{"canonical":"https://sealedbidder.com/opportunities/12fpc326q0002","key":"12FPC326Q0002","url":"https://sealedbidder.com/opportunities/12fpc326q0002","title":"Electrical Work at the Bridger Plant Materials Center, Bridger, Montana","solicitation_number":"12FPC326Q0002","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-03-03T20:00:00Z","first_posted":"2026-02-17","last_posted":"2026-02-17","department":"AGRICULTURE, DEPARTMENT OF","subagency":"FARM PRODUCTION AND CONSERVATION BUSINESS CENTER","office":"FPAC BUS CNTR-ACQ DIV","naics":"238210","psc":"N059","set_aside":"SBA","place_state":"MT","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"30009","place_county_name":"Carbon County","place_city":"3009475","place_city_name":"Bridger","winner":"SPEIGHTS GROUP LLC","award_amount":null,"publications":[{"notice_id":"8d227744c2ea42b78d5984c16cbf86d4","title":"Electrical Work at the Bridger Plant Materials Center, Bridger, Montana","solicitation_number":"12FPC326Q0002","notice_type":"k","base_type":"k","posted":"2026-02-17","posted_at":"2026-02-17T15:13:53.126Z","due_at":"2026-03-03T20:00:00Z","due_date":"2026-03-03","cancelled":false,"archived":true,"archive_date":"2026-03-18","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8d227744c2ea42b78d5984c16cbf86d4/view","enriched":true,"history":[{"index":3,"title":"Electrical Work at the Bridger Plant Materials Center, Bridger, Montana","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-17T15:13:53.126Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"8d227744c2ea42b78d5984c16cbf86d4","solicitation_number":"12FPC326Q0002"}]}],"latest_notice_id":"8d227744c2ea42b78d5984c16cbf86d4","first_type":"k","notices":[{"dates":{"posted":"2026-02-17","posted_at":"2026-02-17T15:13:53.126Z","created_at":"2026-02-17T14:49:54.742Z","modified_at":"2026-03-19T03:55:44.197Z","response_deadline":{"raw":"2026-03-03T15:00:00-05:00","utc":"2026-03-03T20:00:00Z","date":"2026-03-03","time":"15:00:00","timezone":"America/New_York","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8d227744c2ea42b78d5984c16cbf86d4/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Electrical Work at the Bridger Plant Materials Center, Bridger, Montana","agency":{"office":{"code":"12FPAC","name":"FPAC BUS CNTR-ACQ DIV"},"subtier":{"code":"12D0","name":"FARM PRODUCTION AND CONSERVATION BUSINESS CENTER"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"20250","city":"WASHINGTON","state":"DC","country":"USA"},"organization_id":"500036392","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-03-18","archive_type":"auto15"},"history":[{"index":3,"title":"Electrical Work at the Bridger Plant Materials Center, Bridger, Montana","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-02-17T15:13:53.126Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"8d227744c2ea42b78d5984c16cbf86d4","solicitation_number":"12FPC326Q0002"}],"contacts":[{"name":"Mark Domingo","role":"primary","email":"mark.domingo@usda.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"8d227744c2ea42b78d5984c16cbf86d4","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"8d227744c2ea42b78d5984c16cbf86d4","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-13T00:43:59.581398919Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"a729ecb7cbaf566ebe5dcc25629a41f5567ece4d25396d16f8e6a092bbcf55dc","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-13T00:43:59.581398919Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p></p>\n\n<p>Please see Attaachment 1 Statement of Work for further detailed description of services.</p>\n\n<p>This work is for the United States Department of Agriculture - Natural Resources Conservation&nbsp;<br />\nService (NRCS) Bridger Plant Materials Center (PMC), located at 98 South River Rd., Bridger, MT&nbsp;<br />\n59014-9718. The work is to run three-phase power from the main distribution panel to a subpanel, to&nbsp;<br />\npower an existing outlet for charging a forklift and to install a new connection for the new&nbsp;<br />\nwalk-in seed cooler.<br />\nThe Contractor shall:</p>\n\n<p>Install conduit on the exterior of the building from the main distribution panel (MDP) unit to the&nbsp;<br />\ninterior wall behind the walk-in cooler, an approximate distance of 65 feet (from the 100amp panel&nbsp;<br />\nto the disconnect of the cooler is a total of 25 feet). The exterior wall is tin with insulation&nbsp;<br />\nand osb/plywood; interior walls are tin with insulation. Install a 100amp three-phase service feed&nbsp;<br />\nfrom the MDP to a new 100amp three-phase panel located next to the existing electric forklift&nbsp;<br />\nreceptacle. Conduit raceway will be metal EMT and Wire conductors will be copper THHN.<br />\nRemove the forklift breaker from the outdoor MDP and install a new 100amp Three Phase breaker in&nbsp;<br />\nplace. Re-feed the forklift disconnect out of the new 100amp sub panel to the existing forklift&nbsp;<br />\nreceptable, installing new solid conduit, wiring, and receptacle if required. Subpanel is 3 feet&nbsp;<br />\nfrom the forklift.</p>\n\n<p>Provide for electrical wiring of the Walk-in Cooler. Install a surface mount conduit from the new&nbsp;<br />\nThree Phase sub panel to the Walk-in Cooler area. Install a service disconnect switch for the&nbsp;<br />\nWalk-in<br />\nCooler. Wire from the service disconnect to the already pre-wired control panel located on the</p>\n\n<p>Walk-in Cooler. Note: Start up and testing of the Walk-in Cooler to be done by a separate HVAC<br />\nContractor provided by the owner.<br />\nDispose or recycle all materials removed from the site. Clean all spaces associated with the work.</p>\n\n<p>Timely completion of deliverables is essential to a successful outcome. All work must be completed&nbsp;<br />\nwithin 30 calendar days of the contract being awarded.<br />\nAll the materials and work required and performed by the contractors must be warrantied for one&nbsp;<br />\nyear<br />\nfrom the date of completion of the project.<br />\n&nbsp;</p>","text":"Please see Attaachment 1 Statement of Work for further detailed description of services.\n\nThis work is for the United States Department of Agriculture - Natural Resources Conservation\n\nService (NRCS) Bridger Plant Materials Center (PMC), located at 98 South River Rd., Bridger, MT\n\n59014-9718. The work is to run three-phase power from the main distribution panel to a subpanel, to\n\npower an existing outlet for charging a forklift and to install a new connection for the new\n\nwalk-in seed cooler.\n\nThe Contractor shall:\n\nInstall conduit on the exterior of the building from the main distribution panel (MDP) unit to the\n\ninterior wall behind the walk-in cooler, an approximate distance of 65 feet (from the 100amp panel\n\nto the disconnect of the cooler is a total of 25 feet). The exterior wall is tin with insulation\n\nand osb/plywood; interior walls are tin with insulation. Install a 100amp three-phase service feed\n\nfrom the MDP to a new 100amp three-phase panel located next to the existing electric forklift\n\nreceptacle. Conduit raceway will be metal EMT and Wire conductors will be copper THHN.\n\nRemove the forklift breaker from the outdoor MDP and install a new 100amp Three Phase breaker in\n\nplace. Re-feed the forklift disconnect out of the new 100amp sub panel to the existing forklift\n\nreceptable, installing new solid conduit, wiring, and receptacle if required. Subpanel is 3 feet\n\nfrom the forklift.\n\nProvide for electrical wiring of the Walk-in Cooler. Install a surface mount conduit from the new\n\nThree Phase sub panel to the Walk-in Cooler area. Install a service disconnect switch for the\n\nWalk-in\n\nCooler. Wire from the service disconnect to the already pre-wired control panel located on the\n\nWalk-in Cooler. Note: Start up and testing of the Walk-in Cooler to be done by a separate HVAC\n\nContractor provided by the owner.\n\nDispose or recycle all materials removed from the site. Clean all spaces associated with the work.\n\nTimely completion of deliverables is essential to a successful outcome. All work must be completed\n\nwithin 30 calendar days of the contract being awarded.\n\nAll the materials and work required and performed by the contractors must be warrantied for one\n\nyear\n\nfrom the date of completion of the project.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"12FPC326Q0002","place_of_performance":{"zip":"59014","city":{"code":"9475","name":"Bridger"},"state":{"code":"MT","name":"Montana"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"N059"}],"due_at":"2026-03-03T20:00:00Z","due_date":"2026-03-03","closes_at":"2026-03-03T20:00:00Z","awardable":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12D0","sub_name":"FARM PRODUCTION AND CONSERVATION BUSINESS CENTER","office_key":"o-12FPAC","office_name":"FPAC BUS CNTR-ACQ DIV","state":"MT","county":"30009","county_name":"Carbon County","city":"3009475","city_name":"Bridger","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"TEPRRGLN9SG5","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-10-13T02:02:04.521030Z","principal_notice_id":"8d227744c2ea42b78d5984c16cbf86d4","description":{"text":"Please see Attaachment 1 Statement of Work for further detailed description of services.\n\nThis work is for the United States Department of Agriculture - Natural Resources Conservation\n\nService (NRCS) Bridger Plant Materials Center (PMC), located at 98 South River Rd., Bridger, MT\n\n59014-9718. The work is to run three-phase power from the main distribution panel to a subpanel, to\n\npower an existing outlet for charging a forklift and to install a new connection for the new\n\nwalk-in seed cooler.\n\nThe Contractor shall:\n\nInstall conduit on the exterior of the building from the main distribution panel (MDP) unit to the\n\ninterior wall behind the walk-in cooler, an approximate distance of 65 feet (from the 100amp panel\n\nto the disconnect of the cooler is a total of 25 feet). The exterior wall is tin with insulation\n\nand osb/plywood; interior walls are tin with insulation. Install a 100amp three-phase service feed\n\nfrom the MDP to a new 100amp three-phase panel located next to the existing electric forklift\n\nreceptacle. Conduit raceway will be metal EMT and Wire conductors will be copper THHN.\n\nRemove the forklift breaker from the outdoor MDP and install a new 100amp Three Phase breaker in\n\nplace. Re-feed the forklift disconnect out of the new 100amp sub panel to the existing forklift\n\nreceptable, installing new solid conduit, wiring, and receptacle if required. Subpanel is 3 feet\n\nfrom the forklift.\n\nProvide for electrical wiring of the Walk-in Cooler. Install a surface mount conduit from the new\n\nThree Phase sub panel to the Walk-in Cooler area. Install a service disconnect switch for the\n\nWalk-in\n\nCooler. Wire from the service disconnect to the already pre-wired control panel located on the\n\nWalk-in Cooler. Note: Start up and testing of the Walk-in Cooler to be done by a separate HVAC\n\nContractor provided by the owner.\n\nDispose or recycle all materials removed from the site. Clean all spaces associated with the work.\n\nTimely completion of deliverables is essential to a successful outcome. All work must be completed\n\nwithin 30 calendar days of the contract being awarded.\n\nAll the materials and work required and performed by the contractors must be warrantied for one\n\nyear\n\nfrom the date of completion of the project.","html":"<p></p>\n\n<p>Please see Attaachment 1 Statement of Work for further detailed description of services.</p>\n\n<p>This work is for the United States Department of Agriculture - Natural Resources Conservation&nbsp;<br />\nService (NRCS) Bridger Plant Materials Center (PMC), located at 98 South River Rd., Bridger, MT&nbsp;<br />\n59014-9718. The work is to run three-phase power from the main distribution panel to a subpanel, to&nbsp;<br />\npower an existing outlet for charging a forklift and to install a new connection for the new&nbsp;<br />\nwalk-in seed cooler.<br />\nThe Contractor shall:</p>\n\n<p>Install conduit on the exterior of the building from the main distribution panel (MDP) unit to the&nbsp;<br />\ninterior wall behind the walk-in cooler, an approximate distance of 65 feet (from the 100amp panel&nbsp;<br />\nto the disconnect of the cooler is a total of 25 feet). The exterior wall is tin with insulation&nbsp;<br />\nand osb/plywood; interior walls are tin with insulation. Install a 100amp three-phase service feed&nbsp;<br />\nfrom the MDP to a new 100amp three-phase panel located next to the existing electric forklift&nbsp;<br />\nreceptacle. Conduit raceway will be metal EMT and Wire conductors will be copper THHN.<br />\nRemove the forklift breaker from the outdoor MDP and install a new 100amp Three Phase breaker in&nbsp;<br />\nplace. Re-feed the forklift disconnect out of the new 100amp sub panel to the existing forklift&nbsp;<br />\nreceptable, installing new solid conduit, wiring, and receptacle if required. Subpanel is 3 feet&nbsp;<br />\nfrom the forklift.</p>\n\n<p>Provide for electrical wiring of the Walk-in Cooler. Install a surface mount conduit from the new&nbsp;<br />\nThree Phase sub panel to the Walk-in Cooler area. Install a service disconnect switch for the&nbsp;<br />\nWalk-in<br />\nCooler. Wire from the service disconnect to the already pre-wired control panel located on the</p>\n\n<p>Walk-in Cooler. Note: Start up and testing of the Walk-in Cooler to be done by a separate HVAC<br />\nContractor provided by the owner.<br />\nDispose or recycle all materials removed from the site. Clean all spaces associated with the work.</p>\n\n<p>Timely completion of deliverables is essential to a successful outcome. All work must be completed&nbsp;<br />\nwithin 30 calendar days of the contract being awarded.<br />\nAll the materials and work required and performed by the contractors must be warrantied for one&nbsp;<br />\nyear<br />\nfrom the date of completion of the project.<br />\n&nbsp;</p>","origin":"detail"},"contacts":[{"name":"Mark Domingo","role":"primary","email":"mark.domingo@usda.gov"}],"place_of_performance":{"zip":"59014","city":{"code":"9475","name":"Bridger"},"state":{"code":"MT","name":"Montana"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"20250","city":"WASHINGTON","state":"DC","country":"USA"},"naics_codes":["238210"],"award":null,"attachments":[{"resource_id":"664790ca8c764543a9f699c5fc472376","name":"S01 - 12FPC326Q0002 Combined Synopsis Solicitation.pdf","kind":"file","mime_type":".pdf","size_bytes":197512,"posted_at":"2026-02-17T15:13:53.126Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/664790ca8c764543a9f699c5fc472376/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_12FPC326P0014_12D0_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_12FPC326P0014_12D0_-NONE-_-NONE-/","piid":"12FPC326P0014","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"TEPRRGLN9SG5","recipient_name":"SPEIGHTS GROUP LLC","recipient_uei":"TEPRRGLN9SG5","recipient_cage":"9EEW0","recipient_city":"INDIANA","recipient_state":"PA","sub_name":"Under Secretary for Farm and Foreign Agricultural Services","office_name":"FPAC BUS CNTR-ACQ DIV-WESTERN SEC","office_key":"o-12FPC3","first_action_date":"2026-04-14","last_action_date":"2026-04-14","actions":1,"obligated":"7600.00","current_total_value":"7600.00","potential_total_value":"7600.00","naics":"238210","psc":"N059","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":15,"description":"ELECTRICAL WORK AT THE BRIDGER PLANT MATERIALS CENTER, BRIDGER- RUN THREE-PHASE POWER FROM THE MAIN DISTRIBUTION PANEL TO A SUBPANEL, TO POWER AN EXISTING OUTLET FOR CHARGING A FORKLIFT AND TO INSTALL A NEW CONNECTION FOR THE NEW WALK-IN SEED COOLER","method":"solicitation","confidence":"high","evidence":["solicitation number 12FPC326Q0002 equals the FPDS solicitation identifier","same sub-agency 12D0"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"12FPC427Q0003","latest_notice_id":"0f5785279fa949a881b4626a080b7e80","title":"NRCS New Jersey Areawide Market Analysis","solicitation_number":"12FPC427Q0003","notice_type":"k","first_type":"k","first_posted":"2026-11-24","last_posted":"2026-11-24","notices":1,"due_at":"2026-12-08T22:00:00Z","due_date":"2026-12-08","closes_at":"2026-12-08T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12D0","sub_name":"FARM PRODUCTION AND CONSERVATION BUSINESS CENTER","office_key":"o-12FPAC","office_name":"FPAC BUS CNTR-ACQ DIV","naics":"531320","psc":"R411","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"FY27EXPERTREVIEWBOARDS","latest_notice_id":"ab2df14294ef4014a9cd5517a2891968","title":"FY27 - EXPERT REVIEW BOARDS","solicitation_number":"FY27-EXPERT-REVIEW-BOARDS","notice_type":"r","first_type":"r","first_posted":"2026-10-09","last_posted":"2026-10-15","notices":2,"due_at":"2027-09-30T10:00:00Z","due_date":"2027-09-30","closes_at":"2027-09-30T10:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12D0","sub_name":"FARM PRODUCTION AND CONSERVATION BUSINESS CENTER","office_key":"o-12FPAC","office_name":"FPAC BUS CNTR-ACQ DIV","naics":"541690","psc":"G008","set_aside":null,"state":"DC","county":"11001","county_name":"District of Columbia","city":"1150000","city_name":"Washington","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-16T03:38:05.572608Z"}],"similar_open":[{"key":"1240LU26Q0132","latest_notice_id":"7772e7cbaf1a46409b142ded751c8ec8","title":"USDA Forest Service - Hebgen Lake District Office Network Cabling and IT Room Improvements","solicitation_number":"1240LU26Q0132","notice_type":"k","first_type":"k","first_posted":"2026-09-24","last_posted":"2026-11-05","notices":4,"due_at":"2026-11-26T00:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1240LU","office_name":"USDA-FS, CSA INTERMOUNTAIN 9","naics":"238210","psc":"N061","set_aside":"SBA","state":"MT","county":"30031","county_name":"Gallatin County","city":"3079525","city_name":"West Yellowstone","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"36C24627Q0114","latest_notice_id":"9464cbfda7004348805568dfa367e88c","title":"5975--INSTALLATION OF PROXIMITY SENSORS FOR AUTOMATIC DOORS","solicitation_number":"36C24627Q0114","notice_type":"o","first_type":"r","first_posted":"2026-11-04","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-25T15:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C246","office_name":"246-NETWORK CONTRACTING OFFICE 6 (36C246)","naics":"238210","psc":"5975","set_aside":null,"state":"NC","county":"37051","county_name":"Cumberland County","city":"3722920","city_name":"Fayetteville","country":null,"place_scope":"nationwide","state_source":"sam_state_name","state_evidence":"Product purchase (PSC 5975)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"1232SA27Q0021","latest_notice_id":"8c35373e3e5c4e3bb88b3fb51c3ea2c1","title":"Electrical Installation of 5-Station Cubicle and One Single Hotel Desk Arrangement","solicitation_number":"1232SA27Q0021","notice_type":"k","first_type":"k","first_posted":"2026-11-20","last_posted":"2026-11-20","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12H2","sub_name":"AGRICULTURAL RESEARCH SERVICE","office_key":"o-1232SA","office_name":"USDA ARS AFM APD","naics":"238210","psc":"N059","set_aside":"SBA","state":"WI","county":"55025","county_name":"Dane County","city":"5548000","city_name":"Madison","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-21T05:30:25.727497Z"}],"similar_open_total":42,"indexable":false}