{"canonical":"https://sealedbidder.com/opportunities/15bftd25q00000008","key":"15BFTD25Q00000008","url":"https://sealedbidder.com/opportunities/15bftd25q00000008","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2025-03-21T03:59:00Z","first_posted":"2025-02-27","last_posted":"2025-04-09","department":"JUSTICE, DEPARTMENT OF","subagency":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office":"FCI FORT DIX","naics":"238220","psc":"4540","set_aside":"SBA","place_state":"NJ","place_scope":"nationwide","site":"Fort Dix","place_state_source":null,"place_evidence":null,"place_county":"34005","place_county_name":"Burlington County","place_city":null,"place_city_name":null,"winner":"ANDERSON GENERAL BDS LLC","award_amount":null,"publications":[{"notice_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","base_type":"o","posted":"2025-02-27","posted_at":"2025-02-27T18:34:57.593Z","due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-04-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9e5ffdfb30014ab68c2fc336ffe4c41f/view","enriched":true,"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}]},{"notice_id":"4911ef3b08e742fdbff65d67a13d063d","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","base_type":"o","posted":"2025-02-28","posted_at":"2025-02-28T14:19:31.355Z","due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-04-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4911ef3b08e742fdbff65d67a13d063d/view","enriched":true,"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}]},{"notice_id":"f8ff7891cf2044bcbcba158dab9768e4","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","base_type":"o","posted":"2025-02-28","posted_at":"2025-02-28T19:53:16.472Z","due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-04-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f8ff7891cf2044bcbcba158dab9768e4/view","enriched":true,"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}]},{"notice_id":"100fce066b0d454f93bd22039ff31d13","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","base_type":"o","posted":"2025-03-04","posted_at":"2025-03-04T15:05:57.541Z","due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-04-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/100fce066b0d454f93bd22039ff31d13/view","enriched":true,"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}]},{"notice_id":"4d78b8f7d1434764be02c66b6b6e5f5c","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","base_type":"o","posted":"2025-03-14","posted_at":"2025-03-14T10:31:13.661Z","due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-04-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4d78b8f7d1434764be02c66b6b6e5f5c/view","enriched":true,"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}]},{"notice_id":"fcea037539204c2b95bef5994028b130","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","base_type":"o","posted":"2025-03-18","posted_at":"2025-03-18T11:44:13.741Z","due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-04-04","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/fcea037539204c2b95bef5994028b130/view","enriched":true,"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}]},{"notice_id":"d1e9de978043490da557bec898157c56","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","base_type":"o","posted":"2025-04-09","posted_at":"2025-04-09T14:20:21.445Z","due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-04-30","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d1e9de978043490da557bec898157c56/view","enriched":true,"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}]},{"notice_id":"d3d829047bbc4555bcd1407167347bb9","title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","solicitation_number":"15BFTD25Q00000008","notice_type":"o","base_type":"o","posted":"2025-04-09","posted_at":"2025-04-09T14:20:21.445Z","due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","cancelled":false,"archived":true,"archive_date":"2025-04-09","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d3d829047bbc4555bcd1407167347bb9/view","enriched":true,"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}]}],"latest_notice_id":"d3d829047bbc4555bcd1407167347bb9","first_type":"o","notices":[{"dates":{"posted":"2025-02-27","posted_at":"2025-02-27T18:34:57.593Z","created_at":"2025-02-27T18:23:15.837Z","modified_at":"2025-04-09T14:24:02.907Z","response_deadline":{"raw":"2025-03-20T23:59:00-04:00","utc":"2025-03-21T03:59:00Z","date":"2025-03-20","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9e5ffdfb30014ab68c2fc336ffe4c41f/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","agency":{"office":{"code":"15BFTD","name":"FCI FORT DIX"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"organization_id":"500025338","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-04","archive_type":"auto15"},"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}],"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T12:02:52.963135114Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"65377e1f543d4c84551d6930cac5008b54f6aedc0ad3a14cd216267bfe0b20cf","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T12:02:52.963135114Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15BFTD25Q00000008","place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4540"},{"dates":{"posted":"2025-02-28","posted_at":"2025-02-28T14:19:31.355Z","created_at":"2025-02-28T14:17:42.836Z","modified_at":"2025-04-09T14:24:02.907Z","response_deadline":{"raw":"2025-03-20T23:59:00-04:00","utc":"2025-03-21T03:59:00Z","date":"2025-03-20","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4911ef3b08e742fdbff65d67a13d063d/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","agency":{"office":{"code":"15BFTD","name":"FCI FORT DIX"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"organization_id":"500025338","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-04","archive_type":"auto15"},"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}],"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"4911ef3b08e742fdbff65d67a13d063d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T10:14:35.445256104Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"59da7b82ed619d727d30bed06d31fe272dad0dff2d3986b6218823aa783ae201","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T10:14:35.445256104Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15BFTD25Q00000008","place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4540"},{"dates":{"posted":"2025-02-28","posted_at":"2025-02-28T19:53:16.472Z","created_at":"2025-02-28T19:52:11.872Z","modified_at":"2025-04-09T14:24:02.907Z","response_deadline":{"raw":"2025-03-20T23:59:00-04:00","utc":"2025-03-21T03:59:00Z","date":"2025-03-20","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f8ff7891cf2044bcbcba158dab9768e4/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","agency":{"office":{"code":"15BFTD","name":"FCI FORT DIX"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"organization_id":"500025338","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-04","archive_type":"auto15"},"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}],"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"f8ff7891cf2044bcbcba158dab9768e4","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T11:03:04.971216830Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8dcd19f33a347deb50a2404f6deecb7dea1e18ec3eec2e9fd433678e421700cb","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T11:03:04.971216830Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15BFTD25Q00000008","place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4540"},{"dates":{"posted":"2025-03-04","posted_at":"2025-03-04T15:05:57.541Z","created_at":"2025-03-04T15:04:58.983Z","modified_at":"2025-04-09T14:24:02.907Z","response_deadline":{"raw":"2025-03-20T23:59:00-04:00","utc":"2025-03-21T03:59:00Z","date":"2025-03-20","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/100fce066b0d454f93bd22039ff31d13/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","agency":{"office":{"code":"15BFTD","name":"FCI FORT DIX"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"organization_id":"500025338","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-04","archive_type":"auto15"},"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}],"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"100fce066b0d454f93bd22039ff31d13","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-21T03:39:07.824411295Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4556c6a98d36e37e7a8571ddbd98be1acc3955d7f22396b36e24933bf252a507","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-21T03:39:07.824411295Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15BFTD25Q00000008","place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4540"},{"dates":{"posted":"2025-03-14","posted_at":"2025-03-14T10:31:13.661Z","created_at":"2025-03-14T10:30:25.350Z","modified_at":"2025-04-09T14:24:02.907Z","response_deadline":{"raw":"2025-03-20T23:59:00-04:00","utc":"2025-03-21T03:59:00Z","date":"2025-03-20","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4d78b8f7d1434764be02c66b6b6e5f5c/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","agency":{"office":{"code":"15BFTD","name":"FCI FORT DIX"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"organization_id":"500025338","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-04","archive_type":"auto15"},"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}],"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"4d78b8f7d1434764be02c66b6b6e5f5c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T09:20:00.797432794Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"4f86392b65ce475d48e0e38ff74f73583d708192dbd8c1dff1e38c8d092cb5da","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-20T09:20:00.797432794Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15BFTD25Q00000008","place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4540"},{"dates":{"posted":"2025-03-18","posted_at":"2025-03-18T11:44:13.741Z","created_at":"2025-03-18T11:43:13.740Z","modified_at":"2025-04-09T14:24:02.907Z","response_deadline":{"raw":"2025-03-20T23:59:00-04:00","utc":"2025-03-21T03:59:00Z","date":"2025-03-20","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/fcea037539204c2b95bef5994028b130/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","agency":{"office":{"code":"15BFTD","name":"FCI FORT DIX"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"organization_id":"500025338","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-04","archive_type":"auto15"},"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}],"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"fcea037539204c2b95bef5994028b130","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-20T03:33:38.696992953Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"3f2fb0b6edd8f4e0a7d3e29e329726a807176f9239cda389baf8ef353338cfd4","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-20T03:33:38.696992953Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15BFTD25Q00000008","place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4540"},{"dates":{"posted":"2025-04-09","posted_at":"2025-04-09T14:20:21.445Z","created_at":"2025-04-09T14:20:21.445Z","modified_at":"2025-04-09T14:24:02.907Z","response_deadline":{"raw":"2025-03-20T23:59:00-04:00","utc":"2025-03-21T03:59:00Z","date":"2025-03-20","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d1e9de978043490da557bec898157c56/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","agency":{"office":{"code":"15BFTD","name":"FCI FORT DIX"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"organization_id":"500025338","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-30","archive_type":"auto_custom"},"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}],"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"d1e9de978043490da557bec898157c56","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-18T03:59:36.020002623Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"a4be0f52515aa3296c9ad74a20380fa4a2957f79aa42f9bb5d26d99b02bc05ae","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-18T03:59:36.020002623Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15BFTD25Q00000008","place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4540"},{"dates":{"posted":"2025-04-09","posted_at":"2025-04-09T14:20:21.445Z","created_at":"2025-04-09T14:24:02.907Z","modified_at":"2025-04-09T14:24:02.907Z","response_deadline":{"raw":"2025-03-20T23:59:00-04:00","utc":"2025-03-21T03:59:00Z","date":"2025-03-20","time":"23:59:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d3d829047bbc4555bcd1407167347bb9/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","agency":{"office":{"code":"15BFTD","name":"FCI FORT DIX"},"subtier":{"code":"1540","name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS"},"department":{"code":"015","name":"JUSTICE, DEPARTMENT OF"},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"organization_id":"500025338","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2025-04-09","archive_type":"manual"},"history":[{"index":9,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d3d829047bbc4555bcd1407167347bb9","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":8,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-04-09T14:20:21.445Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"d1e9de978043490da557bec898157c56","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":7,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-18T11:44:13.741Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"fcea037539204c2b95bef5994028b130","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":5,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-14T10:31:13.661Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4d78b8f7d1434764be02c66b6b6e5f5c","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":4,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-03-04T15:05:57.541Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"100fce066b0d454f93bd22039ff31d13","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":3,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T19:53:16.472Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"f8ff7891cf2044bcbcba158dab9768e4","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":2,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-28T14:19:31.355Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"4911ef3b08e742fdbff65d67a13d063d","solicitation_number":"15BFTD25Q00000008","parent_opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f"},{"index":1,"title":"NEW, NEW, FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2025-02-27T18:34:57.593Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","solicitation_number":"15BFTD25Q00000008"}],"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"d3d829047bbc4555bcd1407167347bb9","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9e5ffdfb30014ab68c2fc336ffe4c41f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-18T04:00:12.050651446Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"249c1f39e41575e8a2ffa617fab03328553258a46bde167c6cc8fafe6552e127","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-11-18T04:00:12.050651446Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"15BFTD25Q00000008","place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4540"}],"due_at":"2025-03-21T03:59:00Z","due_date":"2025-03-20","closes_at":"2025-03-21T03:59:00Z","awardable":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1540","sub_name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office_key":"o-15BFTD","office_name":"FCI FORT DIX","state":"NJ","county":"34005","county_name":"Burlington County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":"fort-dix-nj","winner_key":"WDKDC8S8V2A5","amount":null,"linked_awards":8,"cancelled":false,"archived":true,"updated_at":"2026-11-18T04:24:25.478875Z","principal_notice_id":"d3d829047bbc4555bcd1407167347bb9","description":{"text":"FCI FORT DIX NJ\n\nSTATEMENT OF WORK\n\nUPGRADE HVAC 5845 SHU\n\nThe Federal Correctional Institution (FCI) located at Fort Dix,\n\nNew Jersey, intends to make a single award to a responsible\n\nentity for the removal and installation of a 30 - ton package\n\nrooftop heating and cooling system as set forth in this\n\nsolic itati on/contract.\n\nThe Government reserves the right to award without discussion\n\nand to make a single award . Therefore , each initial quoted\n\nshould contain the best terms from a cost or price standpoint.\n\nPLACE OF PERFORMANCE\n\nFCI Fort Dix\n\n5755 Hartford Road\n\nJoint Base MDL, New Jersey 08640\n\nWest Compound Building 5845 Rooftop\n\nSCHEDULE OF DELIVERY PERFORMANCE\n\nThe contractor wil l provide all labor , material and equipment\n\nnecessary to acquire , transport , and install a new 30 - ton\n\npackage rooftop heating and cooling system to the roof of\n\nBuilding 5845 . The contractor will be responsible for the\n\nremoval of the existing rooftop heating/cooling system . The\n\ncontractor must be licensed to perform work in the state of New\n\nJersey and must provide licensure and/or certification s .\n\nThe contractor must use a crane that is of capable s ize and\n\nreach to ensure safe removal of old and installation of new unit\n\nto the rooftop.\n\nThe contractor will provide a specification cut sheet of the\n\npackage rooftop unit to the COR for acceptance no later than\n\nfourteen (14) days after award.\n\nSCHEDULE OF PERFORMANCE\n\nNormal working hours are estimated Monday thru Friday 7 : 30AM-\n\n3 : 00PM to exclude federal holidays . Saturday and Sunday hours\n\nmay be utilized due to adverse weather conditions or other\n\ncontr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a\n\nforty (40) hour work week at the work site.\n\nThe new unit MUST be operational within twelve (12) hours after\n\nthe existing unit is removed from service and/or power\n\ndisconnected, whichever occurs first. The package unit provides\n\nheating and cooling to a secure environment that requires\n\nadequate airflow and/or heat and cooling temperatures.\n\nDESCRIPTION OF BUILDING 5845\n\nBuilding 5845 is a 3-story 36' tall mixed-use building. Building\n\n5845 is located behind several 12' high security fences with\n\nrazor wire. Building to the furthest fence/roadway is\n\napproximately 56'. Building roof is accessed through a hatch\n\n3'x3'. Vehicle access is restricted to the outside perimeter\n\nroadway. Contractor is permitted to use a crane to remove old\n\nand install new package rooftop units.\n\nDESCRIPTION OF HEATING/COOLING UNIT\n\nSpecification on the new unit must meet at a minimum the\n\nrequirements below:\n\n-30-ton package rooftop unit\n\n-R454B\n\n-Bottom Return, Bottom Supply Configuration\n\n-2 08 I 3/ 60\n\n-Constant volume forward curve class one 15HP ultra high\n\nefficiency supply fan\n\n-1\" deflection\n\n-Condenser coil seamless copper tubes\n\n-Hot gas bypass (Modulating hot gas reheat factory installed)\n\n-Standard evaporator coil\n\n-Zero-degree low ambient package (factory installed)\n\n-2\" pleated filters\n\n-Single enthalpy economizer\n\n-Controller with factory disconnect and convenience outlet\n\n-Stainless steel drain pan\n\n-Hinged Access cabinet panels\n\n-High/Low Refrigerant Pressure Protection\n\n-Field installed barometric relief damper for the horizontal\n\nreturn air duct\n\n-Unit shall be rated by the manufacturer at a minimum 11.1 EER\n\n-Unit will be fully charged with R454B refrigerant.\n\n-Unit shall carry both ETL and CGA safety approval ratings.\n\n-Tags and decals to aid in the service or indicate caution areas\n\nshall be provided.\n\n-Unit shall be capable of providing mechanical cooling down to\n\n40 degrees Fahrenheit.\n\n-Unit shall be capable of starting and running at 120 degrees\n\nFahrenheit.\n\n-Drive type- belt\n\n-Heating input capacity (max) 620 MBH\n\n-Heat exchanger of tubular design, stainless steel\n\n-Maintenance manuals will be supplied.\n\nThe contractor will install any new duct work/curb required to\n\ntie in the new unit to any existing duct work/curb.\n\nThe contractor must install a standalone electrical disconnect\n\nfor the new package rooftop unit. The exiting unit to be removed\n\nonly utilizes a built-in disconnect.\n\nREMOVAL OF EXISTING HVAC\n\nThe contractor shall remove the existing package rooftop\n\nheating/cooling system in conjunction with the installation of\n\nnew rooftop package unit. The existing unit will remain the\n\nproperty of FCI Fort Dix. The contractor will be responsible for\n\nrecovery and recycling of remaining refrigerant in accordance\n\nwith all federal, state, and local regulations.\n\nThe unit to be removed - York Model Z33AD52A7CDABE0001A S/N\n\nNOG9084213\n\nDELIVERY OF MATERIALS\n\nAll construction related equipment and materials required for\n\nthe contractor to work on this project will be processed by the\n\ncontractor and delivered to the contractors approved storage\n\narea. Any construction related deliveries which are delivered on\n\nsite, can be received by the contractor Monday through Friday,\n\nexcluding Federal Holidays between the hours of 7:00AM - 3;00PM.\n\nThe contractor will be required to notify the COR when a\n\ndelivery is scheduled, and a contractor representative must be\n\npresent at time of delivery.\n\nFINAL INSPECTION AND TESTING\n\nThe contractor at a minimum shall meet manufacturer\n\nrecommendations, and industry standards set forth in accordance\n\nwith all federal, state, and local regulations. Upon the\n\ncompletion of the installation, the contractor will inspect and\n\nverify all work is completed to the satisfaction of the Contract\n\nOfficer Representative (COR). The contractor shall perform\n\noperational testing, break-in testing, and adjustments to the\n\nsatisfaction of the COR. The contractor shall warrant its\n\nproducts and labor procured and installed to be free of defects\n\nin materials and workmanship for a minimum period from the date\n\nthe system is accepted by the COR as described below:\n\n• Minimum twelve (12) month standard warranty for the 30-ton\n\npackage rooftop unit on parts and labor.\n\n• Minimum five (5) year warranty on the compressor.\n\n• Minimum fifteen (15) year warranty on the stainless steel\n\nheat exchanger.\n\n• Contractor will clearly indis;ate a start period and end\n\nperiod in writing for the warranty in the following format:\n\nmonth/day/year.\n\nThis warranty is in addition to any manufacturer warranties\n\nprovided with the unit.\n\nUpon completion of the installation, testing, and acceptance,\n\nthe contractor shall provide the COR a hardcopy and/or a PDF\n\nversion maintenance manuals and software manuals.\n\nSTORAGE OF TOOLS, MATERIALS, AND EQUIPMENT\n\n\\\n\nAny contractor materials, tools, and/or equipment that will be\n\nrequired to be brought on site for an extended period to\n\nexpedite the project completion shall be permitted to be stored\n\nin a previously approved location agreed upon by the Contract\n\nOfficer Representative (COR) and the contractor.\n\nAny tool considered a high security risk will be required to\n\nexit the institution grounds daily.\n\nCONSTRUCTION PROGRESS MEETINGS\n\nThe Contract Officer Representative or Facility Manager reserve\n\nthe right to require weekly or bi-weekly progress meetings with\n\nthe contractor(s) project manager to ensure sch?duling\n\nrequirements are met in accordance with this contract. Meetings\n\nshall include but not limited to pre-construction meeting(s)\n\nprogress meeting(s), meeting agenda, minutes, and construction\n\nschedule.\n\nDEFINITIONS\n\nThe Contract Officer (CO) executes the contract on behalf of the\n\nGovernment; this shall include a duly appointed successor. The\n\nContracting Officer is the only official authorized to\n\nadminister, modify and/or terminate the contract. The\n\nContracting Officer makes related approvals, determinations, and\n\nfinding pertaining to the contract and is the only individual on\n\nthe project staff who can obligate funds on behalf of the\n\nGovernment.\n\nThe FCI shall ensure a Contract Officer's Representative ~COR)\n\nis present to allow access to all areas by the contractor. The\n\nCOR will be located at the project site and has overall\n\nresponsibility for the administration of the operations and\n\nactivit{es at the project site. The COR represents the Contract\n\nOfficer for all technical matters that arise under the contract.\n\nThe COR will evaluate the contractor's performance and prepare a\n\nperformance report at the end of the contract.\n\nThe Contract Officer Representative (COR) shall not and has no\n\nauthority to re-delegate authority to any other person, change\n\nor modify any terms of the contract, obligate the payment of any\n\nmoney by the Government and/or cause the contractor to incur\n\ncost not otherwise covered by the contract.\n\nThe contractor shall provide to the Contract Officer, (3) three\n\ncopies of the safety data sheet (SDS) on all materials and\n\nsubstances that may be used during the project. In the event the\n\nInstitution Safety Manager does not approve the material, it\n\nshall be the responsibility of the Contractor to locate and\n\nprocure an alternative product.\n\nOTHER CONSIDERATION\n\nLost time due to security restrictions/considerations:\n\ncontractors should plan for a certain amount of time accrued for\n\nsecurity considerations, i.e., base security checkpoint, check\n\nin screening, delays due to inmate movements, institution\n\nlockdowns, institution emergencies, institution counts etc. In\n\nthe event of an institutional emergency, the Contractor will be\n\ninstructed to secure and stow all tools, equipment and\n\nmaterials, and contractor will be escorted off the institution\n\ngrounds. Work will be suspended until the institution emergency\n\npasses. The work location is considered inside the confines of\n\nthe secure institution. The institution reserves the right to\n\nsuspend work for any reason listed above.\n\nXCContractor will NOT be allowed to bring weapons, cell phones or\n\nany other objects that violate criminal laws or are prohibited\n\nby Federal regulations or Bureau of Prisons policies on\n\ninstitution grounds. The Contractor shall be responsible for\n\nremoving all waste from the institution grounds and disposing of\n\nin accordance with all federal, state, and local regulations.\n\nINSTITUTION SECURTIY\n\nThe Contractor agrees to adhere to all regulations as outlined\n\nin HSPD-12 (Homeland Security Presidential Directive), agrees to\n\nadhere to all regulations prescribed by the institution for\n\nsafety, custody and conduct of staff, contractor workers and\n\ninmates. The contractor will be required to complete a limited\n\nbackg:round investigation through the National Crime Information\n\nCenter (NCIC). The Contractor may at any time be removed from\n\nthe institution grounds at the discretion of the Warden.\n\nPAYMENT TERMS\n\nThe Contractor must provide a means for electronic payment to\n\ninclude bank routing and account number, payment terms are\n\nspecified in FAR 52.212-4(g). The Government will make payment\n\nin accordance with the Prompt Payment Act (31 U.S.C 3903 and\n\nprompt payment regulations at 5 CFR part 1315). The Contractor·\n\ncan however offer discount payment terms for prompt payments as\n\nspecified in block 12 on the SF 1449 form of this solicitation.\n\nPartial or half sessions will not be authorized for payment.\n\n__________________________________________________________________________________\n\nFCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nSEE ATTACHMENTS\n\nThe Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.\n\nTHE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE & SMALL BUSISNESS SET- ASIDE.\n\nMUST SEE: ATTACHMENTS - STATEMENT OF WORK & OTHER DOCUMENTS.\n\n1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.\n\n2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.\n\n3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.\n\n4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV\n\n5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.\n\nTHE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV ( CONTRACT SPECIALIST)","html":"<p><strong>FCI FORT DIX NJ</strong><br />\n<strong>STATEMENT OF WORK</strong><br />\n<strong>UPGRADE HVAC 5845 SHU</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p></p>\n\n<p><strong>The Federal Correctional Institution (FCI) located at Fort Dix,</strong><br />\n<strong>New Jersey, intends to make a single award to a responsible</strong><br />\n<strong>entity for the removal and installation of a 30 - ton package</strong><br />\n<strong>rooftop heating and cooling system as set forth in this</strong><br />\n<strong>solic itati on/contract.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The Government reserves the right to award without discussion</strong><br />\n<strong>and to make a single award . Therefore , each initial quoted</strong><br />\n<strong>should contain the best terms from a cost or price standpoint.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PLACE OF PERFORMANCE</strong><br />\n<strong>FCI Fort Dix</strong><br />\n<strong>5755 Hartford Road</strong><br />\n<strong>Joint Base MDL, New Jersey 08640</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>West Compound Building 5845 Rooftop</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF DELIVERY PERFORMANCE</strong><br />\n<strong>The contractor wil l provide all labor , material and equipment</strong><br />\n<strong>necessary to acquire , transport , and install a new 30 - ton</strong><br />\n<strong>package rooftop heating and cooling system to the roof of</strong><br />\n<strong>Building 5845 . The contractor will be responsible for the</strong><br />\n<strong>removal of the existing rooftop heating/cooling system . The</strong><br />\n<strong>contractor must be licensed to perform work in the state of New</strong><br />\n<strong>Jersey and must provide licensure and/or certification s .</strong><br />\n<strong>The contractor must use a crane that is of capable s ize and</strong><br />\n<strong>reach to ensure safe removal of old and installation of new unit</strong><br />\n<strong>to the rooftop.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>The contractor will provide a specification cut sheet of the</strong><br />\n<strong>package rooftop unit to the COR for acceptance no later than</strong><br />\n<strong>fourteen (14) days after award.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>SCHEDULE OF PERFORMANCE</strong><br />\n<strong>Normal working hours are estimated Monday thru Friday 7 : 30AM-</strong><br />\n<strong>3 : 00PM to exclude federal holidays . Saturday and Sunday hours</strong><br />\n<strong>may be utilized due to adverse weather conditions or other</strong><br />\n<strong>contr ibuting factors that would cause delay if approved by the COR and the contractor. The contractor cannot be guaranteed a</strong><br />\n<strong>forty (40) hour work week at the work site.</strong><br />\n<strong>The new unit MUST be operational within twelve (12) hours after</strong><br />\n<strong>the existing unit is removed from service and/or power</strong><br />\n<strong>disconnected, whichever occurs first. The package unit provides</strong><br />\n<strong>heating and cooling to a secure environment that requires</strong><br />\n<strong>adequate airflow and/or heat and cooling temperatures.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF BUILDING 5845</strong><br />\n<strong>Building 5845 is a 3-story 36&#39; tall mixed-use building. Building</strong><br />\n<strong>5845 is located behind several 12&#39; high security fences with</strong><br />\n<strong>razor wire. Building to the furthest fence/roadway is</strong><br />\n<strong>approximately 56&#39;. Building roof is accessed through a hatch</strong><br />\n<strong>3&#39;x3&#39;. Vehicle access is restricted to the outside perimeter</strong><br />\n<strong>roadway. Contractor is permitted to use a crane to remove old</strong><br />\n<strong>and install new package rooftop units.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DESCRIPTION OF HEATING/COOLING UNIT</strong><br />\n<strong>Specification on the new unit must meet at a minimum the</strong><br />\n<strong>requirements below:</strong><br />\n<strong>-30-ton package rooftop unit</strong><br />\n<strong>-R454B</strong><br />\n<strong>-Bottom Return, Bottom Supply Configuration</strong><br />\n<strong>-2 08 I 3/ 60</strong><br />\n<strong>-Constant volume forward curve class one 15HP ultra high</strong><br />\n<strong>efficiency supply fan</strong><br />\n<strong>-1&quot; deflection</strong><br />\n<strong>-Condenser coil seamless copper tubes</strong><br />\n<strong>-Hot gas bypass (Modulating hot gas reheat factory installed)</strong><br />\n<strong>-Standard evaporator coil</strong><br />\n<strong>-Zero-degree low ambient package (factory installed)</strong><br />\n<strong>-2&quot; pleated filters</strong><br />\n<strong>-Single enthalpy economizer</strong><br />\n<strong>-Controller with factory disconnect and convenience outlet</strong><br />\n<strong>-Stainless steel drain pan</strong><br />\n<strong>-Hinged Access cabinet panels</strong></p>\n\n<p><strong>-High/Low Refrigerant Pressure Protection</strong><br />\n<strong>-Field installed barometric relief damper for the horizontal</strong><br />\n<strong>return air duct</strong><br />\n<strong>-Unit shall be rated by the manufacturer at a minimum 11.1 EER</strong><br />\n<strong>-Unit will be fully charged with R454B refrigerant.</strong><br />\n<strong>-Unit shall carry both ETL and CGA safety approval ratings.</strong><br />\n<strong>-Tags and decals to aid in the service or indicate caution areas</strong><br />\n<strong>shall be provided.</strong></p>\n\n<p><strong>-Unit shall be capable of providing mechanical cooling down to</strong><br />\n<strong>40 degrees Fahrenheit.</strong><br />\n<strong>-Unit shall be capable of starting and running at 120 degrees</strong><br />\n<strong>Fahrenheit.</strong><br />\n<strong>-Drive type- belt</strong><br />\n<strong>-Heating input capacity (max) 620 MBH</strong><br />\n<strong>-Heat exchanger of tubular design, stainless steel</strong><br />\n<strong>-Maintenance manuals will be supplied.</strong><br />\n<strong>The contractor will install any new duct work/curb required to</strong><br />\n<strong>tie in the new unit to any existing duct work/curb.</strong><br />\n<strong>The contractor must install a standalone electrical disconnect</strong><br />\n<strong>for the new package rooftop unit. The exiting unit to be removed</strong><br />\n<strong>only utilizes a built-in disconnect.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>REMOVAL OF EXISTING HVAC</strong><br />\n<strong>The contractor shall remove the existing package rooftop</strong><br />\n<strong>heating/cooling system in conjunction with the installation of</strong><br />\n<strong>new rooftop package unit. The existing unit will remain the</strong><br />\n<strong>property of FCI Fort Dix. The contractor will be responsible for</strong><br />\n<strong>recovery and recycling of remaining refrigerant in accordance</strong><br />\n<strong>with all federal, state, and local regulations.</strong><br />\n<strong>The unit to be removed - York Model Z33AD52A7CDABE0001A S/N</strong><br />\n<strong>NOG9084213</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>DELIVERY OF MATERIALS</strong><br />\n<strong>All construction related equipment and materials required for</strong><br />\n<strong>the contractor to work on this project will be processed by the</strong><br />\n<strong>contractor and delivered to the contractors approved storage</strong><br />\n<strong>area. Any construction related deliveries which are delivered on</strong><br />\n<strong>site, can be received by the contractor Monday through Friday,</strong><br />\n<strong>excluding Federal Holidays between the hours of 7:00AM - 3;00PM.</strong><br />\n<strong>The contractor will be required to notify the COR when a</strong><br />\n<strong>delivery is scheduled, and a contractor representative must be</strong><br />\n<strong>present at time of delivery.</strong></p>\n\n<p></p>\n\n<p><strong>FINAL INSPECTION AND TESTING</strong><br />\n<strong>The contractor at a minimum shall meet manufacturer</strong><br />\n<strong>recommendations, and industry standards set forth in accordance</strong><br />\n<strong>with all federal, state, and local regulations. Upon the</strong><br />\n<strong>completion of the installation, the contractor will inspect and</strong><br />\n<strong>verify all work is completed to the satisfaction of the Contract</strong><br />\n<strong>Officer Representative (COR). The contractor shall perform</strong><br />\n<strong>operational testing, break-in testing, and adjustments to the</strong><br />\n<strong>satisfaction of the COR. The contractor shall warrant its</strong><br />\n<strong>products and labor procured and installed to be free of defects</strong><br />\n<strong>in materials and workmanship for a minimum period from the date</strong><br />\n<strong>the system is accepted by the COR as described below:</strong><br />\n<strong>&bull; Minimum twelve (12) month standard warranty for the 30-ton</strong><br />\n<strong>package rooftop unit on parts and labor.</strong><br />\n<strong>&bull; Minimum five (5) year warranty on the compressor.</strong><br />\n<strong>&bull; Minimum fifteen (15) year warranty on the stainless steel</strong><br />\n<strong>heat exchanger.</strong><br />\n<strong>&bull; Contractor will clearly indis;ate a start period and end</strong><br />\n<strong>period in writing for the warranty in the following format:</strong><br />\n<strong>month/day/year.</strong></p>\n\n<p><strong>This warranty is in addition to any manufacturer warranties</strong><br />\n<strong>provided with the unit.</strong><br />\n<strong>Upon completion of the installation, testing, and acceptance,</strong><br />\n<strong>the contractor shall provide the COR a hardcopy and/or a PDF</strong><br />\n<strong>version maintenance manuals and software manuals.</strong><br />\n<strong>STORAGE OF TOOLS, MATERIALS, AND EQUIPMENT</strong><br />\n<strong>\\</strong><br />\n<strong>Any contractor materials, tools, and/or equipment that will be</strong><br />\n<strong>required to be brought on site for an extended period to</strong><br />\n<strong>expedite the project completion shall be permitted to be stored</strong><br />\n<strong>in a previously approved location agreed upon by the Contract</strong><br />\n<strong>Officer Representative (COR) and the contractor.</strong><br />\n<strong>Any tool considered a high security risk will be required to</strong><br />\n<strong>exit the institution grounds daily.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>CONSTRUCTION PROGRESS MEETINGS</strong><br />\n<strong>The Contract Officer Representative or Facility Manager reserve</strong><br />\n<strong>the right to require weekly or bi-weekly progress meetings with</strong><br />\n<strong>the contractor(s) project manager to ensure sch?duling</strong><br />\n<strong>requirements are met in accordance with this contract. Meetings</strong><br />\n<strong>shall include but not limited to pre-construction meeting(s)</strong><br />\n<strong>progress meeting(s), meeting agenda, minutes, and construction</strong><br />\n<strong>schedule.</strong></p>\n\n<p></p>\n\n<p><strong>DEFINITIONS</strong><br />\n<strong>The Contract Officer (CO) executes the contract on behalf of the</strong><br />\n<strong>Government; this shall include a duly appointed successor. The</strong></p>\n\n<p><strong>Contracting Officer is the only official authorized to</strong><br />\n<strong>administer, modify and/or terminate the contract. The</strong><br />\n<strong>Contracting Officer makes related approvals, determinations, and</strong><br />\n<strong>finding pertaining to the contract and is the only individual on</strong><br />\n<strong>the project staff who can obligate funds on behalf of the</strong><br />\n<strong>Government.</strong><br />\n<strong>The FCI shall ensure a Contract Officer&#39;s Representative ~COR)</strong><br />\n<strong>is present to allow access to all areas by the contractor. The</strong><br />\n<strong>COR will be located at the project site and has overall</strong><br />\n<strong>responsibility for the administration of the operations and</strong><br />\n<strong>activit{es at the project site. The COR represents the Contract</strong><br />\n<strong>Officer for all technical matters that arise under the contract.</strong><br />\n<strong>The COR will evaluate the contractor&#39;s performance and prepare a</strong><br />\n<strong>performance report at the end of the contract.</strong><br />\n<strong>The Contract Officer Representative (COR) shall not and has no</strong><br />\n<strong>authority to re-delegate authority to any other person, change</strong><br />\n<strong>or modify any terms of the contract, obligate the payment of any</strong><br />\n<strong>money by the Government and/or cause the contractor to incur</strong><br />\n<strong>cost not otherwise covered by the contract.</strong><br />\n<strong>The contractor shall provide to the Contract Officer, (3) three</strong><br />\n<strong>copies of the safety data sheet (SDS) on all materials and</strong><br />\n<strong>substances that may be used during the project. In the event the</strong><br />\n<strong>Institution Safety Manager does not approve the material, it</strong><br />\n<strong>shall be the responsibility of the Contractor to locate and</strong><br />\n<strong>procure an alternative product.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>OTHER CONSIDERATION</strong><br />\n<strong>Lost time due to security restrictions/considerations:</strong><br />\n<strong>contractors should plan for a certain amount of time accrued for</strong><br />\n<strong>security considerations, i.e., base security checkpoint, check</strong><br />\n<strong>in screening, delays due to inmate movements, institution</strong><br />\n<strong>lockdowns, institution emergencies, institution counts etc. In</strong><br />\n<strong>the event of an institutional emergency, the Contractor will be</strong><br />\n<strong>instructed to secure and stow all tools, equipment and</strong><br />\n<strong>materials, and contractor will be escorted off the institution</strong><br />\n<strong>grounds. Work will be suspended until the institution emergency</strong><br />\n<strong>passes. The work location is considered inside the confines of</strong><br />\n<strong>the secure institution. The institution reserves the right to</strong><br />\n<strong>suspend work for any reason listed above.</strong></p>\n\n<p><strong>XCContractor will NOT be allowed to bring weapons, cell phones or</strong><br />\n<strong>any other objects that violate criminal laws or are prohibited</strong><br />\n<strong>by Federal regulations or Bureau of Prisons policies on</strong></p>\n\n<p><strong>institution grounds. The Contractor shall be responsible for</strong><br />\n<strong>removing all waste from the institution grounds and disposing of</strong><br />\n<strong>in accordance with all federal, state, and local regulations.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>INSTITUTION SECURTIY</strong><br />\n<strong>The Contractor agrees to adhere to all regulations as outlined</strong><br />\n<strong>in HSPD-12 (Homeland Security Presidential Directive), agrees to</strong><br />\n<strong>adhere to all regulations prescribed by the institution for</strong><br />\n<strong>safety, custody and conduct of staff, contractor workers and</strong><br />\n<strong>inmates. The contractor will be required to complete a limited</strong><br />\n<strong>backg:round investigation through the National Crime Information</strong><br />\n<strong>Center (NCIC). The Contractor may at any time be removed from</strong><br />\n<strong>the institution grounds at the discretion of the Warden.</strong><br />\n&nbsp;</p>\n\n<p></p>\n\n<p><strong>PAYMENT TERMS</strong><br />\n<strong>The Contractor must provide a means for electronic payment to</strong><br />\n<strong>include bank routing and account number, payment terms are</strong><br />\n<strong>specified in FAR 52.212-4(g). The Government will make payment</strong><br />\n<strong>in accordance with the Prompt Payment Act (31 U.S.C 3903 and</strong><br />\n<strong>prompt payment regulations at 5 CFR part 1315). The Contractor&middot;</strong><br />\n<strong>can however offer discount payment terms for prompt payments as</strong><br />\n<strong>specified in block 12 on the SF 1449 form of this solicitation.</strong><br />\n<strong>Partial or half sessions will not be authorized for payment.</strong></p>\n\n<p>__________________________________________________________________________________</p>\n\n<p></p>\n\n<p></p>\n\n<p>FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>SEE ATTACHMENTS</p>\n\n<p></p>\n\n<p>The Federal Correctional Institution (FCI) located at Fort Dix, New Jersey, intends to make a single award for FCI FORT DIX PURCHASE, INSTALLATION &amp; REMOVAL - OF HVAC ( heating and cooling system) ROOFTOP BUILDING -5845.</p>\n\n<p></p>\n\n<p>THE SOURCE SELECTION PROCESS WILL BE TO THE LOWEST PRICE TECHNICALLY ACCEPTABLE &amp; SMALL BUSISNESS SET- ASIDE.</p>\n\n<p></p>\n\n<p>MUST SEE: ATTACHMENTS - STATEMENT OF WORK &amp; OTHER DOCUMENTS.</p>\n\n<p></p>\n\n<p>1) SITE VISIT THURSDAY MARCH 13 2025 @ 9:00AM.</p>\n\n<p></p>\n\n<p>2) DEADLINE TO SUBMIT NCIC WEDNESDAY MARCH 5, 2025 11:59PM.- MUST BE SEND BY EMAIL ONLY TO TO MR. ROSS AT D1ROSS@BOP.GOV.</p>\n\n<p></p>\n\n<p>3) QUESTIONS SUBMISSION DEADLINE MONDAY MARCH 17, 2025 BY 12:00PM -MUST BE send to Mr. Ross , D1ROSS@BOP.GOV and cc TO Mr. Aponte, aaponteberrios@bop.gov.</p>\n\n<p></p>\n\n<p>4) QUESTIONS ANSWERED AND POSTED TO SAMS WEDNESDAY MARCH 19 2025) BID DUE MARCH 20, 2025 AT 11:59 PM, ET. THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV</p>\n\n<p></p>\n\n<p>5) BID DUE MARCH 20, 2025 AT 11:59 PM, ET.</p>\n\n<p>THE QUOTE OR BID MUST BE SENT TO ME ONLY; AAPONTEBERRIOS@BOP.GOV&nbsp; &nbsp;( CONTRACT SPECIALIST)</p>","origin":"detail"},"contacts":[{"name":"ARTURO APONTE BERRIOS","role":"primary","email":"AAPONTEBERRIOS@BOP.GOV","phone":"60972311005162"},{"name":"DAVID ROSS","role":"secondary","email":"D1ROSS@BOP.GOV","phone":"60972311006662"}],"place_of_performance":{"zip":"08641","city":{"code":"0","name":"Joint Base MDL"},"state":{"code":"NJ","name":"New Jersey"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"08640","city":"FORT DIX","state":"NJ","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"3bd65a043fda4b7882e08deded27767d","name":"SOLICITATION 1449 SHU ROOFTOP.pdf","kind":"file","mime_type":".pdf","size_bytes":312435,"posted_at":"2025-02-27T18:34:57.593Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3bd65a043fda4b7882e08deded27767d/download","mirrored":false},{"resource_id":"85e989b12bca48979fd6c47058fb3cf5","name":"NCIC FORM (New).pdf","kind":"file","mime_type":".pdf","size_bytes":626290,"posted_at":"2025-02-27T18:34:57.593Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/85e989b12bca48979fd6c47058fb3cf5/download","mirrored":false},{"resource_id":"dd6ed539aaa14b198ef9c3253d19beb8","name":"6_FTD_25Z2AB3_20241106_SOW_R1.pdf","kind":"file","mime_type":".pdf","size_bytes":112955,"posted_at":"2025-02-27T18:34:57.593Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/dd6ed539aaa14b198ef9c3253d19beb8/download","mirrored":false},{"resource_id":"821adcd1804a4bf6a8be7b490f8d8bbe","name":"SOLICITATION 1449 SHU ROOFTOP_1.pdf","kind":"file","mime_type":".pdf","size_bytes":334381,"posted_at":"2025-02-28T14:19:31.355Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/821adcd1804a4bf6a8be7b490f8d8bbe/download","mirrored":false},{"resource_id":"93d0b67deeda41d3b0840f5d7037cc23","name":"WAGE DETERMINATION_BURLINGTON_COUNTY_BACON-ACT.pdf","kind":"file","mime_type":".pdf","size_bytes":43543,"posted_at":"2025-02-28T19:53:16.472Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/93d0b67deeda41d3b0840f5d7037cc23/download","mirrored":false},{"resource_id":"f5e754e94587473dba3db433e6a4a63b","name":"WAGE DETERMINATION_BURLINGTON_COUNTY_SERVICES_CONTRACT-ACT.pdf","kind":"file","mime_type":".pdf","size_bytes":49454,"posted_at":"2025-02-28T19:53:16.472Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/f5e754e94587473dba3db433e6a4a63b/download","mirrored":false},{"resource_id":"b94c54d1ca514facb9bf20c7ef6e4a7f","name":"AT THE TIME TO RELEASE.docx","kind":"file","mime_type":".docx","size_bytes":14540,"posted_at":"2025-03-04T15:05:57.541Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b94c54d1ca514facb9bf20c7ef6e4a7f/download","mirrored":false},{"resource_id":"cc775d448ccf458e955cfc01ea4d18c4","name":"SITE_VISIT_MARCH_13_2025_NEW_HVAC.pdf","kind":"file","mime_type":".pdf","size_bytes":300798,"posted_at":"2025-03-14T10:31:13.661Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/cc775d448ccf458e955cfc01ea4d18c4/download","mirrored":false},{"resource_id":"2fa0d30f77b943b4b04878cb6a88cf58","name":"Pre-Bid Pictures.pdf","kind":"file","mime_type":".pdf","size_bytes":408749,"posted_at":"2025-03-18T11:44:13.741Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/2fa0d30f77b943b4b04878cb6a88cf58/download","mirrored":false},{"resource_id":"31dfcbd50bd047bcbb9e6bc7bcce2e8b","name":"PreBid Questions.pdf","kind":"file","mime_type":".pdf","size_bytes":101852,"posted_at":"2025-03-18T11:44:13.741Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/31dfcbd50bd047bcbb9e6bc7bcce2e8b/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_15BFTD25P00000137_1540_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_15BFTD25P00000137_1540_-NONE-_-NONE-/","piid":"15BFTD25P00000137","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"WDKDC8S8V2A5","recipient_name":"ANDERSON GENERAL BDS LLC","recipient_uei":"WDKDC8S8V2A5","recipient_cage":"9RYF2","recipient_city":"SYOSSET","recipient_state":"NY","sub_name":"Federal Prison System / Bureau of Prisons","office_name":"FCI FORT DIX","office_key":"o-15BFTD","first_action_date":"2025-03-21","last_action_date":"2025-06-03","actions":2,"obligated":"0","current_total_value":"0","potential_total_value":"0","naics":"238220","psc":"4520","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":21,"description":"FCI FORT DIX PURCHASE, INSTALLATION & REMOVAL - OF HVAC ( HEATING AND COOLING SYSTEM) ROOFTOP BUILDING -5845.","method":"solicitation","confidence":"high","evidence":["solicitation number 15BFTD25Q00000008 equals the FPDS solicitation identifier","same awarding office 15BFTD"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"15BFTD27Q00000001","latest_notice_id":"14f57bb805964ba2b38179f19e71c881","title":"(updated) 11/4/2027 FCI FORT DIX FY27 2nd QTR SUBSISTENCE; INCLUDING EGGS, BREAD AND DAIRY- JANUARY 1 2027- MARCH 31, 2027.","solicitation_number":"15BFTD27Q00000001","notice_type":"o","first_type":"o","first_posted":"2026-11-03","last_posted":"2026-11-04","notices":3,"due_at":"2027-11-16T04:59:00Z","due_date":"2027-11-15","closes_at":"2027-11-16T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1540","sub_name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office_key":"o-15BFTD","office_name":"FCI FORT DIX","naics":"311999","psc":"8945","set_aside":"SBA","state":"NJ","county":"34005","county_name":"Burlington County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Fort Dix","site_key":"fort-dix-nj","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"15BFTD27Q00000002","latest_notice_id":"f541bb271ed34231a47121481b6c0cb3","title":"updated (11/4/2027) FCI FORT DIX FY27 1ST QTR KOSHER - JANUARY 1 2027- MARCH 31, 2027.","solicitation_number":"15BFTD27Q00000002","notice_type":"o","first_type":"o","first_posted":"2026-11-03","last_posted":"2026-11-04","notices":2,"due_at":"2027-11-16T04:59:00Z","due_date":"2027-11-15","closes_at":"2027-11-16T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1540","sub_name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office_key":"o-15BFTD","office_name":"FCI FORT DIX","naics":"311999","psc":"8945","set_aside":"SBA","state":"NJ","county":"34005","county_name":"Burlington County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Fort Dix","site_key":"fort-dix-nj","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"},{"key":"15BFTD27Q00000003","latest_notice_id":"8df17b1cdd734ab2b2e3ff92e3009728","title":"UPDATED ( 11/4/2027) FCI FORT DIX FY27 1ST QTR HALAL - JANUARY 1 2027- MARCH 31, 2027.","solicitation_number":"15BFTD27Q00000003","notice_type":"o","first_type":"o","first_posted":"2026-11-03","last_posted":"2026-11-04","notices":2,"due_at":"2027-11-16T04:59:00Z","due_date":"2027-11-15","closes_at":"2027-11-16T04:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-015","dept_name":"JUSTICE, DEPARTMENT OF","sub_key":"s-1540","sub_name":"FEDERAL PRISON SYSTEM / BUREAU OF PRISONS","office_key":"o-15BFTD","office_name":"FCI FORT DIX","naics":"311999","psc":"8945","set_aside":"SBA","state":"NJ","county":"34005","county_name":"Burlington County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":"Fort Dix","site_key":"fort-dix-nj","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-05T04:36:35.392694Z"}],"similar_open":[{"key":"36C24226R0127","latest_notice_id":"2af01fdbb5af425da3127ce79f3a1d61","title":"Y1DA--561-24-600 Upgrade Mechanical Systems-C Level","solicitation_number":"36C24226R0127","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2027-01-04T15:00:00Z","due_date":"2027-01-04","closes_at":"2027-01-04T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"238220","psc":"Y1DA","set_aside":"SDVOSBC","state":"NJ","county":"34013","county_name":"Essex County","city":"3419390","city_name":"East Orange","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"W911PT27QA020","latest_notice_id":"084d5efc5ec44a9885a37b90e6705ffa","title":"REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS","solicitation_number":"W911PT27QA020","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"238220","psc":"Z2NB","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"IGH VELOCITY AIR HANDLING UNITSPROJECT LOCATION: WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"2031ZA27B00001","latest_notice_id":"622efd27a6cf48589063c08d3700b96b","title":"Modernize Regenerative Thermal Oxidizer (RTO)","solicitation_number":"2031ZA27B00001","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-020","dept_name":"TREASURY, DEPARTMENT OF THE","sub_key":"s-2041","sub_name":"BUREAU OF ENGRAVING AND PRINTING","office_key":"o-2031ZA","office_name":"OFFICE OF THE CHIEF PROCUREMENT OFFICER","naics":"238220","psc":"Z2AZ","set_aside":null,"state":"TX","county":"48439","county_name":"Tarrant County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"}],"similar_open_total":59,"indexable":false}