Presolicitation
Emergency replacement of components within the grit facilities throughout the South Bay International Wastewater Treatment Plant (SBIWTP).
20244301006
International Boundary and Water Commission: US-Mexico, Internat. Boundary and Water Comm.. Sewage Treatment Facilities.
Status
Presolicitation
Posted July 24, 2024. Scheduled to archive August 30, 2024.
Get the next one like this from International Boundary and Water Commission: US-Mexico by email, the day it is posted.Find my opportunities
This one is not taking offers
4 like it are open now in sewage treatment facilities
- Operations and Maintenance (O&M) Services for the SBIWTP
International Boundary and Water Commission: US-Mexico, Internat. Boundary and Water Comm.
SolicitationNAICS 221320California191BWC26R0009Closes in 42 daysJan 6, 2027 - Station Grand Isle Sewage Treatment
US Coast Guard, Base New Orleans
SolicitationSmall businessNAICS 221320Grand Isle, LA70Z02927QNEWO0P01Due tomorrowNov 26 - GRCA 257282 - Replace Wastewater Plant at South Ri
National Park Service, DSC Contracting Services Division
SolicitationNAICS 221320Arizona140P2026R0101Closes in 23 daysDec 18
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Presolicitation. Advance notice that a solicitation is coming, usually within a few weeks. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 221320 (sewage treatment facilities), means no more than $35 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the presolicitation of July 24, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
The primary goal of this acquisition is to replace 3 Grit Classifiers, 6 Grit Gallery Pumps, 6 Grit Pump VFDs, 2 Primary Channel Air Blowers, and 2 Grit Air Blowers. There is also a requirement to conduct a Short Circuit Arc Flash Study. All components are past its life remaining operations, which could lead to partially treated sewage not meeting permit standards discharged through ocean outfall, leading to permit violations. The rehabilitation and replacements are required to maintain safe and reliable operations of SBIWTP.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 24, 2024
Presolicitation
SAM.gov, notice 366d66b7908a4821b64d6009d9c9f405
Points of contact
- Philip Johnsonphilip.johnson@ibwc.gov915-255-9324
- Seone Michael Jonesseone.jones@ibwc.gov