{"canonical":"https://sealedbidder.com/opportunities/30252pr260000011","key":"30252PR260000011","url":"https://sealedbidder.com/opportunities/30252pr260000011","title":"HVAC Replacement at USCG STA Washington","solicitation_number":"30252PR260000011","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-30T16:00:00Z","first_posted":"2026-04-23","last_posted":"2026-04-23","department":"HOMELAND SECURITY, DEPARTMENT OF","subagency":"US COAST GUARD","office":"BASE NATIONAL CAPITAL REGION(000G8)","naics":"238220","psc":"N041","set_aside":"SBA","place_state":"DC","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"11001","place_county_name":"District of Columbia","place_city":null,"place_city_name":null,"winner":"CELLULAR SITE SERVICES, LLC","award_amount":null,"publications":[{"notice_id":"5af279c064bc4bbdab82ba136888fa1b","title":"HVAC Replacement at USCG STA Washington","solicitation_number":"30252PR260000011","notice_type":"k","base_type":"k","posted":"2026-04-23","posted_at":"2026-04-23T15:24:56.718Z","due_at":"2026-04-30T16:00:00Z","due_date":"2026-04-30","cancelled":false,"archived":true,"archive_date":"2026-05-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5af279c064bc4bbdab82ba136888fa1b/view","enriched":true,"history":[{"index":3,"title":"HVAC Replacement at USCG STA Washington","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-23T15:24:56.718Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5af279c064bc4bbdab82ba136888fa1b","solicitation_number":"30252PR260000011"}]}],"latest_notice_id":"5af279c064bc4bbdab82ba136888fa1b","first_type":"k","notices":[{"dates":{"posted":"2026-04-23","posted_at":"2026-04-23T15:24:56.718Z","created_at":"2026-04-23T15:02:16.732Z","modified_at":"2026-05-16T03:55:44.084Z","response_deadline":{"raw":"2026-04-30T12:00:00-04:00","utc":"2026-04-30T16:00:00Z","date":"2026-04-30","time":"12:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5af279c064bc4bbdab82ba136888fa1b/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"HVAC Replacement at USCG STA Washington","agency":{"office":{"code":"70Z0G8","name":"BASE NATIONAL CAPITAL REGION(000G8)"},"subtier":{"code":"7008","name":"US COAST GUARD"},"department":{"code":"070","name":"HOMELAND SECURITY, DEPARTMENT OF"},"office_address":{"zip":"20593","city":"WASHINGTON","state":"DC","country":"USA"},"organization_id":"100184901","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-15","archive_type":"auto15"},"history":[{"index":3,"title":"HVAC Replacement at USCG STA Washington","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-23T15:24:56.718Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"5af279c064bc4bbdab82ba136888fa1b","solicitation_number":"30252PR260000011"}],"contacts":[{"name":"Samuel Salerno","role":"primary","email":"Samuel.T.Salerno@uscg.mil","phone":"2068202120"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"5af279c064bc4bbdab82ba136888fa1b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"5af279c064bc4bbdab82ba136888fa1b","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T02:24:34.577796843Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"4501db938972f3df0ce692eca090a743170ab904369076b6b4486b7038905fea","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T02:24:34.577796843Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>HVAC replacemet in accordance with the Attached SOW, to include:</p>\n\n<p>a. Determine heat load calculations for the HVAC system using installed ducting system.&nbsp; Use heat load calculations to determine an appropriate size/capacity for indoor and outdoor units utilizing installed ducting. Provide owner with a written copy of load calculations. If it is determined that any duct work needs to be modified, changed or resized in any way due to the heat load calculations, contractor shall provide and install. New unit shall be EPA approved A2L based refrigerant either R-454B or R-32, preferably R-454B. Contractor shall pull and entire new line-set to include new suction lines and liquid lines that run from heat pump to air handler. Contractor shall install a new liquid line drier for each circuit and locate the new liquid line drier indoors near the air handler to prevent unnecessary corrosion from outside elements.</p>\n\n<p>b. Remove and dispose of the current outdoor and indoor units.&nbsp; Unit will not have refrigerant in it.</p>\n\n<p>c. Replace wiring and conduit from existing service disconnects to new pieces of equipment.&nbsp; Replace any corroded or damaged conduit or wiring found during the demo of existing equipment. If disconnects are not fused, then contractor shall replace any and all associated disconnects with new fused ones.</p>\n\n<p>d. Replace all thermostat control wiring inside and outside with new UV rated wire.&nbsp; Provide and replace existing thermostat to match the system function.&nbsp; &nbsp;</p>","text":"HVAC replacemet in accordance with the Attached SOW, to include:\n\na. Determine heat load calculations for the HVAC system using installed ducting system. Use heat load calculations to determine an appropriate size/capacity for indoor and outdoor units utilizing installed ducting. Provide owner with a written copy of load calculations. If it is determined that any duct work needs to be modified, changed or resized in any way due to the heat load calculations, contractor shall provide and install. New unit shall be EPA approved A2L based refrigerant either R-454B or R-32, preferably R-454B. Contractor shall pull and entire new line-set to include new suction lines and liquid lines that run from heat pump to air handler. Contractor shall install a new liquid line drier for each circuit and locate the new liquid line drier indoors near the air handler to prevent unnecessary corrosion from outside elements.\n\nb. Remove and dispose of the current outdoor and indoor units. Unit will not have refrigerant in it.\n\nc. Replace wiring and conduit from existing service disconnects to new pieces of equipment. Replace any corroded or damaged conduit or wiring found during the demo of existing equipment. If disconnects are not fused, then contractor shall replace any and all associated disconnects with new fused ones.\n\nd. Replace all thermostat control wiring inside and outside with new UV rated wire. Provide and replace existing thermostat to match the system function.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"30252PR260000011","place_of_performance":{"zip":"20032","city":{"code":"5100","name":"Bolling AFB"},"state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"N041"}],"due_at":"2026-04-30T16:00:00Z","due_date":"2026-04-30","closes_at":"2026-04-30T16:00:00Z","awardable":false,"dept_key":"d-070","dept_name":"HOMELAND SECURITY, DEPARTMENT OF","sub_key":"s-7008","sub_name":"US COAST GUARD","office_key":"o-70Z0G8","office_name":"BASE NATIONAL CAPITAL REGION(000G8)","state":"DC","county":"11001","county_name":"District of Columbia","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"DJ2KQM3NU5M6","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-10-06T02:50:06.214926Z","principal_notice_id":"5af279c064bc4bbdab82ba136888fa1b","description":{"text":"HVAC replacemet in accordance with the Attached SOW, to include:\n\na. Determine heat load calculations for the HVAC system using installed ducting system. Use heat load calculations to determine an appropriate size/capacity for indoor and outdoor units utilizing installed ducting. Provide owner with a written copy of load calculations. If it is determined that any duct work needs to be modified, changed or resized in any way due to the heat load calculations, contractor shall provide and install. New unit shall be EPA approved A2L based refrigerant either R-454B or R-32, preferably R-454B. Contractor shall pull and entire new line-set to include new suction lines and liquid lines that run from heat pump to air handler. Contractor shall install a new liquid line drier for each circuit and locate the new liquid line drier indoors near the air handler to prevent unnecessary corrosion from outside elements.\n\nb. Remove and dispose of the current outdoor and indoor units. Unit will not have refrigerant in it.\n\nc. Replace wiring and conduit from existing service disconnects to new pieces of equipment. Replace any corroded or damaged conduit or wiring found during the demo of existing equipment. If disconnects are not fused, then contractor shall replace any and all associated disconnects with new fused ones.\n\nd. Replace all thermostat control wiring inside and outside with new UV rated wire. Provide and replace existing thermostat to match the system function.","html":"<p>HVAC replacemet in accordance with the Attached SOW, to include:</p>\n\n<p>a. Determine heat load calculations for the HVAC system using installed ducting system.&nbsp; Use heat load calculations to determine an appropriate size/capacity for indoor and outdoor units utilizing installed ducting. Provide owner with a written copy of load calculations. If it is determined that any duct work needs to be modified, changed or resized in any way due to the heat load calculations, contractor shall provide and install. New unit shall be EPA approved A2L based refrigerant either R-454B or R-32, preferably R-454B. Contractor shall pull and entire new line-set to include new suction lines and liquid lines that run from heat pump to air handler. Contractor shall install a new liquid line drier for each circuit and locate the new liquid line drier indoors near the air handler to prevent unnecessary corrosion from outside elements.</p>\n\n<p>b. Remove and dispose of the current outdoor and indoor units.&nbsp; Unit will not have refrigerant in it.</p>\n\n<p>c. Replace wiring and conduit from existing service disconnects to new pieces of equipment.&nbsp; Replace any corroded or damaged conduit or wiring found during the demo of existing equipment. If disconnects are not fused, then contractor shall replace any and all associated disconnects with new fused ones.</p>\n\n<p>d. Replace all thermostat control wiring inside and outside with new UV rated wire.&nbsp; Provide and replace existing thermostat to match the system function.&nbsp; &nbsp;</p>","origin":"detail"},"contacts":[{"name":"Samuel Salerno","role":"primary","email":"Samuel.T.Salerno@uscg.mil","phone":"2068202120"}],"place_of_performance":{"zip":"20032","city":{"code":"5100","name":"Bolling AFB"},"state":{"code":"DC","name":"District of Columbia"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20593","city":"WASHINGTON","state":"DC","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"08586137ea3840119ba95c6620f49ac5","name":"FAR Clauses.pdf","kind":"file","mime_type":".pdf","size_bytes":378582,"posted_at":"2026-04-23T15:24:56.718Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/08586137ea3840119ba95c6620f49ac5/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_70Z0G826PBNCR0013_7008_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_70Z0G826PBNCR0013_7008_-NONE-_-NONE-/","piid":"70Z0G826PBNCR0013","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"DJ2KQM3NU5M6","recipient_name":"CELLULAR SITE SERVICES, LLC","recipient_uei":"DJ2KQM3NU5M6","recipient_cage":"22B39","recipient_city":"UPPER MARLBORO","recipient_state":"MD","sub_name":"U.S. Coast Guard","office_name":"BASE NATIONAL CAPITAL REGION(000G8)","office_key":"o-70Z0G8","first_action_date":"2026-07-20","last_action_date":"2026-07-20","actions":1,"obligated":"61830.00","current_total_value":"61830.00","potential_total_value":"61830.00","naics":"238220","psc":"J041","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":6,"description":"ENGINEERED HEAT LOAD CALCULATIONS TO DETERMINE CORRECT UNIT SIZE AND PLANNING FOR INSTALLATION. BUILDING 91 SECOND DECK HVAC - CEUC APPROVED","method":"solicitation","confidence":"high","evidence":["solicitation number 30252PR260000011 equals the FPDS solicitation identifier","same awarding office 70Z0G8"],"opportunity_key":null,"opportunity_title":null}],"related":[],"similar_open":[{"key":"W911PT27QA020","latest_notice_id":"084d5efc5ec44a9885a37b90e6705ffa","title":"REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS","solicitation_number":"W911PT27QA020","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"238220","psc":"Z2NB","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"IGH VELOCITY AIR HANDLING UNITSPROJECT LOCATION: WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"2031ZA27B00001","latest_notice_id":"622efd27a6cf48589063c08d3700b96b","title":"Modernize Regenerative Thermal Oxidizer (RTO)","solicitation_number":"2031ZA27B00001","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-020","dept_name":"TREASURY, DEPARTMENT OF THE","sub_key":"s-2041","sub_name":"BUREAU OF ENGRAVING AND PRINTING","office_key":"o-2031ZA","office_name":"OFFICE OF THE CHIEF PROCUREMENT OFFICER","naics":"238220","psc":"Z2AZ","set_aside":null,"state":"TX","county":"48439","county_name":"Tarrant County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":59,"indexable":false}