Sources sought
OCTO-FloX System
1163769
Agricultural Research Service, USDA ARS Afm Apd. Analytical Laboratory Instrument Manufacturing.
Response deadline
March 16, 2026 at 12:00 PM EDT
Closed 255 days ago. Posted March 2, 2026. Scheduled to archive March 31, 2026.
Get the next one like this from Agricultural Research Service by email, the day it is posted.Find my opportunities
This one closed in 2026
55 like it are open now in analytical laboratory instrument manufacturing
- Notice of Intent - Illumina MiSeq i100 series instruments
National Institutes of Health, National Institutes of Health - CC
PresolicitationNAICS 334516Ship to Bethesda, MDNOI-OLAO-CC-27-000836Due tomorrowNov 27 - Graphite Furnace Atomic Absorption Spectrometer
National Institute of Standards and Technology, Department of Commerce NIST
Sources soughtNAICS 334516Ship to Gaithersburg, MDNIST-MML-FY27-SS01Due in 2 daysNov 28 - Intent to Solicit Only One Source for Six (6) Twinleaf Pulsed Pump Magnetometer (part number: PPM-RS422) and one (1) Twinleaf 8 Channel Synchronization Hub (part number: HUB-RS422-8) manufactured by Twinleaf.
Department of the Army, W6QK ACC-APG Adelphi
SolicitationNAICS 334516Ship to MDW911QX27QA015Due in 5 daysDec 1
All 55 open in analytical laboratory instrument manufacturing
Reading this notice
Worked out from the publications and the award on this page.
- Kind of notice
- Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
- Who may compete
- SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
- What comes next
- No solicitation was published under this number after the sources sought of March 2, 2026. An agency sometimes issues the solicitation under a new number.
Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.
Description
As published on SAM.gov.
Requirement for a rugged, field-ready hyperspectral spectrometer capable of sufficiently high spectral resolution to acquire solar-induced chlorophyll fluorescence and sequentially measuring six or more targets. Only minor follow-on work (firmware updates) are expected. Product must be equivalent to the OCTO-FloX produced by JB Hyperspectral Devices GmbH.
Salient characteristics for Item 0001:
The following are minimum specifications and performance criteria for the unit:
• Spectral resolution fine enough to retrieve solar-induced chlorophyll fluorescence (SIF) from telluric and solar absorption features (< 1 nm FWHM).
• Wavelength range wide enough to cover 500 – 900 nm to enable simultaneous acquisition of red SIF at 687 nm; far-red SIF at 760 nm; photochemical reflectance index (PRI) at 530 nm and 570 nm; normalized difference vegetation index (NDVI) and near-infrared reflectance of vegetation (NIRv) at 650 nm and 860 nm.
• Capable of rapid acquisition across multiple (at least 6) vegetative targets in different plots or growth chambers using fixed fiber optics.
• Capable of both hemispherical-conical or bi-hemispherical configurations, adjustable by user through removable cosine correctors designed for outdoor use.
• Weatherproof (IP67 rated) to allow deployment of unit in variable outdoor environments.
• Integrated thermal regulation to maintain spectrometer temperature consistently at 20 degrees Celsius. Intelligent temperature management modes for power saving. Heatingo for cold conditions.
• System operational temperature range from -10 to 50 degrees Celsius.• Automatic optimization of integration time to maximize spectrometer dynamic range across 0-2000 PPFD.
• Correction for dark current and detector nonlinearity.
• Wavelength calibration and optimization of spectral shift.
• Radiometric calibration for both bare fiber and cosine corrected fiber configurations.
Salient characteristics for Item 0002 –
JB COS Cosine Receptor for the measurement of solar irradiance. Must be equivalent to the JB COS produced by JB Hyperspectral.
Salient Characteristics for Item 0002:
• Must be 100 percent compatible with the other item(s) described in this notice (see Item 0001).
• Cosine error of < 10% at 80 degrees
• Spectral range of 400 nm - 1000 nm
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
March 2, 2026
Sources sought
Due March 16, 2026 at 12:00 PM EDT. SAM.gov, notice 821defdf6cbe469b9a4e56d4ecff7256
1 revision on SAM
- March 2, 2026: publish, sources sought
Points of contact
- Katelyn Nelsonkatelyn.nelson@usda.gov3018378754