Sources sought

Methane Analyzer

1124832

Agricultural Research Service, USDA ARS Sea Aao Acq/Per Prop. Analytical Laboratory Instrument Manufacturing.

Response deadline

April 5, 2024 at 5:00 PM EDT

Closed 966 days ago. Posted April 2, 2024. Scheduled to archive April 20, 2024.

Get the next one like this from Agricultural Research Service by email, the day it is posted.Find my opportunities

This one closed in 2024

53 like it are open now in analytical laboratory instrument manufacturing

All 53 open in analytical laboratory instrument manufacturing

Reading this notice

Worked out from the publications and the award on this page.

Kind of notice
Sources sought. Market research. The agency wants to know who could do the work before it decides how to compete it. Glossary
Who may compete
SAM.gov lists no set-aside on this notice, so it is not reserved for small businesses. Small, under NAICS 334516 (analytical laboratory instrument manufacturing), means no more than 1,000 employees, counted with affiliates. What a set-aside is
What comes next
No solicitation was published under this number after the sources sought of April 2, 2024. An agency sometimes issues the solicitation under a new number.

Size standard from 13 CFR 121.201. The solicitation itself is what binds: check the code and standard it states.

Description

As published on SAM.gov.

The USDA ARS location at 504 University Loop Jonesboro, AR 72401 UNITED STATES is looking for a Methane Analyzer, specifically Licor LI-7700 that meets the below specifications. A Li-Cor authorized distributor is required.

This requirement will ensure that devices are not counterfeit or adulterated devices, have maintained adequate storage conditions, and any warranties and service and/or preventative maintenance agreements are transferred and will be honored by Li-Cor Biosciences Statement of work The LI-7700 analyzer is part of a system solely manufactured by LI-COR Biosciences. This sensor will measure methane production from an on-farm surface water reservoir used in agricultural production.

The LI-7700 will be added to the existing data collection network infrastructure managed by the Delta Water Management Research Unit. The LI-7700 Open Path CH? Analyzer makes in-situ measurements of methane density with the resolution, speed, and stability required for the eddy covariance technique. The light weight, low power design provides the instrument the ability to acquire methane density data necessary to characterize ecosystem methane flux in remote environments.

The open path design eliminates the need for pumps and tubing, and does not have pressure drops, tubing attenuation, or time delays associated with other closed path systems.

Standard Features: Resolution (RMS noise): 5 ppb @ 10 Hz and 2000 ppb CH4 Measurement Range: 0 to 25 ppm @ -25 °C, 0 to 40 ppm @ 25 °C Data Communication: Ethernet (up to 40 Hz)

Detection Method: Wavelength Modulation Spectroscopy 2f detection Linearity: Within 1% of reading Operating Pressure Range: 50 to 110 kPa Output Bandwidth: up to 20 Hz Operating Temperature Range: -25 to 50 °C Power Requirements:

10.5 to 30 VDC Power Consumption: 8 W nominal, 16 W during cleaning cycle Dimensions:

Sensor: 14.33 cm dia (5.64 inches), 82.8 cm height (32.6 inches)

Optical Path: 0.5 m physical path (1.65 ft), 30 m measurement path (98.4 ft)

Weight: 5.2 kg (11.5 lbs)

User Interface: Windows®based software supports all setup, configuration, and calibration functions through Ethernet connection

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. April 2, 2024

    Sources sought

    Due April 5, 2024 at 5:00 PM EDT. SAM.gov, notice 81099083c3d24681b238d53713682a5f