{"canonical":"https://sealedbidder.com/opportunities/1240lr27q0002","key":"1240LR27Q0002","url":"https://sealedbidder.com/opportunities/1240lr27q0002","title":"ANF Duchesne Bunkhouse AC Replacement","solicitation_number":"1240LR27Q0002","notice_type":"k","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-11-20T22:00:00Z","first_posted":"2026-10-29","last_posted":"2026-11-10","department":"AGRICULTURE, DEPARTMENT OF","subagency":"FOREST SERVICE","office":"USDA-FS, CSA INTERMOUNTAIN 6","naics":"238220","psc":"J041","set_aside":"SBA","place_state":"UT","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"49047","place_county_name":"Uintah County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"9158d089bdb743b48614818d02d651ad","title":"ANF Duchesne Bunkhouse AC Replacement","solicitation_number":"1240LR27Q0002","notice_type":"k","base_type":"k","posted":"2026-10-29","posted_at":"2026-10-29T22:14:59.245Z","due_at":"2026-11-13T22:00:00Z","due_date":"2026-11-13","cancelled":false,"archived":false,"archive_date":"2026-11-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9158d089bdb743b48614818d02d651ad/view","enriched":true,"history":[{"index":1,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:14:59.245Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9158d089bdb743b48614818d02d651ad","solicitation_number":"1240LR27Q0002"}]},{"notice_id":"23694fe3f487435eb9f4ba29fd4ca8cc","title":"ANF Duchesne Bunkhouse AC Replacement","solicitation_number":"1240LR27Q0002","notice_type":"k","base_type":"k","posted":"2026-11-03","posted_at":"2026-11-03T22:23:52.425Z","due_at":"2026-11-13T22:00:00Z","due_date":"2026-11-13","cancelled":false,"archived":false,"archive_date":"2026-11-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/23694fe3f487435eb9f4ba29fd4ca8cc/view","enriched":true,"history":[{"index":4,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:22:33.936Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f4f30b194c4647159c676c5005dfba09","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":3,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:19:38.881Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c1e3f30708f747a886893171015df7ae","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":2,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T22:23:52.425Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"23694fe3f487435eb9f4ba29fd4ca8cc","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":1,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:14:59.245Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9158d089bdb743b48614818d02d651ad","solicitation_number":"1240LR27Q0002"}]},{"notice_id":"c1e3f30708f747a886893171015df7ae","title":"ANF Duchesne Bunkhouse AC Replacement","solicitation_number":"1240LR27Q0002","notice_type":"k","base_type":"k","posted":"2026-11-10","posted_at":"2026-11-11T00:19:38.881Z","due_at":"2026-11-20T22:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c1e3f30708f747a886893171015df7ae/view","enriched":true,"history":[{"index":4,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:22:33.936Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f4f30b194c4647159c676c5005dfba09","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":3,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:19:38.881Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c1e3f30708f747a886893171015df7ae","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":2,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T22:23:52.425Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"23694fe3f487435eb9f4ba29fd4ca8cc","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":1,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:14:59.245Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9158d089bdb743b48614818d02d651ad","solicitation_number":"1240LR27Q0002"}]},{"notice_id":"f4f30b194c4647159c676c5005dfba09","title":"ANF Duchesne Bunkhouse AC Replacement","solicitation_number":"1240LR27Q0002","notice_type":"k","base_type":"k","posted":"2026-11-10","posted_at":"2026-11-11T00:22:33.936Z","due_at":"2026-11-20T22:00:00Z","due_date":"2026-11-20","cancelled":false,"archived":false,"archive_date":"2026-12-05","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f4f30b194c4647159c676c5005dfba09/view","enriched":true,"history":[{"index":4,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:22:33.936Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f4f30b194c4647159c676c5005dfba09","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":3,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:19:38.881Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c1e3f30708f747a886893171015df7ae","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":2,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T22:23:52.425Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"23694fe3f487435eb9f4ba29fd4ca8cc","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":1,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:14:59.245Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9158d089bdb743b48614818d02d651ad","solicitation_number":"1240LR27Q0002"}]}],"latest_notice_id":"f4f30b194c4647159c676c5005dfba09","first_type":"k","notices":[{"dates":{"posted":"2026-10-29","posted_at":"2026-10-29T22:14:59.245Z","created_at":"2026-10-29T22:04:25.810Z","modified_at":"2026-10-29T22:14:59.251Z","response_deadline":{"raw":"2026-11-13T15:00:00-07:00","utc":"2026-11-13T22:00:00Z","date":"2026-11-13","time":"15:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9158d089bdb743b48614818d02d651ad/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"ANF Duchesne Bunkhouse AC Replacement","agency":{"office":{"code":"1240LR","name":"USDA-FS, CSA INTERMOUNTAIN 6"},"subtier":{"code":"12C2","name":"FOREST SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"844012310","city":"Ogden","state":"UT","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-28","archive_type":"auto15"},"history":[{"index":1,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:14:59.245Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9158d089bdb743b48614818d02d651ad","solicitation_number":"1240LR27Q0002"}],"contacts":[{"name":"Adam Koepke","role":"primary","email":"adam.koepke@usda.gov","phone":"2087128218"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"9158d089bdb743b48614818d02d651ad","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9158d089bdb743b48614818d02d651ad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-30T04:13:40.300707258Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"346563e2cd0aba3a3bf68ea375840d6fbaf3aa1fd97c3a320e9a0bb85b2b9676","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-06T04:42:59.950874882Z","first_seen_at":"2026-10-30T03:37:02.893800920Z"},"description":{"html":"<p>This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12.&nbsp; This announcement constitutes the only solicitation.&nbsp; Quotatuions are being requested and a separate written solicitation will not be issued.&nbsp;</p>\n\n<p>Solicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :</p>\n\n<p>BASE BID &ndash; The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:</p>\n\n<p>&bull; Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.<br />\n&bull; Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.<br />\n&bull; Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.<br />\n&bull; Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.<br />\n&bull; Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.<br />\n&bull; Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.<br />\n&bull; Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.<br />\n&bull; Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.</p>\n\n<p>All work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.</p>\n\n<p>This acquisition is set-aside for small business concerns.&nbsp; The applicable North American Industry Classification Standard Code is 238220.&nbsp; The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside.&nbsp; All responsible sources may submit a quotation which will be considered by the agency.&nbsp;</p>","text":"This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotatuions are being requested and a separate written solicitation will not be issued.\n\nSolicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :\n\nBASE BID – The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:\n\n• Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.\n\n• Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.\n\n• Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.\n\n• Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.\n\n• Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.\n\n• Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.\n\n• Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.\n\n• Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.\n\nAll work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.\n\nThis acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220. The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"1240LR27Q0002","place_of_performance":{"zip":"84078","state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J041"},{"dates":{"posted":"2026-11-03","posted_at":"2026-11-03T22:23:52.425Z","created_at":"2026-11-03T22:22:41.026Z","modified_at":"2026-11-11T00:19:38.881Z","response_deadline":{"raw":"2026-11-13T15:00:00-07:00","utc":"2026-11-13T22:00:00Z","date":"2026-11-13","time":"15:00:00","timezone":"America/Denver","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/23694fe3f487435eb9f4ba29fd4ca8cc/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"ANF Duchesne Bunkhouse AC Replacement","agency":{"office":{"code":"1240LR","name":"USDA-FS, CSA INTERMOUNTAIN 6"},"subtier":{"code":"12C2","name":"FOREST SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"844012310","city":"Ogden","state":"UT","country":"USA"},"organization_id":"500169650","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-28","archive_type":"auto15"},"history":[{"index":4,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:22:33.936Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f4f30b194c4647159c676c5005dfba09","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":3,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:19:38.881Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c1e3f30708f747a886893171015df7ae","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":2,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T22:23:52.425Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"23694fe3f487435eb9f4ba29fd4ca8cc","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":1,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:14:59.245Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9158d089bdb743b48614818d02d651ad","solicitation_number":"1240LR27Q0002"}],"contacts":[{"name":"Adam Koepke","role":"primary","email":"adam.koepke@usda.gov","phone":"2087128218"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"23694fe3f487435eb9f4ba29fd4ca8cc","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9158d089bdb743b48614818d02d651ad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T10:19:19.014918938Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"a45c5457667c44920ee9084ca280d260-27\"","fetched_at":"2026-11-06T04:42:59.950874882Z","row_sha256":"8f34585219057817a42a39c92fc6378a4979f3569ba50ccc80a9121af82e3c64","last_modified":"2026-11-06T04:30:50Z"},"updated_at":"2026-11-11T10:19:19.014918938Z","first_seen_at":"2026-11-04T05:10:28.855326963Z"},"description":{"html":"<p>****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.****<br />\n<br />\nThis is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12.&nbsp; This announcement constitutes the only solicitation.&nbsp; Quotatuions are being requested and a separate written solicitation will not be issued.&nbsp;</p>\n\n<p>Solicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :</p>\n\n<p>BASE BID &ndash; The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:</p>\n\n<p>&bull; Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.<br />\n&bull; Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.<br />\n&bull; Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.<br />\n&bull; Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.<br />\n&bull; Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.<br />\n&bull; Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.<br />\n&bull; Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.<br />\n&bull; Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.</p>\n\n<p>All work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.</p>\n\n<p>This acquisition is set-aside for small business concerns.&nbsp; The applicable North American Industry Classification Standard Code is 238220.&nbsp; The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside.&nbsp; All responsible sources may submit a quotation which will be considered by the agency.&nbsp;</p>","text":"****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.****\n\nThis is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotatuions are being requested and a separate written solicitation will not be issued.\n\nSolicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :\n\nBASE BID – The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:\n\n• Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.\n\n• Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.\n\n• Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.\n\n• Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.\n\n• Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.\n\n• Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.\n\n• Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.\n\n• Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.\n\nAll work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.\n\nThis acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220. The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"1240LR27Q0002","place_of_performance":{"zip":"84078","state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J041"},{"dates":{"posted":"2026-11-10","posted_at":"2026-11-11T00:19:38.881Z","created_at":"2026-11-10T23:59:54.474Z","modified_at":"2026-11-11T00:22:33.936Z","response_deadline":{"raw":"2026-11-20T15:00:00-07:00","utc":"2026-11-20T22:00:00Z","date":"2026-11-20","time":"15:00:00","timezone":"America/Denver","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c1e3f30708f747a886893171015df7ae/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"ANF Duchesne Bunkhouse AC Replacement","agency":{"office":{"code":"1240LR","name":"USDA-FS, CSA INTERMOUNTAIN 6"},"subtier":{"code":"12C2","name":"FOREST SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"844012310","city":"Ogden","state":"UT","country":"USA"},"organization_id":"500169650","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-05","archive_type":"auto15"},"history":[{"index":4,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:22:33.936Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f4f30b194c4647159c676c5005dfba09","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":3,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:19:38.881Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c1e3f30708f747a886893171015df7ae","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":2,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T22:23:52.425Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"23694fe3f487435eb9f4ba29fd4ca8cc","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":1,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:14:59.245Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9158d089bdb743b48614818d02d651ad","solicitation_number":"1240LR27Q0002"}],"contacts":[{"name":"Adam Koepke","role":"primary","email":"adam.koepke@usda.gov","phone":"2087128218"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"c1e3f30708f747a886893171015df7ae","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9158d089bdb743b48614818d02d651ad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T11:27:10.659395034Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"0257206118ebe9482b80da2b24f1e441-27\"","fetched_at":"2026-11-11T04:50:18.941800608Z","row_sha256":"e40f70dba0306c4b38f30173299d8cac014a4546ad7832025fd4f135d5cc4691","last_modified":"2026-11-11T04:30:18Z"},"updated_at":"2026-11-11T11:27:10.659395034Z","first_seen_at":"2026-11-11T04:50:18.941800608Z"},"description":{"html":"<p>Amendment 0001 posted</p>\n\n<p>Summary of Changes:</p>\n\n<ol>\n\t<li>Terms &amp; Conditions\n\t<ol>\n\t\t<li>Added bullet 8 for attachments\n\t\t<ol>\n\t\t\t<li>C04 Attachment 9 &ndash; Q&amp;A&rsquo;s and Pictures</li>\n\t\t</ol>\n\t\t</li>\n\t\t<li>Disregard questions as we are past the due date for all main questions</li>\n\t\t<li>Solicitation closing extended to November 20th, 2026 with offers due by 1500hrs MST</li>\n\t</ol>\n\t</li>\n\t<li>Attachment 9 &ndash; Q&amp;A\n\t<ol>\n\t\t<li>Question and Answers from site visits and email submissions received by vendors.</li>\n\t</ol>\n\t</li>\n\t<li>Statement of Work\n\t<ol>\n\t\t<li>Added , 454B or R32 GWP refrigerants are also acceptable to Refrigerant requirements</li>\n\t\t<li>Updates to verbiage/requirements and information based on site visits</li>\n\t\t<li>Added Duchesne Bunkhouse floor plan and work notes, see page 20</li>\n\t</ol>\n\t</li>\n\t<li>Schedule of Items\n\t<ol>\n\t\t<li>Adjusted to show correct solicitation #: 1240LR27Q0002</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p><br />\n<br />\n****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.****<br />\n<br />\nThis is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12.&nbsp; This announcement constitutes the only solicitation.&nbsp; Quotatuions are being requested and a separate written solicitation will not be issued.&nbsp;</p>\n\n<p>Solicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :</p>\n\n<p>BASE BID &ndash; The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:</p>\n\n<p>&bull; Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.<br />\n&bull; Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.<br />\n&bull; Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.<br />\n&bull; Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.<br />\n&bull; Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.<br />\n&bull; Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.<br />\n&bull; Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.<br />\n&bull; Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.</p>\n\n<p>All work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.</p>\n\n<p>This acquisition is set-aside for small business concerns.&nbsp; The applicable North American Industry Classification Standard Code is 238220.&nbsp; The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside.&nbsp; All responsible sources may submit a quotation which will be considered by the agency.&nbsp;</p>","text":"Amendment 0001 posted\n\nSummary of Changes:\n\n• Terms & Conditions\n\n• Added bullet 8 for attachments\n\n• C04 Attachment 9 – Q&A’s and Pictures\n\n• Disregard questions as we are past the due date for all main questions\n\n• Solicitation closing extended to November 20th, 2026 with offers due by 1500hrs MST\n\n• Attachment 9 – Q&A\n\n• Question and Answers from site visits and email submissions received by vendors.\n\n• Statement of Work\n\n• Added , 454B or R32 GWP refrigerants are also acceptable to Refrigerant requirements\n\n• Updates to verbiage/requirements and information based on site visits\n\n• Added Duchesne Bunkhouse floor plan and work notes, see page 20\n\n• Schedule of Items\n\n• Adjusted to show correct solicitation #: 1240LR27Q0002\n\n****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.****\n\nThis is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotatuions are being requested and a separate written solicitation will not be issued.\n\nSolicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :\n\nBASE BID – The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:\n\n• Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.\n\n• Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.\n\n• Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.\n\n• Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.\n\n• Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.\n\n• Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.\n\n• Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.\n\n• Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.\n\nAll work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.\n\nThis acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220. The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"1240LR27Q0002","place_of_performance":{"zip":"84078","state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J041"},{"dates":{"posted":"2026-11-10","posted_at":"2026-11-11T00:22:33.936Z","created_at":"2026-11-11T00:21:26.284Z","modified_at":"2026-11-11T00:22:33.938Z","response_deadline":{"raw":"2026-11-20T15:00:00-07:00","utc":"2026-11-20T22:00:00Z","date":"2026-11-20","time":"15:00:00","timezone":"America/Denver","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f4f30b194c4647159c676c5005dfba09/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"ANF Duchesne Bunkhouse AC Replacement","agency":{"office":{"code":"1240LR","name":"USDA-FS, CSA INTERMOUNTAIN 6"},"subtier":{"code":"12C2","name":"FOREST SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"844012310","city":"Ogden","state":"UT","country":"USA"},"organization_id":"500169650","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-12-05","archive_type":"auto15"},"history":[{"index":4,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:22:33.936Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"f4f30b194c4647159c676c5005dfba09","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":3,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-11T00:19:38.881Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"c1e3f30708f747a886893171015df7ae","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":2,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-11-03T22:23:52.425Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"modify","opportunity_id":"23694fe3f487435eb9f4ba29fd4ca8cc","solicitation_number":"1240LR27Q0002","parent_opportunity_id":"9158d089bdb743b48614818d02d651ad"},{"index":1,"title":"ANF Duchesne Bunkhouse AC Replacement","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:14:59.245Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"9158d089bdb743b48614818d02d651ad","solicitation_number":"1240LR27Q0002"}],"contacts":[{"name":"Adam Koepke","role":"primary","email":"adam.koepke@usda.gov","phone":"2087128218"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"f4f30b194c4647159c676c5005dfba09","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"9158d089bdb743b48614818d02d651ad","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-11-11T12:13:17.647557695Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"0257206118ebe9482b80da2b24f1e441-27\"","fetched_at":"2026-11-11T04:50:18.941800608Z","row_sha256":"81498a18ac29998bae07ddc700a9e586476b4435b0d0e43915bf07dd5f27c385","last_modified":"2026-11-11T04:30:18Z"},"updated_at":"2026-11-11T12:13:17.647557695Z","first_seen_at":"2026-11-11T04:50:18.941800608Z"},"description":{"html":"<p>Amendment 0001 posted</p>\n\n<p>Summary of Changes:</p>\n\n<ol>\n\t<li>Terms &amp; Conditions\n\t<ol>\n\t\t<li>Added bullet 8 for attachments\n\t\t<ol>\n\t\t\t<li>C04 Attachment 9 &ndash; Q&amp;A&rsquo;s and Pictures</li>\n\t\t</ol>\n\t\t</li>\n\t\t<li>Disregard questions as we are past the due date for all main questions</li>\n\t\t<li>Solicitation closing extended to November 20th, 2026 with offers due by 1500hrs MST</li>\n\t</ol>\n\t</li>\n\t<li>Attachment 9 &ndash; Q&amp;A\n\t<ol>\n\t\t<li>Question and Answers from site visits and email submissions received by vendors.</li>\n\t</ol>\n\t</li>\n\t<li>Statement of Work\n\t<ol>\n\t\t<li>Added , 454B or R32 GWP refrigerants are also acceptable to Refrigerant requirements</li>\n\t\t<li>Updates to verbiage/requirements and information based on site visits</li>\n\t\t<li>Added Duchesne Bunkhouse floor plan and work notes, see page 20</li>\n\t</ol>\n\t</li>\n\t<li>Schedule of Items\n\t<ol>\n\t\t<li>Adjusted to show correct solicitation #: 1240LR27Q0002</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p><br />\n<br />\n****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.****<br />\n<br />\nThis is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12.&nbsp; This announcement constitutes the only solicitation.&nbsp; Quotatuions are being requested and a separate written solicitation will not be issued.&nbsp;</p>\n\n<p>Solicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :</p>\n\n<p>BASE BID &ndash; The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:</p>\n\n<p>&bull; Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.<br />\n&bull; Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.<br />\n&bull; Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.<br />\n&bull; Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.<br />\n&bull; Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.<br />\n&bull; Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.<br />\n&bull; Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.<br />\n&bull; Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.</p>\n\n<p>All work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.</p>\n\n<p>This acquisition is set-aside for small business concerns.&nbsp; The applicable North American Industry Classification Standard Code is 238220.&nbsp; The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside.&nbsp; All responsible sources may submit a quotation which will be considered by the agency.&nbsp;</p>","text":"Amendment 0001 posted\n\nSummary of Changes:\n\n• Terms & Conditions\n\n• Added bullet 8 for attachments\n\n• C04 Attachment 9 – Q&A’s and Pictures\n\n• Disregard questions as we are past the due date for all main questions\n\n• Solicitation closing extended to November 20th, 2026 with offers due by 1500hrs MST\n\n• Attachment 9 – Q&A\n\n• Question and Answers from site visits and email submissions received by vendors.\n\n• Statement of Work\n\n• Added , 454B or R32 GWP refrigerants are also acceptable to Refrigerant requirements\n\n• Updates to verbiage/requirements and information based on site visits\n\n• Added Duchesne Bunkhouse floor plan and work notes, see page 20\n\n• Schedule of Items\n\n• Adjusted to show correct solicitation #: 1240LR27Q0002\n\n****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.****\n\nThis is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotatuions are being requested and a separate written solicitation will not be issued.\n\nSolicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :\n\nBASE BID – The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:\n\n• Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.\n\n• Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.\n\n• Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.\n\n• Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.\n\n• Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.\n\n• Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.\n\n• Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.\n\n• Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.\n\nAll work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.\n\nThis acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220. The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"1240LR27Q0002","place_of_performance":{"zip":"84078","state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J041"}],"due_at":"2026-11-20T22:00:00Z","due_date":"2026-11-20","closes_at":"2026-11-20T22:00:00Z","awardable":true,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1240LR","office_name":"USDA-FS, CSA INTERMOUNTAIN 6","state":"UT","county":"49047","county_name":"Uintah County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-11-11T04:53:52.348876Z","principal_notice_id":"f4f30b194c4647159c676c5005dfba09","description":{"text":"Amendment 0001 posted\n\nSummary of Changes:\n\n• Terms & Conditions\n\n• Added bullet 8 for attachments\n\n• C04 Attachment 9 – Q&A’s and Pictures\n\n• Disregard questions as we are past the due date for all main questions\n\n• Solicitation closing extended to November 20th, 2026 with offers due by 1500hrs MST\n\n• Attachment 9 – Q&A\n\n• Question and Answers from site visits and email submissions received by vendors.\n\n• Statement of Work\n\n• Added , 454B or R32 GWP refrigerants are also acceptable to Refrigerant requirements\n\n• Updates to verbiage/requirements and information based on site visits\n\n• Added Duchesne Bunkhouse floor plan and work notes, see page 20\n\n• Schedule of Items\n\n• Adjusted to show correct solicitation #: 1240LR27Q0002\n\n****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.****\n\nThis is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12. This announcement constitutes the only solicitation. Quotatuions are being requested and a separate written solicitation will not be issued.\n\nSolicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :\n\nBASE BID – The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:\n\n• Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.\n\n• Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.\n\n• Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.\n\n• Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.\n\n• Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.\n\n• Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.\n\n• Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.\n\n• Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.\n\nAll work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.\n\nThis acquisition is set-aside for small business concerns. The applicable North American Industry Classification Standard Code is 238220. The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside. All responsible sources may submit a quotation which will be considered by the agency.","html":"<p>Amendment 0001 posted</p>\n\n<p>Summary of Changes:</p>\n\n<ol>\n\t<li>Terms &amp; Conditions\n\t<ol>\n\t\t<li>Added bullet 8 for attachments\n\t\t<ol>\n\t\t\t<li>C04 Attachment 9 &ndash; Q&amp;A&rsquo;s and Pictures</li>\n\t\t</ol>\n\t\t</li>\n\t\t<li>Disregard questions as we are past the due date for all main questions</li>\n\t\t<li>Solicitation closing extended to November 20th, 2026 with offers due by 1500hrs MST</li>\n\t</ol>\n\t</li>\n\t<li>Attachment 9 &ndash; Q&amp;A\n\t<ol>\n\t\t<li>Question and Answers from site visits and email submissions received by vendors.</li>\n\t</ol>\n\t</li>\n\t<li>Statement of Work\n\t<ol>\n\t\t<li>Added , 454B or R32 GWP refrigerants are also acceptable to Refrigerant requirements</li>\n\t\t<li>Updates to verbiage/requirements and information based on site visits</li>\n\t\t<li>Added Duchesne Bunkhouse floor plan and work notes, see page 20</li>\n\t</ol>\n\t</li>\n\t<li>Schedule of Items\n\t<ol>\n\t\t<li>Adjusted to show correct solicitation #: 1240LR27Q0002</li>\n\t</ol>\n\t</li>\n</ol>\n\n<p><br />\n<br />\n****As a heads up we will be issuing an amendment for this solicitation prior to the current due date for quotes listed in the current solicitation. We will be extending the due date which will be listed in the amendment forthcoming. If you already submitted please resubmit an updated quote after the amendment has been sent out so that you can review the updates and sign the amendment form (SF30) and return it with your quote.****<br />\n<br />\nThis is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Part 12.&nbsp; This announcement constitutes the only solicitation.&nbsp; Quotatuions are being requested and a separate written solicitation will not be issued.&nbsp;</p>\n\n<p>Solicitation number1240LR27Q0002 is issued as a Requst for Quotation (RFQ) for :</p>\n\n<p>BASE BID &ndash; The work under this contract includes furnishing all labor, materials, equipment, tools, transportation, and incidentals necessary to remove the existing 5‑ton air‑cooled refrigerant condenser unit and associated indoor coil, and to provide and install a new 2.5‑ton air‑cooled condenser unit and compatible indoor coil at the Duchesne Bunkhouse. Work shall include, but is not limited to:</p>\n\n<p>&bull; Disconnecting, recovering, and properly disposing of all refrigerant in accordance with federal and state environmental regulations.<br />\n&bull; Disconnecting and removing the existing condenser, indoor coil, associated piping, electrical connections, mounting hardware, and any other components required for a complete system removal.<br />\n&bull; Providing and installing the new 2.5‑ton condenser and coil, including all refrigerant piping, line sets, insulation, fittings, mounting pads, vibration isolation, and supports as required.<br />\n&bull; Making all necessary electrical modifications, including reconnection to existing circuits, installation of new disconnects or breakers if required, and ensuring code‑compliant grounding and bonding.<br />\n&bull; Pressure‑testing, evacuating, and charging the new system with the appropriate refrigerant type and quantity, following manufacturer specifications.<br />\n&bull; Verifying proper airflow, condensate drainage, thermostat compatibility, and control wiring to ensure a fully functional and balanced system.<br />\n&bull; Performing system start‑up, testing, and commissioning to confirm proper operation and to meet manufacturer performance standards.<br />\n&bull; Restoring and/or repairing all surfaces, penetrations, and finishes affected by the work, leaving the site in clean and workmanlike condition.</p>\n\n<p>All work shall be completed in accordance with applicable codes, manufacturer instructions, and agency standards to provide a fully operational and complete HVAC system.</p>\n\n<p>This acquisition is set-aside for small business concerns.&nbsp; The applicable North American Industry Classification Standard Code is 238220.&nbsp; The small business size standard is $19 Million. This acquisition is a Total Small Business Set-Aside.&nbsp; All responsible sources may submit a quotation which will be considered by the agency.&nbsp;</p>","origin":"detail"},"contacts":[{"name":"Adam Koepke","role":"primary","email":"adam.koepke@usda.gov","phone":"2087128218"}],"place_of_performance":{"zip":"84078","state":{"code":"UT","name":"Utah"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"844012310","city":"Ogden","state":"UT","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"8e90979924244967990fafcee9d44d88","name":"C04 1240LR27Q0002.pdf","kind":"file","mime_type":".pdf","size_bytes":141335,"posted_at":"2026-10-29T22:14:59.245Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8e90979924244967990fafcee9d44d88/download","mirrored":false},{"resource_id":"5b248ddc89a74e92b4c42da17cf4673e","name":"C04 Attachment 4 - Past Performance Data Sheet.pdf","kind":"file","mime_type":".pdf","size_bytes":336052,"posted_at":"2026-10-29T22:14:59.245Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5b248ddc89a74e92b4c42da17cf4673e/download","mirrored":false},{"resource_id":"5363c983aa874ec8a937d99bcbd84530","name":"C04 Attachment 7 - Equipment List.pdf","kind":"file","mime_type":".pdf","size_bytes":381317,"posted_at":"2026-10-29T22:14:59.245Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/5363c983aa874ec8a937d99bcbd84530/download","mirrored":false},{"resource_id":"8e8ce3bf51774f34812f7835309f708d","name":"C04 Attachment 6 - Biobased Product List.pdf","kind":"file","mime_type":".pdf","size_bytes":402234,"posted_at":"2026-10-29T22:14:59.245Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/8e8ce3bf51774f34812f7835309f708d/download","mirrored":false},{"resource_id":"b47298f52e5041bdb64df491cd78b8e2","name":"C04 Attachment 3 - Wage Determination.pdf","kind":"file","mime_type":".pdf","size_bytes":680126,"posted_at":"2026-10-29T22:14:59.245Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/b47298f52e5041bdb64df491cd78b8e2/download","mirrored":false},{"resource_id":"63972c66fcb145399fa4604dbff9ecc7","name":"C04 Attachment 5 - Team Partner Consent Form.pdf","kind":"file","mime_type":".pdf","size_bytes":721401,"posted_at":"2026-10-29T22:14:59.245Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/63972c66fcb145399fa4604dbff9ecc7/download","mirrored":false},{"resource_id":"ea59160d44a644949c441909c540c266","name":"C05 1240LR27Q0002 SF30 Amendment 0001.pdf","kind":"file","mime_type":".pdf","size_bytes":83998,"posted_at":"2026-11-11T00:19:38.881Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ea59160d44a644949c441909c540c266/download","mirrored":false},{"resource_id":"ea859944f82b40f894932dfd34e58402","name":"Summary of Changes.pdf","kind":"file","mime_type":".pdf","size_bytes":99758,"posted_at":"2026-11-11T00:19:38.881Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ea859944f82b40f894932dfd34e58402/download","mirrored":false},{"resource_id":"ad2ff5d14998430eb73096e568f17734","name":"C05 Attachment 8 - Schedule of Items.pdf","kind":"file","mime_type":".pdf","size_bytes":176090,"posted_at":"2026-11-11T00:19:38.881Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/ad2ff5d14998430eb73096e568f17734/download","mirrored":false},{"resource_id":"9537f69560de4ec0aa5c9c883c3cdc54","name":"C05 Attachment 2 - Statement of Work.pdf","kind":"file","mime_type":".pdf","size_bytes":306551,"posted_at":"2026-11-11T00:19:38.881Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/9537f69560de4ec0aa5c9c883c3cdc54/download","mirrored":false},{"resource_id":"60ac100118514a00ad62f6e7f75b8c64","name":"C05 Attachment 1 - Solicitation Terms and Conditions Revised.pdf","kind":"file","mime_type":".pdf","size_bytes":316644,"posted_at":"2026-11-11T00:19:38.881Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/60ac100118514a00ad62f6e7f75b8c64/download","mirrored":false},{"resource_id":"35742b6710cf4c67815484014058d8d0","name":"C05 Attachment 9 - Q andA.pdf","kind":"file","mime_type":".pdf","size_bytes":3720713,"posted_at":"2026-11-11T00:22:33.936Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/35742b6710cf4c67815484014058d8d0/download","mirrored":false}],"awards":[],"related":[],"similar_open":[{"key":"W911PT27QA020","latest_notice_id":"084d5efc5ec44a9885a37b90e6705ffa","title":"REMOVE AND REPAIR TWO HIGH VELOCITY AIR HANDLING UNITS","solicitation_number":"W911PT27QA020","notice_type":"k","first_type":"k","first_posted":"2026-11-05","last_posted":"2026-11-05","notices":1,"due_at":"2026-11-25T18:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911PT","office_name":"W6QK ACC WVA","naics":"238220","psc":"Z2NB","set_aside":"SBA","state":"NY","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"description","state_evidence":"IGH VELOCITY AIR HANDLING UNITSPROJECT LOCATION: WATERVLIET ARSENAL","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"},{"key":"2031ZA27B00001","latest_notice_id":"622efd27a6cf48589063c08d3700b96b","title":"Modernize Regenerative Thermal Oxidizer (RTO)","solicitation_number":"2031ZA27B00001","notice_type":"r","first_type":"r","first_posted":"2026-11-18","last_posted":"2026-11-18","notices":1,"due_at":"2026-11-25T21:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T21:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-020","dept_name":"TREASURY, DEPARTMENT OF THE","sub_key":"s-2041","sub_name":"BUREAU OF ENGRAVING AND PRINTING","office_key":"o-2031ZA","office_name":"OFFICE OF THE CHIEF PROCUREMENT OFFICER","naics":"238220","psc":"Z2AZ","set_aside":null,"state":"TX","county":"48439","county_name":"Tarrant County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-19T04:41:36.780616Z"},{"key":"140PP027B0004","latest_notice_id":"53398cb59b8f4b0687efd4e3fa6241dc","title":"Z--13976 PUHO FIRE PROTECTION AT DORM","solicitation_number":"140PP027B0004","notice_type":"r","first_type":"s","first_posted":"2026-11-19","last_posted":"2026-11-19","notices":2,"due_at":"2026-11-26T03:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-26T03:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-014","dept_name":"INTERIOR, DEPARTMENT OF THE","sub_key":"s-1406","sub_name":"DEPARTMENTAL OFFICES","office_key":"o-140PP0","office_name":"NATIONAL PARK SERVICE CONTRACTING ACTIVITY","naics":"238220","psc":"Z2AA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-20T05:30:09.595354Z"}],"similar_open_total":59,"indexable":true}