{"canonical":"https://sealedbidder.com/opportunities/19gv1025q0003","key":"19GV1025Q0003","url":"https://sealedbidder.com/opportunities/19gv1025q0003","title":"19GV1025Q0003 - INSPECTION, MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE, DIESEL GENERATORS","solicitation_number":"19GV1025Q0003","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-02-25T10:00:00Z","first_posted":"2025-01-22","last_posted":"2025-01-22","department":"STATE, DEPARTMENT OF","subagency":"STATE, DEPARTMENT OF","office":"U.S. EMBASSY CONAKRY","naics":"811310","psc":"H349","set_aside":null,"place_state":null,"place_scope":"overseas","site":null,"place_state_source":null,"place_evidence":"GUINEA","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":"MISCELLANEOUS FOREIGN AWARDEES","award_amount":null,"publications":[{"notice_id":"18a909868a294c96be062939b7e3903e","title":"19GV1025Q0003 - INSPECTION, MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE, DIESEL GENERATORS","solicitation_number":"19GV1025Q0003","notice_type":"o","base_type":"o","posted":"2025-01-22","posted_at":"2025-01-22T22:44:52.423Z","due_at":"2025-02-25T10:00:00Z","due_date":"2025-02-25","cancelled":false,"archived":true,"archive_date":"2025-03-12","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/18a909868a294c96be062939b7e3903e/view","enriched":true,"history":[{"index":3,"title":"19GV1025Q0003 - INSPECTION, MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE, DIESEL GENERATORS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-22T22:44:52.423Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"18a909868a294c96be062939b7e3903e","solicitation_number":"19GV1025Q0003"}]}],"latest_notice_id":"18a909868a294c96be062939b7e3903e","first_type":"o","notices":[{"dates":{"posted":"2025-01-22","posted_at":"2025-01-22T22:44:52.423Z","created_at":"2025-01-03T09:42:23.538Z","modified_at":"2025-03-13T03:55:46.061Z","response_deadline":{"raw":"2025-02-25T10:00:00+00:00","utc":"2025-02-25T10:00:00Z","date":"2025-02-25","time":"10:00:00","timezone":"Europe/London","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/18a909868a294c96be062939b7e3903e/view"},"naics":{"codes":["811310"],"primary":"811310"},"title":"19GV1025Q0003 - INSPECTION, MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE, DIESEL GENERATORS","agency":{"office":{"code":"19GV10","name":"U.S. EMBASSY CONAKRY"},"subtier":{"code":"1900","name":"STATE, DEPARTMENT OF"},"department":{"code":"019","name":"STATE, DEPARTMENT OF"},"office_address":{"zip":"20520","city":"WASHINGTON","state":"DC","country":"USA"},"organization_id":"100163834","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-03-12","archive_type":"auto15"},"history":[{"index":3,"title":"19GV1025Q0003 - INSPECTION, MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE, DIESEL GENERATORS","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-01-22T22:44:52.423Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"18a909868a294c96be062939b7e3903e","solicitation_number":"19GV1025Q0003"}],"contacts":[{"name":"Carpenter, Timothy R","role":"primary","email":"CarpenterTR1@state.gov","phone":"7712068323"},{"name":"MARAH FAMA","role":"secondary","email":"MarahF@state.gov","phone":"+224629000534"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"18a909868a294c96be062939b7e3903e","lineage_id":"18a909868a294c96be062939b7e3903e","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-24T11:24:45.765581662Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"b6ef6f7ccbeca37272cce3ff8c1eacc27b94a7cd1ac79dd53bb6f1bc3eb9b738","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-24T11:24:45.765581662Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p>REQUESTING OFFERS FOR THE INSPECTION, PREVENTIVE MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE DIESEL GENERATORS FOR THE EMBASSY OF THE UNITED STATES OF AMERICA IN CONAKRY, REPUBLIC OF GUINEA..&nbsp;</p>\n\n<p>THE GENERATORS&nbsp; AND RELATED EQUIPMENTS ARE AS FOLLOWS:</p>\n\n<p><strong><u>GEN SET #1</u></strong></p>\n\n<p>MAKE AND MODEL=CATERPILLAR CAT3512, SERIAL AND SPEC NUMBER = YAK000637; ENGINE SERIAL NUMBER AND SPEC = *1KZ04865*, GEN SET CONTROL PANEL MODEL NUMBER = EMCP4.2; ENGINE HOURS AND DATE = 10139.5; HOURS&nbsp; AND DATE OF LAST BATTERY CHANGE = 2024 (PLAN EVERY 3 YEARS); HOURS AND DATE OF LAST COOLANT CHANGE = 2022 (PLAN EVERY 3 YEARS OR 6 FOR ELC); HOURS AND DATE OF LAST VALVE LASH ADJUSTMENT = INITIAL AND ANNUALLY ; TOP END SERVICES PERFORMED = IN 2022;&nbsp; DAY TANK MAKE AND MODEL = TRAMONT ABOVE GRADE AST RECTANGULAR 600 GALONS WITH SERIAL NUMBER 89341103B</p>\n\n<p><strong>ATS#2 GENERATOR #1 TO GENERATOR #2 = ASCO 7000 SERIES; ATS#2 SERIAL NUMBER = 1657015-001 WE; AMPS = 3000; VOLTS = 400V 50-60HZ</strong></p>\n\n<p></p>\n\n<p><strong><u>GEN SET #2</u></strong></p>\n\n<p>MAKE AND MODEL = CATERPILLAR CAT 3512; SERIAL AND SPEC NUMBER = YAK000631; ENGINE SERIAL AND SPEC NUMBER = *IKZ04864*; GEN SET CONTROL PANEL MODEL NUMBER = EMCP4.2; ENGINE HOURS AND DATE = 12364.4; HOURS AND DATE OF LAST BATTERY CHANGE = 2022; HOURS AND DATE OF LAST COOLANT CHANGE = 2022; DAY TANK MAKE AND MODEL =&nbsp;TRAMONT ABOVE GRADE AST RECTANGULAR 600 GALONS WITH SERIAL NUMBER 89341103A</p>\n\n<p></p>\n\n<p><strong>ATS#4 U BUS GENERATOR TO UTILITY = ASCO 7000 SERIES; ATS#2 SERIAL NUMBER 1657015-002 WE; AMPS =3000; VOLTS = 400V 50-60HZ</strong></p>\n\n<p></p>\n\n<p><u><strong>GENSET # 3</strong></u></p>\n\n<p>MAKE AND MODEL = CAT 3456 / SR-4B; SERIAL AND SPEC NUMBER = CAT00000VCB01355;&nbsp;</p>\n\n<p></p>\n\n<p><strong><u>ATS CHANCERY GENERATOR ROOM</u></strong></p>\n\n<p>MAKE AND MODEL = ASCO 7000 SERIES;&nbsp;CHANCERY GENERATOR DAY TANK MAKE AND MODEL =&nbsp;TRAMONT ABOVE GRADE AST RECTANGULAR 300 GALONS WITH SERIAL NUMBER 116978</p>\n\n<p></p>\n\n<p></p>","text":"REQUESTING OFFERS FOR THE INSPECTION, PREVENTIVE MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE DIESEL GENERATORS FOR THE EMBASSY OF THE UNITED STATES OF AMERICA IN CONAKRY, REPUBLIC OF GUINEA..\n\nTHE GENERATORS AND RELATED EQUIPMENTS ARE AS FOLLOWS:\n\nGEN SET #1\n\nMAKE AND MODEL=CATERPILLAR CAT3512, SERIAL AND SPEC NUMBER = YAK000637; ENGINE SERIAL NUMBER AND SPEC = *1KZ04865*, GEN SET CONTROL PANEL MODEL NUMBER = EMCP4.2; ENGINE HOURS AND DATE = 10139.5; HOURS AND DATE OF LAST BATTERY CHANGE = 2024 (PLAN EVERY 3 YEARS); HOURS AND DATE OF LAST COOLANT CHANGE = 2022 (PLAN EVERY 3 YEARS OR 6 FOR ELC); HOURS AND DATE OF LAST VALVE LASH ADJUSTMENT = INITIAL AND ANNUALLY ; TOP END SERVICES PERFORMED = IN 2022; DAY TANK MAKE AND MODEL = TRAMONT ABOVE GRADE AST RECTANGULAR 600 GALONS WITH SERIAL NUMBER 89341103B\n\nATS#2 GENERATOR #1 TO GENERATOR #2 = ASCO 7000 SERIES; ATS#2 SERIAL NUMBER = 1657015-001 WE; AMPS = 3000; VOLTS = 400V 50-60HZ\n\nGEN SET #2\n\nMAKE AND MODEL = CATERPILLAR CAT 3512; SERIAL AND SPEC NUMBER = YAK000631; ENGINE SERIAL AND SPEC NUMBER = *IKZ04864*; GEN SET CONTROL PANEL MODEL NUMBER = EMCP4.2; ENGINE HOURS AND DATE = 12364.4; HOURS AND DATE OF LAST BATTERY CHANGE = 2022; HOURS AND DATE OF LAST COOLANT CHANGE = 2022; DAY TANK MAKE AND MODEL = TRAMONT ABOVE GRADE AST RECTANGULAR 600 GALONS WITH SERIAL NUMBER 89341103A\n\nATS#4 U BUS GENERATOR TO UTILITY = ASCO 7000 SERIES; ATS#2 SERIAL NUMBER 1657015-002 WE; AMPS =3000; VOLTS = 400V 50-60HZ\n\nGENSET # 3\n\nMAKE AND MODEL = CAT 3456 / SR-4B; SERIAL AND SPEC NUMBER = CAT00000VCB01355;\n\nATS CHANCERY GENERATOR ROOM\n\nMAKE AND MODEL = ASCO 7000 SERIES; CHANCERY GENERATOR DAY TANK MAKE AND MODEL = TRAMONT ABOVE GRADE AST RECTANGULAR 300 GALONS WITH SERIAL NUMBER 116978","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"19GV1025Q0003","place_of_performance":{"city":{"code":"CONAKRY","name":"CONAKRY"},"state":{"code":"GN-C","name":"Conakry"},"country":{"code":"GIN","name":"GUINEA"}},"product_service_code":"H349"}],"due_at":"2025-02-25T10:00:00Z","due_date":"2025-02-25","closes_at":"2025-02-25T10:00:00Z","awardable":false,"dept_key":"d-019","dept_name":"STATE, DEPARTMENT OF","sub_key":"s-1900","sub_name":"STATE, DEPARTMENT OF","office_key":"o-19GV10","office_name":"U.S. EMBASSY CONAKRY","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"GIN","state_source":null,"state_evidence":"GUINEA","site_key":null,"winner_key":"LN9PU5M2YZN5","amount":null,"linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-11-24T11:25:06.834763Z","principal_notice_id":"18a909868a294c96be062939b7e3903e","description":{"text":"REQUESTING OFFERS FOR THE INSPECTION, PREVENTIVE MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE DIESEL GENERATORS FOR THE EMBASSY OF THE UNITED STATES OF AMERICA IN CONAKRY, REPUBLIC OF GUINEA..\n\nTHE GENERATORS AND RELATED EQUIPMENTS ARE AS FOLLOWS:\n\nGEN SET #1\n\nMAKE AND MODEL=CATERPILLAR CAT3512, SERIAL AND SPEC NUMBER = YAK000637; ENGINE SERIAL NUMBER AND SPEC = *1KZ04865*, GEN SET CONTROL PANEL MODEL NUMBER = EMCP4.2; ENGINE HOURS AND DATE = 10139.5; HOURS AND DATE OF LAST BATTERY CHANGE = 2024 (PLAN EVERY 3 YEARS); HOURS AND DATE OF LAST COOLANT CHANGE = 2022 (PLAN EVERY 3 YEARS OR 6 FOR ELC); HOURS AND DATE OF LAST VALVE LASH ADJUSTMENT = INITIAL AND ANNUALLY ; TOP END SERVICES PERFORMED = IN 2022; DAY TANK MAKE AND MODEL = TRAMONT ABOVE GRADE AST RECTANGULAR 600 GALONS WITH SERIAL NUMBER 89341103B\n\nATS#2 GENERATOR #1 TO GENERATOR #2 = ASCO 7000 SERIES; ATS#2 SERIAL NUMBER = 1657015-001 WE; AMPS = 3000; VOLTS = 400V 50-60HZ\n\nGEN SET #2\n\nMAKE AND MODEL = CATERPILLAR CAT 3512; SERIAL AND SPEC NUMBER = YAK000631; ENGINE SERIAL AND SPEC NUMBER = *IKZ04864*; GEN SET CONTROL PANEL MODEL NUMBER = EMCP4.2; ENGINE HOURS AND DATE = 12364.4; HOURS AND DATE OF LAST BATTERY CHANGE = 2022; HOURS AND DATE OF LAST COOLANT CHANGE = 2022; DAY TANK MAKE AND MODEL = TRAMONT ABOVE GRADE AST RECTANGULAR 600 GALONS WITH SERIAL NUMBER 89341103A\n\nATS#4 U BUS GENERATOR TO UTILITY = ASCO 7000 SERIES; ATS#2 SERIAL NUMBER 1657015-002 WE; AMPS =3000; VOLTS = 400V 50-60HZ\n\nGENSET # 3\n\nMAKE AND MODEL = CAT 3456 / SR-4B; SERIAL AND SPEC NUMBER = CAT00000VCB01355;\n\nATS CHANCERY GENERATOR ROOM\n\nMAKE AND MODEL = ASCO 7000 SERIES; CHANCERY GENERATOR DAY TANK MAKE AND MODEL = TRAMONT ABOVE GRADE AST RECTANGULAR 300 GALONS WITH SERIAL NUMBER 116978","html":"<p>REQUESTING OFFERS FOR THE INSPECTION, PREVENTIVE MAINTENANCE AND REPAIR OF STANDBY, LOW VOLTAGE DIESEL GENERATORS FOR THE EMBASSY OF THE UNITED STATES OF AMERICA IN CONAKRY, REPUBLIC OF GUINEA..&nbsp;</p>\n\n<p>THE GENERATORS&nbsp; AND RELATED EQUIPMENTS ARE AS FOLLOWS:</p>\n\n<p><strong><u>GEN SET #1</u></strong></p>\n\n<p>MAKE AND MODEL=CATERPILLAR CAT3512, SERIAL AND SPEC NUMBER = YAK000637; ENGINE SERIAL NUMBER AND SPEC = *1KZ04865*, GEN SET CONTROL PANEL MODEL NUMBER = EMCP4.2; ENGINE HOURS AND DATE = 10139.5; HOURS&nbsp; AND DATE OF LAST BATTERY CHANGE = 2024 (PLAN EVERY 3 YEARS); HOURS AND DATE OF LAST COOLANT CHANGE = 2022 (PLAN EVERY 3 YEARS OR 6 FOR ELC); HOURS AND DATE OF LAST VALVE LASH ADJUSTMENT = INITIAL AND ANNUALLY ; TOP END SERVICES PERFORMED = IN 2022;&nbsp; DAY TANK MAKE AND MODEL = TRAMONT ABOVE GRADE AST RECTANGULAR 600 GALONS WITH SERIAL NUMBER 89341103B</p>\n\n<p><strong>ATS#2 GENERATOR #1 TO GENERATOR #2 = ASCO 7000 SERIES; ATS#2 SERIAL NUMBER = 1657015-001 WE; AMPS = 3000; VOLTS = 400V 50-60HZ</strong></p>\n\n<p></p>\n\n<p><strong><u>GEN SET #2</u></strong></p>\n\n<p>MAKE AND MODEL = CATERPILLAR CAT 3512; SERIAL AND SPEC NUMBER = YAK000631; ENGINE SERIAL AND SPEC NUMBER = *IKZ04864*; GEN SET CONTROL PANEL MODEL NUMBER = EMCP4.2; ENGINE HOURS AND DATE = 12364.4; HOURS AND DATE OF LAST BATTERY CHANGE = 2022; HOURS AND DATE OF LAST COOLANT CHANGE = 2022; DAY TANK MAKE AND MODEL =&nbsp;TRAMONT ABOVE GRADE AST RECTANGULAR 600 GALONS WITH SERIAL NUMBER 89341103A</p>\n\n<p></p>\n\n<p><strong>ATS#4 U BUS GENERATOR TO UTILITY = ASCO 7000 SERIES; ATS#2 SERIAL NUMBER 1657015-002 WE; AMPS =3000; VOLTS = 400V 50-60HZ</strong></p>\n\n<p></p>\n\n<p><u><strong>GENSET # 3</strong></u></p>\n\n<p>MAKE AND MODEL = CAT 3456 / SR-4B; SERIAL AND SPEC NUMBER = CAT00000VCB01355;&nbsp;</p>\n\n<p></p>\n\n<p><strong><u>ATS CHANCERY GENERATOR ROOM</u></strong></p>\n\n<p>MAKE AND MODEL = ASCO 7000 SERIES;&nbsp;CHANCERY GENERATOR DAY TANK MAKE AND MODEL =&nbsp;TRAMONT ABOVE GRADE AST RECTANGULAR 300 GALONS WITH SERIAL NUMBER 116978</p>\n\n<p></p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Carpenter, Timothy R","role":"primary","email":"CarpenterTR1@state.gov","phone":"7712068323"},{"name":"MARAH FAMA","role":"secondary","email":"MarahF@state.gov","phone":"+224629000534"}],"place_of_performance":{"city":{"code":"CONAKRY","name":"CONAKRY"},"state":{"code":"GN-C","name":"Conakry"},"country":{"code":"GIN","name":"GUINEA"}},"office_address":{"zip":"20520","city":"WASHINGTON","state":"DC","country":"USA"},"naics_codes":["811310"],"award":null,"attachments":[{"resource_id":"50f966517dcb4a96a588a393551f6119","name":"19GV1025Q0003 - REQUEST FOR OFFERS -PMSC FOR STANDBY GENERATORS-FINAL DRAFT.docx","kind":"file","mime_type":".docx","size_bytes":217619,"posted_at":"2025-01-22T22:44:52.423Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/50f966517dcb4a96a588a393551f6119/download","mirrored":false},{"resource_id":"58c6346ae5714197b7782c7bba07fbf1","name":"19GV1025Q0003 - REQUEST FOR OFFERS -PMSC FOR STANDBY GENERATORS-FINAL DRAFT.pdf","kind":"file","mime_type":".pdf","size_bytes":708535,"posted_at":"2025-01-22T22:44:52.423Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/58c6346ae5714197b7782c7bba07fbf1/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_19GV1025F0262_1900_19GV1025D0001_1900","permalink":"https://www.usaspending.gov/award/CONT_AWD_19GV1025F0262_1900_19GV1025D0001_1900/","piid":"19GV1025F0262","parent_piid":"19GV1025D0001","award_type":"DELIVERY ORDER","vendor_key":"LN9PU5M2YZN5","recipient_name":"MISCELLANEOUS FOREIGN AWARDEES","recipient_uei":"LN9PU5M2YZN5","recipient_cage":"35KC0","recipient_city":"WASHINGTON","recipient_state":"DC","sub_name":"Department of State","office_name":"U.S. EMBASSY CONAKRY","office_key":"o-19GV10","first_action_date":"2025-08-28","last_action_date":"2026-04-10","actions":2,"obligated":"198.99","current_total_value":"198.99","potential_total_value":"198.99","naics":"335312","psc":"H349","extent_competed":"COMPETED UNDER SAP","set_aside":null,"offers_received":null,"description":"CKY-FMS-BASE YEAR PMSC FOR STANDBY LV GENERATORS","method":"solicitation","confidence":"high","evidence":["solicitation number 19GV1025Q0003 equals the FPDS solicitation identifier","same awarding office 19GV10"],"opportunity_key":null,"opportunity_title":null},{"award_key":"CONT_IDV_19GV1025D0001_1900","permalink":"https://www.usaspending.gov/award/CONT_IDV_19GV1025D0001_1900/","piid":"19GV1025D0001","parent_piid":null,"award_type":null,"vendor_key":"LN9PU5M2YZN5","recipient_name":"MISCELLANEOUS FOREIGN AWARDEES","recipient_uei":"LN9PU5M2YZN5","recipient_cage":"35KC0","recipient_city":"WASHINGTON","recipient_state":"DC","sub_name":"Department of State","office_name":"U.S. EMBASSY CONAKRY","office_key":"o-19GV10","first_action_date":"2025-07-29","last_action_date":"2025-07-29","actions":1,"obligated":"0","current_total_value":null,"potential_total_value":"101941.75","naics":"335312","psc":"H349","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":6,"description":"CKY-FAC 4000 M&R CMD DIESEL GENERATORS PMSC CONTRACT - AWARD","method":"solicitation","confidence":"high","evidence":["solicitation number 19GV1025Q0003 equals the FPDS solicitation identifier","same awarding office 19GV10"],"opportunity_key":null,"opportunity_title":null}],"related":[],"similar_open":[{"key":"M6740027Q0001","latest_notice_id":"c061b34909a84c19a5fc6ff52f366470","title":"Hydrostatic Testing","solicitation_number":"M6740027Q0001","notice_type":"o","first_type":"o","first_posted":"2026-11-05","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-29T23:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-29T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-M67400","office_name":"COMMANDING OFFICER","naics":"811310","psc":"H312","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"JPN","place_scope":"overseas","state_source":null,"state_evidence":"JAPAN","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"},{"key":"W51LL527QA003","latest_notice_id":"73068d991fa24e30a387c71a264d24de","title":"EURO-DIESEL DRUPS (DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY)","solicitation_number":"W51LL527QA003","notice_type":"o","first_type":"o","first_posted":"2026-10-30","last_posted":"2026-10-30","notices":1,"due_at":"2026-11-30T04:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T04:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W51LL5","office_name":"0906 AQ CO DET B CONTRACTI","naics":"811310","psc":"J061","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-31T03:50:03.904859Z"},{"key":"80NSSC27948630Q","latest_notice_id":"d4807b9415734ac0a22e33a085b44592","title":"Removal, refurbishment, and reinstallation of two (2) 200 HP General Electric (GE) induction motor at the Unitary Plan Wind Tunnel facility","solicitation_number":"80NSSC27948630Q","notice_type":"k","first_type":"k","first_posted":"2026-11-17","last_posted":"2026-11-24","notices":6,"due_at":"2026-12-01T21:00:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"811310","psc":"J059","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":58,"indexable":false}