Sources sought
FCC Hazelton, Fire Suppressions System Inspection and/or Maintenance
15B12124PR000229
Federal Prison System / Bureau of Prisons, Usp Hazelton. Building Inspection Services.
Response deadline
March 28, 2024 at 1:00 PM EDT
Closed 973 days ago. Posted March 16, 2024. Scheduled to archive April 12, 2024.
Get the next one like this from Federal Prison System / Bureau of Prisons by email, the day it is posted.Find my opportunities
This one closed in 2024
12 like it are open now in building inspection services
- Annual/Sem-i annual fire smoke inspections and auto door services l EKH
Department of Veterans Affairs, 255-Network Contract Office 15
SolicitationSmall businessNAICS 541350Leavenworth, KS36C25526Q0617Due tomorrowNov 27 - NTX Elevator Inspection - Amendment
Department of Veterans Affairs, 257-Network Contract Office 17
Combined synopsis and solicitationSDVOSBNAICS 541350Dallas, TX36C25727Q0031-0002Due in 4 daysNov 30 - Elevator Inspection and Certification Services
Bureau of Reclamation, Mp-Regional Office
Sources soughtNAICS 541350California140RR027Q0064Due in 7 daysDec 3
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 541350 (building inspection services), means no more than $11.5 million in average annual receipts, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of March 16, 2024. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
FY24 Annual Fire Suppression Inspection - Complex wide Sprinkler system PE 86170 Fire Suppression - Annual Wet Pipe (Sprinkler), Standpipes & Hoses (HAZ) FBOP Fire Suppression – Annual Wet Pipe (Sprinkler), Standpipes & Hoses (HAZ Complex Wide) Inspections Procedures/Requirements FBOP Fire Suppression – Annual Wet Pipe (Sprinkler), Standpipes & Hoses (HAZ Complex Wide) The Annual Fire Suppression Inspection, Testing, and Maintenance shall be conducted in compliance with the provisions contained within NFPA 25 (latest edition).
The following items, at a minimum, are to be included in the annual fire suppression inspection/test. This is a convenience list only. For more detailed methods and frequencies, refer to NFPA 25. Inspection/test by a qualified contractor. The procurement documentation shall specify the qualified contractor performs the inspection per ASME/ANSI (latest edition) or local requirements, provides a written report documenting the items inspected, and identify all noted deficiencies prior to final payment. Sprinklers Wet/Dry Spare Sprinklers Pipe and fittings. Hanger/seismic bracing Fire Pumps/Fire Pump Systems
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
March 16, 2024
Sources sought
Due March 28, 2024 at 1:00 PM EDT. SAM.gov, notice 6b4175281afd406c854b92867cac193a
Points of contact
- Kelly Brownk1roberts@bop.gov3043795156
- FCC Hazelton ProcurementHAX-ProcurementProp-S@bop.gov