{"canonical":"https://sealedbidder.com/opportunities/12639526q0074","key":"12639526Q0074","url":"https://sealedbidder.com/opportunities/12639526q0074","title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","solicitation_number":"12639526Q0074","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-04-23T22:00:00Z","first_posted":"2026-03-17","last_posted":"2026-04-17","department":"AGRICULTURE, DEPARTMENT OF","subagency":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE","office":"MRPBS MINNEAPOLIS MN","naics":"238210","psc":"J059","set_aside":"SBA","place_state":"HI","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"15003","place_county_name":"Honolulu County","place_city":"1571550","place_city_name":"Urban Honolulu","winner":"LENA EYES LLC","award_amount":null,"publications":[{"notice_id":"f69cb8762ed240faba1fa99a4868a935","title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","solicitation_number":"12639526Q0074","notice_type":"k","base_type":"k","posted":"2026-03-17","posted_at":"2026-03-17T14:30:17.428Z","due_at":"2026-04-16T22:00:00Z","due_date":"2026-04-16","cancelled":false,"archived":true,"archive_date":"2026-05-01","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f69cb8762ed240faba1fa99a4868a935/view","enriched":true,"history":[{"index":3,"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-17T17:17:39.070Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"b6221c3fa8cb47848f5212677429e0ac","solicitation_number":"12639526Q0074","parent_opportunity_id":"f69cb8762ed240faba1fa99a4868a935"},{"index":1,"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-17T14:30:17.428Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"f69cb8762ed240faba1fa99a4868a935","solicitation_number":"12639526Q0074"}]},{"notice_id":"b6221c3fa8cb47848f5212677429e0ac","title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","solicitation_number":"12639526Q0074","notice_type":"k","base_type":"k","posted":"2026-04-17","posted_at":"2026-04-17T17:17:39.070Z","due_at":"2026-04-23T22:00:00Z","due_date":"2026-04-23","cancelled":false,"archived":true,"archive_date":"2026-05-08","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b6221c3fa8cb47848f5212677429e0ac/view","enriched":true,"history":[{"index":3,"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-17T17:17:39.070Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"b6221c3fa8cb47848f5212677429e0ac","solicitation_number":"12639526Q0074","parent_opportunity_id":"f69cb8762ed240faba1fa99a4868a935"},{"index":1,"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-17T14:30:17.428Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"f69cb8762ed240faba1fa99a4868a935","solicitation_number":"12639526Q0074"}]}],"latest_notice_id":"b6221c3fa8cb47848f5212677429e0ac","first_type":"k","notices":[{"dates":{"posted":"2026-03-17","posted_at":"2026-03-17T14:30:17.428Z","created_at":"2026-03-16T19:18:53.681Z","modified_at":"2026-05-09T04:06:38.805Z","response_deadline":{"raw":"2026-04-16T12:00:00-10:00","utc":"2026-04-16T22:00:00Z","date":"2026-04-16","time":"12:00:00","timezone":"Pacific/Honolulu","utc_offset_seconds":-36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f69cb8762ed240faba1fa99a4868a935/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","agency":{"office":{"code":"126395","name":"MRPBS MINNEAPOLIS MN"},"subtier":{"code":"12K3","name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"55401","city":"MINNEAPOLIS","state":"MN","country":"USA"},"organization_id":"500025532","organization_type":"OFFICE"},"status":{"active":false,"latest":false,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-01","archive_type":"auto15"},"history":[{"index":3,"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-17T17:17:39.070Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"b6221c3fa8cb47848f5212677429e0ac","solicitation_number":"12639526Q0074","parent_opportunity_id":"f69cb8762ed240faba1fa99a4868a935"},{"index":1,"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-17T14:30:17.428Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"f69cb8762ed240faba1fa99a4868a935","solicitation_number":"12639526Q0074"}],"contacts":[{"name":"Samuel Lopez","role":"primary","email":"samuel.lopez@usda.gov","phone":"(970) 896-3437"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"f69cb8762ed240faba1fa99a4868a935","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"f69cb8762ed240faba1fa99a4868a935","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-11T02:48:42.569370452Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"3ded0ea2cbefb332624614dbc6d02c8c45f3c18cc492e76eff96740b97a6d012","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-11T02:48:42.569370452Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The USDA Medfly Preventative Release Program requires the complete removal and disposal of the existing backup generator (C100D6C Diesel Genset, 60Hz, 100kW) and Automatic Transfer Switch (ATS) (CBLC, Bypass Transfer Switch‑Power Command: 150A/225A/260/300/400/600A), along with the removal and disposal of the associated diesel fuel tank, diesel fuel, and concrete equipment pad. This requirement includes furnishing and installing a new diesel‑powered backup generator, a new Automatic Transfer Switch (ATS), a new diesel fuel tank with fuel, and a new concrete pad, as well as all items required to completely install, test, and commission the equipment in accordance with the Statement of Work.</p>\n\n<p>The new generator must provide a minimum standby capacity of 100 kW, equal to the existing system. Generators with capacities greater than 100 kW are acceptable and may be proposed, provided they meet all compatibility, site, electrical, and operational requirements outlined in the Statement of Work.</p>\n\n<p>Work includes, but is not limited to:<br />\n&bull; Decommissioning, removal, and proper disposal of the existing generator system, ATS, diesel fuel tank, diesel fuel, and concrete pad;<br />\n&bull; Furnishing and installing a new generator, ATS, diesel fuel tank, and new concrete pad;<br />\n&bull; All mechanical, electrical, piping, exhaust, grounding, controls, and associated work required for a complete and functional system;<br />\n&bull; Supplying up to 550 gallons of new diesel fuel for startup, testing, and commissioning;<br />\n&bull; Startup, testing, and commissioning of the new system; and<br />\n&bull; Providing all submittals, shop drawings, manuals, warranties, as‑builts, and required training;</p>\n\n<p>The solicitation documents are posted below.</p>","text":"The USDA Medfly Preventative Release Program requires the complete removal and disposal of the existing backup generator (C100D6C Diesel Genset, 60Hz, 100kW) and Automatic Transfer Switch (ATS) (CBLC, Bypass Transfer Switch‑Power Command: 150A/225A/260/300/400/600A), along with the removal and disposal of the associated diesel fuel tank, diesel fuel, and concrete equipment pad. This requirement includes furnishing and installing a new diesel‑powered backup generator, a new Automatic Transfer Switch (ATS), a new diesel fuel tank with fuel, and a new concrete pad, as well as all items required to completely install, test, and commission the equipment in accordance with the Statement of Work.\n\nThe new generator must provide a minimum standby capacity of 100 kW, equal to the existing system. Generators with capacities greater than 100 kW are acceptable and may be proposed, provided they meet all compatibility, site, electrical, and operational requirements outlined in the Statement of Work.\n\nWork includes, but is not limited to:\n\n• Decommissioning, removal, and proper disposal of the existing generator system, ATS, diesel fuel tank, diesel fuel, and concrete pad;\n\n• Furnishing and installing a new generator, ATS, diesel fuel tank, and new concrete pad;\n\n• All mechanical, electrical, piping, exhaust, grounding, controls, and associated work required for a complete and functional system;\n\n• Supplying up to 550 gallons of new diesel fuel for startup, testing, and commissioning;\n\n• Startup, testing, and commissioning of the new system; and\n\n• Providing all submittals, shop drawings, manuals, warranties, as‑builts, and required training;\n\nThe solicitation documents are posted below.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"12639526Q0074","place_of_performance":{"zip":"96822","city":{"code":"16999","name":"Honolulu"},"state":{"code":"HI","name":"Hawaii"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J059"},{"dates":{"posted":"2026-04-17","posted_at":"2026-04-17T17:17:39.070Z","created_at":"2026-04-10T17:13:37.552Z","modified_at":"2026-05-09T04:06:38.805Z","response_deadline":{"raw":"2026-04-23T12:00:00-10:00","utc":"2026-04-23T22:00:00Z","date":"2026-04-23","time":"12:00:00","timezone":"Pacific/Honolulu","utc_offset_seconds":-36000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b6221c3fa8cb47848f5212677429e0ac/view"},"naics":{"codes":["238210"],"primary":"238210"},"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","agency":{"office":{"code":"126395","name":"MRPBS MINNEAPOLIS MN"},"subtier":{"code":"12K3","name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"55401","city":"MINNEAPOLIS","state":"MN","country":"USA"},"organization_id":"500025532","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-05-08","archive_type":"auto15"},"history":[{"index":3,"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-04-17T17:17:39.070Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"b6221c3fa8cb47848f5212677429e0ac","solicitation_number":"12639526Q0074","parent_opportunity_id":"f69cb8762ed240faba1fa99a4868a935"},{"index":1,"title":"Replacement of Backup Generator, Fuel Tank, and Automatic Transfer Switch","action":"publish","latest":false,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-03-17T14:30:17.428Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"f69cb8762ed240faba1fa99a4868a935","solicitation_number":"12639526Q0074"}],"contacts":[{"name":"Samuel Lopez","role":"primary","email":"samuel.lopez@usda.gov","phone":"(970) 896-3437"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"b6221c3fa8cb47848f5212677429e0ac","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"f69cb8762ed240faba1fa99a4868a935","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-06T10:39:23.182940869Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"9806d1ac84be39bfd359cd6e5f42002094c95debc24f106fc6199743693a9828","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-10-06T10:39:23.182940869Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"html":"<p>The USDA Medfly Preventative Release Program requires the complete removal and disposal of the existing backup generator (C100D6C Diesel Genset, 60Hz, 100kW) and Automatic Transfer Switch (ATS) (CBLC, Bypass Transfer Switch‑Power Command: 150A/225A/260/300/400/600A), along with the removal and disposal of the associated diesel fuel tank, diesel fuel, and concrete equipment pad. This requirement includes furnishing and installing a new diesel‑powered backup generator, a new Automatic Transfer Switch (ATS), a new diesel fuel tank with fuel, and a new concrete pad, as well as all items required to completely install, test, and commission the equipment in accordance with the Statement of Work.</p>\n\n<p>The new generator must provide a minimum standby capacity of 100 kW, equal to the existing system. Generators with capacities greater than 100 kW are acceptable and may be proposed, provided they meet all compatibility, site, electrical, and operational requirements outlined in the Statement of Work.</p>\n\n<p>Work includes, but is not limited to:<br />\n&bull; Decommissioning, removal, and proper disposal of the existing generator system, ATS, diesel fuel tank, diesel fuel, and concrete pad;<br />\n&bull; Furnishing and installing a new generator, ATS, diesel fuel tank, and new concrete pad;<br />\n&bull; All mechanical, electrical, piping, exhaust, grounding, controls, and associated work required for a complete and functional system;<br />\n&bull; Supplying up to 550 gallons of new diesel fuel for startup, testing, and commissioning;<br />\n&bull; Startup, testing, and commissioning of the new system; and<br />\n&bull; Providing all submittals, shop drawings, manuals, warranties, as‑builts, and required training;</p>\n\n<p>The solicitation documents are posted below.</p>\n\n<p>RFIs and responses are posted below.</p>","text":"The USDA Medfly Preventative Release Program requires the complete removal and disposal of the existing backup generator (C100D6C Diesel Genset, 60Hz, 100kW) and Automatic Transfer Switch (ATS) (CBLC, Bypass Transfer Switch‑Power Command: 150A/225A/260/300/400/600A), along with the removal and disposal of the associated diesel fuel tank, diesel fuel, and concrete equipment pad. This requirement includes furnishing and installing a new diesel‑powered backup generator, a new Automatic Transfer Switch (ATS), a new diesel fuel tank with fuel, and a new concrete pad, as well as all items required to completely install, test, and commission the equipment in accordance with the Statement of Work.\n\nThe new generator must provide a minimum standby capacity of 100 kW, equal to the existing system. Generators with capacities greater than 100 kW are acceptable and may be proposed, provided they meet all compatibility, site, electrical, and operational requirements outlined in the Statement of Work.\n\nWork includes, but is not limited to:\n\n• Decommissioning, removal, and proper disposal of the existing generator system, ATS, diesel fuel tank, diesel fuel, and concrete pad;\n\n• Furnishing and installing a new generator, ATS, diesel fuel tank, and new concrete pad;\n\n• All mechanical, electrical, piping, exhaust, grounding, controls, and associated work required for a complete and functional system;\n\n• Supplying up to 550 gallons of new diesel fuel for startup, testing, and commissioning;\n\n• Startup, testing, and commissioning of the new system; and\n\n• Providing all submittals, shop drawings, manuals, warranties, as‑builts, and required training;\n\nThe solicitation documents are posted below.\n\nRFIs and responses are posted below.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"12639526Q0074","place_of_performance":{"zip":"96822","city":{"code":"16999","name":"Honolulu"},"state":{"code":"HI","name":"Hawaii"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J059"}],"due_at":"2026-04-23T22:00:00Z","due_date":"2026-04-23","closes_at":"2026-04-23T22:00:00Z","awardable":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12K3","sub_name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE","office_key":"o-126395","office_name":"MRPBS MINNEAPOLIS MN","state":"HI","county":"15003","county_name":"Honolulu County","city":"1571550","city_name":"Urban Honolulu","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"CY6EECZUH2B5","amount":null,"linked_awards":2,"cancelled":false,"archived":true,"updated_at":"2026-10-06T11:17:55.120446Z","principal_notice_id":"b6221c3fa8cb47848f5212677429e0ac","description":{"text":"The USDA Medfly Preventative Release Program requires the complete removal and disposal of the existing backup generator (C100D6C Diesel Genset, 60Hz, 100kW) and Automatic Transfer Switch (ATS) (CBLC, Bypass Transfer Switch‑Power Command: 150A/225A/260/300/400/600A), along with the removal and disposal of the associated diesel fuel tank, diesel fuel, and concrete equipment pad. This requirement includes furnishing and installing a new diesel‑powered backup generator, a new Automatic Transfer Switch (ATS), a new diesel fuel tank with fuel, and a new concrete pad, as well as all items required to completely install, test, and commission the equipment in accordance with the Statement of Work.\n\nThe new generator must provide a minimum standby capacity of 100 kW, equal to the existing system. Generators with capacities greater than 100 kW are acceptable and may be proposed, provided they meet all compatibility, site, electrical, and operational requirements outlined in the Statement of Work.\n\nWork includes, but is not limited to:\n\n• Decommissioning, removal, and proper disposal of the existing generator system, ATS, diesel fuel tank, diesel fuel, and concrete pad;\n\n• Furnishing and installing a new generator, ATS, diesel fuel tank, and new concrete pad;\n\n• All mechanical, electrical, piping, exhaust, grounding, controls, and associated work required for a complete and functional system;\n\n• Supplying up to 550 gallons of new diesel fuel for startup, testing, and commissioning;\n\n• Startup, testing, and commissioning of the new system; and\n\n• Providing all submittals, shop drawings, manuals, warranties, as‑builts, and required training;\n\nThe solicitation documents are posted below.\n\nRFIs and responses are posted below.","html":"<p>The USDA Medfly Preventative Release Program requires the complete removal and disposal of the existing backup generator (C100D6C Diesel Genset, 60Hz, 100kW) and Automatic Transfer Switch (ATS) (CBLC, Bypass Transfer Switch‑Power Command: 150A/225A/260/300/400/600A), along with the removal and disposal of the associated diesel fuel tank, diesel fuel, and concrete equipment pad. This requirement includes furnishing and installing a new diesel‑powered backup generator, a new Automatic Transfer Switch (ATS), a new diesel fuel tank with fuel, and a new concrete pad, as well as all items required to completely install, test, and commission the equipment in accordance with the Statement of Work.</p>\n\n<p>The new generator must provide a minimum standby capacity of 100 kW, equal to the existing system. Generators with capacities greater than 100 kW are acceptable and may be proposed, provided they meet all compatibility, site, electrical, and operational requirements outlined in the Statement of Work.</p>\n\n<p>Work includes, but is not limited to:<br />\n&bull; Decommissioning, removal, and proper disposal of the existing generator system, ATS, diesel fuel tank, diesel fuel, and concrete pad;<br />\n&bull; Furnishing and installing a new generator, ATS, diesel fuel tank, and new concrete pad;<br />\n&bull; All mechanical, electrical, piping, exhaust, grounding, controls, and associated work required for a complete and functional system;<br />\n&bull; Supplying up to 550 gallons of new diesel fuel for startup, testing, and commissioning;<br />\n&bull; Startup, testing, and commissioning of the new system; and<br />\n&bull; Providing all submittals, shop drawings, manuals, warranties, as‑builts, and required training;</p>\n\n<p>The solicitation documents are posted below.</p>\n\n<p>RFIs and responses are posted below.</p>","origin":"detail"},"contacts":[{"name":"Samuel Lopez","role":"primary","email":"samuel.lopez@usda.gov","phone":"(970) 896-3437"}],"place_of_performance":{"zip":"96822","city":{"code":"16999","name":"Honolulu"},"state":{"code":"HI","name":"Hawaii"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"55401","city":"MINNEAPOLIS","state":"MN","country":"USA"},"naics_codes":["238210"],"award":null,"attachments":[{"resource_id":"9072bd1924e049b2978816b91ba33334","name":"Attachment_2_Federal_Construction_Wage_Rates_WD_HI20260001_Modification_01.pdf","kind":"file","mime_type":".pdf","size_bytes":8278439,"posted_at":"2026-03-17T14:30:17.428Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9072bd1924e049b2978816b91ba33334/download","mirrored":false}],"awards":[{"award_key":"CONT_AWD_12639526P0199_12K3_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_12639526P0199_12K3_-NONE-_-NONE-/","piid":"12639526P0199","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"CY6EECZUH2B5","recipient_name":"LENA EYES LLC","recipient_uei":"CY6EECZUH2B5","recipient_cage":"9YE23","recipient_city":"RICHARDSON","recipient_state":"TX","sub_name":"Animal and Plant Health Inspection Service","office_name":"MRPBS MINNEAPOLIS MN","office_key":"o-126395","first_action_date":"2026-07-22","last_action_date":"2026-07-22","actions":1,"obligated":"216750.00","current_total_value":"216750.00","potential_total_value":"216750.00","naics":"238210","psc":"J059","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":20,"description":"GENERATOR AND ATS","method":"solicitation","confidence":"high","evidence":["solicitation number 12639526Q0074 equals the FPDS solicitation identifier","same awarding office 126395"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"57639526020","latest_notice_id":"5ce101a23750459fb866d4d26b1af055","title":"USDA seeking 6,840 - 7,200 ABOA SF of Hangar, in West Columbia, SC","solicitation_number":"57-6395-26-020","notice_type":"p","first_type":"p","first_posted":"2026-11-25","last_posted":"2026-11-25","notices":1,"due_at":"2026-12-07T14:00:00Z","due_date":"2026-12-07","closes_at":"2026-12-07T14:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12K3","sub_name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE","office_key":"o-126395","office_name":"MRPBS MINNEAPOLIS MN","naics":"531120","psc":"X1BZ","set_aside":null,"state":"SC","county":"45063","county_name":"Lexington County","city":"4575850","city_name":"West Columbia","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-26T04:43:42.403930Z"},{"key":"124PSA27Q0037","latest_notice_id":"d3139a691242433ea9e1d4bc6d7af822","title":"Janitorial Services for Edinburg, TX","solicitation_number":"124PSA27Q0037","notice_type":"k","first_type":"k","first_posted":"2026-11-16","last_posted":"2026-11-24","notices":2,"due_at":"2026-12-14T17:00:00Z","due_date":"2026-12-14","closes_at":"2026-12-14T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12K3","sub_name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE","office_key":"o-126395","office_name":"MRPBS MINNEAPOLIS MN","naics":"561720","psc":"S201","set_aside":null,"state":"TX","county":"48215","county_name":"Hidalgo County","city":"4822660","city_name":"Edinburg","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"12639526Q0089","latest_notice_id":"ce1ca1ed7a0d442eaf7fb64fdc64abde","title":"NAHLN Diagnostic Testing Services","solicitation_number":"12639526Q0089","notice_type":"k","first_type":"k","first_posted":"2026-06-17","last_posted":"2026-07-16","notices":3,"due_at":"2027-06-16T22:00:00Z","due_date":"2027-06-16","closes_at":"2027-06-16T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12K3","sub_name":"ANIMAL AND PLANT HEALTH INSPECTION SERVICE","office_key":"o-126395","office_name":"MRPBS MINNEAPOLIS MN","naics":"541940","psc":"Q301","set_aside":null,"state":"IA","county":"19169","county_name":"Story County","city":"1901855","city_name":"Ames","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-09-24T03:25:58.922164Z"}],"similar_open":[{"key":"36C25027Q0014","latest_notice_id":"b13cc87179e947e7b42da2de44a6bde1","title":"J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland","solicitation_number":"36C25027Q0014","notice_type":"k","first_type":"k","first_posted":"2026-10-09","last_posted":"2026-11-24","notices":5,"due_at":"2026-11-27T20:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-27T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C250","office_name":"250-NETWORK CONTRACT OFFICE 10 (36C250)","naics":"238210","psc":"J061","set_aside":"SBA","state":"OH","county":"39035","county_name":"Cuyahoga County","city":"3916000","city_name":"Cleveland","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"127EAW27Q0002","latest_notice_id":"59c24c6aad3541448f35b465324ba88b","title":"Forest Service - Solar Batteries Frenchman Work Center","solicitation_number":"127EAW27Q0002","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-17","notices":3,"due_at":"2026-11-28T00:00:00Z","due_date":"2026-11-27","closes_at":"2026-11-28T00:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-127EAW","office_name":"USDA-FS, CSA SOUTHWEST 6","naics":"238210","psc":"N061","set_aside":"SBA","state":"CA","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-18T05:19:57.406887Z"},{"key":"FA706027R0001","latest_notice_id":"541189d6ec7b40e2b7a0dcf9030d56ec","title":"Request for Information/Market Intelligence Notice: Repair Electrical Distribution System Switchgear Stations & Addition of Redundancy Cable Use of Progressive Design Build (PDB) with Other Transaction Authority (OTA)","solicitation_number":"FA706027R0001","notice_type":"r","first_type":"r","first_posted":"2026-10-23","last_posted":"2026-10-23","notices":1,"due_at":"2026-11-30T15:00:00Z","due_date":"2026-11-30","closes_at":"2026-11-30T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA7060","office_name":"FA7060 11TH CONTRACTING SQ PK","naics":"238210","psc":"Z2JZ","set_aside":null,"state":"DC","county":"11001","county_name":"District of Columbia","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-24T03:56:54.139438Z"}],"similar_open_total":40,"indexable":false}