{"canonical":"https://sealedbidder.com/opportunities/1333nd26qnb680282","key":"1333ND26QNB680282","url":"https://sealedbidder.com/opportunities/1333nd26qnb680282","title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","solicitation_number":"1333ND26QNB680282","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-06-23T15:00:00Z","first_posted":"2026-06-12","last_posted":"2026-09-04","department":"COMMERCE, DEPARTMENT OF","subagency":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6695","set_aside":null,"place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":"2431175","place_city_name":"Gaithersburg","winner":"SMARACT INC.","award_amount":"28690.00","publications":[{"notice_id":"674c08068719468b89835f8ab94c7b03","title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","solicitation_number":"1333ND26QNB680282","notice_type":"o","base_type":"r","posted":"2026-06-12","posted_at":"2026-06-12T17:58:04.806Z","due_at":"2026-06-23T15:00:00Z","due_date":"2026-06-23","cancelled":false,"archived":true,"archive_date":"2026-07-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/674c08068719468b89835f8ab94c7b03/view","enriched":true,"history":[{"index":6,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T18:04:42.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d","solicitation_number":"1333ND26QNB680282","parent_opportunity_id":"674c08068719468b89835f8ab94c7b03","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"},{"index":5,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-26T19:59:30.501Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"aebf972b7ff44d969c4344832d8192a2","solicitation_number":"NIST-AMD-NCNR-SSN26-04"},{"index":2,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T17:58:04.806Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"674c08068719468b89835f8ab94c7b03","solicitation_number":"1333ND26QNB680282","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"}]},{"notice_id":"7149831c9e1d40bc8eff87d0dcc7311d","title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","solicitation_number":"1333ND26QNB680282","notice_type":"o","base_type":"o","posted":"2026-06-12","posted_at":"2026-06-12T18:04:42.686Z","due_at":"2026-06-23T15:00:00Z","due_date":"2026-06-23","cancelled":false,"archived":true,"archive_date":"2026-07-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7149831c9e1d40bc8eff87d0dcc7311d/view","enriched":true,"history":[{"index":9,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-09-04T15:03:17.697Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"33797c49161f42c3931a2c568741065d","solicitation_number":"1333ND26PNB680245","related_opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d"},{"index":6,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T18:04:42.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d","solicitation_number":"1333ND26QNB680282","parent_opportunity_id":"674c08068719468b89835f8ab94c7b03","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"},{"index":4,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-26T19:59:30.501Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"aebf972b7ff44d969c4344832d8192a2","solicitation_number":"NIST-AMD-NCNR-SSN26-04"},{"index":2,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T17:58:04.806Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"674c08068719468b89835f8ab94c7b03","solicitation_number":"1333ND26QNB680282","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"}]},{"notice_id":"33797c49161f42c3931a2c568741065d","title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","solicitation_number":"1333ND26PNB680245","notice_type":"a","base_type":"o","posted":"2026-09-04","posted_at":"2026-09-04T15:03:17.697Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-09-19","removed_at":null,"award_number":"1333ND26PNB680245","awardee_name":"SMARACT INC.","amount":"28690.00","link_sam":"https://sam.gov/workspace/contract/opp/33797c49161f42c3931a2c568741065d/view","enriched":true,"history":[{"index":5,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-09-04T15:03:17.697Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"33797c49161f42c3931a2c568741065d","solicitation_number":"1333ND26PNB680245","related_opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d"},{"index":2,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T18:04:42.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d","solicitation_number":"1333ND26QNB680282","parent_opportunity_id":"674c08068719468b89835f8ab94c7b03","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"}]}],"latest_notice_id":"33797c49161f42c3931a2c568741065d","first_type":"o","notices":[{"dates":{"posted":"2026-06-12","posted_at":"2026-06-12T17:58:04.806Z","created_at":"2026-06-12T17:55:40.126Z","modified_at":"2026-07-09T03:55:45.636Z","response_deadline":{"raw":"2026-06-23T11:00:00-04:00","utc":"2026-06-23T15:00:00Z","date":"2026-06-23","time":"11:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/674c08068719468b89835f8ab94c7b03/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","agency":{"office":{"code":"1333ND","name":"DEPT OF COMMERCE NIST"},"subtier":{"code":"1341","name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY"},"department":{"code":"013","name":"COMMERCE, DEPARTMENT OF"},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"organization_id":"100182905","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-08","archive_type":"auto15"},"history":[{"index":6,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T18:04:42.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d","solicitation_number":"1333ND26QNB680282","parent_opportunity_id":"674c08068719468b89835f8ab94c7b03","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"},{"index":5,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-26T19:59:30.501Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"aebf972b7ff44d969c4344832d8192a2","solicitation_number":"NIST-AMD-NCNR-SSN26-04"},{"index":2,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T17:58:04.806Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"674c08068719468b89835f8ab94c7b03","solicitation_number":"1333ND26QNB680282","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"}],"contacts":[{"name":"Robert Singman","role":"primary","email":"robert.singman@nist.gov","phone":"3019756388"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"674c08068719468b89835f8ab94c7b03","lineage_id":"674c08068719468b89835f8ab94c7b03","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T08:59:15.121508705Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"3861b9b98756fc5a55118c6ed8218352a74e3b7d8c3f94cb167a6bf0ac032030","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-02T08:59:15.121508705Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest.&nbsp; This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam.&nbsp; Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360&deg;, with high resolution.&nbsp; The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter.&nbsp; The mass of a grating, including a holder is of order 100 g.&nbsp; The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable.&nbsp; For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm.&nbsp; The third grating is separated by up to 5 m.&nbsp;The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.</p>\n\n<p>This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.&nbsp;</p>","text":"The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest. This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam. Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360°, with high resolution. The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter. The mass of a grating, including a holder is of order 100 g. The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable. For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm. The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.\n\nThis procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"1333ND26QNB680282","place_of_performance":{"zip":"20899","city":{"code":"31175","name":"Gaithersburg"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6695"},{"dates":{"posted":"2026-06-12","posted_at":"2026-06-12T18:04:42.686Z","created_at":"2026-06-12T18:04:05.897Z","modified_at":"2026-07-09T03:55:45.636Z","response_deadline":{"raw":"2026-06-23T11:00:00-04:00","utc":"2026-06-23T15:00:00Z","date":"2026-06-23","time":"11:00:00","timezone":"America/New_York","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7149831c9e1d40bc8eff87d0dcc7311d/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","agency":{"office":{"code":"1333ND","name":"DEPT OF COMMERCE NIST"},"subtier":{"code":"1341","name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY"},"department":{"code":"013","name":"COMMERCE, DEPARTMENT OF"},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"organization_id":"100182905","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-07-08","archive_type":"auto15"},"history":[{"index":9,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-09-04T15:03:17.697Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"33797c49161f42c3931a2c568741065d","solicitation_number":"1333ND26PNB680245","related_opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d"},{"index":6,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T18:04:42.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d","solicitation_number":"1333ND26QNB680282","parent_opportunity_id":"674c08068719468b89835f8ab94c7b03","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"},{"index":4,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-05-26T19:59:30.501Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"aebf972b7ff44d969c4344832d8192a2","solicitation_number":"NIST-AMD-NCNR-SSN26-04"},{"index":2,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T17:58:04.806Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"674c08068719468b89835f8ab94c7b03","solicitation_number":"1333ND26QNB680282","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"}],"contacts":[{"name":"Robert Singman","role":"primary","email":"robert.singman@nist.gov","phone":"3019756388"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"7149831c9e1d40bc8eff87d0dcc7311d","lineage_id":"674c08068719468b89835f8ab94c7b03","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-02T09:01:21.619339917Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"9cc33b531c4b432c0fab5e541052b1f336b33ff82ab148101f5b819e52e66de5","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-02T09:01:21.619339917Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest.&nbsp; This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam.&nbsp; Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360&deg;, with high resolution.&nbsp; The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter.&nbsp; The mass of a grating, including a holder is of order 100 g.&nbsp; The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable.&nbsp; For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm.&nbsp; The third grating is separated by up to 5 m.&nbsp;The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.</p>\n\n<p>This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.&nbsp;</p>","text":"The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest. This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam. Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360°, with high resolution. The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter. The mass of a grating, including a holder is of order 100 g. The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable. For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm. The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.\n\nThis procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"1333ND26QNB680282","place_of_performance":{"zip":"20899","city":{"code":"31175","name":"Gaithersburg"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6695"},{"award":{"date":"2026-09-04","amount":"28690.00","number":"1333ND26PNB680245","awardee":{"raw":"SMARACT INC. Berkeley CA 94704 USA","uei":"LFAVHCE9K2X3","cage":"75DT5","name":"SMARACT INC.","location":{"zip":"94704","city":{"code":"6000","name":"Berkeley"},"state":{"code":"CA","name":"California"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-09-04","posted_at":"2026-09-04T15:03:17.697Z","award_date":"2026-09-04","created_at":"2026-09-04T15:01:57.855Z","modified_at":"2026-09-19T05:06:52.613Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/33797c49161f42c3931a2c568741065d/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","agency":{"office":{"code":"1333ND","name":"DEPT OF COMMERCE NIST"},"subtier":{"code":"1341","name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY"},"department":{"code":"013","name":"COMMERCE, DEPARTMENT OF"},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"organization_id":"100182905","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-19","archive_type":"auto15"},"history":[{"index":5,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-09-04T15:03:17.697Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"33797c49161f42c3931a2c568741065d","solicitation_number":"1333ND26PNB680245","related_opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d"},{"index":2,"title":"Upgrade of the Cold Neutron Imaging Instrument, Phase Grating Roll Alignment System","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-06-12T18:04:42.686Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"7149831c9e1d40bc8eff87d0dcc7311d","solicitation_number":"1333ND26QNB680282","parent_opportunity_id":"674c08068719468b89835f8ab94c7b03","related_opportunity_id":"aebf972b7ff44d969c4344832d8192a2"}],"contacts":[{"name":"Robert Singman","role":"primary","email":"robert.singman@nist.gov","phone":"3019756388"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"33797c49161f42c3931a2c568741065d","lineage_id":"674c08068719468b89835f8ab94c7b03","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T03:16:50.820163985Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a772c9fcff085024bf64c889af4fae89-30\"","fetched_at":"2026-09-19T03:44:47.683076529Z","row_sha256":"a284c8db35a9163a523873726b2026d7b9b19c3d0d133c19c38fac5d06817668","last_modified":"2026-09-19T03:30:54Z"},"updated_at":"2026-09-24T03:16:50.820163985Z","first_seen_at":"2026-09-15T22:52:52.472456Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"1333ND26PNB680245","place_of_performance":{"zip":"20899","city":{"code":"31175","name":"Gaithersburg"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"6695"}],"due_at":"2026-06-23T15:00:00Z","due_date":"2026-06-23","closes_at":"2026-06-23T15:00:00Z","awardable":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"LFAVHCE9K2X3","amount":"28690.00","linked_awards":3,"cancelled":false,"archived":true,"updated_at":"2026-09-24T03:25:58.922164Z","principal_notice_id":"7149831c9e1d40bc8eff87d0dcc7311d","description":{"text":"The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest. This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam. Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360°, with high resolution. The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter. The mass of a grating, including a holder is of order 100 g. The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable. For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm. The third grating is separated by up to 5 m. The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.\n\nThis procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.","html":"<p>The NIST neutron imaging team, in the Radiation Physics Division of the Physical Measurement Laboratory, is developing a far-field grating neutron interferometer to measure the projection of the pair correlation function, G(Z), of a sample of interest.&nbsp; This interferometer geometry requires precision alignment of 3 gratings about the roll direction of the neutron beam.&nbsp; Since G(Z) is a vector quantity, aligned perpendicular to the grating direction, the grating alignment stages need to be able to rotate a full 360&deg;, with high resolution.&nbsp; The gratings are lines etched into silicon wafers, where the period of the lines is of order 1 micrometer and the wafers are 100 mm in diameter.&nbsp; The mass of a grating, including a holder is of order 100 g.&nbsp; The interferometer pattern is measured by translating one of the gratings, so that that mass of the alignment system must be kept to as low as achievable.&nbsp; For control hardware, the separation of two of the gratings along the beam ranges from 1 mm to 300 mm.&nbsp; The third grating is separated by up to 5 m.&nbsp;The overall grating alignment system requires translating the gratings in the vertical direction, requiring that the grating roll stages (which much also translate) be less than 1 kg in mass.</p>\n\n<p>This procurement is to obtain quantity three high precision rotation stages (resolution better than 0.00005 degrees) with a clear aperture to allow the beam to pass unattenuated and required cabling, control hardware, and control software.&nbsp;</p>","origin":"detail"},"contacts":[{"name":"Robert Singman","role":"primary","email":"robert.singman@nist.gov","phone":"3019756388"}],"place_of_performance":{"zip":"20899","city":{"code":"31175","name":"Gaithersburg"},"state":{"code":"MD","name":"Maryland"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"df80c894568442c38b3c1a4cdc66df68","name":"Attachment 2- Applicable Provisions and Clauses.pdf","kind":"file","mime_type":".pdf","size_bytes":197125,"posted_at":"2026-06-12T17:58:04.806Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/df80c894568442c38b3c1a4cdc66df68/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_1333ND26PNB680245_1341_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_1333ND26PNB680245_1341_-NONE-_-NONE-/","piid":"1333ND26PNB680245","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"LFAVHCE9K2X3","recipient_name":"SMARACT INC.","recipient_uei":"LFAVHCE9K2X3","recipient_cage":"75DT5","recipient_city":"BERKELEY","recipient_state":"CA","sub_name":"National Institute of Standards and Technology","office_name":"DEPT OF COMMERCE NIST","office_key":"o-1333ND","first_action_date":"2026-09-04","last_action_date":"2026-09-04","actions":1,"obligated":"28690.00","current_total_value":"28690.00","potential_total_value":"28690.00","naics":"334516","psc":"6640","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":1,"description":"OU68-FY26-499-NEW UPGRADE OF THE COLD NEUTRON IMAGING INSTRUMENT, PHASE GRATING ROLL ALIGNMENT SYSTEM","method":"piid","confidence":"high","evidence":["award number 1333ND26PNB680245 equals the contract number","same awarding office 1333ND"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"NISTSS26CHIPS13","latest_notice_id":"0124b2bd52b742b8a14350289fc0626d","title":"Sources Sought Notice for Mid-IR Optical Frequency Comb","solicitation_number":"NIST-SS26-CHIPS-13","notice_type":"r","first_type":"r","first_posted":"2025-11-19","last_posted":"2025-11-19","notices":1,"due_at":"2026-12-03T22:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"573067270009","latest_notice_id":"ff7a062def984637aae7109d5026d17c","title":"Sources Sought: Polarization-Entangled Photon Source","solicitation_number":"573067-27-0009","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6035","set_aside":null,"state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"NISTSS26CHIPS16","latest_notice_id":"f06db812fc2549fc995d22d26b2dbc5c","title":"Sources Sought Notice for Continuous Wave Parametric Oscillator (CW OPO) Laser System","solicitation_number":"NIST-SS26-CHIPS-16","notice_type":"r","first_type":"r","first_posted":"2025-11-20","last_posted":"2025-11-20","notices":1,"due_at":"2026-12-05T16:00:00Z","due_date":"2026-12-05","closes_at":"2026-12-05T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"1333ND27R0001","latest_notice_id":"bb1373be92d643798f65aae817d7aba0","title":"CUP Preventative Maintenance and Repair, NIST, Boulder, CO","solicitation_number":"1333ND27R0001","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-09T22:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"811310","psc":"Z1JZ","set_aside":"SBA","state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":55,"indexable":false}