Presolicitation
3500XL Genetic analyzer
24-005892
National Institutes of Health, National Institutes of Health - CC. In-Vitro Diagnostic Substance Manufacturing.
Response deadline
March 22, 2024 at 12:00 PM EDT
Closed 980 days ago. Posted March 12, 2024. Scheduled to archive March 22, 2024.
Get the next one like this from National Institutes of Health by email, the day it is posted.Find my opportunities
This one closed in 2024
7 like it are open now in in-vitro diagnostic substance manufacturing
- FLOW CYTOMETERY REAGENTS AND SUPPLIES (VA-27-00016081) |
Department of Veterans Affairs, 245-Network Contract Office 5
Combined synopsis and solicitationNAICS 325413Ship to Baltimore, MD36C24527Q0070Due todayNov 27 - HEMOCHRON SIGNATURE ELITE REAGENTS AND SUPPLIES
Department of Veterans Affairs, 262-Network Contract Office 22
Combined synopsis and solicitationNAICS 325413Ship to Tucson, AZ36C26227Q0111Due todayNov 27 - 6550 Reagents Consumables Microbiology Testing Boise VAMC
Department of Veterans Affairs, 260-Network Contract Office 20
Due tomorrowNov 28
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Presolicitation. Advance notice that a solicitation is coming, usually within a few weeks. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 325413 (in-vitro diagnostic substance manufacturing), means no more than 1,250 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the presolicitation of March 12, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Notice of Intent 3500XL Genetic analyzer Product Service Code:
6515 NAICS Code: 325413 - (Not Small Business Size Standards- 1,250 Average Number of Employees)
Place of Performance:
Bethesda, MD 20892 USA POTS:
24-005892 Description: This is a notice of intent, not a request for a quotation. A solicitation document will not be issued, and quotations will not be requested. The Department of Laboratory Medicine (DLM) serves as the clinical laboratory of the, National Institutes of Health (NIH). Clinical Center. It provides laboratory support for patient care and research protocols and performs research and training in disciplines of Clinical Pathology.
In doing so it provides state-of-the-art laboratory testing in support of Clinical Center patient care and serves as a center of excellence in research and training in laboratory medicine, particularly in areas which utilize the unique strengths of the NIH.
The purpose of this requirement is to replace the existing ABI 3500 Genetic analyzer in DLM, Serial #26105-180 with a new 3500XL Genetic analyzer Life Technologies, Carlsbad, CA 92008 is uniquely qualified to replace the existing 3500XL Genetic Analyzer that is manufactured by Applied Biosystems, part of Thermo Fisher Scientific. Life Technologies is a subsidiary of Thermo Fisher and is the only known distributor of the compatible equipment.
Extensive research has produced no other capillary. electrophoresis systems with same capabilities that can resolve single nucleotide. polymorphisms and sequencing in this country.
Minimum Specifications •A 24-capillary, fluorescence-based capillary electrophoresis system used for genetic analysis. •The analyzer must be fully automated from polymer loading and replacement, DNA separation, detection and data analysis to generate base-called or size called results. •The analyzer must be built with a single-line 505nm, solid-state long- life laser that utilizes a standard power supply and requires no heat removal ducting and the thermal system is specifically designed to improve temperature control and can maintain temperatures from 18 to 70 degrees C. •The system should give significantly improved signal uniformity from instrument-to-instrument, run-to-run and capillary-to-capillary through the use of instrument normalization schemes. •The Analyzer should be able to detect and analyze six fluorescent dyes simultaneously for DNA fragment analysis. •Each of the primary consumables should be designed with a RFID (Radio Frequency Identification) tag integrated into the label.
These labels allow tracking and reporting of the consumable usage, lot and part numbers, expiration dates and on-instrument lifetime through the instrument operation software. •Include the most up-to-date sequencing analysis software for gene mapping and analysis. •Includes an installation kit.
This acquisition is being conducted using policies unique to the Federal Acquisition Regulation (FAR) Part 13 – Simplified Acquisition Procedures, Subpart 13.106-1(b)(1), For purchases not exceeding the simplified acquisition threshold (SAT), contracting officers may solicit from one source if the contracting officer determines that the circumstance of the contract action deem only one source reasonably available.
Contracts awarded using FAR Part 13-Simplified Acquisition Procedures are exempt from the requirements of FAR Part 6-Competition Requirements. Interested parties may identify their interest and capabilities in response to this posting. The determination by the Government not to compete the proposed requirement based upon responses to this notice is solely within the discretion of the Government.
Comments to this announcement, referencing this posting number, may be submitted to the Office of Purchasing and Contracts, prior to the closing date specified in this announcement, electronically to the attention of Damien Goines, Contract Specialist, damien.goines@nih.gov by , Friday March 22, 2024 12:00PM EST.
Please send your capability statements ONLY. This IS NOT a request for proposal.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
March 12, 2024
Presolicitation
Due March 22, 2024 at 12:00 PM EDT. SAM.gov, notice 6a5982fe866740bba6c511eb166d0b21
Points of contact
- Damien Goinesdamien.goines@nih.gov301-827-4879