{"canonical":"https://sealedbidder.com/opportunities/12639526q0224","key":"12639526Q0224","url":"https://sealedbidder.com/opportunities/12639526q0224","title":"Reroute Power Supple at the Phoenix Rearing Facility","solicitation_number":"12639526Q0224","notice_type":"a","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-08-14T17:00:00Z","first_posted":"2026-07-16","last_posted":"2026-08-31","department":"AGRICULTURE, DEPARTMENT OF","subagency":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE","office":"USDA APHIS","naics":"238210","psc":"Y1AZ","set_aside":"SBA","place_state":"AZ","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"04013","place_county_name":"Maricopa County","place_city":"0455000","place_city_name":"Phoenix","winner":"NEW PHASE ELECTRICAL LLC","award_amount":"15971.00","publications":[{"notice_id":"75f240da8f1c49dbbb007c0a575e00d2","title":"Reroute Power Supple at the Phoenix Rearing Facility","solicitation_number":"12639526Q0224","notice_type":"k","base_type":"k","posted":"2026-07-16","posted_at":"2026-07-16T18:25:58.399Z","due_at":"2026-08-14T17:00:00Z","due_date":"2026-08-14","cancelled":false,"archived":true,"archive_date":"2026-08-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/75f240da8f1c49dbbb007c0a575e00d2/view","enriched":true,"history":[{"index":4,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":2,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-22T19:27:06.094Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"bbf95338c4544393a4f4d8a1bc7994ad","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":1,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-16T18:25:58.399Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2","solicitation_number":"12639526Q0224"}]},{"notice_id":"bbf95338c4544393a4f4d8a1bc7994ad","title":"Reroute Power Supple at the Phoenix Rearing Facility","solicitation_number":"12639526Q0224","notice_type":"k","base_type":"k","posted":"2026-07-22","posted_at":"2026-07-22T19:27:06.094Z","due_at":"2026-08-14T17:00:00Z","due_date":"2026-08-14","cancelled":false,"archived":true,"archive_date":"2026-08-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/bbf95338c4544393a4f4d8a1bc7994ad/view","enriched":true,"history":[{"index":4,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":2,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-22T19:27:06.094Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"bbf95338c4544393a4f4d8a1bc7994ad","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":1,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-16T18:25:58.399Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2","solicitation_number":"12639526Q0224"}]},{"notice_id":"875b02884a2d4efcaa95007b349b5192","title":"Reroute Power Supple at the Phoenix Rearing Facility","solicitation_number":"12639526Q0224","notice_type":"k","base_type":"k","posted":"2026-08-05","posted_at":"2026-08-05T16:43:51.426Z","due_at":"2026-08-14T17:00:00Z","due_date":"2026-08-14","cancelled":false,"archived":true,"archive_date":"2026-08-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/875b02884a2d4efcaa95007b349b5192/view","enriched":true,"history":[{"index":10,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-31T17:50:15.990Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"8b149d52eb4d4ccfb9ab059d7f5ce682","solicitation_number":"12639526C0042","related_opportunity_id":"875b02884a2d4efcaa95007b349b5192"},{"index":7,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-18T16:35:50.986Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"a26b6f4dc4f14c7380600a16a49e3e17","solicitation_number":"12639526C0042","related_opportunity_id":"875b02884a2d4efcaa95007b349b5192"},{"index":5,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":2,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-22T19:27:06.094Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"bbf95338c4544393a4f4d8a1bc7994ad","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":1,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-16T18:25:58.399Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2","solicitation_number":"12639526Q0224"}]},{"notice_id":"a26b6f4dc4f14c7380600a16a49e3e17","title":"Reroute Power Supple at the Phoenix Rearing Facility","solicitation_number":"12639526C0042","notice_type":"a","base_type":"k","posted":"2026-08-18","posted_at":"2026-08-18T16:35:50.986Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-08-29","removed_at":null,"award_number":"12639526C0042","awardee_name":"New Phase Electrical LLC","amount":"15971.00","link_sam":"https://sam.gov/workspace/contract/opp/a26b6f4dc4f14c7380600a16a49e3e17/view","enriched":true,"history":[{"index":5,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-18T16:35:50.986Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"a26b6f4dc4f14c7380600a16a49e3e17","solicitation_number":"12639526C0042","related_opportunity_id":"875b02884a2d4efcaa95007b349b5192"},{"index":3,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"}]},{"notice_id":"8b149d52eb4d4ccfb9ab059d7f5ce682","title":"Reroute Power Supple at the Phoenix Rearing Facility","solicitation_number":"12639526C0042","notice_type":"a","base_type":"k","posted":"2026-08-31","posted_at":"2026-08-31T17:50:15.990Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-08-31","removed_at":null,"award_number":"12639526C0042","awardee_name":"New Phase Electrical LLC","amount":"15971.00","link_sam":"https://sam.gov/workspace/contract/opp/8b149d52eb4d4ccfb9ab059d7f5ce682/view","enriched":true,"history":[{"index":5,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-31T17:50:15.990Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"8b149d52eb4d4ccfb9ab059d7f5ce682","solicitation_number":"12639526C0042","related_opportunity_id":"875b02884a2d4efcaa95007b349b5192"},{"index":2,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"}]}],"latest_notice_id":"8b149d52eb4d4ccfb9ab059d7f5ce682","first_type":"k","notices":[{"dates":{"posted":"2026-07-16","posted_at":"2026-07-16T18:25:58.399Z","created_at":"2026-07-16T18:16:46.898Z","modified_at":"2026-08-29T05:07:01.482Z","response_deadline":{"raw":"2026-08-14T12:00:00-05:00","utc":"2026-08-14T17:00:00Z","date":"2026-08-14","time":"12:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/75f240da8f1c49dbbb007c0a575e00d2/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Reroute Power Supple at the Phoenix Rearing Facility","agency":{"office":{"code":"1233SL","name":"USDA APHIS"},"subtier":{"code":"12K3","name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"01016","city":"GUATEMALA CITY","country":"GTM"},"organization_id":"100171874","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-29","archive_type":"auto15"},"history":[{"index":4,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":2,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-22T19:27:06.094Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"bbf95338c4544393a4f4d8a1bc7994ad","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":1,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-16T18:25:58.399Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2","solicitation_number":"12639526Q0224"}],"contacts":[{"name":"Erick Plamann","role":"primary","email":"erick.plamann@usda.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"75f240da8f1c49dbbb007c0a575e00d2","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"75f240da8f1c49dbbb007c0a575e00d2","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-29T02:06:05.279683606Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"c331b37884d1bb38bd591fb5876f20ea0ad67c88517c39f4cd578be48f00d373","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-29T02:06:05.279683606Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Reroute Power Supply</p>\n\n<p><br />\nPOC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov</p>\n\n<p><br />\na licensed electrician remove the 2 conduit tripping hazard and reroute the supply&nbsp;power and control wires overhead to the mixing blender. The breaker panel for the&nbsp;240-volt 3 phase supply power is located in the next room where the electrician will<br />\nhave to run new conduit through a wall to the mixing blender. The control wire panel&nbsp;is located within 10 feet from the mixing blender. We prefer that the electrician&nbsp;uses rigid conduit and seals all connections to prevent electrical arching. We do<br />\nhave fine dust particles from wheat and soy which can become highly flammable. The&nbsp;kitchen possesses a dust collecting system which gathers most of the dust particles.</p>\n\n<p><br />\nNAICS Code: 238210</p>\n\n<p><br />\nThis is being solicited 100% Small Business</p>\n\n<p><br />\nMagnitude: Under $25,000</p>\n\n<p></p>\n\n<p>Site Visit<br />\nDate: 23 July 2026<br />\nTime: 10:00 AM<br />\nLocation: 3645 E. Chipman RD, Phoenix AZ 85040<br />\nPOC: Marvin Draper<br />\nPOC Email: marvin.draper@usda.gov</p>\n\n<p>All question must be emailed (no other means will&nbsp;be accepted) to erick.plamann@usda.gov no later&nbsp;than 12:00 PM Central Time on 7/29/0226.</p>\n\n<p><br />\nAll offers must be emailed (no other means will&nbsp;be accepted) to erick.plamann@usda.gov no later&nbsp;than 12:00 PM Central Time on 8/12/0226.</p>\n\n<p></p>","text":"Reroute Power Supply\n\nPOC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov\n\na licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will\n\nhave to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do\n\nhave fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles.\n\nNAICS Code: 238210\n\nThis is being solicited 100% Small Business\n\nMagnitude: Under $25,000\n\nSite Visit\n\nDate: 23 July 2026\n\nTime: 10:00 AM\n\nLocation: 3645 E. Chipman RD, Phoenix AZ 85040\n\nPOC: Marvin Draper\n\nPOC Email: marvin.draper@usda.gov\n\nAll question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226.\n\nAll offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/12/0226.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"12639526Q0224","place_of_performance":{"zip":"85040","city":{"code":"55000","name":"Phoenix"},"state":{"code":"AZ","name":"Arizona"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1AZ"},{"dates":{"posted":"2026-07-22","posted_at":"2026-07-22T19:27:06.094Z","created_at":"2026-07-22T19:19:07.279Z","modified_at":"2026-08-29T05:07:01.482Z","response_deadline":{"raw":"2026-08-14T12:00:00-05:00","utc":"2026-08-14T17:00:00Z","date":"2026-08-14","time":"12:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/bbf95338c4544393a4f4d8a1bc7994ad/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Reroute Power Supple at the Phoenix Rearing Facility","agency":{"office":{"code":"1233SL","name":"USDA APHIS"},"subtier":{"code":"12K3","name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"01016","city":"GUATEMALA CITY","country":"GTM"},"organization_id":"100171874","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-29","archive_type":"auto15"},"history":[{"index":4,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":2,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-22T19:27:06.094Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"bbf95338c4544393a4f4d8a1bc7994ad","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":1,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-16T18:25:58.399Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2","solicitation_number":"12639526Q0224"}],"contacts":[{"name":"Erick Plamann","role":"primary","email":"erick.plamann@usda.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"bbf95338c4544393a4f4d8a1bc7994ad","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"75f240da8f1c49dbbb007c0a575e00d2","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-28T03:02:25.439672730Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"5516b96c3277ea7673407ca4ae5c9b6c2ba601623d92aaadc6bb0f81e68c251f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-28T03:02:25.439672730Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Reroute Power Supply</p>\n\n<p><br />\nPOC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov</p>\n\n<p><br />\na licensed electrician remove the 2 conduit tripping hazard and reroute the supply&nbsp;power and control wires overhead to the mixing blender. The breaker panel for the&nbsp;240-volt 3 phase supply power is located in the next room where the electrician will<br />\nhave to run new conduit through a wall to the mixing blender. The control wire panel&nbsp;is located within 10 feet from the mixing blender. We prefer that the electrician&nbsp;uses rigid conduit and seals all connections to prevent electrical arching. We do<br />\nhave fine dust particles from wheat and soy which can become highly flammable. The&nbsp;kitchen possesses a dust collecting system which gathers most of the dust particles.</p>\n\n<p><br />\nNAICS Code: 238210</p>\n\n<p><br />\nThis is being solicited 100% Small Business</p>\n\n<p><br />\nMagnitude: Under $25,000</p>\n\n<p></p>\n\n<p>Site Visit<br />\nDate: 23 July 2026<br />\nTime: 10:00 AM<br />\nLocation: 3645 E. Chipman RD, Phoenix AZ 85040<br />\nPOC: Marvin Draper<br />\nPOC Email: marvin.draper@usda.gov</p>\n\n<p>All question must be emailed (no other means will&nbsp;be accepted) to erick.plamann@usda.gov no later&nbsp;than 12:00 PM Central Time on 7/29/0226.</p>\n\n<p><br />\nAll offers must be emailed (no other means will&nbsp;be accepted) to erick.plamann@usda.gov no later&nbsp;than 12:00 PM Central Time on 8/14/0226.</p>\n\n<p></p>","text":"Reroute Power Supply\n\nPOC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov\n\na licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will\n\nhave to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do\n\nhave fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles.\n\nNAICS Code: 238210\n\nThis is being solicited 100% Small Business\n\nMagnitude: Under $25,000\n\nSite Visit\n\nDate: 23 July 2026\n\nTime: 10:00 AM\n\nLocation: 3645 E. Chipman RD, Phoenix AZ 85040\n\nPOC: Marvin Draper\n\nPOC Email: marvin.draper@usda.gov\n\nAll question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226.\n\nAll offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/14/0226.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"12639526Q0224","place_of_performance":{"zip":"85040","city":{"code":"55000","name":"Phoenix"},"state":{"code":"AZ","name":"Arizona"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1AZ"},{"dates":{"posted":"2026-08-05","posted_at":"2026-08-05T16:43:51.426Z","created_at":"2026-08-05T16:39:51.100Z","modified_at":"2026-08-29T05:07:01.482Z","response_deadline":{"raw":"2026-08-14T12:00:00-05:00","utc":"2026-08-14T17:00:00Z","date":"2026-08-14","time":"12:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/875b02884a2d4efcaa95007b349b5192/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Reroute Power Supple at the Phoenix Rearing Facility","agency":{"office":{"code":"1233SL","name":"USDA APHIS"},"subtier":{"code":"12K3","name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"01016","city":"GUATEMALA CITY","country":"GTM"},"organization_id":"100171874","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-29","archive_type":"auto15"},"history":[{"index":10,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-31T17:50:15.990Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"8b149d52eb4d4ccfb9ab059d7f5ce682","solicitation_number":"12639526C0042","related_opportunity_id":"875b02884a2d4efcaa95007b349b5192"},{"index":7,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-18T16:35:50.986Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"a26b6f4dc4f14c7380600a16a49e3e17","solicitation_number":"12639526C0042","related_opportunity_id":"875b02884a2d4efcaa95007b349b5192"},{"index":5,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":2,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-22T19:27:06.094Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"bbf95338c4544393a4f4d8a1bc7994ad","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"},{"index":1,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-07-16T18:25:58.399Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2","solicitation_number":"12639526Q0224"}],"contacts":[{"name":"Erick Plamann","role":"primary","email":"erick.plamann@usda.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"875b02884a2d4efcaa95007b349b5192","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"75f240da8f1c49dbbb007c0a575e00d2","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-26T02:40:27.098133989Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"283e9d5d6677be906bdc2e0921e3fbeb7dc8e4dc3dfe62a83d02ffe8c6d8e8fe","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-26T02:40:27.098133989Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"html":"<p>Reroute Power Supply</p>\n\n<p><br />\nPOC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov</p>\n\n<p><br />\na licensed electrician remove the 2 conduit tripping hazard and reroute the supply&nbsp;power and control wires overhead to the mixing blender. The breaker panel for the&nbsp;240-volt 3 phase supply power is located in the next room where the electrician will<br />\nhave to run new conduit through a wall to the mixing blender. The control wire panel&nbsp;is located within 10 feet from the mixing blender. We prefer that the electrician&nbsp;uses rigid conduit and seals all connections to prevent electrical arching. We do<br />\nhave fine dust particles from wheat and soy which can become highly flammable. The&nbsp;kitchen possesses a dust collecting system which gathers most of the dust particles.</p>\n\n<p><br />\nNAICS Code: 238210</p>\n\n<p><br />\nThis is being solicited 100% Small Business</p>\n\n<p><br />\nMagnitude: Under $25,000</p>\n\n<p></p>\n\n<p>Site Visit<br />\nDate: 23 July 2026<br />\nTime: 10:00 AM<br />\nLocation: 3645 E. Chipman RD, Phoenix AZ 85040<br />\nPOC: Marvin Draper<br />\nPOC Email: marvin.draper@usda.gov</p>\n\n<p>All question must be emailed (no other means will&nbsp;be accepted) to erick.plamann@usda.gov no later&nbsp;than 12:00 PM Central Time on 7/29/0226.</p>\n\n<p><br />\nAll offers must be emailed (no other means will&nbsp;be accepted) to erick.plamann@usda.gov no later&nbsp;than 12:00 PM Central Time on 8/14/0226.</p>\n\n<p></p>","text":"Reroute Power Supply\n\nPOC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov\n\na licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will\n\nhave to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do\n\nhave fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles.\n\nNAICS Code: 238210\n\nThis is being solicited 100% Small Business\n\nMagnitude: Under $25,000\n\nSite Visit\n\nDate: 23 July 2026\n\nTime: 10:00 AM\n\nLocation: 3645 E. Chipman RD, Phoenix AZ 85040\n\nPOC: Marvin Draper\n\nPOC Email: marvin.draper@usda.gov\n\nAll question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226.\n\nAll offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/14/0226.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"12639526Q0224","place_of_performance":{"zip":"85040","city":{"code":"55000","name":"Phoenix"},"state":{"code":"AZ","name":"Arizona"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1AZ"},{"award":{"date":"2026-08-14","amount":"15971.00","number":"12639526C0042","awardee":{"raw":"New Phase Electrical LLC Wickenburg AZ 85390 USA","uei":"G4GYJLE625L5","cage":"9S7Y8","name":"New Phase Electrical LLC","location":{"zip":"85390","city":{"code":"82740","name":"Wickenburg"},"state":{"code":"AZ","name":"Arizona"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-08-18","posted_at":"2026-08-18T16:35:50.986Z","award_date":"2026-08-14","created_at":"2026-08-18T16:32:41.109Z","modified_at":"2026-08-29T05:07:01.482Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/a26b6f4dc4f14c7380600a16a49e3e17/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Reroute Power Supple at the Phoenix Rearing Facility","agency":{"office":{"code":"1233SL","name":"USDA APHIS"},"subtier":{"code":"12K3","name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"01016","city":"GUATEMALA CITY","country":"GTM"},"organization_id":"100171874","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-29","archive_type":"auto15"},"history":[{"index":5,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-18T16:35:50.986Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"a26b6f4dc4f14c7380600a16a49e3e17","solicitation_number":"12639526C0042","related_opportunity_id":"875b02884a2d4efcaa95007b349b5192"},{"index":3,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"}],"contacts":[{"name":"Erick Plamann","role":"primary","email":"erick.plamann@usda.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"a26b6f4dc4f14c7380600a16a49e3e17","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"75f240da8f1c49dbbb007c0a575e00d2","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T15:07:27.631006311Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"47664ffc5549ccf31877bf0b43ff0512ca0a342f85a2314adf0484ab3832b33d","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-24T15:07:27.631006311Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"12639526C0042","place_of_performance":{"zip":"85040","city":{"code":"55000","name":"Phoenix"},"state":{"code":"AZ","name":"Arizona"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1AZ"},{"award":{"date":"2026-07-16","amount":"15971.00","number":"12639526C0042","awardee":{"raw":"New Phase Electrical LLC Wickenburg AZ 85390 USA","uei":"G4GYJLE625L5","cage":"9S7Y8","name":"New Phase Electrical LLC","location":{"zip":"85390","city":{"code":"82740","name":"Wickenburg"},"state":{"code":"AZ","name":"Arizona"},"country":{"code":"USA","name":"UNITED STATES"}}}},"dates":{"posted":"2026-08-31","posted_at":"2026-08-31T17:50:15.990Z","award_date":"2026-07-16","created_at":"2026-08-31T17:47:24.431Z","modified_at":"2026-09-01T05:06:55.494Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/8b149d52eb4d4ccfb9ab059d7f5ce682/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Reroute Power Supple at the Phoenix Rearing Facility","agency":{"office":{"code":"1233SL","name":"USDA APHIS"},"subtier":{"code":"12K3","name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"01016","city":"GUATEMALA CITY","country":"GTM"},"organization_id":"100171874","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-08-31","archive_type":"auto_custom"},"history":[{"index":5,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-31T17:50:15.990Z","notice_type":{"code":"a","label":"Award Notice"},"request_type":"submit","opportunity_id":"8b149d52eb4d4ccfb9ab059d7f5ce682","solicitation_number":"12639526C0042","related_opportunity_id":"875b02884a2d4efcaa95007b349b5192"},{"index":2,"title":"Reroute Power Supple at the Phoenix Rearing Facility","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-05T16:43:51.426Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"875b02884a2d4efcaa95007b349b5192","solicitation_number":"12639526Q0224","parent_opportunity_id":"75f240da8f1c49dbbb007c0a575e00d2"}],"contacts":[{"name":"Erick Plamann","role":"primary","email":"erick.plamann@usda.gov"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"8b149d52eb4d4ccfb9ab059d7f5ce682","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"75f240da8f1c49dbbb007c0a575e00d2","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-24T06:50:14.631575467Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"0eb60c8bff4bc8e1f9b9527a53250db820e99f5decf7528946df64b4e65ec010","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-24T06:50:14.631575467Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"12639526C0042","place_of_performance":{"zip":"85040","city":{"code":"55000","name":"Phoenix"},"state":{"code":"AZ","name":"Arizona"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Y1AZ"}],"due_at":"2026-08-14T17:00:00Z","due_date":"2026-08-14","closes_at":"2026-08-14T17:00:00Z","awardable":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12K3","sub_name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE","office_key":"o-1233SL","office_name":"USDA APHIS","state":"AZ","county":"04013","county_name":"Maricopa County","city":"0455000","city_name":"Phoenix","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"G4GYJLE625L5","amount":"15971.00","linked_awards":5,"cancelled":false,"archived":true,"updated_at":"2026-09-24T07:03:51.210646Z","principal_notice_id":"875b02884a2d4efcaa95007b349b5192","description":{"text":"Reroute Power Supply\n\nPOC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov\n\na licensed electrician remove the 2 conduit tripping hazard and reroute the supply power and control wires overhead to the mixing blender. The breaker panel for the 240-volt 3 phase supply power is located in the next room where the electrician will\n\nhave to run new conduit through a wall to the mixing blender. The control wire panel is located within 10 feet from the mixing blender. We prefer that the electrician uses rigid conduit and seals all connections to prevent electrical arching. We do\n\nhave fine dust particles from wheat and soy which can become highly flammable. The kitchen possesses a dust collecting system which gathers most of the dust particles.\n\nNAICS Code: 238210\n\nThis is being solicited 100% Small Business\n\nMagnitude: Under $25,000\n\nSite Visit\n\nDate: 23 July 2026\n\nTime: 10:00 AM\n\nLocation: 3645 E. Chipman RD, Phoenix AZ 85040\n\nPOC: Marvin Draper\n\nPOC Email: marvin.draper@usda.gov\n\nAll question must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 7/29/0226.\n\nAll offers must be emailed (no other means will be accepted) to erick.plamann@usda.gov no later than 12:00 PM Central Time on 8/14/0226.","html":"<p>Reroute Power Supply</p>\n\n<p><br />\nPOC: Erick Plamann, Contract Specialist, erick.plamann@usda.gov</p>\n\n<p><br />\na licensed electrician remove the 2 conduit tripping hazard and reroute the supply&nbsp;power and control wires overhead to the mixing blender. The breaker panel for the&nbsp;240-volt 3 phase supply power is located in the next room where the electrician will<br />\nhave to run new conduit through a wall to the mixing blender. The control wire panel&nbsp;is located within 10 feet from the mixing blender. We prefer that the electrician&nbsp;uses rigid conduit and seals all connections to prevent electrical arching. We do<br />\nhave fine dust particles from wheat and soy which can become highly flammable. The&nbsp;kitchen possesses a dust collecting system which gathers most of the dust particles.</p>\n\n<p><br />\nNAICS Code: 238210</p>\n\n<p><br />\nThis is being solicited 100% Small Business</p>\n\n<p><br />\nMagnitude: Under $25,000</p>\n\n<p></p>\n\n<p>Site Visit<br />\nDate: 23 July 2026<br />\nTime: 10:00 AM<br />\nLocation: 3645 E. Chipman RD, Phoenix AZ 85040<br />\nPOC: Marvin Draper<br />\nPOC Email: marvin.draper@usda.gov</p>\n\n<p>All question must be emailed (no other means will&nbsp;be accepted) to erick.plamann@usda.gov no later&nbsp;than 12:00 PM Central Time on 7/29/0226.</p>\n\n<p><br />\nAll offers must be emailed (no other means will&nbsp;be accepted) to erick.plamann@usda.gov no later&nbsp;than 12:00 PM Central Time on 8/14/0226.</p>\n\n<p></p>","origin":"detail"},"contacts":[{"name":"Erick Plamann","role":"primary","email":"erick.plamann@usda.gov"}],"place_of_performance":{"zip":"85040","city":{"code":"55000","name":"Phoenix"},"state":{"code":"AZ","name":"Arizona"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"01016","city":"GUATEMALA CITY","country":"GTM"},"naics_codes":["238210"],"award":null,"attachments":[{"resource_id":"33b81cb7ef38499099a1afa3d4107b63","name":"C04_Attachment 1 SOI.pdf","kind":"file","mime_type":".pdf","size_bytes":54273,"posted_at":"2026-07-16T18:25:58.399Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/33b81cb7ef38499099a1afa3d4107b63/download","mirrored":false},{"resource_id":"3bc010c79b314b69b047667b86a2786b","name":"C04_Attachment 3 Wage Determination.pdf","kind":"file","mime_type":".pdf","size_bytes":153246,"posted_at":"2026-07-16T18:25:58.399Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/3bc010c79b314b69b047667b86a2786b/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_12639526C0042_12K3_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_12639526C0042_12K3_-NONE-_-NONE-/","piid":"12639526C0042","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"G4GYJLE625L5","recipient_name":"NEW PHASE ELECTRICAL LLC","recipient_uei":"G4GYJLE625L5","recipient_cage":"9S7Y8","recipient_city":"WICKENBURG","recipient_state":"AZ","sub_name":"Animal and Plant Health Inspection Service","office_name":"MRPBS MINNEAPOLIS MN","office_key":"o-126395","first_action_date":"2026-08-13","last_action_date":"2026-08-13","actions":1,"obligated":"15971.00","current_total_value":"15971.00","potential_total_value":"15971.00","naics":"238210","psc":"Y1AZ","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":2,"description":"REROUTE POWER SUPPLY IN KITCHEN - REROUTE 2\" CONDUIT THAT IS CAUSING A MAJOR TRIPPING HAZARD.","method":"solicitation","confidence":"high","evidence":["solicitation number 12639526Q0224 equals the FPDS solicitation identifier","same sub-agency 12K3"],"opportunity_key":null,"opportunity_title":null}],"related":[],"similar_open":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"127EAW27Q0002","latest_notice_id":"59c24c6aad3541448f35b465324ba88b","title":"Forest Service - Solar Batteries Frenchman Work Center","solicitation_number":"127EAW27Q0002","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-28T00:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-127EAW","office_name":"USDA-FS, CSA SOUTHWEST 6","naics":"238210","psc":"N061","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"FA706027R0001","latest_notice_id":"541189d6ec7b40e2b7a0dcf9030d56ec","title":"Request for Information/Market Intelligence Notice: Repair Electrical Distribution System Switchgear Stations & Addition of Redundancy Cable Use of Progressive Design Build (PDB) with Other Transaction Authority (OTA)","solicitation_number":"FA706027R0001","notice_type":"r","first_type":"r","first_posted":"2026-10-23","last_posted":"2026-10-23","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA7060","office_name":"FA7060 11TH CONTRACTING SQ PK","naics":"238210","psc":"Z2JZ","set_aside":null,"state":"DC","county":"11001","county_name":"District of Columbia","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-24T03:56:54.139438Z"}],"similar_open_total":40,"indexable":false}