{"canonical":"https://sealedbidder.com/opportunities/1333nd26qnb640601","key":"1333ND26QNB640601","url":"https://sealedbidder.com/opportunities/1333nd26qnb640601","title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","solicitation_number":"1333ND26QNB640601","notice_type":"o","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-09-21T16:00:00Z","first_posted":"2026-09-15","last_posted":"2026-09-17","department":"COMMERCE, DEPARTMENT OF","subagency":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6630","set_aside":"SBA","place_state":"MD","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"24031","place_county_name":"Montgomery County","place_city":"2431175","place_city_name":"Gaithersburg","winner":"CUSTOM SOLUTIONS GROUP, INC.","award_amount":null,"publications":[{"notice_id":"a31c5d87fbd7421fa2623257931cec77","title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","solicitation_number":"1333ND26QNB640601","notice_type":"o","base_type":"o","posted":"2026-09-15","posted_at":"2026-09-15T13:03:12.612Z","due_at":"2026-09-21T16:00:00Z","due_date":"2026-09-21","cancelled":false,"archived":true,"archive_date":"2026-10-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a31c5d87fbd7421fa2623257931cec77/view","enriched":true,"history":[{"index":1,"title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-15T13:03:12.612Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"a31c5d87fbd7421fa2623257931cec77","solicitation_number":"1333ND26QNB640601"}]},{"notice_id":"c3d1218425364835b7b429d402a51245","title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","solicitation_number":"1333ND26QNB640601","notice_type":"o","base_type":"o","posted":"2026-09-17","posted_at":"2026-09-17T17:27:30.056Z","due_at":"2026-09-21T16:00:00Z","due_date":"2026-09-21","cancelled":false,"archived":true,"archive_date":"2026-10-06","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c3d1218425364835b7b429d402a51245/view","enriched":true,"history":[{"index":2,"title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-17T17:27:30.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c3d1218425364835b7b429d402a51245","solicitation_number":"1333ND26QNB640601","parent_opportunity_id":"a31c5d87fbd7421fa2623257931cec77"},{"index":1,"title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-15T13:03:12.612Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"a31c5d87fbd7421fa2623257931cec77","solicitation_number":"1333ND26QNB640601"}]}],"latest_notice_id":"c3d1218425364835b7b429d402a51245","first_type":"o","notices":[{"dates":{"posted":"2026-09-15","posted_at":"2026-09-15T13:03:12.612Z","created_at":"2026-09-15T12:54:03.447Z","modified_at":"2026-09-15T13:03:12.616Z","response_deadline":{"raw":"2026-09-21T12:00:00-04:00","utc":"2026-09-21T16:00:00Z","date":"2026-09-21","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a31c5d87fbd7421fa2623257931cec77/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","agency":{"office":{"code":"1333ND","name":"DEPT OF COMMERCE NIST"},"subtier":{"code":"1341","name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY"},"department":{"code":"013","name":"COMMERCE, DEPARTMENT OF"},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-06","archive_type":"auto15"},"history":[{"index":1,"title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-15T13:03:12.612Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"a31c5d87fbd7421fa2623257931cec77","solicitation_number":"1333ND26QNB640601"}],"contacts":[{"name":"Rudolph Spencer","role":"primary","email":"rudolph.spencer@nist.gov"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"a31c5d87fbd7421fa2623257931cec77","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"a31c5d87fbd7421fa2623257931cec77","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-16T08:44:29.641765808Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"f29807c6899737e255fcb5c57c123195436686c10a4aede119d550e9a2572a9e","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-16T07:48:43.123177Z"},"description":{"html":"<p>See attached.</p>","text":"See attached.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"1333ND26QNB640601","place_of_performance":{"zip":"20899","city":{"name":"Gaithersburg"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"6630"},{"dates":{"posted":"2026-09-17","posted_at":"2026-09-17T17:27:30.056Z","created_at":"2026-09-17T17:11:57.430Z","modified_at":"2026-09-17T17:27:30.060Z","response_deadline":{"raw":"2026-09-21T12:00:00-04:00","utc":"2026-09-21T16:00:00Z","date":"2026-09-21","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c3d1218425364835b7b429d402a51245/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","agency":{"office":{"code":"1333ND","name":"DEPT OF COMMERCE NIST"},"subtier":{"code":"1341","name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY"},"department":{"code":"013","name":"COMMERCE, DEPARTMENT OF"},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"publication":"published","archive_date":"2026-10-06","archive_type":"auto15"},"history":[{"index":2,"title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-17T17:27:30.056Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"c3d1218425364835b7b429d402a51245","solicitation_number":"1333ND26QNB640601","parent_opportunity_id":"a31c5d87fbd7421fa2623257931cec77"},{"index":1,"title":"Gas Chromatograph with a Thermal Conductivity Detector and Flame Ioniztion Detector with Methanizer","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-09-15T13:03:12.612Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"a31c5d87fbd7421fa2623257931cec77","solicitation_number":"1333ND26QNB640601"}],"contacts":[{"name":"Rudolph Spencer","role":"primary","email":"rudolph.spencer@nist.gov"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"c3d1218425364835b7b429d402a51245","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"a31c5d87fbd7421fa2623257931cec77","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-18T04:56:56.998218710Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"be5b55b19b729af7bdd453e30d78434d-26\"","fetched_at":"2026-10-06T03:48:34.605332942Z","row_sha256":"e9bca984d4474ea003edf553cbfb617664ce8cce677c850f2d890c0f8dba850a","last_modified":"2026-10-06T03:30:43Z"},"updated_at":"2026-10-06T03:48:34.605332942Z","first_seen_at":"2026-09-18T03:58:46.954081762Z"},"description":{"html":"<p><strong>***Amendment 0001****</strong></p>\n\n<p>Amendment 0001 provides resposnes to questions received in response to the solicitation.</p>\n\n<p><strong>Q.1.</strong>&nbsp; I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system?</p>\n\n<p><strong>A.1</strong>. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, &nbsp;and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 &ndash; 200) ppb.</p>\n\n<p><strong>Q.2.</strong> What types of samples will be tested?</p>\n\n<p><strong>A.2. </strong>This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases.</p>\n\n<p><strong>Q.3.</strong> What specific substances or compounds need to be detected or analyzed in these samples?</p>\n\n<p>If available, please also share any specific testing standards or requirements. With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly.</p>\n\n<p><strong>A.3</strong>. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, &nbsp;and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector.</p>\n\n<p>For improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts. &nbsp;</p>\n\n<p><strong>Q.4.</strong>&nbsp;Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)?&nbsp;</p>\n\n<p><strong>A.4.&nbsp;</strong>The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel.</p>\n\n<p>There is not an extension to the solicitation as a result of this amendment.</p>\n\n<p>The question period for this soliciation will close today, September 17,2026, at 4:00 PM ET.</p>\n\n<p><strong>End of Amendment 0001</strong></p>\n\n<p><strong>********</strong></p>\n\n<p>See attached.</p>","text":"***Amendment 0001****\n\nAmendment 0001 provides resposnes to questions received in response to the solicitation.\n\nQ.1. I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system?\n\nA.1. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 – 200) ppb.\n\nQ.2. What types of samples will be tested?\n\nA.2. This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases.\n\nQ.3. What specific substances or compounds need to be detected or analyzed in these samples?\n\nIf available, please also share any specific testing standards or requirements. With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly.\n\nA.3. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector.\n\nFor improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts.\n\nQ.4. Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)?\n\nA.4. The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel.\n\nThere is not an extension to the solicitation as a result of this amendment.\n\nThe question period for this soliciation will close today, September 17,2026, at 4:00 PM ET.\n\nEnd of Amendment 0001\n\n********\n\nSee attached.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"1333ND26QNB640601","place_of_performance":{"zip":"20899","city":{"name":"Gaithersburg"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"6630"}],"due_at":"2026-09-21T16:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T16:00:00Z","awardable":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"M7DHRHBB8GM8","amount":null,"linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-10-07T05:24:59.287449Z","principal_notice_id":"c3d1218425364835b7b429d402a51245","description":{"text":"***Amendment 0001****\n\nAmendment 0001 provides resposnes to questions received in response to the solicitation.\n\nQ.1. I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system?\n\nA.1. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 – 200) ppb.\n\nQ.2. What types of samples will be tested?\n\nA.2. This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases.\n\nQ.3. What specific substances or compounds need to be detected or analyzed in these samples?\n\nIf available, please also share any specific testing standards or requirements. With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly.\n\nA.3. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector.\n\nFor improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts.\n\nQ.4. Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)?\n\nA.4. The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel.\n\nThere is not an extension to the solicitation as a result of this amendment.\n\nThe question period for this soliciation will close today, September 17,2026, at 4:00 PM ET.\n\nEnd of Amendment 0001\n\n********\n\nSee attached.","html":"<p><strong>***Amendment 0001****</strong></p>\n\n<p>Amendment 0001 provides resposnes to questions received in response to the solicitation.</p>\n\n<p><strong>Q.1.</strong>&nbsp; I am reviewing Notice ID 1333ND26QNB640601 and would appreciate some clarification regarding the analytical requirements. Would you be able to share the analytes of interest, the required detection limits, and the expected concentration ranges for the system?</p>\n\n<p><strong>A.1</strong>. This analyzer will be used for the analysis of binary gas mixtures in nitrogen or air balance gases. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, &nbsp;and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector. This analyzer will also be used for analyses of ambient level CO in air mixtures, ranging from (40 &ndash; 200) ppb.</p>\n\n<p><strong>Q.2.</strong> What types of samples will be tested?</p>\n\n<p><strong>A.2. </strong>This analyzer will be used for analyses of high pressure gas mixtures in nitrogen or air balance gases.</p>\n\n<p><strong>Q.3.</strong> What specific substances or compounds need to be detected or analyzed in these samples?</p>\n\n<p>If available, please also share any specific testing standards or requirements. With this information, we can better understand your application and recommend a suitable instrument configuration and quotation accordingly.</p>\n\n<p><strong>A.3</strong>. As stated above, this analyzer will be used for the analysis of high pressure gas mixtures delivered at or below 25 psig. The analyses performed will include a wide range of gaseous standard reference materials including: 1 ppm methane in air and 250 ppm carbon monoxide in nitrogen, both analyzed using the flame ionization detector with methanation, &nbsp;and 0.5 % carbon dioxide in nitrogen analyzed using the thermal conductivity detector.</p>\n\n<p>For improved precision, temperature ramping and stable detector response are required to achieve baseline resolution between components in air balance gas. In all cases the repeatability should be at or below 0.2 % relative area counts. &nbsp;</p>\n\n<p><strong>Q.4.</strong>&nbsp;Regarding your software requirements, you cite Visual Basic Version 6.0. Would that software be able to generate an XML file to communicate with our software (CompassCDS)?&nbsp;</p>\n\n<p><strong>A.4.&nbsp;</strong>The visual basic software was developed to support communication between the GC software and a 12-port dead-end VICI sampling valve. The software can retrieve data from a txt file generated by the GC software and output the data to excel.</p>\n\n<p>There is not an extension to the solicitation as a result of this amendment.</p>\n\n<p>The question period for this soliciation will close today, September 17,2026, at 4:00 PM ET.</p>\n\n<p><strong>End of Amendment 0001</strong></p>\n\n<p><strong>********</strong></p>\n\n<p>See attached.</p>","origin":"detail"},"contacts":[{"name":"Rudolph Spencer","role":"primary","email":"rudolph.spencer@nist.gov"}],"place_of_performance":{"zip":"20899","city":{"name":"Gaithersburg"},"state":{"code":"MD"},"country":{"code":"USA"}},"office_address":{"zip":"20899","city":"GAITHERSBURG","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"9860957c0ba34e6ba99f752d23441634","name":"1333ND26QNB640601 FormSF1449.pdf","kind":"file","mime_type":".pdf","size_bytes":1567626,"posted_at":"2026-09-15T13:03:12.612Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9860957c0ba34e6ba99f752d23441634/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_1333ND26PNB640652_1341_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_1333ND26PNB640652_1341_-NONE-_-NONE-/","piid":"1333ND26PNB640652","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"M7DHRHBB8GM8","recipient_name":"CUSTOM SOLUTIONS GROUP, INC.","recipient_uei":"M7DHRHBB8GM8","recipient_cage":"70NJ3","recipient_city":"KATY","recipient_state":"TX","sub_name":"National Institute of Standards and Technology","office_name":"DEPT OF COMMERCE NIST","office_key":"o-1333ND","first_action_date":"2026-09-23","last_action_date":"2026-09-23","actions":1,"obligated":"85863.00","current_total_value":"85863.00","potential_total_value":"85863.00","naics":"334516","psc":"6640","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":3,"description":"OU63-FY26-205-NEW - GAS CHROMATOGRAPH WITH TCD AND FID-METHANATION DETECTORS.","method":"solicitation","confidence":"high","evidence":["solicitation number 1333ND26QNB640601 equals the FPDS solicitation identifier","same awarding office 1333ND"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"NISTSS26CHIPS13","latest_notice_id":"0124b2bd52b742b8a14350289fc0626d","title":"Sources Sought Notice for Mid-IR Optical Frequency Comb","solicitation_number":"NIST-SS26-CHIPS-13","notice_type":"r","first_type":"r","first_posted":"2025-11-19","last_posted":"2025-11-19","notices":1,"due_at":"2026-12-03T22:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"573067270009","latest_notice_id":"ff7a062def984637aae7109d5026d17c","title":"Sources Sought: Polarization-Entangled Photon Source","solicitation_number":"573067-27-0009","notice_type":"r","first_type":"r","first_posted":"2026-11-23","last_posted":"2026-11-23","notices":3,"due_at":"2026-12-04T19:00:00Z","due_date":"2026-12-04","closes_at":"2026-12-04T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6035","set_aside":null,"state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"NISTSS26CHIPS16","latest_notice_id":"f06db812fc2549fc995d22d26b2dbc5c","title":"Sources Sought Notice for Continuous Wave Parametric Oscillator (CW OPO) Laser System","solicitation_number":"NIST-SS26-CHIPS-16","notice_type":"r","first_type":"r","first_posted":"2025-11-20","last_posted":"2025-11-20","notices":1,"due_at":"2026-12-05T16:00:00Z","due_date":"2026-12-05","closes_at":"2026-12-05T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"},{"key":"1333ND27R0001","latest_notice_id":"bb1373be92d643798f65aae817d7aba0","title":"CUP Preventative Maintenance and Repair, NIST, Boulder, CO","solicitation_number":"1333ND27R0001","notice_type":"p","first_type":"p","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-12-09T22:00:00Z","due_date":"2026-12-09","closes_at":"2026-12-09T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"811310","psc":"Z1JZ","set_aside":"SBA","state":"CO","county":"08013","county_name":"Boulder County","city":"0807850","city_name":"Boulder","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open":[{"key":"NOIOLAOCC27000836","latest_notice_id":"8eb0ea7110504ca7bcc6eb99ffeb6296","title":"Notice of Intent - Illumina MiSeq i100 series instruments","solicitation_number":"NOI-OLAO-CC-27-000836","notice_type":"p","first_type":"p","first_posted":"2026-11-12","last_posted":"2026-11-12","notices":1,"due_at":"2026-11-27T17:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7529","sub_name":"NATIONAL INSTITUTES OF HEALTH","office_key":"o-75N900","office_name":"NATIONAL INSTITUTES OF HEALTH - CC","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2407125","city_name":"Bethesda","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-13T05:18:31.697344Z"},{"key":"NISTMMLFY27SS01","latest_notice_id":"850a8fc718dc434d89f77ecfcb0c4251","title":"Graphite Furnace Atomic Absorption Spectrometer","solicitation_number":"NIST-MML-FY27-SS01","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-28T19:00:00Z","due_date":"2026-11-28","closes_at":"2026-11-28T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-013","dept_name":"COMMERCE, DEPARTMENT OF","sub_key":"s-1341","sub_name":"NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY","office_key":"o-1333ND","office_name":"DEPT OF COMMERCE NIST","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2431175","city_name":"Gaithersburg","country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"W911QX27QA015","latest_notice_id":"4bf048ddb6e84735a4f6e6589aeafac6","title":"Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.","solicitation_number":"W911QX27QA015","notice_type":"o","first_type":"o","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-01T16:59:00Z","due_date":"2026-12-01","closes_at":"2026-12-01T16:59:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911QX","office_name":"W6QK ACC-APG ADELPHI","naics":"334516","psc":"6640","set_aside":null,"state":"MD","county":"24025","county_name":"Harford County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"}],"similar_open_total":53,"indexable":false}