Justification

FY24 Emergency Replace Condensers FS Warehouse MOD 00001

15B21824P00000071-P00001

Federal Prison System / Bureau of Prisons, Fci Berlin. Plumbing, Heating, and Air-Conditioning Contractors.

Status

Justification

Posted December 19, 2024. Scheduled to archive January 18, 2025.

Get the next one like this from Federal Prison System / Bureau of Prisons by email, the day it is posted.Find my opportunities

This one is not taking offers

59 like it are open now in plumbing, heating, and air-conditioning contractors

All 59 open in plumbing, heating, and air-conditioning contractors

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Justification. Why an agency limited competition or awarded without it, citing the FAR authority. Glossary

Description

As published on SAM.gov.

FY24 Emergency Replace Condensers FS Warehouse MOD 00001 Recover refrigerant, disconnect piping, move equipment with customer forklift, set new equipment, connect to existing piping, install new suction line accumulator outside new unit, pressure test, evacuate lines, charge with new refrigerant, start and test. Isolated compressor and pressure tested with customer supplied nitrogen. Traced to leak at base of compressor bolt. Attempted to tighten to repair. Found unsuccessful.

Determined compressor would need to be removed for repair or possibly sent out for rebuild. Unit is 15 years old, added customer supplied POE to prevent oil failure, reset from tripping. Released nitrogen charge and completed evacuation test. Restored power, unit is operational but continuously loosing oil. Customer requests replacement unit.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. December 19, 2024

    Justification

    SAM.gov, notice b04da90a86234909ba3d54a76a1a9d63