{"canonical":"https://sealedbidder.com/opportunities/1240bj26q0046","key":"1240BJ26Q0046","url":"https://sealedbidder.com/opportunities/1240bj26q0046","title":"Three Rivers RS Bldg# 2017 HVAC Replacement","solicitation_number":"1240BJ26Q0046","notice_type":"p","open":false,"removed":false,"removed_at":null,"response_deadline":null,"first_posted":"2026-08-12","last_posted":"2026-08-12","department":"AGRICULTURE, DEPARTMENT OF","subagency":"FOREST SERVICE","office":"USDA FOREST SERVICE","naics":"238220","psc":"J045","set_aside":"SBA","place_state":"WA","place_scope":"site","site":null,"place_state_source":null,"place_evidence":null,"place_county":"53065","place_county_name":"Stevens County","place_city":"5335485","place_city_name":"Kettle Falls","winner":"DIVCO INC","award_amount":null,"publications":[{"notice_id":"4d0b0356903b4c369e4af47f4fccc85f","title":"Three Rivers RS Bldg# 2017 HVAC Replacement","solicitation_number":"1240BJ26Q0046","notice_type":"p","base_type":"p","posted":"2026-08-12","posted_at":"2026-08-12T20:14:30.944Z","due_at":null,"due_date":null,"cancelled":false,"archived":true,"archive_date":"2026-09-15","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4d0b0356903b4c369e4af47f4fccc85f/view","enriched":true,"history":[{"index":3,"title":"Three Rivers RS Bldg# 2017 HVAC Replacement","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-12T20:14:30.944Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4d0b0356903b4c369e4af47f4fccc85f","solicitation_number":"1240BJ26Q0046"}]}],"latest_notice_id":"4d0b0356903b4c369e4af47f4fccc85f","first_type":"p","notices":[{"dates":{"posted":"2026-08-12","posted_at":"2026-08-12T20:14:30.944Z","created_at":"2026-08-12T20:07:02.335Z","modified_at":"2026-09-15T05:07:31.448Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/4d0b0356903b4c369e4af47f4fccc85f/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Three Rivers RS Bldg# 2017 HVAC Replacement","agency":{"office":{"code":"1204U3","name":"USDA FOREST SERVICE"},"subtier":{"code":"12C2","name":"FOREST SERVICE"},"department":{"code":"012","name":"AGRICULTURE, DEPARTMENT OF"},"office_address":{"zip":"97601","city":"KLAMATH FALLS","state":"OR","country":"USA"},"organization_id":"100162176","organization_type":"OFFICE"},"status":{"active":false,"latest":true,"deleted":false,"archived":true,"cancelled":false,"publication":"published","archive_date":"2026-09-15","archive_type":"auto_custom"},"history":[{"index":3,"title":"Three Rivers RS Bldg# 2017 HVAC Replacement","action":"publish","latest":true,"deleted":false,"archived":true,"cancelled":false,"posted_at":"2026-08-12T20:14:30.944Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"4d0b0356903b4c369e4af47f4fccc85f","solicitation_number":"1240BJ26Q0046"}],"contacts":[{"name":"Eric Oldenkamp","role":"primary","email":"eric.oldenkamp@usda.gov"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"4d0b0356903b4c369e4af47f4fccc85f","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"lineage_id":"4d0b0356903b4c369e4af47f4fccc85f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-09-25T01:29:01.068983252Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"1571ce30698fe7b740fc98b2cfaecbac-30\"","fetched_at":"2026-09-16T00:55:28.845070Z","row_sha256":"a5e1b3fe230cd576f6d45287364f2e8fe9fcf94b07ade8942955faaa88e6efd7","last_modified":"2026-09-15T03:30:54Z"},"updated_at":"2026-09-25T01:29:01.068983252Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"html":"<p>This project consists of removing existing electric single packaged vertical unit (SPVU) and legally dispose. Provide and install similar new electric 4-ton SPVU (minimum 11 EER/3.3 COP) with defrost kit [Bard W48HFA15 and Bard HVAC 8620-223 Defrost Board Replacement Kit or approved equals], including all electrical (with any necessary connections or upgrades to the panel), structural or ducting modifications, and non-proprietary, programmable control(s). Perform startup testing and adjustments. Provide O&amp;M manual(s), including as-built drawings. Obtain all appropriate permits necessary to complete the project. Clean all existing air ductwork (interior surfaces) and registers with HEPA filtrated vacuum device(s) and legally dispose of waste. &nbsp;Disconnect flexible ducting for cleaning and inspection, then reconnect properly and inspect when the system is running.</p>\n\n<p>Project Location: Three Rivers Ranger Station (Bldg #2017) 255 W 11th Ave, Kettle Falls, WA 99141</p>\n\n<p>This project is being solicited in accordance with FAR 12.201-1(c)(2).&nbsp; The Government will issue a request for quotes directly from local HVAC contractors, and will not issue a solicitation on SAM.gov.&nbsp; If your company is interested in future small HVAC projects in eastern Washington, then ensure that you have an active SAM.gov account and provide your company name and Unique Entity Identifier (UEI Number) to eric.oldenkamp@usda.gov.</p>","text":"This project consists of removing existing electric single packaged vertical unit (SPVU) and legally dispose. Provide and install similar new electric 4-ton SPVU (minimum 11 EER/3.3 COP) with defrost kit [Bard W48HFA15 and Bard HVAC 8620-223 Defrost Board Replacement Kit or approved equals], including all electrical (with any necessary connections or upgrades to the panel), structural or ducting modifications, and non-proprietary, programmable control(s). Perform startup testing and adjustments. Provide O&M manual(s), including as-built drawings. Obtain all appropriate permits necessary to complete the project. Clean all existing air ductwork (interior surfaces) and registers with HEPA filtrated vacuum device(s) and legally dispose of waste. Disconnect flexible ducting for cleaning and inspection, then reconnect properly and inspect when the system is running.\n\nProject Location: Three Rivers Ranger Station (Bldg #2017) 255 W 11th Ave, Kettle Falls, WA 99141\n\nThis project is being solicited in accordance with FAR 12.201-1(c)(2). The Government will issue a request for quotes directly from local HVAC contractors, and will not issue a solicitation on SAM.gov. If your company is interested in future small HVAC projects in eastern Washington, then ensure that you have an active SAM.gov account and provide your company name and Unique Entity Identifier (UEI Number) to eric.oldenkamp@usda.gov.","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"1240BJ26Q0046","place_of_performance":{"city":{"code":"35485","name":"Kettle Falls"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"J045"}],"due_at":null,"due_date":null,"closes_at":null,"awardable":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1204U3","office_name":"USDA FOREST SERVICE","state":"WA","county":"53065","county_name":"Stevens County","city":"5335485","city_name":"Kettle Falls","country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":"EEYZZTKW9NT6","amount":null,"linked_awards":1,"cancelled":false,"archived":true,"updated_at":"2026-10-02T06:21:37.547001Z","principal_notice_id":"4d0b0356903b4c369e4af47f4fccc85f","description":{"text":"This project consists of removing existing electric single packaged vertical unit (SPVU) and legally dispose. Provide and install similar new electric 4-ton SPVU (minimum 11 EER/3.3 COP) with defrost kit [Bard W48HFA15 and Bard HVAC 8620-223 Defrost Board Replacement Kit or approved equals], including all electrical (with any necessary connections or upgrades to the panel), structural or ducting modifications, and non-proprietary, programmable control(s). Perform startup testing and adjustments. Provide O&M manual(s), including as-built drawings. Obtain all appropriate permits necessary to complete the project. Clean all existing air ductwork (interior surfaces) and registers with HEPA filtrated vacuum device(s) and legally dispose of waste. Disconnect flexible ducting for cleaning and inspection, then reconnect properly and inspect when the system is running.\n\nProject Location: Three Rivers Ranger Station (Bldg #2017) 255 W 11th Ave, Kettle Falls, WA 99141\n\nThis project is being solicited in accordance with FAR 12.201-1(c)(2). The Government will issue a request for quotes directly from local HVAC contractors, and will not issue a solicitation on SAM.gov. If your company is interested in future small HVAC projects in eastern Washington, then ensure that you have an active SAM.gov account and provide your company name and Unique Entity Identifier (UEI Number) to eric.oldenkamp@usda.gov.","html":"<p>This project consists of removing existing electric single packaged vertical unit (SPVU) and legally dispose. Provide and install similar new electric 4-ton SPVU (minimum 11 EER/3.3 COP) with defrost kit [Bard W48HFA15 and Bard HVAC 8620-223 Defrost Board Replacement Kit or approved equals], including all electrical (with any necessary connections or upgrades to the panel), structural or ducting modifications, and non-proprietary, programmable control(s). Perform startup testing and adjustments. Provide O&amp;M manual(s), including as-built drawings. Obtain all appropriate permits necessary to complete the project. Clean all existing air ductwork (interior surfaces) and registers with HEPA filtrated vacuum device(s) and legally dispose of waste. &nbsp;Disconnect flexible ducting for cleaning and inspection, then reconnect properly and inspect when the system is running.</p>\n\n<p>Project Location: Three Rivers Ranger Station (Bldg #2017) 255 W 11th Ave, Kettle Falls, WA 99141</p>\n\n<p>This project is being solicited in accordance with FAR 12.201-1(c)(2).&nbsp; The Government will issue a request for quotes directly from local HVAC contractors, and will not issue a solicitation on SAM.gov.&nbsp; If your company is interested in future small HVAC projects in eastern Washington, then ensure that you have an active SAM.gov account and provide your company name and Unique Entity Identifier (UEI Number) to eric.oldenkamp@usda.gov.</p>","origin":"detail"},"contacts":[{"name":"Eric Oldenkamp","role":"primary","email":"eric.oldenkamp@usda.gov"}],"place_of_performance":{"city":{"code":"35485","name":"Kettle Falls"},"state":{"code":"WA","name":"Washington"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"97601","city":"KLAMATH FALLS","state":"OR","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_1240BJ26P0014_12C2_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_1240BJ26P0014_12C2_-NONE-_-NONE-/","piid":"1240BJ26P0014","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"EEYZZTKW9NT6","recipient_name":"DIVCO INC","recipient_uei":"EEYZZTKW9NT6","recipient_cage":"3CXT7","recipient_city":"SPOKANE","recipient_state":"WA","sub_name":"Forest Service","office_name":"USDA-FS, CSA NORTHWEST 7","office_key":"o-1240BJ","first_action_date":"2026-09-29","last_action_date":"2026-10-01","actions":2,"obligated":"23843.00","current_total_value":"23843.00","potential_total_value":"23843.00","naics":"238220","psc":"J045","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":2,"description":"THREE RIVERS RS BLDG# 2017 HVAC REPLACEMENT","method":"solicitation","confidence":"high","evidence":["solicitation number 1240BJ26Q0046 equals the FPDS solicitation identifier","same sub-agency 12C2"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"1240BJ27Q0006","latest_notice_id":"437677f94aab4f34a7733c8d9b90ec46","title":"Tonasket Ranger Station HVAC Replacement Building 2007","solicitation_number":"1240BJ27Q0006","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-05","notices":2,"due_at":"2026-12-04T01:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-04T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1204U3","office_name":"USDA FOREST SERVICE","naics":"238220","psc":"J045","set_aside":"SBA","state":"WA","county":"53047","county_name":"Okanogan County","city":"5371890","city_name":"Tonasket","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"}],"similar_open":[{"key":"36C26027R0021","latest_notice_id":"7a19b19c49c240a496641c5f39341d63","title":"Repair Sanitary Waste Piping at the Mann-Grandstaff VA Medical Center","solicitation_number":"36C26027R0021","notice_type":"o","first_type":"p","first_posted":"2026-10-16","last_posted":"2026-11-24","notices":5,"due_at":"2026-12-02T17:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"238220","psc":"Z1DA","set_aside":"SDVOSBC","state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Mann-Grandstaff VA Medical Center","site_key":"mann-grandstaff-va-medical-center-wa","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-25T05:14:59.249783Z"},{"key":"36C26027R0014","latest_notice_id":"a7cf92df99704dd8a939bfddadd69228","title":"Z1DA--CON-NRM-668-22-106 Correct Domestic Water System","solicitation_number":"36C26027R0014","notice_type":"o","first_type":"o","first_posted":"2026-10-14","last_posted":"2026-11-23","notices":11,"due_at":"2026-12-03T20:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-03T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"238220","psc":"Z1DA","set_aside":"SDVOSBC","state":"WA","county":"53063","county_name":"Spokane County","city":"5367000","city_name":"Spokane","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-24T04:44:58.053639Z"},{"key":"1240BJ27Q0006","latest_notice_id":"437677f94aab4f34a7733c8d9b90ec46","title":"Tonasket Ranger Station HVAC Replacement Building 2007","solicitation_number":"1240BJ27Q0006","notice_type":"k","first_type":"k","first_posted":"2026-11-04","last_posted":"2026-11-05","notices":2,"due_at":"2026-12-04T01:00:00Z","due_date":"2026-12-03","closes_at":"2026-12-04T01:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-1204U3","office_name":"USDA FOREST SERVICE","naics":"238220","psc":"J045","set_aside":"SBA","state":"WA","county":"53047","county_name":"Okanogan County","city":"5371890","city_name":"Tonasket","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-11-06T04:46:59.158685Z"}],"similar_open_total":57,"indexable":false}