base_type":"p","posted":"2026-02-20","posted_at":"2026-02-20T14:50:54.559Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-03-20","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/71e593271c52429e9ed018da49afadec/view","enriched":true,"history":[{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"71e593271c52429e9ed018da49afadec","solicitation_number":"33330226RF0010002"}]},{"notice_id":"85e7d813bb344bf59fec90ac56e2dbcc","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"p","base_type":"p","posted":"2026-02-20","posted_at":"2026-02-20T14:50:54.559Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-03-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/85e7d813bb344bf59fec90ac56e2dbcc/view","enriched":true,"history":[{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"71e593271c52429e9ed018da49afadec","solicitation_number":"33330226RF0010002"}]},{"notice_id":"6c747abf197b44d6a77f634681c5a389","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"o","base_type":"p","posted":"2026-03-12","posted_at":"2026-03-12T12:01:16.547Z","due_at":"2026-05-12T19:00:00Z","due_date":"2026-05-12","cancelled":false,"archived":true,"archive_date":"2026-05-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6c747abf197b44d6a77f634681c5a389/view","enriched":true,"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}]},{"notice_id":"b07dcb24f13242788352a09b33825667","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"o","base_type":"o","posted":"2026-04-02","posted_at":"2026-04-02T19:27:12.370Z","due_at":"2026-05-12T19:00:00Z","due_date":"2026-05-12","cancelled":false,"archived":true,"archive_date":"2026-05-27","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b07dcb24f13242788352a09b33825667/view","enriched":true,"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}]},{"notice_id":"550b7638a6d04a43971f2541e7113f5d","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"o","base_type":"o","posted":"2026-04-21","posted_at":"2026-04-21T16:57:11.237Z","due_at":"2026-05-20T19:00:00Z","due_date":"2026-05-20","cancelled":false,"archived":true,"archive_date":"2026-06-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/550b7638a6d04a43971f2541e7113f5d/view","enriched":true,"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}]},{"notice_id":"ce4c4b6bdfb84efa9905cc814d45dcff","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"o","base_type":"o","posted":"2026-04-28","posted_at":"2026-04-28T17:52:27.816Z","due_at":"2026-05-20T19:00:00Z","due_date":"2026-05-20","cancelled":false,"archived":true,"archive_date":"2026-06-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ce4c4b6bdfb84efa9905cc814d45dcff/view","enriched":true,"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}]},{"notice_id":"71e34bf1f66243aca63cc863030a0288","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"o","base_type":"o","posted":"2026-05-07","posted_at":"2026-05-07T19:36:50.548Z","due_at":"2026-05-20T19:00:00Z","due_date":"2026-05-20","cancelled":false,"archived":true,"archive_date":"2026-06-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/71e34bf1f66243aca63cc863030a0288/view","enriched":true,"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}]},{"notice_id":"19b29af3d3bf4e5cb754d96ab7e7837e","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226RF0010002","notice_type":"o","base_type":"o","posted":"2026-05-14","posted_at":"2026-05-14T19:43:00.853Z","due_at":"2026-06-03T19:00:00Z","due_date":"2026-06-03","cancelled":false,"archived":true,"archive_date":"2026-06-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/19b29af3d3bf4e5cb754d96ab7e7837e/view","enriched":true,"history":[{"index":9,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T13:10:45.742Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"1278ddd2547644cdaf945d8e8496c718","solicitation_number":"33330226CF0010408","related_opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e"},{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}]},{"notice_id":"1278ddd2547644cdaf945d8e8496c718","title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","solicitation_number":"33330226CF0010408","notice_type":"a","base_type":"o","posted":"2026-09-29","posted_at":"2026-09-29T13:10:45.742Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-10-09","removed_at":null,"award_number":"33330226CF0010408","awardee_name":"GRUNLEY CONSTRUCTION CO., INC.","amount":"12034000.00","link_sam":"https://sam.gov/workspace/contract/opp/1278ddd2547644cdaf945d8e8496c718/view","enriched":true,"history":[{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T13:10:45.742Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"1278ddd2547644cdaf945d8e8496c718","solicitation_number":"33330226CF0010408","related_opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"}]}],"latest_notice_id":"1278ddd2547644cdaf945d8e8496c718","first_type":"p","notices":[{"dates":{"posted":"2026-02-20","posted_at":"2026-02-20T14:50:54.559Z","created_at":"2026-02-20T14:46:09.744Z","modified_at":"2026-03-12T11:37:29.510Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/71e593271c52429e9ed018da49afadec/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_id":"100188266","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-20","archive_type":"auto_custom"},"history":[{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"71e593271c52429e9ed018da49afadec","solicitation_number":"33330226RF0010002"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"71e593271c52429e9ed018da49afadec","lineage_id":"71e593271c52429e9ed018da49afadec","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-12T10:14:44.369012206Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"4fd43791a08026fc9c70fcd8c4bff9416f085208beddc79d874cc84b46310d4a","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-12T10:14:44.369012206Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p><strong>PRE-SOLICITATION NOTICE</strong></p>\n\n<p>UPGRADE SANITARY AND STORM SYSTEMS PROJECT AT THE SMITHSONIAN NATIONAL MUSEUM OF NATURAL HISTORY, LOCATED IN WASHINGTON, DC</p>\n\n<p>The Smithsonian Institution (SI) is seeking offers to Upgrade Sanitary and Storm Systems project at the Smithsonian National Museum of Natural History, located in Washington DC.</p>\n\n<p>The North American Industry Classification System (NAICS) code for this action is 236220 and the small business size standard is $45M.</p>\n\n<p><strong>PROJECT INFORMATION:</strong> The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum&rsquo;s collections, exhibits, and research operations, and preserve its historic architecture features.</p>\n\n<p>The major elements of work include, but are not limited to, the following:</p>\n\n<ul>\n\t<li>Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.</li>\n\t<li>Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.</li>\n\t<li>Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.</li>\n\t<li>Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.</li>\n\t<li>Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.</li>\n\t<li>Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required. Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.</li>\n\t<li>Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.</li>\n\t<li>Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.</li>\n</ul>\n\n<p>All work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.</p>\n\n<p>The Period of Performance for the Base and Options, if exercised, is 730 Calendar Days from the date of Notice to Proceed.</p>\n\n<p>Total Estimated cost range is between is over $10 million. &nbsp;</p>\n\n<p><strong>LOCATION:</strong></p>\n\n<p>Project will be located at 10th Street &amp; Constitution Avenue, NW, Washington, DC 20560.</p>\n\n<p><strong>SET ASIDE</strong>: Not Applicable</p>\n\n<p><strong>THIS IS NOT A REQUEST FOR PROPOSAL</strong>. The full solicitation, request for proposals, will be released on or about early March 2026; however, there is no guarantee or implication of a guarantee this this project will be solicited. Responses will be due within (45) days of release. Electronic copies will be uploaded to SAM.gov site. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response.</p>\n\n<p>The Smithsonian Institution will accept proposals from all qualified offerors. The Smithsonian Institution&rsquo;s evaluation panel will be the sole entity to determine as to whether an offeror is capable of meeting the requirements to carry out contract performance.</p>\n\n<p>No attachments or links have been added to this opportunity.</p>","text":"PRE-SOLICITATION NOTICE\n\nUPGRADE SANITARY AND STORM SYSTEMS PROJECT AT THE SMITHSONIAN NATIONAL MUSEUM OF NATURAL HISTORY, LOCATED IN WASHINGTON, DC\n\nThe Smithsonian Institution (SI) is seeking offers to Upgrade Sanitary and Storm Systems project at the Smithsonian National Museum of Natural History, located in Washington DC.\n\nThe North American Industry Classification System (NAICS) code for this action is 236220 and the small business size standard is $45M.\n\nPROJECT INFORMATION: The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum’s collections, exhibits, and research operations, and preserve its historic architecture features.\n\nThe major elements of work include, but are not limited to, the following:\n\n• Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.\n\n• Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.\n\n• Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.\n\n• Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.\n\n• Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.\n\n• Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required. Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.\n\n• Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.\n\n• Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.\n\nAll work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.\n\nThe Period of Performance for the Base and Options, if exercised, is 730 Calendar Days from the date of Notice to Proceed.\n\nTotal Estimated cost range is between is over $10 million.\n\nLOCATION:\n\nProject will be located at 10th Street & Constitution Avenue, NW, Washington, DC 20560.\n\nSET ASIDE: Not Applicable\n\nTHIS IS NOT A REQUEST FOR PROPOSAL. The full solicitation, request for proposals, will be released on or about early March 2026; however, there is no guarantee or implication of a guarantee this this project will be solicited. Responses will be due within (45) days of release. Electronic copies will be uploaded to SAM.gov site. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response.\n\nThe Smithsonian Institution will accept proposals from all qualified offerors. The Smithsonian Institution’s evaluation panel will be the sole entity to determine as to whether an offeror is capable of meeting the requirements to carry out contract performance.\n\nNo attachments or links have been added to this opportunity.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"33330226RF0010002","place_of_performance":{"zip":"20560","state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1JA"},{"dates":{"posted":"2026-02-20","posted_at":"2026-02-20T14:50:54.559Z","created_at":"2026-03-12T11:37:29.510Z","modified_at":"2026-03-12T11:37:29.510Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/85e7d813bb344bf59fec90ac56e2dbcc/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_id":"100188266","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-12","archive_type":"manual"},"history":[{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"71e593271c52429e9ed018da49afadec","solicitation_number":"33330226RF0010002"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"85e7d813bb344bf59fec90ac56e2dbcc","lineage_id":"71e593271c52429e9ed018da49afadec","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-12T10:17:48.888410269Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"e54b26a13b4c25c412abeacb989db9516ab0f4968729f8098c9a8c72e14601f2","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-12T10:17:48.888410269Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p><strong>PRE-SOLICITATION NOTICE</strong></p>\n\n<p>UPGRADE SANITARY AND STORM SYSTEMS PROJECT AT THE SMITHSONIAN NATIONAL MUSEUM OF NATURAL HISTORY, LOCATED IN WASHINGTON, DC</p>\n\n<p>The Smithsonian Institution (SI) is seeking offers to Upgrade Sanitary and Storm Systems project at the Smithsonian National Museum of Natural History, located in Washington DC.</p>\n\n<p>The North American Industry Classification System (NAICS) code for this action is 236220 and the small business size standard is $45M.</p>\n\n<p><strong>PROJECT INFORMATION:</strong> The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum&rsquo;s collections, exhibits, and research operations, and preserve its historic architecture features.</p>\n\n<p>The major elements of work include, but are not limited to, the following:</p>\n\n<ul>\n\t<li>Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.</li>\n\t<li>Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.</li>\n\t<li>Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.</li>\n\t<li>Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.</li>\n\t<li>Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.</li>\n\t<li>Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required. Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.</li>\n\t<li>Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.</li>\n\t<li>Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.</li>\n</ul>\n\n<p>All work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.</p>\n\n<p>The Period of Performance for the Base and Options, if exercised, is 730 Calendar Days from the date of Notice to Proceed.</p>\n\n<p>Total Estimated cost range is between is over $10 million. &nbsp;</p>\n\n<p><strong>LOCATION:</strong></p>\n\n<p>Project will be located at 10th Street &amp; Constitution Avenue, NW, Washington, DC 20560.</p>\n\n<p><strong>SET ASIDE</strong>: Not Applicable</p>\n\n<p><strong>THIS IS NOT A REQUEST FOR PROPOSAL</strong>. The full solicitation, request for proposals, will be released on or about early March 2026; however, there is no guarantee or implication of a guarantee this this project will be solicited. Responses will be due within (45) days of release. Electronic copies will be uploaded to SAM.gov site. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response.</p>\n\n<p>The Smithsonian Institution will accept proposals from all qualified offerors. The Smithsonian Institution&rsquo;s evaluation panel will be the sole entity to determine as to whether an offeror is capable of meeting the requirements to carry out contract performance.</p>\n\n<p>No attachments or links have been added to this opportunity.</p>","text":"PRE-SOLICITATION NOTICE\n\nUPGRADE SANITARY AND STORM SYSTEMS PROJECT AT THE SMITHSONIAN NATIONAL MUSEUM OF NATURAL HISTORY, LOCATED IN WASHINGTON, DC\n\nThe Smithsonian Institution (SI) is seeking offers to Upgrade Sanitary and Storm Systems project at the Smithsonian National Museum of Natural History, located in Washington DC.\n\nThe North American Industry Classification System (NAICS) code for this action is 236220 and the small business size standard is $45M.\n\nPROJECT INFORMATION: The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum’s collections, exhibits, and research operations, and preserve its historic architecture features.\n\nThe major elements of work include, but are not limited to, the following:\n\n• Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.\n\n• Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.\n\n• Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.\n\n• Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.\n\n• Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.\n\n• Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required. Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.\n\n• Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.\n\n• Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.\n\nAll work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.\n\nThe Period of Performance for the Base and Options, if exercised, is 730 Calendar Days from the date of Notice to Proceed.\n\nTotal Estimated cost range is between is over $10 million.\n\nLOCATION:\n\nProject will be located at 10th Street & Constitution Avenue, NW, Washington, DC 20560.\n\nSET ASIDE: Not Applicable\n\nTHIS IS NOT A REQUEST FOR PROPOSAL. The full solicitation, request for proposals, will be released on or about early March 2026; however, there is no guarantee or implication of a guarantee this this project will be solicited. Responses will be due within (45) days of release. Electronic copies will be uploaded to SAM.gov site. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response.\n\nThe Smithsonian Institution will accept proposals from all qualified offerors. The Smithsonian Institution’s evaluation panel will be the sole entity to determine as to whether an offeror is capable of meeting the requirements to carry out contract performance.\n\nNo attachments or links have been added to this opportunity.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"33330226RF0010002","place_of_performance":{"zip":"20560","state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1JA"},{"dates":{"posted":"2026-03-12","posted_at":"2026-03-12T12:01:16.547Z","created_at":"2026-03-12T11:38:13.362Z","modified_at":"2026-06-19T03:55:46.378Z","response_deadline":{"raw":"2026-05-12T15:00:00-04:00","utc":"2026-05-12T19:00:00Z","date":"2026-05-12","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6c747abf197b44d6a77f634681c5a389/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_id":"100188266","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-27","archive_type":"auto15"},"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"6c747abf197b44d6a77f634681c5a389","lineage_id":"6c747abf197b44d6a77f634681c5a389","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-11T04:41:11.624812198Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"0e278012b42567f60bb06636aa7b959590b67a5ea1d3fd88a9556c693d30bf70","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-11T04:41:11.624812198Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution&#39;s National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.</p>\n\n<p>All of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.</p>\n\n<p>The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum&rsquo;s collections, exhibits, and research operations, and preserve its historic architecture features.</p>\n\n<p>The major elements of work include, but are not limited to, the following:</p>\n\n<ul>\n\t<li>Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.</li>\n\t<li>Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.</li>\n\t<li>Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.</li>\n\t<li>Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.</li>\n\t<li>Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.</li>\n\t<li>Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.</li>\n\t<li>Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.</li>\n\t<li>Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.</li>\n\t<li>Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.</li>\n</ul>\n\n<p>All work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.</p>\n\n<p></p>\n\n<p><strong>PRE-BID TOUR OF THE SITE</strong></p>\n\n<p>The Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.</p>\n\n<p><strong>REQUEST FOR CLARIFICATIONS</strong></p>\n\n<p>It is requested that all questions be sent in no later than April 14, 2026.</p>\n\n<p></p>\n\n<p><strong>THE PROPOSAL DUE DATE IS </strong><strong>TUESDAY, MAY 12, 2026, at 3:00 PM </strong><strong>EASTERN STANDARD TIME (EST).</strong></p>\n\n<p></p>\n\n<p>The subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).</p>\n\n<p>Davis Bacon Building Wage Determination DC20260002 shall apply.</p>\n\n<p>The Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to&nbsp;&nbsp; Proceed.</p>","text":"The Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution's National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.\n\nAll of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.\n\nThe scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum’s collections, exhibits, and research operations, and preserve its historic architecture features.\n\nThe major elements of work include, but are not limited to, the following:\n\n• Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.\n\n• Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.\n\n• Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.\n\n• Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.\n\n• Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.\n\n• Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.\n\n• Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.\n\n• Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.\n\n• Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.\n\nAll work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.\n\nPRE-BID TOUR OF THE SITE\n\nThe Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.\n\nREQUEST FOR CLARIFICATIONS\n\nIt is requested that all questions be sent in no later than April 14, 2026.\n\nTHE PROPOSAL DUE DATE IS TUESDAY, MAY 12, 2026, at 3:00 PM EASTERN STANDARD TIME (EST).\n\nThe subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).\n\nDavis Bacon Building Wage Determination DC20260002 shall apply.\n\nThe Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to Proceed.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"33330226RF0010002","place_of_performance":{"zip":"20560","state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1JA"},{"dates":{"posted":"2026-04-02","posted_at":"2026-04-02T19:27:12.370Z","created_at":"2026-04-02T19:23:31.797Z","modified_at":"2026-06-19T03:55:46.378Z","response_deadline":{"raw":"2026-05-12T15:00:00-04:00","utc":"2026-05-12T19:00:00Z","date":"2026-05-12","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b07dcb24f13242788352a09b33825667/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_id":"100188266","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-27","archive_type":"auto15"},"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"b07dcb24f13242788352a09b33825667","lineage_id":"6c747abf197b44d6a77f634681c5a389","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-08T23:22:03.592879142Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"fb901b1d2f2969ad9e0f59f7707b1fd0166ac217734e98c008856086133549ed","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-08T23:22:03.592879142Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p><strong>Amendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:</strong></p>\n\n<p><strong>03/27 Site Visit Sign-in Sheet</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p>The Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution&#39;s National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.</p>\n\n<p>All of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.</p>\n\n<p>The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum&rsquo;s collections, exhibits, and research operations, and preserve its historic architecture features.</p>\n\n<p>The major elements of work include, but are not limited to, the following:</p>\n\n<ul>\n\t<li>Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.</li>\n\t<li>Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.</li>\n\t<li>Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.</li>\n\t<li>Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.</li>\n\t<li>Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.</li>\n\t<li>Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.</li>\n\t<li>Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.</li>\n\t<li>Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.</li>\n\t<li>Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.</li>\n</ul>\n\n<p>All work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.</p>\n\n<p></p>\n\n<p><strong>PRE-BID TOUR OF THE SITE</strong></p>\n\n<p>The Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.</p>\n\n<p><strong>REQUEST FOR CLARIFICATIONS</strong></p>\n\n<p>It is requested that all questions be sent in no later than April 14, 2026.</p>\n\n<p></p>\n\n<p><strong>THE PROPOSAL DUE DATE IS </strong><strong>TUESDAY, MAY 12, 2026, at 3:00 PM </strong><strong>EASTERN STANDARD TIME (EST).</strong></p>\n\n<p></p>\n\n<p>The subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).</p>\n\n<p>Davis Bacon Building Wage Determination DC20260002 shall apply.</p>\n\n<p>The Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to&nbsp;&nbsp; Proceed.</p>","text":"Amendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:\n\n03/27 Site Visit Sign-in Sheet\n\n---------------------------------------------------------------------------------------------------------\n\nThe Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution's National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.\n\nAll of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.\n\nThe scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum’s collections, exhibits, and research operations, and preserve its historic architecture features.\n\nThe major elements of work include, but are not limited to, the following:\n\n• Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.\n\n• Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.\n\n• Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.\n\n• Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.\n\n• Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.\n\n• Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.\n\n• Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.\n\n• Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.\n\n• Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.\n\nAll work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.\n\nPRE-BID TOUR OF THE SITE\n\nThe Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.\n\nREQUEST FOR CLARIFICATIONS\n\nIt is requested that all questions be sent in no later than April 14, 2026.\n\nTHE PROPOSAL DUE DATE IS TUESDAY, MAY 12, 2026, at 3:00 PM EASTERN STANDARD TIME (EST).\n\nThe subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).\n\nDavis Bacon Building Wage Determination DC20260002 shall apply.\n\nThe Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to Proceed.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"33330226RF0010002","place_of_performance":{"zip":"20560","state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1JA"},{"dates":{"posted":"2026-04-21","posted_at":"2026-04-21T16:57:11.237Z","created_at":"2026-04-21T16:52:59.941Z","modified_at":"2026-06-19T03:55:46.378Z","response_deadline":{"raw":"2026-05-20T15:00:00-04:00","utc":"2026-05-20T19:00:00Z","date":"2026-05-20","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/550b7638a6d04a43971f2541e7113f5d/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_id":"100188266","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-04","archive_type":"auto15"},"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"550b7638a6d04a43971f2541e7113f5d","lineage_id":"6c747abf197b44d6a77f634681c5a389","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T07:45:37.316334336Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"c725cf48cfc1238ad9791bfa75c66814fb8be863a7f1f52bf558dc954a3f0a1d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T07:45:37.316334336Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p><strong>Amendment 0002 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:</strong></p>\n\n<p><strong>2nd Site Visit&nbsp;</strong></p>\n\n<p><strong>RFI Due Date Extension</strong></p>\n\n<p><strong>Bid Due Date Extension</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:</strong></p>\n\n<p><strong>03/27 Site Visit Sign-in Sheet</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p>The Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution&#39;s National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.</p>\n\n<p>All of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.</p>\n\n<p>The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum&rsquo;s collections, exhibits, and research operations, and preserve its historic architecture features.</p>\n\n<p>The major elements of work include, but are not limited to, the following:</p>\n\n<ul>\n\t<li>Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.</li>\n\t<li>Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.</li>\n\t<li>Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.</li>\n\t<li>Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.</li>\n\t<li>Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.</li>\n\t<li>Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.</li>\n\t<li>Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.</li>\n\t<li>Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.</li>\n\t<li>Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.</li>\n</ul>\n\n<p>All work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.</p>\n\n<p></p>\n\n<p><strong>PRE-BID TOUR OF THE SITE</strong></p>\n\n<p>The Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.</p>\n\n<p><strong>REQUEST FOR CLARIFICATIONS</strong></p>\n\n<p>It is requested that all questions be sent in no later than April 14, 2026.</p>\n\n<p></p>\n\n<p><strong>THE PROPOSAL DUE DATE IS </strong><strong>TUESDAY, MAY 12, 2026, at 3:00 PM </strong><strong>EASTERN STANDARD TIME (EST).</strong></p>\n\n<p></p>\n\n<p>The subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).</p>\n\n<p>Davis Bacon Building Wage Determination DC20260002 shall apply.</p>\n\n<p>The Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to&nbsp;&nbsp; Proceed.</p>","text":"Amendment 0002 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:\n\n2nd Site Visit\n\nRFI Due Date Extension\n\nBid Due Date Extension\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:\n\n03/27 Site Visit Sign-in Sheet\n\n---------------------------------------------------------------------------------------------------------\n\nThe Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution's National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.\n\nAll of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.\n\nThe scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum’s collections, exhibits, and research operations, and preserve its historic architecture features.\n\nThe major elements of work include, but are not limited to, the following:\n\n• Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.\n\n• Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.\n\n• Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.\n\n• Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.\n\n• Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.\n\n• Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.\n\n• Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.\n\n• Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.\n\n• Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.\n\nAll work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.\n\nPRE-BID TOUR OF THE SITE\n\nThe Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.\n\nREQUEST FOR CLARIFICATIONS\n\nIt is requested that all questions be sent in no later than April 14, 2026.\n\nTHE PROPOSAL DUE DATE IS TUESDAY, MAY 12, 2026, at 3:00 PM EASTERN STANDARD TIME (EST).\n\nThe subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).\n\nDavis Bacon Building Wage Determination DC20260002 shall apply.\n\nThe Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to Proceed.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"33330226RF0010002","place_of_performance":{"zip":"20560","state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1JA"},{"dates":{"posted":"2026-04-28","posted_at":"2026-04-28T17:52:27.816Z","created_at":"2026-04-28T17:43:14.336Z","modified_at":"2026-06-19T03:55:46.378Z","response_deadline":{"raw":"2026-05-20T15:00:00-04:00","utc":"2026-05-20T19:00:00Z","date":"2026-05-20","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ce4c4b6bdfb84efa9905cc814d45dcff/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_id":"100188266","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-04","archive_type":"auto15"},"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ce4c4b6bdfb84efa9905cc814d45dcff","lineage_id":"6c747abf197b44d6a77f634681c5a389","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T00:48:31.136087177Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"dd558bda40d971789804f520538d26abc7adae7dc2d2f7461a6da00190edfd78","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T00:48:31.136087177Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p><strong>Amendment 0003 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:</strong></p>\n\n<p><strong>Responses to RFI&rsquo;s for Questions 1-75</strong></p>\n\n<p><strong>Updated Multi-Year Document &nbsp;</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0002 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:</strong></p>\n\n<p><strong>2nd Site Visit&nbsp;</strong></p>\n\n<p><strong>RFI Due Date Extension</strong></p>\n\n<p><strong>Bid Due Date Extension</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:</strong></p>\n\n<p><strong>03/27 Site Visit Sign-in Sheet</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p>The Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution&#39;s National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.</p>\n\n<p>All of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.</p>\n\n<p>The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum&rsquo;s collections, exhibits, and research operations, and preserve its historic architecture features.</p>\n\n<p>The major elements of work include, but are not limited to, the following:</p>\n\n<ul>\n\t<li>Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.</li>\n\t<li>Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.</li>\n\t<li>Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.</li>\n\t<li>Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.</li>\n\t<li>Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.</li>\n\t<li>Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.</li>\n\t<li>Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.</li>\n\t<li>Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.</li>\n\t<li>Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.</li>\n</ul>\n\n<p>All work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.</p>\n\n<p></p>\n\n<p><strong>PRE-BID TOUR OF THE SITE</strong></p>\n\n<p>The Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.</p>\n\n<p><strong>REQUEST FOR CLARIFICATIONS</strong></p>\n\n<p>It is requested that all questions be sent in no later than April 14, 2026.</p>\n\n<p></p>\n\n<p><strong>THE PROPOSAL DUE DATE IS </strong><strong>TUESDAY, MAY 12, 2026, at 3:00 PM </strong><strong>EASTERN STANDARD TIME (EST).</strong></p>\n\n<p></p>\n\n<p>The subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).</p>\n\n<p>Davis Bacon Building Wage Determination DC20260002 shall apply.</p>\n\n<p>The Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to&nbsp;&nbsp; Proceed.</p>","text":"Amendment 0003 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:\n\nResponses to RFI’s for Questions 1-75\n\nUpdated Multi-Year Document\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0002 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:\n\n2nd Site Visit\n\nRFI Due Date Extension\n\nBid Due Date Extension\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:\n\n03/27 Site Visit Sign-in Sheet\n\n---------------------------------------------------------------------------------------------------------\n\nThe Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution's National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.\n\nAll of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.\n\nThe scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum’s collections, exhibits, and research operations, and preserve its historic architecture features.\n\nThe major elements of work include, but are not limited to, the following:\n\n• Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.\n\n• Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.\n\n• Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.\n\n• Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.\n\n• Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.\n\n• Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.\n\n• Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.\n\n• Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.\n\n• Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.\n\nAll work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.\n\nPRE-BID TOUR OF THE SITE\n\nThe Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.\n\nREQUEST FOR CLARIFICATIONS\n\nIt is requested that all questions be sent in no later than April 14, 2026.\n\nTHE PROPOSAL DUE DATE IS TUESDAY, MAY 12, 2026, at 3:00 PM EASTERN STANDARD TIME (EST).\n\nThe subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).\n\nDavis Bacon Building Wage Determination DC20260002 shall apply.\n\nThe Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to Proceed.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"33330226RF0010002","place_of_performance":{"zip":"20560","state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1JA"},{"dates":{"posted":"2026-05-07","posted_at":"2026-05-07T19:36:50.548Z","created_at":"2026-05-07T19:33:58.694Z","modified_at":"2026-06-19T03:55:46.378Z","response_deadline":{"raw":"2026-05-20T15:00:00-04:00","utc":"2026-05-20T19:00:00Z","date":"2026-05-20","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/71e34bf1f66243aca63cc863030a0288/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_id":"100188266","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-04","archive_type":"auto15"},"history":[{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"71e34bf1f66243aca63cc863030a0288","lineage_id":"6c747abf197b44d6a77f634681c5a389","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-05T02:25:17.211658408Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"6c6a14df4aeb8f9173878f8f7e2a12058500e8be90396f69800c6fcf19dc08f0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-05T02:25:17.211658408Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p><strong>Amendment 0004 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:</strong></p>\n\n<p><strong>Presentation Slides</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0003 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:</strong></p>\n\n<p><strong>Responses to RFI&rsquo;s for Questions 1-75</strong></p>\n\n<p><strong>Updated Multi-Year Document &nbsp;</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0002 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:</strong></p>\n\n<p><strong>2nd Site Visit&nbsp;</strong></p>\n\n<p><strong>RFI Due Date Extension</strong></p>\n\n<p><strong>Bid Due Date Extension</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:</strong></p>\n\n<p><strong>03/27 Site Visit Sign-in Sheet</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p>The Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution&#39;s National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.</p>\n\n<p>All of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.</p>\n\n<p>The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum&rsquo;s collections, exhibits, and research operations, and preserve its historic architecture features.</p>\n\n<p>The major elements of work include, but are not limited to, the following:</p>\n\n<ul>\n\t<li>Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.</li>\n\t<li>Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.</li>\n\t<li>Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.</li>\n\t<li>Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.</li>\n\t<li>Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.</li>\n\t<li>Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.</li>\n\t<li>Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.</li>\n\t<li>Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.</li>\n\t<li>Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.</li>\n</ul>\n\n<p>All work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.</p>\n\n<p></p>\n\n<p><strong>PRE-BID TOUR OF THE SITE</strong></p>\n\n<p>The Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.</p>\n\n<p><strong>REQUEST FOR CLARIFICATIONS</strong></p>\n\n<p>It is requested that all questions be sent in no later than April 14, 2026.</p>\n\n<p></p>\n\n<p><strong>THE PROPOSAL DUE DATE IS </strong><strong>TUESDAY, MAY 12, 2026, at 3:00 PM </strong><strong>EASTERN STANDARD TIME (EST).</strong></p>\n\n<p></p>\n\n<p>The subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).</p>\n\n<p>Davis Bacon Building Wage Determination DC20260002 shall apply.</p>\n\n<p>The Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to&nbsp;&nbsp; Proceed.</p>","text":"Amendment 0004 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:\n\nPresentation Slides\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0003 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:\n\nResponses to RFI’s for Questions 1-75\n\nUpdated Multi-Year Document\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0002 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:\n\n2nd Site Visit\n\nRFI Due Date Extension\n\nBid Due Date Extension\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:\n\n03/27 Site Visit Sign-in Sheet\n\n---------------------------------------------------------------------------------------------------------\n\nThe Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution's National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.\n\nAll of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.\n\nThe scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum’s collections, exhibits, and research operations, and preserve its historic architecture features.\n\nThe major elements of work include, but are not limited to, the following:\n\n• Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.\n\n• Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.\n\n• Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.\n\n• Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.\n\n• Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.\n\n• Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.\n\n• Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.\n\n• Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.\n\n• Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.\n\nAll work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.\n\nPRE-BID TOUR OF THE SITE\n\nThe Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.\n\nREQUEST FOR CLARIFICATIONS\n\nIt is requested that all questions be sent in no later than April 14, 2026.\n\nTHE PROPOSAL DUE DATE IS TUESDAY, MAY 12, 2026, at 3:00 PM EASTERN STANDARD TIME (EST).\n\nThe subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).\n\nDavis Bacon Building Wage Determination DC20260002 shall apply.\n\nThe Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to Proceed.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"33330226RF0010002","place_of_performance":{"zip":"20560","state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1JA"},{"dates":{"posted":"2026-05-14","posted_at":"2026-05-14T19:43:00.853Z","created_at":"2026-05-14T18:43:10.737Z","modified_at":"2026-06-19T03:55:46.378Z","response_deadline":{"raw":"2026-06-03T15:00:00-04:00","utc":"2026-06-03T19:00:00Z","date":"2026-06-03","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/19b29af3d3bf4e5cb754d96ab7e7837e/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_id":"100188266","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-06-18","archive_type":"auto15"},"history":[{"index":9,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T13:10:45.742Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"1278ddd2547644cdaf945d8e8496c718","solicitation_number":"33330226CF0010408","related_opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e"},{"index":8,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":6,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-07T19:36:50.548Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"71e34bf1f66243aca63cc863030a0288","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":5,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-28T17:52:27.816Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"ce4c4b6bdfb84efa9905cc814d45dcff","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":4,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-21T16:57:11.237Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"550b7638a6d04a43971f2541e7113f5d","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-02T19:27:12.370Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"b07dcb24f13242788352a09b33825667","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-12T12:01:16.547Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"6c747abf197b44d6a77f634681c5a389","solicitation_number":"33330226RF0010002","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"},{"index":1,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-20T14:50:54.559Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc","solicitation_number":"33330226RF0010002","parent_opportunity_id":"71e593271c52429e9ed018da49afadec"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"19b29af3d3bf4e5cb754d96ab7e7837e","lineage_id":"6c747abf197b44d6a77f634681c5a389","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-04T01:16:58.566769436Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"e6628684457ea3e4a4481bba68d67ff1b3fceccd04445546755afc5a0eb71485","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-04T01:16:58.566769436Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p><strong>Amendment 0005 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:</strong></p>\n\n<p><strong>Responses to RFIs for Questions 76-82</strong></p>\n\n<p><strong>Addendum #1</strong></p>\n\n<p><strong>Bid Due Date Extension</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0004 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:</strong></p>\n\n<p><strong>Presentation Slides</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0003 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:</strong></p>\n\n<p><strong>Responses to RFI&rsquo;s for Questions 1-75</strong></p>\n\n<p><strong>Updated Multi-Year Document &nbsp;</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0002 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:</strong></p>\n\n<p><strong>2nd Site Visit&nbsp;</strong></p>\n\n<p><strong>RFI Due Date Extension</strong></p>\n\n<p><strong>Bid Due Date Extension</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p><strong>Amendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:</strong></p>\n\n<p><strong>03/27 Site Visit Sign-in Sheet</strong></p>\n\n<p><strong>---------------------------------------------------------------------------------------------------------</strong></p>\n\n<p>The Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution&#39;s National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.</p>\n\n<p>All of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.</p>\n\n<p>The scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum&rsquo;s collections, exhibits, and research operations, and preserve its historic architecture features.</p>\n\n<p>The major elements of work include, but are not limited to, the following:</p>\n\n<ul>\n\t<li>Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.</li>\n\t<li>Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.</li>\n\t<li>Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.</li>\n\t<li>Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.</li>\n\t<li>Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.</li>\n\t<li>Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.</li>\n\t<li>Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.</li>\n\t<li>Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.</li>\n\t<li>Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.</li>\n</ul>\n\n<p>All work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.</p>\n\n<p></p>\n\n<p><strong>PRE-BID TOUR OF THE SITE</strong></p>\n\n<p>The Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.</p>\n\n<p><strong>REQUEST FOR CLARIFICATIONS</strong></p>\n\n<p>It is requested that all questions be sent in no later than April 14, 2026.</p>\n\n<p></p>\n\n<p><strong>THE PROPOSAL DUE DATE IS </strong><strong>TUESDAY, MAY 12, 2026, at 3:00 PM </strong><strong>EASTERN STANDARD TIME (EST).</strong></p>\n\n<p></p>\n\n<p>The subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).</p>\n\n<p>Davis Bacon Building Wage Determination DC20260002 shall apply.</p>\n\n<p>The Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to&nbsp;&nbsp; Proceed.</p>","text":"Amendment 0005 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:\n\nResponses to RFIs for Questions 76-82\n\nAddendum #1\n\nBid Due Date Extension\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0004 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:\n\nPresentation Slides\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0003 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:\n\nResponses to RFI’s for Questions 1-75\n\nUpdated Multi-Year Document\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0002 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following changes to the Solicitation:\n\n2nd Site Visit\n\nRFI Due Date Extension\n\nBid Due Date Extension\n\n---------------------------------------------------------------------------------------------------------\n\nAmendment 0001 to the RFP is hereby issued and attached for download. The purpose of the amendment is to make the following change to the Solicitation:\n\n03/27 Site Visit Sign-in Sheet\n\n---------------------------------------------------------------------------------------------------------\n\nThe Smithsonian Institution is seeking offers to upgrade Sanitary and Storm Systems project at the Smithsonian Institution's National Museum of Natural History located at 10th Street and Constitution Avenue NW, Washington, DC, as described herein and the Contract Documents, including, without limitation, in the Specifications and Drawings for SF Project No. 1600103 both dated December 5, 2025.\n\nAll of the requirements which the successful Offeror must meet concerning this project are set forth in detail in the solicitation Documents included with this Request for Proposal. Upon receipt of Technical and Cost Proposals and the selection of a successful Offeror, the Smithsonian Institution will execute a Fixed Price construction contract. The Smithsonian currently estimates that the fixed price for the entire project will exceed $10 Million.\n\nThe scope of this project includes the installation of a new sanitary and stormwater system throughout the Museum Main Building, East and West Wings to replace the existing infrastructure that has reached the end of its service life. Work must be executed with extreme care to protect the museum’s collections, exhibits, and research operations, and preserve its historic architecture features.\n\nThe major elements of work include, but are not limited to, the following:\n\n• Installation of new sanitary and stormwater piping systems through the Main Building, East and West Wings in accordance with construction documents.\n\n• Rerouting stormwater and sanitary piping where possible to avoid passage through the ceiling of exhibit halls, collection storage areas, and other sensitive or restricted spaces.\n\n• Capping off abandoned piping, where feasible, isolating it from active systems and preventing future infiltration or structural compromise.\n\n• Removal and disposal of old piping where capping is not feasible, in compliance with environmental regulations and structural safety standards.\n\n• Lead and asbestos abatement, as necessary, in areas affected by demolition or pipe removal, in accordance with applicable EPA, OSHA, DOT, District of Columbia law and regulations and others as cited in the specification.\n\n• Installation of new sanitary and storm piping within the existing tunnel system, including structural support, penetrations, and insulation where required.\n\n• Tie-in of new systems to the existing SI stormwater and sanitary infrastructure external to the building, with proper alignment, connection materials, and testing.\n\n• Develop and implement a comprehensive erosion and sediment control plan in compliance with EPA Construction General Permit and District of Columbia regulations.\n\n• Inspect, remove and replace roof scuppers including sealing and integration with the building stormwater management system to restore proper drainage performance.\n\nAll work must be conducted in accordance with applicable codes, historic preservation requirements, safety regulations, and Smithsonian Institution design and construction standards. Phasing plans must minimize disruption to ongoing museum operations, protect the public, and preserve the integrity of historic and scientific assets.\n\nPRE-BID TOUR OF THE SITE\n\nThe Pre-proposal meeting is scheduled for Friday, March 27, 2026, at 9:00 AM Eastern Time.\n\nREQUEST FOR CLARIFICATIONS\n\nIt is requested that all questions be sent in no later than April 14, 2026.\n\nTHE PROPOSAL DUE DATE IS TUESDAY, MAY 12, 2026, at 3:00 PM EASTERN STANDARD TIME (EST).\n\nThe subcontracting goals for this project are: 40% with small business concerns. At least 7% with Service-Disabled Veteran-owned small businesses (SDV).\n\nDavis Bacon Building Wage Determination DC20260002 shall apply.\n\nThe Period of Performance for the Base Contract and Options 1-3, if exercised, is 740 Calendar Days from the date of Notice to Proceed.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"33330226RF0010002","place_of_performance":{"zip":"20560","state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1JA"},{"award":{"date":"2026-09-24","amount":"12034000.00","number":"33330226CF0010408","awardee":{"raw":"GRUNLEY CONSTRUCTION CO., INC. Rockville MD 20850 USA","uei":"R6CPWWDD4AM1","cage":"0MW40","name":"GRUNLEY CONSTRUCTION CO., INC.","location":{"zip":"20850","city":{"code":"67675","name":"Rockville"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-09-29","posted_at":"2026-09-29T13:10:45.742Z","award_date":"2026-09-24","created_at":"2026-09-29T13:03:35.193Z","modified_at":"2026-09-29T13:10:45.744Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/1278ddd2547644cdaf945d8e8496c718/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","agency":{"office":{"code":"333302","name":"SMITHSONIAN INSTITUTION"},"subtier":{"code":"3300","name":"SMITHSONIAN INSTITUTION"},"department":{"code":"033","name":"SMITHSONIAN INSTITUTION"},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-10-09","archive_type":"auto15"},"history":[{"index":3,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-29T13:10:45.742Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"1278ddd2547644cdaf945d8e8496c718","solicitation_number":"33330226CF0010408","related_opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e"},{"index":2,"title":"Upgrade Sanitary and Storm Systems at the National Museum of Natural History","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-14T19:43:00.853Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"19b29af3d3bf4e5cb754d96ab7e7837e","solicitation_number":"33330226RF0010002","parent_opportunity_id":"6c747abf197b44d6a77f634681c5a389","related_opportunity_id":"85e7d813bb344bf59fec90ac56e2dbcc"}],"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"1278ddd2547644cdaf945d8e8496c718","lineage_id":"6c747abf197b44d6a77f634681c5a389","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-30T08:45:44.841513628Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"02b3cf5ef9cca2e5ee7cd68d8719d93f9f9c8523c8633f6c6cb173fbff050d7d","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-30T04:12:42.529040938Z"},"description":{"html":"<p>Thank you for your efforts in submitting a proposal in response to the subject Solicitation. This notice is to inform you that Smithsonian has made an award to the following offeror:</p>\n\n<p></p>\n\n<p>Grunley Construction Co., Inc.</p>\n\n<p>15020 Shady Grove RD STE 500</p>\n\n<p>Rockville, Maryland 20850</p>\n\n<p></p>","text":"Thank you for your efforts in submitting a proposal in response to the subject Solicitation. This notice is to inform you that Smithsonian has made an award to the following offeror:\n\nGrunley Construction Co., Inc.\n\n15020 Shady Grove RD STE 500\n\nRockville, Maryland 20850","origin":"detail"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"33330226CF0010408","place_of_performance":{"zip":"20560","state":{"code":"DC"},"country":{"code":"USA"}},"product_service_code":"Y1JA"}],"due_at":"2026-06-03T19:00:00Z","due_date":"2026-06-03","closes_at":"2026-06-03T19:00:00Z","awardable":false,"dept_key":"d-033","dept_name":"SMITHSONIAN INSTITUTION","sub_key":"s-3300","sub_name":"SMITHSONIAN INSTITUTION","office_key":"o-333302","office_name":"SMITHSONIAN INSTITUTION","state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"R6CPWWDD4AM1","amount":"12034000.00","linked_awards":9,"cancelled":false,"archived":true,"updated_at":"2026-10-10T04:53:21.631701Z","principal_notice_id":"1278ddd2547644cdaf945d8e8496c718","description":{"text":"Thank you for your efforts in submitting a proposal in response to the subject Solicitation. This notice is to inform you that Smithsonian has made an award to the following offeror:\n\nGrunley Construction Co., Inc.\n\n15020 Shady Grove RD STE 500\n\nRockville, Maryland 20850","html":"<p>Thank you for your efforts in submitting a proposal in response to the subject Solicitation. This notice is to inform you that Smithsonian has made an award to the following offeror:</p>\n\n<p></p>\n\n<p>Grunley Construction Co., Inc.</p>\n\n<p>15020 Shady Grove RD STE 500</p>\n\n<p>Rockville, Maryland 20850</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Virginia Chan","role":"primary","email":"Chanvc@si.edu"},{"name":"Christine Grant","role":"secondary","email":"grantCA@si.edu"}],"place_of_performance":{"zip":"20560","state":{"code":"DC"},"country":{"code":"USA"}},"office_address":{"zip":"22202","city":"ARLINGTON","state":"VA","country":"USA"},"naics_codes":["236220"],"award":{"date":"2026-09-24","amount":"12034000.00","number":"33330226CF0010408","awardee":{"raw":"GRUNLEY CONSTRUCTION CO., INC. Rockville MD 20850 USA","uei":"R6CPWWDD4AM1","cage":"0MW40","name":"GRUNLEY CONSTRUCTION CO., INC.","location":{"zip":"20850","city":{"code":"67675","name":"Rockville"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}}}},"attachments":[{"resource_id":"68b1bb2310b44e629c041297c222f5f9","name":"Release of Claim Form.pdf","kind":"file","mime_type":".pdf","size_bytes":7084,"posted_at":"2026-03-12T12:01:16.547Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/68b1bb2310b44e629c041297c222f5f9/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_33330226CF0010408_3300_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_33330226CF0010408_3300_-NONE-_-NONE-/","piid":"33330226CF0010408","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"R6CPWWDD4AM1","recipient_name":"GRUNLEY CONSTRUCTION CO., INC.","recipient_uei":"R6CPWWDD4AM1","recipient_cage":"0MW40","recipient_city":"ROCKVILLE","recipient_state":"MD","sub_name":"Smithsonian Institution","office_name":"SMITHSONIAN INSTITUTION","office_key":"o-333302","first_action_date":"2026-09-24","last_action_date":"2026-10-16","actions":2,"obligated":"29213000.00","current_total_value":"29213000.00","potential_total_value":"29213000.00","naics":"236220","psc":"Y1JA","extent_competed":"FULL AND OPEN COMPETITION","set_aside":"NO SET ASIDE USED.","offers_received":1,"description":"NMNH: UPGRADE SANITARY AND STORM SYSTEMS","method":"solicitation","confidence":"high","evidence":["solicitation number 33330226RF0010002 equals the FPDS solicitation identifier","same awarding office 333302"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"33330227RF0010025","latest_notice_id":"6543257e0c4e49059daf554deecf5134","title":"NMAH: 2027 Install Emergency Generator","solicitation_number":"33330227RF0010025","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2027-02-10T20:00:00Z","due_date":"2027-02-10","closes_at":"2027-02-10T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-033","dept_name":"SMITHSONIAN INSTITUTION","sub_key":"s-3300","sub_name":"SMITHSONIAN INSTITUTION","office_key":"o-333302","office_name":"SMITHSONIAN INSTITUTION","naics":"236220","psc":"Z1JA","set_aside":null,"state":"DC","county":"11001","county_name":"District of Columbia","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":true,"removed_at":null,"updated_at":"2026-11-23T06:19:14.199153Z"}],"similar_open":[{"key":"W912DR27H1CWY","latest_notice_id":"52cced4ea8b3445898cde4032471d84e","title":"Capitol Perimeter Enhancements (CPE) Design-Build Construction Project","solicitation_number":"W912DR27H1CWY","notice_type":"r","first_type":"r","first_posted":"2026-11-13","last_posted":"2026-11-13","notices":1,"due_at":"2026-12-04T16:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912DR","office_name":"W2SD ENDIST BALTIMORE","naics":"236220","psc":"Y1PZ","set_aside":null,"state":"DC","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"ARCHITECT OF THE CAPITOL, WASHINGTON DC","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-14T05:16:40.707321Z"},{"key":"2031ZA26R00027","latest_notice_id":"1744af7270c241aa8625a14fa869de1c","title":"Cooling Tower, Roofing, and Structural Construction","solicitation_number":"2031ZA26R00027","notice_type":"o","first_type":"o","first_posted":"2026-09-16","last_posted":"2026-11-12","notices":4,"due_at":"2026-12-11T18:00:00Z","due_date":"2026-12-11","closes_at":"2026-12-11T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-020","dept_name":"TREASURY, DEPARTMENT OF THE","sub_key":"s-2041","sub_name":"BUREAU OF ENGRAVING AND PRINTING","office_key":"o-2031ZA","office_name":"OFFICE OF THE CHIEF PROCUREMENT OFFICER","naics":"236220","psc":"Z2EC","set_aside":"SBA","state":"DC","county":"11001","county_name":"District of Columbia","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"36C10F27R0003","latest_notice_id":"50c4c2b25d464578b63d996a3ad96e9f","title":"Y1JZ--Indefinite Delivery Indefinite Quantity (IDIQ) Design-Build & Construction Multiple Award Task Order Contract (MATOC) National VA Healthcare Construction Program","solicitation_number":"36C10F27R0003","notice_type":"o","first_type":"p","first_posted":"2026-10-14","last_posted":"2026-11-24","notices":8,"due_at":"2027-01-15T20:00:00Z","due_date":"2027-01-15","closes_at":"2027-01-15T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10F","office_name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)","naics":"236220","psc":"Y1JZ","set_aside":"SBP","state":"DC","county":"11001","county_name":"District of Columbia","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":191,"indexable":false}